Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0546 (SFD)
P.O. BOX 1504 --�� 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: Property Address: APN: Application description: Property Zoning: Application valuation: Applicant: 13-00000546 81540 BAFFIN AVE. 767-200-998-101 -330762- DWELLING - SINGLE FAMILY LOW DENSITY RESIDENTIAL 1248838 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: JAMES & LINDA LIPPMAN 11766 WILSHIRE BLVD 15TH FLOOR DETACHED LOS ANGELES, CA 90025 t (310)268-8344 Architect or Engineer: 6N LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business a Professionals Code, and my License is in full force and effect. License Class: B 2 License No.: 915336 Datet 9��9 Contracto/ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5,. Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (55001.: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, . and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that.he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY -I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT Date: 8/16/13 . Contractor: -JU L 1013 DBCA INC AUGv P.O. BOX 1482 LA QUINTA, CA 92247 CITY OF LAQ'UINTA (760) 393-5271 FINANCFOE'WT Lic. No.: 915336 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ,I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier TRAVELERS Policy Number YJUB282D7797-12 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if Ishout com subject to the workers' compensation provisions of Section 3700 of the Labor C , I shall rthwit comply wi p ions. Date: $•/`• /3 Applica4:� WARNING: FAILURE TO SECU WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made�to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that 0aboy.tion is correct. I agree to comply with all city and county ordinances and state laws relatingto band hereby authorize representatives of this countyto enter upon the above-mentioned propurpo e . Dat � Signature (Applicant or Age �1- Application Number . . . . . 13-00000546 Permit . . . . . . MECHANICAL LQPERMIT \l Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/CONG <=10 Other struct info . . . . . CODE EDITION 2010 # BEDROOMS 7.00 FIRE SPRINKLERS yes GARAGE SQ FTG 1103..00 PATIO SQ FTG 2113.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 10919.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 3593.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 4037.50 Plan Check Fee 2624.38 Issue Date . . . . Valuation . . . . 1248838 Expiration Date . . 2/12/14 Qty Unit Charge Per Extension BASE FEE 3539.50 249.00 2.0000 ----------------------------7----------------------------------------------- THOU BLDG 1,000,001 - UP 498.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 559.98 Plan Check Fee 140.00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/12/14 Qty Unit Charge Per Extension BASE FEE 15.00 14512.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 507.92 1103.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 22.06 1.00 15.0000 ---------------------7------------------------------------------------------ EA ELEC TEMPORARY POWER POLE 15.00 Permit GRADING PERMIT Additional desc ... Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 2/12/14 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . . . . MECHANICAL LQPERMIT \l Application Number 13-00000546 Permit . . . MECHANICAL 15.00 41.00 6-.0000 EA PLB FIXTURE Additional desc . . 15.00 16.00 6.0000 EA PLB ROOF DRAIN 96.00 Permit Fee . . . . 320.50 Plan Check Fee 80.13 Issue Date . . . 15.00 Valuation 0 Expiration Date 2/12/14 1372sf BOWLING + 3593sf LIV 2ND) R-3 Qty Unit Charge Per Extension **PERMIT DOES NOT INCLUDE BLOCK WALLS, BASE FEE 15.00 9.00 9.0000 EA MECH FURNACE <=100K 81.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 7.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 115.50 13.00 6.5000 EA MECH VENT FAN 84.50 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . Additional desc Permit Fee Issue Date Expiration Date PLUMBING 451.50 2/12/14 Plan Check Fee . . 112.88 Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 41.00 6-.0000 EA PLB FIXTURE 246.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 16.00 6.0000 EA PLB ROOF DRAIN 96.00 5.00 7.5000 EA PLB WATER HEATER/VENT 37.50 1:00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 20.00 .7500 EA PLB GAS PIPE >=5 15.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 14,512 sf 2 -STORY SFD. (9547sf LIV 1ST + 1372sf BOWLING + 3593sf LIV 2ND) R-3 OCC. TYPE V -B CONSTR. W/ FIRE SPRINKLERS. 2010 CODES. 2013 DIF. TUMF. **PERMIT DOES NOT INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, BBQ'S and DRIVEWAY APPROACH** ARCHITECT: STEPHEN A GIANNETTI C18467 Deferred Submittal Item: Glass Railings Pre engineered system to be reviewed by Engineer of Record and submitted to Building Div. for Approval prior to installation. --------7------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 2622.10 BLDG STDS ADMIN (SB1473) 50.00 LQPERMIT Application Number 13-00000546 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF COMMUNITY CENTERS -RES 129.00 DIF CIVIC CENTER - RES 942.00 ENERGY REVIEW FEE 262.44 DIF FIRE PROTECTION -RES 433.00 DIF LIBRARIES - RES 344.00 DIF PARK MAINT FAC - RES 40.00 DIF PARKS/REC - RES 2048.00 STRONG MOTION (SMI) - RES 124.88 TUMF: RESIDENTIAL 1837.44 DIF STREET MAINT FAC -RES 116.00 DIF TRANSPORTATION - RES 2842.00 Fee summary Charged- Paid Credited Due ----------------- Permit Fee Total ---------- 5384.48 ------------------------------ .00 .00 5384.48 Plan Check Total 2957.39 1000.00 .00 1957.39 Other Fee Total 11790.86 .00 .00 11790.86 Grand Total 20132.73 1000.00 .00 19132.73 LQPERMIT P.O. BOX 1504 Building�V78-495 CALLE O e Address f/ Y I Lr LA QUINTA, CALIFORNIARNIA 92253 JQ Me6 a-- L4 N Ph L-+ Pavho1J Mailing n� I ,1 Address i" 7(G O t S r,° UI V D i s -f[ City ZipTel. Ld les -S Contractor ts�derc. -ou i ers GSL r(;rm i 1 - Address. CityZip Tel. LA -7(40' State Lic. City & Classif. i 5� "�. Lic. q, Arch., Engr., Designer Ula/7h fe q__ 1A764 Address Tel. 1101520 /3 2 / D 5e?ri / L3L� : '-� /q City ZipState to 5 �/1 /es q )0 Lic. # ' LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing wit Section 7000) of Divisio 3 of the Business and Pr s C e d m license is in tut f rce a effect. o- SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031 S, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason .1, Date Owner !'t` WORKER'S COMPENSATION DECLARATION �- . '. I'hereby Aitm,that I have a certificate of consent to self -insure, or a certificate of Worker's ?'Compensation Insuranceyor a certified copy thereof. (Sec. 00, Labor Code.) Policy Nb. .Company} C C*Zopy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT Z :7v/3-5�� APPLICATION ONLY BUILDING: TYPE CONST. OCC. GRP. A.P. Number 7622 -7/0 -o-3 y Legal Description C Project Description Jff1 /1"-' A -'IVDU VZ4IdeAli? a Sq. Ft. j `� .2 UnitDw. Size f :J Stories Add ❑ Alter ❑ Repair ❑ Demolition ❑ s _fC/vow Estimated Valuation /O 4W&11;* ODD PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL CONTACT INFORMATION NAME: PHONE: ZONE: BY:_ Minimum Setback Distances: Front SE Rear Se Side Str Side Sel FINAL DATE Issued by: _ Validated by Validation: or Center Line f m R o2116n?g Se ack from Center L ' ck fron ffj , INT,�DEPT "� ` Date Permit— YELLOW = APPLICANT PINK = FINANCE Cog h'i?fi I Valley Unified School District This Box For District Use Only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760):398-5909 — Fax (760) 398-1224 AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND: AMOUNT: DATE: RECEIPT: - CHECK #: FNIT.ALS .. CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Madis� on Club Date: August 8, 2013 Owner's Name: James.& Linda Lippman Phone No. Project Address- 81'540:BaffinAvenue, LAQuinta, CA Project Description: Single Family Dwelling APN: 767-710-034/767-710-035 Tract #: Lot #'s Type of Development: Residential XX Commercial Industrial• Rt rN Total Square Feet of Building Area: 14,512 Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes t is statement un penalty of perjury and further represents that he/she.is authorized st on behalf of the owner/developer.. /41J CI2413 Dated: August 8, 2013 Signature:—zzv c OM IQF�4 Q(/ Ft*o'�j NT SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) _. Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17.620 65995 Approval Prior to 1/1/87 Requirement .. N Number of Sq.Ft. 14512 Pursuant to AB 181 any. room additions or enclosures of 500 . ft. or less are exempt from developer fees. Any mobile Amount per Sq.Ft. $3.20 sq homes being relocated within the same school district :s Amount Collected. $46438.40 jurisdiction are exempt from developer fees._ Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director. of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the.validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days.starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. Iv1V:c/mydoc/devfees/certificate of conMpliance form updated 3-2007 11/2010 CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which canno_tbe processed will be returned to applicant. Date: 15 / 9 / 13 Developer: /SCS [/P n4 6o I. �a��S t Gi./ / 6I'✓V % Ota Tract No.: Tract Name: (`(( Lot No.(s): MIA j /Q1 Address(s):4 tip 4A 4&47 Phone Number: ( 1/,2d) The following are the requirements for Public Works Clearance to authorize issuance of a �tA p om the Building &Safety Department: ��, !!! •:• CUSTOM HOMES: PROVIDE ITEMS #2. #3, #4, #5 & #7 BELOW ED •3 TRACT HOMES: .PROVIDE. ITEMS #1, #2 #3 & #5 BELOW COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 #5 & #7 BELOW MAY 172013 WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW CIN COMM(1� OF LA QUINT,q 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for buildi4i/�[i allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of.current a /N. T If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be.provided. %} Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. P�[� Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. L� Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. PrA-/n Pt.4AI /rvpt-4CZ Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development Ian 6. Attach supporting documentation for wall Ian, monument sign, grease trap or special facility installations. 