Loading...
14410 (AR)Building g AdL''res54-758 Inverness Owner George Ga? logly Mailing" ' Same Address Cit Ea,Quina zip 92253 Contractor 'Integrity Colftsttuct ion Address 54-705 Ave. Carranza Cita• Quinta,. v, Zip 92213 State Lic.2��& & Classif. "Arch., Engr., ' Designer Address c&-ty/ 4 - 4 Q" . P.O. BOX 1504 78-495 CALLE TAMPICO LA OUINTA, CALIFORNIA 92253 No. x.441.0 BUILDING: TYPE CONST. OCC. GRP. A.P. Number Tel. _ Legal Description Project Description Room Addition Tel City Lic. # Sq. Ft. X433 No. No. Dw. Size Stories Units New ❑ Add'❑ Alter ❑ Repair 0 Demolition ❑ Tel. City Zip I State Lic. # LICENSED CONTRACTOR'S DECLARATION r that I am licensed under provisions of Chapler 9 (commencing with Section 3 of the Business and Prof tons- -Gode, Aid my license is in full I c0 and - SIGNATURE' DATE - 1 ' • OWNEWBUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following BY: reason: (Sec. 7031.5,Susiness and Professions Code:- Any -city or county, which, requires a Minimum Setback Distances: permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also • requires the applicant for such.permit to rile a signed statement.that he is licensed pursuant to PERMIT , the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) or - Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and ,the basis for the Any Section 7031.5 by 'any for - Plan Chk. Dep. alleged exemption. violation of applicant apermit " subjects the applicant to a civil penalty of -not more than five hundred dollars ($500). . Plan,Chk. Bal. O I, as owner of the property, or my. employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. Code: The Contractors- License Law does not apply to an owner of property who DAMAGES AS PROVIDED FOR IN SECTION 3706.OF THE LABOR CODE, INTEREST, AND builds or Improves thereon and who does such work himself or through his -own -employees, Mech. .. provided that such Improvements are not Intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner -builder will have.the burden Electrical of proving that. he did not build or improve for the purpose of sale.) O 1, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing ' struct the project. (Sec. 7044, Business and.Professlons Code: The Contractor's License. Law - does not apply to an owner of property who builds or improves thereon, and who contracts for . S.M.1.- such projects with a contrsctor(s) jicensed pursuant to the Contractor's License Law.) - Grading - ❑ 1 a exempt under Sec. B. & P.C. for this reason mentioned property for inspection purposes. Driveway Enc. Infrastructure Date Owner WORKERS' COMPENSATION DECLARATION •' I hereby affirm that l have a certificate of consent to self -insure, or a certificate of Worker's Co_Mpensation Insurance, or a certified copy thereof. (Sec. .3800, Labor Code.) Policy / -Company Copy is filed with the city. ❑ Certified copy is hereby furnished. . CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION -INSURANCE (This section need not be completed If the permit is for one hundred dollars ($100) valuation or less:). . . I certify that in the performance of the work for whichthispermit is issued, I shall not employ any person in any'manner so as to become subject to the Workers' Compensation Laws of California •0U AMOUNT 99. 45 513.00 35.�Ci 20.88 1.31 TOTAL 2�a REMARKS VIA til � _• Date Owner NOTICE TO APPLICANT: H, after making this Certificate 'or Exemption you should become.. ' ZONE: BY: subject to the Workers' Compensation provisions m. me Labor Code, you must forthwith, comply with such provisions or this permit shall be'deemed revoked. Minimum Setback Distances: Front Setback from Rear Setback from WARNING: FAILURE To SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND Side Street Setbacl SHALL"SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO.THE COST OF COMPENSATION_ Side Setback fro DAMAGES AS PROVIDED FOR IN SECTION 3706.OF THE LABOR CODE, INTEREST, AND ATTORNEYS FEES. This is a building permit when properly filled out,'signed and validated, and is.subject to FINAL DATE expiration if work thereunder is suspended for 180 days. ., 1 certify that I have read this application and state that the above information is correct. Issued by: Date_ I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this. city to enter the above-. -. mentioned property for inspection purposes. Validated by: T Signature of applicant Date Mailing Address Validation: City, State, Zip k% CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBINU FEES 1ST FL. SO. FT. ® $ 2ND FL. SO. FT. p POR. SO. FT. ® GAR. SO. FT. CARP. SQ. FT. WALL SO. FT. ® SO FT ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES HEATING (ROUGH) WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER DUCT WORK GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED G( 1 LAUNDRY TRAY AIR HANDLING UNIT CFM HEATING (FINAL) KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB BOND BEAM SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11A c SEWAGE DISPOSAL LUMBER GR. SO.FT.GAR ® 3/ac HOUSE SEWER FINAL INSP. ', ROOFING GAS PIPING PERMIT FEE REMARKS: PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE' CONST. FEE ELECT. FEE . . SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK' ROUGH WIRING DUCT WORK 'ROCKSTORAGE FOUND. REINF. .' G(• G( 1 GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APP./EQUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING' -'—CU. yd. .