BRES2017-02951
78-495.LALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Permit Type/Subtype: BUILDING RESIDENTIAL/GARAGE
Application Number: BRES2017-0295
Property Address: 77640 CALLE ARROBA
APN: 774123025
Application Description: FARRINGTON RESIDENCE / GARAGE ADDITION
Property Zoning:
Application Valuation:
Applicant:
PAUL FARRINGTON
77640 CALLE ARROBA NOV 3.0 2017
LA QUINTA, CA 92253.
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of.perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
Q� ji -h, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
Cs owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Con ractors' State License Law.).
f�am exempt under Sec. B.&P.C. for this reason
l �36 ZO /-7 towner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
VOICE (760) 777-7125
FAX (760) 717-7011
INSPECTIONS (760) 777-7153
Date: 11/30/2017
Owner:
PAUL FARRINGTON
77640 CALLE C.RROBA
LA QUINTA, CA 92253
Contractor:
OWNER / BUILDER
Llc. No.:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one if the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
1 have and will maintain workers' oompensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carri Policy Number: _
==1—n ertify that in the performance olthe work for which this permit is issued, I
shall -not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 3Q ZO/7 Applicant' -
WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL, .
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,D)O). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FCM IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this applcation is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City :)f La Quinta, its officers, agents, and
employees for any act or omission related to tie work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordirances and state laws relating to building
construction, and hereby authorize representatives of this cit o en er the above-
mentioned property for inspection purposes.
Dater /�3020r/ !Signature (Applicant ciAge
C
Date: 11/30/2017
Application Number: _:
BRES2017-0295
Owner:
Property'Addiess'~""' '"'77640
CALLE ARROBA
PAUL FARRINGTON
APN:
774123025
77640 CALLE ARROBA
Application Description:
FARRINGTON RESIDENCE /GARAGE ADDITION
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
Applicant:
Contractor:
PAUL FARRINGTON
OWNER / BUILDER
77640 CALLE ARROBA
LA QUINTA, CA 92253
Llc. No.:
Detail: GARAGE ADDITION OF 375 SF. PER 2016 CALIFORNIA BUILDING CODE
:;...:DESCRIPTION
ACCOUNTTY
QTY
AMOUNT
AMOUNT
101-0000-42600
101-0000-42600
($47.98)
DESCRIPTION
ACCOUNT •
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$19.12
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$47.98
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.72
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$131.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600 j
0
1 $184.13
Total Paid for ADDITION: $353.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT -
QTY
AMOUNT
HOURLY CHARGE - YES PRINCIPAL/STRUCTURAL ENGINEER
101-0000-42600
1
$150.00
Total Paid for -BLDG CITY STAFF - PER HOUR:- $160.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
AMOUNT
101-000042600
101-0000-42600
($26.01)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
QTY
101-0000-42600
RECORDS MANAGEMENT FEE
($26.01)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.01
Total Paid for ELECTRICAL: '$0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PLAN CHECK DEPOSIT - GARAGE/CARPORT
101-0000-42600
1
$100.00
Total Paid for PLAN CHECK DEPOSIT - GARAGE/CARPORT: $100.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
11
Bing
�J _
J
00 `
-
City of La Quinta
Building & Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit*
1�
Project Address:
�1 Yl G'4 0 I Lc_
f ry Inr.`
Owner's e:
roc-( c. F�J fLtZ � �tilC. 1�1
A.P. Number
Address:
Legal Description:
City, ST, Zip:
Contractor:
Ou�V���
Telephone:
%$
Address:
Project Dcscrip oil:
City, ST, Zip:
f elephone: 76 O S 79
:mail: 7 ,�
090
r
City, ST, Zip:
'Telephone:
struction Type:
Occupancy:
Alter Repair Demo
!State Lie. #: . Type
(Estimated
New
Add'n
Name of Contact:
t:
#Stories
# Units:
'Telephone of Contact:
Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Req'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check Submitted
Item
Amount
Structural Calcs
Reviewed, ready for corrections
Plan Check Deposit:
Truss Calcs
Called Contact Person
Plan Check Balance:
Title 24 Calcs
Plans Picked Up
Construction:
Flood Plain Plan
Plans Resubmitted
Mechanical:
Grading Plan
2nd Rev, Ready for corrections /
Electrical:
Subcontractor List
Called Contact Person
Plumbing:
Grant Deed
Plans Picked Up
S.M.I.
HOA Approval
Plans Resubmitted
Grading
IN-HOUSE
3rd Rev, Ready for corrections /
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Apps
Date of permit issue
School Fees
Total Permit Fees
Tw9r/ 4 .('F'auGifa
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder- We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior. approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signs you understand or verify this information.
I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
uilding permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility,
. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand.that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
� 'l understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
AL . understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
A—&-runderstand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
risk,
f understand under California Contractors' State License Law, an Owner -Builder who builds single-family zesidential
structures cannot legally build them with the intent to offer them for sAle, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
�I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
9: I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
�. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally and financially res onsible for proposed construction activity at the following address:
11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders as.well as employers.
./-- -12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
'"leave provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only rernedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner Date: // 3 c7 L o / 7
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -.builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature.
Property Owner's Signature: Date:
YOUNG
ENGINEEFZING ,' Country: Palm Desert,
Letter of Transmittal
To: City of La Quinta Today's Date: 10/20/17
78-495 Calle Tampico City Due Date: 10/24/17
La Quinta, CA 92253 Project Address: 77640 CALLE ARROBA
Attn: MARY
Plan Check #: BRES2017-0295
Submittal: 0
15t
❑ 4th
❑
2nd
❑ 5th
❑
3td
❑ Other:
We are forwarding:
El By Messenger
❑
By Mail (Fed Ex or UPS)
❑ Your Pickup
Includes:
Descriptions:
Includes: # Of
Descriptions:
Copies:
❑
Structural Plans
❑
Revised Struct. Plans
❑
Structural Calculations
❑
Revised Struct. Calcs
❑
Truss Calcs
❑
Revised Truss Calcs
❑
Soils Report - Update
❑
Revised Soils Report
❑
Structural P/C Responses
14
Approved Structural Plans
/ Comments
1
❑
Redlined Structural Plans
0 j
Approved Structural Calcs
❑
Redlined Structural Calcs
El
Approved Truss Calcs
❑
Redlined Truss Calcs
❑
Approved Soils Report
❑
Redlined Soils Reports
❑
Other:
Comments: Structural content is approvable.
103
LE llr�, i�� 0
Transit Per Diem=�
r ��
Admin Time = 0.25
hrs.
Structural Engineer/Principal Review Time = 1.0
hrs.
Plan Review Engineer Time =
0.0 hrs.
U11 Y OF
LOUMM
UNITY DEVELOPMENT
This Material Sent for:
❑
Your Files
El
Per Your Request
❑
Your Review
❑
Approval
❑
Checking
❑
At the request of:
Other: ❑
By: Bronz Young
Office: 0 (760) 772-5107
Other: El LOPCOVALUENGR.COM
CITY OF LA QUINTA SUB -CONTRACTOR. LIST
JOB ADORE55_. 7rr Sr 1IC rr� � _-•— PERMIT NUMBER 0 W N E R j i� .rW�_r 0�6 -C "BUILDER
This form Shall be asted atl the ob.W1 h the Bullcliac� InspeCtiosl Card at all Times in a gortspicuous pl-lce. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencernent of work. Failure to comply will result in a stoppage of work and/or the voidance
of buildinrl permit_ For each applicable trade, all information requested below must be corripfeted by sipplicant. - "On File" is not an acceptable response.
r . .. � .. c i11YiCF15aLiC11 City Bir
..-, - ,... -:--... -t>•�C Dr:,:. -:' .. iL..Vfit3lLtar 5 L1C['_nSC_;:
OF�[Cr5 C [
I Cell t ;-:•• ,
w
�f,:li1C../�.�Ia,=51(4Ca�lUl1 --�----� �� • - ....`• ..... -.
Company Name Classification License Number Exp. Date Carrier Name Policy Number Exp. Date License Number Exp. Date
(e.g. A, B, C-8) (xxxxxx) (xx/xx/xx) (e.g_ State Fund, CalComp) (Format Varies) (xxlxx/xx) (xxxx) lxx/xxlxx)
EARTHWORK IG:-12).:` —
CONCRETE
FrtAMING (G-5j r_
STFtUCi'. STEEL (C-151)::•.:-
11 ASDNRY (C- 9)
PLUMBING (C-3G) ..' _
I_A_fH_PLASTER (C-:15,1 ' ,
❑F-1YINALL (C-rJ).
