0312-041 (AR)LICENSED CONTRACTOR DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force•and effect. ,-! J� ;
License # Lic. Class Exp. Date
104183 A , �,I13►�2c
Date ' �� Signature of Contractor �*r , }�� Y'
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date Signature of Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
( ) I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier STA1 E 1d)y1n Policy No. 1.542568-201)*
.3
section need not be completed if the permit valuation is for $100.00 or less).
() I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agreeithat,'if I should become
subject to the workers' compensation provisions of Section 3700$1of the Labor
Code, I shall forthwith comply with those provisions
Date: f - / ^ t Applicant s <r - / 4; C %
Warning: Failure to secure Workers' Compensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permit subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize rep resentativesrof'this City to enter upon
the above-mentioned propertyafor inspectionpurpo'seS. /F
Signature (Owner/Agent),Y. 'L r- � ��j �[I Date j
BUILDING PERMIT PERMIT#
ff�'i2-fkdi
DATE 0i/0SX VALUATION S2.00001 LOT 35 TRACT 2,0717YU18
JOB SITE
ADDRESS ;552 80 I3: �)7� BEACH
APN _ ^
OWNER
CONTRACTOR / DESIGNER / ENGINEER N IINEER
yy- �yOrrFAM
CBR E1;i , XiC0, ?•7ryR
,
55•ef3Cf s'E :323? r' 7sAi;H
54015 "501 )115:�,F:NFILL1Z
IA QUMP1'A C:A. 92:53
1A QUWA CA 92253
(160)771-1877 CLIL4 5620
USE OF PERMIT
RI?.S.€U)7rI>1V_AL ADD I7. O.H
REVISION TO 103 EVATRIUM irk CJ DSURE PP"5 101JSLY
i•'Es'WI`ITTED(0309-121),2001 C130.
'VALUATION 4000.00 L3
PW CHECK FEF 101.0110.439.318 $29,25
CONSTRUCTION FEE 101.OW-41$-000 !45.00
S1 RO140 MOTION FEE - ItESID 101.000.241-000
Q
D
07 2004
C1 r.,
C.- Lt.
r1-�rro "E r
SUD-TtXALCOI+%'I!'RIMMON AND PLAN
I.= PRE -PAM 179L. S
$0100
T(Y.CAL PKT?M 'FFCYS DUE nOW
S74.7 5
RECEIPT
DATE
%' L 0
BY. "
r
1 NALE
L(. D
It PECTOR
vv''
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE •
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
POOLS - SPAS
steel
Set Backs
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground P1bg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection
Encapsulation
Gas Piping
Gas Test
Appliances
Final
Final
Utility Notice (Gas)
ELECTRICAL APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
--
Total Permit Fees
L
ew
r
Bit1 #
\
'.
Permit # K 0$
' O /
�3
City of La Quinta
Building 8t Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address-�J'� D
Owttcr's Name:
A. P. Number:
Address:
X
x
Legal Description:
Contractor.C- M
Address:
City. ST. Zip: CJS✓`
r ,., •• _ ,
]<Telephone:
XProject Description:
J�
X
City, ST. Zip:
Telephone:
1/VV)
uS�b� O �tx�s'i-ttn
A
State Lic. # : �
City Lic. #:
Arch., Engr., Designer.
Address:
StA 0,J9
City. ST. Zip:
X
X
Telephone..
State Lic. #:
Name of Contact Person:C2
Telephone # of Contact Person: (
Construction Type= y _ Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
S Sq. Ft.: #Stories: #Units:
stimated Value of Proiect:
APPLICANT: DO NOT WRITE BELOW THIS LINE
q
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
Amount
Plan Secs
A
Plan Check submitted
l'
Item
Plan Check Deposit
Structural Cales.
Reviewed, ready for corrections
Plan Check Balance
Truss Cales.
Catled Contact Person
Energy Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correctionstissue
Electrical
Subcontactor List
Called Contact Person '
Plumbing
Grant Deed
Plans picked up
s.nl.l.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for correcti srssue
/ b
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
6
School Fees
Total Permit Fees
A kej 9) %M= 0 eo Y, c�so- C. (
o
e
TITLE 24
Energy Conservation
Standards Compliance Report,
t .
ROBERDES RES. ALTERATION
54-015 SOUTHERN HILLS
PGA WEST - LA QUINTA
December 3, 2003 Job•'Number: 23990A
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED eneral Contractor:
FOR CONST UCTION CBR, INC.
DA ROBERDES
DAAIOI_0855 `W SHINGTON STREET
INI A, CA 92253.
760-771-2278 . .
Madlin S. �
enterprises
®®®®v®
Catherine M. Madlin, Certified Energy Analyst.