$—Plus -4—_$— LUMBER GR. �AL INSP. RAMING Z•LQ FINAL INSP. ', ROOFING //'j�/ \/ REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL THING MESH . U INSULATION/SOUND42 FINISH GRADING INAL INSPECTIONOF—f CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES11NITIALS GARDEN WALL FINAL ARCHITECTURAL/LANDSCAPE VARIANCE APPLICATION PGA WEST RESIDENTIAL ASSOCIATION, INC. Please complete and include this request form, along with four (4)sets of your proposed home improvement plans to: PGA WEST RESIDENTIAL ASSOCIATION, INC. P.O. Box 1060 La Quinta, CA 92253 or, 55-940 PGA Boulevard La Quinta, CA 92253 �. Attn: Property Manager ' NAME: ��� Zto6 d�.,d G'�s91/' �i1 Lc of Ly DATE: ADDRESS: SSR T'�� �,r` �'•nlc$`SJ 1-11l (Zsa l9 2 -)- PHONE: ) -PHONE: UNIT: PROPOSED STARTING DATE: ti�?v'b�►'l, lSSi APPROXIMATE COMPLETION DATE: JTZ• b. 1 Homeowner's Signature The following appropriate information should accompany your -completed application: 1. Four (4) sets of complete plans -to include: a. Improvements and/demolitions b. Plot plan. c. All dimensions proposed d. Relationship to neighboring units e. Material and color scheme f. Planned modifications of all external systems (landscape, x' sprinklers, gas lines, electrical, etc.) 2. Agreement and Covenant Running with the Land completed and notarized. Two (2) original. 3. Conditions of Approval and Disclaimer form (signed) r 4. Facing and Adjacent Neighbor form (if applicable) 5. Construction°Regulations form (signed) ELECTRICAL [ ] Approved [ ] Disapproved Signature Date LANDSCAPE [ ] Approved [ ] Disapproved Signature Date ARCHITECTURAL COMMITTEE [� Approved [ ] Disapproved Signature Date ARCH/Rev 6/94 1 2��� syCu�iiz� -vva�a ✓jw. , rpc�coa~ cpn��irzer�ra �ocia,C,ian a� 9983 It is my professional opinion that the additional thirty some square of roof added will have very little lateral effect on the existing structure and that the existing design is capable of distributing the additional shear to the original shear walls. I have attached an analysis for the design of the gravity load members. If you have any additional concerns, please feel free to contact my office at your convenience. Sincerely, Dennis S. Wish PE Structural Engineering Consultant dw/DS W Enclosure: Gravity load analysis cc: Mr. Terry Smith � November 29, 1994 Mr. Mark Harold Dennis S. Wish PE City of La Quinta StructuralEigineerirg Department of Building and Safety Consultant 78-495 Calle Tampico La Quinta, California 92253 54-625 Avenida Bermudas Dear Mark: La Quinta, CaliforniaC 92, I have been retained by Mr. Terry Smith of Integrity Construction to design the necessary structural elements for the small room addition to the residence in (619),564-0884 PGA West - 54-785 Inverness. I visited the city this morning and reviewed the -the "Legends . original structural plans for Mediterranean" . (M) style 20, 30, and 30A as designed by Nick Gouvis. The existing structure extends at the eaves approximately two to three feet past the face of the bearing walls. Inasmuch as the total extension to this plan will not exceed eight feet, the lateral loads induced by this extension would transfer very little additional shear to the existing noted shear walls. Although the addition is listed as 168 square feet, there is currently 123 square feet of existing roof over the patio area that is to be enclosed by this addition. The addition of the new exterior walls will replace the existing exterior walls and therefore do not add sufficient lateral load as well. The weakest direction would be parallel to the home. The south most wall (relative to the Gallogly plan) is solid and without openings. The weak corners are to be dragged into the existing framing in order to assure that the structure is tied together. I have instructed Mr. Smith to indicate appropriate straps and details on the plans. 2��� syCu�iiz� -vva�a ✓jw. , rpc�coa~ cpn��irzer�ra �ocia,C,ian a� 9983 It is my professional opinion that the additional thirty some square of roof added will have very little lateral effect on the existing structure and that the existing design is capable of distributing the additional shear to the original shear walls. I have attached an analysis for the design of the gravity load members. If you have any additional concerns, please feel free to contact my office at your convenience. Sincerely, Dennis S. Wish PE Structural Engineering Consultant dw/DS W Enclosure: Gravity load analysis cc: Mr. Terry Smith