!-(VAC (C-2b):
ELFb-All CAL (C=10) . S �..-_ �j ac; ( a---
R. 0 0 H N G (C-
Si IFLi META(_ (C-43)
F.L0af, N6 (C-15):
GL_A7ING (C-'I7);:.`:
7NSULATION (C 7) _
SEWAGE DISP_ [C9.42)
PAINTINd
CI-(i11NIIC IIL.L•(C-.a1)
FENCING IG. 131
lAt,l r75GJ'1PING .(C-?.7)
WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN
a
Farmington garage.wsw
COMPANY AND PROJECT INFORMATION
fair_ Architecture Inc.
Bear Lake. CA
neeir-u cerriur_c
Woodworks® Shearwalls 11.1
Project Information
Project
Residence
D
Sep. 20, 2017 11:49:24
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT 1
RECEIVE
OCT 12 2017
Design Code Wind Standard Seismic Standard
IBC 2015/AWC SDPWS 2015 ASCE 7-10 Directional (All heights) ASCE 7-10
Load Combinations
Building Code Capacity Modification
For Design (ASD) For Deflection (Strength)
Wind Seismic
0.70 Seismic 1.00 Seismic
1.15 1.15
0.60 Wind 1.00 Wind
Service Conditions and Load Duration
Max Shearwall Offset [ft]
Duration Temperature Moisture Content
Plan Elevation
Factor Range Fabrication Service
(within story) (between stories)
1.60 T<=100F 19% <=19$ 10% <-19%
0.50 -
Maximum Height -to -width Ratio
Wood panels Fiberboard Lumber Gypsum
Wind Seismic Wind Seismic Blocked Unblocked
3.5 3.5 - - - -
Ignore non -wood -panel shear resistance contribution...
Collector forces based on...
Wind Seismic
Hold-downs Applied loads
when comb' d w/ wood panels Always
Drag struts Applied loads
Shearwall Relative Rigidity: Deflection -based stiffness of wall segments
Perforated shearwall Co factor: SDPWS Equation 4. 3-5
Non -identical materials and construction on the shearline: Not allowed
Deflection Equation: 3-term from SDPWS 4.2-1
Drift limit for wind design: 1 / 500 story height
SITE INFORMATION
Wind
ASCE 7-10
Directional (All heights)
Design Wind Speed
125 mph
Serviceability Wind Speed
125 mph
Exposure
Exposure C
Enclosure
Partly Enclosed
Min Wind Loads: Walls
16 psf.
Roofs
8 psf
Topographic Information [ft]
Shape
Height Length
Site Location: -
Slev: Oft Avg
Air density: 0.0765 lb/cu ft
Rigid building
- Static analysis
Case 2
E-W loads NS loads
Eccentricity (%)
15 15
Loaded at
75%
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE i t ll �f� BY '
Seismic
ASCF 'l-10 12.8
Equivalent Lateral
Force Procedure
Risk Category
Category II
- All others
Structure Type
Regular
Building System
Bearing Wall
Design Category
D
Site Class
D
Spectral Response Acceleration
S1: 0. 600g
Ss: ''_ . 500g
Fundamental Period
E-W
NS
T Used
0.166s
0.166s
Approximate Ta
0.166s
0 .166s
Maximum T
0.233s
0.233s
Response Factor R
6.50
6.50
Fa: 1 • 00
Fv: 1. 50
� _•- A3
9/20/2017 Design Maps Summary Report
SUMS Design Maps Summary Report
a User —Specified Input
Report Title FARMINGTON
Wed September 20, 2017 16:56:17 t TC
Building Code Reference Document ASCE 41-13 Retrofit Standard, BSE-2N
(which utilizes USG.S hazard data available in 2003)
Site Coordinates 33.6580N, 116.31008°W
Site Soil Classification Site Class D - "Stiff Soil"
,,lIV
} Raet[lui _
;7.� •• .- Midge
Palm Desert IncGv+ -
.Coachella
r.
4-
OIr
�..
r r�yrs! .1F
USGS—Provided Output
SS,BSE-2N 1.500 g SXS,BSE-2N 1.500 g
S1,BSE-2N 0.600 g SX1,BSE-2N 0.900 9
;1Lr:L oo a a. Sp. ek::rum
�:rpp; � QrsJ
�xyuel:fle;>:cchran �
ttq!t! tiItpert
'lrlrrl'a
hlthougn this information Is a product of the U.S. Geologicai Survey, we providr. no :,,arrant/, expressed or implied, as to the
accuracy of ;he data curtained therein. This tool is not a substitute for te-hrical subject -matter knowledge.
https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=33.657997493219334&longitude=-116.31008092339432&s. 1 /1
WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24 I
Structural Data
STORY INFORMATION
Hold-down
Story Floor/Ceiling wall Length subject to Bolt
Elev Ift] Depth in Height [ft] shrinkage [in] length [in]
Ceiling 14.04 0.0
Level 0.54 0.5 13.50 4.3 5.0
Foundation 0.50
BLOCK and ROOF INFORMATION
Block
Dimensions tt
Face
Tye
Root Panels
Sloe
overhang
Block 1
1 Story
N-S Ridge
Location X,Y =
0.00
0.00
North
Gable
90.0
2.00
Extent X,Y =
23.00
32.00
South
Gable
90.0
2.00
Ridge X Location, Offset
11.50
0.00
East
Side
30,0
2.00
Ridge Elevation. Height
20.68
6.64
West
side
30.0
2.00
2
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
SHEATHING MATERIALS by WALL GROUP
Sheathing Fasteners Apply
Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes
in in Ibslin I in in
7 Ext Struct I OSB 32/16 15/32 3 Vert 835001 8d Nail N 2 12 Y 2
2 Ext Struct Sh OSB 32/16 15132 - 3 Vert 83500 8d Nail N 3 12 Y 2
3 Ext Struct Sh OSB 32116 15/32 - 3 Vert 83500 8d Nail N 4 12 Y 2
Legend:
Grp — Wall Design Group number, used to reference wall in other tables
Sun`— Exterior or interior surface when applied to exterior wall
Ratng— Span rating, see SDPWS Table C4.2.2.2C
Thick— Nominal panel thickness
GU - Gypsum underlay thickness
Ply — Number of plies (or layers) in construction of plywood sheets
Or— Orientation of longer dimension of sheathing panels
Gvty — Shear stiffness in lb/n. of depth from SDPWS Tables C4.2.2A-B
Type — Fastener type from SDPWS Tables 4.3A-D: Nail — common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB,
plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail, Casing — casing nail,• Roof — roofing nail; Screw — drywall screw
Size - Common, box, and casing nails: refer to SDPWS Table Al (casing sizes = box sizes).
Gauges: 1 i ga = 0.120" x 1-314" (gypsum sheathing, 25/32" fiberboard), 1-112" (lath 8 plaster, 112" fiberboard); 13 ga plasterboard = 0.92" x 1-18".
Cooler or gypsum wallboard nail: 5d = .086"x 1-5W,- 6d = .092"x 1-78 8d = .113"x 2-3/8"; 6/8d = 6d base ply, 8d face ply for 2-ply GWB.
Drywall screws: No. 6, 1-1/4" long.
518" gypsum sheathing can also use 6d cooler or GWB nail
Df— Deformed nails ( threaded or spiral), with increased withdrawal capacity
Eg — Panel edge fastener spacing
Fd — Field spacing interior to panels
Bk — Sheathing is nailed to blocking at all panel edges; Y(es) or N(o)
Apply Notes — Notes below table legend which apply to sheathing side
Notes:
2. Framing at adjoining panel edges must be 3" nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4
FRAMING MATERIALS and STANDARD WALL by WALL GROUP
Species Grade
D.Fir-L No.2
D.Fir-L No.2
D.Fir-L No.2
b
d
Spc
in
in
in
3.50
5.50
16
3.50
5.50
16
3 5n
5 5n
16
Legend:
Wall Grp — Wall Design Group
b — Stud breadth (thickness)
d — Stud depth (width)
Spcg — Maximum on -centre spacing of studs for design, actual spacing may be less.
SG — Speck gravity
E— Modulus of elasticity
Standard Wall - Standard wall designed as group.
SG
E
Stanaara
psi"6
_
0.50
1.50
E
0.50
1.60
C
n.5n
1.60
B
Notes:
Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs.
