Loading...
0312-041 (AR)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force•and effect. ,-! J� ; License # Lic. Class Exp. Date 104183 A , �,I13►�2c Date ' �� Signature of Contractor �*r , }�� Y' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier STA1 E 1d)y1n Policy No. 1.542568-201)* .3 section need not be completed if the permit valuation is for $100.00 or less). () I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agreeithat,'if I should become subject to the workers' compensation provisions of Section 3700$1of the Labor Code, I shall forthwith comply with those provisions Date: f - / ^ t Applicant s <r - / 4; C % Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize rep resentativesrof'this City to enter upon the above-mentioned propertyafor inspectionpurpo'seS. /F Signature (Owner/Agent),Y. 'L r- � ��j �[I Date j BUILDING PERMIT PERMIT# ff�'i2-fkdi DATE 0i/0SX VALUATION S2.00001 LOT 35 TRACT 2,0717YU18 JOB SITE ADDRESS ;552 80 I3: �)7� BEACH APN _ ^ OWNER CONTRACTOR / DESIGNER / ENGINEER N IINEER yy- �yOrrFAM CBR E1;i , XiC0, ?•7ryR , 55•ef3Cf s'E :323? r' 7sAi;H 54015 "501 )115:�,F:NFILL1Z IA QUMP1'A C:A. 92:53 1A QUWA CA 92253 (160)771-1877 CLIL4 5620 USE OF PERMIT RI?.S.€U)7rI>1V_AL ADD I7. O.H REVISION TO 103 EVATRIUM irk CJ DSURE PP"5 101JSLY i•'Es'WI`ITTED(0309-121),2001 C130. 'VALUATION 4000.00 L3 PW CHECK FEF 101.0110.439.318 $29,25 CONSTRUCTION FEE 101.OW-41$-000 !45.00 S1 RO140 MOTION FEE - ItESID 101.000.241-000 Q D 07 2004 C1 r., C.- Lt. r1-�rro "E r SUD-TtXALCOI+%'I!'RIMMON AND PLAN I.= PRE -PAM 179L. S $0100 T(Y.CAL PKT?M 'FFCYS DUE nOW S74.7 5 RECEIPT DATE %' L 0 BY. " r 1 NALE L(. D It PECTOR vv'' INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE • INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground P1bg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: -- Total Permit Fees L ew r Bit1 # \ '. Permit # K 0$ ' O / �3 City of La Quinta Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address-�J'� D Owttcr's Name: A. P. Number: Address: X x Legal Description: Contractor.C- M Address: City. ST. Zip: CJS✓` r ,., •• _ , ]<Telephone: XProject Description: J� X City, ST. Zip: Telephone: 1/VV) uS�b� O �tx�s'i-ttn A State Lic. # : � City Lic. #: Arch., Engr., Designer. Address: StA 0,J9 City. ST. Zip: X X Telephone.. State Lic. #: Name of Contact Person:C2 Telephone # of Contact Person: ( Construction Type= y _ Occupancy: Project type (circle one): New Add'n Alter Repair Demo S Sq. Ft.: #Stories: #Units: stimated Value of Proiect: APPLICANT: DO NOT WRITE BELOW THIS LINE q Submittal Req'd Rec'd TRACKING PERMIT FEES Amount Plan Secs A Plan Check submitted l' Item Plan Check Deposit Structural Cales. Reviewed, ready for corrections Plan Check Balance Truss Cales. Catled Contact Person Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionstissue Electrical Subcontactor List Called Contact Person ' Plumbing Grant Deed Plans picked up s.nl.l. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correcti srssue / b Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 6 School Fees Total Permit Fees A kej 9) %M= 0 eo Y, c�so- C. ( o e TITLE 24 Energy Conservation Standards Compliance Report, t . ROBERDES RES. ALTERATION 54-015 SOUTHERN HILLS PGA WEST - LA QUINTA December 3, 2003 Job•'Number: 23990A CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED eneral Contractor: FOR CONST UCTION CBR, INC. DA ROBERDES DAAIOI_0855 `W SHINGTON STREET INI A, CA 92253. 760-771-2278 . . Madlin S. � enterprises ®®®®v® Catherine M. Madlin, Certified Energy Analyst. Post Office Box 1443 ® Palm Springs, CA 92263 760-322-5004 / 323-3644, (fax) - E-mail: GMadlin@aol.com 5s-aao P� bbd $ems- a?v 156" CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 ' CF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- . PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262• 760-322-5004 Field Checkl Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ----------------------------- MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP6207 User-Madlin's Enterprises Run -ALTERED SPACE ----------------------------------------=-------------------------------------- j GENERAL INFORMATION ' ------------------- Conditioned Floor Area...... 1098 sf j Building Type .............. Single Family Detached Construction Type ......... Existing Plus Alteration' Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 ' ( Floor Construction Type...." Slab On Grade j Glazing Percentage......... 7.6 8 of floor area Average Glazing U -factor... 