Loading...
BMCH2017-022878-495 CALLE TAMPICO Twit D 1 Qu&r(u LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT z UJ BUILDING PERMIT Application Number: BMCH2O17-0228 Property Address: 80209 AVENUE 50 APN: 777010003 Application Description: GARDELL RESIDENCE / (2) HVAC CHANGE OUT Property Zoning: CONDITIIONING=INC Application Valuation: $38,071.00 Applicant: DESERT AIR CONDITIONING INC 590 WILLIAMS ROAD PALM SPRINGS, CA 92264 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C220, C43 License No.: 276586 Date: i" — / % - 1-7 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure'is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044,.Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ' (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Owner: MIKE & JULI 80209 AVE LA QUINTA , Contractor: DESERT AIR 590 WILLIA. PALM SPRI VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/9/2017 E RF�S� NUE NGS, z UJ 50 CA 92253 ^ ' iu N z F O I 0 CONDITIIONING=INC ri, MS RIOAD) C5 t_ �. 1 0 IrM 14:== (760)323-3383 Llc. No.: 276586 WORKER'S COMPENSATION DECLARATION . I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5008762 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. A Date: ^' 9 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE. LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT . IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued.as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building constfuction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposesg// f/S/f i DateyL/'p'"� % Signature (Applicant or A ent Date:. 6/9/2017 Application Number: BMCH2O17-0228 Owner: Property Address: 80209 AVENUE 50 MIKE & JULIE REESE APN: 777010003 80209 AVENUE SO - Application Description: GARDELL RESIDENCE / (2) HVAC CHANGE OUT LA QUINTA, CA 92253 Property Zoning: Application Valuation: $38,071.00 Applicant: Contractor: DESERT AIR CONDITIONING INC DESERT AIR CONDITIONING INC 590 WILLIAMS ROAD 590 WILLIAMS ROAD PALM SPRINGS, CA 92264 PALM SPRINGS, CA 92264 (760)323-3383 Llc. No.: 276586 Detail: (3) HVAC CHANGE OUT - 19.5, 20.5 AND 21.5 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $228.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-426000 $114.00 Total Paid for CHANGEOUT: $342.00. DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) Project Name: 80-209 AVE 50 Date Prepared:!' CF1R-ALT-02-E (Page 1 of 4) 2017-06-08 A. General Information CHR -ALT -02 is applicable to multiple -space conditioning systems contained. within a'single dwelling unit When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name 80-209 AVE 50 02 Date Prepared 2017-06-08 03 Project Location 80-209 AVE 50 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 80-209 AVE 50 Dwelling Unit Conditioned 07 Zip Code 92253 08 Floor Area (ft2) 4800 SCS stem SCS stem. CFA served Number of Space refrigerant i. 09 Climate Zone 15 30 Conditioning (SC) Systems in 3 Location or Area : by this SC ducted containing! t this Dwelling Unit: more than 40 .�,•-�" ! 1 ,r, -_ 'Sr_ I.-, tib -1117 r__ rr- -- I € B. Space Conditioning (SC) System Information{s Ol 02 03 04 �05y + '`• ' 06 07` ? :: 08 �_ �09 10 `Is the SCS In tailing a - "` ° ' T t. C r" SCS stem SCS stem. CFA served system a refrigerant i. Installingg new SC." ,Installing Installing! Installing Identification or Location or Area : by this SC ducted containing! t r '.: 'system ° more than 40 entirely new entirely new Name Served System (ft2) system? component?, components? feet of duets?gig 'duct system,? SC system? Alteration Type System 1 Location 1 2000 Yes Yes Yes No ... No No Altered space conditioning system Altered space System 2 Location 2 .' 1600 Yes Yes Yes ; No No :• ;`'.: No conditioning system System 3 Location 3 1200 Yes Yes Yes } No ; .. No .. No Altered space conditioning system Registration Number: 217-A020193187A-000-000-0000000-0000 Registration Date/Time: 2017-06-08 11:17:45 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-08 11:13:14 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT HVAC) (Page 2 of 4) C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)iDiIb) . This section does not apply to this project. D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 • 02 03 04 .05 `.. 06 07 08.0. 09 10 it 12 Heating ;Cooling System-- Heating Altered Heating Minimum:•a:• Altered Cooling �.i Minimum Required New or Identification System Heating Efficiency • Efficiency;:- Cooling Cooling Efficiency :.• Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type;.i <• Value Type Duct Length R -Value .Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 81 AC cooling SEER 19.5 : Setback section is not section is not components components applicable applicable Central gas All new Central split All new This field or This field. or System 2 furnace heating AFUE 81 AC cooling SEER- 20.5 Setback section is not section is not components +�' ,V 11 a componentsw;^r�r;fit applicable applicable System 3 Central gas All new heating AFUE ! ! Gentral;split e s tAll� newA..,.r x. �coolmg 'ta xSEER I S 21 S . Setback This field or section is not This field or section is not furnace, componerits Y ,81 cw „ AC com onents P 3 *� < �? =) a +. • x, --s applicable applicable Required Documentation: ! CF2R-MCH-01-E - Space Conditioning Systems* - Duct insulation requirement for the new portions of supply -air and return-air.ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF311-MCH-20-H - Duct Leakage Test required when heating or cooling.components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 10% leakage to outside, or seal all accessible leaks. CF2R and.CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. a Heating -only systems and Air Handler'Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with. or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. Registration Number: 217-A020193187A-000-000-0000000-0000 Registration Date/Time: 2017-06-08 11:17:45 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005. Report Generated: 2017-06-08 11:13:14 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 4 of 4) Documentation Author's Declaration Statement 1. I certify that this Certificate offiCompliance documentation is accurate and complete. Documentation Author. Name: Documentation Author Signature: W / / Trefun, Michael rc ae. re rin. Company% Signature Date: Desert Air Conditioning Inc. 2017-06-08 11:17:45 Address: CEA/ HERS Certification Identification (if applicable): 590 Williams Road 5947679/5947729/5947855 City/State/Zip: Phone: Palm Springs CA 92264 760-323-3383 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of.the Business and Professions Code to accept responsibility for the building design or system design, identifled on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials,tcomponents, and manufactured devices for the building designor system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code ofR eg la ions 4. The building design.features or system design features identified onthis Certificat6 of Compliance are consistent wrth the information.provided on'other applicable compliance documents, worksheets, #, �t .-moi f� k- 4 +1 `�. k ; i calculations; plans and specifications submitted to the enforcement agency for'approval with this building permit application. ' ,,i y • 41 51 1 v" )-k :,s w", 9,e , 5. 1 will ensure that a registered copy of this. Certificate of gompliance shall-bt;made.availablewith the bUildingpermtt(s) issuetl forithe;bullding, and made available to the`enforcement agency for all applicable _._ _ inspections. I understand that a registered copy of this Certificate of ComplKanc eis required to be.included with the documentationhebwlder provpdes to the building owner at occupancy. l Responsible Designer Name: f i % Responsible Designer Signature:t �AAS,/ j /-' t-/'r� 7 Trefun, Michael C/�(.ichael ✓re crn Company: Date Signed: i Desert Air Conditioning Inc. 2017-06-08 11:17:45 Address: License: 590 Williams Road 276586 City/State/Zip: Phone: Palm Springs CA 92264 760-323-3383 Easy to Verify FEE ❑� at CaICERTS.com Digitally signed by CaICERTS. This digital signature is provided in order to secure the.content of this:registered document, and in no way implies'Registration-Provider responsibility fc r the accuracy of the inforrm Registration Number: 217-A020193187A-000-000-0000000-0000 Registration Date/Time: '2017-08=08 11•:17-45. HERS Provider: CaICERTS CA Building Energy Efficiency Standards.- 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-08 11:13:14 Schema Version: rev 10/16 Bfn.# City 0f Qutnto BLdkring 8L Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 80-209 AVE 50 Owner's Name:. MIKE & JULIE REESKE A. P. Number. Address: 80-209 AVE 50 Legal Description: Contractor: DESERT AIR CONDITIONING, INC City, ST, Zip: LA QU I NTA, :CA 92253 Telephone: 760-404-7176 Address: 590 WILLIAMS RD--- - 'PmjectDescriptionc ._ _' City, ST, Zip: PALM SPRINGS, CA 92264 INSTALL,(1) 5_TON,,(1.) 4 TON & (1) 3TON Telephone: 760-323-3383 "= S`'' CONDENSER AND COIL State Lie. # : 276586 City Lie'. #: Arch., Engr., Designer u a .' : t', a Address: City, ST, Zip: Telephone: P ;,:� Construction Type: , Occupancy: State Lie.#: r =.r.' ... .'"x ' N Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: CANDICE FORSYTHE' Sq. Ft: #Stories: #Units: Telephone # of Contact Person: 760-323-3383Estimated value of project: $38,071.00 APPLICANT: DO NOT WRITE BELOW THIS LINE ` # Submittal Req'd Recd TRACKING PERMITFEES Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance Title 24 Calc&- - Plans picked up Construction Flood plain plan Pians resubmitted.'. Mechani'm Giading plan tad Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M L H.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"' Review; ready for correctionvissue Developer Impact Fee Planning Approval Called Contact Person AJ.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees