Loading...
10-0599 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA, QUINTA, CALIFORNIA 92253 Application Number: 10-00000599 Property Address: 55505 PEBBLE BEACH APN: 775 -130 -007 -- Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY -RESIDENTIAL - Application valuation: 35000 Tiht 4 4 " . - ,. BUILDING & SAFETY DEPARTMENT ' BUILDING PERMIT Owner: DELAMARTER BRIAN R & JANNA L 3396 STONE RIDGE LN LOS ANGELES; CA 90077inD � f - VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/12/10 Contractor: OCT.12 1 21110 Applicant: Architect or Engineer: 7C' S CONSTRUCTION & U 4,::*j4L€S 48236 VISTA DE NOPAL' 4 %7CT LA QUINTA, CA 92253 CITYOFI.AQUINTA /RC1' (760) 564-5811 F1°I010E0EFT Lic. No.: 594043 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury th licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busin s an Professionals Code, and my License is in full force and effect. License Class: B LicenseNo.: 594043 %,.ea'te,1U -a ✓Contractor: R -BUILDER DECLARATION I hereby affirm under penalty of peJVe2empt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7631.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) "j, as owner of the property, or my employees with wages as their sole compensation, will do the work, and " the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion; the owner -builder will have the burden of proving that he or she did not build of improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License. Law does not apply to an owner of • property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). - (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following. declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers', compensation insurance carrier and policy number are: Carrier STATE FUNDAORKE44OMPENSATION olicy Number 0026211-2008 I certify that, in thee of t e work for which this permit is issued, I shall not employ any person in any mo be me subject to the workers' compensation. laws of California, _ and agree that, icom subject.to the workers' compensation provisions of Section 3700 of the LabCole,e orth h comply with those provisions. i Date: / �(�l�ppficant: WARNING: FAILURE TO SECURCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject'to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a. result of this application becomes null and void if work is not commenced - ,within 180 days from date of issua*above or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and statformation is correct. I agree to comply with all city and county ordinances and state laws-relatinrut ' and hereby authorize representatives of this%/cc�'ounty to enter upon the above-mentioneec purposes.Date/V�ySignature (Applicant or Age Application Number 10-00000599 ------ Structure Information 5600 SF EXISTING SFD ----- Construction Type TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION '2007/08 ----------------------------------------------------------------------------- ENERGY. Permit BUILDING PERMIT Additional desc . Periri,t PPP 317.00 Plan Check Fee 206.05 Issue Date Valuation 35000 Expiration Date 4/10/11 Qty Unit.Charge Per Extension BASE FEE 252.0.0 10.00 6.5000 THOU BLDG 25,001-50,000 65.00 -------------- Special Notes and Comments --- WINDOW & STRUCTURAL FRAMING REVISIONS TO REAR OF RESIDENCE. 2007 CODES. 2008 ENERGY. U -FACTOR =..59 SHGC = .45 Other Fees ... . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) - RES 3.50 Fee summary Charged Paid, Credited, Due Permit Fee Total 317.00 .00 .00 317.00 Plan Check Total 206.05 :.00 .00 206.05 Other Fee Total 26.11 .00 .00 26.11 Grand Total 549.16 .00 .00 549.16 - LQPERD4IT BUILDING ENERGY ANALYSIS REPORT PROJECT: Delamarter Residence_ ._ L 55-505 Pebble Beach—_-_ , La Quinta, CA Project Designer: � CA�PIC:16=�• CITY OF LA QUINTA BUILDING & SAFETY DEPT. : APPROVED ,FOR CONSTRUCTION i i DATEbfl tl BY Report Prepared by:' ��_. ,-.- _ .:..- " Joan D. Hacker Insu-form, Inc. 77-810 Las Montana Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 Job Number: IIECEIVI=) - Date: SEP 0 2 2010 8/27/2010 BY: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-27T13:14:4 /D: PERFORMANCE CERTIFICATE: Exterior Sidefins Residential Project Name Part -1 of 5 Building CF -1 R Delamarter Residence Type m Single Family ❑ Addition Alone 0.73 Project Address ❑ Multi Family ® Existing+ Addition/Alteration Date 55-505 Pebble Beach La Quinta California Energy Climate Zone Total Cond. Floor Area 8/# Addition one 15 5,600 o FIELD INSPECTION ENERGY of/St�r�� � ❑ Yes ❑ No HERS Measures CHECKLIST 1.190 El Yes ElNo Special Features -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. INSULATION -- If Yes, see Part 2 of 5 of this form for detail;. 2.0 Construction Type Area Special 10.0 Wall Wood Framed Cavity (ft) Features see Part 2? of 5 StatUS Roof Wood Framed Attic R-11 1,870 2.0 Slab Unheated Slab -on -Grade R-19 5,600 Existing Wall Wood Framed None 5,600 Perim = 203' Existing R-13 204 Existing New (NE)t(NE) 21.0 Rear (SIM 72 0 Rear (Sl9 96 0 HVAC SYSTEMS Qty. Heatin 3 Central Furnace U - Exterior Sidefins Factor SHGC Overh 0.710 0.73 2.0 0.710 0.73 2.0 0.710 0.73 2.0 0.710 0.73 2.0 1.190 0.83 2.0 0.710 0.73 2.0 0.590 0.45 10.0 0.710 0.73 2.0 0.590 0.45 2.0 0.710 0.73 2.0. 0.710 0.73 2.0 HVAC DISTRIBUTION Location Heatin .iving Zone Ducted WATER HE NTA I G Qtv. Tvnp 5.0 Min. Eff Cool ling Min. Eff 75% AFUE Split Air Conditioner 12.0 SEER Cooling Duct Location Ducted Attic, Ceiling fns, vented Gallons Min. Eff Distribution Run Code: 20 f 0.08-27T13 Status Existing Existing g Existing Existing New Existing New Existing Existing Thermostat Exterior Sidefins Shades none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen none Bug Screen Min. Eff Cool ling Min. Eff 75% AFUE Split Air Conditioner 12.0 SEER Cooling Duct Location Ducted Attic, Ceiling fns, vented Gallons Min. Eff Distribution Run Code: 20 f 0.08-27T13 Status Existing Existing g Existing Existing New Existing New Existing Existing Thermostat Status Setback Existing Duct R -Value Status 4.2 Existing Status Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 iof 5 CF -1 R Project Name Delamarter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition..Alteration Date 6/27/2010 Project Address 55-505 Pebble. Beach La Quinta .. California Energy Climate Zone CA Climate Zone 15 . Total Cond. Floor Area 5,600 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Rear (SW 60.0 0.590 0.45 2.0 none Bug Screen New Rear (SlM 24.0 0.710 0.73 2.0 none Bug Screen Existing Rear (SlM 16.0 0.710 0.73 2.0 none Bug Screen Existing Right (NlM 66.7 0.710 0.73 2.0 none Bug Screen Existing Right (NM 32.0 0.710 0.73 2.0 none Bug Screen Existing Right (NlM 33.4 0.710 0.73 2.0 none Bug Screen Existing Right (NlM 16.0 0.710 0.73 2.0 none Bug Screen Existing Rear (WJ 30.9 0.590 0.45 2.0 none Bug Screen New Left (S) 65.0 0.590 0.45 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duict Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number., 2655 Run Code: 2010-08-27T13:14:4 /D: Page 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Delamarter Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family m Existing+ Additior/Alteration Date $/27/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Fumace Exist has an AFUE less than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a com leted CF -4R form for each of the measures listed below for final to be given. EnerqyPro 5.0 by EnerqvSoft User Number: 2655 Run Code: 2010-08-27T13:14:4 /D: Page 5 of 13 R PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family O Addition Alone Date Delamarter Residence ❑ Multi Family m Existing+ AdditiDn/Alteration 8/27/2010 ANNUAL ENERGY USE SUMMARY Standard. Proposed Margin TDV kBtu/ft2- r Space Heating 4.75 4.77 -0.02 Space Cooling 149.51 141.13 8.37 Fans 31.75 30.00 1.75 Domestic Hot Water 7.30 1.30 0.00 Pumps 0.00 0.00 0.00 Totals 193.31 183.20 10.10 Percent Better Than Standard: 5.2 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 530 172 Fuel Available at Site: Natural Gas (SE) 780 237 Raised Floor Area: 0 (S K9 1,000 299 Slab on Grade Area: 5,600 (NM '620 146 Average Ceiling Height: 9.0 Roof 5.'600 0 Fenestration Average U -Factor: 0.69 TOTAL: 856 Average SHGC: 0.65 Fenestration/CFA Ratio: 15.3 REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Inti -form, Inc. 77-810 Las Montana Road, Suite 201 Joan D. Hacker 8272010 Address Name Cit State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Si ed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Q.gk ekrryp Namyr4 / City/State2ipC^ Oat '� -i 2Z4� Phone �� �,5 Y& Signed License # Date k EnemvPro5.0by EnergySoft User Number. 2655 RunCnde•2n1n-nR-27r1z e•e If) - R CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Delamarter Residence Building Type m Single Family O Addition Alone 0 Multi Family 10 Existing+ Addition/Alteration Date 1812712010 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation . Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 358 0.110 R-11 45 90 Existing 4.3.1-A2 Existing Living Wall 508 0.110 R-11 135 90 Existing 4.3.1-A2 Existing Living Wall 532 0.110 R-11 225 90 Existing 4.3.1-A2 Existing Living Wall 472 ' 0.110.R-11 315 90 Existing 4.3.1-A2 Existing Living Roof 5,600 0.049 R-19" 45 0 Existing 4.2.1-A4 Existing Living Slab 4,100 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Slab 1,500 0.730 None 0 180 Existing 4.4.7-A1 Existing Living - Wall 169 0.102 R-13 270 90 New 4.3.1-A3 Existing Living= Wall 35 0.102 R-13 180 90 New 4.3.1-A3 Existing Living FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 6.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear Existing Living 2 Window 33.4 0.710 Default 0.73 Default 45 Existing Double Metal Clear Existing Living 3- Window 10.5 0.710 Default 0.73 Default 45 Existing Double Metal Clear Existing Living 4 Window 48.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear Existing Living 5 Window 21.0 1.190 Default 0.83 Default 45 Existing Single Metal Clear Existing Living 6 Window 53.4 0.710 Default 0.73 Default 45 Existing Double Metal Clear Existing Living 7 Window 48.0 0.710 Default 0.73 Default 135 Removed Double Metal Clear Existing Living 8 Window 64.0 0.590 NFRC 0.45 NFRC 135 New IWC 6200 Alum/Low-E Existing Living 9 Wndow 72.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear Existing Living 10 Window 36.0 - 0.590 NFRC 0.45 NFRC 135 New IWC 6200 Alum/Low-E Existing Living 11 Window 72.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear Existing Living 12 Window 96.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear Existing Living 13 Window 18.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear Existing Living 14 Window 60.0 0.590 NFRC 0.45 NFRC 225 New IWC 6200 Alum/Low-E Existing Living 15 Window 24.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear Existing Living . 16 Window 16.0 0.710 -Default ` 0.73 Default 225 Existing Double Metal Clear Existing Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t: Dist Len H t 1 Bug Screen 0.76. 6.0 1.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 6.8 5.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 3.0 3.5 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 3.5 6.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.8 8.0 2.0 0.1 .2.0 2.0 7 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 8 . Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 9 Bug Screen 0.76 8.0 9.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 6.0 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 9.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 8.0 12.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 6.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.0 6.0 2.0 0.1 2.0 2.01 1' 15 Bug Screen 0.76 4.0 6.0 2.0 0.1 2.0 2.01 1 16 . Bug Screen 0.76 4.0 4.0 2.0 0.1 2.0 2.01 1 r EnergyPro 5.0 by EnergySoft User Number: 2655 Run Code: 2010-08-27T13:14:4 ID: Pae 7 of 13 I CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Delamarter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 812712010 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity_Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 66.7 0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living 18 Window 32.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living 19 Window 33.4 0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living 20 Window 16.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear Existing Living 21 Window 64.0 0.710 Default 0.73 Default 315 Removed Double Metal Clear Existing Living 22 Window 30.9 0.590 NFRC 0.45 NFRC 270 New IWC 6200 Alum/Low-E Existing Living 23 Window 65.0 0.590 NFRC 0.45 NFRC 180 New IWC 6200 Alum/Low-E Existing Living (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 6.8 10.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 4.0 8.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 6.8 5.0 2.0 0.1 2.0 2.0 20 lBug Screen 0.76 4.0 4.01 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 6.0 7.