0.72 Btu/hr-sf-F Average Glazing SHGC....... 0.69 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION Component ------------------------- Frame Cavity Sheathing Total Assembly Type Type R -value R -value R -value U -factor Location/Comments ---------=-- • Wall ------------------------------------- ------------------------ Wood R-21 R-0 R-21 0.059 EXISTING WALLS i Wall Wood R-17.8 R-0 R-17.8 . 0.065 NEW WALL WALL FILL-IN Wall Wood R-14 R-0 R-14 0.096 SPECIAL WALL Roof Wood R-11 R-19 R-30 0.031' S1abEdge None R-0 R-0 F2=0.760 S1abEdge None R-0 R-0 F2=0.510 j FENESTRATION j Over - Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins -------------------- Door ----- ------ ----------------------------------- Left (N) 35.0 0.850 0.700 Standard Standard ----- None s Window Left (N) 15.0 0.720 0.730 Standard Standard None Window Left (N) 33.0 0.570 0.670 Standard Standard None i " SLAB SURFACES -------------Area Slab Type (sf) ---------------- ------ Standard Slab 1098 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R --------------- ------------- ________ Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ---------------------------------------------7--------------------------------- HVAC SYSTEMS ------------ Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R -value Leakage D Type ------------ -------------------------------------------- ------ ---------- Furnace 0.800 AFUE n/a Attic R-6 No No Setback ACSplit 12.25 SEER No Attic R-6 No No Setback SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. REMARKS The values and materials used in this existing house calculation are based on Title 24 compliance calculations by Madlin's Enterprises dated 6/1995. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. The HVAC equipment is existing. The night setback thermostat is existing. The water heaters are existing. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 MICR0PAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... DAVID ROBERDES Name.... CATHERINE M. MADLIN Company. CBR, INC. Company. Madlin's Enterprises Address. 50855 WASHINGTON #C201 Address. P.O. Box 1443 PGA WEST LA QUINT LA QUINTA, CA 92253 Palm Springs, CA 92262 Phone... 760-771-2278 Phone... 760-3 2-5004 License. d Signed.. Signed.. Plan -Check Mate) (date) ENFORCEMENT AGENCY Name.... Certified Energy analyst. Title... Catherine M. Madlin Agency.. NR 98-90.544 r r R 98-90.144 Phone... rr Signed.. C A D E C (date) Cdifanfo an of ONlding Eneigy ConwUorn MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 ___________________________ MF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan -Check Date Palm Springs, CA 92262 760-322-5004 Field C ec Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ---------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used.' Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150,(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R -Value. *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.38, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control C. Flue damper and control 2. No continuous burning gas pilots allowed. NA NA NA r MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2MF-1R -------------- ___________________________________________________________________________ Project Title.......... ROBERDES.ALTERATION............. Date..12/03/03 10:29:43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-113: HVAC equipment, water heaters, showerheads and New faucets certified by the Commission. oni� 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Setback thermostat on all applicable heating and/or cooling systems. _Xr& 150'(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation i having an installed thermal resistance of R-12 or greater. i2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated(R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or i other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. f 6. Piping insulated between heating source and indirect hot water tank. EKTC, *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a . minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually New operated dampers. a vc 114: Pool and Spa Heating Systems and Equipment I 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. j b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heateFs, spa heaters or household cooking appliances have no continuously burning MANDATORY MEASURES CHECKLIST: RESIDENTIAL -----------------Page -3----------MF_1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 ---------------------------------- MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF_ 1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- j pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). eM., LIGHTING MEASURES ----------------- 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. Design- Enforce- er ment ,JIA Ma in s enterptises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ....... Title 24 Energy Conservation Standards Compliance Report r This proposed project has been reviewed for compliance with the 2001 State of California Energy Conservation Standards, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. Date: December 3, 2003 Job Number: 23990A General Contractor: CBR, INC. / DAVID ROBERDES Owner's Name: CHANG ROBERDES Project Name: ,ROBERDES RESIDENTIAL ALTERATION Project Location: 54-015 SOUTHERN HILLS - PGA WEST - LA QUINTA Method of Compliance: MICROPAS V6.1 CERTIFIED COMPUTER PROGRAM Orientation Of Entry: WEST - SEE SITE PLAN Certified Energy Analyst Catherine M. Madlin NR 98-90-544 r r R 98-90-144 rr C A 8 E C California Association of Building Energy Consultants v. Post Office Box 1443 v Palm Springs, Ca 92263 v v Post Office Box 1443 v Palm Springs, Ca 92263 v MaIn s. enterpnses Catherine M. Madfin, Certified Energy Analyst v 760-322-5004 L 323-3644 (fax) vvvvvvv ..................... .............. ...... .............. . .... .... .................... D DRIP TI INC20.. .. ................................ -X .... b.. ON: ........................... ......................... .. .. .......... Job Name ROBERDES RESIDENTIAL ALTERATION Job No. / File No. 23990A Method of Compliance Micropas V6.1 Computer Simulation Existing -Plus -Alteration Calculation Method Insulation: Roof Ceiling Existing Insulation: Walls Exterior Wall Fill-ins: R-19 Special Thin Wall: R-14 - Polyurethane Insulation: Floor - Slab on Grade Not Required Insulation: H.V.A.C. Ducts/Location/Testing Existing Ducts Glazing U Value / Type: French Door 0.85,'Dual Pane, Aluminum Frame (CEC Default Value) Glazing U -Value / Type: Fixed 0.72, Dual Pane, Low E2, Aluminum Frame (CEC Default Value) Glazing U -Value / Type: Glass Block 0.57 (CEC Default Value) Glazing- Solar Heat Gain Coefficient (Uncoated) 0.70 Fr.Dr. / 0.73 Fixed Glass Block Clear Glazing: Exterior Shading Not Required Thermal Mass Square Footage & % Not Required H.V.A.C. System Type Existing Equipment Domestic Hot Water Heater Existing Equipment Other Requirements Applicable Mandatory Measures v Post Office Box 1443 v Palm Springs, Ca 92263 v i Madlin s - enterprises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 &x) Title 24 Compliance Forms CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R ----- -------------------------------------------------- Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method ....... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ------------------------------------------------------- ----------------------------- MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------=------------------------ GENERAL INFORMATION Conditioned Floor Area..... 1098 sf Building Type .............. Single Family Detached Construction Type ......... Existing Plus Alteration Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Glazing Percentage......... 7.6 % of floor area Average Glazing U -factor... 0.72 Btu/hr-sf-F Average Glazing SHGC....... 0.69 Average Ceiling Height..... 10 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type ------------ Type ------- R -value R -value. R -value U -factor Location/Comments Wall Wood -------- R-21 ---------------------- R-0 R-21 0.059 - -------------------- EXISTING WALLS Wall Wood R-17.8 R-0 R-17.8 0.065 NEW WALL WALL FILL-IN Wall Wood R-14 R-0 R-14 0.096 SPECIAL WALL Roof Wood R-11 R-19 R-30 0.031 S1abEdge None R-0 R-0 F2=0.760 S1abEdge i None R-0 R-0 F2=0.510 j FENESTRATION j Over - Area U- Interior Exterior hang/ Orientation I (sf) Factor SHGC Shading Shading Fins Door Left (N) 35.0 0.850 0.700 Standard Standard None Window, Left (N) 15.0 0.720 0.730 Standard Standard None Window Left (N) 33.0 0.570 0.670 Standard Standard None i SLAB SURFACES ------------- Area Slab Type (sf) i i Standard Slab 1098 . CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- HVAC SYSTEMS SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer. -and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. REMARKS The values and materials used in this existing house calculation are based on Title 24 compliance calculations by Madlin's Enterprises dated 6/1995. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage.. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. - The HVAC equipment is existing. The night setback thermostat is existing. The water heaters are existing. Refrigerant Tested ACCA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type ------------ Efficiency ------------ Airflow Location ------------------ R -value Leakage D Type Furnace 0.800 AFUE n/a Attic ------- R-6 ------- No ------ No ---------- Setback ACSplit 12.25 SEER No Attic R-6 No No Setback SPECIAL FEATURES AND MODELING ASSUMPTIONS ------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer. -and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. REMARKS The values and materials used in this existing house calculation are based on Title 24 compliance calculations by Madlin's Enterprises dated 6/1995. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage.. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. - The HVAC equipment is existing. The night setback thermostat is existing. The water heaters are existing. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM CF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with'Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations. to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER Name.... DAVID ROBERDES Company. CBR, INC. Address. 50855 WASHINGTON #C201 LA QUINTA, CA 92253 Phone... 760-771-2278 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... CATHERINE M. MADLIN Company. Madlin's Enterprises Address. P.O. Box 1443 Palm Springs, CA 92262 Phone... 760-322-5004 Signed.. (date F Certified Energy Analyst Catherine M. Madlin NR 98.90-W r r R 9&90-144 rr �CABEC California Association of Building Energy Conaftm MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF-1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29:43 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan C ec Date Palm Springs, CA 92262 760-322-5004 Field Che --c Date Climate Zone ........ •... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. __________________________ MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R ! I User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ----------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturer's labeled R -Value. ` *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). Design- Enforce- erment I/ N/A *150(a): Minimum 'R-13 raised floor insulation in framed floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets insulation quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. .150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets Commission quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. A1/4 /yA NA MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce - 110 -113: HVAC equipment, water heaters, showerheads and r faucets certified by the Commission. dAh- .150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ✓ 150(i): Setback thermostat on all applicable heating and/or cooling systems. E�T� 150(j): Pipe and Tank -insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external ' insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used.for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber ' addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2.. Exhaust fan.systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have i either automatic or readily accessible, manually NSW operated dampers. OWL i 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36 inches of pipe between filter and heater for .future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:29.43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM MF -1R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr). C'x7Z� LIGHTING MEASURES ----------------- 150(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy of 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be'controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and -recessed ceiling fixtures are IC (insulation cover) approved. Design- Enforce- er ment /,l A Remodeled Building ADDITION WORKSHEET Page 1 ADD ------------------------------------------------------- Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10:30:19 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 by Enercomp, Inc. ------- ____________________________________________ MICROPAS6 v6.01 File-23990EXT Program -ADDITIONS User#-MP0207. User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE ------------- ; File Name. ..... ........ 23990EXT - EXISTING SPACE Conditioned Floor Area..... 1098 sf Standard Design Energy Use. 36.57 kBtu/sf-yr Proposed Design Energy Use. 33.21 kBtu/sf-yr NEW (EXISTING PLUS ADDITION/ALTERATION) File Name. .............. 23990ALT - ALTERED SPACE Conditioned Floor Area..... 1098 sf Standard Design Energy Use. 36.97 kBtu/sf-yr Proposed Design Energy Use. 34.11 kBtu/sf-yr. FLOOR AREA RATIO Floor Existing New Area Floor Area Floor Area Ratio ---------- 1098 ------------- / 1098 ------- = 1.000 DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION/ALTERATION) Floor Addition/ New Area Existing Existing Alteration Standard ------------- Ratio ------- Proposed -------- Standard Design 36.97 + 1.000 x ( 0.00 - -------- 0.00) -------- 36.97 Note: If (Existing Proposed - Existing Standard) is negative, this difference is set to zero. ------------------------------------------------ = ADDITION/ALTERATION ENERGY USE SUMMARY = ------------------- - Addition/ Energy Use Alteration Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = ------------------------------------------------------ _ New .................... 36.97 34.11 2.86 = *** Addition/Alteration complies with Computer Performance *** _ COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan C ec Date Palm Springs, CA' 92262 760-322-5004 Field Check/ Date Climate Zone........... 15 --------------------- C ompliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. i I MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- MICROPAS6 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 1.62 1.97 -0.35 = = Space Cooling.......... 35.35 32.14 3.21 - 1.ZONE ------ Total 36.97 -------- 34.11 -------- .2.86 _ *** water Heating not calculated 1.00 Yes Setback 2.0 GENERAL INFORMATION Conditioned Floor Area...,. 1098 sf Building Type .............. Single Family Detached Construction Type ......... Existing Plus Alteration Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 10980 cf Slab -On -Grade Area......... 1098 sf Glazing Percentage......... 7.6 % of floor area Average Glazing U -factor... 0.72 Btu/hr-sf-F Average Glazing SHGC....... 0.69 Average Ceiling Height..... 10 ft BUILDING ZONE INFORMATION Floor # of. Vent Vent Air Area Volume Dwell Cond- Thermostat Height Area Leakage Zone Type (sf) (cf) -------------- ------------ Units itioned Type (ft) (sf) Credit 1.ZONE ----------------------- ----- -------- --------- Residence 1098 10980 1.00 Yes Setback 2.0 Standard No COMPUTER METHOD SUMMARY U- - Act Exterior Shade Page 2 C -2R Project Title.......... ROBERDES.ALTERATION factor SHGC ----- Date..12/03/03 10.29.43 Tilt MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM C -2R ------------------------------------------------------------------------------- User#-MP0207 User-Madlin's -------------- Enterprises 35.0 Run -ALTERED SPACE 0 90 Standard/0.76 Standard/0.68 OPAQUE SURFACES 0.720 0.730 0 90 Area U- --------------- Insul Act 0.570 0.670 Solar Form 3 Location/ Surface -------------- ------ (sf) factor R-val Azm Tilt Gains Reference Comments 1.ZONE ----- ----- --- ---- ----- ------------ ---------------- 1 Wall 13 0.059 21 270 90 Yes W.21.2X6.16 EXISTING WALLS 2 Wall 321 0.059 21 0 90 Yes W.21.2X6.16 3 Wall 13 0.059 21 90 90 Yes W.21.2X6.16 4 Wall 100 0.059 21 270 90 No W.21.2X6.16 5 Wall 6 0.065 17.8 270 90 Yes W.19.2X6.16 NEW WALL j 6 Wall 32 0.065 17.8 0 90 Yes W.19.2X6.16 WALL FILL-IN i 7 Wall 10 0.065 17.8 '90 90 Yes W.19.2X6.16• NEW WALL 8 Wall 88 0.096 14 0 90 Yes W.13.2.5.FLT SPECIAL WALL 9 Roof 1098 0.031 30 n/a 0 Yes R.30.2X4.24 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE 10 S1abEdge 52 0.760 R-0 No 11 S1abEdge 10 0.510 R-0 No FENESTRATION SURFACES System Type ------------- 1.ZONE Furnace ACSplit HVAC SYSTEMS ------------ Refrigerant Tested ACCA Minimum Charge and Duct Duct Duct Manual Duct Efficiency Airflow Location R -value Leakage D Eff ---------------------------------------- ---- 0.800 AFUE n/a Attic R-6 No No 0.770 12.25 SEER No Attic R-6 No No 0.626 Area U- - Act Exterior Shade Interior Shade Orientation ---------------------- (sf) ----- factor SHGC ----- Azm Tilt Type/SHGC Type/SHGC 1.ZONE ----- --- ---- -------------- -------------- 1 Door Left (N) 35.0 0.850 0.700 0 90 Standard/0.76 Standard/0.68 2 Window Left (N) 15.0 0.720 0.730 0 90 Standard/0.76 Standard/0.68 3 Window Left (N) 33.0 0.570 0.670 0 90 Standard/0.76 Standard/0.68 SLAB SURFACES ------------- Area Slab Type ---------------- (sf) 1.ZONE ------ Standard Slab 1098 System Type ------------- 1.ZONE Furnace