BSOL2016-0084sin.#
city. Of LaQUintd
Building 8L Safety Dil&on
P.O. Box 1504,78-495 Calle Tampico
La.Quinta, CA 92253 -:(760) 777-7012
Building Permit Application'and Tracking Sheet
Permit #
'�Svi,2o�10'f8
Project Address: 49100 Avenida Anselmo
Owner's Name:. Rob Lange
A. P. Number 658280005
Address: 49100 Avenida Anselmo 7J
Legal Description:
city, sT, zip: La Quinta, CA 92253
Contractor. Palm Desert Contractors
Telephone:
Address: 78333 Darby Rd.
Project Description:
City, ST, Zip: :Bermuda Dunes, CA 92203
Install 30 Suniva 335w Solar PV Panels
Telephone: 760-250-9095 ; .>z ' A�
and 1 SMA Sunny Boy.1 OOOOTL inverter
State Lic. # : 477507 ' City Lic. #
Arch., Engr•, Designer:
Address:
City., ST, Zip:
Telephone:
State Lia ;„ ... _.:y� ,• '- ,r
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft_: # Stories: # Univ:
Name of Contact Person: Jock Lefebyre
Telephone # of Contact Person: 760-250-9095
Estimated value of Project 0 p
APPLICANT: DO NOT WRITE BELOW THIS UNE
sE
Submittal
Req'd
Recd
TRACKNG
PERMIT FEES
Plan Sets
Pian Check submitted
Item Amount
Structural Calm
Reviewed, ready for corrections
Plan Check Deposit. .
Truss C21cs.
Called Contact Person
Pian Check Balance
Title 24 Calci.
Pians picked up
Construction
Flood plain plan
Plans resubmitted..
Mechanical
Grading plan
2" Review, ready for correetionsfeszue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE.-
''" Review, ready for correctionsf=' a
Developer Impact Fee
Planning Approval.
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
PPMOMAPPp- QN, 45-311 Golf Center Parkway, Suite B
Indio, CA 92201
Phone: 760-770-3303
Fax: 760-391-4230
BuildMaterials and
Constwction Services
05-18-16 40-4 i wv
Lange Res
049100 Avenida Anselmo
To Whom It May Concern,
BMC designed and built the roof trussesfor the above mentioned. home;.We.did include the additional 2
lbs. per square feet load needed to;support solar panels. We designed for a total load of 44 PSF.
Mike Goodman
Design Manager
BMC Truss
1. SCOPE OF WORK: INSTALL A 10.05kw SOLAR PV SYSTEM,
1 SMA SUNNYBOY 1000OTL—US INVERTER AND
30 SUNIVA 335w OPT 72cell SILVER MONO PANELS.
2. THIS PROJECT SHALL COMPLY WITH ALL 2013
BUILDING CODES AND LA QUINTA MUNICIPAL CODES.
3. ALL ELECTICAL DEVICES AND EQUIPMENT SHALL BE
WEATHERPROOF TYPE NEMA 3R.
4. NO BATTERY BACKUP SYSTEM OR UPS IS TO BE
INSTALLED WITH THIS SYSTEM.
5. THIS BUILDING IS A SINGLE STORY HOUSE.
6. THE CITY OF LA QUINTA WILL NOT BE HELD RESPONSIBLE
FOR ANY ROOF DAMAGE WHILE INSPECTING THIS PV SYSTEM.
7. ALL CONSTUCTION SHALL BE DONE DURING NORMAL
CITY OF LA QUINTA WORKING HOURS.
8. FALL PROTECTION AND ACCESS TO ROOF WILL BE PROVIDE
AS NEEDED.
9. PV SYSTEM CONDUCTORS SHELL BE IDENTIFIED AND GROUPED.
THE MEANS OF IDENTIFACATION SHALL BE PERMITTED BY SEPERATE
COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED
MEANS. THE MEANS OF GROUPING SHALL BE TIES OR SIMILAR
MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO
EXCEED SIX (6) FEET.
