Loading...
BRES2014-114978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 9225) Application Number: BRES2014-1149 Property Address: 79370 CANTERBURY APN: 775032004 Application Description: 452 S.F. CASITA Property Zoning: Application Valuation: $50,000.00 Applicant: DENNIS R INGRAM 1216E MAIN ST MEDFORD, OR 97504 .C& Q D 4v VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153: BUILDING PERMIT Date: 1/15/2015 Owner: DENNIS R INGRAM 1216E MAIN ST MEDFORD, OR 9-504 JAN 15 2015 CITY OF LA OUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 985547 Date-- 1 ! Contractor: 01 -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter; improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Contractor: PINNACLE CUSTOM BUILDERS 45614 CIMARRAON ROAD INDIO, CA 92201 (760)989-5435 Lic. No.: 985547 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one ofi the following declarations: V(j'ffiave and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance o1 the work for which this permit is issued. _ I have and will maintain workers' cornpensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:. Carrier: _ Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so 3s to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMIMAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOt IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNCWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this appli=:ation is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and :he applicant, each agrees to, and shall defend; indemnify and hold harmless the City 4 La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such'permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned roperty fo/r inspection purposes. Date: S Signature (Applicant x Agen ) DESCRIPTION FINANCIAL • . ACCOUNT - QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $62.36 $62.36 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT, - PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.40 $17.40 1/15/15 PAID BY _METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.83 $120.83 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION • ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $171.14 $171.14 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH Total Paid forADDITION: $371.73 $371.73 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK - YES 101-0000-42600 1.5 $105.00 $105.00 1/15/15 PAID BY METHOD -RECEIPT # = CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH- Total Paid forBLDG CITY STAFF - PER HOUR: $105.00 $105.00 DESCRIPTION ACCOUNT + QTY AMOUNT = PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $2.00 $2.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $145.03 $145.03 1/15/15 PAID BY METHOD RECEIPT # = CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.86 $47:86 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH- Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $36.26 $36.26 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH P DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $24.17 $24.17 1/15/15 -PAID BY r = METHOD RECEIPT # CHECK # CLTD BY ' DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $36.26 $36.26 1/15/is PAID BY METHOD RECEIPT'# a` CHECK # `CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT:, QTY :. AMOUNT, 'PAID PAID DATE FURNACE PC 101-0000-42600 0 $24.17 $24.17 1/15/15 . PAID BY'.. :METHOD.. _' RECEIPT#.-< " CHECK #=CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION 'ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $36.27 $36.27 1/15/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION'ACCOUNT QTY AMOUNT i PAID . PAID DATE VENT FAN PC 101-0000-42600 0 $14.49 $14.49 1/15/15. Y PAID BY METHOD RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH- Total Paid forMECHANICAL: $171.62 $171.62 4 DESCRIPTION ACCOUNT- QTY AMOUNT PAID- . PAID DATE FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 1/15/15 PAID BY. METHOD , r RECEIPT #CHECK # ',;" "` CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ,ACCOUNT QTY AMOUNT PAID, PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 1/15/15 PAID BY , METHOD RECEIPT # = CHECK# CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID'DATE GAS SYSTEM, 1 -4 -OUTLETS 101-0000-42401 0 $12.09 $12.09 1/15/15 PAID BY METHOD RECEIPT #`4 CHECK # CLTD BY' DENNIS R. INGRAM CHECK R3420 6164 SKH DESCRIPTION ACCOUNT QTY AMOUNT s PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $24.17 $24.17 1/15/15 PAID BY METHOD" RECEIPT # CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH _ DESCRIPTION "ACCOUNT QTY AMOUNT ;PAID •' PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12:09 $12:09 1/15/15 " PAID'BY ', M METHOD: RECEIPT # CHECK #' CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH. DESCRIPTIONACCOUNT QTY. AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $7.25 1/15/15 PAID BY p :x . '. METHOD; " l ,. >r , .RECEIPT #, ? 1, CHECK # CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH Total Paid for PLUMBING FEES: $152.32 $152.32 ` ,DESCRIPTION �. Q xACCOUNT ` QTY AMOUNT �` -PAID . PAID DATE SMI -RESIDENTIAL 101-0000-20308 0 $6.50 $6.50 1/15/15 * , ' PAID BY METHOD G RECEIPT # CHECK # °;'' CLTD BY DENNIS R. INGRAM CHECK R3420 6164 SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $6.50 $6.50 TOTALS: $1,002.06 $1,002.06 ' t ' j n• • i` 7� ` t • e _ z ' t ' j Description: 452 S.F. CASITA ADDITIONAL Type: BUILDING, RESIDENTIAL Subtype: ADDITION Status: ISSUED Applied: 10/24/2014 KHE Approved: 1/15/2015 AZA Parcel No: 775032004 Site Address: 79370 CANTERBURY LA QUINTA,CA 92253 Subdivision: TR 24317-1 Block: Lot: 3 Issued: 1/15/2015 AZA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $50,000.00 Occupancy Type: Construction Type: Expired: 7/14/2015 AZA No. Buildings: 0 No. Stories: 0 No. Unites: 0 12/22/2014 Details: 450 SQ. FT. DETACHED CASITA PER 2013 CRC CODES. RECEIVED 83 1Applied to Approved Approved to Issued Printed: Thursday, January 15, 2015 5:46:12 PM 1 of 5 Q...._L7CT......._ _ ADDITIONAL CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE ANGELICA ZARCO 1/15/2015 1/15/2015 RESIDENTIAL READY TO ISSUE CHECKLIST SHOWS THAT ALL ITEMS HAVE SATISFIED. APPROVING AND ISSUING PERMIT. PLAN CHECK COMMENTS FROM CONSULTANT ARMEN ALTOUNIAN 12/18/2014 12/22/2014 PLANS APPROVED FROM YOUNG. RECEIVED PLAN CHECK COMMENTS FRnm rnNSI11TONT KAY HENSEL 11/7/2014 11/7/1014 6TRUC RFC 11/6/14 RECEIVED PLAN CHECK PICKED UP MARY FASANO 11/12/2014 11/12/2014 PLAN CHECK SUBMITTAL KAY HENSEL 10/24/2014 10/24/2014 RECEIVED RESUBMITTAL STEPHANIE KHATAMI 12/15/2014 12/15/2014 Printed: Thursday, January 15, 2015 5:46:12 PM 1 of 5 Q...._L7CT......._ _ SENT TO PLAN CHECK KAY HENSEL 10/24/2014 FINANCIAL • 10/24/2014 STRUC TO YOUNG, DUE 11/6/14 CONSULTANT SENT TO PLAN CHECK KAY HENSEL• 12/15/2014 12/15/2014 STRUC TO YOUNG - HOPEFULLY, A QUICK PC - DUE 12/23/14 CONSULTANT CLTD DESCRIP,TIOW, : ' ACCOUNT QTY AMOUNT, ; ' PAID TELEPHONE CALL ARMEN ALTOUNIAN 12/22/2014 CHECK # METHOD 12/22/2014 PLANS APPROVED AND READY. FOR PICK UP PENDING STRUCTURAL CHANGE NOTED. TELEPHONE CALL JIM JOHNSON 11/7/2014 ADDITION, EA 101-6000=42400 0 11/7/2014 $62.36 CALLED EDWARDO NAVA @777-3260 TO PICK UP R3420 6164 CHECK DENNIS R. INGRAM SKH ADDITIONAL 500 SF CORRECTIONS ""'""'"""'CONDITIONS • 101-0000-42600 0 $17.40 $17.40 NAME TYPE °' '.?NAME- y'�.F ` ADDRESSIS gym= "CITYn .•STATE', . ZIP., PHONE"FAX, rf5¢, ADDITIONAL 5000 SF PC APPLICANT DENNIS R INGRAM 1216 E MAIN ST MEDFORD OR 97504 (760)989-5435 ADDITION, FIRST 100 SF CONTRACTOR PINNACLE CUSTOM BUILDERS 45614 CIMARRAON INDIO CA 92201 (760)989-5435 6164 CHECK ROAD SKH ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 OWNER DENNIS R INGRAM 1216 E MAIN ST I MEDFORD I OR 1 97504 1 (760)989-5435 DENNIS R. INGRAM Printed: Thursday, January 15, 2015 5:46:12 PM 2 of 5 FINANCIAL • • CLTD DESCRIP,TIOW, : ' ACCOUNT QTY AMOUNT, ; ' PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY ADDITION, EA 101-6000=42400 0 $62.36 $62.36 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH ADDITIONAL 500 SF ' ADDITION, 101-0000-42600 0 $17.40 $17.40 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH ADDITIONAL 5000 SF PC ADDITION, FIRST 100 SF .101-0000-42400 0 $120.83 $120.83 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH ADDITION, FIRST 100 SF 101-0000-42600 0 $171.14 $171.14 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH PC Total Paid forADDITION: $371.73 $371.73 HOURLY PLAN CHECK - 101-0000-42600 1.5 $105.00 $105.00 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH YES Total Paid for BLDG CITY STAFF - PER HOUR: $105.00 $105.00 Printed: Thursday, January 15, 2015 5:46:12 PM 2 of 5 cFM:•Oe,Tt�t DESCRIPTION p ,., ,ACCOUNT QTY AMOUNT PAID PAID DATE' •RECEIPT W #- ° METHOD PAID BY CLTD' .CHECK 'B BSAS SB1473 FEE .101-0000-20306. 0 $2.00 $2.00 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH Total Paid forBUILDING STANDARDS ADMINISTRATION $2,00 $2.00 BSA: RESIDENTIAL, FIRST 101-0000-42403 0 $145.03 $145.03 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH 1,000SF RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH 1,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89 CONDENSER/COMPRES 101-0000-42402 0 $36.26 $36.26 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH SOR CONDENSER/COMPRES 101-0000-42600 0 $24.17 $24.17 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH SOR PC FURNACE 101-0000-42402 0 $36.26 $36.26 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH FURNACE PC 101-0000-42600 0 • $24.17 $24.17 1/15/15 R3420• 6164 CHECK ' DENNIS R. INGRAM SKH VENT FAN 101-0000-42402 0 $36.27 $36.27 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH VENT FAN PC 101-0000-42600 0 $14.49 $14.49 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH Total Paid forMECHANICAL: $171.62 $171.62 FIXTURE/TRAP 101-0000-42401 0 $48.36 $48.36 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH FIXTURE/TRAP PC 101-0000-42600 0 $48.36 $48.36 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH GAS SYSTEM, 1-4 101-0000-42401 0 $12.09 $12.09 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH OUTLETS GAS SYSTEM, 1-4 101-0000-42600 0 $24.17 $24.17 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH OUTLETS PC WATER HEATER/VENT 101-0000-42401 0 .$12.09. $12.09 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH Printed: Thursday, January 15, 2015 5:46:12 PM 3 of 5 - ,..,,.BOND INFORMATION Printed: Thursday, January 15, 2015 5:46:12 PM 4 of 5 PARENT PROJECTS J REVIEUV � ..}t. .. `DUE RETURNED : `� STATUS. Y� REMARKS CLTD DESCRIPTION ACCOUNT QTY. AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY ARMEN 10/24/2014 11/6/2014 10/28/2014 BY WATER HEATER/VENT NON-STRUCTURAL RFC ALTOUNIAN 101-0000-42600 0 $7.25 $7.25 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH PC REVISIONS REQUIRED CORRECTIONS 1ST. STRUC PLAN CHECK READY FOR Total Paid for PLUMBING FEES: $152.32 $152.32 SMI - RESIDENTIAL 101-0000-20308 0 $6.50 $6.50 1/15/15 R3420 6164 CHECK DENNIS R. INGRAM SKH Total Paid forSTRONG MOTION INSTRUMENTATION SMI $6.50 $6.50 ,..,,.BOND INFORMATION Printed: Thursday, January 15, 2015 5:46:12 PM 4 of 5 PARENT PROJECTS J REVIEUV � ..}t. .. `DUE RETURNED : `� STATUS. Y� REMARKS TYPE:; y REVIEWER s z� SENT,DATE DATE D. ` LL NOTESr ARMEN 10/24/2014 11/6/2014 10/28/2014 REVISIONS REQUIRED 1ST REVIEW NON-STRUCTURAL RFC ALTOUNIAN STRUCTURAL JIM JOHNSON 10/24/2014 11/6/2014 11/7/2014 REVISIONS REQUIRED CORRECTIONS 1ST. STRUC PLAN CHECK READY FOR CORRECTIONS ARMEN 12/15/2014 12/23/2014 12/22/2014 APPROVED 2ND PLAN CHECK NON-STRUCTURAL APPROVED ALTOUNIAN STRUC TO YOUNG, DUE 12/23/15. - STRUCTURAL KATHRYN 12/15/2014 12/23/2014 12/22/2014 APPROVED 2ND PLAN CHECK APPROVED PENDING STRUCTURAL ENGINEER SAMUELS W/CONDITIONS REVISE SHEAR WALL "E" TO TYPE 2 PER THE STRUCTURAL CALCULATIONS ,..,,.BOND INFORMATION Printed: Thursday, January 15, 2015 5:46:12 PM 4 of 5 C' S Printed: Thursday, January 15, 2015 5:46:12 PM 5 of 5 _._.._ Bin # �7I - ' �y of La Quini Qty Building 8r Safety Division y - Permit #..� �, l� ''� P.O. Box 1504, 78 495 Calle Tampico La Quinta, CA'92253'- (760).777-7012 Building Permit Application and Tracking Sheet' Project Address: # • X9.3 D Owner's Name: A. P. Number: Address: '„ 7- • Legal Description: s e Ci ST Zi �' ' p: t D a D27501/ Contractor: ' S o �.. �'ss,E>>�> �^'r'<"�><><•:: Tele= h nc: Address: Project Description: 1. City, ST, Zip: t Ca S /- C/} 0!%l - Tele hone• P State Lic. # . City Lie. #.: r.. Arch., Engr., Designer. Address: • ,, ' City, ST, Zip: Telephone: e: OecuP an cY �Con mct, iTY�P v►� Fr Pr Ject t5'Pe cir ] one):' � New Add'n Alter Repair Dem o State Li. #c Name of Contact Person: �V pa D v t� Sq. Ft.:zo # Stories: � # Units: Telephone #,of Contact Person: '� 6 '� •'� Estimated Value of Project: �3 � p 00 APPLICANT: DO NOT WRITE BELOW THIS LINE' # Submittal Req'd Recd TRA CiCITIG ` , Ai, PERMIT FEES Plan Sets „J Plan Check submitted p� Item Amount' Structural Calcs. I �' : Reviewed, ready or corrections 7 Plan Check Deposit Trusi Calcs. Called Contact Pc o Plan Check Balance, Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted � Mechanical Grading plan t 2°" Review, ready for correction issue Electrical Subcontactor List Called Contact Person �Z Plumbing Grant Deed • Plans picked up a S.M.I. Ii.O.A. Approval Pians resubmitted Grading Developer Impact Fee rN HOUSE:= '`" Review, ready for correctio issue Planning Approval Called Contact Person 1 A.I.P.P. Pub. Wks. Appr - Date of permit issue School Fees ' Total Permit Fees /Oz 15 1 z1,- Nle �%Y'Pbe CERTIFICATE OF COMPLIANCE C" Desert Sands Unified School District Z4eeRnnuoAouor 47950 Dune Palms Road V) RANCHO MIRAGE Date 11/13/14 La Quinta, CA 92253 S,�' INOIANWELLS NO.. 31621 �c� P LAQUINTA� y (760) 771-8515 ��QINDIO y7� p Owner Ingram APN # 775-032-004 Address 79-730 Canterbury Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Detached Guest House Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79730 Canterbury 450 Unit 6 Unit 2 Unit ? Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments - At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.36 X 450 S.F. or $1,512.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC -Chase - Dennis Ingram . Check No. 1038919988 Bank Name/Recipient of Certificate. Telephone Funding Residential BY Dr. Gary Rutherford Superintendent r� Fee collected /exem Sh o C ilvrey Payment Recd $0.00 $1,512.00 "Over/Under- Signature NOTICE: Pursuant to Government Code Sec ' 66020(d)(1), this ill s rve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on ' h the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant. Copy - Applicant/Receipt Copy- Accounting . L� Building Permit Number. oa �.. Project Description: SFR Exempt 0 «+� (Materials may contain hazardous wastes and e not $ubject to recycling provtskNU) of Construction Debris Management Pian Prem Submittal Deb 119/2015 Job Bile Address 79370 CenDerbury owners Name Dennis Ingram Number, Street, or PO Box Owners E-MaA Address Trash Protea Manegerd fame Jerry Perez Pn4ed Managers Phone Number 760-702-9222 Project Markers E-mallAddress 7 Bukder / Contractorl Hugo Aceves dbe Pinnacle Custom Builders Number.Sft9torP0s*xJLL4W14CImaffonRd City, State, Postal Code Indio, CA. 92201 Project Square Footage Approx 452 sq ft City Approval By Date of City Approval O 1 /dq /is; Materials To Be Discarded: Product. L Tons Trash 2.50 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable BrICkJBlock 0.00 Recyclable Plaster 0.25 Recyclable Cardboard 0.00 Recydebte ; Scrap Metal 0.00 Revydable Commingled L 0.00 Reelable file (floor) 0.00 Recyclable Concrete 225 Recyclable, -Tile (roof) 0.12 Ra yciable DMNaII 0.25 Recydabte Wood 0.50 Recyclable Donated / Reuse• 0.00 Recyclable" Landscape Debris 0.00 Recyclable 'Describe Items Totals: Recycle Trash 3.4 2.5 1 understand it fs the property Owner's, responsibility I submit co1111 of welght tickets or receipts to the Diswct Environmental coordinator as these haul ocwr. I hereby car* that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsits waste Is diverted from landfilling. The remaining material will be recycled or reused, I will divert, for recording or reuse, remaining materials generated from the first day of the project through the compktbn of the project in accordance with this plan. This DMP is issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may, obtain a DMP for the owner. However, the DMP is still issued In the name of the property owner(s) and the owner retains legal rosponsibEly for ensuring that the provisions of the DMP are adhered to. The property owners) and general contractor shall be kept informed of the diversion progress through bNrronthy reports: H setl-b8u8ng, all refuse material from this project eke must be taken to an approved recycler or transfer Owner /Developer / Project Mensger / Supetirntendant D— r;N ICC -ES Evaluation Report ESR -1761' Reissued December 1, 2013 This report is subject to renewal February 1, 2015. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 62 00—Unit Skylights REPORT HOLDER: ELITE SOLAR SYSTEMS, INC. 310 EAST COMSTOCK DRIVE CHANDLER, ARIZONA 85225 (480) 635-9748 www.elitesolarsystems.com lou(&elitesolarsystems.com EVALUATION SUBJECT: ELITE SOLAR SYSTEMS TUBULAR SKYLIGHTS 1.0 EVALUATION SCOPE Compliance with the following codes:. ' ■ 2006 International Building Code® (IBC) ■ 2006 International Residential Code® (IRC) ■ 1997 Uniform Building Code TM (UBC) Properties evaluated: ■ Structural ■ Water resistance ■ Durability , 2.0 USES The Elite Solar Systems Tubular Skylights described in this report are plastic glazed skylights that comply with Sections 2405 and 2610 of the IBC, Section R308.6 of the IRC, and Sections 2409 and 2603 of the UBC. 3.0 DESCRIPTION The Elite Solar Systems Tubular Skylights are produced in 10-, 13-, 18-, 21- and 24 -inch nominal diameters (part numbers 10ETS, 13ETS, 18ETS, 21ETS, 24ETS, respectively). The components include a dome, dome ring, aluminum self -flashing curb, reflective light tube, ceiling trim ring, light diffuser, and decorative ring. The domes are made of 0.220 -inch -thick (5.59 mm) acrylic plastic. The acrylic plastic is Plaskolite, Inc., Duraplex, which has a CC2 classification and is recognized in evaluation report ESR -2590. The light tubes are from 1 to 20 feet (305 to 6096 mm) long. At the ceiling level, an aluminum ring accepts the light tube. The light diffuser consists of either two or three lenses, with one or two lenses being 0.06 inch (1.524 mm) thick and one lens being 0.125 inch thick (3.175 mm). The lenses, made of acrylic plastic, recognized in ESR -2728, terminate the lower end of the 'light tube and are held in place with a powder -coated .aluminum ring. 4.0 INSTALLATION 4.1 General: Elite Solar Systems Tubular Skylights are packaged in shipping cartons for field installation. The cartons contain instructions, components, and attachments, including templates for roof and ceiling holes. During the installation, framing members must not be cut. Installation for various roof conditions includes the following: • On sloped roofs in accordance with Section 2610.3 of the IBC or Section 2603.7.1 of the UBC, the hole for the skylight must be 141/2, 181/2, or 22 inches (368, 470 or 559 mm) in diameter, corresponding, respectively, to the 10-, 13- and 18 -inch -diameter skylights. (The 21- and 24 -inch -diameter skylights are not used on sloped roofs.) On sloped roofs with existing roof covering, a 4 -inch (102 mm) slit is made parallel to the ridge. Nails and staples are cut underneath the underlayment toward the ridge, flashing is slid under the shingles, and the underlayment is centered with the hole. • On low sloped roofs (2:12), the hole for the skylight must be 11, 14, 19, 22 or 25 inches (279, 356, 483, 559, or 635 mm) in diameter, corresponding, respectively, to the 10-, 13-, 18-, 21- and 24 -inch -diameter skylights. With the bottom side of the flashing over roof tiles or shingles [on low sloped roofs, two or more 1/2 -inch - diameter (12 mm) concentric beads of supplied caulking are applied on the underside of the flashing], the base of the skylight is attached to the roof sheathing. For 10-, 13- and 18 -inch -diameter skylights, attachment is with fourteen No. 8 by 2 -inch -long (50.8 mm), self -drilling, stainless steel screws. For 21- and 24 -inch -diameter skylights, attachment is with sixteen of the same type of screw. The exposed screw heads must be caulked and the loose shingles secured. The dust seal provided is applied to the inside top part of the flashing. On the ceiling level, a 101/2-, 131/2-, 181/2-, 211/2-, or 241/2 -inch -diameter (267, 343, 470, 546, or 622 mm) hole is cut into the ceiling board for, respectively, the 10-, 13-, 18-, 21-, and 24 -inch - diameter units. The trim ring is secured to the ceiling board with three or four No. 8 by 11/2 -inch -long (38 mm) sheet metal screws installed in the flat nuts. The length of the light tube must be determined by measuring from the top of the base flashing to the bottom side of the trim ring. The light tube must be flush to the trim ring and fastened with three No. 8 by 1/2 -inch -long (13 mm), self -drilling, stainless steel screws. The light tube may be trimmed using tin snips /CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed Fam as an endorsement of the subject of the report or a recommendation for its rise. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to anyftnding or other matter in this report, or as to any product covered by the report. Copyright© 2013 Page 1 of 3 c7 F�)R-1761 I Most Widely Accepted and Trusted Page 2 of 3 and must be installed flush with the top of the 0.060 -inch- specified in, those codes listed in Section 1.0 of this report, thick (1.58 mm) aluminum flashing, which provides support subject to the following conditions: for the dome. 5.1 Installation must be in accordance with the The 10-, 13-, and 18 -inch -diameter domes are attached manufacturer's published installation instructions, this to thevertical section of the self -flashing curb with four report, and Sections 2405 and 2610.3, of the IBC, No. 8 by /8 -inch -long (9.5 mm), self -drilling, stainless steel Sectio Section 308.6 of the IRC, or Sections 2409 and d screws. The 21- and 24 -inch -diameter domes are attached .1 of the UBC, as applicable. In the event to the curb with six of the same type of screw. Gaps in roof conflict between this report and the manufacturer's shingles and around the base flashing must be sealed with published installation instructions, this report governs. the caulking materials provided. A decorative ring with a 5.2 The maximum positive and negative loads are as light diffuser is installed on the ceiling by aligning standoffs noted in Section 4.3 of this report. with the keyholes, and twisting to ft. 5.3 The use of the skylights as components of fire - 4.2 Concrete Tile Roof: resistance -rated assemblies is outside the scope of Holes must be made in the roof deck following procedures, this report. as described in Section .4.1. Several roof tiles are 5.4 The skylights are produced in Chandler, Arizona, removed around and beyond the opening, and must be under a quality control program with inspections by reinstalled after the skylight is in place. Two or more ICC Evaluation Service, LLC. /2 -inch -diameter (12.7 mm) concentric beads of supplied roof caulking are applied to the underside of the flashing. 6.0 EVIDENCE SUBMITTED Roof tiles are then replaced at the bottom part of the flashing. An aluminum sheet with. an EPDM skirt must be Data in accordance with the ICC -ES Acceptance Criteria installed over the flashing, and the roof tiles to be for Plastic Skylights (AC16), dated February 2008 reinstalled on top of the EPDM skirt are cut to fit around (editorially revised April 2008). the flashing as needed, and formed to fit the profile of the 7.0 IDENTIFICATION tile. Caulk supplied or specified in the installation instructions must be applied between tiles and the skirt to Elite Solar Systems Tubular Skylight components are seal the gap. Installation at the ceiling level follows packaged in boxes bearing the manufacturer's name procedures as described in Section 4.1. (Elite Solar Systems, Inc.) and address, the model number or size of the unit, the CC2 plastic classification, the 4.3 Allowable Loads: production date, the name of the .inspection agency (ICC - When installed in accordance with this report, the tubular ES) and the evaluation , report number (ESR -1761). skylights are capable of resisting positive and negative Additionally, a label bearing the name of the product (Elite loads of up to 20 psf (0.96 kN/m2), when attached to Solar Systems Tubular Skylight,) the model number or size minimum 3/4 -inch -thick (19.1 mm) plywood complying with of the unit, and a safety warning must be attached to the the applicable code, or to framing, with minimum 1 -inch vertical portion of the flashing. The safety warning must (25.4 mm) penetration: address risk of fall in compliance with Class I, ANSI 5.0 CONDITIONS OF USE Standard Z35.1, specifications. The Elite Solar Systems Tubular Skylights described in this . report comply with, or are suitable alternatives to what is e ... CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: INGRAM CASITA Calculation Daterrime: 06:31, Thu, Dec 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 004-INGRAM CASITA.xml CF1 R -PRF -01 Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer�Pertormance- 01 Project Name INGRAM CASITA -J` 02 03 Calculation Description Title 24 Analysis Project Location 79370 Canterbury 04 A City La Quinta 05 Standards Version Compliance 2014 06 Zip code 92253 07 Compliance Manager Version BEMCmpMgr 2013-3 (651) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.3 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (FT2) 450 15 Number of Zones 1 16 Slab Area (FT2) 450 17 Number of Stories 1 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (72) N/A 21 Glazing Percentage (%) 41.1% COMPLIANCE RESULTS+ 01 Building Complies with Computer�Pertormance- .... -J` 02 This building incorporates features that require field testing and/or verification#by a certified HERS 'rater gnde�,the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below'° j ENERGY USE SUMMARY 04 05 06 07 08 Energy Use Standard Proposed Compliance Percent (kTDV/ft) Design Design Margin Improvement Space Heating 0.08 0.12 -0.04 -50.0% Space Cooling 157.57 180.84 -23.27 -14.8% IAQ Ventilation 1.94 1.94 0.00 0.0% Water Heating 41.67 17.79 23.88 57.3% Photovoltaic Offset CITY OF L QUINIM 0.00 ---- Compliance Energy Total BL2°,06NG & SA EiY DEPT) 0.57 0.3% APPROVED FOR CONSTRUCTION DATI�L1340�& - Lb clI�II 1 15 2014 1HERS Registration Number: 214-No156882C-000000000.0000 Registration Daie/Time: 2014-12-1 7'- 2:4DEC Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-1106:32:18 By CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 ' - Project Name: INGRAM CASITA • " ° +� , - Calculation Date/Time: 06:31, Thu, Dec 11, 2014 - Page 2 of 8 ' • Calculationbescription: Title 24 Analysis i Input File Name: 004-INGRAM CASITA.xml - - REQUIRED SPECIAL FEATURES r The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. M Ducts with high level of insulation Cathedral Ceiling s• s •. . Exposed slab floor in conditioried zone r ' HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. !. Building -level Verifications: IAQ mechanical ventilation - . Cooling System Verifications: { Verified SEER r 1 �. 4 : ,: ► — - w - Refrigerant Charge ' Fan Efficacy Watts/CFM' t i'- ," • HVAC Distribution System Verifications: `• ; ` e - - z • - ' Duct Sealing. " ' Domestic Hot Water. System Verifications:,".. � ' ' ' � � � � , � , c � ,. • t, ti 4 -- None -- - .. 1' r • r b ENERGY DESIGN RATING r This is the sum of the annual TDV energy`consumption,fo`r energy use component ncludedm the performance compliance approach fo_ 0 Standard Design Building (Energy Budget) and the annual ` TDV energy consumption for lighting and components not regulated by Tale 24 Part 6 (`such'as domestic appliances and consamec electronics) and accounting for the annual TDV energy offset by an ' on-site renewable energy system. Reference Energy Use Energy. Design Rating Margin `Percent Improvement .. Total Energy (kTDV/f2)*-= ., 304.71 304.14 7 0.57 0.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) - y, BUILDING - FEATURES INFORMATION 01 02 03 ' ' 04 , .' - 05 *' 06 07 f . Project Name, ' Conditioned Floor Area (stt) Number of Dwelling ` , Units Number of Bedrooms - Number of Zones , Number of Ventilation; Cooling Systems ,. `Number of Water Heating Systems INGRAM CASITA, 450. 1 1 -1 0 1 -, ZONE INFORMATION 01 02 .03 04 05 ._ 06 _ 07 Zone Name , Zone Type . " HVAC System Name Zone Floor Area (tt2) _ Avg. Ceiling Height ' Water Heating System 1 , Water Heating System 2: ENTIRE CASITA Conditioned HVAC1 450• 9 DHW Sys 1 . _. Registration Number:' 214-140156882C-000000000-0000 Registration Date/Time: 2014-12-11 07:52:47 HERS Provider: CaICERTS inc.' . CA Building Energy Efficiency Standards - 2013 Residential Compliance ReportVersion - CF1R-10172014-651- - Report Generated at: 2014-12-1106:32:18 F . CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD , ;. - CF1 R -PRF -01 Project Name: INGRAM CASITA. Calculation Date/Time: 06:31, Thu, Dec.11, 2014 Page 3 of 8, -Y fA Calculation Description: Title 24 Analysis - ' '� - Input File Name: 004-INGRAM CASITA.xml' OPAQUE SURFACES, .,' 1 , rti ji f+ ` .. ,, , . +� 3 -� v- •, ti •u• - 'c. � � K } ,r � -j � f _ 01 } 02 •03 ` 04 Y 05 06 -07 08 Name`, Zone Construction • Azimuth .'Orientation Gross Area (ft2) Window Area (ft) Tilt(deg) s NE -144,-'- ENTIRE CASITA R-21 Wall 45 Front 144 48 90 SE -276 ' ENTIRE CASITA - R-21 Wall • . `' 135 Left 276 28 _ 90 - 0 - SW -144 SW -144 s .. ENTIRE CASITA R-21 Wall 225. Back 144 76 90 NW -276 ENTIRE CASITA R-21 Wall 315 'Right 276 32'' 90 .450 2 ` _ ENTIRE CASITA R-49 Roof Attic ` n Area (ft " "" 449 • ► Pitch � a • L' r ,r i� OPAQUE SURFACES - Cathedral Ceilingsi- +, ' •� ° , .� -• .,' 1 , rti ji f+ ` .. ,, , . +� 3 -� v- •, ti •u• - 'c. � � K } ,r � -j � f _ 01 • 02' 03 ' 04 05 - < t • 't '" .� f' y eS•:s i i.• -�``. - 06 07 08 09 . 10 11 !y- irr _ � j . .� ,�, '� �� � _ � f y.,.'t• ' �7 t, •w � k ;' �` � f � : i. �' , t �, { .Y f t ?`! �_'�� `- .: r ��• x ,r _ - .. d� ��, -. } 'rte •� ' • ' : tip, f „'.. � .•. • i..�,. _k t.: ♦ *` •�. ",' by t,. 1, , • ..ti �2 -„,� Roof. 'Roof' Roof Framin r - , <a , •, '"' `< Orientatio - • • Skylight Roof Rise Roof Tilt Reflectan Emmittanc g Name' .-Zone . Y z Type r ` n Area (ft " "" Area (M) (x in 12) ' Pitch (deg) ce e- Factor 450 .� ENTIRE CAS T • R-49 Roof Attic1 specify ] 1 0 5' 4 0.33 18.43. 0.1 r 0.85 0.07 i ,,' ' _ 71 ATTIC 01 107 . ."' ROOf RISe "s:a`r ' w COI1StrUCtlOn ` y Name Roof` Reflecfance Roof Emittance Radiant Barrier, ; Cool Roof. a , Attic Attic � Roof Cons ''' 4 _ 0.1 - 0.85 , ; Yes No's ^. `5• -... , t 'l x •4 *, •1 1 _ .TC _E .,' 1 , rti ji f+ ` .. ,, , . +� 3 -� v- •, ti •u• - 'c. � � K } ,r � -j � f : � � "...-�., r � � Yi�'�J f 1 +. > _ t , � .. �.. ! }. `4 r f ', n .Y �.. y, �, a i �^, : • F� • <•.t ♦},. .y, �, ', < t • 't '" .� f' y eS•:s i i.• -�``. - . F . � • .,`, y' . r . . r. ?a ° 3 �' Al s 4,4, i • t _ .� ,,, � t+ c .Y tj. �a .:� (°'. 4' r f ;fr`.. " 'j $'' •.�. J �'. c++ ,_ _ y- !y- irr _ � j . .� ,�, '� �� � _ � f y.,.'t• ' �7 t, •w � k ;' �` � f � : i. �' , t �, { .Y f t ?`! �_'�� `- .: r ��• x ,r _ - .. d� ��, -. } 'rte •� _ i..�,. _k t.: ♦ *` •�. ",' by t,. 1, , • ..ti �2 -„,� ; • t .° f' A ,. *�•. A�• t - ,+ : ' , t f _, 9. f ; ,, r J . �•+ o ; . f Y '1 i X t ji^ _ t t .. 1 T �^ ' ` •-,�, � } •�t l t, . •' ” `.Ta' F 1� 'r' ,L Y Y 4' .. , S.j .f+- � �t'' . , er. �� ��' � - f. .jr f,., 1 a.. _r f � ' �j .. ,4.. ,. •'' •, +• � •.. ' • ••y ^ • ` f� i. .a r . r Y �Lr -f .•i�� 4 _• 71 Registration Number: 214-No156882C-000000000-0000 - Registration Date/Time: _ 2014-12-11 07_:52:47 r HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance • Report Version - CF1R-10172014-651 t '. r " ` Report Generated at: 2014-12-1106:32:18 T. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: INGRAM CASITA Calculation Date/Time: 06:31, Thu, Dec 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 004-INGRAM CASITA.xml CF1 R -PRF -01 Page 4 of 8 WINDOWS 01 02 �Y `- f 03 04 i- 05 . 06 _ 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Height Width(ft) (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading 6080 Window NE -144 (Front -45) ---- ---- 1 48.0 0.32 0.25 Insect Screen (default) 3680 Window SE -276 (Lett -135) ---- ---- 1 28.0 0.32 1 0.25 Insect Screen (default) 36802 Window SW -144 (Back -225) ---- ---- 1 28.0 0.32 0.25 Insect Screen (default) 60802 Window SW -144 (Back -225) ---- ---- 1 48.0 0.32 0.25 Insect Screen (default) 2040 Window NW -276 (Right -315) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) 20402 Window NW -276 (Right -315) 1 . 8.0 0:32 0.25 Insect Screen (default) 20403 Window NW -276 (Right -315) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) 20404 Window NW -276 (Right -315) ---- ---- 1 8.0 0.32 0.25 Insect Screen (default) 10 solatube Skylight ,450 ( specify --45) • Cavity / Frame: R-21 / 2x6 1 .5 0.28 0.20 R 21 10 solatube 2 Skylight 450 ( specify --45) 1 .5 0.28 0.20 OPAQUE SURFACE CONSTRUCTIONS 1 d 1: 01 02 �Y `- f 03 04 i- 05 . 06 _ : Construction Name Surface,Typej , '; r Construction Type .., Framing Total CavityR�value Assembly Layers Cavity/ Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Deck: Wood Siding/sheathing/decking Roof Truss @ 24 in. Tile Gap: present Attic Roof Cons Attic RoofsWood Framed Ceiling O.C. none Roofing: 10 PSF (RoofTile) t Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 R-49 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 49 Over Floor Joists: R-39.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-49 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Tile Gap: present R-49 Roof Attica Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 49 - Roofing: 10 PSF (RoofTile) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 24 in. O.C. R 21 Exterior Finish: Wood Siding/sheathing/decking Registration Number: 214-N0156882C-000000000-0000 Registration Date/Time: 2014-12-11 07:52:47 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-1106:32:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: INGRAM CASITA Calculation Date/Time: 06:31, Thu, Dec 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 004-INGRAM CASITA.xml CFI R -PRF -01 Page 5 of 8 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value& Depth Carpeted Fraction Heated (slab) 450 ENTIRE CASITA 450 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa Not Required Not Required Not Required WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1. 1 .0% I WATER HEATERS �+. _'' ,r"g..._- STT,_.; . . 01 V02 )` . ;' 03 - 't ' 04 04:,� ... 06 07 OS Name Heater Element Type . " Tank Type TankVolume Y (gal) " Eriergy Factoor4 Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 `Natural Gas Small Instantaneous 0 0.88 30710-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/1 N/A N/A N/A N/A N/A N/A HVAC SYSTEMS 01 02 03 04 05 06 07 - Heating System Cooling System Distribution Floor Area Name System Type Name Ducted Name Ducted System Fan System Served HVAC1 Other Heat/Cool Heating Component 1 Yes Cooling Component 1 Yes Air Distribution 450 System 1 Registration Number: 214-N0156882C-000000000-0000 Registration Date/Time: 2014-12-11 07:52:47 - HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 Report Generated at: 2014-12-1106:32:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: INGRAM CASITA Calculation Date/Time: 06:31, Thu, Dec 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 004-INGRAM CASITA.xml HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 92 AFUE CF1 R -PRF -01 Page 6 of 8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 ' - Efficiency - Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11 87 14' No No Cooling Component system Name - Type - Insulation R -value .1 -hers -cool HVAC COOLING- HERS VERIFICATION 01 02 03, 04 05 06 Name 1 Verified' Airflow.... Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool r y',Required �' „ ° ' F _ 350 Not Required .. Required Required HVAC- DISTRIBUTION SYSTEMS_._.._ 01 02 03 01 02 �� . ._j 03 w. s 04:;:.; OS 06 07 08 Low -leakage . Air Handler Air Distribution System 1 -hers -dist . Required 6.0 Not Required Not Required Not Required Supply Duct Name - Type - Duct Leakage Insulation R -value Location Return Duct Bypass Duct HERS Verification . Air Distribution System 1 Ducts located in attic Sealed and tested 8Attic Attic None Air Distribution System 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Low -leakage . Air Handler Air Distribution System 1 -hers -dist . Required 6.0 Not Required Not Required Not Required Registration Number: 214-N0156882C-000000000-0000 Registration Date/Time: 2014-12-11 07:52:47 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 HERS Provider: CaICERTS inc. Report Generated at: 2014-12-1106:32:18 CERTIFICATE OF COMPLIANCE -.RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ' .,Project Name: INGRAM CASITA, ti Calculation Date/Time: 06:31, Thu, Dec 11, 2014 • Calculation Description: Title 24 Analysis " - - Input File Name: 004-INGRAM CASITA.xrnl CF1 R -PRF -01 'Page 7 of 8 HVAC -FAN SYSTEMS 01 _ 02 r.