ACSplit HVAC SYSTEMS ------------ Refrigerant Tested ACCA Minimum Charge and Duct Duct Duct Manual Duct Efficiency Airflow Location R -value Leakage D Eff ---------------------------------------- ---- 0.800 AFUE n/a Attic R-6 No No 0.770 12.25 SEER No Attic R-6 No No 0.626 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE. ------------------------------------------------------------------------------- s SPECIAL FEATURES AND.MODELING ASSUMPTIONS -------------------------- --------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. REMARKS The values and materials used in this existing house calculation are based on Title 24 compliance calculations by Madlin's Enterprises dated 6/1995. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor i is responsible for determing the HVAC design loads and j equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage. This basic load must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. The HVAC equipment is existing. The night setback thermostat is existing. The water heaters•are existing. CONSTRUCTION ASSEMBLY Page 1 3R. Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 _____________________________________________________ MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE -------------------------------------------------=----------------------------- Parallel Path Method Reference Name . W.21.2X6.16 Description .... Wall R-21 2x6 16oc Type ........... Wall R -Value 21 Hr=sf-F/Btu Framing Material ..... FIR.2X6 Type - .... Wood Description .. 2x6 fir Spacing ...... 16 inches on center Framing Frac.. 0.15 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame i------------- Name Description ---------------------------------------- R -Value R -Value 0. FILM.EX Exterior air film: winter value ------------------ 0.17 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17, 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R21 R-21 batt insul (.cavity = 5.5 in) 21.00 -- 3f.. FIR.2X6 2x6 fir -- 5.45 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 --------- --------- Total Unadjusted R -Values 22.54 6.98 FRAMING ADJUSTMENT CALCULATION i Cavity Framing Total U -Factor: (1 / 22.54 x 0.85) + (1 / 6.98 x 0.15) = 0.059 Btu/hr-sf-F Total i i R -Value: 1'/ 0.059 = 16.89 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 2 3R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 MICROPAS6 v6.01 File-2399.0ALT Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------- --------------- Parallel Path Method Reference Name . W.19.2X6.16 Description .... Wall R-19 2x6 16oc Type Wall R -Value ........ 17.8 Hr-sf-F/Btu Framing Material ..... FIR.2X6 Type ..... Wood Description .. 2x6 fir Spacing .... 16 inches on center Framing Frac.. 0.15 -----------------------.---------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------------------------------------- U-Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-.F Total R -Value: 1 / 0.065 = 15.28 hr-sf-F/Btu Material Cavity Frame Name ------------- Description ---------------------------------------- R -Value R-Value 0. FILM.EX Exterior air film: winter value --------- 0.17 --------- 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R19 R-19 batt insul (cavity = 5.5 in) 17.80 -- 3f. FIR.2X6 2x6 fir -- 5.45 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values --------- 19.34 --------- 6.98 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ------------------------------------------------- U-Factor: (1 / 19.34 x 0.85) + (1 / 6.98 x 0.15) = 0.065 Btu/hr-sf-.F Total R -Value: 1 / 0.065 = 15.28 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 3 3R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29:43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ------------------------------------------------------------------------------ ---- Parallel Path Method Reference Name . W.13.2.5.FLT Description Wall R-13 2x6 Flat 16oc Type Wall R -Value ........ 14 Hr-sf-F/Btu Framing Material ..... FIR.2X6.FLAT Type .... Wood Description .. 2x6 Fir Flat Spacing ... .. 16 inches on center Framing Frac.. 0.20 --------------------------------- Sketch of Construction Assembly ' LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name ------------- Description ----- - R -Value R -Value 0. FILM.EX ---- ------------------------------ Exterior.air film: winter value ------------------ 0.17 0.17 1. STUCCO.0.88 0.875 in stucco 0.17 0.17 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. URETHANE.2.5 2.5 in cellular polyurethane. 