Loading...
07-0819 (CSCS)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-i'&t 4 4a Q” BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 07-00000819 Property Address: 79815 HIGHWAY 111 APN: 600-020-034- - - Application description: NEW COMML - STORES & CUSTOMER SERVICE Property Zoning: COMMERCIAL PARK Application valuation: 986197 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B C9 cense No.: 436418 Date.„ _ Contractor. I((Cj1 -T OWNER- UILDER DECLARATION , I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his. or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ .Lender's Address: LQPEILAIIT. Owner: KOMAR INV 23 CORPORATE PLZ STE 247 NEWPORT BEACH, CA 92660 Contractor: BERGMAN COMPANIES, THE 4300 EDISON AVENUE CHINO., CA 91710 (909)627-3651 Lic. No.: 436418 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 -------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AMERICAN INTL Policy Number WC5312540 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to b come sub' ct to the workers' compensation laws of California, and agree that, if I should eco a subjec o the the compensation provisions of Section 1�L_L/L�L3.,7iL00 of the Labor e, sh forthwit co with those provisions. Date Applicant: 6 , WARNING: FAILURE TO SECURE WORKERS' CO PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above inf anon is correct. I agree to comply with all city and co ty rdinances and state laws relating to building s uction, a hereby authorize representatives ci this co, enter upon the above-mentioned prop fo i ection pur s. Date9 fl Signature (Applicant or Agentl. Date: 8/29/07 Application Number . . . . . 07-00000819 ------ Structure Information SHELL BUILDING "A" ----- Other struct info . . . . . CODE EDITION 01BMP04E05EN FIRE SPRINKLERS YES MIXED-USE OCCUPANCY SHELL OCCUPANT LOAD .00 PATIO SQ FTG 479.00 1ST FLOOR SQUARE FOOTAGE 19931.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE .00 Permit . . . BUILDING PERMIT Additional desc 19,931 SF SHELL BLDG. A Permit Fee . . . . 3500.50 Plan Check Fee 2275.33 Issue Date . . . . Valuation . . . . 986197 Expiration Date 2/25/08 Qty Unit Charge Per Extension BASE FEE 2039.50 487.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 1461.00 Permit . . . ELEC-NEW COMMERCIAL Additional desc INCL. LIGHTG & POWER Q STE101 Permit Fee . . 423.20 Plan Check Fee 105.80 Issue Date Valuation 0 . Expiration Date 2/25/08 Qty Unit Charge Per 'Extension. BASE FEE 15.00 20410.00 .0200 ------------------------------=---------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 408.20 Permit . . . MECHANICAL Additional desc DUCTS & REGISTERS Q STE 101 Permit Fee . . . . 220.00 Plan Check Fee 55.00 ' Issue Date Valuation 0 Expiration Date 2/25/08 Qty Unit Charge. Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 ' 6.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 99.00 2:00 6.5000 EA MECH VENT FAN 13.00 6.00 6.5000 ---------------------------------------------------------------------------- EA MECH EXHAUST HOOD 39.00 Permit . . . . . . PLUMBING 0 LQPERI%IIT Application Number. . . . . . 07700000819 Permit . . . PLUMBING Additional desc . . (2) TOILET RMS C STE 101 Permit Fee . . . . 135.00 Plan Check Fee 33.75 Issue Date . . . . Valuation 0 Expiration Date 2/25/08 Qty Unit Charge Per Extension BASE FEE 15.00 6.00 6.0000 EA PLB FIXTURE 36.00 2.00 15.0000 EA PLB BUILDING SEWER 30.00 4.00 6.0000 EA PLB ROOF DRAIN 24.00 2.00 3.0000 EA PLB WATER INST/ALT/REP 6.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 2.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/25/08 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 19,931 SQ.FT. SHELL BUILDING "A", TYPE V -N CONSTRUCTION. B & M PROPOSED OCCUPANCY.FIRE SPRINKLER & 2 YARDS FOR ALLOWABLE AREA INCREASE = 8,OOOSF X 3 X 1.5=36,000SF ALLOWABLE. 2001 CBC,CMC,CPC,2004 CEC, 2005 ENERGY. **PERMIT DOES NOT INCLUDE TEMPORARY POWER,'BLOCK WALLS, TRASH ENCLOSURE.AND SITE LIGHTING.** SUITE 101 INCORPORATES LIGHTING & HVAC DUCTING. -------------'--------------------------------------------------------------- Other Fees . . . . . ACCESSIBILITY PLAN REVIEW 227.53 ART IN PUBLIC PLACES -COM 4910.98 DIF CIVIC CENTER - COMM 6417.78 ENERGY REVIEW FEE 227.53 DIF FIRE PROTECTION -COMM 896.86 STRONG MOTION (SMI) - COM 207.10 DIF STREET MAINT..FAC-COMM 2112.68 DIF TRANSPORTATION - COMM 60570.30 Fee summary Charged Paid Credited --------------------------------------------------------- Due LQPEILVIIT • Application Number . . . . . 