3
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
SHEARLINE. WALL and OPENING DIMENSIONS
North -south
Type
wall
Location
Extent [ft]
Length
FHS
Aspect
Height
Shearlines
Group
X ft
Start End
ft
ft
Ratio
IN
Line 1
Level 1
Line 1
3
0.00
0.00 32.00
32.00
29.00
-
13.50
wall 1-1
Seg
3
0.00
0;00 32.00
32.00
29.00
-
-
Segment 1
-
-
0.00 24.00
24.00
-
0..56
-
opening 1
-
-
24.00 27.00
3.00
-
-
7.00
Segment 2
-
-
27.00 32.00
5.00
-
2.70
-
Line 2
Lovell
Line 2
3
23.00
0.00 32.00
32:00
29.00
-
13.50
Wall 7.-1
Seg
3
23.00
0.00 32.00
32.00
29.00
--
-
Segment 1
-
-
0.00 24.00
24.00
-
0.56
-
opening 1
-
-
24:.00 27.00
3.00
-
7.00
Segment 2
-
-
27..00 32.00
5.00
-
2.10
-
East -west
Type
Wall
Location
Extent [ft]
Length
FHS
Aspect
Height
Shearlines
Group
Y
Start End
IN
Ratio
Line A
Lovell
Line A
1
0.00
0.00 23,00
23.00
8.00
-
13.50
Wall A-1
Seg
1
0.00
0.00 23.00
23.00
8.00
-
-
Segment 1
-
-
0.00 4.00
4.00
-
3.38
-
Opening 1
-
-
4.00 19.00
15.00
-
-
12.00
Segment 2
-
-
19.00 23.00
4.00
-
3.38
-
Line B
Level 1
Line B
Seg
2
32.00
0.00 23.00
23.00
23.00
-
13.50
Wall B-1
Seg
2
32.00
0.00 23.00
23.00
23.00
0.59
=
Legend:
Type - Seg = segmented, Prf = perforated, NSW = non-shearwall
Location - Dimension perpendicular to wall
FHS - Length of full -height sheathing used to resist shear force. For perforated walls, it is based on the factored segments Li defined in SDPWS 4.3.4.3
Aspect Ratio - Ratio of wall height to segment length (hlbs)
Wall Group - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall
4
WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
Loads
WIND SHFAR LOADS (as PntPrPd nr onriw-Atnrtl
Level
Block
F
Element
Load
Case
Wnd
Dir
Surf
Dir
Prof
Location [ft]
start End
Magnitude
[lbs,plf,psf]
Start
End
Trib
Ht
ft
Block 1
W
Roof
Min
W->E
Wind
Line
-2.00
34.00
31.2
Block 1
W
Roof
1
W->E
Wind
Line
-2.00
34.00
39.4
Block. 1
W
Wall
Min
W->E
Wind
mine
0.00
32.00
54.0
Block 1
W
Wall
1
W->E
Wind
Line
0.00
32.00
132.5
Block 1
E
Roof
Min
W->E
Lee
Line
-2.00
34.00
31.2
Block 1
E
Roof
1
W->E
Lee
Line
-2.00
34.00
118.3
Block '_
E
Wall
1
W->E
Lee
Line
0.00
32.00
85.4
Block 1
E
Wall
Min
W->E
Lee
Line
0.00
32.00
54.0
Block 1
W
Roof
1
E->W
Lee
Line
-2.00
34.00
118.3
Block 1
W
Roof
Min
E->W
lee
Line
-2.00
34.00
31.2
Block 1
W
Wall
I
E->W
Lee
Line
0.00
32.00
85.4
Block 1
W
Wall
Min
E->W
Lee
Line
0.00
32.00
54.0
Block 1
E
Roof
1
E->W
Wind
Lire
-2.00
34.00
39.4
Block 1
E
Roof
Min
E->W
Wind
Line
-2.00
34.00
31.2
Block 1
E
Wall
Min •
E->W
Wind
Line
0.00
32.00
54.0
Block 1
E
Wall
1
E->W
Wind
Line
0.00
32.00
132.5
Block 1
S
Wall
14in
S->N
Wind
Line
0.00
23.00
54.0
Bloc: 1
S
L Gable
Min
S->N
Wind
Line
0.00
11.50
0.0
53.1
3ioc:t 1
S
Wall.
1
S->N
Wind
Lire
0.00
23.00
132.5
Bloc's 1
S
L Gable
1
S->N
Wind
Line
0.00
ii.50
0.0
132.7
Block 1
S
R Gable
1
S->N
Wind
Line
11.50
23.00
132.7
0.0
Block 1
S
R Gable
Min
S->N
Wind
Line
11.50
23.00
53.1
0.0
Block. 1
N
L Gable
1
S->N
Lee
Line
0.00
11.50
0.0
70.8
Block 1
N
Wall
"1
S->N
Lee
Line
0.00
23.00
72.0
Block 1
N
I. Gable
Min
S->N
Lee
Line
0.00
11.50
0.0
53.1
Block. 1
Pl
Wall
Min
S->N
Lee
Line
0.00
23.00
54.0
Block 1
N
R Gable
Min
S->N
Lee
Line
11.50
23.00
53.1
0.0
Block 1
N
R Gable
.1
S->N
Lee
Line
11.50
23.00
70.8
0.0
Block 1
S
Wall
Mir.
N->S
Lee
Line
0.00
23.00
54.0
Block 1
S
L Gable
Min
N->S
Lee
Line
0.00
11.50
0.0
53.1
Block 1
S
L Gable
1
N->S
Lee
Line
0.00
11.50
0.0
70.8
Block 1
S
Wall
1
N->S
wee
Line
0.00
23.00
72.0
Block 1
S
R Gable
Min
N->S
Lee
Line
11.50
23.00
53.1
0.0
Block 1
S
R Cable
1
N->S
Lee
Line
11.50
23.00
70.8
0.0
Block 1
fl
L Gable
Min
N->S
Wind
Line
0.00
11.50
0.0
53.1
Block 1
N
L Gable
1
N->S
Wind
Line
0.00
11.50
0.0
132.7
Block 1
N
Wall
Min
N->S
Wind
Line
0.00
23.00
54.0
Block 1
N
Wall
1
N->S
Wind
Line
0.00
23.00
132.5
Block 1
N
E Gable
Min
N->S
Wind
Line
11.50
23.00
53.1
0.0
Block 1
N
R Gable
1
N->S
Wind
Line
11.50
23.00
132.7
0.0
Legend:
Block - Block used in load generation
Accum. = loads from one block combined with another
Manual = user -entered loads (so no block)
F - Building face (north, south, east or west)
Element - Building surface on which loads generated or entered
Load Case - One of the following:
ASCE 7 All Heights: Case 1 or 2 from Fig 27.4-8 or minimum loads from 27.1.5
ASCE 7 Low-rise: Reference comer and Case A or B from Fig 28.4-1 or minimum loads from 28.4.4
Wind Dir- Direction of wind for loads with positive magnitude, also direction of MWFRS.
Surf Dir - Windward or leeward side of the building for loads in given direction
Prof- Profile (distribution)
Location - Start and end points on building element
Magnitude - Start = intensity of uniform and point loads or leftmost intensity of trapezoidal load, End = right intensity of trap load
Trib Ht - Tributary height of area loads only
Notes:
All loads entered by the user or generated by program are specified (unfactored) Ioads.The program applies a load factor of 0.60 to wind loads before
distributing them to the sheadines.
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 201711:49:24
WIND C$C LOADS
Block
Building
Face
Wind
Direction
Level
Magnitude [pst]
Interior End Zone
Block 1
West
windward
1
49.1
58.0
Block 1
East
Leeward
1
49.1
58.0
Block 1
West
Leeward
1.