1v PP 9 P 9 9 P P Y wrr,V/-Vp U. L& Ul Complete and sign the attached water quality management plan (WQMP) exemption form, if -applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanCheck/m search aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. Recommended by: Date: Public Works Distribution: ( Z) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: TXhec:dists - Forms & Applications\Forms d Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc Coachella Valley Unified School District This Box For District Use only 83-733 Avenue 55, Thermal, CA 92274 DEVELOPER FEES PAID (760) 398-5909.— Fax (760) 398-1224 AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/MD: AMOUNT: DATE: RECEIPT: CHECK#: FMT1ALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Jim Lipman Date: June 2, 2014 . Owner's Name: Phone No. Project Address: 81-540 Baffin Ave., La Quinta, CA 92253 Project Description: Additon While Under Construction APN: 767-200-998-101 Tract #: Lot #'s: 10113/10213 Type of Development: Residential . . .XX! Commercial Industrial. Total Square Feet of Building Area: 189 SQ. FT. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.. Dated: 6ZA/A0/V Signature: � ` i SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code. Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. _ 189 Amount per Sq.Ft. $3.20 Amount Collected $604.80 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Signa re: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMEXT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires thalAhivDistrict provide (1) a written notice to the project appellant, at the time.of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of.issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/nryd6csJdevfees/certificate ofcompliance form updated 3-2007 11/2010 l . WEDDLE SURVEYING MAPPING, INC. Boundary- Construction -Topographic -Aerial Surveys -ALTA Surveys -GPS- Consulting August 8, 2013 Mr. Timothy R. Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253-1504 Re: Pad Grade Verification City of La Quinta LIPPMAN RESIDENCE Parcel "A" Parcel Merger No. 2013-520 81-540 Baffin Avenue MADISON CLUB APN 767-710-034,035 Dear Mr. Jonasson: We have performed a field survey to determine the vertical location of the Building Pads for the above referenced project. The elevations observed are as follows: PAD (DESIGN) PAD (AS -BUILT) 987.0' 987.0' PAD (DESIGN) PAD (AS -BUILT) 988.0' 988.0' PAD (DESIGN) PAD (AS -BUILT) 986.0' 986.1' PAD (DESIGN) PAD (AS -BUILT) 985.0' 985.0' PAD (DESIGN) PAD (AS -BUILT) 983.67' 983.7' PAD (DESIGN) PAD (AS -BUILT) 984.0' (983.75') 983.8' These field observations are in substantial conformance with the Precise Grading Plan prepared by McGEE SURVEYING, INC., dated 7/1/13, and the building Pad horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, WE LE SURVEYING MAPPING, INC. David L. Weddle, President L.S. 5570, exp 09/30/13 P.O. Box 10418 • Palm Desert, CA 92255-0418 77-725 Enfield Lane, Ste. 140 -Palm Desert, CA 92211 - 760.360.5570 E -Mail: WedSzirv@ool.com -Fax 760.360.5573 • TICOR TITLE ORIVERSIDE RECORDING REQUESTED BY Ticor Title Company of California AND WHEN RECORDED MAIL TO: James Lippman, Trustee Linda Lippman, Trustee 317 N. Rockingham Los Angeles, CA'90049 ORDER NO.: 79178-35-MS2 ESCROW NO.: 00079178-035 �YGI 0� 0 THE UNDERSIGNED GRANTOR(s) DECLARE(s) 13unincorporated area X the City of La Quinta DOC # 2012-0317047 07/09/2012 03:11 PM Fees: $31.00 Page 1 of 3 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder —This document was electronically submitted to the County of Riverside for recording— Receipted by: QHENSON THIS LINE FOR RECORDER'S USE GRANT DEED Documentary Transfer Tax is $4,675.00 City Tax is S 0.00 X computed on full value of interest or property conveyed, or O full value less value of liens or encumbrances remaining at the time of sale Parcel No. FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ,lames J. Irwin, Trustee, The Irwin Family Trust dated December 22, 1987 and Elizabeth A. Irwin, Trustee, of The Irwin Family Trust dated December 22, 1987 hereby GRANT(s) to James Lippman, Trustee and Linda Lippman, Trustee, of The James and Linda Lippman 1998 Trust the following real property in the City of La Quinta County of Riverside, State of California: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF Dated: June 21, 2012 The I I iI ted 1) C11 trier 22. 1987 lances ,I. � in, 'I'r ec Elizabeth A, Invin, T rustee STATE OF CALIF N A pp COUNTY OF ��a/de SS: On JUAX, /- ./ before me,' v C , a Notary Public, personally appeared is 17J"t41,&A1jd ZZZAdeW who proved to me on the basis of satisfactory evidence to be the person(s)whose name(s)//are subscribed to the within instrument and acknowledged to me that hefshe they executed the same in hiAwr/their authorized capacity(ies) and that by his herhheir signature(s)on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hWd and official seal `� j d CIX FM L. 943tII0— 2 o COMM. #1943282 Z Signature z Notary Public . California o Riverside County tt Comm. Ex ires A . 4, 2015+ MAIL TAX STATEMENTS AS DIRECTED ABOVE Page I GRANTDEE t. DOC ## 2012-0317047 Page 2 of 3 07/09/2012 03:11 PM NOTARY SEAL Under the provisions of Government Code 27361.7, 1 certify under the penalty of perjury that the Notary Seal on the document to which this statement is attached reads as follows: Name of Notaryt 0 VC k L • C 000 Commission #: Date Commission Expires: County where Bond is filed S PLACE OF EXECUTION: San Bernardino DATE: 2 r SIGNATURE: (_U____V ons• DOC # 2012-0317047 Page 3 of 3 07/09/2012 03:11 PM Escrow No.: 00079178 - 035 -Sharon Elkins EXHIBIT "A" Parcel A: Parcel I of Parcel Map No. 36300, in the City of La Quinta, County of Riverside, State of California, as shown on Map recorded in Book 231 of Parcel Maps, Pages 83 and 84 of Parcel Maps, in the office of the County Recorder of said County. APN 767-710-034 Parcel B: Parcel 2 of Parcel Map No. 36300, in the City of La Quinta, County of Riverside, State of California, as shown on Map recorded in Book 231 of Parcel Maps, Pages 83 and 84 of Parcel Maps, in the office of the County Recorder of said County. APN 767-710-035 For APN/Parcel ID(s): Page 2 GRANTDEE File Edit Commands Help U!!G/1RD'1U3UC CFC70.1. Application 13-00700546 ► �- 2622. 1U Bonds Property Information Contractor escrow Address: 81.540 BAFFIN AVE Fees 4/29/201.3 it } LA QUIWA. CA 92253 Q Global balance due Location ID: 54328 Inspection history Owner name: EAST OF MADISON LLC' [] taiscelianecus informar APN: 767-2,00-996-101 -330762- lyames Alternate I0: 2 62. 44 <? Per-mits Zoning: RL LOW DENSITY RESIDENTIAL Plan Tracking [� RFce' tG j Application Information �- 2622. 1U Application desc: i,IEAI SIGNLE FAMILY UNELLING ;-ri i Application status: IN PLAN CHECK Status Date: 4/29/201.3 it } '! Application tvpe: (MELLING - SIN61-E FAMILY GEI-- Apptication date; 4/29/2013 J Valuation: 114t�838 _.: _......... _....-.. 442.00 M Square footage calculat Q structures t Valuation calcuiations 2622.10 _...__..�.._..._.._...... Print l Cancel i -J( Exit Refresh Land Inquiry Documents AI . . ART TE PUBLIC PLACES -RES 2622. 1U PA BLDG SIDS LDi711i (SBI.473) 50.00 50.00 CC- IIF COMMUNITY ?7EMTERS-RES 129.00 129.00 C1 P. IF .0?v TC CEdiTEr - F=S 442.00 992.00 E E RG'_ E-VIMO FEE 2 62. 44 262.44 I F1. L+.IF FIRE. PROTECTION -RES 433.00 433.00 1 L1 DIF LI=RARI S - RES 344.00 344.00 PC PLAN CHECKFEES' 2624.38 1624.38 600o0o H00100 CHECK FFES .140.00 140.0. 0IJ00 100 E01 G0 PC PLAN CHECK FEES 0Q.13 100.13000000 .. IA01 00 PC - PLAN r:HEf'i:: FEE:, .= 1.�-� .$3 112.85 ... 000000 P01 00 7 + PF °EAi°'IT" FEES 4037.50 403"?.50 1000000 800100 FF -b ERM IT FEES 55 1. 5S^.9 i.. 000000 E01 00 I PF PER11IT Fr ES 15.011 15.00 00'00010 CP 00 PF PEP?sI^ F2E� 320.50 320.50 ... 00L000 :d01 00 PF 66Rjo11+ FEES 451.50 451.50 000000 POI 00 t PY, IDIF PARK N1AINT AC - RES 40.00 4 .O. UO _. .. .< DIF PARKS/REC - 2?8 Z048. 00 204x; .00 S1 ST LING MOTION (SP1I) - RE15 124.'0' 124.68 T.'. mri-lr. RES1D-tITI_Aii1837.94 1837.44 T.1 DIF STREET MAi.NT FAC -RES 11x.00 1.1.6.00 i II TRAIiSPrI TATEO?d - RES 2842.013 2542.00 k Taa.I� 20i: ?3 i^1.32 THIS AREA THIS PAGE ADDED TO PROVIDE ADEQUATE SPACE FOR RECORDING INFORMATION DOC # 2013-0256361 05/30/2013 02:32 PM Fees: $21.00 Page 1 of 5 Recorded in Official Records County of Riverside PLEASE COMPLETE THIS INFORMATION Larry W. Ward Assessor, County Clerk &Recorder RECORDING REQUESTED BY AND WHEN RECORDED MAIL TO: "This document was electronically submitted CITY OF LA QUINTA to the County of Riverside for recording- Attn: CITY CLERK DEPT Receipted by: ARIBAC 78-495 Calle Tampico La Quinta, CA 92253 SPACE ABOVE FOR RECORDER'S US.E, ONLY ..CERTIFICATE OF PARCEL MERGER NUMBER 2013-520 APN 767:710=034 and THE GRANTOR(S) HEREIN DECLARE(S) APN-767-710-035 DOCUMENTARY TRANSFER TAX 1S $ 0 CITY TAX IS $ 0 ecomputed on full value of property conveyed, or computed on full value less valine of liens or encumbrances remaining at time of sale, []Unincorporated area:FX City of La Quinta THIS AREA THIS PAGE ADDED TO PROVIDE ADEQUATE SPACE FOR RECORDING INFORMATION RECORDING REQUESTED BY CITY OF LA QUINTA When recorded, return to: CITY OF LA 00iNTA CITY CLERK 78-495 CALL_E TAMPICO LA QUINTA, CA: 92253 [)00 #2013-0256361 Page 2 of: 05/30/2013 02.:32 PM THIS AREA FOR RECOROER'S USE ONLY RECEIVED AUG I�2 2013 COM N OE QUINTA ELOPMENT CERTIFICATE OF PARCEL MERGER NO. 2013-520 ...RECORD OWNERS EXISTING PARCELS (Assessor Parcel Numbers) JAMES & LINDA LIPPMAN 1998 TRUST 767-710-034; 767 -710 -O35 - LEGAL DESCRIPTION OF MERGED PARCELS z v See attached - Exhibit "A" and Exhibit "B' c SIGNATURE(S) OF RECORDED OW R(S) (Must be Notarized), < c Piint Name/Title; JAMES LIPPMAN/MEMBER Signature:. Fes,' U O Punt Narnelrille. Si natwe: ..._ ... .._.. .... . U , Print Name/We: St nature: > Print NameTtle: .0 Y o O This Certificate of Parcel Merger reflects Parcel Merger No. 2013 - 520 as approved by the City of La Quinta. a E Date: Q NOTARY ACKNOWLEDGEMENT r STATE OF CALIFORNIA ) COUNTY OF . 4 V 47-7 <I eJ eS On Ja, '1-5: before me, d ct i)I S �- ��E�<<..(�1 rr�.21 � 4/2"T nit .✓�r,/�/<C .� . (Date) (Na'me and lifle of officer) personally appeared . 