14.00 -- 3f. FIR.2X6.FLAT 2x6 Fir Flat -- 3.00 - 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 i Total Unadjusted --------- --------- R -Values 15.53 4.53 FRAMING i ADJUSTMENT CALCULATION I i------------------- Cavity Framing ------------------- Total ---------------- U -Factor: (1 / 15.53 x 0.80) + (1 / 4.53 x0.20) = 0.096 Btu/hr-sf-F Total R -Value: 1 / 0.096 = 10.46 hr-sf-F/Btu CONSTRUCTION ASSEMBLY Page 4 3R Project Title.......... ROBERDES.ALTERATION Date..12/03/03 10.29.43 MICROPAS6 v6.01 File-23990ALT Wth-CTZ15S92 Program -FORM 3R User#-MP0207 User-Madlin's Enterprises Run -ALTERED SPACE ---------- ------------------------------------------------------------------ ------ Parallel Path Method Reference Name . R.30.2X4.24 Description .... Roof R-30 2x4 24oc Type ........... Roof R -Value ........ 30 Hr-sf-F/Btu Framing Material ..... FIR.2X4 Type .... Wood Description .. 2x4 fir Spacing .... 24 inches on center Framing Frac.. 0.07 --------------------------------- Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Material R -Value R -Value --------- 0.17 Name ------------- Description ---------------------------------------- 0.44 0. FILM.EX Exterior air film: winter value 1. SHNGL.ASPHLT Asphalt shingle roofing 19.00 2. BLDG.PAPER Building paper (felt) 3.46 3. PLY.0.50 0.50 in plywood 0.61 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 5. BATT.RI9.0 R-19 batt insul (cavity > 5.5 in) 6c. BATT.RII.0 R-11 batt insul (cavity > 3.5 in). 6f. FIR.2X4 2x4 fir 7. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.RF Inside air film: heat flow straight up Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Frame R -Value R -Value --------- 0.17 --------- 0.17 .0.44 0.44 0.06 0.06 0.62 0.62 0.80 0.80 19.00 19.00 11.00 -- -- 3.46 0.45 0.45 0.61 0.61 33.15 25.62 Cavity Framing Total ------------------- ------------------- ---------------- U-Factor: (1 / 33..15 x 0.93) + (1 / 25.62 x 0.07) = 0.031 Btu/hr-sf-F Total R -Value: 1 / 0.031 = 32.48 hr-sf-F/Btu COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... ROBERDES.EXISTING Date..12/03/03 10.30.19 Project Address........ 55-780 PEBBLE BEACH ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs, CA 92262 760-322-5004. Field Check/ Date Climate Zone........ 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-23990EXT Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE ------------------------------------------------------------------------------- = ------------------------------- MICROPAS6 ENERGY USE SUMMARY = = Energy Use -------------------- Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design Margin = = Space Heating.......... 1.57 ---------- 1.70 ---------- _ -0.13 = = Space Cooling.......... 35.00 31.51 3.49 - = ---- Total. 36.57 -------- 33.21 -------- - 3.36 = _ *** ---------------- Water Heating not calculated GENERAL INFORMATION Conditioned Floor Area..... 1098 sf Building Type.............. Single Family Detached Construction Type ......... Existing Building Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type........... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Slab On Grade 1 10980 cf 1098 sf 8.7 % of floor area 0.57 Btu/hr-sf-F 0.67 10 ft BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Vent Area. Volume Dwell Cond- Thermostat Height Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) -------------- ------------ ----------------------- ------------- 1.ZONE Residence 1098 10980 1.00. Yes Setback 2.0 Standard Air Leakage Credit No COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... ROBERDES.EXISTING Date..12/03/03 10.30.19 MICROPAS6 v6.01 File-23990EXT Wth-CTZ15S92 Program -FORM C -2R User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE ------------------------------------------------------------------------------- OPAQUE SURFACES PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE - Existing 6 SlabEdge 52 0.760 R-0 No 7 SlabEdge 10 0.510 R-0 No Orientation --------------------- -.ZONE - Existing 1 Window Left (N) 2 Window Left (N) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ------------------ -------------- 64.0 0.570 0.670' 0 90 Standard/0.76 Standard/0.68 32.0 0.570 0.670 0 90 Standard/0.76. Standard/0.68 SLAB SURFACES ------------- Area Slab Type (sf) ------- ----- 1.ZONE Standard Slab 1098 Area U- Insul Act ------------ Refrigerant Solar Form 3 Location/ Surface. -------------- (sf) factor R-val Azm Tilt Gains Reference Comments 1.ZONE - ------ Existing ----- ----- --- ---- ----- ------------ ---------------- 1 Wall 13 0.059 21 270 