Loading...
10-0097 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00000097 -' Property Address: 55755 PEBBLE BEACH APN: 775-170-013- - - Application description: DWELLING - SINGLE FAMILY DETACHED - Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 417597 Applicant: T� Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION (-hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an ' rofessionals Code, and my License is in full force and effect. ` License Class: A, B, C27 License No.: 397169 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPE"11T Owner: WAYNE LUNAN 5840 FALCON ROAD WEST VANCOUVER B.C. ROLLING HILLS ESTATE, Contractor: JOHNSON CONSTRUCTION, P.O. BOX 2130 RANCHO MIRAGE, CA 9227 (760)776-1464 Lic. No.: 397169 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/01/10 0274 �Uii..0.1- 2010-.. -. CITY OF LA QUINTA FI; ANI ,-,E ^EPT_. ----------------------------------------------— WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: -I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided - for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1154122-2009 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if Ishout a owe ' ct to the workers' compensation provisions of Section �t 3700 of the Labor Code .sl aall forthwit comply with those provisions. f Date: l ��-`Applicant: i WARNING: FAILURE TO SECURE. WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to buildin �struction, and hereby authorize representatives of this county to enter upon the above-mentioned prop or in pection purposes. -. Date: d Signature (Applicant or Agent): Application Number . . . . . 10-00000097 ------ Structure Information 4648 SF SFD ----- Construction Type TYPE V, UNPROTECTED Occupancy Type DWELLG/LODGING/CONG <=10 Other struct info . CODE EDITION 2007/08 energy # BEDROOMS 3.00 FIRE SPRINKLERS NO GARAGE SQ FTG 825.00 PATIO SQ FTG 1945.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 4648.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE .00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 1752.50 Plan Check Fee 1139.13 Issue Date Valuation 417597 Expiration Date 12/28/10 Qty Unit Charge, Per Extension BASE FEE 639.50 318.00 3.5000 -------------------------------------------------------------- THOU BLDG 100,001-500,000 -------------- 1113.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 248.08 Plan Check Fee 62.02 Issue Date . . . . Valuation 0 Expiration Date 12/28/10 Qty Unit Charge Per Extension BASE FEE 15.00 4648.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 162.68 2770.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 55.40 1.00 15.0000 -------------------------- •-------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 12/28/10 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL LQPERMIT Application Number . . . . 10-00000097 Permit . . . MECHANICAL Additional desc . Permit Fee 152.50 Plan Check Fee 38.13 Issue Date . . . Valuation . . . 0. Expiration Date .. 12/28/10 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 ' 3.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 49.50 1.00 6.5000 EA MECH AH <=10K CFM 6.50 6.00 6.5000 EA 'MECH VENT FAN 39.00 -"----- ---- 0.... ._-._-6.5000-EA-MECH' ---------------------------------------------------------------------------- EXHAUST -HOOD---- -- __.........6.50 .._.... _.. _ _ -. Permit PLUMBING Additional desc . Permit Fee . . . . 261.00 Plan .Check Fee 65.25 Issue Date . . . . Valuation 0 Expiration Date 12/28/10 Qty Unit Charge Per Extension :._ BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 10.00 6.0000 EA PLB ROOF DRAIN 60.00 2.00 7.5000 EA. PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000, EA PLB LAWN SPRINKLER SYSTEM 9.00 12.00 .7500 EA PLB GAS PIPE >=5 9:00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4648 SF SINGLE FAMILY DWELLING. 825 SF GARAGE, 1945 SF PATIO. R-3 OCC. TYPE V -B CONSTRUCTION. 410 SF STUDIO IS NOT APPROVED AS A SLEEPING ROOM. 2007 CODES 2008 ENERGY. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, DRIVEWAY APPROACH and BBQ'S**2008 DIF ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 543.99 BLDG STDS ADMIN (SB1473) 17.00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 113.91 LQPERAIIT .r LQPERMIT Application Number 10-00000097 ---------------------------------------------------------------------------- Other.Fees . . . . .. DIF FIRE PROTECTION -.RES '140.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI)' - RES 41.76 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged -------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total -- 2429.08 .00 .00 2429.08 Plan Check Total 1304.53 500.00 .00 804.53 — _-._----- _—Ot er -Fee-"Tbta-------5191-66 _�-.__. _. —.-00----•-- . 00 .. -_....5191'."66 -._ ....... ......._.. _ _ Grand Total 8925.27 500.00 .00 8425.27 r uulctcv ID C&4 P.O. BOX 1504 APPLICATION ONLY Building ��'� �55 �Eb 6LE ..A�` /78-495 CALLE TAMPICO Address u/QUINTA, CALIFORNIA 92253 Owner ( .0^ WA 0 V t� VA 1i BUILDING: TYPE CONST. OCC. GRP. Mailing D 17S- (70 _ ?J Address G4640 f-_ALGOIJ r fl• A.P. Number w �dYlCOUVey 100q_Cj2j •,q1t(9 Legal Description e / Project Description N�6lJ /yq rh/`y Contractor h p7 - �,�A ) D`-' yam" s� ecce Addres A U a 3 " ��/ T 2�)77G—ts Sq. Ft.,f No. No. DIN. I Size TT/r/ I - Stories Units State Lic. & Classif. 13-(-� 3770 City Lic. # Arch., Engr., Designer S.-mbymm, P?Sf t( New] Add ❑ Alter ❑ Repair ❑ Demolition ❑ h -14. Address Tel. Ad Sol 94q % • C'ty Cf, ,,,4 Zi State 2 13 Lic. # LICENSED CONTRACTOR'S DECLARATION licensed under provisions of Chapter 9 (commencing with Section I hereby a '23�B 7000) of D' isusiness and Professions Code, and my license is in full force and effect. Z SIGNATURE OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a PERMIT AMOUNT permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis Plan Chk. Dep. for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects Plan Chk. Bal. the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do Const. the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds Mech. 0 or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of Electrical j proving that he did not build or Improve for the purpose of sale). Plumbingnn-in 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does U F LED) 4LUIU not apply to an owner of property who builds or improves thereon, and who contracts for such S.M.I. Grading projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Driveway Enc. Date owner Infrastructure WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. It CERTIFICATE OF EXEMPTION FROM TOTAL WORKERS' COMPENSATION INSURANCE REMARKS (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. r Date Owner ::, ti „+ 1i( ter: — NOTICE TO APPLICANT.' It, after making this Certificate of Exemption you should become ZONE: BY: Minimum Setback Distances: subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Rear Setback from Rear Prop.Line Lender's Name Side Street Setback from Center Line Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to Side Setback from Property Line expiration if work thereunder is suspended for 180 days. . I certify that I have read this application and state that the above information is correct. FINAL DATE INSPECTOR I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Issued by: Date Permit Signature of applicant Date Mailing Address Validated by: Validation: City, State, Zip WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/PID. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: P_GAMWesfStadium Date: May 5, 2010 Owner's Name: Wayne Lunan Phone No. 760-776-1464 Project Address: 55-755 Pebble Beach, LaQuinta Project Description: Single Family Dwelling APN: - 775-170-013 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 4,648 ' Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to ' on behalf of the owner/developer. Dated: May 5, 2010 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) , Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement N^-ote Number of Sq.Ft. 4648 Amount per Sq.Ft. $.47 Amount Collected $2,184.56 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Certificate issued by: Laurie Howard, Secretary III Signature: c-kx�� 4-6� aLk NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy.As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/certificate of compliance form updated 3-2007 3/9/07 MAR 05 2008 9:14 AM FR STEWART ESCROW LAQUIN71 5854 TO 919516598417 w RECORDING REQUESTED 6r: flew Century Title Company - Riverside Title ORDER NO.: 2362467" ESCROW NO.: 33GS1436-KY AND WHEN RECORDED MAIL TO: Wayne Lifnan 5840 Falcon Rd. West Vancouver, 6C CANADA V7W 1S3, DOC # 2006--0109388 02/14/2006 68-@@R Fee: I®.e0 Rage 1 of 2 DOC T Tax Paid, Recorded in Official Records CouSty.of Riverside Larry Y. Yard assessor, County Clerk & Recorder l �I� �Ii ilU l(11 �11� �1� l��I 111 full ll� llll s .