Loading...
BRES2017-0126LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 748605 000-1 Dates er �7 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business'and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a& permit subjects the applicant to a civil penalty of not more than five hundred dollars �) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the,projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY . I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the,Work for which this permit is issued. e TW -1 -have and will maintain workers' compensation insurance, as required by )lection 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 1889409 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so.as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. _ 1 i WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that -the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. DD:�Signature (Applicant or Agent)—,,,_ i 78-495 CALLE TAMPICO 4 VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX FAX (760 ) 777-7011 DESIGN &DEVELOPMENT DEPARTMENT (760) 777-7153 BUILDING PERMIT Date: 7/17/201.7 Application Number: BRES2017-0126 " Owner: Property Address: 81115 GOLF VIEW DR DOUGLAS SABELLA APN: 762280011 Application Description: SABELA / 245SF PATIO CONVERSION TO DINING ROOM 92253 Property Zoning: Application Valuation: $37,500.00 C� z w fi Applicant:Contractor: c a LANG CONSTRUCTION LANG CONSTRUCTION N 80590 CAMINO SAN GREGORIO 80590 CAMINO SAN GREGORIO O LU INDIO, CA 92203 INDIO, CA 92203 L 2 , (760)702-7744 --------------------------------------------------------------------------------------------- Llc. No.: 748605 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 748605 000-1 Dates er �7 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business'and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a& permit subjects the applicant to a civil penalty of not more than five hundred dollars �) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the,projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY . I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the,Work for which this permit is issued. e TW -1 -have and will maintain workers' compensation insurance, as required by )lection 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 1889409 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so.as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. _ 1 i WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that -the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. DD:�Signature (Applicant or Agent)—,,,_ Applicant: Contractor: LANG CONSTRUCTION LANG CONSTRUCTION 80590 CAMINO SAN GREGORIO 80590 CAMINO SAN GREGORIO INDIO, CA 92203 INDIO, CA 92203 (760)702-7744 Llc. No.: 748605 -------------------------------------------------'-------------------------------------------- Detail: 245SF PATIO CONVERSION TO DINING ROOM [ENGINEERED) THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF HVAC SYSTEMS, ALTERATIONS TO PLUMBING INSTALLATIONS OR REMODEL TO THE EXISTING DWELLING AREAS. 2016 CALIFORNIA BUILDING CODES. Date: 7/17/2017 AppficatWmdlumher_•;:.:j, iBRES2017-0126 Owner: Property Address: 81115 GOLF VIEW DR DOUGLAS SABELLA APN: 762280011 Application Description: SABELA / 245SF PATIO CONVERSION TO DINING.ROOM 92253 Property Zoning: Application Valuation: $37,500.00 Applicant: Contractor: LANG CONSTRUCTION LANG CONSTRUCTION 80590 CAMINO SAN GREGORIO 80590 CAMINO SAN GREGORIO INDIO, CA 92203 INDIO, CA 92203 (760)702-7744 Llc. No.: 748605 -------------------------------------------------'-------------------------------------------- Detail: 245SF PATIO CONVERSION TO DINING ROOM [ENGINEERED) THIS PERMIT DOES NOT INCLUDE REPLACEMENT OF HVAC SYSTEMS, ALTERATIONS TO PLUMBING INSTALLATIONS OR REMODEL TO THE EXISTING DWELLING AREAS. 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • 'DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $65.36 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $179.36 Total Paid for ADDITION: $390.64 DESCRIPTION ACCOUNT QTY AMOUNT BSAS S81473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402. 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $38.00 Total Paid for MECHANICAL: $76.00 DESCRIPTION - ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $4.88 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $4.88 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin # City of La Qulnta Building &r Safety Division 78-495 Calle Tampico La Quinta, CA 92253.- (760).777-701.2 Building Permit Application and Tracking Sheet Permit # erojoec t Address: 1s View � towner sName: l &8CLL A. P. Number: �(D2 Zg�C7 m cel i5 VAddress: Legal Description: t Ccty, ST, Zip: Contractor: �� CUas vG7co � T .ele h one: _P ���• �: Address: ' 0,- S10 C��1 d� �r O v tity, ST, Zip: 'I� Li 10 2 (7 Te lehn .7 P o e.• P O tate Lic. # : rCity Lic. #.`.Ok45,71t P 5-je�Description:• SAI ITET of=.. pNJIIJ I r 1 Arch., Engr., Designer- esignerAddress: Address:a ?� , City, ST, Zip: Telephone: Construction s ction TY P e: Occupancy: State to Lic. # S Project tYFa (circle one): New Add'n Alter Repair Demo of Contact Person: go 5-�� Sq. Ft: #Stories: #Units: -game tj lbphone # of Contact Person: �7iOS Estimated.Value of Project. %j'j APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets a Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up' S.M.I. H.O.A.-Approval Plans resubmitted Grading IN HOUSE:- 3w Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees Coachella Valley Unified School District This'Box For District use only 83-733 Avenue 55, Thermal, CA . 92274 DEVELOPER FEES PAID: (760) 398-5909 — Fax (760):398-1224.• :.. y AREA: .. - AMOUNT LEVEL ONE AMOUNT: : .LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMWFND: AMOUNT: DATE:'' ... .. RECEIPT:' -" CHECK#: - .- ...INITIALS ..:CERTIFICATE OF COMPLIANCE ` (California Education Code 17620) .Project Name: PGA West •` ` Date: July 12, 2017. . Owner's Name: Douglas Sabella Phone No. Project Address: 81-115 Golf View Dr. Project Description: Dining Room Addition APN: 762-280-011 Tract #:, Lot #'s - Type of Development:. Residential XX! Commercial Industrial .. _ Total -Square - Feet of Building Area:.. 245 sq. ft:- Certification of Applicant/Owners:. The person signing certifies that the above information is correct and makes this statement under ' penalty of perjury and further represents that he/she ds authorized to sign on behalf of the tier/developer. Dated: _ July 12, 2017 Signature:...... SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) 'Education Code, Gov. Code:, Project: Agreement Existing Not Subject to Fee 17620 65995 '' Approval., Prior'to 1/1/87 Requirement Number of Sq.Ft. 245 ' 'Pursuant to AB 181 any room additions or enclosures of 500 Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's Amount Collected, $0.00 .....jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance • Certificate issued"by Laurie Howard, Secretary. • - Signature:(�����ac--c--t 1` `� v - NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of -the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. :As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will to J -)41 &&r good cause, as determined by the School District, and up to three (3) such extensions may be grarited.. RECD. M V:c/inydoes/devtees/certificate of compliance form updated 3 -?007. I l/2010 JUL:1 , 20.1.7 CITY OF LA QUINTA PLANNING DEPARTMENT Plan Submittal Job Site Owners N Number, Stmt, or PO City, State, Postal C Chimers Phone Nur Owners E -Mall Add Project Managers Project Managers Phone N Builder / Contrg Number, Street or PO City, State, Postal C Project Square Building Permit Number. ate FES Int 17d Project Description: new room adddon Exempt 10 (Materials may contain hazardous wastes and aro not subject to recycling provisions) Construction Debris Management Plan City Approval By Date of City Approval 7/12/2017 81115 Golf Vlew Dr Douglas Sabella 81115 Golf View Dr Le Quints, CA. 92253 WA Russell Melchor 780-574-8887 Alp mvode0nsTl7f nmall.ccm Materials To Be Discarded: Product Trash Asphalt Bdck/Block Cardboard Commingled Concrete Drywall Donated / Reuse" "Describe Items Lary Lang Construction 80590 Camino san Gregorio Indio, CA. 92201 Approx. 245 square feet Renado Gouldlock-DEC/Buntec Waste m7 habg Tons 1.00 Not recyclable 0.00 Recyclable Recyclable Recyclable Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Totals: Re Is Trash Projected Diversion: 1.9 1 1.0 1 1 65,2-8—O I understand it is the property owners responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. l hereby car* that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least W/o of the jobstte waste Is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the pmjact in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retalns legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If sett-hsuMg, all refuse material from this project site must be taken to an approved recycter or transfer Owner / Developer I Project Manager I Superintendanf Date B"ANALY818',REPORT UILDIN.Q.,, NER,GY,,.': BY, -Job.. Number: 00t4MUNITyA'QuINTA VEL6PmE1YT Lang/Sabella Date: 6/29/2017 The EnergyPr§,computer program has beenused to perform the calculations summarized in !his; compliance repoit:'This program 'hai'apkr6val; and is authorized by th6;Calif6mia: Energy Comrission for use with botWthe'Reside ntial and Nonresidential 2016 , Building Energy( Efficiency Standards. This program developed by EnergySoft Software — wwwen:ergysolt.'com. EESslo# PROJECT: Normae Thom@S kE 309271 SABELLA ADDITION :-;c 81-115Vk- 'Golf -,w.Dr La Quints, CA -.02253 Project Designer: LARRY W. LANG,'.P.,E. 80590 CaminoSain'Gregorio Indib, CA 92203. 