10. PV EQUIPMEN AND SYSTEMAND ALL ASSOCIATED WIRING AND
INTERCONNECTIONS SHALL BE INSTALLED BY QUALIFIED PERSONS
SHEET NUAIBERS
SHEET TITLE
PT'-1
SITE PLAN
PV--2
AMCHMENT PLAN
PT7 3
TVIRERING PLAN
PV-4
1-LINE
.PV-5
SPEC SHEET PANEL
PV-6
SPEC SHEET INVERTER
PV-7
SPEC SHEETS
110
]f
118,10'
130
9
ROB LANGE RESIDENCE
49100 AVEN DA ANSEMO
LA QUINTA, CA 92253
APN: 658280005
I'SOLAR PLANS DESIGNED BY.•
A ism MICHAEL O' NEIL
P.O.BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lez—comm. com
l > LEXCOMM
� 49f00 Licence C-10 # 918267
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
kTE b L UI BY
1 Ww/ S�tS"n6+r►ti ��
1,0'
momm a" t./
SITE PLAN
I" TO 30'
,'ONTRACTOR/INSTALLER
PALM DESERT CONTRACTOS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E—MAIL:
Palmdesertroofing®gmail. com
B License # 477507
Calr. 7'0LL FREC
r
f-800
<xz-4133
mo .ugmt AlYS
A mrr r xr nm
-
04105116
bpi comamnms ar
AFMtDVM er:
z6 16
WE dolp
DME
FAST JACK,'
ROOF STANCHIONS
SOLAR PANELS
FAST JACK
FLASHING
(EXISTING)
I" PITCHED, TORCHED/ROLL ROOF
2"X6" 24" 0. C.
1o°
'!?! EONAL !L' EONAL VERTICAL
30 SOLAR PANELS
UNIRAC
L BRACKET
RAILS &
CLAMPS
FAST JACK
ROOF STANCHIONS
if j I' r_I I I I I I I l t'
A T TA CHMENT PLAN
I" TO 10'
SOLAR PLANS DESIGNED BY. -
ilk
^—`—veNruaEs --
MICHAEL O' NEIL
P.O.BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lez—comet. com
LEXCOMM
Licence C-10 # 918267
'ONTRACTOR/INSTALLER
PALM DESERT CONTRACTORS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E—MAIL:
Palmdesertroofing@gmail.com
B License # 477507
'T'OU rKet
r-800
4z21173
m'o ' I'm
04105116
DESIGNED BY.
DATE
4��
04, 22 16 ;
cORREcnms BY DATE i
APPROVED Dr. DATE
P V-2
ti
6"x6" JUNCTION BOX
�� SMA INVERTER
J J J J W/INTEGATED
uj
z z z z DC DISCONNECT
a a a a
6"x6" JUNCTION Box
ARRAY 3 a a FUSED DC COMBINER BOX
a a
3 RUNS
J
w
PV—WIRE a SEE LINE 4 PV-4
PANEL TO PANEL
UNDER PANELS
IN 1 /2" FMC WHERE
NOT UNDER PANELS
THROUGH ATTIC ARR 2
W
w
El
a
J
W
ARF AY 1 Q
a
PAN ► ANEL w
VANEL I I NANEL
200AMP BUSS
175AMP MAIN BREAKER
60AMP SOLAR BREAKER
W E w
Z z
a i a
6"x6" JUCTION BOX
6"x6" JUNCTION BOX
A/C DISCONNECT
SEE LINE 8 PV-4
2#10 RHW-2
IN 1" FMC
1PHASE,1NEUTRAL,
AND 1 #8 BC GROUND
JUNCTION BOX TO
JUNCTION BOX
THOUGH ATTIC
SEE LINE 6 PV-4
2#10 RHW-2
IN 3/4" FMC
1 PHASE,1 NEUTRAL,1 #8 BC GRID
JUNCTION BOX TO
JUNCTION BOX
THROUGH ATTIC
z:�3 #4 ROMEX W/GRD
SEE LINE 20 PV-4
2PHASE,1 NEUTRAL,1GRD
IN ATTIC & WALLS
AC DISCONNET TO 40amp
,BREAKER IN MAIN PANEL
3 RUNS
SEE LINE 12 PV-4
2#6 THWN-2/W GRID
N 1" PVC SURFACE MOUNTED
'hPH ASE,1 N EU TRAL,1 GRD
FROM COMBINNER BOX
THROUGH J BOX TO
DC DISCONNECT
3 RUNS
SEE LINE 10 PV-4
3#10 RHW-2
IN 1" PVC SURFACE MOUNTED
1PHASE,INEUTRAL, 1#BBC GRID
FROM J BOX TO
COMBINER BOX
3 #4 ROMEX W/GRD
SEE LINE 16 & 18 PV-4
2PHASE,1 NEUTRAL,1 GRD
THOUGH ATTIC & WALLS
FROM INVERTER THROUGH
JUNCTION BOX TO
AC DISCONNET
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
WIRE PLAN
I" TO 10'
M R PLANS DESIGNED BY.-
scv,�..Ar2
MICHAEL O' NEIL
P.O.BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lex—comnL com
LEXCOMM
Licence C-10 # 918267
0-NTRA CTOR/INSTALLER
PALM DESERT CONTRACTORS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E-MAIL: -
Palmdesertroofing@gmail.com
B License # 477507
1 TOLL I"RE£
-80a
F11-
10133
04105116
05/,23 16
CORRBcTum BY DATE
4��
05/31 16
o mc,"Is I,
1PYJ3
}}
CORRECTIONS MADE
TO CORRELATE WITH
DRAWING.
SUNIVA-OPT335W-72-4-100
1
110/1
STRING
)ULES
J10
;E
ELECTRODES
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
8
!HW-2 WIRE
K RUNS 2i10 RHW-2 IN 1'
AND 1ffl BC GROUND
9
(UNCTION Box
G X6 x6
RH IN I"
ND 1 D OUNp
SUR
GE MaUN DON OUTSIDE
i
)C COMBINNER BOX
SL COM 1J w IO
JHWN-2 W1RE
Zj§ h{MN-2nn IN ` Pv
SURi
ACE MOUNTED ON aUTSIDE
3
OC DISCONNECT
INTECR06MO W{TH SUA INY
4
MA INVERTER
SUNNY BOY 100CUTL—US
}}11ROMEY
VARE
17
JUNCTION BOX
m %5
}}
18
ROMEX WIRE
3 f+OVExw rd
I9
I,C DISCONNECT
SO 0 80n DU222RP
}t
I
RAKR
4 V UPEAKFR
}}
}}
AKER
om 240.1 I
-- — .1.1.1 —.ter..
BOND IS IRREVERSIBLY SPLICED FROM PANEL
ARRAYS TO AC GROUND ELECTRODES
SYSTEM CALCULATIONS
200AMP PANEL
200AMPBUSS/175AMP MAIN
60AMP PV BREAKER
DC CONTINUOUS CURRENT:
STRINGS 1,2 & 3
Isc x 125% = 9.66 x 1.25 = 12.08amps
AC CONTINUOUS CURRENT:
SUNNYBOY1000OTL-US INVERTER
48.1 A X 1. 25 = 60A
OVERCURRENT DEVICE 60A BREAKER
DC & AC CONDUCTOR SIZING:
ALL CONDUITS AND WIRES ARE IN
ATTIC OR WALLS THEREFORE
NO TEMPERATURE DERAT10N
FACTOR NEEDED
DC SIDE: #10 ® 40A
CONDUIT FILL = .8
40A X .8 X .82(TEMP CORRECTION)=26.24amps
THEREFORE 26.24a > 12.08a
DC CONDUITOR SIZE #10THWN-2
AC SIDE: #4 ROMEX ® 85a
85 X .82 (TEMP CORRECTION)= 69.7a
THEREFORE 69.7a > 60a
AC CONDUCTOR SIZE = # 4 ROMEX w/grd
SINGLELINE
30LAR PLANS DESIGNED BY.•
` ^ �L AR
MICHAEL O' NEIL
P.O.BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lex—comm. com
LEXCOMM
Licence C-10 # 918267
ONTRACTOR/INSTALLER
PALM DESERT CONTRACTORS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E—MAIL:
Palmdesertroo.ftng@g7nail.com
B License # 477507
role: rcr.� �x�e
i—sao
42x--4v.33
m nOREIM Iyrs
ewer Ica aIo
04105/16
DMIGH D BY:
DATE
4��
05/23 16
OORIE(. MS BY DATE
05/31 16
Wl"MUIrimb U7
FV-4
PLANS DESIGNED BY:
ENGINEERING EXCELLENCE
Built exclusively with Suniva's premium ARTisun
Select cells, providing one of the highest power
outputs per square meter at an affordable price
■ The leading US -born, US -owned crystalline
silicon cell and module manufacturer, spun out
of Georgia Tech's University Center of Excellence
in Photovoltaics: one of only two such research
centers in the U.S
■ Suniva's state -of -the art manufacturing and module
lab facilities feature the most advanced equipment
and technology
QUALITY & RELIABILITY
■ Suniva Optimus modules are manufactured and
warranted to our specifications assuring consistent
high performance and high quality.
