Loading...
BSOL2017-0018Applicant: /Q\ Contractor: PETERSEN-DEAN INC DBA PETERSENDEAN D /All a PETERSEN-DEAN INC DBA PETERSENDEAN 39300 CIVIC CENTER DRIVE 39300 CIVIC CENTER DRIVE FREMONT, CA 94538 AUG 2 9 ZO,? FREMONT, CA94538- CITYQFLA QUINTA (510)371-6500 COMMUNITYDEVELOPMENTDEPARTMEN7. Llc. No.: 468117 LICENSED CONTRACTOR'S DECLARATIONWORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am lic sed under provisions of Chapter 9' 1 hereby affirm under penalty of perjury one of the following declarations: {commencing with Section 7000) of -Division 3 of e B siness and Professions Code, and _ I have and will maintain a certificate of consent to self -insure for workers' my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: C39 C36 C20 C10 C43 ices o.: 468117 of the work for which this permit is issued. • 00— 1 have and will maintain workers' compensation insurance, as required by TAty, 4 0"Aro VOICE (760) 777,-7125 78-495 CALLS TAMPICO issued. My workers' compensation,insurance carrier and policy number are: D I hereby affirm under penalty of perjury that I am exempt from the Contractor's State _ License Law for the following reason (Sec. 7031.5, Business and Professions Code:.Any FAX (760) 777-7011DESIGN LA QUINTA, CALIFORNIA 92253 & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 compensation laws of California, and agree that, i shou d become subject to the statement that he or she is licensed pursuant to the provisions of the Contractor's State BUILDING PERMIT License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business comply with those provisions. and Professions Code) or that he or she is exempt therefrom and the basis for the L f Date: 8/29/2017- /29/2017Application ApplicationNumber: BSOL2017-0018 Owner: Property Address: 77877 CALLE ARROBA AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO REBECCA MARTINEZ APN: 774172001 COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF.THE LABOR CODE, 77877 CALLS ARROBA Application Description: MARTINEZ / 3.5kW PV SYSTEM - (12) 295W PANELS+MICROINVERTERS LA QUINTA, CA 92253 Property Zoning: APPLICANT ACKNOWLEDGEMENT or she did not build or improve for the purpose of sale.). IMPORTANT: Application is hereby made to the Building Official for a permit subject to Application Valuation: $13,000.00 construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State 1. Each person upon whose behalf this application is made, each person at whose Applicant: /Q\ Contractor: PETERSEN-DEAN INC DBA PETERSENDEAN D /All a PETERSEN-DEAN INC DBA PETERSENDEAN 39300 CIVIC CENTER DRIVE 39300 CIVIC CENTER DRIVE FREMONT, CA 94538 AUG 2 9 ZO,? FREMONT, CA94538- CITYQFLA QUINTA (510)371-6500 COMMUNITYDEVELOPMENTDEPARTMEN7. Llc. No.: 468117 LICENSED CONTRACTOR'S DECLARATIONWORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am lic sed under provisions of Chapter 9' 1 hereby affirm under penalty of perjury one of the following declarations: {commencing with Section 7000) of -Division 3 of e B siness and Professions Code, and _ I have and will maintain a certificate of consent to self -insure for workers' my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: C39 C36 C20 C10 C43 ices o.: 468117 of the work for which this permit is issued. • 00— 1 have and will maintain workers' compensation