Post Office Box 1443 ® Palm Springs, CA 92263
760-322-5004 / 323-3644, (fax) -
E-mail: GMadlin@aol.com
5s-aao P�
bbd $ems- a?v 156"
CERTIFICATE OF COMPLIANCE: RESIDENTIAL
Page 1 ' CF -1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
. PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262•
760-322-5004 Field Checkl Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-----------------------------
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP6207 User-Madlin's Enterprises Run -ALTERED SPACE
----------------------------------------=--------------------------------------
j
GENERAL INFORMATION
'
-------------------
Conditioned Floor Area...... 1098 sf
j
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Alteration'
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Stories.......... 1 '
(
Floor Construction Type...." Slab On Grade
j
Glazing Percentage......... 7.6 8 of floor area
Average Glazing U -factor... 0.72 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
Component
-------------------------
Frame Cavity Sheathing Total Assembly
Type
Type R -value R -value R -value U -factor Location/Comments
---------=--
• Wall
------------------------------------- ------------------------
Wood R-21 R-0 R-21 0.059 EXISTING WALLS
i Wall
Wood R-17.8 R-0 R-17.8 . 0.065 NEW WALL
WALL FILL-IN
Wall
Wood R-14 R-0 R-14 0.096 SPECIAL WALL
Roof
Wood R-11 R-19 R-30 0.031'
S1abEdge
None R-0 R-0 F2=0.760
S1abEdge
None R-0 R-0 F2=0.510
j
FENESTRATION
j
Over -
Area U- Interior Exterior
hang/
Orientation (sf) Factor SHGC Shading Shading
Fins
--------------------
Door
----- ------ -----------------------------------
Left (N) 35.0 0.850 0.700 Standard Standard
-----
None
s Window
Left (N) 15.0 0.720 0.730 Standard Standard
None
Window
Left (N) 33.0 0.570 0.670 Standard Standard
None
i
"
SLAB SURFACES
-------------Area
Slab Type (sf)
---------------- ------
Standard Slab 1098
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
--------------- ------------- ________
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
---------------------------------------------7---------------------------------
HVAC SYSTEMS
------------
Refrigerant Tested ACCA
Equipment Minimum Charge and Duct Duct Duct Manual Thermostat
Type Efficiency Airflow Location R -value Leakage D Type
------------ -------------------------------------------- ------ ----------
Furnace 0.800 AFUE n/a Attic R-6 No No Setback
ACSplit 12.25 SEER No Attic R-6 No No Setback
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
REMARKS
The values and materials used in this existing house calculation
are based on Title 24 compliance calculations by Madlin's
Enterprises dated 6/1995.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determing the HVAC design loads and
equipment selection(s). The HVAC design shall be done in accord-
ance with industry standards. The load calculation in this
report considers ambient temperature load, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The installing glazing contractor shall provide the required
CF -6R Installation Certificate with installed glazing values
and areas.
The HVAC equipment is existing.
The night setback thermostat is existing.
The water heaters are existing.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
MICR0PAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
--------------------
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name....
DAVID ROBERDES
Name....
CATHERINE M. MADLIN
Company.
CBR, INC.
Company.
Madlin's Enterprises
Address.
50855 WASHINGTON #C201
Address.
P.O. Box 1443
PGA WEST LA QUINT
LA QUINTA, CA 92253
Palm Springs, CA 92262
Phone...
760-771-2278
Phone...
760-3 2-5004
License.
d
Signed..
Signed..
Plan -Check
Mate)
(date)
ENFORCEMENT AGENCY
Name.... Certified Energy analyst.
Title... Catherine M. Madlin
Agency.. NR 98-90.544
r r R 98-90.144
Phone... rr
Signed.. C A D E C
(date) Cdifanfo an of ONlding Eneigy ConwUorn
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
Page 1
___________________________
MF -1R
Project Title..........
ROBERDES.ALTERATION
Date..12/03/03
10:29:43
Project Address........
55-780 PEBBLE BEACH
******* ---------------------
PGA WEST LA QUINT
*v6.01*
Documentation Author...
CATHERINE M. MADLIN
*******
Building Permit
Madlin's Enterprises
P.O. Box 1443
Plan -Check
Date
Palm Springs, CA 92262
760-322-5004
Field C ec
Date
Climate Zone...........
15
---------------------
Compliance Method......
MICROPAS6 v6.01 for 2001
Standards by Enercomp,
Inc.
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
----------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used.' Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er ment
*150,(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
to exterior mass walls).
*150(d): Minimum R-13 raised floor insulation in framed floors.
150(1): Slab edge insulation - water absorption rate no greater
than 0.38, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
C. Flue damper and control
2. No continuous burning gas pilots allowed.
NA
NA
NA
r
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2MF-1R
--------------
___________________________________________________________________________
Project Title.......... ROBERDES.ALTERATION............. Date..12/03/03 10:29:43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and New
faucets certified by the Commission. oni�
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
150(i): Setback thermostat on all applicable heating and/or
cooling systems. _Xr&
150'(j): Pipe and Tank insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
i having an installed thermal resistance of R-12 or greater.
i2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated(R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
i other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
f 6. Piping insulated between heating source and indirect
hot water tank. EKTC,
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sectons
601, 603, and 604, and standard 6-3; ducts insulated to a .