• Rigorous in-house quality management tests
beyond standard UL and IEC standards
■ Performance longevity with advanced
polymer backsheet
■ UL1703listed Type 2 PV module
• Passed the most stringent salt spray tests
based on IEC 61701
■ Passed enhanced stress tests' based on IEC 61215
conducted at Fraunhofer ISE'
• PAN files are independently validated
MANUFACTURED IN '1i►
Georgia & Michigan
n-)11IVa
y. o„1s'
SUNIVA OPTIMUS`p SERIES
MONOCRYSTALLINE SOLAR MODULES
OPT SERIES: OPT 72 CELL MODULES (SILVER FRAME)
optimus-modules are known for their superior quality
and long-term reliability. These high-powered modules
consist of Suniva's premium ARTisuur Select cell technology
and are designed and manufactured in the U.S.A. and North
America using our pioneering ion implantation technology.
Suniva's high power -density Optimus modules provide
excellent performance and value.
FEATURES
Utilizes our premier American -made cell ^'
,11SA.
technology, ARTisun Select'
4' Superior performance and reliability; ctllianced
stress tests conducted at Fraunhofer ISF
Module families ranging from 325-340W
Positive only power tolerance
Marine grade aluminum frame
with hard anodized coating
f Certified PID-free by PV Evolution Labs (PNIEL)
Made in North America
Qualifies for Ex-Im Financing
1000V UL
25 year linear power warranty;
10 year product warranty
CERTIFICATIONS
a .0VEL
etCf1CIXG 9LLIx
.11-11
3 busbar cell
S busbar cell
PV module: Suniva, 0PT340-72-4-100
cwr Vdeg. 0V)as■
Fu—dl.. b.(Wlrtr).ndTr—p....
crarsr .n'c
fit leyHlek • I�q..r lr,.w
s eer+sr�t:. ss�.eors �tr�''i
.� rlsares.u.r ur.w
o to m 1a
vdog. M
S
A
_k
UStA
N
o �'R{M1HG
r
a e0�
0 1 t: 3S
YE AR)
( PLEASE RECYCLE
.U11 `, 'W i;'Ev SI
OPTIMUS SERIES: OPT.72 CELL MODULES
ELECTRICAL DATA (NOMINAL)
Power Classilicalion (Pmax)
1325 W
330 W
335 W 340 W
Module Efficiency (%)
16-66%
1&92%
1T 18% 17.43 %
Voltage at Max. Power Point (Vmp)
37 5 V _
37 6 V
37.7 V 37,8 V
Current at Max. Power Point (Imp)
8.67 A
8-78 A
8.89 A 8.99 A
Open Circuit Voltage (Voc)
45 8 V
45.9 V
459 V 46.0 V
Short Circuit Current (Isc)
9.42 A
9.54 A
19.66 A 9, 78 A
.-=i Tc`..11a',
o, .T :xah s^�l r_ rr:,�_:,�. .., fS'C
CHARACTERISTIC DATA
Type of Solar Cell
High -efficiency ARTisun Select cells.