-c. I$a I d I I sus 10"r~ GRANT HEED THE UNDERSIGNED GRAMMKS) OKLARE(S) that doatmwftry trarAW UX is $610.50 (County) 8.00 (Oty) ( X) Computed on full value of property Conveyed, or ( ) computed on foil value less rims or encumbrances remaining at time of sale ( X) City of La Quinta P.04/08 FOR A VALUABLE CONSIDERATION, receipt of which is hereby admowledged, Rita Cory, sole and separate party hereby GRAPIT(S)toWayne Lunan , an untuarried man the following described real property in the City of La Quints, County of Riverside, State of California: See legal description attached hereto and made a part hereof as Exhibit 'A' :V �G. .-.Pe . 3 Dated. Nevelt ben?; 2005 STATE OF rpPMA COUefTY OF On 03 SOS beim me -1 aHN verwrudly JW CO 7Y aeriW04 *' M (Of p ved to Nie On bm Of SaCltaday ewacm) to be the pasorgg-vvRoseV sub=bed IN the within i and admoMAedged m me ex the same tr►X!F! autliortie8 eapaei>at�, and chat by SigfwMn 0 irmuni t the paso%tpr the maty upon behdf of the persaeted, execuoe0 theirnaumeal WftNESS my hand ate � , SitjA2tY7! Grant DeeO — INOvidual (29D)10.04 Rita cots (00%k AanIn loStOMNwMAN NllRti-CALIFORNIA S • 0.1510220 LAS ANGELES COUWY tAr cam n. EVC- AVO.20.200tt r AFMk JOHN OHANNESIAN - NOTARY UBLtC-CAUFORNIA �. CCIASSL iIst0220 'c LAS ANGELES COUNTY, , My Comm. Ev. Aup: 28. EOoe. ;Tis am fa aftm naafi sup MAIL TAX STATEMENTS AS DIRECFW ABOVE Description: Riverside,CA Document -year DOCID 2006L109388 page: f of Order. 55755 Pebble Beach Comment: MAR'05 2008 9:14 AM FR STEWART ESCROW LAQUIN71 5854 TO 919516598417 P.05i08 EXHIBIT "A" LOT 13 OF TRACT 28397, IN THE CITY. OF LA QUINTA, AS SHOWN IN BOOK 218 OF MAPS AT PAGES 20 THROUGH 25 OF THE RIVERSIDE COUNTY RECORDS, TOGETHER WITH THAT PART OF LOT 12 OF SAID TRACT 25397, BEING OESCRIBED AS FOLLOWS: COMMENCING AT THE COMMON POINT BETWEEN LOTS 12.13. AND 32 OF TRACT 25397 SAID POINT.BEING THE "POINT OF BEGINNING". THENCE SOUTH 214718" EAST ALONG THE COMMON LINE BETWEEN LOTS 12 AND 13 OF SAID TRACT, A DISTANCE OF 156.73 FEET TOA POINT ON THE NORTH UNE OF PEBBLE BEACH ANDA POINT OF CURVATURE HAVING A RADIAL BEARING OF NORTH 14°00'17" WEST; THENCE NORTH 28"36'50" WEST, A DISTANCE OF 156.41 FEET TO A POINT ON THE NORTH UNE OF LOT 12; THENCE NORTH 64"07'351• EAST ALONG THE NORTH UNE OF LOT 12, A DISTANCE OF 20.00 FEET TO THE "POINT OF BEGINNING". Page 1 Description: Riverside, CA Document- year DOCID 2006109388 Page: 2 of z Order. 55755 Pebble Beach Comment v' PGA WEST-. RESIDENTIAL ASSOCIATION, INC. February 16, 2010 Mr. Wayne Lunan 5840 Falcon Road West Vancouver, BC. V7W 1S3 Canada Re: Custom Home to be built at 55-755 Pebble Beach, La Quinta Dear Mr. Lunan, The Architectural Committee welcomes your custom home development plan and has reviewed your Architectural Variance Submittal package consisting of preliminary plans and renderings of your proposed new residence. Based on the Architectural. Guidelines and the Homeowner's Association CC&R's, your request is approved. Upon receiving your. -City. of La Quinta approved set of drawings and permit, please provide us with two copies for our files ' and final review. In the interim, if there are any other pending items, they can be finalized within this time frame. f. As Steve Herthel mentioned, last week he informed your contractor of the possible underground storm drain lines on your lot and the HOA access setback requirement on the lakeside of your property. This was for his information and to address if necessary. . Please contact me or Barbara Van Fleet if you have any questions. Sincerely, K ly McGalliard t Operations Manager For the Architectural Committee KM/bvf Cc: Architectural Committee s 54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 5- 0 Developer: fNATYi1(2-- Tract No.: Tract Name: _ Lot No.(s): �I D'� Z ( v — O Address(s): �5 Z S 5 l/' ZJ�5`3 �� /l Phone Number: (76&) The following are the requirements for Public Works Clearance to authorize issuance ofbuil Idin ermit from th Building & Safety Department: - ECEIVED CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW MAY 2 7 2010 r ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #4#2, #3, #5 &#7 BELOW Development Services ❖ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). Z If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. 2.Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils �/ Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. -'3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. vd� Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. -5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. -I. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: 6 RECEIVEDPublic Works Distribution: (_6) -Green Sheet to Building &Safety , ( ) Green Sheet to Planning Department ,SUN 11 2010 Declined for approval for reason(s) as follow(s), please correct and resubmit: DedelopC ent.5erViC-0 T:\Checklists - Forms & Applications\Fors & Applications\GREEN SHEET cover 9 PM10 less than 1 Acre Revised 9-25-09.doc ti. City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (<1 acrehot or Infill Proiect) Project Information Project Contractor: 2Lu`' � C� �S �zey✓ Project Phase (check one) Construction Demolition Project Name:yv 4—,,/ Project Tract/Lot Numbers: /�P.A/ "i% 5-'- f 70 — Project Street Address: 55-5---%5-5-- �24 6 Total Acres in Active Construction (<1 acre per. Lot): /J1 c Anticipated Start Date: Co / �S/ �o Anticipated Completion Date: 3 / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and noon-7business hours. Name: fJ Title: Company Name: Mailing Address: Cit , State, ZIP Code: C. vZ? v Primary Phone #: Fax M 24 Hour Emergency Phone#: '7 LG c 7 7-- v Cell Phone #: Email Address:;K Ain- 01 eq - :PM:10 Certificate #: n l 1 A-77114 S` �^' �G(�9�.�—. 5 7 �7 G1-3 M The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or an ty initiated abatement activities. Signature of P wner or Authorized Representative Date TAChecklists - Forms 6 Applications\Forrns & Applications\GREEN SHEET cover 6 PM10less than 1 Acre Revised 9-25-09.doc arcnitecture, Interiors, Space and land Planning, and Structural Design Principle; Charles D. Garland, Archltert Aswdate: Main Cardenas, £nglneer In Training 8 November 2010 The City of La Quinta Department of Building and Safety 78.495 Calle Tampico La Quints, CA 92253 Project: The Single Family Residence for: Wayne Lunan 55-755 Pebble Beach PGA West La Quinta, California Regarding: Project Structural Observation To Whom It May Concern, I am a licensed architect in the state of California and the Structural Designer of. Record for the project noted above. On 3 November 2010 1 made CBC mandated structural construction observations and found the foundation, the foundabon!framing interface and the framing to be in substantial conformance with the structural design intent of the structural construction documents of record for the project. During my observations I noted only minor nailing, blocking and strapping issues which were addressed to my satisfaction on Friday 4 November 2010 - Therefore, I hereby certify that the noted project is in substantial conformance with the structural design intent of the structural design construction documents of record and stands ready to wrap and receive the City's final. framing Inspection. If you have anyqu mments regarding these issues or any other issue please do not hesitate in contacting my firm. — D AS Si • No. C11991 Charles a Architect 10!31!?.011 4&10F CAL����� 74-991 Joni Drive, Suite 9, Palm Desert, CA 92260 a ' o�Fi nye: (760) 340.3528 o Facsimile: (760) 340-3728 71-.780 San Jacinto Dr. Ste. E2; Rancho Mirage, Ca. 92270 ph. (760) 834-8860 fax (76 Letter of Transmittal To: City of La Quinta Today's Date: 6-21-10 78-495 Calle Tampico City Due Date: 6-30-10 La Quinta, CA 92253 Project Address: 55-755 Pebble Beach Drive Attn: Phillip Plan Check #: 10-97 Submittal: ❑ 15l ® 4 t ❑ 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: ® By Messenger ❑ Includes: # Of Descriptions: ® Copies: ® ❑ ® Structural Plans ❑ Struct. Calcs ❑ El Truss Calculations ❑ Soils Report ® 1 Structural Comment List ® 1 Redlined Structural Plans ® 1 Redlined Structural Calcs ❑ Redlined Truss Calcs ❑ Redlined Soils Reports Comments: Structural content is approvable. This Material Sent for: ❑ Your Files ❑ Your Review ❑ Checking Other: ❑ By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ By Mail (Fed Ex or UPS) Includes: # Of Copies: ® 1 ® 1 ® 1 El El El 11 El ❑ Your Pickup Descriptions: Revised Structural Plans Revised Struct. Calcs Revised Truss Calcs Revised Soils Report Approved Structural Plans Approved Structural Calcs Approved Truss Calcs Approved Soils Report Other: ® Per Your Request ❑ Approval ❑ At the request of: BUILDING ENERGY ANALYSIS REPORT PROJECT: LUNAN RESIDENCE 55-755 PEBBLE BEACH LA QUI NTA, CA 92253 Project Designer: Santamaria Design Int'I. 41-875 Boardwalk Suite 208 Palm Desert, Ca 92211 (760) 568 2800` Report Prepared by: GLS Architecture Group 74-991 Joni Dr #9 Palm Desert, California 92260 -D APR 14 2010 _ :S CITY OF Qu . BY: BUILDING &SAFE UINTA APPROVETY D Job Number: VEE FOR CONST RUCTION DA f e Date: eY 4/13/2010. The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy. Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. r TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 15 EnergyPro 5.0 by EnergySoft Job Number. ID: User Number. 5553 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1411312010 Date Project Address 55-755 PEBBLE BEACH LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,238 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features see Part 2 of 5 Status Wall Wood Framed R-21 4,570 New Door Opaque Door None 24 New Roof Wood Framed Attic R-38 4,227 Radiant Barrier New Slab Unheated Slab -on -Grade None 4,238 Perim = 0' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Left (SVV) 276.0 0.400 0.35 none none Bug Screen New Rear (NKK 570.6 0.400 0.35 none none Bug Screen New Right (NE) 195.6 0.400 0.35 none none Bug Screen New Front (SE) 313.9 0.400 0.35 none none Bug Screen New Front (SE) 3.0 0.510 0.66 none none Bug Screen New Skylight 2.5 0.400 0.35 none none None New Skylight 2.5 0.400 0.35 none none None New Skylight 2.5 0.400 0.35 none none None New Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 97% AFUE Split Air Conditioner 16.5 SEER No Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Undefined System Ducted Ducted Attic, Roof Ins 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Large Gas 75 0.78 Kitchen Pipe Ins New EnergyPro 5.0 by Energ Soft User Number: 5553 Run Code: 2010-0413712:15:2 ID: Page 3 of 15 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1411312010 Date Project Address 55-755 PEBBLE BEACH LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,238 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavit ft) Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New Skylight 0.5 0.300 0.30 none none None New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.0 by EnergySoft User Number: 5553 Run Code: 2010-0413712:15:2 ID: Page 4 of 15 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/13/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System A O Smith Water Products FPSH-75 is a non-NAECA large storage gas water heater. Verify DHW details. The Roof R-38 Roof Cathedral Reflectance= 0.30,.Emittance = 0.75 shall be rated and labeled by the Cool Roof Rating Council in accordance with Section 10-113 of the standards. The Roof R-38 Roof Cathedral includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. The Cooling System Carrier Corp. 24ACB648A30 includes credit for a 13.1 EER Condenser. A certified HERS rater must field verity the installation of the correct Condenser. The HVAC System Undefined System incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Undefined System includes verified duct systems that have air leakage to outside conditions equal to or less than 25 ctm. HERS field verification for ducts in conditioned space and duct leakage is required. EnergyPro 5.0 by Ene Soft User Number: 5553 Run Code: 2010-0413712:15:2 ID: Page 5 of 15 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date LUNAN RESIDENCE ❑ Multi Family ❑ Existing+ Addition/Alteration 4/13/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 1.61 2.05 -0.44 Space Cooling 64.88 57.06 7.82 Fans 12.46 17.74 -5.29 Domestic Hot Water 11.06 7.77 3.28 Pumps 0.00 0.00 0.00 Totals 90.00 84.62 5.38 Percent Better Than Standard: 6.0 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 1,531 317 Fuel Available at Site: Propane (Sw) 1,460 276 Raised Floor Area: 01 (NM 1,508 571 Slab on Grade Area: 4,238 (NE) 1,454 196 Average Ceiling Height: 12.0 Roof 4,238 12 Fenestration Average U-Factor: 0.40 TOTAL: 1.371 Average SHGC: 0.35 Fenestration/CFA Ratio: 32.3% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GLS Architecture Group 74-991 Joni Dr #9 4/13 010 Address Name G.2` City/State/ZipCity/State/Zip Palm Desert, California 92260 Phone (760) 340 3528 i ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Santamaria Design Int'l. Address 41-875 Boardwalk Suite 208 Name Antonio Santamaria—�—�� 3 • �( City/State/Zip Palm Desert, Ca 92211 Phone (760) 568 2800 Signed License # Date EnemvPro 5.0 by EnemySoft User Number. 5553 RunCode: 2010-04-13T12:15:2 /D: Page 6 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411312010 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity7Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 860 0.069 R-21 225 90 New 4.3.1-A6 Wall 891 0.069 R-21 315 90 New 4.3.1-A6 Wall 934 0.069 R-21 45 90 New 4.3.1-A6 Wall 1,144 0.069 R-21 135 90 New 4.3.1-A6 Door 24 0.500 None 135 90 New 4.5.1-A4 Roof 4,227 0.025 R-38 270 0 New 4.2.1-A21 Slab 4,238 0.730 None 0 180 New 4.4.7-A1 Wall 324 0.069 R-21 225 90 New 4.3.1-A6 Wall 47 0.069 R-21 315 90 New 4.3.1-A6 Wall 324 0.069 R-21 45 90 New 4.3.1-A6 Wall 47 0.069 R-21 135 90 New 4.3.1-A6 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 67.5 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 2 Window 48.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 3 Window 4.5 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 4 Window 40.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 5 Window 1 40.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 6 Window 40.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 7 Window 24.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 8 Window 3.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 9 Window 60.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 10 Window 76.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 11 Window 2.3 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 12 Window 2.3 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 13 Window 24.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 14 Window 72.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 15 Window 31.5 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 16 Window 5.3 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len Hot 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 JBug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.0 by EnergySoft User Number. 5553 RunCode: 2010-0413712:15:2 /D: Page 7 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/13/2010 OPAQUE SURFACE DETAILS Surface Ll- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area LI -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 180.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 18 Window 5.3 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 19 Window 31.5 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 20 Window 6.8 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 21 Window 6.0 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 22 Window 5.1 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 23 Window 4.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 24 Window 4.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 25 Window 12.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 26 Window 112.5 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 27 Window 4.7 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 28 Window 19.2 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 29 Window 4.7 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 30 JWndow 1 18.