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used. Building cavities shall not be used for
conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber
addhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually New
operated dampers. a vc
114: Pool and Spa Heating Systems and Equipment
I 1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating.
j b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heateFs, spa heaters or
household cooking appliances have no continuously burning
MANDATORY MEASURES CHECKLIST: RESIDENTIAL
-----------------Page -3----------MF_1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
----------------------------------
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF_ 1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
j pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr). eM.,
LIGHTING MEASURES
-----------------
150(k)l: Luminaires for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be controlled by a switch on a readily accessible
lighting control panel at an entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at
least one luminaire with lamps with an efficacy of 40
lumens/watt or greater switched at the entrance to the
room or one of the alternatives to this requirement
allowed in Sec. 150(k)2.; and recessed ceiling fixtures
are IC (insulation cover) approved.
Design- Enforce-
er ment
,JIA
Ma in s
enterptises
Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) .......
Title 24 Energy Conservation Standards
Compliance Report
r
This proposed project has been reviewed for compliance with the 2001 State of California
Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design
described in this compliance portfolio is in conformance with the standards as outlined in
the attached compliance forms and documentation.
Date: December 3, 2003
Job Number: 23990A
General Contractor: CBR, INC. / DAVID ROBERDES
Owner's Name: CHANG ROBERDES
Project Name: ,ROBERDES RESIDENTIAL ALTERATION
Project Location: 54-015 SOUTHERN HILLS - PGA WEST - LA QUINTA
Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM
Orientation Of Entry: WEST - SEE SITE PLAN
Certified Energy Analyst
Catherine M. Madlin
NR 98-90-544
r r R 98-90-144
rr
C A 8 E C
California Association of Building Energy Consultants
v. Post Office Box 1443 v Palm Springs, Ca 92263 v
v Post Office Box 1443 v Palm Springs, Ca 92263 v
MaIn s.
enterpnses
Catherine M. Madfin, Certified Energy Analyst v 760-322-5004
L 323-3644 (fax)
vvvvvvv
..................... .............. ...... .............. . .... .... ....................
D DRIP TI INC20.. .. ................................
-X
.... b.. ON: ........................... ......................... .. .. ..........
Job Name
ROBERDES RESIDENTIAL ALTERATION
Job No. / File No.
23990A
Method of Compliance
Micropas V6.1 Computer Simulation
Existing -Plus -Alteration Calculation Method
Insulation: Roof Ceiling
Existing
Insulation: Walls
Exterior Wall Fill-ins: R-19
Special Thin Wall: R-14 - Polyurethane
Insulation: Floor - Slab on Grade
Not Required
Insulation: H.V.A.C. Ducts/Location/Testing
Existing Ducts
Glazing U Value / Type: French Door
0.85,'Dual Pane, Aluminum Frame
(CEC Default Value)
Glazing U -Value / Type: Fixed
0.72, Dual Pane, Low E2, Aluminum Frame
(CEC Default Value)
Glazing U -Value / Type: Glass Block
0.57 (CEC Default Value)
Glazing- Solar Heat Gain Coefficient (Uncoated)
0.70 Fr.Dr. / 0.73 Fixed Glass Block Clear
Glazing: Exterior Shading
Not Required
Thermal Mass Square Footage & %
Not Required
H.V.A.C. System Type
Existing Equipment
Domestic Hot Water Heater
Existing Equipment
Other Requirements
Applicable Mandatory Measures
v Post Office Box 1443 v Palm Springs, Ca 92263 v
i
Madlin s
- enterprises
Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 &x)
Title 24 Compliance Forms
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
----- --------------------------------------------------
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262
760-322-5004 Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method ....... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------
-----------------------------
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
------------------------------------------------------=------------------------
GENERAL INFORMATION
Conditioned Floor Area..... 1098 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Alteration
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Stories.......... 1
Floor Construction Type.... Slab On Grade
Glazing Percentage......... 7.6 % of floor area
Average Glazing U -factor... 0.72 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
Average Ceiling Height..... 10 ft
BUILDING SHELL INSULATION
Component
Frame
Cavity
Sheathing Total Assembly
Type
------------
Type
-------
R -value
R -value. R -value U -factor Location/Comments
Wall
Wood
--------
R-21
----------------------
R-0 R-21 0.059
- --------------------
EXISTING WALLS
Wall
Wood
R-17.8
R-0 R-17.8 0.065
NEW WALL
WALL FILL-IN
Wall
Wood
R-14
R-0 R-14 0.096
SPECIAL WALL
Roof
Wood
R-11
R-19 R-30 0.031
S1abEdge
None
R-0
R-0 F2=0.760
S1abEdge
i
None
R-0
R-0 F2=0.510
j
FENESTRATION
j
Over -
Area
U- Interior
Exterior
hang/
Orientation
I
(sf)
Factor SHGC Shading
Shading
Fins
Door
Left (N)
35.0
0.850 0.700 Standard
Standard
None
Window,
Left (N)
15.0
0.720 0.730 Standard
Standard
None
Window
Left (N)
33.0
0.570 0.670 Standard
Standard
None
i
SLAB SURFACES
-------------
Area
Slab Type (sf)
i
i
Standard Slab 1098
.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
HVAC SYSTEMS
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer. -and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
REMARKS
The values and materials used in this existing house calculation
are based on Title 24 compliance calculations by Madlin's
Enterprises dated 6/1995.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determing the HVAC design loads and
equipment selection(s). The HVAC design shall be done in accord-
ance with industry standards. The load calculation in this
report considers ambient temperature load, solar gain,
people and a fixed latent heat gain percentage.. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The installing glazing contractor shall provide the required
CF -6R Installation Certificate with installed glazing values
and areas. -
The HVAC equipment is existing.