3 and 5 busbarapllort9 available
Frame
Silver anodized aluminum alloy
Glass
Tempered (low -iron), anti-rellective coating
Junction Box
NEMA IP67 rated; 6 internal diodes
Cable & Connectors
12 AWG (4 mm') PV Wire with multiple connector options
available, cable length 1300 mm
M ECHAN I CALS
Cells / Module 72 (6 x 12)
Module Dimensions 11970 x 990 mm (77.6 x 39 in,)
Module Thickness (Depth) 38 mm (1.5 in.)
Approximate Weight 23 kg (SO,7lb%)
TEMPERATURE COEFFICIENTS
Voltage
0, Voc(%Pc)
1 -0335
Current
a, Ise (%/=C)
;OA47
Power
Y, Pmax (%/'C)
-0420 1
NOCT Avg
(4- 2 C)
146.0
LIMITS
Max System Voltage 1000 VDC for IEC, 1000 VDC for UL
Max Series Fuse Raling 15 Amps
Operating Module Temperature 4WCto+85'C(40'F1o+185'F)
Storm Resistance/Slalic Load Tested to IEC 61215lor loads of 2400 Pa (50 psi);
hail and wind resistant
fi.n,;., ,: �:, r•...�It.�ri,!'r!��,. •Ir.,'.at.:al::r•.1,.,^;-l'i. ,. ,..,�-�v.. ,�I: �.r.,, ,-..rr,
r-'.,.,' 114:,� OPT EC.,. r.r..�
Please read installation manual before installing orworking with module.
HEADQUARTERS Suniva
5u5 Poacham rduahtrr LISA
Fb,r_ms ., Gojir 30002 USA
TW:.t 401 t�2700
R 71- _ IW _ www.suniva.com Theerillla�ce of 5o4r Mnd. S.nslhle'
L ik — —
i0k
SU�►rt
MICHAEL O'NEIL
P.O.BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
7nick®lez—comm, com
LEXCOMM
Licence C-10 # 918267
'ONT-RA CTOR/INSTALLER
PALM DESERT CONTRACTORS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E—MAIL:
Pc&lmdesertroo.ftng@gmaiZ.com
B License # 477507
CatL TOLL FREF,
?—go0
i22_4132
no err■v a■a
e■nleeed rtvo
04/05/161
013K M g1;
DAZE
04,126 16
C0FWEZrKXS BY
APPRUVIED 9T: VAIL
J Vd6
NOW AVAILABLE FOR 240 V
Innovmfva Economi cal Relia b b
Convenient
•FIT ivaformarleas5MAkveaer •Hardirmneffkkncyaf9B.m •Opir-001'Loclheempkiesura
I- b.er O" haem rdma.wHh •Cl .1-dhgca: ofelanardmi.5% masag.mant
•InViaydDGdbconsecl
UL 17A I • Superlar fdPPl rwUno wlb
•SMd Power ga Lsrw.rfor drw•
•FialinvarlerweharafauhcireuBlniar• OptDracs'
phase grid ao nnanaan
mpl.r islyco daerdinglo UL 1699E • Tramiarmarl.ss,wA H5lopobgy
•Wasagridcleompali6l.
SUNNY BOY 9000TL-U S / 10000TL-U 5 /
11000TL-US
Transformerless design, maxrmum energy production
Thin *umy Bly M-W serles is L/L KSlad fcr Ncrth Amorlc0 and feniuren Sfr Xn ihncnitlye hf 5lapal�raluliing Insvparior
04dendes of rnwe fhan 98 Perz4 4 and rrnrrtinlehed salnr paaet prodl--tiun. ilse design reduces w-Eight,
'f A-44ea thalzpoad of pay6eckand prbvldea optlmurnvalue forafsy resldentidl ar d man trcl[z6d 4ommercal pVsysr.�n the
S 5ur ny Say T1-[1S seriee for Wdh Amerko. is the idasl chrAce in irotaf arrnerlesa fechnolc'xgy -
"'E
tMid�sr 11
`N`A^:J-S f/1,�,-A.rnerica eon
T•dniaal ado
Inpul f DCf
Mm. usable DC paver IU cas p " 1;
MM. inP,r vahage
MPP -lapin nnq. / rNad Input vohogs
Mir rpLd rdhgs/ irdw Input vukaga
Mu. irvu Wronl
M-- lrPsi cursnl p ar ,hi.g
Nuarbor of Inespmdfo MPP h+pws
5nmgs par M FP inpN a Cond*. got
c.�- fAq
Rokdpower/rmxopparm ACpaw,,
Nominal AC wYogs / nominal AC rdag r mango
AC paver fr.9orncy / range
Mot output errant
,. • r -+.w rr raua F�
. rl • = phase.