90 Yes W.21.2X6.16 2 Wall 394 0.059 21 0 90 Yes W.21.2X6.16 3 Wall 13 0.059 21 90 90 Yes W.21.2X6.16 4 Wall 100 0.059 21 270 90 No W.21.2X6.16 5 Roof 1098 0.031 30 n/a 0 Yes R.30.2X4.24 PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments ------------ --------------------- ----- ---------------------- 1.ZONE - Existing 6 SlabEdge 52 0.760 R-0 No 7 SlabEdge 10 0.510 R-0 No Orientation --------------------- -.ZONE - Existing 1 Window Left (N) 2 Window Left (N) FENESTRATION SURFACES --------------------- Area U- Act Exterior Shade Interior Shade (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC ----- ----- ----- --- ------------------ -------------- 64.0 0.570 0.670' 0 90 Standard/0.76 Standard/0.68 32.0 0.570 0.670 0 90 Standard/0.76. Standard/0.68 SLAB SURFACES ------------- Area Slab Type (sf) ------- ----- 1.ZONE Standard Slab 1098 ACCA Manual Duct D Eff No 0.770 No 0.626 SPECIAL FEATURES AND -MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC-specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. HVAC SYSTEMS ------------ Refrigerant Tested System Minimum Charge and Duct Duct Duct Type ------------- Efficiency Airflow Location ------------------------------- R -value Leakage 1.ZONE ------- --------- Furnace 0.800 AFUE n/a Attic R-6 No ACSplit 12.25 SEER No Attic R-6 No ACCA Manual Duct D Eff No 0.770 No 0.626 SPECIAL FEATURES AND -MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC-specifications, and *** *** verified during plan check and field inspection. *** This building incorporates non-standard Duct R -value. COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... ROBERDES.EXISTING Date..12/03/03 10:30:19 MICROPAS6 v6.01 File-23990EXT Wth=CTZ15S92 Program -FORM C-2R User#-MP0207 User-Madlin's Enterprises Run -EXISTING SPACE ---------- --------------------------------------------------- REMARKS The values and.materials used in this existing house calculation are based on Title 24 compliance calculations by Madlin's Enterprises dated 6/1995. The HVAC load calculations included in this compliance report are for permit purposes only. The installing HVAC contractor is responsible for determing the HVAC design loads and equipment selection(s). The HVAC design shall be done in accord- ance with industry standards. The load calculation in this report considers ambient temperature load, solar gain, people and a fixed latent heat gain percentage. This basic Toad must be adjusted for additional design conditions and system/equipment performance. The installing glazing contractor shall provide the required CF -6R Installation Certificate with installed glazing values and areas. The HVAC equipment is existing. The night setback thermostat is existing. The water heaters are existing. Madlin s erste rises Catherine M. Madlin, Certified Energy Analyst . 760-322-5004 / 323-3644 (fax) ®®®®®® r H. V.A. C. Load Calculation 4 1 ' - 5 , HVAC SIZING Page 1 HVAC Project Title.......... ROBERDES.ALTERATIONDate..12/03/03 10:55:32 Project Address........ 55-780 PEBBLE BEACH_ ******* --------------------- PGA WEST LA QUINT *v6.01* Documentation Author... CATHERINE M. MADLIN ******* Building Permit Madlin's Enterprises P.O. Box 1443 Plan Check Date Palm Springs,.CA. 92262 760-322-5004. Field Check/ Date . Climate Zone........... 15 --------------------- Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. ----------------- MICROPAS6 v6.01 File-23990ALT Program -HVAC SIZING User#-MP0207 User-Madlin s Enterprises Run -ALTERED SPACE ------------------------ ------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area.......... ..... 1098 sf Volume:. 10980 cf Front Orientation.......... Front Facing 270 deg (W) Sizing Location..... ..... PALM DESERT Latitude... .. 33.7 degrees Winter Outside Design...... 32 F Winter Inside Design.:..._ 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range.. ... . 34 F Interior Shading Used No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) (Btuh) -------------- ------------------- ----------- ----------- Opaque Conduction and Solar...... 4425 2980 Glazing Conduction .:............. 2256 2018 Glazing Solar .................... n/a 1030 - Infiltration .......... 5798 3837 Internal Gain........... ....... n/a 450 Ducts. ......................... 1248 1032 Sensible�Load.................. 13726 11347 Latent Load....... ..... n/a 2269 ----------- ----------- Minimum Total Load 13726 13616 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment.. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.