insurance, as required by Date: Contra tor: XJ� Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation,insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: DEPARTMENT OF INDUSTRIAL RELATIONS Policy Number: SP4056778 I hereby affirm under penalty of perjury that I am exempt from the Contractor's State _ License Law for the following reason (Sec. 7031.5, Business and Professions Code:.Any _ I certify that in the performance of the work for which this permit is issued, I city or county that requires a permit to construct, alter, improve, demolish, or repair any shall not employ any person in any manner so as to b e subject to the workers' structure, prior to its issuance, also requires the applicant for the permit to file a signed compensation laws of California, and agree that, i shou d become subject to the statement that he or she is licensed pursuant to the provisions of the Contractor's State workers' compensation provisions of Sectio 7 0 of th Labor Code, I shall forthwith License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business comply with those provisions. and Professions Code) or that he or she is exempt therefrom and the basis for the L f alleged exemption. Any violation of Section 7031.5 by any applicant for a permit Dater App cant: subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, compensation, will do the work, and the structure is not intended or offered for sale. AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF apply io an owner of property who builds or improves thereon, and who does the work COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF.THE LABOR CODE, himself or herself through his or her own employees, provided that the: improvements INTEREST, AND ATTORNEY'S FEES. are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he APPLICANT ACKNOWLEDGEMENT or she did not build or improve for the purpose of sale.). IMPORTANT: Application is hereby made to the Building Official for a permit subject to (� I, as owner of the property, am exclusively contracting with licensed contractors to the conditions and restrictions set forth on this application. construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State 1. Each person upon whose behalf this application is made, each person at whose License Law does not apply to an owner of property who builds or improves thereon, . request and for whose benefit work is performed under or pursuant to any permit issued and who contracts for the projects with a contractor(s) licensed pursuant to the as a result of this application , the owner, and the applicant, each agrees to, and shall Contractors' State License Law.). defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and (� I am exempt under Sec. B.&P.C. for this reason employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not Date: Owner: commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). .Lender's Na Lender's Address: I certify that I have read this application and state that the above infor 'on is correct. I agree to comply with all city and county ordinances and state la relati7 to building construction, and hereby authorize representatives of this enter upon the above- mentioned property for inspection purposes. Date: 40 ��� Signature (Applicant or Ag t): / Date: 8/29/2017 Application Number: BSOL2017-0018 Owner: Property Address: ,"•77877 CALLE ARROBA REBECCA MARTINEZ APN: 774172001 77877 CALLE ARROBA Application Description: MARTINEZ / 3.5kW PV SYSTEM - (12) 295W PANELS+MICROINVERTERS LA QUINTA, CA 92253 Property Zoning: Application Valuation: $13,000.00 Applicant: Contractor: PETERSEN-DEAN INC DBA PETERSENDEAN PETERSEWDEAN INC DBA PETERSENDEAN. 