0 0 nt e J (Natne(s) of signer(s)) who proved to me on the basis of satisfactory evidence to be the peirson(s) whose name(s) is%are subscribed to the within instrument and acknowledged to me that he/sheMey executed the same in his/hedtheir-authorited capacity(ies-), and that by hislhediheir signature(s) on the instrument the person(s), or the entity upon behalf of which the persons)* acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the Sate of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal MELODY SALAZAR Com A► 1 9664 -+ Notary Public PuWk - CaIltorn{i Los Angeles County Nota Public Los Angeles Count Commission 411929664, expires 3/21/2015 L State of California ) ) County of Riverside ) DOC #2013-0256361 Page 3 of 5 05/3012013 02:32 PM _� _.:....... On May 30, 2013 before me, SUSAN MAYSELS, Notary Public, 'personally appeared TIMOTHY:. R... JONASSON who proved to me on the basis of satisfactory evidence to be the person whose name is subscribed to the, within instrument, and acknowledged to me .that, he executed the same in his authorized capacity, and that by his signature on the instrumen't..thd person, or the entity upon behalf of which the person acted, executed the instrument. I 'certify under PENALTY OF . PERJURY under the Laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. sosAti MAY8fl8. ^, Commfstlon 0 2017258 Notary Publk - CAINornis 1.L , Rivarsida County .. Signature. M thrift. Ex irl r 13, 2017 Susan Maysels Commission //2017258, expires 4/13/2017 (seal) Riverside -County DOCUMENT: CERTIFICATE OF PARCEL MERGER #2013=520 for APNs 767=710=0344 and 035; owner: James & Linda Lippman 1998 Trust:. WC #2013_0256361 Page 4 of 5 05/30/2013 02:32.PM A SHEET I OF I EXHIBIT CERTIFICATE PARCEL MERGER 2013-520 EXISTING PARCELS' RECORDOWNERS -ASSESSOR PARCEL NUMBERS & LINDA LIPPMAN 767-710-034 & 767-710-05 �JAMES MERGED PARCELS 1 & 2, P.M.B. 23I183-84 PARCEL -vA 9 IN THE CITY OF LA` QUIN TA, COUNTY OF RIVERSIDE, S TA TE OF CALIFORNIA, IN SECTION 10, T6S, R7E, SBM.: PARCEL I OF PARCEL MAP -36300, AS RECORDED IN BOOK 231 OF PARCEL MAPS AT PAGES 83 THROUGH 84, RECORDS OF RIVERSIDE -COUNTY, WMD? WN PARCEL 2 OF SAID PARCEL MAP 36300 CONTAINING 80,869 SF 1.86 AC.) MORE OR LESS SUBJECT TO ALL COVENANTS, CONDIRONS, RESERWRONS. RESTRICTIONS RIGHTS OF VIA Y, EASEMENTS, OR EXCEP FIONS'OF RECORD, IF ANY. WAYNE A. Mc GEE DATE P.L.S. 5479 EXP. 910114 \OxAp U L A lyn s� - A. Mcc<,\ NO. 5479 Exp. 9/30/14 S9TF OF CAL DOC #2013-0256361 Page 5 of 5 05/30/2013,02:32 PM 0 TE. E MAY B£ EASEMENTS OF EXHIBIT nB n THIS PLAT WAS PREPARED FROM RECORD DATA AND ECORD DELINEATED AND REFERENCED Ql DOES NOT REPRESENT A SURVEY OF THE PROPERTY V THE UNDERLYING MAP, OR THERESHOWN AY B£ EASEMENTS WTHIN THE AREA CERTIFICATE OF HEREON. THIS MAP HAS BEEN APPROVED 7D C3 UPON THE EXPRESSED CONDITION THAT BUILDING FING ADJUSTED THAT ARE NOT SHOWN V THIS DOCUMENT THAT COULD PARCEL MERGER 2013-520 PERMITS SHALL NOT BE ISSUED FOR ANY DEVELOPMENT "NECESSARY YCUMB£R SAID PARCEL HEREIN. WTHIN THIS ADJUSTMENT PLAT UNTIL �Q _ DEDICATIONS, IF ANY, HAVE OCCURRED. 60 0 30 60 1 inch = 60 it. TRACT ND. JJ076-1 MB 388/57-79 GOLF COURSE 3 0 2 E A, ,yl "vp "'LC` CURVE EASEMENT NDIES �QyC� F<" o Ql IND/GATES 12.00 FOOT MIDE EASEMENT RESERVED TO DRAINAGE 65.00 72'35'30' C2 THE OWNERS FOR LANDSCAPE AND PURPOSES 7D C3 PER TRACT N0. 33076-2, M.B.' 393/61-80 N0. 5479 Exp. 9/30/14 Q INDICATES 22,00 FOOT WIDE EASEMENT TO THE CITY OF LA QUINTA FOR PUBLIC U7ILITY PURPOSES PER TRACT �Q NO. 33076-2, M.B. 393/61-80 T TF OF k F �R� INOICA7ES 22.00 FOOT WIDE EASEMENT TO IMPERIAL IRR- CAL IGA710N DISTRICT FOR UTILITY PURPOSES PER TRACT NO. 33076-2, M.B. 393/61-80 LOT 0" TRACT NO. 33076-1 MB 386/5777Y GOLF COURSE PARCEL l PARCEL MAP 36300 . PUB 231/83-84 A.P.N. 767-710-034 e ,P 1 LOT LINE TO BE DELETED PER THIS MERGER P Q Z PARCEL 2 PARCEL MAP J6J00 0 PUB 231/83=84 A.P.N. 767-710-035 C2 Ton -4692 A=34.4 ;'90 R-15 X04• N824157"W. 17S., LOT 103 TRACT NO. 33076-2 MB ,393/61-80 A.P.N. 767-710-OT6 CURVE TABLE CURVE LENGTH. RADIUS DELTA Cl 82.35 65.00 72'35'30' C2 22.95 150:00 8'46'01' C3 67.97 150.00125-5743' 4, Ai / BAFFIN �10� AVENUE PRIVATE S7REET PLAT- CITY OF LA O1llNTA PREPARED BY.• WA YNE A. MccGEE DA TE I C Iia 70 APPLICANT JAMES & LINDA LIPPMAN C/0 McGEE SURVEYING INC. 45-100 GOLF CENTER PKWY, STE. G INDIO, CA 92201 LOT 100 TRACT NO. - 33076-2 MB 393/61-80 A.P.-N. 767-710-013 LEGEND EXIST. L07S LINE TO REMAIN LOT LINE TO BE DELETED Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 V Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 5/1/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status We Wood Framed R-21 10,006 New Door Opaque Door None 48 New Slab Unheated Slab -on -Grade None 11,943 Perim = 978' New Roof Wood Framed Attic R-38 10,902 Radiant Ban-ier New FENESTRATION U.Exterior Orientation Area(ft`) '.'Factor SHGC Overhang Sidefins Shades Status Left (S) 75.6 0.490 0.26 none none Bug Screen New Left (S) :;, 40.0 4` —0.290, .wo,, 0.28,..none, ,.a,wownone Bug-Screen�+�„ New Front (E)f,'r t 91.8 `'090'` 0.28�none ;'none _. Bug Screen;, New Rear (I'Mr3 X27,3:2 jJ7„ 0.'450 0 2430.'0_ _Ltnone,s. r'BugScreen ,_ -�,: New Right (N) 1,,196'0 % 3 0.450 t'. �, .. 0'24 ','n ne °” `� none ;Bug Screen,....,r�y"t* New 0 Front E 654.0 5. 0.350' O ,- _. 0 42 none; rs none Bug Screen g_rr r.4New Front (E) ? 1,036 5 0.450 '0.24 6.0 none Bug Screen New Left (S)^'t� 149.1 jTl` 0.350 0.42 none none Bug Screen New Left (S)� , 135.2 0.450 0.24 none none Bug Screen New Rear (VV) 392.1 !+ 0.480 0.56 14.0 none Bug Screen New Rear (IM 459.7 0.450 0.24 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating - Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Conditioned--., 8.0 New HVAC 2 Ducted Ducted Conditioned �; d ')'� �,'� 8.0 New HVAC 3 & 4 Ducted Ducted Conditioned8tJ;1 4 X8;0 New WATER HEATING'ow"V_rA_�j Ot . Type Gallons Min. Eff iDistribution�P � .7 DE,Ar Status 3 Large Gas 100 0.80 All Pipes Ins ` (_'()N.STn,�'v lNew l oAr, � ION /rl EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 201405-01715:56:32 /D: --- Pae 1 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/1/2014 Electronically Siqned at Ca10ERTS . com by Tammv .Tenki na fni , A,-,, PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status FENESTRATION U. Exterior Orientation Areae) t Factor SHGC Overhang Sidefins Shades Status Right (N) 135.2 0.450 0.24 6.0 none Bug Screen New Left (S) .130.1 �^_-0.290,„�w, 0.286.0.0, .,none BugsScreen; New Left (S) . { . " . z. f 35.9 " lio * -fir. �V � r - x� X0.290 0 28i l?none none,,_ _ �.) ` B~ug Screen ,;; New Left (S)rr f,128 3 a " ,- 0.4450 B _ 0. 2�64 -New (V19 .0i ( 70 .. _ �J;(_VRear , eV Bug -Screen a *_ANew 0. Right(N) ,135 2,_ 0.450"„(0.24±r none x none;:Bug+Screen*i�r! New Front (E) 169.5 0.'450.? - ..--'icn ti. ` 9:^'n ry'-r." -.. 0.24"none '�� none Bug Screen New Front(E). " �, 112.5 +. 0.490 0.26 none none Bug Screen New Front (E) r `. 35.7 0.490 0.26 6.0 none Bug Screen New Left (S) 6.4:r 0.480 0.56 6.0 none Bug Screen New Left (S) 176.6.,1 ` 0.480 0.56 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump " 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Conditioned 8.0 New HVAC 6 Ducted Ducted Conditioned 8.0 New HVAC 7 Ducted Ducted Conditioned r r`�. �,� 8.0 New WATER HEATING / "" r r or Ot . Type Gallons Min. Eff Dist ibo LA /ut n'G ,�QuIAI-ii-, Status r Ufa CnA,,; IIIU C/it�1Ar �r EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01T15:56.32--- ID—.- Page 2 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 Ex RS"Pr vid`C-a1IERTS, Inc Electronically Filed by Tim Scott and Authenticated' at Ca10ERTS'com - 5/1/2014 Electronically Siqned at CalCERTS.com by Tammv Jenk;na (ni.,a,-,, PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name ' Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® •Yes ❑ No HERS Measures --If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features --If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity f Features see Part 2 of 5 Status FENESTRATION j U- Exterior Orientation Area(ft`) J Factor SHGC Overhang Sidefins Shades Status Rear (W 209.0 . 0.450 0.24 10.0 none Bug Screen New Rear (V19 60.6—0.490yr. 0.26 10.0,.,,,none *,,,,,,,,..Bug.Screenp**,... New Rear(NJ�'� 405.6 ',0.•p450j" 1 ;0.24„6.0'° none -1 a, Bug Screen,"' New w 1�� = " , r� w”' } A�... tar .,; "0*7� y • 4 t HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 8 Ducted Ducted Conditioned 8.0 New HVAC 9 Ducted Ducted Conditioned._ 8.0 New l ellr z`-�--.,� WATER HEATING B[,T��In �1z Q(` Qty. Type Gallons Min. Eff Distribution& SAFF�,T� Status 1 DATE • �vr� EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01715:56:32 �l©:�_ Page 3 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 -HERS Provider:-a10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 5/1/2014 Electronically Siqned �at Cal CERTS.com by Tammv J—ki— Ini,,o,-,, n,,;i,ve, r�i;a % .i, i•,,,, PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of justification the special and documentation submitted. The DHW System Bradford -White Corp. M-1-100TON is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Covered Slab Floor, 3.500" thick at Maid Quarters • 5 HIGH MASS Design - Verify Thermal Mass: 895.0 ft2 Exposed Slab Floor, 3.500" thick at Maid Quarters The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 280.0 ft2 Covered Slab Floor, 3.500" thick at Kitchen & Dining HIGH MASS Design - Verify Thermal Mass: 1,175.0 ft2 Exposed Slab Floor, 3.500" thick at Kitchen & Dining The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a sep,;rate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 3,377.0 ft2 Exposed Slab Floor, 3.500" thick at living The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se ;rate thermostat.' In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 944.0 ft' Covered Slab Floor, 3.500" thick at Master HIGH MASSr: �D'esign- Verify Thermal Mass: 346:0 ft'_Ezpptosed Slab Floor, 3.500 "thick atyMaster _ The HVAC System HVAC 6 must,serv'eionly Sleeping Areas The non-closable'area°between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition, the air flow requirements and fan watt draw re Ne ants in Residential Appendix' RA3.3 must be met. HE REQUIREDy VERIFICATIONS °'` "° k 'Nw-. "'- Items rn,tlils secflon require field 4esting and/or verlflcaUon'by,a certifled';FiERS Rater. receive a aTFieiinspectormust con leted•CF=4R form for each of the measures listed below for final to be iven. ' The Cooling Systemi Carrier 25HNS9241FE4ANB003 includes credit fora 13.5 -EER A certified HERS rater must field verify the installation of the correct Condenser. f j The HVAC System HVAC 1 includes -credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. n i The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. r___ The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy m not°excel—ed-0:58,w/cf�m.