760 - 834 - 9020 Report Prepared by: KAY THOMAS T&K-Engpe,.ering 30535 AVENOA-gUENA SUERTE,.- TEMECULA, CA 92591 Of�951 699'0436' �& Ar N-.� OF '1A. -WINTA , - `�,t TY,--. DEP T BUILDI Nli"i,Sx I.i/ b -ED. Pok -CONSTRUCTION JUL 05 .2017 BY, -Job.. Number: 00t4MUNITyA'QuINTA VEL6PmE1YT Lang/Sabella Date: 6/29/2017 The EnergyPr§,computer program has beenused to perform the calculations summarized in !his; compliance repoit:'This program 'hai'apkr6val; and is authorized by th6;Calif6mia: Energy Comrission for use with botWthe'Reside ntial and Nonresidential 2016 , Building Energy( Efficiency Standards. This program developed by EnergySoft Software — wwwen:ergysolt.'com. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation Description: Title 24 Analysis Input File Name: Sabella Add Rev NLT-KFC 6.29.17.ribdl6x CF1 R -PRF -01 Page 1 of 6 GENERALLINFORMATION ENERGY USE SUMMARY 01 Project Name SABELLA ADDITION 04 05 02 -Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) , 03 Project Location. 81-115 Golf View Dr Compliance Margin Percent Improvement 04 City La Quinta 05 Standards'Mersion Compliance 2017 • 06 , Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09. Software Version- EnerpPro 7.1 10 Building Type Single Family • 11 Front Orientation (deg/Cardinal)90 12 Project Scope Newly Constructed (Addition Alone) 13 Number of Dwelling Units 1 14 Total Cond. Floor Area'(ftZ) 245 15 Number of -Zones 1 16 Slab Area (ft2) 245 17 Number of Stories 1 18 Addition Cond. Floor Area 245 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 245 21 Glazing Percentage•(%) 1.40.0% ADDITION ALONE PROJECT ANALYSIS PARAMETERS 01 02 03 04 05 06 Existing Area (excl. new addition) ft2 Addition Area (excl. existing) ft2 TOTAL AREA Existing Bedrooms Addition Bedrooms Total Bedrooms 1044.47 245 1289.47 0 0 0 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS, -Verification 03 This building incorporates.one or more Special Features shown below Registration Number: CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: Report Version : CF1 R-05232017-695 HERS Provider: Report Generated'at: 2017-06-29 15:03:13 ENERGY USE SUMMARY 04 05 06 07- 08 Energy Use (kTDV/ft2-yr) , Standard Design Proposed Design, Compliance Margin Percent Improvement Space Heating. 0.58 1.28 -0.70. -.120.7% Space Cooling 163.20 '167.08 -3.8-8 -2.4% ` IAQ Ventilation 0.00 0:00 0.00 0.0% Water.Heating 35.82 30.91 4.91 13.7% Photovoltaic Offset — 0.00 0.00 Compliance Energy Total 199.60 199.27 0.33 0:2% Registration Number: CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: Report Version : CF1 R-05232017-695 HERS Provider: Report Generated'at: 2017-06-29 15:03:13 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project -Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation Description: Title 24 Analysis Input File Name:. Sabella Add Rev NLT KFC 6.29.17.ribdl6x CF1 R=PRF-01 Page 2 of 6 REQUIRED*. EQUIRED SPECIAL FEATURES The following are features that must be installed, as condition for meeting the modeled energy performance for this computer analysis. • Coohioof Insulation below roof deck • Window overhangs and/or fins • New ductwork added is less ' than. 40 ft. in length HERS FEATURE, SUMMARY The following is a summary of the features that must be.field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components.tables below. Building -level Verifications: • None—' Cooling System Verifications: • — None — HVAC Distribution System Verifications: • — None — Domestic Hot Water System Verifications: • — None — BUILDING - FEATURES INFORMATION 01 02 03 04' 05 06 07 Project Name Conditioned Floor,Area (ft2) Number of Dwelling. Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems SABELLA ADDITION 245 1 0 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type. HVAC System Name •Zone Floor Area . W) Ayg..Cbiling Height Water'Heating'System 1 Water Heating System 2 ENTIRE ZONE Conditioned Existing HVAC1' 245 12 DHW-Sys 1 OPAQUE SURFACES 01 02 03 _ 04 05 06� 07 08 ,, Name ;Zone Construction Azimuth*,' Crier'itation .Gross Area.