MaNWy
CEC cfii:" / mac effdw cy
Pra1-,6v- d.vic.s
DC tesan P310dry pmk¢llon
AC 4rortalrcuk currant capability
All fsebs. %&a m1duak~ me.Ledng l,N
l4oiauhraresrtlnlempnrtacootdes b UL 16MJ
Prer.c6 elms
Ovarvollegs arlsgory
General data
Din.nrons (W
Diresrtbns a1DC Diseanrmd IW / H / DI
Waight
Waighrsf Dc Dheonn.d
OpereHng hnilmraLre mega
yphool)
rapohm,
Coding conapl
D-gao. of proecro,
Dog —ail rebelin elewwbon ores
Mau pmNsnNe yoke far rlaoro h middy Inmmndoneh g;
F.,w—
DC cmnwlion
AC cmneator
Qvlay
Irdr.f— RU35 / BA. -A / W&Cenn.d
Wcnanl1.10/ IS/20ymn
Cerdimr-s and nppru oh [man avai666 an requsslf
-Standerd6*06s 0()00e6116bl a -Net eve iehl.
NOTE: U5ktw19n 3hlp wA gmyBds Dad atrordnal oo dhors
rype deegnolan
AccassOrfea
awry ru'rCw,k rr-c —
v msFxl
:ecesyta uN�^wr
� :It 5vrmlAe.w.
UPWANN41
�a.hn Is�rs
�asusteNe
• e swsa ro.-, eo6,..•s.
�+e Iklsrls-roof
Walrr'6nr.er{yA4,�
i Standardiyakln
SaVDIJLaO
a ClpfanalfiaYrr
- Nd auol hhle
Dale m nomi nl aaedlfnes
Sunny goy 10000TLUs
20B Y
240 V
Imco W
600 Y
10430W
J(X)V- 400 Y / 345 Y
600Y
300 V/ 360 V
045 Y - 4B0Y / 374 y
35 A
345 V/ My
JSA
302A
1
302 A
6
1
6
16QCM7 W / 16050 vA
SOB V/1 H....6 ZF
d0 Hz/59,3 Hz... 60S Hz
.740Y/21I Y-2d4Y
48.1 A
60 Hz /34.3 Hz.. d0.3 Hz
I
417A
1/2
reo%/98.6%
70x/P97r
f
f
•
f
I
N
4to/ 61S/24pmn [1B4/s4,7/q,3IkAI
1 B7 / 297/ 190 mn [77g / 1 17/ 7S Tray
33 ig/ Tg Ih
3S hg/ a 16
4D •C_.+60•C/.40'F.-+140 -F
aade[Af
a. Is W
Tmnsfornrerlaa
H9
QP1CWl
NEMA 3R
NEMA 3R
100%
SawwlarrNml
Senwl.rminal
7eod In.