The night setback thermostat is existing.
The water heaters are existing.
Refrigerant
Tested
ACCA
Equipment
Minimum
Charge and Duct
Duct
Duct
Manual
Thermostat
Type
------------
Efficiency
------------
Airflow Location
------------------
R -value
Leakage
D
Type
Furnace
0.800 AFUE
n/a Attic
-------
R-6
-------
No
------
No
----------
Setback
ACSplit
12.25 SEER
No Attic
R-6
No
No
Setback
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer. -and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
REMARKS
The values and materials used in this existing house calculation
are based on Title 24 compliance calculations by Madlin's
Enterprises dated 6/1995.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determing the HVAC design loads and
equipment selection(s). The HVAC design shall be done in accord-
ance with industry standards. The load calculation in this
report considers ambient temperature load, solar gain,
people and a fixed latent heat gain percentage.. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The installing glazing contractor shall provide the required
CF -6R Installation Certificate with installed glazing values
and areas. -
The HVAC equipment is existing.
The night setback thermostat is existing.
The water heaters are existing.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with'Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations. to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
Name.... DAVID ROBERDES
Company. CBR, INC.
Address. 50855 WASHINGTON #C201
LA QUINTA, CA 92253
Phone... 760-771-2278
License.
Signed..
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... CATHERINE M. MADLIN
Company. Madlin's Enterprises
Address. P.O. Box 1443
Palm Springs, CA 92262
Phone... 760-322-5004
Signed..
(date F
Certified Energy Analyst
Catherine M. Madlin
NR 98.90-W
r r R 9&90-144
rr
�CABEC
California Association of Building Energy Conaftm
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan C ec Date
Palm Springs, CA 92262
760-322-5004 Field Che --c Date
Climate Zone ........ •... 15
---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
__________________________
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R
! I User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-----------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
` *150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
to exterior mass walls).
Design- Enforce-
erment
I/
N/A
*150(a): Minimum 'R-13 raised floor insulation in framed floors.
150(1): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
.150(8): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
A1/4
/yA
NA
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce -
110 -113: HVAC equipment, water heaters, showerheads and
r
faucets certified by the Commission.
dAh-
.150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
✓
150(i): Setback thermostat on all applicable heating and/or
cooling systems.
E�T�
150(j): Pipe and Tank -insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
' insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
6. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sectons
601, 603, and 604, and standard 6-3; ducts insulated to a
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either
mesh
or tape shall be used. Building cavities shall not be used.for
conveying conditioned air. Joints and seams of duct systems
and
their components shall not be sealed with cloth back rubber
' addhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2.. Exhaust fan.systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
i either automatic or readily accessible, manually
NSW
operated dampers.
OWL
i 114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for .future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29.43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr). C'x7Z�
LIGHTING MEASURES
-----------------
150(k)l: Luminaires for general lighting in kitchens shall
have lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general lighting
shall be'controlled by a switch on a readily accessible
lighting control panel at an entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at
least one luminaire with lamps with an efficacy of 40
lumens/watt or greater switched at the entrance to the
room or one of the alternatives to this requirement
allowed in Sec. 150(k)2.; and -recessed ceiling fixtures
are IC (insulation cover) approved.
Design- Enforce-
er ment
/,l A
Remodeled Building
ADDITION WORKSHEET Page 1 ADD
-------------------------------------------------------
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:30:19
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262
760-322-5004 Field Check/ Date
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 by Enercomp, Inc.
------- ____________________________________________
MICROPAS6 v6.01 File-23990EXT Program -ADDITIONS
User#-MP0207. User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE
------------- ;
File Name. ..... ........ 23990EXT - EXISTING SPACE
Conditioned Floor Area..... 1098 sf
Standard Design Energy Use. 36.57 kBtu/sf-yr
Proposed Design Energy Use. 33.21 kBtu/sf-yr
NEW (EXISTING PLUS ADDITION/ALTERATION)
File Name. .............. 23990ALT - ALTERED SPACE
Conditioned Floor Area..... 1098 sf
Standard Design Energy Use. 36.97 kBtu/sf-yr
Proposed Design Energy Use. 34.11 kBtu/sf-yr.