49.1
58.0
Block 1
East
Windward
1
49.1
58.0
Block 1
South
Windward
1
49.1
58.0
Block 1
North
Leeward
1
49.1
59.0
Block 1
South
Leeward
1
49.1
58.0
Block 1
North
windward
1
49.1
58.0
s
WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24 '
BUILDING MASSES
Level Magnitude Trib
Force Building Block Wall Profile Location [ft] [lbs,plf,psf] Width
Dir Element Line Start End Start End IftL
E-W
Roof
Block 1
1
Line
-2.00
34.00
135.0
135.0
E-W
Roof
Block 1
2
Line
-2.00
34.00
135.0
135.0
N-S
Roof
Block 1
A
Line
-2.00
25.00
180.0
180.0
N-S
Roof
Block 1
B
Line
-2.00
25.00
180.0
180.0
N-S
L Gable
Block 1
A
Line
0.00
11.50
93.0
0.0
N-S
R Gable
Block 7
A
Line
11.50
23.00
0.0
93.0
N-S
R Gable
Block 1
B
Line
0.00
11,50
93.0
0.0
N-S
L Gable
Block 1
B
Line
11.50
23.00
0.0
93.0
Both
Wall 1-1
n/a
1
Line
0.00
32.00
94.5
94.5
Both
Wall 2-1
n/a
2
Line
0.00
32.00
94.5
94.5
Both
Wall A-1
n/a
A
Line
0.00
23.00
94:5
94.5
Both
Wall B-1
n/a
B
Line
0.00
23.00
94.5
94.5
Legend -
Force Dir - Direction in which the mass is used for seismic load generation, E-W, N-S, or Both
Building element - Roof, gable and, wall or floor area used to generate mass, wall line for user -applied masses, Floor F# - refer to Plan View for floor area
number
Wall line - Sheartine that equivalent line load is assigned to
Location - Start and end points of equivalent line load on wall line
Trib Width. - Tributary width; for user applied area loads only
7
WoodWorks® Shearwalls
Farmington garage.wsw Sep. 20, 2017 11:49:24
SEISMIC LOADS
Level i
Force
Dir
Profile
Location Ift]
Start End
Mag;1bs,pIf,psf]
Start
E-W
Line
-2.00
0.00
41.5
41.5
E-W
Point
0.00
0.00
499
499
E-W
Line
0.00
32.00
70.6
70.6
E-W
Point
32.00
32.00
499
499
E-W
Line
32.00
34.00
41.5
41.5
N-S
Line
-2.00
0.00
55.4
55.4
N-S
Point
0.00
0.00
465
465
N-S
Line
0.00
11.50
84.5
113.1
N-S
Line
11,50
23.00
113.1
84.5
N-S
Point
23.00
23.00
465
465
N-S
Line
23.00
25.00
55.4
55.4
Legend
Loads in table can be accumulation of loads from several building masses, so they do not correspond with a particular building element.
Location - Start and end of load in direction perpendicular to seismic force direction
Notes:
All loads entered by the user or generated by program are specified (unfactored) Ioads.The program applies a load factor of 0.70 and redundancy factor to
seismic loads before distributing them to the shearlines.
8
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
Design Summary
SHEARWALL DESIGN
Wind Shear Loads, Flexible Diaphragm
All shearwalls have sufficient design capacity
Components and Cladding Wind Loads, Out -of -plane Sheathing
All shearwalls have sufficient design capacity.
Components and Cladding Wind Loads, Nail Withdrawal
All shearwalls have sufficient design capacity.
Seismic Loads, Flexible Diaphragm
All shearwalls have sufficient design capacity.
HOLDDOWN DESIGN
Wind Loads, Flexible Diaphragm
All hold-downs have sufficient design capacity.
Seismic Loads, Flexible Diaphragm
All hold-downs have sufficient design capacity.
This Design Summary does not include failures that occur due to excessive story drift from ASCE 7 CC1.2 (wind) or 12.12 (seismic).
Refer to Story Drift table in this report to verify this design criterion.
Refer to the Deflection table for possible issues regarding fastener s?fppage (SDPWS Table C4.2.2D).
Woodworks® ShearWalls Farmington garage.wsw Sep. 20, 2017 11:49:24
- 17---
- __
Flexible Diaphragm Wind Design
ASCE 7 Directional (All Heights) Loads
SHEAR RESULTS
N-S
W
For
ASD Shear Force [plf]
Asp -Cub
Allowable
Shear [plf]
Res p.
Shearlines
G
Dir
v Max V
Ibs
Int Ext Int
Ext Co
C Cmb
V [IN
Ratio
Line 1
Level 1
Lnl, Lev1
-
Both
- -
2113
- - -
612 -
17475
17475
-
Wall 1-1
3^
Both
- -
2113
- 1.0 -
1.0 -
612
612
612
14683
0.14
Seg. 1
-
Both
88.0 -
2113
0
-
- -
-
558
558
2791
0.00
Seg. 2
-
Both
0.0 -
.91
Line 2
2113
- - -
612 -
-
17475
-
Ln2, Levl
-
Both
- -
-
2113
- 1.0 -
612
-
17475
-
Wall 2-1
3^
Both
-
2113
- i.0 -
612 -
612
14663
0.14
Seg. 1
-
Both
88.0 -
0
- -
558
558
2791
0.00
Seg. 2
-
Both
0.0 -
.91
E-W
W
Far
ASD Shear Force [pifj
Asp -Cub
Allowable Shear [plf]
Resp.
Ratio
Shearlines
G
Dir
v vmax VnInt
Ext in t
Ext Co
C Cmb
V lbs
Line A
Level
LnA, Levl
-
Both
- -
- -
1175 _
-
-
7786
7786
-
Wall A-1
1^Both
- -
- 1.0 -
-
1175 -
973
973
3893
0.49
Seg. 1
-
W->E
474.4 -
1804
- .83
- -
_
9"/3
973
3893
0.46
2
-
-
E->W
W->E
451.1 -
474.4 -
1898
.83
- .83
973 -
973
3893
0.41
Seg.
-
E->W
497.7 -
1991
-
- .83
973
973
3893
0.51
Line B
LnB, Levl
2^
Both
165.0 -
3795
- 1.0 -
789 -
789
18145
0.21
Legend:
W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^"means that this wall is critics! for
all walls in the Standard Wall group.
For Dir - Direction of wind force along shearhine.
v - Design shear force on segment = ASD factored shear farce per unit FHS
vmax - Collector shear force for perforated walls as per SDPWS eqn. 4.3-8 = VIFHS/Co. Full height sheathing (FHS) factored for narrow segments as per
4-3.4.3
V - ASD factored shear force. For shearline.- total she adine force. For wall: total of all segments on wall. For segment.- force on segment
Asp/Cub -For wall: Unblocked structural wood panel factor Cub. from SDPWS 4.3.3.2. For segment: Aspect Ratio Factor from SDPWS 4.3.4.2-
In( -Unit shear capacity of interior sheathing, Fxt -Unit shear capacity of exterior sheathing. For wail: Unfactored. For segment Include Cub factor and
aspect ratio adjustments.
Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5.
C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness -based using SDPWS 4.3-3.
Cmb - Combined interior and exterior unit shear capacity including perforated wail factor Co.
V- Total factored shear capacity of shearfine, wall or segment.
Crit Resp -Response ratio = vXmb = design shear forcelunit shear capacity. "S" indicates that the wind design criterior was critical in selecting wall.
Notes:
Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4.
Allowable shear values have been reduced to 115% of published values.
10
Woodworks® Shearwalls
un! n nnWu ncQlr=- J rAnv:hln winri A..in"I
Farmington garage.wsw
Sep. 20, 2017 11:49:24
Level 1
Line-
Wall
Posit'n
Location [ft]
X Y
Load
Case
Tensile ASD
Holddown Force [lbs]
Shear Dead Uplift
Cmb'd
Hold-downfibs]
Cap
Crit
Res .
Line 1
-'?
L End
0.00
0.12
1
1201
1201
HDU5-5 2-PIII' 56J5
l-Ar,0.21
?-1
L op 1
0.00
23.88
1
1201
1201
-SDS2.
5645
0.21
Line 2
2-1
L End
23.00
0.1.2
1
1201
1201
HDU5-SDS2. X
5645
0.21
2-1
L Op 1
23.00
23.88
1
1201
1201
HL)U5-SDS2.
5645
0.21
Line A
✓
A-1
L End
0.12
0.00
1
739
7397
HDQB 6X.6
"9230
0.80
A-1
L On 1
3.88
0.00
1
70 Ri=�
�/50 5
7U34
7397
HDQS 626 !J i�
HDQB 6X6
9230
9230
0.76
0.80
A-1
R op 1
19.12
0.00
1
7 37
/�
A-1
R End
22.88
0.00
1
761
7761
HDQB 6X6
'9230
0.84
Line B
B-1
L End
0.12
32.00
1
2809
2809
F?TiU532. F16jC/
HS7H�°�-SDS2. 40
5C' e
4);r?0. 50
0.50
B-1
R End
22.88
32.00
1
2,309
2809
JK45.
Legend:
Line -Walt
At wall or opening - Shearline and wall number At vertical element - Shearfine
Posit'n - Position of stud that hold-down is attached to:
V Elem - Vertical element. column or strengthened studs required where not at wall end or opening
L or R End - At left or right wall end
L or R Op n - At left or right side of opening n
Location - Co-ordinates in Plan View
Load Case - Results are for critical load case:
ASCE 7 All Heights: Case 1 or 2 from Fig. 27.4-8
ASCE 7 Low-rise: Windward comer(s) and Case A or B from Fig. 28.4-1
ASCE 7 Minimum loads (27.1.5 / 28.4.4)
Hold-down Forces:
Shear- Wind shear overturning component, based on shearline force, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used.
Dead - Dead load resisting component, factored forASD by 0.60
Uplift - Uplift wind load component factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used.
Cmb'd - Sum of ASD factored overturning, dead and uplift forces. May also include the uplift force t for perforated walls from SDPWS 4.3.6.2.1 when
openings are staggered.
Hold-down - Device used from hold-down database
Cap - Allowable ASD tension load
Crft. Resp. - Critical Response = Combined ASD force /Allowable ASD tension load
Notes:
AWARNING - This hold-down does not have design capacities for the thickness of end studs selected, so additional jack studs or blocking required
Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li• used to calculate tension force T for perforated walls from
SDPWS 4.3-9.
11
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 201711:49:24
UKAG S 1 KU 1 rVK"O ti18XIDTe Wino
Level 1
Line-
Position on Wall
Wall
or Opening
Line 1
1-1
Left Opening 1
Line 2
2-1
Left Opening 1
Line A
A-1
Left Opening 1
A-1
Right Opening 1
Drag Strut
Location [ft]
Load
Force pbs]
X Y
Case
—> <-
0.00 24.00
1
528 528
23.00 24.00
1
528 528
4.00 0,00
1
1238 1144
19.00 0.00
1
1238 1331
Line -Wall - Sheartine and wall number
Position.. - Side of opening or wall end that drag strut is attached to
Location - Co-ordinates in Plan View
Load Case - Results are for critical load case:
ASCE 7 All heights Case 1 or
ASCE 7 Low-rise comer, Case A or B
Dreg strut Force - Axial force in transfer elements at openings and gaps in walls along shearline.
Based on ASD factored shearline force (vmax from 4.3.6.4.1.1 for pertbrated walls)
-> Due to sheartine force in the west -to -east or south -to -north direction
<- Due to shearline force in the east -to -west or north -to -south direction
12
C
WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
MWFRS DEFLECTION (flexible wind design)
ThPen riafiarrrnnr wo imgri to rigtarminr fnr fnrr.P rlictrfhirtion
Wall,
segment
W
Gp
Dir
Srf
v
If
b
ft
In
ft
Bending
A Defl
s .in in
Ga
kips/
in
Nail slip
Vn en
Ibs in
Shear
Defl
in
Hold
Defl
in
Total
Defl
in
Levels
Line 1
1-1,1
3
Both
Ext
88.0
24.00
13.50
19.3
.002
15.6
204
043
.076
0.08
0.16
1-1,2
S->N
Ext
0.0
5.00
13..50
19.3
.000
15.6
204
.043
.000
0.00
0.00
N->S
Ext
M
5- 00
13.50
57.8
.000
15.6
204
.043
.000
0.00
0.00
Line 2
2-1,1
3
Both
Ext
88.0
24.00
13.50
19.3
.002
15.6
204
.043
.076
0.08
0.16
2-1,2
S->N
Ext
0.0
5.00
13.50
19.3
.000
15.6
204
.043
.000
0.00
0.00
N->S
Ext
0.0
5.00
13.50
57.8
.000
15.6
204
.043
.000
0.00
0.00
Line A
A-1,1
1
W->E
East
474.4
4.00
13.50
19.3
.076
31.2
196
.031
.205
0.65
0.93
E->W
Ext
451- 1.
4.00
13.50
19.3
.072
31.2
196
.031
.195
0.64
0.90
A-1,2
W->E
ExL
474.4
4.00
13.50
19.3
.076
31.2
196
.031
.205
0.65
0.93
E->W
Ext
497.7
4.00
13.50
57.8
.027
31.2
196
.031
.216
0.66
0.90
Line B
B-1
2
Both
Ext
165.0
23.00
13.50
19.3
.005
20.6
197
_039
.108
0.10
0.21
Legend:
Wall, segment - Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Sheartine B
W Gp - Wall design group defined in Sheathing and Materials tables, where it shows associated Standard Wall.
Dir- Force direction
Srf- Wall surface, interior or exterior for perimeter walls, 1 or 2 for interior partitions
v - ASD shear force per unit distance on wall segment. For perforated walls, vmax from SDPWS 4.3-9 is used, as per 4.3.2.1
b - Width of wall segment between openings. Modified for perforated walls as per SDPWS 4.3.2.1
h - Wall height
Deli - Horizontal shearwall deflection due to given term:
Bending = 8vh^3 / EAb; A - Cross sectional area of segment end stud(s); E - stud mod. of elasticity in Framing Materials table
Shear = vh / 1000 Ga. Ga - vw / (vw / Gt + 0.75 en), from SDPWS Ex. C4.3.2-1; vw - ASD sheathing capacity; Gt - Shear stiffness from SDPWS
C4, 3.3.2, value is in Sheathing Materials table; en - Nail slip from SDPWS table C4.2.2D, Vn - Shear force per nail along panel edge using vw
Hold - Hold-down = da x h /b; refer to Hold-down Displacement table for components of da
Total deft = Deflection from bending + shear + hold-down, as per SDPWS C4.3.2-1
13
Woodworks® Shearwalls
Farmington garage.wsw Sep. 20, 2017 11:49:24
MWFRS HOLD-DOWN DISPLACEMENT (flexible wind design)
Thaca rticntaramanfc ary �earl In rtatPm�rnp rtPllnnfinnc fnr fnrr.P dishihution
Wall,
segment Dir
Hold-
down
uplift
force
Ibs
Elong / Disp
Manuf Add da
in in in
Slippage
Pf da
ibs in
Shrink
da
in
Crush+
Extra
in
Total
da
in
Hold
Defl
in
Level 1
Line 1
1-1,1 Both
HDU5-SDS
1201
.024 .000 0.02.4
- -
.076
0.04
0.14
0.08
1-1,2 S->N
HDU5-SDS
0
.000 .000 0.000
- -
.000
0.00
0.00
0.00
N->S
HDU5-SDS
0
.000 .000 0.000
-
.000
0.00
0.00
0.00
Line 2
2-1,1 Both
HDU5-SDS
1201
.024 .000 0.02.4
- -
.076
0.04
0.14
0.08
2-1,2 S->N
HDU5-SDS
0
.000 .000 0.000
- -
.000
0.00
0.00
0.00
N->S
HDU5-SDS
0
..000 .000 0.000
- w
.000
0:00
0.00
0.00
Line A
A-1,1 W->E
HDQ8 6X6
7397
.076 .000 0.076
- -
.076
0.04
0.19
0.65
E->Trl
HDQ8 6X6
7034
.072 .000 0.072
- -
.076
0:04
0.19
0.64
A-1,2 W->E
HDQ8 6X6
7397
.076 .000 0.076
- -
.076
0.04
0.19
0.65
R->W
HDQ8 6X6
7761
.080 .000 0.080
- -
.076
0,04
0.20
0-66
Line B
B-1 Both
HDU5-SDS
2809
.057 .000 0.057
- -
.076
0.04
1 0.17
1 0.10
Legend -
Wall, segment- Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Sheartine B
Dir- Force direction
Uplift face (P) Accumulated ASD hold-down tension force from overturning, dead and wind uplift For perforated walls, T from SDPWS 4.3-8 is used for
overturning
da - Vertical displacements due to the following components:
Elong/Disp - Elongation when slippage calculated separately; displacement when combined elongation/slippage used
Manuf - Using manufacturers value for anchor bolt length, or no bolt contribution for connector -only elongation.
Unless marked with " = (ASD uplit force /ASD hold-down capacity) x max ASD elongation or displacement
"- Maximum strength -level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing
the segment to draw less force due to lower than actual stiffness.
Add - Due to longer anchor bolt length than manufacturers value, or entire bolt length for connector -only elongation = PL / (Ab x Es );
Ab - bolt cross -sectional area;
Es = steel modulus = 29000000 psi;
L=Lb -Lh;
Lb = Total bolt length shown in Storey Information table;
Lh = Manufacturers anchor bolt length forgiven displacement/elongation from hold-down database.
Slippage - Due to vertical slippage of hold-down fasteners attached to studs) when not combined with elongation
Pf = ASD uplift force P / number of fasteners
Bolts: = Pfl (270,000 DA1.5) (NDS 11.3.6) ; D = bolt diameter
Nails: = en, from SDPWS Table C4.2.2D using Pf for Vn and values for Wood Structural Panel
Shrink- Wood shrinkage = 0.002 x (19% fabrication- 10% in-service moisture contents) x Ls
Ls = Perp_-to-grain length between fasteners subject to shrinkage, shown in Storey Information table
Crush + Extra - 0.04" wood crushing at compression end of wall segment plus extra displacement due to mis-cuts, gaps, etc.
Total da = Elong/Disp + Slippage + Shrink + Crush + Extra
Hold Deft- Horizontal deflection = h/b x da (4th term in the deflection equation SDPWS C4.3.2-1)
h = wall height; b = segment length between openings; h,b values in Deflection table
WARNING -At least some hold-downs do not have displacement values for the thickness of end studs selected, so additional jack studs or blocking
required.
14
i WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 2017 11:49:24
Out -of -plane Wind Design
COMPONENTS AND CLADDING by SHEARLINE
North -South
Sheathing [psf]
Fastener Withdrawal [Ibs]
Service Cond
Shearlines
Force Cap
Force/
Force
Cap Force/Cap
Factors
Line
Lev
Gr
End
Int End Int
TernMoist
1
3
34.8 56.2
_22p
0.62
46.4
39.3 103.9 0.45
0.38
1.00 1.00
2
1
34.8 56.2
0.62
46.4
39.3 103.9 0.45
0.38
1.00 1.00
East-West
Sheathing [psf]
Fastener Withdrawal [Ibs]
Service Cond
Shearlines
Force Cap
Force/
Force
Cap Force/Cap
Factors
Line
Lev
Grp
Cap
I End
Int End
Int
TernMoist
A
1
34.8 56.2
0.62
46.4
39.3 103.9 0.45
0.38
1.00 1.00
B
_
2
34.8 56.2
0.62
46.4
39.3 103.9 0.45
0.38
1.00 1.00
Legend:
Grp - Wall Design Group ( results for all design groups for rigid, flexible design listed for each wall)
Sheathing:
Force - C&C end zone exterior pressures using negative (suction) coefficient in ASCE 7 Figure 30.4-1 added to interior pressure using coefficients from
Table 26.11-1
Cap - Out -of -plane capacity of exterior sheathing from SDPWS Table 3.21, factored forASD and load duration, and assuming continuous over 2 spans
Fastener Withdrawal.
Force - Force tributary to each nail in end zone and interior zone
Cap - Factored withdrawal capacity of individual nail according to NDS 12.2-3
15
E
WoodWorks® Shearwalls
Farmington garage.wsw Sep. 20, 2017 11:49:24
Flexible Diaphragm Seismic Design
SEISMIC INFORMATION
Level Mass Area Story Shear jibs] Diaphragm Force Fpx jibs]
[lbal Ng. E-W N-S E-W N-S
1 22253 736.0 3424 3424 4451
All 22253 - 3424 3424 1 - -
Legend:
Building mass — Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12.
Stoney shear— Total unfactoned (strength -level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11.
Diaphragm fore Fpx - Unfactored force intended for diaphragm design from Eqn 12.10-1; used by Shearwalls only for drag strut forces, see 12.10.2.1
Exception 2.
Redundancy Factor p (rho):
E-W 1.00, N-S 1.00
Automatically calculated according to ASCE 7 12.3.4.2.
Vertical Earthquake Load Ev
Ev = 0.2 Sds D; Sds = 1,00; Ev = 0.200 D unfactored; 0.140 D factored; total dead load factor: 0.6 - 0.140 = 0.460 tension, 1.0 + 0.140 = 1.140 compression.
iP
WoodWorks® Shearwalls
Farmington garage.wsw
Sep. 20, 2017 11:49:24
SHEAR RESULTS !flexible seismic desionl
N-S
W
For
ASD Shear Force jplf]
Asp -Cub
Allowable Shear [plf]
Resp.
Shearlines
G I
Dir
v vmax Vfibs]
Int Ext Int
Ext Co
C Cmb
V Ibs
Ratio
Line 1
Level 1
Ln1, Levl
-
Both
- -
1198
- - -
437 -
-
12482
-
Wall 1-1
3
Both
- -
1198
- 1.0 -
437
-
12482
--
Seg. 1
-
Both
49.9
1198
- 1.0 -
437 -
437
10488
0.11
Seg. 2
Both
0.0 -
0
- .91 -.
399 -
399
1994
0.00
Line 2
1.n2, Levl
-
Both
- -
1198
- - -
437 -
-
12482
-
Wall 2-1
3
Both
-
1198
- 1.0 -
437 -
-
12482
-
Seg. 1
-
Both
49.9 -
1198
1.0 -
437 -
437
10488
0.11
Seg. 2
-
Both
0.0
0
- .91 -
399 -
399
1994
0-00
E-W
W
For
ASD Shear Force [plfJ
Asp -Cub
Allowable Shear [plf]
Resp.
Shearlines
Gp
Dir
v Max V ribsl
Int Ext Int
Ext Co
C Cmb
V Ibs
Ratio
Line A
Lovell
LnA, Levl
-
Both
- -
1198
- - -
840 -
-
5562
-
Wall A-1
1
Both
- -
1198
- 1.0 -
840 -
-
5562
Seg. 1
-
W->E
149.8 -
599
- .83 --
695 -
695
2781
0.22
-
E->W
144.1 -
577
- .83 -
695 -
695
2781
0.21
Seg. 2
-
W->E
149.8 -
599
- .83 -
695 -
695
2761
0.22
-
E->W
155.4 -
622
- .83 -
695 -
695
2781
0.22
Line B
LnB, Levl
2
Both
52.1 -
1198
- 1.0 -
564 -
564
12961
0.09
Legend
W Gp - Wall design group defined in Sheathing and Framing Materials tables,
all walls in the Standard Wall group.
For Dir- Direction of seismic force along sheartine.
v - Design shear force on segment = ASD factored shear force per unit FHS
vmax - Collector shear force for perforated walls as per SDPWS eqn. 4.3-8 =
where it shows associated Standard Wall. "A" means that this wall is critical for
V/FHS/Co. Full height sheathing (FHS) factored for narrow segments as per
4.3.4.3
V - ASD factored shear force. For sheartine: total sheartine force. For wall: total of all segments on wall. For segment: force on segment
Asp/Cub -For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment Aspect Ratio Factor from SDPWS 4.3.4.2.
Int - Unit shear capacity of interior sheathing, Ext - Unit shear capacity of exterior sheathing. For wall., Unfactored. For segment: Include Cub factor and
aspect ratio adjustments.
Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5.
C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness -based using SDPWS 4.3-3.
Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co.
V - Total factored shear capacity of sheartine, wall or segment
Crit Resp -Response ratio = v/Cmb = design shear force/unit shear capacity. 'W' indicates that the wind design criterior was critical in selecting wall.
Notes:
Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4.
Allowable shear values have been reduced to 115% of published values.
17
WoodWorks® Shearwalls Farmington garage.wsw
Sep. 20, 2017 11:49:24
HOLD-DOWN DESIGN (flexible seismic design)
Level 1
Line-
wall
Posifn
Location [ft]
X Y
Shear
Tensile ASD
Holddown Force [Ibs]
Dead Ev
ICap
Cmb'd
Hold-down
Jim
Crit
Res .
Line 1
1-1
L End
0.00
0.12
681
681
HDUS-SD52.
5645
0.12
1-1
L Op 1
0.00
23.88
681
681
HDU5-SDS2.
5645
0.12
Line 2
2-1
L End
2:3.00
0.12
681
681
HDU5-SDS2.
5645
0.12
2-1
L Op 1
23.00
23.99
681
681
HDU5-SD32.
5645
0.12
Line A
A-1
L End
0.12
0.00
2336
2336
HDQB 6X6
^9230
0.25
A-1
L Op 1
3.88
0.00
2248
2248
HDQ8 6X6
9230
0.24
A-1
R Op 1
19.12
0.00
2336
2336
HDQ8 6X6
9230
0.25
A-1
R End
22.88
0.00
2423
2423
HDQ8 6x6
^9230
0.26
Line B
B-1
L End
0.12
32.00
887
887
HDUS-SDS2.
5645
0.16
B-1
R End
22.88
32.00
887
BU
HDU5-SDS2.
5645
0.16
Legend:
Line -Wall:
At wall or opening- Shearfine and wall number
At vertical element - Shearline
Posit'n - Position of stud that hold-down is attached to:
V Elem - Vertical element. column or strengthened studs required where not at wall end or opening
L or R End - At left or right wall end
L or R Op n - At left or right side of opening n
Location - Co-ordinates in Plan View
Hold-down Forces:
Shear- Seismic shear overtuming component, factored for ASD by 0.7. For perforated walls, T from SDPWS 4.3-8 is used
Dead - Dead load resisting component, factored for ASD by 0.60
Ev - Vertical seismic load effect from ASCE 7 12.4.2.2 =-0.2Sds x ASD seismic factor x unfactored D = 0.233 x factored D. Refer to Seismic Information
table for more details.
Cmb d - Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t for perforated walls from SDPWS 4.3.6.2.1
when openings are staggered.
Hold-down - Device used from hold-down database
Cap - Allowable ASD tension load
Crit. Resp. - Critical Response = Combined ASD force/Allowable ASD tension load
Notes:
"WARNING - This hold-down does not have design capacities for the thickness of end studs selected, so additional jack studs or blocking required
Shear overturning force is horizontal seismic load effect Eh from ASCE 7 12.4.2.