(ft2) Window 8 Door Area (ftp) Tilt (deg) FRONT Wall ENTIRE ZONE R-30 Wall 90, Front ' 153 78 90 LEFT Wall ENTIRE`ZONE . R-30 Wall, 180 Left 229 20 90 . BACK Wall, ENTIRE ZONE R -M, Wall 270. Back 153 0 90, RIGHT Wall ENTIRE ZONE R-30 Wall 0 Right 229 0 90 Roof ENTIRE ZONE R-38 + R-38 Sheathing 245 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 HERS Provider. Report Generated at: 2017-06-29 15:03:13 CERTIFICATE OF COMPLIANCE - RESIDENTIAL. PERFORMANCE COMPLIANCE METHOD. Project Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation Description: Title 24 Analysis Input File Name: Sabella Add Rev NLT-KFC 6.29.17.ribdl6x CF1 R -PRF -01 Page 3 of 6 ATTIC 01 02 03 04 05 06 07 08 Name. Construction Type Roof Rise Roof Reflectance Roof Emittarice Radiant Barrier Cool Roof Attic ENTIRE ZONE Attic RoofENTIRE ZONE Ventilated 5 0.2 0.75. Yes Yes FENESTRATION I GLAZIN'G' 01 02 0 04 05 06 07 .08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height- (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading Sliding Glass Door Window FRONT Wall, (Front -90) 10.0 10.0 0.78 78.0 0.30 0.23 Insect Screen (default) Left Windows Window LEFT Wall (Left -180) — -- 1 1 20.0 0.30 1 0.23 Insect Screen (default) OVERHANGS AND FINS 01 02 01 02 03 04_ 05 06 07 08. 09 10 11. 12 13. 14 Overhang Left Fin Right Fin. Window Depth Dist Up Left Extent Right Extent TFIap Ht Depth Top Up ., DistL Bot Up Depth Top. Up Dist R Bot Up Sliding Gla,ssboor 12 0.1 .5 19 1 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Under Roof Joists: R-25.0 insul • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck., Wood Siding/sheathing/decking Attic RoofENTIRE ZONE Attic Roofs . Wood Framed Ceiling in. O.C. R 38 0.026 Roofing.*. 10 PSF (RoofTile) • Inside Finish: Gypsum Board Cavity/Frame: R -30/2x6 14-30 Wall Exterior Walls Wood Framed Wail 2x6 @ 16 in. O.C. R 30 0.059 Exterior Finish: 3 Coat Stucco •" Inside"Finish: Gypsum Board Ceilings (below Cavity/Frame: R=9:1 /2x4 R-38 + R-38 Sheathing . attic) Wood. Framed Ceiling" 2x4 @ 16 in. O.C. R 38 0.025 Over, Ceiling Joists: R-28:9 insuL SLAB FLOORS 01 02 03' 04 'OS 06 07 Name Zone Area (ft2) Perimeter(ft) Edge lnsul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade ENTIRE ZONE 245 64 None 0.8 No Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-29 15:03:13 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation Description: Title 24 Analysis Input File Name: Sabella Add Rev NLT-KFC 6.29.17.ribd16x BUILDING ENVELOPE -HERS VERIFICATION 01 02 03 04 QualityInsulation.lnsallation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air' Leakage CFM50 Not Required Not Required Not Required - CF1 R -PRF -01 Page 4 of 6 WATER HEATING SYSTEMS 01 02 03 04 - 05 06 Name System Type Distribution. Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Distribution Name Existing HVAC1 Other Heating and Cooling System Heating Component 1 Tank Energy Air Distribution System 1 Tank Insulation Tank Location or Heater Number Volume Factor or Input R -value Standby Loss I Ambient Name Element Type Tank Type of Units .(gal) Efficiency Rating/Pilot (Int/Ext) Recovery Eff NEEA Heat Pump Type Condition DHW Heater 1 Gas instan anleous 1 0 0.95 EF 190,000 Btu/hr R-0 n/a' n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Existing HVAC1 Other Heating and Cooling System Heating Component 1 Cooling Component.1 HVAC,Fan.1 Air Distribution System 1 HVAC'- HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntriFurnace 1 95 AFUE HVAC. COOLING UNIT TYPES 01 02 03 64 05 06 07 08 Name, System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 NoCooling Registration Number: Registration DateMme: HERS Provider: CA.Building Energy Efficiency Standards - 2016 Residential Compliance Report Version = CF1 R-05232017-695 Report Generated*at: 2017-06-29 15:03:13 CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation'De'scription. Title 24 Analysis Input FileName: Sabella:Add Rev NLT-KFC 6.29.17.ribdl6x CF1 R' -PRF -01 - Page'S,of 6 - HVAC - DISTRIBUTION SYSTEMS' , 02 , 03 04 05 `, 06'_' 06.: _ Name Type Duct Leakage ,Insulation R -value Duct Location Bypass DUct HERS Verification Air.Distnbubon System 1 DuctsAttic Sealed and tested 6 :Attic None Air Distribution System ;" rs di . HVAC°DISTRIBUTION -HERS VERIFICATION , 01 02' 03,- "04 .05 06.: _ OZ 08 Name : Duct Leakage Verification DuctsLeakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts • Deeply,Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Not Required -Not Required Not Required Not'Required Not Required HVAC - FAN SYSTEMS 01 02 03 04 Name Type 'Fan Power,(Watts/CFM) HERS Verification HVAC Fan 1 Single.Speed PSG Furnace Fane 0:58 — r RegistrationsNurfiber: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards -.2016 Residential Compliance Report Version on, CF1 R-05232017-695 Report' Generated at: 2017-06-29 15:03:13 CERTIFICATE -OF COMPLIANCE.- RESIDENTIAL PERFORMANCE • COMPLIANCE'METHOD Project Name: SABELLA ADDITION Calculation Date/Time: 15:03, Thu, Jun 29, 2017 Calculation Description:: Title 24`Analysis Input File�Name:-,Sabella Add Rev NLT KFC 6.29.17.ribd16x, CF1 R -PRF -01 Page 6 of 6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT certifythat this Certificate of Compliance'documentation is accurate,and.complete. - Documeritation Author Name: '" Do'currientation Author Signatur;i- n� 1;A : TFH1: )AV- kS Company: Signature Date: F&I : En€lint erino 3/2!:)1:11 17. Address CEA/HERS Cerfifcation Identification (If applicable): ::;Of 35A',PE-41D.,A 131 1ENIA "E1; IEF;',..• City/State/7ip: Ikl 1ECULi ; CA 591 Phone: !:)f: 1 699.-0- 36 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. l certify'that the energy features and perforrimance specifications identified on this Certificate of Compliance conform to -the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building'designfeatures or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations; plans and'specifications submitted to the enforcement agency for approval with this.building permit application.ccin " Responsible Desi . ner Name: �, r Y( f CE ^ ::I, NC ?M-TMAE Responsible Designer Signature: Q�� F,c •. i® 'fA-, , .17,tph Company: l.:Al :RY V'J: ASIC i, E. Date.Signed: 6:29.17 y Norm 30g2� ROE . 31311?a Address: i.Of 30 Carr no Sm 3rE, ;►` License:. C1,����� �j4TE:'OF. Cp���` City/State/Zip: 1 -<id �, Ck. 9 20<a Phone: 'r:.) - 8 4 90:!!,(, Registration Date/Time: Report"Version-.CF1.R-05232017-695, HERS. Provider: " Report, Generated. at: 2017-06-29 15:03:13 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name SABELLA ADDITION Building Type m Single Family m Addition Alone ❑.Multi Family ❑ Existing+Addition/Alteration" Date 6/29/2017 Project Address 81-115 Golf View Dr La Quinta California Energy Climate Zone CA Climate Zone 15 I Total Cond. Floor Area 245 Addition 245 # of Units 1 INSULATION Construction Ty pe Area " Cavi Ijft) Special Features Status Wall Wood Framed R 30 666 New ' Roof Wood Framed Attic R 38 245 Add=R-38:0 Cool Roof & Radiant Barrier Existing, Slab Unheated Slab-on-Grade - no insulation 245 Perim = 64' New FENESTRATION Total Area: -981 Glazing Percentage: 40.0 %1 New/Altered Avera a U-Factor. 0.30 Orientation 'Area(ft), 'U-Fac SHGC Overhang Sidefins Exterior Shades Status Front (E) 78.0 0.300 0.23. 12.0 none Bug Screen New Left (S) 20.0 0.300 0.23 none none Bug Screen New HVAC SYSTEMS Q " . Heatino Min. Eff Cooling Min..Eff Thermostat Status 1 Cential Furnace. 95% AFUE No Cooling 14.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R=Value Status Existing HVAC Ducted Ducted Attic" 6.0 New, WATER HEATING Qty-. Type Gallons Min. Eff Distribution Status NAP Existing �—En—e,gyPm I 7.1 by EnemySoft User Number. 3089 ID: Lan Sabella Pa ge 8. of 13 2016 Low -Rise Residential Mandatory 'Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for mon; information. 'Exceptions may apply. (Original 08/2016) Building Envelope Measures: - § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011 § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstrid.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § .110.8(g). § 110.8(1): Roofing Products Solar Reflectance and Thermal Emiftance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 i .when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U4actor must not exceed 0.043. Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation.Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0002 or less (R-19 in 2x6 or U -factor of 0.074 or § 150.0(c): less). Opaque nori-framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without' facings, no greater than 0.3%; have a water vapor. permeance no greater than 2.0 permAnch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8 § 150.0(8)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applieito controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on.the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum Ll factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58 Fireplaces; Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least SiXr square inches in area and is equipped with a readily accessible, operable, and fight -fitting damper or combustion -air control device' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating,:and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for com ression heating is higher than the cut-off temperature for su lementa • heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUmr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.= § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an.electrical supply voltage connection with pilot lig hts that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Re sidential,MandatoryAeasures Summary § 150:0(h)3A: Clearances. Installed air conditioner -and heat pump.outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturers instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling'system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)26: Water "piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water"piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution . piping for steam and h dronic heatin systems or hot waters stems must meet therequirements in TABLE 120.3-A.* § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight; moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with.a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum; sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)38: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l': 120V electrical receptacle within 3 feet of the water heater, a Category III or IV vent, or a Type,6 vent with straight'pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural drainingwithout pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops.. Recirculating loops serving multiple dwelling units must meet the -requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0,of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air-0istribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0,602:0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions' of supply -air and retum-air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l : (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '% inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements s ecified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)& Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air o enin s and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing; in accordance with § 150.0 m l land Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to_have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)l: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar healing. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.- § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)l B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for. insulation contact (IC) § 150.0(k)l C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)l C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)l D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)l E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)l F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)l G: with Reference Joint Appendix JA8. Installed lamps must be marked with 'JA8-2016° or 'JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)l H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with 'JA8-2016-E.' § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5ft and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(0; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9,130.0,130.2,130.4,140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9,130.0,130.1,130.4,140.6, and 141.0. Interior Common Areas of Low-rise Mufti -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0,130.1. 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Titie 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipmenC Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as 'For Future Solar Electric". A HVAC. SYSTEM MEATING AND COOLING LOADS SUMMARY - ' Project Name Date SABEL'LA ADDITION. 6/29/2017 System NameFloor Area Existing: HVAG 245 ENGINEERING CHECKS SYSTEM LOAD ` Number of S stems 1 COIL CFM Total Room Loads 192 Return Vented Lighting -Return Air Ducts Return Fan Ventilation 4 Supply Fan Supply Air. Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM I 4;497 267 142 0 307 0 149. 87 4 0 307 5,260 354 PEAK. *Heating System Sensible Output per,System, 10,000 .5,461 Total Output (Btuh 10;000 Output Btuhls ft 40.8 315 Coolin :S stem 0 Out ut". er System 0 185 Total Output (Btuh• 0 ''0 Total Ou ut Tons 0.0 315 Total "Ou - ut Btuhis ft 0.0 Total Output s ftfTon U:0 6,277 Air S stem' . CFM perS stem . 300 ::HVAC EQUIPMENT SELECTION z �' Airflow cfm 300 EXISTING FURNACE `' 0, 0 10,000 Airflow cfm/s 1.22, Airflow cfm/Ton) 0.0 ? Outside Air % 1.49/6 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0 0 Aug PM 10,000 Jan 1 AM Outside Air cfmis `ft 0.02 Note values above iven.at ARl'conditions -HEATING SYSTEM PSYCHROMETRICS:(Airstream 'Temperatures at Time of.Heatin Peak Outside Air 4 cfrn Heating Coil Supply Fan 300 drn ROOM 67 OF 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin .Peak 79 / 63 OF 55154 OF 55 / 54 OF Outside Air I� 4 cfm Cooling Coil Supply Fan 56 / 54 OF 300 cfm-- 42.0 °i° F ROOM EnergyPro 7. 1. by EnergySoft User Number. 3089 ID; Eang/Sabella Page 13. of 13'