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 31 JMndow 1 4.5 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 32 JMndow 1 12.3 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P -D (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Len H t LExt Left Fin Right Fin RExt Dist Len H t Dist I Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bua Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 JBug Screen 0.76 32 IBug, Screen 1 0.76 EnergyPro 5.0 by EnergySoft User Number., 5553 RunCode: 2010-0413712:15:2 /D: Page 8 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone O Multi Family ❑ Existing+ Addition/Alteration Date 1411312010 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status GlazingType Location/Comments 33 Window 4.5 0.400 NFRC 0.35. NFRC 135 New 2008 PRESCR. WDW P-D 34 Window 75.0 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 35 Window 54.0 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 36 Window 75.0 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 37 Window 4.5 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 38 Wndow 3.0 0.510 NFRC 0.66 NFRC 135 New PITS-CORN -GLASS BLOCK 8 39 Window 24.0 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 40 Window 5.1 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P-D 41 Skylight 2.5 0.400 NFRC 0.35 NFRC 270 New 2008 PRESCR. WDW P-D 42 Skylight 2.5 0.400 NFRC 0.35 NFRC 270 New 2008 PRESCR. WDW P-D 43 Skylight 2.5 0.400 NFRC 0.35 NFRC 270 New 12008 PRESCR. WDW P-D 44 ISkylight 0.5 0.300 NFRC 0.30 NFRC 270 New I SOLA TUBE INTL. 45 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLA TUBE INTL. 46 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLA TUBE INTL. 47 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLA TUBE INTL. 48 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLATUBE INTL. (1) Ll-Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Len H t LExt Left Fin Ri ht Fin RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 None 1.00 42 None 1.00 43 None 1.00 44 None 1.00 45 None 1.00 46 None 1.00 47 None 1.00 48 INone 1.00 EnergyPro 5.0 by EnergySoft User Number: 5553 RunCode: 2010-04-13T12:15:2 ID: Page 9 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/13/2010 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLATUBE INTL. 50 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLA TUBE INTL. 51 Skylight 0.5 0.300 NFRC 0.30 NFRC 270 New SOLA TUBE INTL. 52 Window 6.0 0.400 NFRC 0.35 NFRC 225 New 2008 PRESCR. WDW P -D 53 Window 6.0 0.400 NFRC 0.35 NFRC 2251 New 2008 PRESCR. WDW P -D 54 Window 59.5 0.400 NFRC 0.35 NFRC 315 New 2008 PRESCR. WDW P -D 55 Window 6.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 56 Window 6.0 0.400 NFRC 0.35 NFRC 45 New 2008 PRESCR. WDW P -D 57 Window 59.5 0.400 NFRC 0.35 NFRC 135 New 2008 PRESCR. WDW P -D (1) LI -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hanq Left Fin Ri ht Fin Len Hat LExt RExt Dist Len Hat Dist I Len H t 49 None 1.00 50 None 1.00 51 None 1.00 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 57 Bug Screen 0.76 EnergyPro 5.0 by EnergySoft User Number: 5553 RunCode: 2010-04-13T12:15:2 /D: Pae 10 of 15 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name LUNAN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411312010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built Undefined System S-4238 4,238 50,856 TOteIS 4,238 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Undefined System 3 Central Furnace 97% AFUE Split Air Conditioner 16.5 SEER No Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status Undefined System Ducted Ducted Attic, Roof Ins 8.0 m New WATER HEATING SYSTEMS S stem Name City. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A O Smith Water Products 2 Large Gas Kitchen Pipe Ins 80,000 75 0.78 0.00% 0.0 New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E Ti a ¢ Hot Water Piping Length ft o U) — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5.0 by EnergySoft User Number: 5553 Run Code: 2010.04-13T12:15:2 ID: Pae 11 of 15 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name LUNAN RESIDENCE Date 1411312010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no areater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 (e)l A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e uipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)l B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.0 by EnergySoft User Number: 5553 Run Code: 2010-0413712:15:23 /D: Page 12 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date LUNAN RESIDENCE 4/13/2010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.0 by EnergySoft User Number., 5553 RunCode: 2010-0413712:15:23 /D: Page 13 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date LUNAN RESIDENCE 1411312010 §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five wafts of power as determined according to §130 d . §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro5.0 by EnergySoft User Number: 5553 RunCode: 2010-04-13T12:15:23 /D: Page 14 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name LUNAN RESIDENCE Date 4/13/2010 System Name Undefined System Floor Area 4,238 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 COIL CFM Total Room Loads 1,138 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 25,000 68,363 3,446 1,252 53,506 Total Output Btuh 75,000 0 Output Btuh/s ft 17.7 0 0 Cooling System 0 0 Output perSystem 48,500 0 0 0 0 Total Output Btuh 145,500 0 3,446 0 Total Output Tons 12.1 0 0 Total Output Btuh/s ft 34.3 Total Output s ft/Ton 349.5 1 68,363 1 53,506 Air System CFM perSystem 585 HVAC EQUIPMENT SELECTION Airflow cfm 1,755 Carrier Corp.24ACB648A30 105,387 0 75,000 Airflow cfm/s ft 0.41 Airflow cfm/Ton 144.7 Outside Air % 0.0% Total Adjusted System Output 105,387 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 75,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF Outside Air 0 cfm Supply Fan 1,755 cfm 70 OF 70 OF 110 OF Heating Coil 110 OF _ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/51 Outside Air 0 cfm 78 / 51 OF OF 78/52°F 22/20°F tom', Supply Fan Cooling Coil 22 / 20 OF 1,755 cfm 10.7% ROOM 78 ! 51 OF EnergyPro5.0 by EnergySoft User Number: 5553 Run Code: 2010-0413712:15:23 ID: Page 15 of 15 BUILDING ENERGY ANALYSIS REPORT r PROJECT: LUNAN- RESIDENCE'Sstudio, 55-755 PEBBLE BEACH LA QUI NTA, CA 92253 Project Designer: Santamaria Design Int'I. 41-875 Boardwalk Suite 208 Palm Desert, Ca 92211 (760) 568 2800 Report, Prepared 'by:, GLS Architecture Group 74-991 Joni Dr #9 Palm Desert, California 92260 '(760) 340 3528 E CEI[VED APR 14 2010 CITY ®� s. LA QUINT�A BUILDING &SAFETY DEPT. - BY: o um er: APPROVED } . FOR CONSTRUCTION Date: oarE_ BY/ '4/13/2010 !�" 77 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report..This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential'2008 Building Energy Efficiency Standards." This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.0 by EnergySoft User Number., 5553 • Run Code: 2010-04-13T12:19:4 /D:. i TABLE OF CONTENTS Cover Page 1 .Table of Contents' 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 EnergyPro 5.0 by EnergySoft Job Number:' ID: - User Number. 5553 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name LUNAN RESIDENCE'S studio Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration 1411312010 Date . Project Address 55-755 PEBBLE BEACH LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 410 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features-- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ftp Features see Part 2 of 5 Status Wall Wood Framed R-21 862 Ext=R-4.0 New Door Opaque Door Insul 24 New Roof Wood Framed Attic R-49 410 Radiant Barrier New Slab Unheated Slab -on -Grade None 410 Perim = 0' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front (NE) 96.0 0.340 0.33 none none Bug Screen New Left (SE) 18.0 0.340 0.33 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 12.00 HSPF Split Heat Pump 25.0 SEER No Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value . Status Undefined System Ductless /with Fan Ductless n/a n/a New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.58 Kitchen Pipe Ins New EneqjyPro 5.0 by EnergySoft User Number.' 5553 RunCode: 2010-04-13T12:19:4 ID: Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name LUNAN RESIDENCE'S studio Building Type m Single Family ❑ Addition Alone I 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/13/2010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-49 Roof Cathedral Reflectance = 0. 30, Emittance = 0.75 shall be rated and labeled by the Cool Roof Rating Council in accordance with Section 10-113 of the standards. The Roof R-49 Roof Cathedral includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. Enem yPro5.0 byEnergySoft User Number: 5553 Run Code: 2010-04-13T12:19:4 ID: Page 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date LUNAN RESIDENCE'S studio ❑ Multi Family ❑ Existing+ Addition/Alteration 4/13/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2- r ' Space Heating 2.63 0.99 1.64 Space Cooling 87.44 83.91 3.53 Fans 18.76 23.46 -4.70 ' Domestic Hot Water 68.18 68.18 0.00 Pumps 0.00 0.00 0.00 Totals 177.01 176.54 0.47 - Percent Better Than Standard: 0.