� pay The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge ora Charge 1ndicatorD.isp/ay. _. ' r �� �a f LJEA Compliance credit for quality installation of insulation has been used. HERS field verification is required:, ` L) Fop P0v�r' The HVAC System HVAC 2 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. `AViceitified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. n A T_ ' UU i ioN By EnerqvPro 5.1 by EnemySoft User Number 6712 RunCode: 2014-05-01T15:56:32 ID: �'�_ Pa e 4 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 5/1/2014 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 890.0 ft2 Covered Slab Floor, 3.500" thick at Guest 1 & 2 HIGH MASS Design - Verify Thermal Mass: 450.0 ft2 Exposed Slab Floor, 3.500" thick at Guest 1 & 2 The HVAC System HVAC 7 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,370.0 ft2 Covered Slab Floor, 3.500" thick at Play Room Bowling HIGH MASS Design - Verify Thermal Mass: 286.0 ft2 Exposed Slab Floor, 3.500" thick at Play Room Bowling The HVAC System HVAC 8 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 832.0 ft2 Covered Slab Floor, 3.500" thick at Theater The Roof R-38 Roof Foam includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED, VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater The' inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 3 & 4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 3 & 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification -and diagnostic testing is required to verify that duct leakage meets the specified criteria. I The Cooling System Carrier 25HNS960/FE4ANB006 includes credit for a 12.5 EER Condenser. A' certified HERS rat6i_must-field verify the installation of the correct Condenser. The HVAC System HVAC 5 includes credit for Verified Fan Energy. Measured Fan Energy may not exceetl'0.58 w/cfm. - .-. A The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicat6fiDisplay. t tr r i �'01VS7-lei rr,'© TE r- r JUN LEnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2014-05-01T15:56:3i`i ]D: IJ N Page 5 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provide RTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at CalCERTS.com by Tammv Jenkins (nisenvery a,„lA— PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special •ustification and documentation submitted. - t , i M'^�-'45f+'�.�'F'.a ', J�+Y1.a[i.f Ri, ..N1 HERS':REQUIRE)3iVERIFICATION ''-'.Items Items rn tH' sect on;requlre field testing d%or venficatlori?by a certifiedfHERS Rater, iThe lnspectorYmust receive a Com leted CF -4R form foreach of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. - The HVAC System HVAC 6 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 6 has Ducts, Plenums and the HVAC unit located totally within Cb'nditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. / �Mmu /A The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is.ie&V—W6d:toYverify that duct leakage meets the specified criteria. �� ®�o 7 The Cooling System Carrier 25HNB96&FE4ANB006 includes credit for a 12.5 EERCondenser-JAfceitified HERS'ibter must field verify the installation of the correct Condenser. vIVS %'R� ;0 Ir EnemvPro 5.1 by EnemySoft User Number. 6712 RunCode: 201405 -01T15:56:32 ----,ID: ” / Page 6 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: Cal-CERTS, Inc r . s Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at CalCERTS.com by Tammv Jenkins (niernvery Ru;lliara rniifn—i n) ciii,�n,e PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 7i/l/2014 ❑ Multi Family ❑ Existing+ Addition/Alterati ate SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. .rt_r r' •f S }v,as' t."" air ' n. rr S s i HERSREQUIRED VERIFICATIOIVb�T' `F�` a i Items In tFils section,requlre,field testing a d%or verificatlon'by.a certifle_ d!HERSiRater.,Thelinsreceive a _ pector must completed CF -4R form for eacli of the measures listed below for final to be given. TheH� HVAC System -HVAC 7 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. f Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 7 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure Willow of the HVAC System. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB924/FE4ANB003 includes credit for a 13.5 EER Condenser. A certified HERS rater must held verify the installation of the correct Condenser. The HVAC System HVAC 8 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 8 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. / 01? Compliance credit for quality installation of insulation has been used. HERS field verification is iequired. C) The HVAC System HVAC 8 has Ducts, Plenums and the HVAC unit located totally within Conditioned--space.0ALeitifigd.HE RS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. l _ �'P� � x l /Y The HVAC System HVAC 8 includes credit for verified adequate airflow. A certified HrrateO must diagn6sticallyihiea§ure-airtlow oPthe HVAC �'vI ur System. /� V's�- a./ � L22 EnemyPro 5.1 by EnemySoft User Number.` 6712 Run Code: 201405-01 T15:56:32 ID: / Pae 7 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provide ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Siqned at Ca10ERTS.com by Tammv •7enkina Mi4rnu -., n„ilrl r,i;f... ;�i C111—A PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. t R . k. iT F. is ..�....4.. z •.l F �fS j �iR' a 1.dr 1�K*� ]i1 tf �ii A '4..� ^•F.+r -Y _^ ...+ I HERS REQUIREDS'VERIFICATION' 44- Items in;this-sectionirequirOfield testing and/or verif catiorPby'atdertified HERS Rater. jThe'linspeciFmust receive a com leted`CF=4R foam for` eacli of tF 6 measures listed below for final to'be' giveii. The HVAC System HVAC 8 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. 1. V The HVAC System HVAC 9 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 9 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 9 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 9 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 9 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. • � rIAOp {SAFE /A I 1 r -UR CONSTRI ® r ATE " r I N EnemyPro 5.1 by EnemySoft User Number. 6712 Run Code: 201405-01T15:56:32�ID: Y Page 8o 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider'` S, Inc Electrpnically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at Ca10ERTS.com by Tammv Jenkins (Disrnvery nn;7Aara rad;fn n;.1 q/,/IMA PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 5/1/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin , TDV kgtu/ft2- r Space Heating 3.83 4.31 -0.48 Space Cooling 52.66 50.08 2.57 Fans 10.13 12.72 -2.59 Domestic Hot Water 2.48 1.67 0.81 Pumps 0.00 0.00 0.00 Totals 69.10 68.78 0.32 Percent Better Than Standard: 0.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext: Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 5,393 2,100 Fuel Available at Site: Natural Gas (S) 2,947 877 Raised Floor Area: 0 (Vtq 5,431 1,970 Slab on Grade Area: 11,943 (N) 2,697 1,466 Average Ceiling Height: 12.8 Roof 10,902 0 Fenestration Average U -Factor: 0.48 - TOTAL: 6,414 Average SHGC: 0.30 Fenestration/CFA Ratio: 43.7% REMARKS-- --. t,_ The Madison Club Country Club Lots 101 & 102 All STATEMENT.'OF COMPLIANCE This certificate of compliance'lists the building features and specifications needed' to comply with Title 24, Parts 1, the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 5/1/2014 • City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Giannetti Architecture & Interiors, Inc. F / �► Address 11-980 San Vicente BI Ste 101 Name Giannetti Architecture & Interiors A R4 � 2� �T� City/State/Zip L.A.; CA 90049 Phone (310) 820-1329 ' Sied( License_# SER%Date r .. NUC 'r/(-) l EnemvPro 5. 1 by EneMySoft User Number: 6712 Run Code: 2014-05-01 71 5:56:32 _""--ID: Page 91of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16_1HERS roProP vRte'r: Ca10ERTS, Ind a Electronically Filed by Tim Scott and Authenticated at CalCERTSV.com - 5/1/2014 Electronically Siqned at CalCERTS.com by Tammv Jenkin4 migenv w n„iIA- r=1if.,,4I ci,i�n,A CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project NameBuilding Lippman Res Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interiorl Frame Azm Tilt Status 4 Location/Comments Wall 115 0.069 R-21 0 90 New 4.3.1-A6 Maid Quarters Wall 324 0.069 R-21 90 90 New 4.3.1-A6 Maid Quarters Wall 320 0.069 R-21 180 90 New 4.3.1-A6 Maid Quarters Wall 305 0.069 R-21 270 90 New 4.3.1-A6 Maid Quarters Door 24 0.500 None 270 90 New 4.5.1-A4 Maid Quarters Slab 98 0.730 None 0 180 1 New 4.4.7-A1 Maid Quarters Slab 895 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Roof 154 0.026 R-38 270 0 New 4.2.1-A9 Kitchen & Dining Wall 211 0.069 R-21 90 90 New 4.3.1-A6 Kitchen & Dining Door 24 0.500 None 90 90 New 4.5.1-A4 Kitchen & Dining Wall 207 0.069 R-21 180 90 New 4.3.1-A6 Kitchen & Dining Wall 135 0.069 R-21 270 90 New 4.3.1-A6 Kitchen & Dining Slab 280 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Slab 1,175 0.730 None 0 180 New .4.4.7-A 1 Kitchen & Dining Roof 2,536 0.026 R-38 270 0 New 14.2.1-A9 ILiving Wall 2041 0.069 R-21 0 90 New 14.3.1-A6 ILiving FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 25.4 0.490 NFRC 0.26 NFRC 180 New Fixed -Dual Maid Quarters 2 . Window 40.0 0.290 COG 0.28 COG 180 New Swing Door Maid Quarters 3 Window • - 25.4 0.490 NFRC 0.26 NFRC 180 New Fixed -Dual Maid Quarters 4, Window 24.8 0.490 NFRC 0.26 NFRC 180 New Fixed -Dual Maid Quarters 5 '., 6 Window _ 91.8 0.290 COG.- Window;* I.: '273.2 0.450 NFRC dt ,0.28, COG, , _ 90 New Kitchen & Dining 0.24 NFRC TJ ` =270 New.;i'w'4 Panel,Dooisq(�,, F,.>it5f ,< 1a Kitchen & Dining 7 Wlndbwr 1 135.2 0.450 I.NFRC: -/ .: 0.24 'NFRC :; r " -0 NewfiA:r') Panel Doors%10-w .. ICIN , •. Living 8 Window 135.2-,!Z0.450, NFRC fk f- 0.24 NFRC1.' .At 0 New;, Panel Doors.41:,: Living -' - 9 Window 149f2 A0.350 COG ?4 0.42 CO,GJJ�11 11<•;90 New;,' 'V Fixed -Dual -Butt _ . LivingjZ;7- 10 Window AF 149.1•i,*,0.350; COGrA 0.42 COG,,, - A(90 `New -11W; Fixed -Dual -Butt, 4`-' -ex t LivingOtIAF AV 11 Window,+ I xf355.