07-00000819 . Permit Fee Total 4293.70 .00 .00 4293.70 _ Pian Check Total 2469.88 1500.00 :00 969.88 Other Fee,Total 75570.76 .00 .00 75570.76 Grand Total 82334.34 1500.00 .00 80834.34 / LQPERDIIT John R. Hawkins Fire Chief Proudly serving the Unincorporated Areas of Riverside County and the Cities of: Banning Beaumont ❖ Calimesa Canyon Lake Coachella Desert Hot Springs Indian Wells 4• Indio Lake Elsinore La Quinta 4. Moreno Valley Palm Desert Perris 41. Rancho Mirage 4• San Jacinto 4. Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 June 5, 2007 Neil Dixon SGPA Planning & Architecture 1545 Hotel Circle Suite 200 San Diego, Ca. 92108 Re: Building Plan Review KFC LAQ-07-BP-040 Komar Desert Center 79;OM Highway 111 Building A Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. 1) These conditions are for a shell building and will receive a shell final only. No fire and life safety clearance will be issued for a tenant space until the specific occupancy classification has been established and tenant improvement plans have been reviewed and conditioned by the Riverside County Fire Department. 2) Fire Department approval is based upon the 2001 CBC requirements for Group B occupancies. It is prohibited to use, process or store any materials in the occupancy that would classify it as a Group H occupancy per Sec. 307 of the 2001 CBC. 3) Repair work and/or maintenance using open flame equipment, welding or the use of Class I, II, or III -A liquids are prohibited. 4) A combination of on-site and off-site Super wet barrel fire hydrants (6" x 4" x 21/21' x 21/211), on a looped system shall be located not less than 25' or more than 165' from any portion of the buildings as measured along approved vehicular travel ways. The required fire flow shall be available from any adjacent hydrants in the system. The following conditionsmust be met prior to occupancy 5) Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire Department for review, along with a plan/inspection fee. A licensed C-16 contractor will have to submit plans for review and approval and modify the fire sprinkler system in accordance with NFPA 13, 1999 Edition. A licensed C-16 contractor shall do all sprinkler work and certification. The approved plans, with Fire Department Job card must be at the job site for all inspections. 6) As may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire sprinkler system plans for the tenant improvement area may be required to be submitted to the Fire Department for review, along with a plan/inspection fee. The sprinkler system will have to be modified and designed in accordance with NFPA 13, 1999 Edition. A licensed C-16 EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 200 FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 contractor shall do all sprinkler work and certification. The approved pproved plans, with Fire Department Job card must be at the job site for all inspections. 7) Whenever sprinkler overhead mains of 4" size or larger are provided, the Riverside County Fire Department requires documentation from a structural engineer that the roof structural members will be capable of supporting the weight of the water filled mains and attached lines. Provide appropriate detailed documentation, with a wet stamp and signature, by the project structural engineer.' Buildings/facilities 8) Provide either a separate Knox Key Lock box, Model 4400, 3200 or 1300, mounted per recommended standard of the Knox Company or provide key(s) for inclusion in the general building Knox Box. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. Special forms are available from this office for the ordering of the Knox Box. This form must be authorized and signed by this office for the correctly coded system to be purchased. 9) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. 10) If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. 11) If the facility requires Hazardous Materials Reporting (Material Safety Data sheets) the Knox Haz Mat Data and Key Storage Cabinet, Model 1220 or 1300 with tamper switches shall be used. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock box will require "tamper" monitoring. Other requirements: 12) Directory display boards will be required adjacent to each roadway access to the development. These shall be an illuminated diagrammatic representation of the actual layout that shows the name of complex, all streets, building designators, unit numbers and fire hydrant locations within the complex. These directories shall be a minimum of 4' x 4' in dimension. Addressing of buildings and units shall conform to the Riverside County Addressing Policy. Additional information and details may be obtained by contacting the Fire Department Planning staff. 13) Install panic hardware and exit signs as per Chapter 10 of the 2001 CBC. 14) All egress doors shall comply with CBC Sec. 1003.3.1.8 for proper door hardware and as noted on Sht. of the building plans. 15) Prior to final inspection of any building, the applicant shall prepare and submit to the Fire Department for approval, a site plan designating required fire lanes with appropriate lane painting and/or signs. 16) Certain designated areas will be required to be maintained as fire lanes. 17) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact a certified extinguisher company for proper placement and spacing of equipment. 18) If the building is used for high piled/rack storage, the building construction and fire sprinkler system must meet 1999 NFPA 13 and Article 81 of the 2001 CFC. EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2n° FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 19) Shelving, counters, etc., must be in place, however, no merchandise may be placed in the building prior to inspection. 20) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12" for building(s) up to 25' in height, and 24" in height for building(s) exceeding 25' in height. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must be legible and of a contrasting color with the background and adequately illuminated to be visible from the street at all hours. 21) Electrical room door shall be posted "ELECTRICAL ROOM" on the outside of door. 22) Room capacity shall be posted in a conspicuous place on an approved sign near the main exit from the room. 23) A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit doors. The sign shall be in letters not less than one inch high on a contrasting background. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely; Tracy Hobday Chief Fire Department Planner By, y; Sonia Cooley James Aldrich Fire Safety Specialist Fire Systems Inspector EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2n° FI., Indio, CA 92201 . (760) 863-8886 • Fax (760) 863-7072 cn rn 7r� m Fri C:7 0 % I I 22 D 14 < > o I' I • I . I I -:47--7 Ouc J g le'%C7rU 0 CNIA-nnkl A?-V� U By 0 PA, R TIM. E N, '�U V -D 'y co", -"'Lop By EXHIBIT V CASP AIO. �o -7 15 bo , Nev) V" ul P� C(Ye 0 APPROVr'D BY COrMNAU"NUTY DEVELOPMEINT DEPARTMIEiv, BY vv :D DATE EXHIBIT KbUill' CASE NO, SD F a () () — 6 f-1 I/ — .P-,�t4v ovi- lAJi/)W/) I& n V-'eqn 63MMUNITY DEVELOPMIEINT CEPAPT um- TITLE 24 REPORT Title 24 Report. for: Komar Desert Center - Bldg A Highway 111 and Jefferson . La Quinta, CA 92253 Project Designer: SGPA Architecture Planning. 1545 Hotel Circle South, Studio 200 San Diego, CA CITYolLAQUINTBVILDI� F A ETY DEPT. FOR P�O�E® ONSTRUC71ON Report Prepared By: Chris;French LSW Engineers California, Inc. 5560 Ruffin Rd., #1 San Diego, CA 92123 (858) 268-3224 D AUG 31 2001 Job Number: 2006796 BY Date: 07,8` 8/29/20077 . The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and.Non residential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number. 2006796 User Number: 3137 •q. C ',_M . PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME DATE Komar Desert Center - Bldg A 8/29/2007 PROJECT ADDRESS SIGI Highway 111 and Jefferson La Quinta 19,233 Sq.Ft. PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # SGPA Architecture Planning HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION DOCUMENTATION AUTHOR TELEPHONE Checked by/Dafe LSW Engineers California, Inc. 858 268-3224 Enforcement Agency use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DATE OF PLANS SIGI BUILDING CONDITIONED FLOOR AREA 19,233 Sq.Ft. 7CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL a HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION E:] EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGI DATE Chris French 1 9-2-9-&7 The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. 0 F� F-] 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. FI F-1 R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. n FI F-1 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Fo E PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATU LIC. NO. DA '1J007 SGPA Architecture Planning2 �p� LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandato Measures I Lighting Compliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MEC -1 MECH-2 MECH-3 MECH-5 Required F PRINCIPAL MECHANICAL DESIGNER - NAME SIGN E LIC. NO. DATE Devin A. Abellon P.E./LSW Engineers C Al r I EnergyPro 4.3 by EnergySoft User Number: 3137 Job Number: 2006796 Page:2 of 9 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME DATE Komar Desert Center - Bldq A I 8/29/2007 ENERGY COMPONENT Standard Design Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type Proposed Design sgft. sgft. sgft. Compliance Margin Sundad - "`� Pied" - `"----- Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: Percent better than Standard: 0.37 0.11 0.26 f, '; "'"""" °M" •. `": ' k "0 0 2040 80 80'100120140160180200220240260280900 process) 317.18 286.84 30.34 56.47 69.20 -12.73 0.00 0.00 0.00 0.00 0.00 0.00 13.92 13.92 0.00 166.26 165.26 0.00 82.16 82.1 a 0.00 o.00 o.00 0.00 635.38 617.51 17.86 2.8% 2.8% excluding Building Orientation Number of Stories Number of Systems Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 19,233 sgft. sgft. sgft. 1 o 6 19,233 1 Natural Gas 2,795 sgft. o sqft. Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N 1,961 sgft. 0 sgft. 0.0% Left Elevation E 2,795 sgft. o sqft. 0.0% Rear Elevation s 2,534 sgft. 253 sgft. 10.0% Right Elevation Ww Total Roof 2,426 sgft. 946 9,716 sgft. 1,199 19,233 sgft.sgft. sgft. sgft. 39.0% 0.0% Standard Proposed Lighting Power Density 1.500 w/sgft. 1.500 W/sgft. Prescriptive Env. Heat Loss 5,010 Btu/h a,22s Blum Prescriptive Env. Heat Gain 342,131 Stum-F 422,534 Btulh-F Remarks: EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796 Page:3 of 9 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Komar Desert Center - Bldg A DATE 8/29/2007 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Ctrl. Allowed LPD Proc. Credits Area Tailored Loads • (W/sf)2 (W/s3 W/s 4 (W/sf) RTU 1 - RTU -6 Main Comp Bldg Retail and Wholesale 19,233 '1.50 Notes:1. See LTG 2-C 2. See LTG -4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof Komar R-30 Roof is a CRRC Certified Roof with Reflectance = 0.30, Emittance = 0.75. The HVAC System "Carrier 50HJQ0014-5 w/ DCV" includes Demand Control Ventilation per Standards Section 121. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. I EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796 Page:4 of 9 1 CERTIFICATE OF COMPLIANCE ENV - PROJECT NAME DATE Komar Desert Center- Bldg A � ,, - • 8/29/2007 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Wall 123 0.184 None R-10.0 270 90 New 12-A10 Main. 2 Wall. 2,28' 0.184 None R-10.0 180 90 New 12-A10 Main 3 Wall 2.73 0.184 None R-10.0 90 90 New 12-A10 Main 4 Door 2 0.700 None R-0.0 90 90 New 28-A2 Main 5 Door 2 0.700 None R-0.0 90 90 New 28-A2 Main 6 Door 2 0.700 None R-0.0 90 90 New 28-A2 Main 7 Wall 1,96 0.184 None R-10.0 0 90 New 12-A10 Main 8 Wall 25 0.1841 None R-10.01 315 90 New 12-A10 Main 9 Roof 19,23 0.063 R-30 R-0.0 0 0 New 05-A22 Main 11 Window Right NW 320 1.220 NI -1 0.80 116-B 315 New Nonres Single Metal Clear IMain IF More than or equal to 10,000 sq.ft. of site -built fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default label Certificate using the default U -factors from I Standards Table 116-A and B. Certificate shall be filed In the contractors orolect office dudna construction and In the building managers office after construction # T e Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments -1_Window Right W 11 1.220 NI -1 0.80 116-B 270 New Nonres Single Metal Clear Main 2 Window Right W 22 1.220 NI -1 0.80 116-B 270 New Nonres Sin le Metal Clear Main 3 Window Right W 22 1.220 NI -1 0.80 116-B 270 New Nonres Single Metal Clear Main 4 Window Ri ht W 63 1.220 NI -1 0.80 116-B 270 New Nonres Single Metal Clear Main 5 Window Right W 127 1.220 NI -1 0.80 116-B 2701 New Nonres Sin le Metal Clear Main 6 Window Right W 127 1.220 NI -1 0.80,116-B 270 New Nonres Single Metal Clear Main 7 Window Right W 127 1.220 NI -1 0.80 116-B 270 New Nonres Single Metal Clear Main 8 Window Ri ht W 127 1.220 NI -1 0.80 116-B 270 New Nonres Single Metal Clear Main 9 W in ow, Rear S 127 1.220 NI -1 0.80 116-B 180 New Nonres Single Metal Clear Main 10 Window Rear S 127 1.220 NI -1 0.80 116-B 180 New Nonres Single Metal Clear Main 11 Window Right NW 320 1.220 NI -1 0.80 116-B 315 New Nonres Single Metal Clear IMain (1) 1.1 -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 10.0 6.3 8.0 0.1 26.0 15.8 5 None 0.76 10.0 12.7 8.0 0.1 15.8 1.8 6 one 0.76 10.0 12.7 8.0 0.1 1.8 15.8 7 None 0.76 10.0 12.7 8.0 0.1 12.0 23.0 8 None 0.76 1 10.0 12.7 8.0 0.1 33.0 1.8 9 None 0.76 10.0 12.7 1.3 0.1 2.0 16.0 10 None 0.76 10.0 12.7 1.3 0.1 16.0 2.0 11 None 0.76 10.0 32.0 1 10.0 3.0 7.0 7.0 0.1 4.0 0 0.1 4.0 0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES LThe proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 112, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/112. Sea Section W(c). If this box is checked, ENV4-C must be filled out. when submitting under the Proscriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 3137 Job Number: 2006796 Page:5 of 9 1 CERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME DATE Komar Desert Center - Bldg A 8/29/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratino and maintenance information meet the requirements of Section 10-103fb1 and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are Installed at the factory and certified with the commission do not require equipment testing but do require construction Inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required It the unit serves 5,000 R2 o1 space or less and 25% or more of the ducts are in noncondffioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV Ian volume controls Installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chiflers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -VariableFregriencyContMIS Applies to all now distribution pumps on new variable flow chilled, hydronlcheat pump or condenser we ter systems where the pumps motors are greater than 5 hp. Equipment requirin acceptance testing EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796 Page:6 of 9 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE Komar Desert Center - Bldg A- 8/29/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS Central or Single Zone RTU 1 - RTU -6 6 Reference on Plans or Specification 1 112(a) 3.20 COP 112 a 9.8 EER 112 b Yes 112(c), 115(a) n/a 121(b) Yes 121 b 4808 cfm 121 c No 121 c Yes 121 c 122 a Pro rnmmable Switch 122 a Heatin & Cooling Required 122 f Auto 122 Na 123 124 1 R-8.0 144 a & b n/a 144 a & b 771,074 btuh 144 a & b n/a 144 a & b 654,772 btuh 144 c Constant Volume 144 c 144 c Yes 144 d -No 144 a Diff. Tem (Integrated) 144 f Constant Tem 144 (f) Constant Temp 144 k No 1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put 'N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System Is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.3 by EnergySott User Number. 3137 Job Number: 2006796 Page:7 of 9 1 MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE Komar Desert Center - Bldg A 1 8/29/2007 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E I F G H I I J K L M N ZONE/SYSTEM n a'm v1 •a Biu N a dTo �t ��� o° tr 3 x D C)mT v 01 3 Z 3 cQ M. 0 myn T GSM 3 tS � m xa TCT ..; 9 _ °yD o �o ° M n 0'a° T»v_, E m _ N Ca o n02 TN"" �c° v Fo n x �o x t7 O D mad o oyx T M ° a m3 .0 09 D y m a W Main 19,232 0.22 4,231 4,231 4,808 RTU 1 - RTU -6 Total 4,231 4,808 t t 1 c Minimum ventilation rete per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occuant load foregress purposes fors aces without fixed seatin . H Required Ventilation Air REO'D V.0. is the lar er of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply cfm Fan CFM x 30%; or K Condition area ft. s x 04 cfmFd. sq.,. or L Maximum of Columns H, J, K, or 300 clm ' M IThis must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column I) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column I) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796 Page:8 of 9 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Komar Desert Center - BldgA TANK INSUL. DATE 8/29/2007 CHILLER AND TOWER SUMMARY Distribution Type Oty Efficiency Tons PUMPS Ext. R -Val. Equipment Name Equipment Type Oty. Tot. City GPM I BHP Motor Eff. Drive Eff. Pump Control MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Pipinq Len th(ft) Control # HP Type In Plenum Outside Buried Add 1/2" Insulation DH BOILER SUMMARY Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Oty Rated Input Vol. (Gals.) Condition Status Ext. R -Val. MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Pipinq Len th(ft) Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type PW Output Aux. kW Eff. Output Efficiency Condition Status Economizer Type Carrier 50HJ00014-5 w/ Packaged DX 6 138,000 12.4 3.20 COP 146,000 9.8 EER New Diff. Temp (Integrated) CENTRAL SYSTEM FAN SUMMARY SUPPLIIFAN RETURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 50HJ00014-5 w/ DCV Constant Volume Draw -Through 5,000 1.84 84.0% 97.0% none Run Initiation Time: 00/29/07 16:21:40 Run Code: 1188429 00 EnergyPro 43 by EnergySoft User Number. 3137 Job Number: 2006796 Page:9 of 9 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.42 X 66,039 S.F. or $27,736.38 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Bank of America - Clint Knox Name on the check By Dr. Doris Wilson Superintendent Check No. 417710296 Telephone Funding Commercial LJ v Z. Fee collected /exempted by Shar, n MC $27,736.38 II rey Payment Recd $0.00 � �.e % -,Over/U�der' Signature C r NOTICE: Pursuant to Government Code Section 66020(d)(1), this will se e t notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the wilding or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original- Building Department/Applicant Copy -Applicant/Receipt Copy - Accounting A dit6ion of hnperiallrrigation District 8 1 -600 Avenue 58 • La Quinta, CA 92253 • www.iid.com 11DPD-DDC_ May 15, 2007 Komar Investments, LLC ` Attn: Clint Knox 23 Corporate Plaza, Ste. 247 Newport Beach, CA 92660 Subject: Available Short Circuit Current Calculation for Komar Desert Center, for Building A, 79-815 Hwy. l 11, La Quinta, CA for a Service Voltage 120/208V, 3 Pbase,1200A Panel.- Dear anel:Dear Mr. Knox: , The available Short Circuit Current at the secondary terminals of the transformer is 61,200 Amps RMS, Symmetrical at 208 volts. This is based upon the following information: i 1) Transformer size: .1000 KVA 2) Transformer impedance: .4% 3) Primary voltage: 7,200/12,470Y volts 4) Secondary voltage: 208 volts 5) High -side KVA available: 185,000 KVA 6) Transformer connection: Wye/Wye 7) No motor contribution to fault current.. Please contact me should you have any questions, at (760) 398-5820. T�F�' You, Carlos Partida CP/ms SECT-AULT.LtrXomurBuildingA rroiec CITY OF LA QUINTA BUILDING & SAFETY DEPT: 0 ry DATE /0 gy /L I Manager jENGINEERS, INC. 8380 MIRAMAR MALL, SUITE 225 • SAN DEGO.-CAUFORMA 92121 858/453-7339 • FAX 858/453.7445 November 19, 2007 Project No. 3234.7 Mr- 14&e A9hor SCCA ATditcm re . Planning 1545 Had Code South, Studio 200 San Dkm CA 92108 Re: Komar Desmt Center, Buildings A Highway 111 dt Jefferson La Quhua, CA 92253 Dear W. Ashor. This letter is in regards to the above reftraieed project site visit on November 163 2007, for observing the I-ISS6x6xl/4 uderior csobnnm damaged due to being hit by the Forklift. Mr. Steve Kurtz and Mr. Brad Hoyt ofThe Bergman Companies were present at the site. Based on the visual obsovadon of the column, the following is our comments: I. Cut the damaged 13SS6x6xl/4 cohscmn r above do corsscaete ebb and 8" below the steel truss girder connection, and fall pain. weld a new HSS6x6x1/4 column instead. In addition it was observed that the top chord of the steel truss girder, .fiaming into the dammed column was twisted as Well. This issue shall be reviewed and resolved by the steel truss girder purer. 2. During err walk thru building A k.was moored that the exterior canopy commotion to the building wall, in detail I7/SD3, the L6x3 1/2 IS angle did not have 3" long rdoued holes as called-out on the detail. This problem shall be faced by the eo>aaactor, rind the 3" slotted holes shell be added. The bolt shallI be neutered on the slotted holes. Our comments are only intended to help the cow and speciate inspectors im pafonr ag their work, and should not be consideted as approval ofthe consbuctioa ffyou have any questions, please feel f= to contact me. Andre Malek;, S.E. Malek Engineers, Inc- MEMBER OF STRUCTURAL ENGINEERS ASSOCIATION OF CALIFORNIA John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of Banning .:. Beaumont 44. Calimesa A. - Canyon Lake Coachella Desert Hot Springs Indian Wells .