39300 CIVIC CENTER DRIVE 39300 CIVIC CENTER DRIVE FREMONT, CA 94538 FREMONT, CA 94538 (510)371-6500 Llc. No.: 468117 ------------------------------------------------------------------------------------------- Detail: 3.5kW SOLAR ARRAY - (12) 295W MISSION SOLAR PANELS + ENPHASE M250-60 MICROINVERTERS W/(1) 60 AMP SUBPANEL [216SF] 2016 CALIFORNIA ELECTRICAL CODE. 1 FINANCIAL INFORMATION :. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid -for BUILDING STANDARDS ADMINISTRATION BSA: • $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 1OKW 101-0000-42403 0 .$25.33 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 1OKW PC 101-0000-42600 0 $25.33 Total Paid for ELECTRICAL: $50.66 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 10170000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 F $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin# City o'La Quinta n(-) ?/ Building &Safety Division ' 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Shi et Permit# O� Project Address: -7-7007-7 0(4tt �A izIrU 6 Owner's Name: Re, CCC 4 r%a E2- A.P. Number Address: % i8 7j 0Y_ILL G 4q_�# Legal Description: City, ST, Zip: kr GA 7 Z 2 3 Contractor: T C(eRSen Telephone: e f g_ _ . Address: I'D20 !iceI1L}IIV�Pi2 /R— Project Description: n ��i +' WIG�►w�' C City, ST, Zip: I��d6Qs •De C IZsO S 5-feo1L— -3-S-1 k to - 12- 2Telephone: Telephone: %&0- g68'2,_I - ---- - ------ - State Lic. #: tf G bCity Lic #: Arch, Engr., Designer: Address: City, ST, Zip: Telephone: Construction Type: Proj. Type=)Add'n Occupancy: Alter Repair Demo State Lia #: Name of Contact: tJb Y L S q e �, / SgFt: #Stories #Units: Telephone of Contact: D ®� I .O � i� Estimated Value of Project: 1 tib APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Ree'd TRACKING PERMh FEES Plan Sets Plan Check Submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan Check Balance: Title 24 Calcs Plans Picked Up Construction: Flood Plain Plan Plans Resubmitted Mechan_cal: Grading Plan 2nd Rev, Ready for corrections / ElectricEl: Subcontractor List Called Contact Person Plumbing: Grant Deed .. Plans Picked Up S.M.I. HOA Approval Plans Resubmitted Grading 1N-HOUSE 3rd Rev, Ready for corrections / Develop-tr Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Apps Date of permit issue School Fees Total Permit Fees 00 .. SHEET INDEX PV -I ' SOLAR LAYOUT PV -2 ATTACHMENT DETAILS PV -5 ELECTRICAL LINE DIAGRAM PV -4 PLOT PLAN NOTES: - Solar Photovoltaic System to be installed on residential structure. -Design complying with the latest edition of California Electrical Code, NEC and all local ordinances and policies. -The project has been designed in compliance with the CBC section 1609 to withstand a minimum 110 MPH wind load. - Per sections R314 & R315 within the 2016' California Residential Code (CRC), it's required that smoke alarm and carbon monoxide detectors are retrofitted into the