`7 X0:350 COGS? ii�e0.42 COG i dV,90 New -1- 4 Fixed -Dual -Butt #' ;' 3 Living 12 Window •eT 355.7 '0.450 NFRC- "•0.24 NFRC.. - -= 90 New Panel Doors' - Living 13 Window _ 149.1 0.350 COG 0.42 COG 180 New Fixed -Dual -Butt Living 14, . W7ndow ".•- 1-135.2 135.2 0.450 NFRC 0.24 NFRC 180 New Horizontal Slider Living 15 JWindow ' 392.1 0.480 1 NFRC 0.56 NFRC 270 New Pocket Door Living 16 lWindow 1 149.1. 0.450 1 NFRC 0.24 NFRC 0 New 1 Panel Doors Master (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Right Fin H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 10.0 33.0 30.0 0.1 30.0 30.0 7 Bug Screen 0.76 8 Bug Screen 0.76 , 9 Bug Screen 0.76 10 Bug Screen 0.76 Y i �• A -��- . 11 Bug Screen 0.76 b l f l n „• ; " ° r. `� - f ! (A .."'l 12 Bug Screen 0.76 10.01 18.0 6.0 0.1 6.0 13 Bug Screen 0.76 A t 01 !^-• , _ ` ` LlF1 �T 14 Bug Screen 0.76 Fr;n 15 Bug Screen 0.76 10.0 40.01 14.01 0.1 14!0 14.0 16 Bug Screen 0.76 f Ii1 N I arE BY* EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-05-01 Pae 10 of 15 Reg:.213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at CalCERTS.com by Tammv Jenkins (Diacnvery Rniidpra rat;fnr.,;mi ci11,3n-,d CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 134 0.069 R-21 90 90 New 4.3.1-A6 Living Wall 26 0.069 R-21 180 90 New 4.3.1-A6 Living Wall 532 0.069 R-21 270 90 New 4.3.1-A6 Living Slab 3,377 0.730 None 0 180 New 4.4.7-A1 living Roof 635 0.026 R-38 270 0 New 4.2.1-A9 Master Wall 1261 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 4561 0.069 R-21 90 90 New 4.3.1-A6 Master Wall 2161 0.069 R-21 270 90 New 4.3.1-A6 Master Slab 9441 0.730 None 0 180 New 4.4.7-A1 Master Slab 3461 0.730 None 0 180 New 4.4.7-A1 Master Roof 1,3401 0.026 R-38 270 0 New 4.2.1-A9 Guest 1 & 2 Wall 2461 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 90 90 New 4.3.1-A6 Guest 1 & 2 Wall 516 0.069 R-21 180 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 270 90 New 4.3.1-A6 Guest 1 & 2 Slab 890 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 66.6 0.450 NFRC 0.24 NFRC 0 New Panel Doors Master 18 Window 267.5 0.450 NFRC 0.24 NFRC 270 New Panel Doors Master 19 Window -- 192.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors Master 20 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Guest 1 & 2 21 , Window , X135.2 0.450 NFRC 0.2,4_ NFRC_ _ ___.. 0 New ,._,� Panel Doors ______ _ , _ Guest 1 & 2 22 Window's X294.8 0.450 NFRC 0.24 NFRC,F#;o New; f� � Panel -Doors fr- Yi X �_ � "Play Room Bowling 23 Windows 144.7 0.450 NFRC W . .0.24 'NFRCe.r. 0 Newl'I1,',Pane/ Doors F F --= :'4r t_ ; Play Room Bowling 24 Window 135.2 7` 0.450, NFRC F;� a 0.24 NFRC ;,.d 0 New, :w0"P, anel Doors 0, VA , Play Room Bowling 25 Window . 17,0'2 1,0.450 NFRC.'.y, 0.24 NFRC'.it . 9" 90 New., , Panel Doors},.- A; :V, Play, Room,Bowling 26 Window W 170.2, x,,0.450; NFRC•:s 0.24 NFRCr ,tt90'Newr! Panel Doors#4 Play Room Bowling 27 Window,A#; 4.170.`2 40.450 NFRC&,1 -.w6._24.NFRCxZv 90 New", ' P.anel'Doom.- � 'A P/ayRoom;Bowling 28 Window' 170.2 10.450 NFRC �_ 4' '.0.24 NFRC 90 New" Panel Doors'" Play Room Bowling 29 Window 56.8 0.290 COG 0.28 COG 180 New Pivot Door Play Room Bowling 30,.. Window • : " ,14.5 0.290 COG 0.28 COG 180 New Pivot Door Play Room Bowling 31 Window 128.3 0.450 NFRC 0.24 NFRC 180 New Horizontal Slider Play Room Bowling 32 Window 170.2 1, 0.450 NFRC 0.24 NFRC 270 New Horizontal Slider Play Room Bowling (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hang Left Fin Ri ht Fin Hat Wd Len Hat LExt RExt Dist Len Hat Dist Len Hat 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 25 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 r6;0- 6;026 26 Bug Screen 0.76 10.01 18.0 6.0 0.1 6.01 1 6.0� 27 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.."0° 1 28 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 /6;Q,,I ! A 29 Bug Screen 0.76 10.0 14.0 6.0 0.1 6.0 % 6.0 ``JirVt; "7 (•� ItA ��. 30 Bug Screen 0.76 If 4 � .-,. "" DAPI---, , `" ' .f I A I 31 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0,1 6.0: 1 -k4 32 IBua Screen 0.76 10.0 18.0 6.0 0.1 6.P 6.0 L' q,,Ll•'►�� r DATE v� �UcTioN EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201405-01T15:56J2`_ 0Page 11 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HER` P:o Dd 10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 5/1/2014 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 OPAQUE SURFACE DETAILS Surface -Type Area U- Insulation Joint Appendix I Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 450 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 Roof 2,656 0.026 R-38 270 0 New 4.2.1-A9 Play Room Bowling Wall 41 0.069 R-21 0 90 New 4.3.1-A6 Play Room Bowling Wall 923 0.069 R-21 90 90 New 4.3.1-A6 Play Room Bowling Wall 430 0.069 R-21 180 90 New 4.3.1-A6 Play Room Bowling Wall 1,720 0.069 R-21 270 90 New 4.3.1-A6 Play Room Bowling Slab 2,370 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Slab 286 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Roof 832 0.026 R-38 270 0 New 4.2.1-A9 Theater Wall 324 0.069 R-21 0 90 New 4.3.1-A6 Theater Wall 3241 0.069 R-21 90 90 New 4.3.1-A6 Theater Wall 3241 0.069 R-21 180 90 New 4.3.1-A6 Theater Slab 8321 0.730 None 0 180 New 4.4.7-A1 Theater Roof 2,749 0.026 R-38 270 0 New 4.2.1-A9 2nd Floor Wall 175 0.069 R-21 0 90 New 14.3.1-A6 2nd Floor Wall 512 0.069 R-21 1 901 90 1 New 14.3.1-A6 12nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Horizontal Slider 2nd Floor 34 Window 169.5 0.450 NFRC 0.24 NFRC 90 New Horizontal Slider 2nd Floor 35 Window 112.5 0.490 NFRC 0.26 NFRC 90 New Fixed -Dual 2nd Floor 36 Window 35.7 0.490 NFRC 0.26 NFRC 90 New Fixed -Dual 2nd Floor 37 Window_ 51.9 0.290 COG 0.28 COG 180 New _ _ Pivot Door - 2nd Floor 38 Window `6.4 0.480 NFRC J . 0.56 NFRC 180 New Pocket Door I f 2nd Floor 39 Window 191.1 0.480 NFRC 0.56 NFRC 180 New . Pocket Door 2nd Floor 40 Window 21.4; '_'0.290 COG 0.28 COG --(180 New '- Pivot Door 2nd Floor 41 Window 85:5 / 0.480 NFRC 0.56 NFRC 180 New Pocket Door 2nd Floor; 42 Window ,{ 121.4, , 0.290 COG 0.28 COG ;180 New Pivot Door 2nd Floor, 43 Wndow4 / 4209.0 0.450 NFRC --0.24 NFRC 270 New Panel Doors 2nd Floor ' 44 Window 60.6 0.490 NFRC 0.26 NFRC 270 New Fixed -Dual 2nd Floor 45 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor 46 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor 47 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Ri ht Fin Len H t LExt I RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 37 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 38 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 f-%, 43 Bug Screen 0.76 10.0 22.0 10.0 0.1 15. 0- `"'10.0, 44 Bug Screen 0.76 10.0 22.0 10.0 0.1 ,10.6- a10:0- 45 Bug Screen 0.76 6:0`°vU ', c� ._ 10.0 14.0 6.0 0.1 16.0kF(-r6b `"f :1I SIT., 46 Bu Screen 0.76 10.0 14.0 6.0 0.1 6.0.1 r-. . �` it ; /-w ,� 47 Bu Screen 0.76 10.0 14.0 6.0 0.1 �1�16. ��I�L�i�." L;4 N LATy � � LK r iolV F EnergyPro 5.1 by EnergySoft User Number., 6712 Run Code: 201405-01T1_6:56:32, ID:By i Pae 12 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Pro`a10ERTS, Inc Electrgnically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 ,Electronically Siqned at CalCERTS. com by Tammv Jenk; n4 I n; arnva" n,,; i'iora CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 5/1/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 246. 0.069 R-21 180 90 New 4.3.1-A6 2nd Floor Wall 145 0.069 R-21 270 90 New 4.3.1-A6 2nd Floor FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments k lr @�n ' Af F- � 4, 4, A±yfi &0'4" M'* :V <h aR s al.'r % (+p, ti a+" "� •rs •_ jl..' ^1t 4 2f y"�f Yi✓/i 'gieS:f ..:+ear 18� �lC� M •';�O" I , (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1(-o N ,1 EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 201405-01715:56:32 1D:----- Pae 13 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc ` �I Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 .Electronically Signed at CalCERTS.com by Tammv Jenkins .(Discovery Ruildera ralifnrnial s/i/901a CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Maid Quarters 993 11,420 HVAC 2 Kitchen & Dining 1,455 16,733 HVAC 3 & 4 Living 3,377 47,953 HVAC 5 Master 1,290 15,480 HVAC 6 Guest 1 & 2 1,340 16,080 HVAC 7 Play Room Bowling 2,656 37,184 HVAC 8 Theater 832 11,648 HVAC 9 2nd Floor 2,749 31,614 Totals 14,6921 0 0 0 HVAC SYSTEMS System Name Qty:!J Qty:!Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 j Split Heat Pump 10.00 HSP Split Heat Pump 18.0 SEER Setback New HVAC 2 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 3 & 4x 2 -Split . Heat;P,ump?'.,t: '9:50 HSPF S lit -Heat P,um 46. -0 -SEER, Settiack New HVAC 5A(? 1 S 7it'Heat Pum V 9.50 HSPF S IitjHeat Pum .?��,.cj ':16.0 SEER Setback,. New HVAC,rf't-f 1,t. Split Heat Pump 9:5�0,HSP. F Spl(jd H, eat, Pump a`" Via' 1j16.0 SEER Setback` � - New yy6 R �Js• .�'. 1A rR�" °t �1��1� Y.��Ir 1.'.. '�.. ,f"b �9�*'. �^{.{L�4 �F���/ � nwr �!yt. HVAC;DISTRIBUT•ION 1 -,&-.t tt '.^ Duct#W V. Ducts1"40 System Name' t eati� `-'Cooling'� s Duct Location `R -Value Tested? Status HVAC 1 _�� Ducted Ducted Conditioned 8.0 m New HVAC 2."' ? t Ducted Ducted Conditioned 8.0 IZI New HVAC 3 & 4 Ducted Ducted Conditioned 8.0 El New HVAC 5 Ducted Ducted Conditioned 8.0 m New HVAC 6 Ducted Ducted Conditioned 8.0 m New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh .Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. 'Tank Insul. R- Value Status Bradford -White Corp. M-1- 3 Large Gas All Pipes Ins 85,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff c o Q cjF ° OF B�S.s'tem(Namii- _ _ �- ped 1 -Un-`th�l 'Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried Y� ❑ 1 .40. A��:..,. �x `Sf`'it' i _ 1Y i� F'a '' ❑I ° ��" �`'w 9� 1 ❑i'` R CO �rc�� 0 °.. M JUN 11 MATP EnergyPro 5.1 6 y EneroySoft User Number. 6712 RunCode: 2014-05.01T15:56:32 -SID -i..r _ �— Pae 14 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc e Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 5/1/2014 ,Electronically Signed.at CalCERTS.com by Tammy Jenkins (Discovery Builders califnrnia) s/i/�nia CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type 10 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existing Altered Removed Volume Year Built Totals 14,6921 0 01 0 HVAC SYSTEMS System Name Oty."I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status_ HVAC 7 - 1 $ Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 8 1 Split Heat Pump 10.00 HSP Split Heat Pump 18.0 SEER Setback New HVAC 9 2 , _S ww,1yn16.0-SEER, Setback New Heat Puinprjr.