O/O/O
•/o/o
Lit]W,
1.11-1 PK IEEE15A7, FCC part 15 [Clms Ad aL CAN/CSACF22 14
SB 10000rUS12
i" R PL,"S DESIGNED BY.•
Ak
mr uT
MICHAEL O' NEIL
P.O. BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lex—comm. com
LEXCOMM
Licence C-10 # 918267
�ONTRA CTOR/INSTALLER
PALM DESERT CONTRACTORS I
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E-MAIL:
Palmdesertroq.ft g®gmail. com
B License # 477507
Ca1L TOLL FREE
1-800
422—ff23
Tev rMunt; Mrs
04105116
a ey:
cA�
04a 16 +
OOfIiaEClsp BY DAZE
05/31 16
6 WiTCip S ar DATE
SOLARMOUNT® RAIL OPTIONS
`Vs most versatile mounting system
',A�,19c unl• HD
HD II„yrvy duly) rail ad,ls Ihr �nla�rAounl advanUdrt
ro Wl'aleTnp,•, U-lAz lxp separ�Ie data zl,eclzJ
a rd custom apPica[ipn: lha! rcquim long zpanv
ATTACHMENT OPTIONS
Flexible Components Spc,,d Installation
staodofh
Use ztandalfs whenever n.zhrd insl_Ilalians
�a arerrgnirrdonliMrnors,rarcaampl,Two-
p,prp aluminum standofir, l I„w precise Plarc-
mem nr
a narl,i„g spa,rpa bse ym, m me
imlallaho„of the clan JuR 11 if
All surdprnrppsmnrioroa,rlanaare
heights: 1, a., and T m,h,, apprepriale
na:hrn, are ova dablc
_ - _ Sandaled L-fret
-- slaMa,J fnrgmu„d ,want inslallal inns on
_ - miJcnlial and rmnmcrcial mortpps,we t-r
�'� alone abure a,nhN111P n d.rr,hW-ar,n
rn d,,dlor wJh Otl Ion slandnr1. flaunt
standard orlighL rails Configure W either of
rail Mighb, pnu pr—lmg air now 1.,
a olio& the o ther afcnng c1rn L'. the mar
apsll,cfics
strut -in -Tube Ry!p Lers
n,ek4ly sellheprcr,ze til[angle requimJ Styles
ay.,ileble far high profile is nr,legs err
_ - - ��rail)and law prohle imlallalinns
E is series often three leg le ,n, sa Lhal you
- anadjuzllaenacUylhpllllanglelaawanL-
up Lo a nla.im . 0f""'rns-w n_
,.Ll,ng and dnlliug al the jab site
Standard bolnrhfount'
standard mil Ilimale lleubilit. Indudin y Ap vet"
gives youil Y a rf 7--.�n
bpllam maunling and tilt -LIP aplipns 46,-rI 4,,lrsrr--in
rI v Sr•w .,a=:-!r�•sr.
MODULE MOUNTING _ .I tt,el „Inv,ra,rlr.Ill
-.ee.l as, l...l,e. (.�..2s yea .ar,-rr
assembly sequence Is Your Choice rn..,.d
Top IVluunlinb Clamps bottom Mo u n tiny Clips
Idr.,l car hush mount applira- asp W R"mpunting clips I1 Tile Host
such as residenlial roprlops, — (sLanJard a rid Hn rail only) - f elide fr�m,es1 alumin„m, the file hook
wrero ll is matt 1—wnuo whe,v ver you can ter to a ud,mcm pmvidcs soh Mromrt with .
stt efoalings and rails before preewemble line array ruing _ earl-efferllsa•splubon for harml.,1 h
nslalllr,g module by maunling ,undid' coounlmg hobs pans
damps stturcly grip any "InL or simpH lit the clip iota its rail Lk loots, all required last bobs and ha,Jware
Lhp ruod„le rm,rc, cream, you slot averll:e In. -Long bolt I. nee are included Nefer In l h, h le Mak engineering
from the cpm:mina or module >,><,m sonnertinn Adjust the data ror n,,, old c,p,bih Lic,
....rAR Icahn clip posilipl, al,ywl,ere All
Lhp rail slat '
INVERTER
PANELBOARD
DC CIRCUITS,
JBOXES, ETC.