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ekt. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 289 96 Fuel Available at Site: Propane (SE) 237 18 Raised Floor Area: 0 (SM 237 0 Slab on Grade Area: 410 (NM 237 0 Average Ceiling Height: 10.5 Roof 410 0 Fenestration Average U -Factor: 0.34 TOTAL: 114 Average SHGC: 0.33 Fenestration/CFA Ratio: 27.8% . REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company GLS Architecture Group , 74-991 Joni Dr #9 4/132 10 Address Name 4signed Cit /State/Zi Palm Desert, California 92260 Phone (760) 340 3528 Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit'application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Santamaria Design Int'l. Address 41-875 Boardwalk Suite 208 Name Antonio Santamaria City/State/Zip Palm Desert, Ca 92211 Phone (760) 568 2800 Signed License # Date EneMVPro 5.0 bV EnemVSoft User Number: 5553 RunCode: 2010-04-13T12:19:4, ID: Pa e 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name LUNAN RESIDENCE'S studio Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411312010 OPAOUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 213 0.054 R-21 4 None 225 90 New 4.3.1-A6 Door 24 0.500 Insul 225 90 New 4.5.1-A3 Wall 237 0.054 R-21 4 None 315 90 New 4.3.1-A6 Wall 193 0.0541R-21 4 None 45 90 New 4.3.1-A6 Wall 219 0.054 R-21 4 None 135 90 New 4.3.1-A6 Roof 410 0.019 R-49 0 0 New 4.2.1-A23 Slab 410 0.730 None 0 180 New 4.4.7-A 1 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 48.0 0.340 NFRC 0.33 NFRC 45 New Andersen Permashield 2 Window 48.0 0.340 NFRC 0.33 NFRC 45 New Andersen Permashield 3 Window 4.0 0.340 NFRC 0.33 NFRC 135 New Andersen Permashield 4 Window 10.0 0.340 NFRC 0.33 NFRC 135 New Andersen Permashield 5 Window 4.0 0.340 NFRC 0.33 NFRC 135 New Andersen Permashield (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.761 1 5 Bug Screen 0.76 EnergyPro 5.0 by EnergySoft User Number. 5553 RunCode: 2010-0413712:19:4 ID: Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name LUNAN RESIDENCE'S studio Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1411312010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built Undefined System S-410 410 4,305 Totals 4101 0 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Undefined System 1 Split Heat Pump 12.00 HSPF Split Heat Pump 25.0 SEER No Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status Undefined System Ductless / with Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E E E w o_ Hot Water Piping Length ft o 16 Q — System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ Enemyprpij.0 b EnemySoft User Number.' 5553 RunCode: 2010-04-13T12:19A ID: Pae 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name LUNAN RESIDENCE'S studio Date 1411312010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent LI -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine Iines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro5.0 by EnergySoR User Number: 5553 Run Code: 2010-04-1 3 71 2:19:45 ID: Page 8 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date LUNAN RESIDENCE'S studio 1411312010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro5.0 by EnergySoft User Number: 5553 Run Code: 2010-04-13T12:19:45 /D: Page 9of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date LUNAN RESIDENCE'S studio 1411312010 §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro5.0 by EnergySoff User Number: 5553 RunCode: 2010-04-13T12:19:45 /D: Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date LUNAN RESIDENCE'S studio 4/13/2010 System Name Floor Area Undefined System 410 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 1 COIL COOLING PEAK COIL HTG. PEAK Heating System Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Output per System 16,000 Total Output Btuh 16,000 Output Btuh/s ft 39.0 Cooling System Output per System 12,000 Total Output Btuh 12,000 Total Output Tons 1.0 Total Output Btuh/s ft 29.3 Total Output s ft/Ton 410.0 Air System CFM per System 400 HVAC EQUIPMENT SELECTION Airflow cfm 400 FUJITSU-12RL-ASU9RL Airflow cfm/s ft 0.98 Airflow cfm/Ton 400.0 aoo cfm Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time 26 OF 70 OF 72 OF 95 OF �.` Outside Air 0 cfm Supply Fan Heating Coil AL 400 cfm 70 OF CFM Sensible Latent CFM Sensible 357 8,661 1,016 204 5,469 0 0 0 0 0 0 0 0 0 0 744 -744 0 0 9,405 1,016 1 4,725 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 78/63°F 80/64°F 55/54°F 10,4501 01 1 9,9931 10,4501 0 19,993 Aug 3 PM Jan 1 AM 95 OF ROOM( 70 OF Outside Air 0 cfm Supply Fan Cooling Coil 55 / 54 OF aoo cfm 44.1% ROOM 78163 OF 78 / 63 OF EnergyPro5.0 by EnergySoff User Number: 5553 RunCode: 2010.0413712:19:45 /D: Page 11 of 11 BUILDING ENERGY ANAL PROJECT: Lunan Residence 55-755 Pebble Beach La Quinta, CA 92253 REPORT tt © d �« Project Designer: Santamaria Design Int'I. CITY OF LA QUANTA 71-780 San Jacinto, Suite 1�- BUILDING &SAFETY DEPT. Rancho Mirage, CA 92270 ����®��� (949) 456-9769 FOR CONSTRUCTION Re ort Pre ared b : , DA OS 20'Z --BY �� P P Y .` Tim Scott`:"'"..:_(, --0-: ... _•. , Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 RIFI Job Number: Date: 1/4/2012 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 1 4 0 0 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 18 Room Heating Peak Loads 20 Room Cooling Peak Loads 22 EnergyPro 5.1 by EnergySoft Job Number. ID: User Number: 6712 • • 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 Project Address 55-755 Pebble Beach La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,648 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST IZI Yes ❑ No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 4,637 Radiant Barrier Cool Roof New Wall Wood Framed R-21 4,091 New Door Opaque Door None 40 New Slab Unheated Slab -on -Grade None 4,648 Perim = 621' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Skylight 0.6 0.300 0.30 none none None New Skylight 0.6 0.300 0.30 none none None New Skylight 0.6 0.300 0.30 none none None New Skylight 0.6 0.300 0.30 none none None New Skylight 0.6 0.300 0.30 none none None New Skylight 0.6 0.300 0.30 none none None New Skylight 2.5 0.540 0.31 none none None New Skylight 2.5 0.540 0.31 none none None New Skylight 2.5 0.540 0.31 none none None New Right (NE) 66.2 0.450 0.22 none none Bug Screen New Right (NE) 160.5 0.450 0.22 8.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.2 SEER Setback New 1 Split Heat Pump 9.00 HSPF Split Heat Pump 25.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 New AC -4 Ductless /with Fan Ductless n/a n/a New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 2 Instant Gas 1 0.85 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Pe e 3 of 29 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 Project Address 55-755 Pebble Beach La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,648 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Right (NE) 4.5 0.450 0.22 10.0 none Bug Screen New Front (SE) 33.0 0.450 0.22 10.0 none Bug Screen New Front (SE) 203.4 0.450 0.22 8.0 none Bug Screen New Front (SE) 71.2 0.450 0.22 4.0 none Bug Screen New Front (SE) 4.2 0.720 0.59 6.0 none Bug Screen New Left (SW 76.5 0.450 0.22 4.0 none Bug Screen New Left (SIM 120.0 0.450 0.22 5.0 none Bug Screen New Left (SK9 6.0 0.450 0.22 none none Bug Screen New Left (SIAq 67.5 0.450 0.22 10.0 none Bug Screen New Rear (NIM 6.0 0.450 0.22 none none Bug Screen New Rear (Nt9 285.4 0.450 0.22 4.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04T11:30:56 ID: Page 4 of 29 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family• ❑ Existing+ Add ition/Alte ration Date 1/4/2012 Project Address 55-755 Pebble Beach La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,648 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (NIA 14.8 0.450 0.22 10.0 none Bug Screen New Rear (NKK 180.0 0.450 0.22 16.0 none Bug Screen New Rear (NKK 76.0 0.450 0.22 8.0 none Bug Screen New Rear (NK9 4.2 0.720 0.59 6.0 none Bug Screen New Front (SE) 18.0 0.450 0.22 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING (fit . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 /D: Pe e 5 of 29 • 0 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lunan Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 276.0 ft' Covered Slab Floor, 3.500" thick at Residence HIGH MASS Design - Verify Thermal Mass: 3,962. 0 ft2 Exposed Slab Floor, 3.500" thick at Residence HIGH MASS Design - Verify Thermal Mass: 50.0 ft2 Covered Slab Floor, 3.500" thick at Studio HIGH MASS Design - Verify Thermal Mass: 360.0 ft2 Exposed Slab Floor, 3.500" thick at Studio The Roof R-38 Roof Attic Reflectance = 0. 