*-'9.50-HSIP-F Split:Heat"P,.u�im (yam y Jllit RSA '�f,/{� � 11• 1� i--A'�r �•y',{Jyi�''�rryy..�M'.�1� +�lA+ ` �.",YR �•-�r �4, /-� .J�' •t-- Jae F - r l.'. t. ll ^=i.A iC:'T i F�yy�,4� --a..• - ��'��'+��pX( �ytly.{�>^��y?.;..r' }yc+. S' 7r , I .+ R '.}'A'-1... , I—.. ti't i1ti1.>i1...�Yr• _ �Y..� w h HVAC DISTRIBUTION ' ;' ;H1011`0' `. �✓ ** sa�Ys.z• i> resr�d,sn �' Ductf W 0 Ductsf~''I - �. ' 'W'o S stem Name ' € I Heatin T �Coolin Duct Location R -Value Tested? Status HVAC 7 _�,., Ducted Ducted Conditioned 8.0 m New HVAC 8> " Ducted Ducted Conditioned 8.0 m New HVAC 9 Ducted Ducted Conditioned 8.0 D New WATER HEATING SYSTEMS S stem Name Ot . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby ; Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft c 0 N a f�ee1T System Pipe „ Length, qP'~--ip-e � iameter� 'Insul. Thick. 7QtyHP Plenum Outside Buried ❑ I —.. �77r li C1 0At-L:11 D PT M FOR y` I 13 ❑ i �—BY- EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01 T15:56:32 f Pae 15 of 15 Reg: 213-N0035232E-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc I BUILDING ENERGY ANALYSIS REPORT PROJECT: Lippman Res Lot 101 & 102 Baffin Ave. La Quinta, CA 92253 Project Designer: Giannetti Architecture & Interiors, Inc. 11-980 San Vicente BI Ste 101 L.A., CA 90049 (310) 820-1329 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: uI OF I� 'NG & QIJI �a4 5/1/2014 F� jY NTA The EnergyPro computer program has been used to perform the calculations summarized, in -this l�o ce repLThisgrarn has approval and is authorized by the California Energy Commission for use with both the Residential4and Nonresid� ti 1 Qf08 Buy Efficiency Standards. BThis program developed by EnergySoft, LLC — www.energ soy ft-com. EnergyPro 5.1 by EnergySoR User Number., 6712 RunCode: 201405-01715:56:32 ID: 'r • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status Wall Wood Framed R-21 10,006 New Door Opaque Door None 48 New Slab Unheated Slab -on -Grade None 11,943 Perim = 978' New Roof Wood Framed Attic R-38 10,902 Radiant Barrier New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Left (S) 75.6 0.490 0.26 none none Bug Screen New Left (S) 40.0 0.290 0.28 none none Bug Screen New Front (E) 91.8 0.290 0.28 none none Bug Screen New Rear (Kq 273.2 0.450 0.24 30.0 none Bug Screen New Right (N) 1,196.0 0.450 0.24 none none Bug Screen New Front (E) 654.0 0.350 0.42 none none Bug Screen New Front (E) 1,036.5 0.450 0.24 6.0 none Bug Screen New Left (S) 149.1 0.350 0.42 none none Bug Screen New Left (S) 135.2 0.450 0.24 none none Bug Screen New Rear (Kq 392.1 0.480 0.56 14.0 none Bug Screen New Rear (lAq 459.7 0.450 0.24 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 1 Ducted Ducted Conditioned 8.0 New HVAC 2 Ducted Ducted Condditioned -1-V r 8.0 New HVAC 3&4 Ducted Ducted Conditionedlnt�r„d��8.0�11`� New WATER HEATING `" LX �JAFETy DEP-r.' T.� Qt Type Gallons Min. Eff Dist�r.'ibu#ion (1�,�'�>r-1,, Status R�� 3 Large Gas 100 _ 0.80 All Pipes Ins I �UC �1 �r New Y� UA TP V 1 By EnetgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01T15:56:32 ID: Page 3 of 54 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST El Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity f Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 135.2 0.450 0.24 6.0 none Bug Screen New Left (S) 130.1 0.290 0.28 6.0 none Bug Screen New Left (S) 35.9 0.290 0.28 none none Bug Screen New Left (S) 128.3 0.450 0.24 6.0 none Bug Screen New Rear (W 170.2 0.450 0.24 6.0 none Bug Screen New Right (N) 135.2 0.450 0.24 none none Bug Screen New Front (E) 169.5 0.450 0.24 none none Bug Screen New Front (E) 112.5 0.490 0.26 none none Bug Screen New Front (E) 35.7 0.490 0.26 6.0 none Bug Screen New Left (S) 6.4 0.480 0.56 6.0 none Bug Screen New Left (S) 176.6 0.480 0.56 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Conditioned4 y�-� , 8.0 New HVAC6 Ducted Ducted Condition diR� ,0�8.'Qjf�-� New HVAC 7 Ducted Ducted Conditioned "Mt"'\""' J SAFF-+BNOtir- r, N New WATER HEATING�`'i,f-•"`O Qt Type Gallons Min. Eff Distribution'�S7'��E"D , Status •rr"Y EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2014-05-01715:56:32 /D: Page 4 of 54 • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,692 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (IM 209.0 0.450 0.24 10.0 none Bug Screen New Rear (149 60.6 0.490 0.26 10.0 none Bug Screen New Rear (tM 405.6 0.450 0.24 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 8 Ducted Ducted Conditloned-----, 8.0 New HVAC 9 Ducted Ducted ConditioneT n C 8; O^ New BUiLUlNG A��A N WATER HEATING `". '" " r i- L:PT. Ot . Type Gallons Min. Eff Dist it butipm."..— Status �.� „uk- r ION N DATE EnergyPro 5. 1 by EnergySoft User Number: 6712 Run Code: 2014-05-O1T15:56:32 /D: Page 5 of 54 171 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 1 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'ustification and documentation submitted. The DHW System Bradford -White Corp. M-1-100TON is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC 1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Covered Slab Floor, 3.500" thick at Maid Quarters HIGH MASS Design - Verify Thermal Mass: 895.0 ft2 Exposed Slab Floor, 3.500" thick at Maid Quarters The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 280.0 ft2 Covered Slab Floor, 3.500" thick at Kitchen & Dining HIGH MASS Design - Verify Thermal Mass: 1,175.0 ft2 Exposed Slab Floor, 3.500" thick at Kitchen & Dining The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan waft draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 3,377.0 ft2 Exposed Slab Floor, 3.500" thick at Living The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 944.0 ft2 Covered Slab Floor, 3.500" thick at Master HIGH MASS Design - Verify Thermal Mass: 346.0 ft2 Exposed Slab Floor, 3.500" thick at Master The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 25HNB924/FE4ANB003 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 1 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser.=A=certified _HERS rater must field verify the installation of the correct Condenser. I G.' 1—Y � r � n ;Z . The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm.'1 r �.�� 0;tFETY nc - The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge ora Charge Indicator Disp/a):! -- Compliance credit for quality installation of insulation has been used. HERS fieldwerification is re40itdO0 1 t-1UU -f/ON The HVAC System HVAC 2 has Ducts, Plenums and the HVAC unit located totally``within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 201405-01 T15:56:32 ID: Page 6 of 54 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 890.0 ft2 Covered Slab Floor, 3.500" thick at Guest 1 & 2 HIGH MASS Design - Verify Thermal Mass: 450.0 ft' Exposed Slab Floor, 3.500" thick at Guest 1 & 2 The HVAC System HVAC 7 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,370.0 ft2 Covered Slab Floor, 3.500" thick at Play Room Bowling HIGH MASS Design - Verify Thermal Mass: 286.0 ft2 Exposed Slab Floor, 3.500" thick at Play Room Bowling The HVAC System HVAC 8 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 832.0 ft2 Covered Slab Floor, 3.500" thick at Theater The Roof R-38 Roof Foam includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4ANS006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 3 & 4 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 3 & 4 includes credit for verified adequate airflow. A certified HERS"rater-must_diagnostically measure airflow of the HVAC System. 1 Cry (+r_- I The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification.and'diagnostic'tesiin'g" is' [equired,to verify that duct leakage meets the specified criteria. 1 � E Spy F� k l 4 J )l The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenses: )A certified'HERS,rate? must'field"verify'the installation of the correct Condenser.�fi f7 `� The HVAC System HVAC 5 includes credit for Verified Fan Energy. Measured Fan Energy may ridt exceed 0:58, w,/�gfm 7-10N The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. aY EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 201405-01 T15:56:32 ID: Page 7 of 54 • CJ PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require.field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 5 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HN8960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 6 has Ducts, Plenums and the HVAC unit located totally within.Conditioned'sp_a_'ce. A certified BHEiRS^i�a-ter must visually verify the installation of the HVAC unit and all Ducts and Plenums. p t ILIA `� U 11� 1 A I The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS raterhibsi`dlagnostkallj'iAea's5 airflow of the HVAC System. �. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS fieldi'verification•and diagribstic°testirigL'is,required to verify that duct leakage meets the specified criteria. r Vrl UUNSTRJCTION The Cooling System Carrier 25HN8960/FE4AN8006 includes credit for a 12.5 EER g Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ! DATE EnemyPro 5.1 by EnemZSoft User Number: 6712 RunCode: 201405-01T15:56:32 ID: Page 8 of 54 0 • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project NameBuilding Lippman Res Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 7 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 7 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9241FE4ANB003 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 8 includes credit for Verified Fan Energy. Measured Fin—Energy-may not exceed 0.58 w/cfm. I cI7`V ter+ . The HVAC System HVAC 8 incorporates HERS Verified Refrigerant Charge oraChha�eInddi ator'Display.4A QUI TA—] Compliance credit for quality installation of insulation has been used. HERS field verification,@''requi' d+. `' ' r ut pT. I Y W r, , a 0I/P �.�� . The HVAC System HVAC 8 has Ducts, Plenums and the HVAC unit located totally within-Cdnditiorieb sp`ace� A•certifiedHERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. v �' f ION 1 The HVAC System HVAC 8 includes credit for verified adequate airflow. A certifledrHERS rater must diagnostically measure ai ow of the HVAC System. �� 8Y EnemvPro 5.1 by EnerqySoft User Number. 6712 Run Code: 201405-01T15:56:32 ID: Page 9 of 54 C • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑.Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 8 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 9 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 9 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. Compliance credit for quality installation of insulation has been used. HERS field verification is required. The HVAC System HVAC 9 has Ducts, Plenums and the HVAC unit located totally within Conditioned space. A certified HERS rater must visually verify the installation of the HVAC unit and all Ducts and Plenums. The HVAC System HVAC 9 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 9 incorporates HERS verified Duct Leakage. HERS field ° verification�and diagnostic testing is required to verify that duct leakage meets the specified criteria. r 87-V r -N P. - I APPROM'pn�rt- 1 ' "'l w STRUCTION DATE BY— EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 201405-01 T15:56:32 ID: Pae 10 of 54 • C� J PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type. m Single Family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 1 5/1/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ftZ- r Space Heating 3.83 4.31 -0.48 Space Cooling 52.66 50.08 2.57 Fans 10.13 12.72 -2.59 Domestic Hot Water 2.48 1.67 0.81 Pumps 0.00 0.00 0.00 Totals 69.10 68.78 0.32 Percent Better Than Standard: 0.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 5,393 2,100 Fuel Available at Site: Natural Gas (S) 2,947 877 Raised Floor Area: 0 (vv) 5,431 1,970 Slab on Grade Area: 11,943 (N) 2,697 1,466 Average Ceiling Height: 12.8 Roof 10,902 0 Fenestration Average U -Factor: 0.48 TOTAL: 6,414 Average SHGC: 0.30 Fenestration/CFA Ratio: 43.7% REMARKS The Madison Club Country Club Lots 101 & 102 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scoff Design and Title 24, Inc, Address 77-085 Michigan Drive Name Tim Scott 5/12014 City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the p or posed=building design represented in this set of construction documents is consistent with the other compliance .forms(arid-o`rksh: e- s with-the.specifications, and with any other calculations submitted with this permit application, and recogTzes�trh�atc olmptianceuu,N iin,�g�ductmdesign, duct sealing, verification of refrigerant charge, insulation installation quality, and buildmg7envelope sealinglt uire installer testing and certification and field verification by an approved HERS,�ater P ` Y OEpT. Fpi3 Designer or Owner (per Business & Professions Code) CONSOVED Company Giannetti Architecture & Interiors, Inc, ;ON DgTE Address 11-980 San Vicente B/ Ste 101 Name Giannetti Architecture &-Interiors City/State/Zip L.A., CA 90049 Phone (310) 820-1329 Signed �L'icense_# Date EnemyPro 5.1 by EnemySoft User Number. 6712 Run Code: 2014-05-01715:56:32 /D: Pae 11 of 54 • s CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 115 0.069 R-21 0 90 New 4.3.1-A6 Maid Quarters Wall 324 0.069 R-21 90 90 New 4.3.1-A6 Maid Quarters Wall 320 0.069 R-21 180 90 New 4.3.1-A6 Maid Quarters Wall 305 0.069 R-21 270 90 New 4.3.1-A6 Maid Quarters Door 241 0.500 None 1 270 90 New 4.5.1-A4 Maid Quarters Slab 98 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Slab 895 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Roof 154 0.026 R-38 270 0 New 4.2.1-A9 Kitchen & Dining Wall 211 0.069 R-21 90 90 New 4.3.1-A6 Kitchen & Dining Door 24 0.500 None 90 90 New 4.5.1-A4 Kitchen & Dining Wall 207 0.069 R-21 180 90 New 4.3.1-A6 Kitchen & Dining Wall 135 0.069 R-21 270 90 New 4.3.1-A6 Kitchen & Dining Slab 280 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Slab 1,175 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Roof 2,536 0.026 1 R-38 270 0 New 14.2.1-A9 JLiving Wall 1 2041 0.069 R-21 0 90 New 14.3.1-A6 ILiving FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 25.4 0.490 NFRC 0.26 1 NFRC 180 New Fixed -Dual Maid Quarters 2 Window 40.0 0.290 COG 0.28 1 COG 180 New Swing Door Maid Quarters 3 Window 25.4 0.490 NFRC 0.26 NFRC 180 New Fixed -Dual Maid Quarters 4 Window 24.8 0.490 NFRC 0.26 NFRC 180 New Fixed -Dual Maid Quarters 5 Window 91.8 0.290 COG 0.28 COG 90 New Swing Door Kitchen & Dining 6 Window 273.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors Kitchen & Dining 7 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Living 8 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Living 9 Window 149.2 0.350 COG 0.42 COG 90 New Fixed -Dual -Butt Living 10 Window 149.1 0.350 COG 0.42 COG 90 New Fixed -Dual -Butt Living 11 Window 355.7 0.350 COG 0.42 COG 90 New Fixed -Dual -Butt Living 12 Window 355.7 0.450 NFRC 0.24 NFRC 90 New Panel Doors Living 13 Window 149.1 0.350 COG 0.42 COG 180 New Fixed -Dual -Butt Living 14 Window 135.2 0.450 NFRC 0.24 NFRC 180 New Horizontal Slider Living 15 Window 392.11 0.480 1 NFRC 0.56 NFRC 270 New Pocket Door Living 16 Window 149.11 0.450 1 NFRC 0.24 NFRC 0 New Panel Doors Master (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SH GC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist I Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 10.0 33.0 30.0 0.1 30.0 30.0 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bua Screen 0.76 10 Bug Screen 0.76 1 "L -u'1 I; 11 Bug Screen 0.76 12 Bug Screen 0.76 10.0 18.0 6.0 0.1 16.0 C6.0., 13 Bug Screen 0.76 i GO I C--; '- 14 Bug Screen 0.76 --& 15 Bug Screen 76 10.0 40.0 14.0 0.1 114?.0 Tc 14.0 1 ]Bug Screen 0.76 EnergryPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-05-01T15:56:32 ID: Pae 12 of 54 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF=1 R Project NameBuilding Lippman Res 7 Type m Single Family ❑ Addition Alone El Multi Family ❑ Existing+ Addition/Alteration Date x;1V2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor CavityExterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wall 134 0.069 R-21 90 90 New 4.3.1-A6 Living Wall 26 0.069 R-21 180 90 New 4.3.1-A6 Living Wall 532 0.069 R-21 270 90 New 4.3.1-A6 Living Slab 3,377 0.730 None 0 180 New 4.4.7-A1 Living Roof 6351 0.026 R-38 270 0 New 4.2.1-A9 Master Wall 1261 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 456 0.069 R-21 90 90 New 4.3.1-A6 Master Wall 216 0.069 R-21 270 90 New 4.3.1-A6 Master Slab 944 0.730 None 0 180 New 4.4.7-A1 Master Slab 346 0.730 None 0 180 New 4.4.7-A1 Master Roof 1,340 0.026 R-38 270 0 New 4.2.1-A9 Guest 1 & 2 Wall 246 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 90 90 New 4.3.1-A6 Guest 1 & 2 Wall 516 0.069 R-21 180 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 270 90 New 4.3.1-A6 Guest 1 & 2 Slab 890 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Wndow 66.6 0.450 NFRC 0.24 NFRC 0 New Panel Doors Master 18 Window 267.5 0.450 NFRC 0.24 NFRC 270 New Panel Doors Master 19 Window 192.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors Master 20 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Guest 1 & 2 21 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Guest 1 & 2 22 Window 294.8 0.450 NFRC 0.24 NFRC 0 New Panel Doors Play Room Bowling 23 Window 144.7 0.450 NFRC 0.24 NFRC 0 New Panel Doors Play Room Bowling 24 Window 135.2 0.450 NFRC 0.24 NFRC 0 New Panel Doors Play Room Bowling 25 Window 170.2 0.450 NFRC 0.24 NFRC 90 New Panel Doors Play Room Bowling 26 Window 170.2 0.450 NFRC 0.24 NFRC 90 New Panel Doors Play Room Bowling 27 Window 170.2 0.450 NFRC 0.24 NFRC 90 New Panel Doors Play Room Bowling 28 Window 170.2 0.450 NFRC 0.24 NFRC 90 New Panel Doors Play Room Bowling 29 Window 56.8 0.290 COG 0.28 COG 180 New Pivot Door Play Room Bowling 30 Window 14.5 0.290 COG 0.28 COG 180 New Pivot Door Play Room Bowling 31 JWndow 128.3 0.450 NFRC 0.24 NFRC 180 New Horizontal Slider Play Room Bowling 32 lWindow 1 170.2 0.450 NFRC 0.24 NFRC 270 New Horizontal Slider Play Room Bowling (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SH Window H t Wd Ove hanq Len H t I LExt RExt Left Fin Right Fin Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 10.01 18.0 6.0 0.1 r6.0 25 Bug Screen 0.76 10.01 18.0 6.0 0.1 16.0 >r e,,6.6, '' ° LAA (-)1 #6' 26 Bug Screen 0.76 10.0 18.0 6.0 0.1 J6.0 -"60 ►Vivi c Q,r,,- iV I J I 27 Bug Screen 0.76 10.0 18.0 6.0 0.1 16.0 ,6.0 28 Bug Screen 0.76 10.0 18.0 6.0 0.1 1 6.0 r-. 6.0. 29 Bug Screen 0.76 10.0 14.0 6.0 0.1 N 6.0 30 Bug Screen 0.76 t ill N 31 IBug Screen 0.761 10.0 18.0 6.0 0.1 ( C6 Qr - 6.0 32 JBug Screen 1 0.761 10.01 18.0 6.0 0.1 1--6.0 -6-0- EnefgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01T15:56:32 /D: Pae 13 of 54 • L� CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix I Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 450 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 Roof 2,656 0.026 R-38 270 0 New 4.2.1-A9 Play Room Bowling Wall 41 0.069 R-21 0 90 New 4.3.1-A6 Play Room Bowling Wall 923 0.069 R-21 90 90 New 4.3.1-A6 Play Room Bowling Wall 430 0.069 R-21 180 90 New 4.3.1-A6 Play Room Bowling Wall 1,720 0.069 R-21 270 90 New 4.3.1-A6 Play Room Bowling Slab 2,370 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Slab 286 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Roof 832 0.026 R-38 270 0 New 4.2.1-A9 Theater Wall 3241 0.069 R-21 01 90 New 4.3.1-A6 Theater Wall 324 0.069 R-21 901 90 New 4.3.1-A6 Theater Wall 324 0.069 R-21 180 90 New 4.3.1-A6 Theater Slab 832 0.730 None 0 180 New 4.4.7-A1 Theater Roof 2,749 0.026 R-38 270 0 New 4.2.1-A9 2nd Floor Wall 175 0.069 R-21 0 90 New .4.3. 