AC DISCONNECT
SERVICE PANEL
DC DISCONNECT
KEY BENEFITS
of solarAAci Rail
Maximum flexibility
Flush, high -profile or
low -profile configurations
Roof or ground mount
Pitched or Flat roof
Ease of installation
Installer -friendly components
Minimized penetration with
longer attachment spans than
competitive products
Designed with customer input
• Grounding and wire
management options
Complete technical support
Installation and code
compliance documentation
Online estimator
Person-tc-person
customer service
Core component for Unirac
mounting solutions
Three rail options to
accommodate anyjob site
• Incorporated into other
major product lines
WUNIRAC
UNGROUNDED DC
CIRCUITS & CONDUITS
Product Data Sheet DU222RB
Safety Switch 60A, 240VAC, Non- Fusible,
General Duty, 2-Pole
Cl® SCALudE D
7.ehn1ra1 LharacterisDv
Wile Sze
a1ew12AxD(All-111 t 12 AWG(F)
Actor,
lgleThwa
Amen. Far"
IDA
APPnwU,
WL Well Vie Ferri, Eyf_
Erxeatro Type
RapPlmlam lee sla Pk (Irem iou—)
Erltl—"
NEDAaR
Feetorylklelke Heinle
He
McPonm votes. loch
ara,AD
Disco —Tye.
Nl izdt
TanialType
I„s.
Mernlnv Type
mrboi
Tio. a Dull'
aatrra Ddy
Nunb4rafFel.
2-Pd.
Shlpping and Or&dng
U,oiseq
n I C2-sawn vni n y WWZYa{ V- 29) Ai•. in E uV a
DaceuaaehesLb
Di
DnN
W MEM4914M
Well ll
4,7lee
Awlblgt, Cede
9ok 11—This tenh moor, deadln mrdialrited-fialAa
Ralumetlly
y
Ccurdry Pei
fat
A6 [UrdYdr, sec... n, an J pogo oarve loco Inn. lona, pure ass.. Lgnfm.Aon U Ct IrWrmaettr y'Rn Imft a—t
•m.s rme cars r� Schneider
QEIectrlc
Compact (SL Series) Soler Combiners
Stare
• The idea compact solution for commercial and residential
rooftop installation. with light space sndNEMA 4X
requirement.• offering maximum performance in a emdler
''— physical footprint
•• • -w • Complete Technical Specifications
1 • Locate AuthoeixedDistributor
�- — • Contest Local Sales Represente -
• ptoduct Detail,
Rehearse.
• Certifications
• Rated for continuous operation at 50-C
• 15Amax farexixe
• EMonrr Bursma an series UL2579 fart -acting 600 VDC Ms dgetFuse. provided as itan dard with
fusedmodels
—.ame4a.a—
Features
• Avail rbla it either four or six input circuit models to match the most common customer
recta rr ents for a compact combiner
• Coalinuous duty rated at 60OVDC
• kM'4A47C fiberglass 08 is 08 x 06 enclosures with captive stainless steel saews and formed -in -
place pdyurethmse seamless gasket provided m standard
• Third party certified to UL1741 and CSA Standard C22 2 No 107.1
• Touch•. afe fuse holders and power distribution blocks for safe operati an
• 9= output terminal.
• Comfiguzed forp usitive and negative grounded araye•
• Ground blocks irtcluded
• Rated for continuous operation at 50*c
• 15A max face size
• Eaton's Bussmarm s eH es UL2579 fast -aching 600 VDC M dget Fuses provided as standard with
fused models -
PLANS DESIGNED BY.-
ve.n rga TtEis
MICHAEL 0 r NEIL
P, 0, BOX 14285
PALM DESERT, CA 92255-1485
PHONE: (760) 801-9133
E—MAIL:
mick®lex—comm. com
LEXCOMM
Licence C-10 # 918267
ONTRA CTOR/INSTALLER
PALM DESERT CONTRACTORS
78333 DARBY RD.
BERMUDA DUNES, CA 92203
PHONE: (760) 250-9095
E—MAIL:
Palmdesertroofing@gmail.com
B Lticewe # 477507
Calf: 7Y7I.f. FRF'E
r _,goo
fP2—�r3&
are sonwrcarya
Iltrlt0ax rDrf aIG
04105116
DESIGNM BY: DATE
(�i�
04126116
0ORMC7101S BY
APPROyiD BY: DATE
1pV J7