Uses load combination 8 from ASCE 7 2.4.1 = 0.6D + 0.7 (Eh - Ev).
Anchor bolts must have minimum 0.229" x 3" x 3" steel plate washers, conforming to specifications in SDPWS 4.3.6.4.3 and 4.4.1.6.
Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from
SDPWS 4.3-9.
Shearwalls does not check for either plan or vertical structural irregularities.
18
WoodWorks® Shearwalls
Farmington garage.wsw Sep. 20, 201711:49:24
DRAG 5TRu1 FURGtb [riexiDle seismic oesign)
Level 1
Drag Strut
Line-
Position on Wall
Location [ft]
Force [Ibs]
wall
or Opening
X
Y
-> <--
Line 1
1-1
Left Opening 1
0.00
24.00
389 389
Line 2
2-1
Left Opening 1
23.00
24.00
389 389
Line A
A-1
Left Opening 1
4.00
0.00
508 479
A-1
Right Opening 1
19.00
0:00
508 537
Legend.
Line-Wali - Shearline and wall number
Position..: Side of opening or wall end that drag strut is attached to
Location - Co-ordinates in Plan View
Drag strut Force - Axial force in transfer elements at openings and gaps in walls along shearfine.
Based on ASD factored shearfine force derived from the greater of -
Diaphragm force Fpx from Eqn. 12.10-1 plus 25% irregularity increase (12.3.3.4)
Storey force Vx from Eqn 12.8-13
For perforated walls, shearfine force is vmax from 4.3.6.4.1.1. Includes redundancy factor rho.
-> Due to shearfine force in the west -to -east or south -to -north direction
<- Due to shearfine force in the east -to -west ornorth-to-south direction
19
�Y WoodWorks® Shearwalls
n CGI =d"NnU 10-1hi. enicmic Hl innl
Farmington garage.wsw
Sep. 20, 2017 11:49:24 -1
Wall,
segment
W
Gp
Dir
Srf
v
If
b
ft
h
ft
Bending
A Defl
s .in in
Ga
kips/
in
Nail slip
Vn en
Ibs in
Shear
Defl
in
Hold
Defl
in
Total
Defl
in
Level 1
Line 1
1-1,1
3
Both
Ext
71.3
24.00
13.50
19,3
.002
15.6
204
.043
.062
0.03
0.14
1-1,2
S->N
Ext
0.0
5.00
13.50
19.3
.000
15,.6
204
.043
.000
0.00
0.00
N->S
Ext
0.0
5.00
13.50
57.3
..000
15,6
204
.043
.000
0.00
0.00
Line 2
2-1,1
3
Both
Ext
71.3
24.00
13.50
19.3
.002
15.6
204
.043
.062
0.03
0.14
2-1,2
S->N
Ext
0.0
5.00
13.50
19.3
:000
15.6
204
.043
.000
0.00
0.00
N->S
Ext
0.0
5.00
13.50
57.3
.000
15.6
204
.043
.000
0.00
0.00
Line A
A-1,1
1
W->E
Eft
214.0
4.00
13.50
19.3
.034
31.2
196
.031
.093
0.50
0.63
E->'W
Ert
1 205.9
4.00
13.50
19.3
.033
31.2
196
.031
.029
0.50
0.62
A-1,2
W->E
Ext
214.0
4.00
13.50
.19.3
.034
31.2
196
.031
.093
0.50
0.63
E->W
Ext
222.0
4.00
13.50
57.3
.012
31.2
196
.031
.096
0.51
0.62.
Line B
B-1
2
Both
Ext
74.4
23.00
13.50
15.3
.002
20.6
197
.039
:049
1. 0,03
1 0,13
Legend:
Wall, segment - Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Shearline S
W Gp - Wall design group, refer to Sheathing and Framing Materials
Dir - Force direction
Srf- Wall surface, interior or exterior for perimeter walls, 1 or 2 for interior partitions
v - Unfactored (strength -level) shear force per unit distance on wall segment = ASD force/O. 70. Forperforated walls, vmax from SDPWS 4.3-9 is used, as
per 4.3.2.1
b - Width of wall segment between openings. Modified for perforated walls as per SDPWS 4.3.2.1
h - Wall height
Defl - Horizontal shearwall deflection due to given term:
Bending = 8vhA3 / EAb; A - Cross sectional area of segment end stud(s); E - stud mod. of elasticity in Framing Materials table
Shear = vh / 1000 Ga. Ga - 1.4 vs / (1.4 vs / Gt + 0.75 en) from SDPWS Ex. C4.3.2-1; vs - ASD sheathing capacity; Gt - Shear stiffness from SDPWS
C4.3.3.2, value is in Sheathing Materials table; en - Nail slip from SDPWS table C4.2.2D; Vn - Shear force per nail along panel edge using 1.4 vs
Hold - Hold-down = da x h /b; refer to Hold-down Displacement table for components of da
Total deft = Deflection from bending + shear + hold-down, as per SDPWS C4.3.2-1
20
WoodWorks® Shearwalls Farmington garage.wsw Sep. 20, 201711:49:24
Nr11 n-nowN rflRPl Or:1=MFNT fflarihla calsmir_ daainnl
Wall,
segment Dir
Hold-
down
Uplift
force
Ibs
Elong I Disp
Manuf Add da
in in in
Slippage
Pf da
Ibs in
Shrink
da
in
Crush+
Extra
in
Total
da
in
Hold
DO
In
Level 1
Line 1
1-1,1 Both
HDU5-SDS
973
.019 .000 0.019
- -
.076
0.04
0.14
0.08
1-1,2 S->N
HDU5-SDS
0
.000 .000 0.000
- -
.000
0.00
0.00
0.00
N->S
HDU5-SDS
0
...000 .000 0.000
- -
.000
0.00
0.00
0.00
Line 2
2-1,1 Both
HDU5-SDS
973
.019 .000 0.019
- -
.076
0.04
0.14
0.08
2-1,2 S->N
HDU5-SDS
0
.000 .000 0.000
- -
.000
0.00
0.00
0.00
N->S
HDU5-SDS
0
.000 .000 0.000
- -
.000
0.00
0.00
0.00
Line A
A-1,1 W->E
HDQ8 6X6
3336
.033 .000 0.033
- -
.076
0.04
0.15
0.50
E->W
HDQ8 6X6
3211
.032 .000 0.032
- -
.076
0.04
0.15
0.50
A-1,2 W->E
HDQ8 6X6
3336
.033 .000 0.033
- -
.076
0.04
0.15
0.50
E->W
HDQ8 6X6
3462
.034 .000 0.034
- -
.076
0.04
0.15
0.51
Line B
B-1 Both
HDU5-SDS
1267
.025 .000 0.025
- -
.076
0.04
1. 0.14
0.08
Legend:
Wall, segment- Wall and segment between openings, e.g. B-3, 2 = second segment on Wall 3 on Shearline B
Dir- Force direction
Uplift force (P) -Strength-level accumulated hold-down tension force from overturning, dead and wind uplift. For perforated walls, T from SDPWS 4.M is
used for overturning
da - Vertical displacements due to the following components:
Elong/Disp - Elongation when slippage calculated separately; displacement when combined elongation/slippage used
Manuf - Using manufacturer's value for anchor bolt length, or no bolt contribution for connector -only elongation.
Unless marked with * = (ASD uplift force / ASD hold-down capacity) x max strength -level elongation or displacement
" - Maximum strength -level elongation or displacement is used. May result in higher than actual displacements for lightly loaded hold-downs, causing
the segment to draw less force due to lower than actual stiffness.
Add - Due to longer anchor bolt length than manufacturer's value, or entire bolt length for connector -only elongation = PL / ( Ab x Es );
Ab - bolt cross -sectional area;
Es = steel modulus = 29000000 psi;
L = Lb - Lh;
Lb = Total bolt length shown in Stoney information table;
Lh = Manufacturer's anchor bolt length forgiven displacement/elongation from hold-down database.
Slippage - Due to vertical slippage of hold-down fasteners attached to stud(s) when not combined with elongation
Pf = ASD uplift force P / number of fasteners
Bolts: = Pf/ (270,000 D"1.5) (NDS 11.3.6) ; D = bolt diameter
Nails: = an, from SDPWS Table C4.2.2D using Pf for Vn and values for Wood Structural Panel
Shrink- Wood shrinkage = 0.002 x (19% fabrication - 10% in-service moisture contents) x Ls
Ls = Parp.-to-grain length between fasteners subject to shrinkage, shown in Storey Information table
Crush + Extra - 0.04" wood crushing at compression end of wall segment plus extra displacement due to miscuts, gaps, etc.