existing dwelling for permits with repairs or additions exceeding $1,000. Working distances around the existing electrical equipment as well as the new electrical equipment will be maintained in accordance with CEC 110.26 - This system will not be interconnected until approval from the local jurisdiction and the utility is obtained. -This system is a utility interactive system with no storage batteries. -The Solar Photovoltaic installation shall not obstruct any plumbing, mechanical or building roof vents. - When a backfed breaker is the method of utility interconnection, breaker shall not read Line and Load. - All PV equipment shall be listed by a recognized testing lab. - Notify serving utility before PV system activation. CODE COMPLIANCE PROJECT DE5I6NED BASED ON 2016 CEO - ALL SUPPLIED -EQUIPMENT 15•UL—LISTED - 2016 CALIFORNIA BUILDING, CODE 2016 CALIFORNIA ELECTRIC CODE 2016 CALIFORNIA FIRE DEPARTMENT CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 ENERGY COMPLIANCE T-24 2014 NATIONAL ELECTRIC CODE LU LU SWIMMING POOL CALLE ARROBA n SOLAR LX%rOUT SCALE: 3/32"=1'-0" (12) QTY 2gsW SOLAR MODULES 5.54 kH DG BUILDING & SAFETY DEPG APPROVED FOR CONSTRUCTION �I PROPERTY -- . F b AZIMUTH 180° FROM NORTH Y ° 'ia El PETERSENDEAN SmarferRoofs ' - Solar Energy - Services 40 1820 GONTA IRGLE O RIVER5ID GA 9 509 P: 216-48 0 N e rsen ean.com r ,46 G LIG NS o. 468117 `� 10 G PROJECT NAME: MARTIN EZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CI (12) MISSION SOLAR ENERGY MSE295S (12) ENPHASE M250-72-2LL-S22 DRAHIN6 NOTES: MODULE RATED AT- 295W MULTIPLY BY QTY. OF MODULES: 12 ARRAY SYSTEM 517E. 3.54pkW SYSTEM AZIMUTH. 1000 ROOF PITCH. 16°= 4/12 MOUNTING HEIGHT: 1 -STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OMER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING WH 0 8/1 112 01 7 PV - 1 © 2011 PETERSENDEAN SOLAR 8 ROOFING INC., ALL RIGHT5 RESERVED i k i f� �F c SYMBOL LEGENDi" MECHANICAL B p PLUMBING VENTS , CHIMNEY I SOLAR MODULES — _ E E GSFM 5' SETBACKS t • s CONDUIT , MAIN SERVICE PANEL AI AND UTILITY METER AC COMBINER BOX AG DISCONNECT > a JUNCTION BOX GAS METER 5 OG s PROPERTY -- . F b AZIMUTH 180° FROM NORTH Y ° 'ia El PETERSENDEAN SmarferRoofs ' - Solar Energy - Services 40 1820 GONTA IRGLE O RIVER5ID GA 9 509 P: 216-48 0 N e rsen ean.com r ,46 G LIG NS o. 468117 `� 10 G PROJECT NAME: MARTIN EZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CI (12) MISSION SOLAR ENERGY MSE295S (12) ENPHASE M250-72-2LL-S22 DRAHIN6 NOTES: MODULE RATED AT- 295W MULTIPLY BY QTY. OF MODULES: 12 ARRAY SYSTEM 517E. 3.54pkW SYSTEM AZIMUTH. 1000 ROOF PITCH. 16°= 4/12 MOUNTING HEIGHT: 1 -STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OMER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING WH 0 8/1 112 01 7 PV - 1 © 2011 PETERSENDEAN SOLAR 8 ROOFING INC., ALL RIGHT5 RESERVED 50LAR PANEL CONCRETE LOW PROFILE TILE 55 TILE HOOK UNIRAG MID CLIP W/T-BOLT 4 FLANGE NUT UNIRAG ALUM. SUPPORT RAIL 3/8"-I6 X 5/4 HEX HEAD BOLT 5/8-16 FLANGE NUT QUICK50REH q0° 55 TILE HOOK N -FLA5HING 16° 14 12 2x4 TRU55E5 24" OG TYP (2) 5/16" x 4" 55 LAG BOLT INTO TRU55(ES) 2 1/2" MIN. :055 SHEATHING PENETRATION hl/ ROOF 5EALANT, TYP. SCALE I " = I' CITY OF LA QUINTA BUILDING &® T. SAFETY DEP APPROVED FOR CONSTRUCTION DATE BY PARTIAL ROOF FRA INS FLA