30, Emittance = 0.75 shall be rated and labeled by the Cool Roof Rating Council in accordance with Section 10-113 of the standards. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION ' Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System New HVAC includes credit for a 11.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System, The HVAC System HVAC incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System 1 Ton Fujitsu includes credit for a 14.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System AC -4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. E-nemvPro 5.1 by EneMySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 6 of 29 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lunan Residence ❑ Multi Family ❑ Existing+Addition/Alteration_ 1/4/2012 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.76 8.89 -4.13 Space Cooling 54.31 48.35 5.97 Fans 10.78 14.89 -4.11 ' Domestic Hot Water 7.85 5.40 2.45 Pumps 0.00 0.00 0.00 Totals 77.71 77.53 0.18 Percent Better Than Standard: 0.2 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SE) 135 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SE) 1,593 330 Fuel Available at Site: Natural Gas (SM 1,117 270 Raised Floor Area: 0 (N►M 1,625 566 Slab on Grade Area: 4,648 (NE) 1,194 231 Average Ceiling Height: 11.4 Roof 4,648 11 Fenestration Average U -Factor: 0.45 TOTAL: 1,409 Average SHGC: 0.22 Fenestration/CFA Ratio: 30.3.% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and'Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complet . Documentation Author Company Scott Design and Title 24, Inc, 1/4/2012 Address 77-085 Michigan Drive Name Tim Scott &—k' City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Santamaria Design Intl. Address 71-780 San Jacinto, Suite F-2 Name City/State/zip Rancho Mirage, CA 92270 Phone (949) 456-9769, Signed License # Date EnerovPro 5.1 by Ene Soft user Number: 6712 RunCode: 2012-01-04711:30:56 ID: Pae 7 of 29 • 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 OPAQUE SURFACE DETAILS Surface Type Area LlInsulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 4,227 0.026 R-38 270 0 New 4.2.1-A9 Main Residence Wall 749 0.069 R-21 45 90 New 4.3.1-A6 Main Residence Wall 1,057 0.069R-21 135 90 New .4.3. 1-A6 Main Residence Door 20 1.450 None 135 90 New 4.5.1-A1 Main Residence Wall 594 0.069 R-21 225 90 New 4.3.1-A6 Main Residence Wall 856 0.069 R-21 315 90 New 4.3.1-A6 Main Residence Slab 276 0.730 None 0 180 New 4.4.7-A1 Main Residence Slab 3,962 0.730 None 0 180 New 4.4.7-A1 Main Residence Roof 410 0.026 R-38 0 0 New 4.2.1-A9 Studio Wall 214 0.069 R-21 45 90 New 4.3.1-A6 Studio Wall 186 0.069 R-21 135 90 New 4.3.1-A6 Studio Wall 233 0.069 R-21 225 90 New 4.3.1-A6 Studio Door 20 1.450 None 225 90 New 4.5.1-A1 Studio Wall 203 0.069 R-21 315 90 New 4.3.1-A6 Studio Slab 50 0.730 None 0 180 New 4.4.7-A1 Studio Slab 1 3601 0.730 1 None 1 01 180 New 4.4.7-A1 IStudio FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 1 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Main Residence 2 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Main Residence 3 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New " Solatube Skylight Main Residence 4 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Main Residence 5 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Main Residence 6 Skylight 0.6 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Main Residence 7 Skylight 2.5 0.540 NFRC 0.31 NFRC 270 New Bristol Skylight Main Residence 8 Skylight 2.5 0.540 NFRC 0.31 NFRC 270 New Bristol Skylight Main Residence 9 Skylight 2.5 0.540 NFRC 0.31 NFRC 270 New Bristol Skylight Main Residence 10 Window 4.6 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 11 Window 19.0 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 12 Window 18.0 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 13 Window 4.6 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 14 Window 112.5 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 15 Window 12.0 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 16 Window 4.01 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 None 1.00 7 None 1.00 8 None 1.00 9 None 1.00 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 9.0 12.5 8.0 0.1 8.0 8.0 15 Bug Screen 0.76 16 JBug Screen 0.76 EnemyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 8 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID TvDe I Area U -Factor SHGC Azm Status Glazing Type Location/Comments- 17 Window 4.0 0.450 NFRC 0.22 1 NFRC 45 New Heritage Windows Main Residence 18 Window 4.5 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Main Residence 19 Window 4.5 0.450 NFRC 0.22 NFRC 135 New Herita a Windows Main Residence 20 Window 74.7 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 21 Window 54.0 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 22 Window 58.9 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 23 Window 74.7 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 24 Window 4.5 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 25 Window 12.3 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 26 Window 4.2 0.720 NFRC 0.59 NFRC 135 New Glass Block Main Residence 27 Window 24.0 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Main Residence 28 Window 24.0 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 29 Window 40.0 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 30 Window 40.0 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 31 JMndow 40-01 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 32Window 1 4.51 0.450 NFRC 0.22 NFRC 2251 New Heritage Windows Main Residence (1) Ll -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Hot Wd Len H t LExt RExt Dist I Left Fin Ri ht Fin Len Hot I Dist Len I H t 17 Bug Screen 0.76 18 Bug Screen 0.76 1.5 3.0 10.0 0.1 10.0 10.0 19 Bug Screen 0.76 1.5 3.0 10.0 0.1 10.0 10.0 20 Bug Screen 0.76 9.0 8.6 8.0 0.1 8.0 8.0 21 Bug Screen 0.76 9.0 6.0 8.0 0.1 8.0 8.0 22 Bug Screen 0.76 2.31 25.5 4.0 0.1 4.0 4.0 23 Bug Screen 0.76 9.0 8.3 8.0 0.1 8.0 8.0 24 Bug Screen 0.76 1.5 3.0 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 3.5 3.5 4.0 0.1 4.0 4.0 26 Bug Screen 0.76 6.0 0.7 6.0 0.1 6.0 6.0 27 Bug Screen 0.76 8.0 3.0 10.0 0.1 10.0 10.0 28 Bug Screen 0.76 8.0 3.0 4.0 0.1 4.01 4.0 29 Bug Screen 0.76 6.05.0 5.0 0.1 5.0 5.0 30 Bu Screen 0.76 8.0 5.0 5.0 0.1 5.0 5.0 31 Bu Screen 0.76 8.0 5.0 5.0 0.1 5.0 5.0 32 Bu Screen 0.76 1.5 3.0 4.0 0.1 4.0 4.0 EnemyPro 5.1 bv EnemySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 9 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Type Area Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 33 Window 48.0 0.450 NFRC 0.22 1 NFRC 225 New Heritage Windows Main Residence 34 Window 6.0 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 35 Window 67.5 0.450 NFRC 0.22 NFRC 225 New Heritage Windows Main Residence 36 Window 6.0 0.450 1 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 37 Window 2.3 0.450 NFRC 0.22 NFRC 315 New I Heritage Windows Main Residence 38 Window 2.3 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 39 Window 2.3 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 40 Window 31.5 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 41 Window 1.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 42 Window 1 1.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 43 Window 1.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 44 Window 58.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 45 Window 180.0 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 46 Window 1.