• Indio I. Lake Elsinore ee La Quinta .:. Moreno Valley Palm Desert Perris Rancho Miraee Rubidoux CSD ❖ San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglionc, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 663-6666 Fax (760) 863-7072 Date 5I1 .`b La Quinta Building Department The Riverside County Fire Department is granting the fire clearance for the following location / `7 Please call if you should have questions. 760-863-8886. Thank You V fully,j,4 tubble Fire Safety Specialist John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning r Beaumont 4- Calimesa Canyon Lake 4;. Coachella 4. Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley 4. Palm Desert ..1. Perris 44. Rancho Mirage .;. Rubidoux CSD Ae San Jacinto 4- Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanan Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date g hly— La Quinta Building Department RE 4W ( �9 W-� Wlejo� LA,C�L -07_ 6P-Me 041 The Riversidelcounty Fire Department is granting the fire clearance for the following location Please call if you should have questions. 760-863-8886. Thank You Respectfully, Ja Stubble Fire afety Specialist John R- Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning Beaumont Calimesa .;. Canyon Lake 0. Coachella Dcscrt Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley .;. Palm Desert Penis Rancho Mirage Rubidoux CSD San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 La Quinta Building Department RE P rr aN C LAd-a7_ 8EDJa The Riverside County Fire Department is granting the fire clearance for the following location -7q -- V5 Please call if you should have questions. 760-863-8886. Thank You Respectfully, yJasntubble Fire Safety Specialist John R Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning Beaumont Calimesa Canyon Lake Coachella Desert Hot Springs 44. Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage Rubidoux CSD San Jacinto Temecula Board of supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RNERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date Jr 1 7 La Quinta Building Department RE �Ui'►'i D,& 8L 66 L'4-a—p1_ A-0q.3 The RiversideCountyFire De partment is granting the fire clearance for the following L location 1 1^� Ifl Please call if you should have questions. 760-863-8886. Thank You Respectfully, tv—a Jaso Stubble Fire Safety Specialist John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning 4. Beaumont Calimesa .;. Canyon Lake .;. Coachella Desert Hot Springs 404 Indian Wells Indio Lake Elsinore La Quinta Moreno Valley .;. Palm Desert .• Perris .;. Rancho Mirage .# Rubidoux CSD .;. San Jacinto . Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date S La Quinta Building Department RE 14mdrU$ Q--07 —O The Riverside County Fire Department is granting the fire clearance for the following location -7 � 7 Please call if you should have questions. 760-863-8886. Thank You Respectfully, Ja rnStubble Fire Safety Specialist John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of Banning A. - Beaumont le Calimesa .; Canyon Lake Coachella Desert Hot Springs Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert ., Perris 4. Rancho Mirage 4. Rubidoux CSD 4;. San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd. STE 201 Palm Desert. CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 Date 5 b� La Quinta Building Department RE i�QMdr De)lrr Een�r P O G F r- 0 --0'7- OF-01H The Riverside County Fire Department is granting the fire clearance for the following location 79 -- 779 gaV 1 I I Please call if you should have questions. 760-863-8886. Thank You Respectfully, Jas Stubble Fire Safety Specialist 30-DAY TEMPORARY Certificate of Occupancy EXPIRES JUNE 09,2008 Tw�p -at 4 QUAM Building &Safety Department This Temporary Certificate, issued pursuant to the requirements of Section 109 of the California Building Code, and with the concurrence of the Public Works Department and Community Development Department, certifies that the SHELL BUILDING, at the time of issuance, was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-815 HIGHWAY 111 (BUILDING "A") Use classification: COMMERICAL Occupancy Group: B & M Owner of Building: KOMAR INV Building Official Type of Construction: TYPE V -N 4 A CONSPICUOUS PLACE Building Permit No.: 07-819 Land Use Zone: CR Address: 23 CORPORATE PLZ STE 247 City, ST, ZIP: NEWPORT BEACH, CA 92660 By: STEVE TRAXEL Date: MAY 09, 2008