SCALE: 5/52"=1'-0" Maxirnum, fb6f load: 2.63 lhs/ft2` Maximum point load: 25.69.41bIs%attachment Model; Mission Solar Energy -'1 SE295SQ5T Weight: 40.1, Lbs Width: 39.:33 Inches Length: °65:57 'lnches -- - - E AZIMUTH Ib0" B FROM NORTH F. c b 5 P 0 PETERSENDEAN Smarferitoofs ' • Solar Energy Services ID20 CONTAINER CIRCLE RIVERSIDE, GA q P: (q51 2"16— q0 w pe ende .com A LIG E No 468118 G-10 -46 JEGT NAME: MARTINEZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CITY OF (12) MISSION SOLAR ENERGY MSE:29SS05T (12) ENPHASE M250-72-2LL-S22 (240V) DRAWING NOTES: MODULE RATED AT, 295W MULTIPLY BY QTY. OF MODS 54 12 ARRAY SYSTEM 517E• SYSTEM AZIMUTH. 1800 ROOF PITCH. 16*= 4//112/ MOUNTING HEIGHT: 1—STORY 1 ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND P0551BLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING WH 08/11/2017 PV -2 © 2017 PETERSENDEAN SOLAR 8 ROOFING INC., ALL RIGHTS RESERVED i E t 1/5*L MAX. L = 48" O.G. MAX /5*L MAX. TYP. CONT. ALUM. TYR (V i € RAIL m +1 m € H LuLu i Q < J (22) QTY ATTACHMENT c POINTS AT 48" OC MAX b. �E 93 II I m, t Iltltltltl Itl Itltl tllll•I� _� ' Ildldlbldl Ibldlbl�l dlllll'^ L, END MOUNTING MID. MOUNTING CLIP, TYP. CLIP, TYP. I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IIIIIIII•PARTIALLY VAULTED CIEILIING IIIIIIIIIIII RACX MOUNT LA�ONT III°II 2x4 WT�yT"rFIC,AL I k m i AT 24"YP SCALE: 1/2"=I' -O" 111111111111111111.1111111111111111 111111111111111111,1111111111.111111`1 50LAR PANEL CONCRETE LOW PROFILE TILE 55 TILE HOOK UNIRAG MID CLIP W/T-BOLT 4 FLANGE NUT UNIRAG ALUM. SUPPORT RAIL 3/8"-I6 X 5/4 HEX HEAD BOLT 5/8-16 FLANGE NUT QUICK50REH q0° 55 TILE HOOK N -FLA5HING 16° 14 12 2x4 TRU55E5 24" OG TYP (2) 5/16" x 4" 55 LAG BOLT INTO TRU55(ES) 2 1/2" MIN. :055 SHEATHING PENETRATION hl/ ROOF 5EALANT, TYP. SCALE I " = I' CITY OF LA QUINTA BUILDING &® T. SAFETY DEP APPROVED FOR CONSTRUCTION DATE BY PARTIAL ROOF FRA INS FLA SCALE: 5/52"=1'-0" Maxirnum, fb6f load: 2.63 lhs/ft2` Maximum point load: 25.69.41bIs%attachment Model; Mission Solar Energy -'1 SE295SQ5T Weight: 40.1, Lbs Width: 39.:33 Inches Length: °65:57 'lnches -- - - E AZIMUTH Ib0" B FROM NORTH F. c b 5 P 0 PETERSENDEAN Smarferitoofs ' • Solar Energy Services ID20 CONTAINER CIRCLE RIVERSIDE, GA q P: (q51 2"16— q0 w pe ende .com A LIG E No 468118 G-10 -46 JEGT NAME: MARTINEZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CITY OF (12) MISSION SOLAR ENERGY MSE:29SS05T (12) ENPHASE M250-72-2LL-S22 (240V) DRAWING NOTES: MODULE RATED AT, 295W MULTIPLY BY QTY. OF MODS 54 12 ARRAY SYSTEM 517E• SYSTEM AZIMUTH. 1800 ROOF PITCH. 16*= 4//112/ MOUNTING HEIGHT: 1—STORY 1 ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND P0551BLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING WH 08/11/2017 PV -2 © 2017 PETERSENDEAN SOLAR 8 ROOFING INC., ALL RIGHTS RESERVED LABELS NEC,640.5(C) - AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION (AND ALL' BATTERY LOCATIONS IF, APPLICABLE): WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 640.13 (B), 690.15(A)(4) -;ON AG DISCONNECT: AC PHOTOVOLTAIC DISCONNECT' NEC, 640.19 - AT JUNCTION BOX,' COMBINER BOXES'AND.AC DISCONNECTSF WARNING ' ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION- ' NEC 640.55(F) - UNGROUNDED PV SYSTEMS ONLY AT EACH .JUNCTION BOX,,COMBINER