FLOOR AREA RATIO
Floor
Existing
New
Area
Floor Area
Floor Area
Ratio
----------
1098
-------------
/ 1098
-------
= 1.000
DESIGN ENERGY
USE FOR NEW
(EXISTING PLUS
ADDITION/ALTERATION)
Floor
Addition/
New
Area
Existing
Existing
Alteration
Standard
-------------
Ratio
-------
Proposed
--------
Standard
Design
36.97
+ 1.000
x ( 0.00 -
--------
0.00)
--------
36.97
Note: If (Existing Proposed - Existing Standard) is
negative, this difference is set to zero.
------------------------------------------------
= ADDITION/ALTERATION ENERGY USE SUMMARY =
------------------- -
Addition/
Energy Use Alteration Proposed Compliance =
_ (kBtu/sf-yr) Design Design Margin =
------------------------------------------------------ _
New .................... 36.97 34.11 2.86 =
*** Addition/Alteration complies with Computer Performance *** _
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan C ec Date
Palm Springs, CA' 92262
760-322-5004 Field Check/ Date
Climate Zone........... 15 ---------------------
C ompliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
i I MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
Design
Design
Margin =
= Space Heating..........
1.62
1.97
-0.35 =
= Space Cooling.......... 35.35
32.14
3.21 -
1.ZONE
------
Total 36.97
--------
34.11
--------
.2.86
_ ***
water Heating not calculated
1.00 Yes Setback
2.0
GENERAL INFORMATION
Conditioned Floor Area...,. 1098 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Alteration
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... FullYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 1
Conditioned Volume......... 10980 cf
Slab -On -Grade Area......... 1098 sf
Glazing Percentage......... 7.6 % of floor area
Average Glazing U -factor... 0.72 Btu/hr-sf-F
Average Glazing SHGC....... 0.69
Average Ceiling Height..... 10 ft
BUILDING ZONE INFORMATION
Floor
# of.
Vent
Vent
Air
Area Volume
Dwell Cond- Thermostat
Height
Area
Leakage
Zone Type (sf) (cf)
-------------- ------------
Units itioned Type
(ft)
(sf)
Credit
1.ZONE
-----------------------
-----
--------
---------
Residence 1098 10980
1.00 Yes Setback
2.0
Standard
No
COMPUTER METHOD
SUMMARY
U- -
Act
Exterior Shade
Page 2 C -2R
Project Title..........
ROBERDES.ALTERATION
factor SHGC
-----
Date..12/03/03 10.29.43
Tilt
MICROPAS6
v6.01
File-23990ALT
Wth-CTZ15S92
Program -FORM C -2R
-------------------------------------------------------------------------------
User#-MP0207
User-Madlin's
--------------
Enterprises
35.0
Run -ALTERED SPACE
0
90
Standard/0.76
Standard/0.68
OPAQUE
SURFACES
0.720 0.730
0
90
Area
U-
---------------
Insul
Act
0.570 0.670
Solar
Form 3 Location/
Surface
-------------- ------
(sf)
factor
R-val
Azm
Tilt
Gains
Reference Comments
1.ZONE
-----
-----
---
----
-----
------------ ----------------
1
Wall
13
0.059
21
270
90
Yes
W.21.2X6.16 EXISTING WALLS
2
Wall
321
0.059
21
0
90
Yes
W.21.2X6.16
3
Wall
13
0.059
21
90
90
Yes
W.21.2X6.16
4
Wall
100
0.059
21
270
90
No
W.21.2X6.16
5
Wall
6
0.065
17.8
270
90
Yes
W.19.2X6.16 NEW WALL
j 6
Wall
32
0.065
17.8
0
90
Yes
W.19.2X6.16 WALL FILL-IN
i 7
Wall
10
0.065
17.8
'90
90
Yes
W.19.2X6.16• NEW WALL
8
Wall
88
0.096
14
0
90
Yes
W.13.2.5.FLT SPECIAL WALL
9
Roof
1098
0.031
30
n/a
0
Yes
R.30.2X4.24
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1.ZONE
10 S1abEdge 52 0.760 R-0 No
11 S1abEdge 10 0.510 R-0 No
FENESTRATION SURFACES
System
Type
-------------
1.ZONE
Furnace
ACSplit
HVAC SYSTEMS
------------
Refrigerant Tested ACCA
Minimum Charge and Duct Duct Duct Manual Duct
Efficiency Airflow Location R -value Leakage D Eff
---------------------------------------- ----
0.800 AFUE n/a Attic R-6 No No 0.770
12.25 SEER No Attic R-6 No No 0.626
Area
U- -
Act
Exterior Shade
Interior Shade
Orientation
----------------------
(sf)
-----
factor SHGC
-----
Azm
Tilt
Type/SHGC
Type/SHGC
1.ZONE
-----
---
----
--------------
--------------
1 Door Left (N)
35.0
0.850 0.700
0
90
Standard/0.76
Standard/0.68
2 Window Left (N)
15.0
0.720 0.730
0
90
Standard/0.76
Standard/0.68
3 Window Left (N)
33.0
0.570 0.670
0
90
Standard/0.76
Standard/0.68
SLAB SURFACES
-------------
Area
Slab Type
----------------
(sf)
1.ZONE
------
Standard
Slab
1098
System
Type
-------------
1.ZONE
Furnace
ACSplit
HVAC SYSTEMS
------------
Refrigerant Tested ACCA
Minimum Charge and Duct Duct Duct Manual Duct
Efficiency Airflow Location R -value Leakage D Eff
---------------------------------------- ----
0.800 AFUE n/a Attic R-6 No No 0.770
12.25 SEER No Attic R-6 No No 0.626
COMPUTER METHOD SUMMARY Page 3 C -2R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE.
-------------------------------------------------------------------------------
s SPECIAL FEATURES AND.MODELING ASSUMPTIONS
-------------------------- ---------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
REMARKS
The values and materials used in this existing house calculation
are based on Title 24 compliance calculations by Madlin's
Enterprises dated 6/1995.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
i is responsible for determing the HVAC design loads and
j equipment selection(s). The HVAC design shall be done in accord-
ance with industry standards. The load calculation in this
report considers ambient temperature load, solar gain,
people and a fixed latent heat gain percentage. This basic
load must be adjusted for additional design conditions and
system/equipment performance.
The installing glazing contractor shall provide the required
CF -6R Installation Certificate with installed glazing values
and areas.
The HVAC equipment is existing.
The night setback thermostat is existing.
The water heaters•are existing.
CONSTRUCTION ASSEMBLY Page 1 3R.
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
_____________________________________________________
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------=-----------------------------
Parallel Path Method
Reference Name . W.21.2X6.16
Description .... Wall R-21 2x6 16oc
Type ........... Wall
R -Value 21 Hr=sf-F/Btu
Framing
Material ..... FIR.2X6
Type - .... Wood
Description .. 2x6 fir
Spacing ...... 16 inches on center
Framing Frac.. 0.15
---------------------------------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
i-------------
Name
Description
----------------------------------------
R -Value R
-Value
0.
FILM.EX
Exterior air film: winter value
------------------
0.17
0.17
1.
STUCCO.0.88
0.875 in stucco
0.17
0.17,
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
BATT.R21
R-21 batt insul (.cavity = 5.5 in)
21.00
--
3f..
FIR.2X6
2x6 fir
--
5.45
4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
--------- ---------
Total Unadjusted R -Values 22.54
6.98
FRAMING ADJUSTMENT
CALCULATION
i
Cavity Framing
Total
U -Factor: (1 / 22.54 x 0.85) + (1 / 6.98 x 0.15) =
0.059 Btu/hr-sf-F
Total
i
i
R -Value:
1'/ 0.059 =
16.89 hr-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 2 3R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
MICROPAS6 v6.01 File-2399.0ALT Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
-------------------------------------------------------------------------------
--------------- Parallel Path Method
Reference Name . W.19.2X6.16
Description .... Wall R-19 2x6 16oc
Type Wall
R -Value ........ 17.8 Hr-sf-F/Btu
Framing
Material ..... FIR.2X6
Type ..... Wood
Description .. 2x6 fir
Spacing .... 16 inches on center
Framing Frac.. 0.15
-----------------------.----------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
-------------------------------------------------
U-Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-.F
Total R -Value: 1 / 0.065 = 15.28 hr-sf-F/Btu
Material
Cavity
Frame
Name
-------------
Description
----------------------------------------
R -Value
R-Value
0.
FILM.EX
Exterior air film: winter value
---------
0.17
---------
0.17
1.
STUCCO.0.88
0.875 in stucco
0.17
0.17
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
BATT.R19
R-19 batt insul (cavity = 5.5 in)
17.80
--
3f.
FIR.2X6
2x6 fir
--
5.45
4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values
---------
19.34
---------
6.98
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
-------------------------------------------------
U-Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-.F
Total R -Value: 1 / 0.065 = 15.28 hr-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 3 3R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29:43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
------------------------------------------------------------------------------
---- Parallel Path Method
Reference Name . W.13.2.5.FLT
Description Wall R-13 2x6 Flat 16oc
Type Wall
R -Value ........ 14 Hr-sf-F/Btu
Framing
Material ..... FIR.2X6.FLAT
Type .... Wood
Description .. 2x6 Fir Flat
Spacing ... .. 16 inches on center
Framing Frac.. 0.20
---------------------------------
Sketch of Construction Assembly
' LIST
OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
-------------
Description
----- -
R -Value R
-Value
0.
FILM.EX
---- ------------------------------
Exterior.air film: winter value
------------------
0.17
0.17
1.
STUCCO.0.88
0.875 in stucco
0.17
0.17
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
URETHANE.2.5
2.5 in cellular polyurethane.
14.00
--
3f.
FIR.2X6.FLAT
2x6 Fir Flat
--
3.00 -
4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
i
Total Unadjusted
--------- ---------
R -Values 15.53
4.53
FRAMING
i
ADJUSTMENT
CALCULATION
I
i-------------------
Cavity Framing
-------------------
Total
----------------
U -Factor:
(1 / 15.53 x 0.80) + (1 / 4.53 x0.20)
= 0.096 Btu/hr-sf-F
Total
R -Value:
1 / 0.096
= 10.46 hr-sf-F/Btu
CONSTRUCTION ASSEMBLY Page 4 3R
Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43
MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R
User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE
----------
------------------------------------------------------------------
------ Parallel Path Method
Reference Name . R.30.2X4.24
Description .... Roof R-30 2x4 24oc
Type ........... Roof
R -Value ........ 30 Hr-sf-F/Btu
Framing
Material ..... FIR.2X4
Type .... Wood
Description .. 2x4 fir
Spacing .... 24 inches on center
Framing Frac.. 0.07
---------------------------------
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Total Unadjusted R -Values
FRAMING ADJUSTMENT CALCULATION
Cavity
Material
R -Value
R -Value
---------
0.17
Name
-------------
Description
----------------------------------------
0.44
0.
FILM.EX
Exterior air film: winter
value
1.
SHNGL.ASPHLT
Asphalt shingle roofing
19.00
2.
BLDG.PAPER
Building paper (felt)
3.46
3.
PLY.0.50
0.50 in plywood
0.61
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
5.
BATT.RI9.0
R-19 batt insul (cavity >
5.5 in)
6c.
BATT.RII.0
R-11 batt insul (cavity >
3.5 in).
6f.
FIR.2X4
2x4 fir
7.
GYP.0.50
0.50 in gypsum or plaster
board
I.
FILM.IN.RF
Inside air film: heat flow straight up
Total Unadjusted R -Values
FRAMING ADJUSTMENT CALCULATION
Cavity
Frame
R -Value
R -Value
---------
0.17
---------
0.17
.0.44
0.44
0.06
0.06
0.62
0.62
0.80
0.80
19.00
19.00
11.00
--
--
3.46
0.45
0.45
0.61
0.61
33.15 25.62
Cavity Framing Total
------------------- ------------------- ----------------
U-Factor: (1 / 33..15 x 0.93) + (1 / 25.62 x 0.07) = 0.031 Btu/hr-sf-F
Total R -Value: 1 / 0.031 = 32.48 hr-sf-F/Btu
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... ROBERDES.EXISTING Date..12/03/03 10.30.19
Project Address........ 55-780 PEBBLE BEACH ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs, CA 92262
760-322-5004. Field Check/ Date
Climate Zone........ 15
---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
MICROPAS6 v6.01 File-23990EXT Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE
-------------------------------------------------------------------------------
=
-------------------------------
MICROPAS6 ENERGY USE
SUMMARY
=
= Energy Use
--------------------
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
Margin =
= Space Heating.......... 1.57
----------
1.70
---------- _
-0.13 =
= Space Cooling.......... 35.00
31.51
3.49 -
=
----
Total. 36.57
--------
33.21
-------- -
3.36 =
_ ***
----------------
Water Heating not calculated
GENERAL INFORMATION
Conditioned Floor Area..... 1098 sf
Building Type.............. Single Family Detached
Construction Type ......... Existing
Building Front Orientation. Front Facing 270 deg (W)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type........... FullYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
1
10980 cf
1098 sf
8.7 % of floor area
0.57 Btu/hr-sf-F
0.67
10 ft
BUILDING ZONE INFORMATION
-------------------------
Floor # of Vent Vent
Area. Volume Dwell Cond- Thermostat Height Area
Zone Type (sf) (cf) Units itioned Type (ft) (sf)
-------------- ------------ ----------------------- -------------
1.ZONE
Residence 1098 10980 1.00. Yes Setback 2.0 Standard
Air
Leakage
Credit
No
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... ROBERDES.EXISTING Date..12/03/03 10.30.19
MICROPAS6 v6.01 File-23990EXT Wth-CTZ15S92 Program -FORM C -2R
User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE
-------------------------------------------------------------------------------
OPAQUE SURFACES
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1.ZONE - Existing
6 SlabEdge 52 0.760 R-0 No
7 SlabEdge 10 0.510 R-0 No
Orientation
---------------------
-.ZONE - Existing
1 Window Left (N)
2 Window Left (N)
FENESTRATION SURFACES
---------------------
Area U- Act Exterior Shade Interior Shade
(sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC
----- ----- ----- --- ------------------ --------------
64.0 0.570 0.670' 0 90 Standard/0.76 Standard/0.68
32.0 0.570 0.670 0 90 Standard/0.76. Standard/0.68
SLAB SURFACES
-------------
Area
Slab Type (sf)
------- -----
1.ZONE
Standard Slab 1098
Area
U-
Insul
Act
------------
Refrigerant
Solar
Form 3 Location/
Surface.