- 03 ; - 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification -+ HERS Verification , DwellingUnit �•7 19.5'" ,y - .; 0.25 HVAC Fan 1 Single Speed PSC Furnace Fan 0.54 •HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name - _ VerifleclFanWatt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.54 ' IAQ (Indoor Air Quality) FANS , 01 _ 02 r.- 03 ; - •04 05 06 " r _ Name ,_ ; • IAQ CFM "' - IAQ Watts/CFM -•; IAQ Fan Type ; IAQ Recovery Effectiveness(%) -+ HERS Verification , DwellingUnit �•7 19.5'" ,y - .; 0.25 v Default * , 0 r Required , .•.. ,.s 1 y r` r•� F - 'r r . � `r •r i .17 iL �•r . , .• :� ,mak. a r .. i - _ .-F .�. a- - ♦ ` t•• • a �t• + - �.y >.P , . ': f� ` r •r, t ' * ,• , , r ^ 1 �. . � ' Registration Number: 214-N0156882C-000000000-0000 ' Registration Date/Time: 2014-12-11 07:52:47 ' HERS Provider. . CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014651 ;• Report Generated at: 2014-12-1106:32:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: INGRAM CASITA Calculation Daterrime: 06:31, Thu, Dec 11, 2014 Calculation Description: Title 24 Analysis Input File Name: 004-INGRAM CASITA.xml CF1 R -PRF -01 Page 8of8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify.that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ� Company: Signature Date: TITLE 24 OF THE DESERT 2014-12-11 07:51:34 Address: CEA/HERS Certification Identification (If applicable): 44890 SEELEY DR, NA City/State/Zip: Phone: La Quinta, CA 92253 760 2781840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of -the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. - 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or'system design features identified�on this Certificate o Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted•toiethe enforcement agency fob approval"with thi uildmg permit application. - Responsible Designer Name: ¢ Responsible Designer Signature: Eduardo Nava Vy I �� Company:. * m - Date Signed:" Nava Design Group,� 2014-12-11 07:52:47 Address: License: 49132 Valle Posadas t' N.A.- City/State/Zip: Phone: Coachella, CA 92236 _ 760-777-3260 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies R information. Registration Number: 214-N0156882C-000000000-0000 Registration Date/Time: 2014-12-11 07:52:47 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-10172014-651 .CITY (-)F LIQ UUIN.l fi BUILDING & SAFETY DEPT. APPIFF110VED FOR CONSTRUCTION HERS Provider:. CaICERTS inc. Report Generated at: 2014-12-1106:32:18 \ � : \\\: �� \ ���� z� .. � � � / v �\�`�.\ � :� = d w � \\ £HeBgtRle .. �� jj)R»j{� Z ))\§G� 2G� ^ j\»�a�u:� \: \. , ,\.�\. . . .. { \, \\ �� `� \ ; w«.:< w .�y , . 2...�a�. AIR ANDLER DALLAS,,T-X MODEL m R — SERIAt NO 0,04 — To'. .-io"H44 M R410A- -CWUOG - C 0AWY 4W P -M REFRIGEAlE N T TYPE Pit Imaroft, Rpm ..826 pin y 'VOLTAGE R Itso., !#AX 0 P #,W IN, TA 0 0� MOTOR, op ANAX-00yul MAP., .T of c MAW"-oppw Omni) 4w R ROW" Aht 254.0.. TO "lw mall ,pog'! PGA WEST RESIDENTIAL ASSOCIATION, INC. September 24, 2014 Mr. Dennis Ingram Re: 79-370 Canterburyposed Architectural Project-Casita Addition/Pool & Spa Dear Mr. Ingram, At our meeting on September 23, 2014, the Architectural Committee presented a modification proposal to you to satisfy the'Committee's building layout concerns and compatibility with the community.. Your review of this plan revision, to use the existing patio and roofline as the farthest extension of the new casita rear wall, was accepted by you and the committee. This maintains your- plan request layout, but eliminates the extended roof over the rear stoop/patio slab. As shown on the attached two `marked -up' sheets, the rear line is shown and the casita rear roof is hip style. The 5 -feet 0 -inch set -backs to be maintained and the pool equipment to have sound and sight baffle walls. Additional landscaping is to be included with the landscape/irrigation plan submittal. Based on this understanding, the preliminary plan with the modification is conceptually acceptable. The adjacent homeowners that were notified of your proposed project provided their concerns and comments in response. They will be notified of the Committee's review and meetings to finalize an acceptable plan. The preliminary review process should be complete, subject to the agreed changes. Should there be any questions, please contact us before proceeding. Thank you for your participation and assistance in the Architectural Variance process. Cordially, C� _ Kel y cGalliard. Operations Manager For the Architectural Committee KM/bvf Cc: Architectural Committee 54-320 Southern Hills, La Quinta, California 92253-5665, Telephone 760-771.-1234 FAX 760-771-5125