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 6.5 4.5 2.0 0.1 2.0 2.0 EnergyPro 5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-27T13:14:4 ID: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Delamafter Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1812712010 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existinq Altered Removed Volume Year Built Living Zone Existing Living 5,600 50,400 1985 Totals 0 5,6001 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 3 Central Furnace 75% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Coolinq Duct Ducts Duct Location R -Value Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n./a n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E w Hot Water Piping Length ff c Q — System Name Pipe Length Pipe Diameter Insul. Thick. Qty.HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnerPro 5.0 b Ene Soft User Number: 2655 RunCode: 2010-08-27T13:14:4 /D: Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential (Page- 1 of 3 MF -1R Project Name Delamarter Residence Date 8/27/2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory mEasures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicablE sections of the MF -1 R Form with plans. Building Envelo a Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air *,eaka e. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling ore uivalent U -factor. ' 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.30/,; water vapor permeance rate is no Qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. 'Fireplaces, Decorative Gas Appliances and Gas Log Measures: 1 50 e 1 A: Mason ry or factor -built fire laces have a closable metal or g lass door covering the entire open i.1of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. I §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupa-icies meet the air release valve, backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)S. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112Gc . §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or ,ether indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicaded on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(i)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vaporretardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Ccr oration. EnergyPro5.0 by EnergySoft User Number: 2655 Run Code: 2010-08-27T13:14:47 ID: Page 10 of 13 P_ MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Delamarter Residence 8/27/2010 §150(m)1: All air -distribution system ducts and plenums installed; are sealed and insulated to meet the requi-ements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closu-e system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of 'JL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tae shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with mat3rials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Mole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with tha Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lover than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a Ise -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.0 by EnergySoft User Number 2655 Run Code: 2010-08-27713:14:47 /D: Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Delamarter Residence 8/27/2010 §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the followingcontrols: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking,lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134 and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro5.0 by EnergySoft User Number: 2655 RunCode: 2010-08-27713:14:47 ID: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Delamarter Residence Date 8/27/2010 System Name Living Zone Floor Area 5,600 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 3,949 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 56,000 79,414 4,757 2,017 69,855 Total Output Btuh 168,000 0 Output Btuh/s ft 30.0 8,853 6,080 Cooling System 0 0 Output per System 48,0001 0 0 0 0 Total Output (Bt h) 144,000 0 4,757 0 Total Output Tons 12.0 1 8,853 6,080 Total Output Btuh/s ft 25.7 Total Output s ft/Ton 466.7 1 97,119 82,016 Air System CFM per System 1,500 HVAC EQUIPMENT SELECTION Airflow cfm 4,500 Exist 108,203 18,443 168,000 Airflow cfm/s ft 0.80 Airflow cfm/Ton 375.0 Outside Air % 0.0% Total Adjusted System Output 108,203 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 18,443 Aug 3p -ml 168,000 Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air At - 0 cfm Supply Fan 4,500 cfm 69 IF 69 OF 104 IF Heating Coil D- 103 OF ROOM ;t 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 178 °F 80164 OF 80 / 64 OF 57 / 56 OF Outside Air h 0 cfm Supply Fan Cooling Coil 59 / 57 OF 4,500 cfm 46.0% RO'fa'M 80164 OF 78 / 64 OF 4 A 4 EnergyPro5.O by EnergySoft User Number: 2655 Run Code: 2010-08-27T13:14:47 ID: Page 13 of 13