--------------
(sf)
factor
R-val
Azm
Tilt
Gains
Reference Comments
1.ZONE -
------
Existing
-----
-----
---
----
-----
------------ ----------------
1 Wall
13
0.059
21
270
90
Yes
W.21.2X6.16
2 Wall
394
0.059
21
0
90
Yes
W.21.2X6.16
3 Wall
13
0.059
21
90
90
Yes
W.21.2X6.16
4 Wall
100
0.059
21
270
90
No
W.21.2X6.16
5 Roof
1098
0.031
30
n/a
0
Yes
R.30.2X4.24
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
1.ZONE - Existing
6 SlabEdge 52 0.760 R-0 No
7 SlabEdge 10 0.510 R-0 No
Orientation
---------------------
-.ZONE - Existing
1 Window Left (N)
2 Window Left (N)
FENESTRATION SURFACES
---------------------
Area U- Act Exterior Shade Interior Shade
(sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC
----- ----- ----- --- ------------------ --------------
64.0 0.570 0.670' 0 90 Standard/0.76 Standard/0.68
32.0 0.570 0.670 0 90 Standard/0.76. Standard/0.68
SLAB SURFACES
-------------
Area
Slab Type (sf)
------- -----
1.ZONE
Standard Slab 1098
ACCA
Manual Duct
D Eff
No 0.770
No 0.626
SPECIAL FEATURES AND -MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC-specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
HVAC SYSTEMS
------------
Refrigerant
Tested
System
Minimum Charge and Duct
Duct
Duct
Type
-------------
Efficiency Airflow Location
-------------------------------
R -value
Leakage
1.ZONE
-------
---------
Furnace
0.800 AFUE n/a Attic
R-6
No
ACSplit
12.25 SEER No Attic
R-6
No
ACCA
Manual Duct
D Eff
No 0.770
No 0.626
SPECIAL FEATURES AND -MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC-specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Duct R -value.
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... ROBERDES.EXISTING Date..12/03/03 10:30:19
MICROPAS6 v6.01 File-23990EXT Wth=CTZ15S92 Program -FORM C-2R
User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE
----------
---------------------------------------------------
REMARKS
The values and.materials used in this existing house calculation
are based on Title 24 compliance calculations by Madlin's
Enterprises dated 6/1995.
The HVAC load calculations included in this compliance report
are for permit purposes only. The installing HVAC contractor
is responsible for determing the HVAC design loads and
equipment selection(s). The HVAC design shall be done in accord-
ance with industry standards. The load calculation in this
report considers ambient temperature load, solar gain,
people and a fixed latent heat gain percentage. This basic
Toad must be adjusted for additional design conditions and
system/equipment performance.
The installing glazing contractor shall provide the required
CF -6R Installation Certificate with installed glazing values
and areas.
The HVAC equipment is existing.
The night setback thermostat is existing.
The water heaters are existing.
Madlin s
erste rises
Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ®®®®®®
r
H. V.A. C. Load Calculation
4
1
'
- 5 ,
HVAC SIZING Page 1 HVAC
Project Title.......... ROBERDES.ALTERATIONDate..12/03/03 10:55:32
Project Address........ 55-780 PEBBLE BEACH_ ******* ---------------------
PGA WEST LA QUINT *v6.01*
Documentation Author... CATHERINE M. MADLIN ******* Building Permit
Madlin's Enterprises
P.O. Box 1443 Plan Check Date
Palm Springs,.CA. 92262
760-322-5004. Field Check/ Date .
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-----------------
MICROPAS6 v6.01 File-23990ALT Program -HVAC SIZING
User#-MP0207 User-Madlin s Enterprises Run -ALTERED SPACE
------------------------
-------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area.......... ..... 1098 sf
Volume:. 10980 cf
Front Orientation.......... Front Facing 270 deg (W)
Sizing Location..... ..... PALM DESERT
Latitude... .. 33.7 degrees
Winter Outside Design...... 32 F
Winter Inside Design.:..._ 70 F
Summer Outside Design...... 112 F
Summer Inside Design....... 78 F
Summer Range.. ... . 34 F
Interior Shading Used No
Exterior Shading Used...... No
Overhang Shading Used...... No
Latent Load Fraction....... 0.20
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating Cooling
Description (Btuh) (Btuh)
-------------- ------------------- ----------- -----------
Opaque Conduction and Solar...... 4425 2980
Glazing Conduction .:............. 2256 2018
Glazing Solar .................... n/a 1030 -
Infiltration .......... 5798 3837
Internal Gain........... ....... n/a 450
Ducts. ......................... 1248 1032
Sensible�Load.................. 13726 11347
Latent Load....... ..... n/a 2269
----------- -----------
Minimum Total Load 13726 13616
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment.. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all