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 47 Window 1.7 0.450 NFRC 0.22 NFRC 315 New Heritage Windows 1 Main Residence 48Window 1.71 0.450 NFRC 0.22 NFRC 315 New Heritage Windows I Main Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Hot Wd Len I H t LExt I RExt Dist Left Fin Ri ht Fin Len Hot I Dist Len H t 33 Bug Screen 0.76 8.0 6.0 4.01 0.1 4.01 4.0 34 Bug Screen 0.76 35 Bug Screen 0.76 9.0 7.5 10.01 0.1 10.0 10.0 36 Bug Screen 0.76 37 Bug Screen 0.76 1.5 1.5 4.01 0.1 4.0 4.0 38 Bug Screen 0.76 1.5 1.5 4.0 0.1 4.0 4.0 39 Bug Screen 0.76 1.5 1.5 4.01 0.1 4.0 4.0 40 Bug Screen 0.76 9.0 3.5 4.0 0.1 4.0 4.0 41 Bug Screen 0.76 1.3 1.3 10.0 0.1 10.0 10.0 42 Bu Screen 0.76 1.3 1.3 10.0 0.1 10.0 10.0 43 Bu Screen 0.76 1.3 1.3 10.0 0.1 10.0 10.0 44 Bu Screen 0.76 2.3 25.5 4.0 0.1 4.0 4.0 45 Bu Screen 0.76 9.0 20.0 16.0 0.1 16.0 16.0 46 Bu Screen 0.76 1.3 1.3 10.0 0.1 10.0 10.0 47 Bu Screen 0.76 1.3 1.3 10.0 0.1 10.0 10.0 48 Bug Screen 1 0.761 1.3 1.31 10.01 0.1 10-01 10.0 EnemyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Pae 10 of 29 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lunan Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix T e Area Factor Cavitv Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 49 Window 31.5 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 50 Window 72.0 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 51 Window 24.0 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 52 Window 76.0 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 53 Window 60.8 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 54 Window 4.2 0.720 NFRC 0.59 NFRC 315 New Glass Block Main Residence 55 Window 2.3 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 56 Window 2.3 0.450 NFRC 0.22 NFRC 315 New Heritage Windows Main Residence 57 Window 48.0 0.450 NFRC 0.22 NFRC 45 New Heritage Windows Studio 58 Window 4.0 0.450 NFRC 1 0.22 NFRC 135 New Heritage Windows Studio 59 Window 10.0 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Studio 60 Window 4.0 0.450 NFRC 0.22 NFRC 135 New Heritage Windows Studio (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq -Hc--F- it Wd Len Hot I LExt RExt Dist Left Fin Ri ht Fin Len I Hot Dist Len H t 49 Bug Screen 0.76 9.0 3.5 4.0 0.11 4.0 4.0 50 Bug Screen 0.76 9.0 8.0 4.0 0.11 4.0 4.0 51 Bug Screen 0.76 8.0 3.0 4.0 0.1 4.0 4.0 52 Bug Screen 0.76 8.0 9.5 8.0 0.1 8.0 8.0 53 Bug Screen 0.76 7.6 8.0 4.0 0.1 4.01 4.0 54 Bug Screen 0.76 6.0 0.7 6.0 0.1 6.01 6.0 55 Bug Screen 0.76 1.51 1.5 10-01 0.1 10-01 10.0 56 Bug Screen 0.76 1.51 1.5 10.0 0.1 10-01 10.0 57 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 EnerqyPro 5.1 by EnemySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Pae 11 of 29 • 0 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lunan Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1/4/2012 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC Residence 4,238 49,161 AC -4 Studio 410 3,854 Totals 4,6481 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 Central Furnace 80% AFUE Split Air Conditioner 13.2 SEER Setback New AC -4 1 Split Heat Pum 9.00 HSPF Split Heat Pump 25.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New AC -4 Ductless/with Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS S stem Name Oty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Rinnai Tankless 2 Instant Gas All Pipes Ins 195,000 1 0.85 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 i� a System Name Pipe Len th Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 12 of 29 • • MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Lunan Residence Date 1/4/2012 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 4150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)113: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of 113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatina sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(6)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150(0)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 13 of 29 • • • MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Lunan Residence 1/4/2012 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such to a is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 14 of 29 0 • MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Lunan Residence 1/4/2012 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 /D: Page 15 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lunan Residence Date 1/4/2012 System Name HVAC Floor Area 4,238 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 4,864 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output erSystem 71,000 52,884 3,446 2,304 69,758 Total Output Btuh 71,000 0 Output Btuh/s ft 16.8 3,053 3,428 Cooling System 0 0 Output per System 47,000 0 0 0 0 Total Output Btuh 47,000 0 3,053 58,9907 3,446 0 Total Output ons 3.9 3,428 Total Output Btuh/s ft 11.1 Total Output s f rron 1,082.0 76,615 Air System CFM perSystem 1,500 HVAC EOUIPMENT SELECTION Airflow cfm 1,500 New HVAC Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 29,147 29,147 16,216 71,000 16,216 71,000 Aug 3 PM I Jan 1 AM Airflow cfm/s ft 0.35 Airflow cfm/Ton 383.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF _ 68 OF Outside Air 0 cfm Supply Fan 1,500 cfm 68 OF 68 OF IMEM 100 OF Heating Coil T' W 98 OF _._.._....._ ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/70°F 79/70°F 66/66°F c Outside AirAr 0 cfm Supply Fan Cooling Coil68 1,500 cfm 79 / 70 OF / 66 OF .................................................. 66.0% ROOM In 781 70 OF EnergyPro5.1 by EnergySoft User Number: 6712 RunCode: 2012-01-04711:30:56 ID: Page 16 of 29 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Lunan Residence 1/4/2012 System Name Floor Area AC -4 410 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Total Room Loads 257 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 5,476 0 0 0 0 0 0 5,476 Latent CFM 302 234 0 0 302 Sensible Output per System 14,000 9,197 Total Output Btuh 14,000 Output Btuh/ ft 34.1 0 Cooling System 0 Output per System 12,000 0 Total Output Btuh 12,000 0 Total Output ons 1.0 0 Total Output Btuh/s ft 29.3 Total output s ft/Ton 410.0 9,197 Air System CFM per System 350 HVAC EQUIPMENT SELECTION Airflow cfm 350 1 Ton Fujitsu Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 9,130 9,130 988 8,744 988 8,744 Aug 3 PM Jan 1 AM Airflow cfm/s ft 0.85 Airflow cfm/Ton 350.0 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan 350 cfm 68 OF 68 OF 105 OF Heating Coil 105 of R0707MJN 68 OF (_nnI IN(: CVSTFM PSVCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112/78°F ----1 Outside Air 0 cfm 75162 OF 75 / 62 OF 55 / 54 OF o Supply Fan 55 / 54 OF 350 cfm Cooling Coil _._........ 47.2% ROOMNJ 75/62°F 75/62°F I EnerovPro 5.1 by EnemvSoff User Number: 6712 RunCode: 2012-01-04711:30:56 ID: 17 of 29 • 0 • ROOM LOAD SUMMARY Project Name Date Lunan Residence 1/4/2012 System Name Floor Area HVAC 4,238 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM TSensible Latent CFM I Sensible Latent CFM I Sensible Main Residence I Residence I 1 1 4,8641 5ZB641 3,446 4,8641 52,8841 3,446 2,3041 69,758 PAGE TOTAL TOTAL* 4,8641 52,8841 3,4461 2,3041 69,758 4,8641 52,8841 3,4461 2,3041 69,758 18 of 29 C] • C] ROOM LOAD SUMMARY Project Name Date Lunan Residence 1/4/2012 System Name Floor Area AC -4 410 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent. CFM Sensible Latent CFM Sensible Studio Studio 1 257 5,476 302 257 5,476 302 2341 9,197 PAGE TOTAL TOTAL' 257 5,476 302 234 9,197 257 5,476 302 234 9,197 C.� ROOM HEATING PEAK LOADS Project Name Date Lunan Residence 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Time of Peak Jan 1 AM Floor Area 4,238.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT °F Btu/hr R-38 Roof Attic 4,226.9 X 0.0260 X 44 = 4,836 So/atube Skylight 3.6 X 0.3000 X 44 = 48 Bristol Skylight 7.5 X 0.5400 X 44 = 178 R-21 Wall 3,255.5. X 0.0690 X 44 = 9,884 Heritage Windows 1,323.0 X 0.4500 X 44 = 26,195 Glass Block 8.4 X 0.7200 X 44 = 266 Wood Door 20.1 X 1.4500 X 44 = 1,282 Slab -On -Grade Perim = 521.0 X 0.7300 X 44 = 16,735 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 59,423 Infiltration:[ 1.00 X 1.064 X 4,238 X 11.60 X 0.269 /60] X 44 = 10,335 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 69,758 Energ Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2012-01-04T11:30:56 ID: Page 20 of 29 • ROOM HEATING PEAK LOADS Project Name Lunan Residence Date 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Studio Floor Area 410.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 410.0 X R-21 Wall 835.9 X Heritage Windows 66.0 X Wood Door 20.1 X Slab -On -Grade perim = 100.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 410 X Schedule Air Sensible Area Ceiling Fraction U -Value AT OF 0.0260 X 42 = 0.0690 X 42 = 0.4500 X 42 _ 1.4500 X 42 = 0.7300 X 42 = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = _ X = X = X = X = X X = X X = L X - another room Page Total 9.40 X 0.275 /60] X 42 Height ACH AT Btu/hr 448 2,422 1,247 1,224 3,066 8,408 = 790 TOTAL HOURLY HEAT LOSS FOR ROOM 9,197 Energ Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2012-01-04711:30:56 /D: Page 21 of 29 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lunan Residence 1 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 4,238.