BOX; DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY EXP05ED DURING SERVICE: WARNING • ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED i NEC 640.5b(C) -:AT PV SYSTEM DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 640.52 - ON AG DISCONNECT POINT OF INTERCONNECTION: PHOTOVOLTAIC SYSTEM 'AC SYSTEM SPECIFICATIONS ` MAX. AC ouTPLrr CURRENT: � 12 A OPERATING AC VOLTAGE: 240 V ' .OPERATING AC POWER: _ - 2880 W OPERATING AC FREQUENCY: 60 H. MAXIMUM OCPDRATING: 15 A NEC,905,12(D)(2) - BY BREAKER AT DISTRIBUTION EQUIPMENT: WARNING INVERTER OUTPUT CONNECTION 00 NOT _RELOCATE' THIS OVERCURRENT DEVICE. NEG -905.10 - "AT SERVICE EQUIPMENT LOCATION? CAUTION THE ELECTRICAL SYSTEM IS ALSO SERVICED BY A PHOTOVOLTAIC SYSTEM GSFM- AG CONDUIT EVERY 10,' INTERIOR/EXTERIOR -WARNING: PHOTOVOLTAIC POWER SOl1RCE - PLAGVE5 SHALL BE;PLA5TIC- ENGRAVED IN A CONTRASTING COLOR TO.THE PLAQUE'PLAQUE �5HALL BE: ATTACHED M THE GE EQUIPMENT. WI AD pulp NOTE5 1. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF:CALIFORNIA ELECTRICAL CODE WILL BE INSTALLED AS REQUIRED. 2. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING -COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED BY POP RIVER RES WOR OTHER APPROVED' METHOD. IF EXPOSED TO SUNLIGHT.i, IT SHALL BE UV RESISTANT. _ TS OSC- - - 3.. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE._ 4. EACH MODULE SHALLBE GROUNDED USING THE SUPPLIED CONNEDECTION POINT IDENTIFION THE MODULE AND THE MANUFACTURERS INSTRUCTIONS. _ - _. -. 5. 'IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METAWC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE 6.. PHOTOVOLTAIC EQUIPMENT SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. 7.' ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE USTED AS SUNLIGHT RESISTANT 8. EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A RACEWAY. - ~ 7 PROVIDE SMOKE ALARMS AT THE FOLLOWING LOCATIONS AND NOTE ON THE PLANS; (R314.3 CRC) • A. O.UTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITYOF BEDROOMS.. B. IN EACH ROOM USED FOR SLEEPING PURPOSES. C. IN EACH STORY, INCLUDING BASEMENTS. IN SPLIT LEVEL UNITS WITHOUT AN INTERVENING DOOR BETWEEN ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELORE THE UPPER LEVEL.. - D. ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTUATION OF ONE ALARM SHALL ACTIVATE ALL ALARMS. E. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACKUP. ' F. APPROVED COMBINED SMOKE ALARMS AND CARBON DIOXIDE ALARMS SHALL BE ACCEPTABLE., A CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN THE SPECIFIC EXISTING DWELLING UNIT THAT HAVE ATTACHED GARAGES OR FUEL -BURNING APPLIANCES FOR WHICH A PERMIT IS ISSUED FOR ALTERATIONS. REPAIRS, OR ADDTIONS EXCEEDING $1,000.00. LISTED SINGLE - OR MULTI -STATION CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. COMBINED SMOKEICARBON MONOXIDE ALARMS MAY BE USED. THE ALARM SMALL RECEIVE ITS PRIMARY POWER FROM THE BUILDING WIRING EXPECT IT IS PERMITTED TO BE SOLEY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED OR THERE IS NO ACCESS BY MEANS OFF AN ATTIC. SHOW ON THE PLANS (R315 CRC) - COMPLY WITH CEC SEC. 690.15 (A).4 AND INSTALL A PLAQUE IN ACCORDANCE WITH SEC.705.10 AS FOLLOWS: 705.10 DIRECTORY: A PERMANENT PLAQUE OR DIRECTORY, DENOTING AN ELECTRIC POWER SOURCES ON OR IN THE