Total da = Elong/Disp + Slippage + Shrink + Crush + Extra
Hold Deft - Horizontal deflection = h/b x da (4th term in the deflection equation SDPWS C4.3.2-1)
h = wall height, b = segment length between openings; h,b values in Deflection table
WARNING - At least some hold-downs do not have displacement values for the thickness of end studs selected, so additional jack studs or blocking
required.
21
Woodworks® Shearwalls Farmington garage.wsw Sep. 20, 201711:49:24
STORY DRIFT iffexihle seismic desinnl
j
wall
Actual Story Drift (in)
I Allowable Story Drift
Level Dir
height
Max Line
Max Center
C of M
C of M
hsx Delta a Ratio
It
dxe
dx of Mass
dxe
dx
ft in Max C of M
1
13.50
13.SU 4.05
N<->S
0.14 1
0.56 11.50
0.14
0.56
0.14 0.14
E<->➢7
0.62 A
2.49 16.00
0.38
1.51
0.61 0.37
ASCE 7 Eqn. 12.8-15::dx = dxe x [;d I le
Deflection amplification factor Cd from Table 12.2-1 = (E-W), 4.0 (N-S)
Importance factor le = 1.00
Legend:
Max dxe - Largest deflection for any shearfine on level in this direction; refer to Deflections table
Line - Sheadine with largest deflection on level in this direction
hsx - Story height in ASCE Table 12.12-1 = Height of walls plus joist depth between this Level and the one above.
Max dx - Largest ampiffitied deflection on level in this direction using ASCE 7 Eq'n 12.8-15
C of M dxe - Deflection at the center of mass of this level; from interpolating deflections at adjacent sheadines.
C of M dx - Amplified deflection at center of mass using Eq'n 12.8-15. Does not include differences between top and bottom diaphragm deflection.
Delta a = Allowable story drift on this level from ASCE 7 Table 12.12-1
Ratio - Proportion of allowable story drift experienced, on this level in this direction.
`V,
WoodWorks® Shearwalls
Farmington garage.wsw
Sep. 20, 2017 11:49:24
23
Project: I. ,
Location: RFB1 Farmington Aof , Aevx `
goof Beam
[2016 Califomia Building Code(2012 NDS)]
5.5 IN x 12.0 IN x 16.0 FT
24F-V4 - Visually Graded Western Species - Dry Use
Section Adequate By: 51.3%
Controlling Factor: Moment
❑EFLECTIO Center
Live Load 0.34 IN U565
Dead Load 0.31 in
Total Load 0.65 IN U296
Live Load Deflection Criteria: U240 Total Load Deflection Criteria: U180
REACTIONS A B
Live Load 2627 lb 2627 lb
Dead Load 2391 lb 2391 lb
Total Load 5018 lb 5018 lb
Bearing Length 1.40 in 1.40 in
BEAM DATA
Span Length 16 ft
Unbraced Length -Top 0 ft
Unbraced Length -Bottom 0 ft
Roof Pitch 4 12
Roof Duration Factor 1.15
MATERIAL PROPERTIES
24F-V4 - Visually Graded Western Species
Base Values
Adiusted
Bending Stress:
Fb =
2400 psi
Controlled by_
Fb_cmpr =
1850 psi
Fb' = 2760 psi
Cd=1.15
Shear Stress:
Fv =
265 psi
Fv' = 305 psi
Cd=1.15
Modulus of Elasticity:
E =
1800 ksi
E' = 1800 ksi
Comp. -I- to Grain:
Fc -1=
650 psi
Fc - -L = 650 psi
Controlling Moment: 20071 ft-lb
8.0 ft from left support
Created by combining all dead and live loads.
Controlling Shear: 5018 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections:
Read
Provided
Section Modulus:
87.27 in3
132 in3
Area (Shear):
24.7 in2
66 in2
Moment of Inertia (deflection):
481.64 in4
792 in4
Moment:
20071 ft-lb
30360 ft-lb
Shear.
5018 lb
13409lb
NOTES
John Acosta ARA, Architect
Mountain Architecture Inc.
PO Box 6167
Big Bear Lake CA 92315
StruCalc Version 10.0.1.4 9/20/2017 11:53:43 AM
LOADING DIAGRAM
AL
A
ROOF LOADING
Side One:
Roof Live Load:
LL =
18.2
psf
Roof Dead Load:
DL =
15
psf
Tributary Width:
TW =
16
ft
Side Two:
Roof Live Load:
LL =
18.2
psf
Roof Dead Load:
DL =
15
psf
Tributary Width:
TW =
2
ft
Wall Load:
WALL =
0
plf
Non -Snow Roof Loaded Area:
RLA =
288
plf
ft
Adjusted Beam Length:
Ladj =
16
Beam Self Weight:
BSW =
14
plf
Beam Uniform Live Load:
wL =
328
plf
Beam Uniform Dead Load:
wD_adj =
299
plf
Total Uniform Load:
4T =
627
PH
/orris
Sa1C. %G VAL.,
(/ zJ
j,o (1,11)' ZZ- J
Project:
Location: COL2 Farmington
Column
[2016 California Building Code(2012 NDS)]
1.5 IN x 5.5 IN x 13.5 FT @ 16 O.C.
#2 - Douglas -Fir -Larch - Dry Use
Section Adequate By: 30.7%
DEFLECTIONS
Deflection due to lateral loads only: Deft = 0.69 IN = U235
Live Load Deflection Criteria: U180
VERTICAL
Live Load: Vert-LL-Rxn = 907 lb
Dead Load: Vert-DL-Rxn = 704 lb
Total Load: Vert-TL-Rxn = 1611 lb
HORIZONTAL REACTIONS
Total Reaction at Top of Column: TL-Rxn-Top = 207 lb
Total Reaction at Bottom of Column: TL-Rxn-Bottom = 207 Ib
COLUMN DATA
Total Column Length:
13.5 ft
Unbraced Length (X-Axis) Lx:
13.5 ft
Unbraced Length (Y-Axis) Ly:
0 ft
Column End Condition-K (e):
1
Axial Load Duration Factor
1.00
Lateral Load Duration Factor (Wind/Seismic)
1.60
92 - Douglas -Fir -Larch
Compressive Stress:
Bending Stress (X-X Axis):
Bending Stress (Y-Y Axis):
Modulus of Elasticity:
Stud Section (X-X Axis):
Stud Section (Y-Y Axis):
Area:
Section Modulus (X-X Axis):
Section Modulus (Y-Y Axis):
Slenderness Ratio:
Base Values Adiusted
Fc = 1350 psi Fe = 520 psi
Cd=1.60 Cf=1.10 Cp=0.22
Fbx = 900 psi Fbx' = 2153 psi
Cd=1.60 CF=1.30 Cr=1.15 C1=1.00
Fby = 900 psi Fby' = 2153 psi
Cd=1.60 CF=1.30 Cr--1.15
E = 1600 ksi E' = 1600 ksi
dx =
5.5
in
dy=
1.5
in
A =
8.25
in2
Sx =
7.56
in3
Sy =
2.06
in3
Lex/dx =
29.45
Ley/dy =
0
Stud Calculations (Controlling Case Only):
Controlling Load Case: Axial total Load and Lateral loads (D + 0.75[L + W]
Actual Compressive Stress:
Fc =
168
psi
Allowable Compressive Stress:
Fc' =
520
psi
Eccentricity Moment (X-X Axis):
Mx -ex =
0
ft-lb
Eccentricity Moment (Y-Y Axis):
My-ey =
0
ft-lb
Moment Due to Lateral Loads (X-X Axis):
Mx =
524
ft-lb
Moment Due to Lateral Loads (Y-Y Axis):
My =
0
ft-lb
Bending Stress Lateral Loads Only (X-X Axis): Fbx =
831
psi
Allowable Bending Stress (X-X Axis):
Fbx' =
2153
psi
Bending Stress Lateral Loads Only (Y-Y Axis): Fby =
0
psi
Allowable Bending Stress (Y-Y Axis):
Fby' =
2153
psi
Combined Stress Factor:
CSF =
0.66
John Acosta ARA, Architect
Mountain Architecture Inc.
PO Box 6167
Big Bear Lake CA 92315
StruCalc Version 10.0.1.4 9120/2017 1:24:28 PM
LOADING DIAGRAM
B
1a.s
A
AXIAL L ADIN
Live Load:
PL =
680 plf
Dead Load:
PD =
510 plf
Column Self Weight:
CSW =
24 plf
Total Axial Load:
PT=
1214plf
LLATERAL,LOADING
(DyFace)
Uniform Lateral Load:
wL-Lat =
23 psf