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall R-21 Wall Wood Door R-21 Wall R-21 Wall W] (SE) (SE) Area X X X X X X X X X U -Factor X X X X . X X X X X CLTD' = = = = = = = = = 4,226.9 0.0260 56.0 748.8 0.0690 29.0 1,057.1 0.0690 31.0 20.1 1.4500 31.0 594.01 0.0690 31.0 855.6 0.0690 30.2 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 22.7 2.5 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanactrn inn Skylight Skylight Skylight Skylight Skylight Skylight Skylight Skylight Skylight (►M (►M Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 17.5 0.6 58.1 0.0 22.7 2.5 64.6 0.0 22.7 2.5 64.6 0.0 22.7 2.5 64.61 Page Total Btu/hr 6,154 1,498 2,261 903 1,271 1.785 13,873 Btu/hr 35 35 35 35 35 35 162 162 162 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 231.90 X 34 = 7,266 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,8841 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM _ 3,4461 • i 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Lunan Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature Floor Area 4,238.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: Surfaces Orientation Date 1/4/2012 112 OF 78 OF 34 OF Area X X X X X X X X X U -Factor_ X X X X X X X X X CLTD' = = = = = = = GLF 4.0 0.0 X 17.2 + 4.6 X 24.2 = 0.0 X 17.2 + 19.0 X 24.2 = 0.0 X 17.2 + 18.0 X 24.2 J I= X 17.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Al AJ AK AL AM AQ AR Au D Orientation (NE) (NE) (NE) (NE) (NE) (NE) Area GLF Area. Occupants GLF 4.0 0.0 X 17.2 + 4.6 X 24.2 = 0.0 X 17.2 + 19.0 X 24.2 = 0.0 X 17.2 + 18.0 X 24.2 = 0.0 X 17.2 + 4.6 X 24.2 = 0.0 X 17.2 + 112.5 X 24.2 = 0.0 X 17.2 + 12.0 X 24.2 = 0.0 X 17.2 + 4.0 X 24.2 = 0.0 X 17.2 + 4.0 X 24.2 = 0.0 X 17.2 + 4.5 X 24.2 -- Page Page Total Btu/hr 01 Btu/hr 111 461 436 111 Z727 291 97 97 109 4, 441 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,6001 Btu = 1,600 Infiltration: 1.064 X 0.87 X 231.90 X 34 = 7,266 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,884 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible • CFM ELA AW • • 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lunan Residence 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 4,238.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = + 0.0 74.7 + + 0.0 54.0 0.0 58.9 + 0.0 74.7 + 0.0 4.5 + + 0.0 12.3 0.0 4.2 + 0.0 + 0.0 24.0 L= Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) FP_nPSfrafinn AX A 1 c 8 E M AT 20 (SE) • Shaded Area ` GLF X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 17.2 X 36.3 X 17.2 Unshaded Area X X X X X X X X X GLF 22.2 = 22.2 = 22.2 = 22.2 = 22.2 = 22.2 = 22.2 = 49.9 = 22.2 = Page Total 4.5 + 0.0 74.7 + + 0.0 54.0 0.0 58.9 + 0.0 74.7 + 0.0 4.5 + + 0.0 12.3 0.0 4.2 + 0.0 + 0.0 24.0 Btu/hr Btu/hr 77 1,282 927 1,011 1,282 77 211 152 412 5,432 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 231.90 X 34 = 7,266 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,884 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4.771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible CFM ELA AW • 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lunan Residence 1 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 4,238.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF, Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X X X - X X = X X = X X = X X = Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 31 25 24 AV AY 32 N AG N Orientation I (SW I Shaded Area 17.8 X 37.2 X 37.2 X 37.2 X 4.5 X 35.6 X 0.0 X 67.5 X 0,01 X GLF 17.2 17.2 17.2 17.2 17.2 17.2 17.2 17.2 17.2 Unshaded Area + 6.2 + 2.8 + 2.8 + 2.8 + 0.0 + 12.4 + 6.0 + 0.0 +1 6.0 X X X X X X X X X GLF = = = = = = = = = 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 24.2 Page Total Btu/hr 443 700 700 700 77 886 133 1,159 145 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. ` Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.87 X 231.90 X 34 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,884 Latent GainBtu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible CFM ELA AW GAIN FOR ROOM 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lunan Residence 11412.012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 °F Floor Area 4,238.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF, Opaque Surfaces Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 24.2 = = = = = = = = = 17.2 2.3 24.2 17.2 2.3 24.2 17.2 31.5 24.2 0.0 0.0 0.0 0.0 0.0 17.2 1.7 24.2 17.2 1.7 24.2 17.2 1.7 24.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature. Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF O P Q T W X Y Z 16 0.0 0.0 0.0 0.0 X X X X X X X X X 17.2 + + + + + + + + + 2.3 X X X X X X X X X 24.2 = = = = = = = = = 17.2 2.3 24.2 17.2 2.3 24.2 17.2 31.5 24.2 0.0 0.0 0.0 0.0 0.0 17.2 1.7 24.2 17.2 1.7 24.2 17.2 1.7 24.2 17.2 58.7 24.2 17.2 180.0 24.2 Page Total Internal Gain Occupants 4.0 Occupants X 230 Btuh/occ. _ Equipment 1.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.87 X 231.90 X 34 = Air Sensible CFM ELA AT Btu/hr �I 01 56 56 56 764 41 41 41 1,423 4,363 6,8 Btu/hr 1 1 7,2661 I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,8841 Latent Gain , Occupants 4.0 Occupants X 200 ,Btuh/occ. _ Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = Air Sensible CFM ELA AW Btu/hr Z6461 • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,4461 • n 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lunan Residence. 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 4,238.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Surfaces Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = GLF = = = = = = = = = 0.0 17.2 1.7 24.2 0.0 17.2 1.7 24.2 0.0 17.2 1.7 24.2 0.0 17.2 31.5 24.2 0.0 17.2 72.0 24.2 0.0 17.2 24.0 24.2 0.0 17.2 76.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fanactratinn AA AB AC AF AH 17 26 AP AS Orientatinn (NM (NVt9 (NW) (NM (NW) (NM (NWJ (N W) (NW) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.2 1.7 24.2 0.0 17.2 1.7 24.2 0.0 17.2 1.7 24.2 0.0 17.2 31.5 24.2 0.0 17.2 72.0 24.2 0.0 17.2 24.0 24.2 0.0 17.2 76.0 24.2 0.0 17.2 60.8 24.2 0.0 36.3 4.2 55.3 Page Total Btu/hr Btu/hr 41 41 41 764 1,745 582 1,842 1.474 1 2321 6, Occupants 4.0 Occupants X 230 Btuh/occ. = E920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 231.90 X 34 = 7,266 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,8841 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 1 Btuh/occ. _ 800 Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible CFM ELA AW ROOM • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lunan Residence 1 1/4/2012 ROOM INFORMATION DESIGN CONDITIONS Room Name Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 4,238.0 R2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature— 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X X X = X X = X X = X J X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr AN (NM 0.0 X 17.2 + 2.3 X 24.2 = 56 AO (NI" 0.0 X 17.2 + 2.3 X 24.2 = 56 X + X - X + X = X + X = X + X - X, + X - X + X = X +1 X = Page Total 111 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 820 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 231.90 X 34 = 7,266 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,884 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 231.90 X 0.00276 = 2,646 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM .3 446 Ene Pro 5.1 by EneravSoft User Number.- 6712 RunCode: 2012-01-04711:30:56 ID:. Pa a 28 of 29 0 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lunan Residence 11412012 ROOM INFORMATION DESIGN CONDITIONS Room Name Studio Outdoor Dry Bulb Temperature 112 OF Floor Area 410.0ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF, Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Attic (N) 410.0 X 0.0260 X 56.0 = 597 R-21 Wall (NE) 214.0 X 0.0690 X 29.0 = 428 R-21 Wall (SE) 186.0 X 0.0690 X 31.0 = 398 R-21 Wall (SIM 232.9 X 0.0690 X 31.0 = 498 Wood Door (SlM 20.1 X 1.4500 X 31.0 = 903 R-21 Wall (NW) 203.0 X 0.0690 X 30.2 = 423 X X = X X = X X - Page Total 3,248 Items shown with an asterisk (•) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6 (NE) 0.0 X 17.2 + 48.0 X 24.2 = 1,163 G (SE) 0.0 X 17.2 + 4.0 X 22.2 = 89 H (SE) 0.0 X 17.2 + 10.0 X 22.2 = 222 1 (SE) 0.0 X 17.2 + 4.0 X 22.2 = 89 X + X = X + X - X + X = X + X = X +1 X = Page Total 1,564 Internal Gain Btu/hr Occupants 0.0 Occupants X 230 Btuh/occ. = 0 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.89 X 18.89 X 37 = 664 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,476 Latent Gain Btu/hr Occu ants 0.0 Occupants X 200 Btuh/occ. = 0 Infiltration: 4,771 X 0.89 X 18.89 X 0.00376 = 302 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 302 EnerovPro 5.1 bv EnerqvSoft User Number. 6712 RunCode: 2012-01-04711:30:56 ID: Page 29 of 29