PREMISES,. SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT LOCATIONS OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OR BEING INTERCONNECTED. PHOTO -VOLTAIC PANEL THERE ARE NOT INTEGRAL PART OF THE ROOF COVERING SYSTEM SHALL BE INSTALLED WITH A MINIMUM THREE (3) INCH'CLEARANCE FROM THE SURFACE TO THE PANEL COMPLY WITH CEC ARTICLE 250.56 FOR EXISTING RESISTANCE OF ROD, PIPE; AND PLATE ELECTRODES. A SINGLE ELECTRODE CONSISTING OF A ROD, PIPE. OR PLATE THAT DOES NOT HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS SHALL BE AUGMENTED BY ONE ADDITIONAL ELECTRODE OF ANY OF THE TYPES SPECIFIED BY 250.52(Ax4) THROUGH (A)(8). WHERE MULTIPLE ROD, PIPE, OR PLATE ELECTRODES ARE • INSTALLED TO MEET THE REQUIREMENTS OF THIS SECTION, THEY SHALL NOT BE LESS THAN 1.8 M (6 Fr) APART. SHALL. PROVIDE AN AUXIUARY GROUNDROF IT IT CANNOT BE PROVEN THAT THE EXISTING GROUNDING HAS HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS. •,(I) 5A SPB ENVOY=5 METERED o e (U 20A' DPD .PHOTOVOLTAIC ARRAY ,BRANCH CIRCUIT I =d.2 MODULE51 EGG � Mail Brandi AC required conductor ampacity (1)(12)(L25)oSA _. _. Awls kl • derated ampacity:' (40)(0.58)(1) "23.2A 23.2A > 15A ; thereforeACwlre size Is valid Combined System AC required conductor ampadty (1)(12)(1.25) m 15A AWGt)10 deratedampacity:. I (40) (0.82) (1) = 32.8 h2.87;_fSr._th_miWreACwire 9ze Fs vollck Notm Cnndu 4 iN It be Installed Min l/2'a bow roe suM cr. J (E)2OO A z PV BREAKER' 15A DPB G .. .. - G A I G CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY ENPHA5E AC' EIS16ASE GABLE IN FREE AIR LI = BLACK; L2,- RED, N - WHITE 6 =GREEN - - E60'= AW6 #6 BARE GU BRANCH CIRCUIT #I, IsC.= 12A G G (E)2OO A z PV BREAKER' 15A DPB G .. .. - G THWN-2 IN I G CHALLENGER, 0215 3/4" EMT MAIN SERVICE '" _ 'LOCATED FARTHEST PANEL THWN=2�IN LI = BLACK. FROM M5D 5/4" EMT JUNCTION� INSTALL NEW AW_ 6, #10 'BOX 60 A RATED LI = BLACK. 50,A RATED -AC, COMBINER L2 = RED , 6 =:GREEN BOX, METERED I ENPHASE RAMI=120 . 015CONNECT ENPHA5E AC' EIS16ASE GABLE IN FREE AIR LI = BLACK; L2,- RED, N - WHITE 6 =GREEN - - E60'= AW6 #6 BARE GU BRANCH CIRCUIT #I, IsC.= 12A G G (E)2OO A z MAIN DISCONNECT 6 G .. .. - G THWN-2 IN I G 3/4" EMT MAIN SERVICE AWG #10 PANEL THWN=2�IN LI = BLACK. 5/4" EMT L2 = RED INSTALL NEW AW_ 6, #10 N;= WHITE 60 A RATED LI = BLACK. AW6. #8 -AC, COMBINER L2 = RED , 6 =:GREEN BOX, METERED N'. P4HITE ENPHASE RAMI=120 AWG #8 .240 V 6 = GREEN ,*SOLAR PV USE ONLY, NOT DISTRIBUTION EQUIPMENT* BI-DIRECTIONAL 1 UTILITY PHAS METER I I PHASE, 3 WIRE 120/240 V NEW; IF NO EXISTING GROUNDING'; ELECTRODE i M PETPRSENDEAN 5l110r�OfROOf/°Y ..sp�p/(Tpr�r SpfVICED I I '1520 CONTAINER CIRCLE RIVERSIDE,C '43509 P: PC rse cin.com A L NSE 46BI19 G*I - G- 1 PROJECT NAME: I MARTINEZ RESIDENCE, i i ,77877 CALLE ARROBA LA'QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA,.,CITY OF - (12) MISSION SOLAR ENERGY MSE295S05T (12) ENPHASE M250.722LLS22 (240V) DRAWING NOTES,. MODULE RATED AT- 295 V V MULTIPLY BY QTY: OF MODULES: 12 ARRAY SY57*EM SIZE. 3.54 kw' SYSTEM AZIMUTH: c 1800 ROF OPITCH 1 6'- 4/12 MOLNTIN6 HEIGHT: 1 -'STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY, LOCATIONS ARE TO BE REVIEWED AND'APPROVED BY OWNER AND/OR "ARCHITECT OF RECORD TO, VERIFY SYSTEM LOCATION, FOR, VENTILATION OBSTRUCTION'AND' POSSIBLE RELOCATION OF VENT AND/OR PIPE-JAGKS. - .FIELDVERIFICATION -OF ROOF STRUCTURE, 'AND,SOLAR ARRAY VOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR "ALL'EXISTIN6' STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. - ARCHITECT/FIELD DRAWING INFORMATION PERMITTING MIH oam Iik17 APV -3. © 201-1 PETERSENDEAN SOLAR 4 ROOFING INC:, ALL RI6HT5 RESERVED, (E)2OO A z MAIN DISCONNECT 6 EXISTING; ° 4 ' � _ _ 200'A: RATED E CHALLENGER MAIN SERVICE • •'- PANEL y H � NEW; IF NO EXISTING GROUNDING'; ELECTRODE i M PETPRSENDEAN 5l110r�OfROOf/°Y ..sp�p/(Tpr�r SpfVICED I I '1520 CONTAINER CIRCLE RIVERSIDE,C '43509 P: PC rse cin.com A L NSE 46BI19 G*I - G- 1 PROJECT NAME: I MARTINEZ RESIDENCE, i i ,77877 CALLE ARROBA LA'QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA,.,CITY OF - (12) MISSION SOLAR ENERGY MSE295S05T (12) ENPHASE M250.722LLS22 (240V) DRAWING NOTES,. MODULE RATED AT- 295 V V MULTIPLY BY QTY: OF MODULES: 12 ARRAY SY57*EM SIZE. 3.54 kw' SYSTEM AZIMUTH: c 1800 ROF OPITCH 1 6'- 4/12 MOLNTIN6 HEIGHT: 1 -'STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY, LOCATIONS ARE TO BE REVIEWED AND'APPROVED BY OWNER AND/OR "ARCHITECT OF RECORD TO, VERIFY SYSTEM LOCATION, FOR, VENTILATION OBSTRUCTION'AND' POSSIBLE RELOCATION OF VENT AND/OR PIPE-JAGKS. - .FIELDVERIFICATION -OF ROOF STRUCTURE, 'AND,SOLAR ARRAY VOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR "ALL'EXISTIN6' STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. - ARCHITECT/FIELD DRAWING INFORMATION PERMITTING MIH oam Iik17 APV -3. © 201-1 PETERSENDEAN SOLAR 4 ROOFING INC:, ALL RI6HT5 RESERVED, N z Q Q Z CALLE ARROBA PILOT PLAN SCALE: III=20' CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY LAR PV ROOF .IN PANEL 8 METER 4AIN SERVICE �OONNEOT P15CONNECT COMBINER BOX 4 I� IN PETERSENDEAN SmarterRoofs' • Solar Energy • Services 1520 CONTAINER CIRCLE RIVERSIDE, 92509 P: (951) -4 O w.pe ree deon.com GA N5 No. 46811 f G- 4 46 PROJECT NAME: MARTINEZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CITY OF (12) MISSION SOLAR ENERGY MSE295SO5T (12) ENPHASE M250-72-2LL-S22 (240V) DRAWING NOTES: MODULE RATED At. 295W MULTIPLY BY QTY. OF MODULES: 12 ARRAY 5Y5TEM SIZE. 3.54 kW SYSTEM AZIMUTH. 1800 ROOF PITCH. 16°= 4//1/ 12 MOUNTING HEIGHT: 1 -STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LuCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION 15 REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING WH 08/11/2017 PV -4 © 201-1 PETERSENDEAN SOLAR 4 ROOFING INC., ALL RIGHTS RESERVED CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: GALLS AMOBA a X01 m 0D�, � n�Zi O� �cz 90 z 90 C 0NNWT C m WDINER BOX S m Z M Q PETERSENDeEAN' 1820 CONTAINER CIRCLE RIVERSIDE, CA 92509 P, (951) 216-4890 NwNpatareendean.com CA LICENSE No. 4681PI C-10 ! C-48 PRO.ELT MARTINEZ RESIDENCE 77877 CALLE ARROBA LA QUINTA, CA 92253 JOB #37689.00 JURISDICTION: LA QUINTA, CITY OF 11 2) MISSION SOLAR ENERGY MSE295SO5T (12) ENPHASE M250.72-2LLS22 (240V) MAP PLACARD ® 2017 PETERSEN DEAN ROOPINS t SOLAR SYSTEMS, INC. ALL RIBIITS RESERVED N Tile MItT or uN,w.NOR,ao vx or TNex eNOP oRAwiN� D'f A TNIRD PARTY, Tse uNAurwoR,aO uxn SMALL NOLO MAFi4.Lss PeTSRxNOUN ROO'INB . SOLAR SYSTCMS, INC„ IT`D O,RGGTOr[S, OrrlGerts. ABeNTs ANO eMPLOTGSYl. A»IBMs ANO ANY RLLATeD PeRSON9 Oil eN -aq.