1-A6 12nd Floor Wall 1 5121 0.069 R-21 90 90 1 New 14.3.1-A6 12nd Floor FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm Status Glazing Type Location/Comments 33 Window 135.2 0.450 1 NFRC 0.24 NFRC 0 New Horizontal Slider 2nd Floor 34 Window 169.5 0.450 NFRC 0.24 NFRC 90 New Horizontal Slider 2nd Floor 35 Window 112.5 0.490 NFRC 0.26 NFRC 90 New Fixed -Dual 2nd Floor 36 Window 35.7 0.490 NFRC 0.26 NFRC 90 New Fixed -Dual 2nd Floor 37 Window 1 51.9 0.290 COG 0.28 COG 1 180 New Pivot Door 2nd Floor 38 Window 6.4 0.480 NFRC 0.56 NFRC 180 New 1 Pocket Door 2nd Floor 39 Window 91.1 0.480 NFRC 0.56 NFRC 180 New Pocket Door 2nd Floor 40 Window 21.4 0.290 COG 0.28 COG 180 New Pivot Door 2nd Floor 41 Window 85.5 0.480 NFRC 0.56 NFRC 180 New Pocket Door 2nd Floor 42 Window 21.4 0.290 COG 0.28 COG 180 New Pivot Door 2nd Floor 43 Window 209.0 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor 44 Window 60.6 0.490 NFRC 0.26 NFRC 270 New Fixed -Dual 2nd Floor 45 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor 46 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor 47 Window 135.2 0.450 NFRC 0.24 NFRC 270 New Panel Doors 2nd Floor (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t I LExt RExt Dist Len H t Dist Len H t 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 37 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 38 Bug Screen 0.76 10.0 18.0 6.0 0.1 i"6:0 6.0 39 Bug Screen 0.76 1 1--R 40 Bug Screen 0.76 ` ' (J 1- ' A 7:7- 7-41 41 Bu Screen 0.76 1 �� ILDW "-T U,1, ("A 1 42 Bug Screen 0.76 10.0 18.0 6.0 0.1 1 6.0 - 6.0 `` 'HI'E''y r"ir if" 43 Bug Screen 0.76 10.0 22.0 10.0 0.1 f 10.0 - 44 Bug Screen 0.76 10.0 22.0 10.01 0.11 10.0E -C )r10 0` -r, . , : '- V i :: N 45 Bug Screen 0.76 10.0 14.0 6.0 0. 1,J 6.0 6.0 " "`y 1 t-1 U 46 Bug Screen 0.761 10.01 14.0 6.0 0.1 - ' 6.0 6.0 N 47 IBug Screen 0.761 10.01 14.0 6.0 O.j,1 "" °6:0 6.0 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201405-01 T15:56:32 ID: Pae 14 of 54 r� r 1 • I Project Name Lippman Res Building Type 0 Single Family ■ Addition . - 0 Multi Family 0 Existing+ Addition/Alteration •• • DETAILS - ndix Insulation JointAppe4 Location/Comments FEN WORM... .- •. EXTERI•- SHADING DETAILS Exterior Shade Type .-MU ILA CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 5/1/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina Altered Removed Volume Year Built HVAC 1 Maid Quarters 993 11,420 HVAC 2 Kitchen & Dining 1,455 16,733 HVAC 3 & 4 Living 3,377 47,953 HVAC 5 Master 1,290 15,480 HVAC 6 Guest 1 & 2 1,340 16,080 HVAC 7 Play Room Bowling 2656 37,184 HVAC 8 Theater 832 11,648 HVAC 9 2nd Floor Z 749 31,614 Totals 1 14,6921 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Split Heat Pump 10.00 HSPM Split Heat Pump 18.0 SEER Setback New HVAC 2 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 3 & 4 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 5 1 Split Heat Pump 9.50 HSPF SplitHeatPump 16.0 SEER Setback New HVAC 6 1 1 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVAC 1 Ducted Ducted Conditioned 8.0 m New HVAC 2 Ducted Ducted Conditioned 8.0 m New HVAC 3 & 4 Ducted Ducted Conditioned 8.0 El New HVAC 5 1 Ducted 1 Ducted I Conditioned 8.01 New HVAC 6 1 Ducted Ducted Conditioned 8.01 New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -White Corp. M-1- 3 Large Gas All Pipes Ins 85,000 100 0.80 0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ff C; � a "-- ClyLA j� gUiLDt' ®� P.)INv NG $� P' S'stemrName AF -7Len h°7j:)'Dianjeter T -,A i e Insul. Thick. Qt . HP Plenum Outside Buried o �-r-a' le, o v PLATE — o, EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01 T15:56:32 ID: Pae 16 of 54 • CJ CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type la Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1 5/1/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinci Altered Removed Volume Year Built Totals 14,692 0 0 0 HVAC SYSTEMS System Name Q!y. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 7 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 8 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HVAC 9 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Coolin Duct Location R -Value Tested? Status HVAC 7 Ducted Ducted Conditioned 8.0 m New HVAC 8 Ducted Ducted Conditioned 8.0 m New HVAC 9 Ducted Ducted Conditioned 8.0 0 New El WATER HEATING SYSTEMS Sstem Name Qt . Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC;IFIE:ATr,ING-S,YSTEM'PIPING_ Control Hot Water Piping Lengtho N a BUfLD�N�'� �DEPT P j=�R Isystern NameCONSLeFrt' '�-� ► l,, 1SAFE Pipe[ " vT�s h Pipe Niarpeter ainsul. JThick. Qt . HP Plenum Outside Buried ❑ UATE 1 0 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201405-01 T15:56:32 /D: Pae 17 of 54 4 4 t MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name ippman Res Date 5/1/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 4 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 150(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. 150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled and installed according to ASTM El677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is keguipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. -§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150"13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and pipingffjs'tira a heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150 A. d §150(j)2: Pipe insulation for steam hydronic heating systems or hot water syste`m's >$ isJ feet r jhe dards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moistu e e 'tt? i e a —d w' d. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines Includes EHS—p(Cr GtIrWo ed entir ly in conditioned space. t 150(j)4: Solar water -heating systems and/or collectors are certified by the %Edr Rating and Certification Cor ration. '_ By EnergyPro 5.1 by EnergySolf User Number: 6712 Run Code: 201405-01 T15:56:32 /D: Page 18 of 54 4 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date ippman Res 5/1/2014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene prog`rammable_control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, andjutillty%rooms=arehigh-effieaay and controlled by a manual -on occupant sensor. M L, , , . 'J►_iA n1 §150(k)9: Permanently installed lighting that is internal to cabinets shall'use no "more•than 20 watts- of-powerper-Iinea"r foot of illuminated cabinet. Fon C aTRtJC1`1 Law EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 2014-05-01T15.56.12'-- -- /D.;--_:7���",I Page 19 of 54 r MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ippman Res 1 5/1/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they.are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. OF: ILA gUi�orry Gl�il�-� & SAI-E7Y DEPT; � FO CO ��VED NSTRjjCT10,� oArE - BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01715:56:32 ID: Page 20 o/ 54 C 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 5/1/2014 System Name HVAC 1 Floor Area 993 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 322 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 25,400 7,492 1,469 661 12,873 Total Output Btuh 25,400 0 Output Btuh/s ft 25.6 108 146 Cooling System 0 0 Output perSystem 24,800 0 0 0 0 Total Output Btuh 24,800 0 108 7,709 1,469 0 Total Output Tons 2.1 146 Total Output Btuh/s ft 25.0 Total Output s ft/Ton 480.5 13,166 Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 25HNB924/FE4ANB003 18,808 647 15,864 Airflow cfm/s ft 0.81 Total Adjusted System Output 18,808 647 15,864 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3P MJan 1 AM Airflow cfm/Ton 387.1 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 90 OF 90 OF fns Heating Coil Supply Fan 90 OF 800 cfm ROOM 72 OF I . COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 57 °F 70/57°F 48/47°F 48/47°F QUINT Cooling Coil Supply800cfm n d+a & SAFE ` It 48 / 47 OF �'�P j. FOR COX44 5 IS ROOM �UCr/ON 70 157 OF By EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 2014-05-01T15:56:32 /D: ' "" Page 21 of 54 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ippman Res Date 5/1/2014 System Name AC 2 Floor Area 1,455 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 813 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,500 14,106 2,060 940 16,987 Total Output Btuh 58,500 0 Output Btuh/s ft 40.2 204 193 Cooling System 0 0 Output per System 55,500 0 0 0 0 Total Output Btuh 55,500 0 2,060 0 Total Output Tons 4.6 204 193 Total Output Btuh/s ft 38.1 Total Output s ftfron 314.6 1 14,514 17,373 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,103 10,162 36,538 Airflow cfm/s ft 1.37 Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 35,103 10,162 36,538 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 7PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF Heating Coil Supply Fan ° 2,000 cfm 89 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside AirB(J Ar 0 cfm 70/60°F 70 / 60 OF 54 / 53 OF 154../_53 OF CIT j( I .._ ' LJM 54 / 53 OF Cooling Coil Supply Fan ��®j dEP _r7 2,000 cfm — FOR CONSTF7 ?16 Ip I,r R00M no bA 70/59°F EnergyPro5.1 by EnergySoR User Number: 6712 Run Code: 2014-05-01T15:56:32 /D: Page 22 of 54 4 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ippman Res Date 5/1/2014 System Name AC 3 & 4 Floor Area 3,377 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 4,840 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,500 81,963 4,516 3,668 65,641 Total Output Btuh 117,000 0 Output Btuh/s ft 34.6 1,186 745 Cooling System 0 0 Output per System 55,500 0 0 0 0 Total Output Btuh 111,000 0 4,516 0 Total Output Tons 9.3 1,186 745 Total Output Btuh/s ft 32.9 Total Output s ft/Ton 365.1 1 84,335 67,131 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 25HNB960/FE4ANB006 70,113 20,706 73,075 Airflow cfm/s ft 1.18 73,075 I Jan 1 AM Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 70,113 20,706 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF Heating Coil Supply Fan 4,000 cfm 89 ° F ROOM 72 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 60 OF 70/60°F 54/53°F 54/53°F c O Fgvlj, 'a.aC _ . �, t e � `J ] (�e �1 q Cooling Coil Supply Fan f�C7 $� AFE� �'1 54 / 53 °F 4,000 cfm EPf;-- FOR ®4�8>oi ROOM STf�� jC� Idf 70 / 60 °F ' oAri= I EnergYPro5.1 by EnergySoff User Number: 6712 Run Code: 201405-01T15:56:32 /D: Page 23 of 54 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ippman Res Date 5/1/2014 System Name HVAC 5 Floor Area 1,290 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,416 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,500 24,480 1,849 1,374 24,717 Total Output Btuh 58,500 0 Output Btuh/s ft 45.3 354 281 Cooling System 0 0 Output perSystem 55,500 0 0 0 0 Total Output Btuh 55,500 0 1,849 0 Total Output Tons 4.6 354 281 Total Output Btuh/s ft 43.0 Total Output s ft/Ton 278.9 1 25,189 25,278 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,296 9,947 36,538 Airflow cfm/s ft 1.55 36,538 Jan 1 AM Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 35,296 9,947 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air(cfm /s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF f Cd•r� i Heating Coil Supply Fan a 2,000 cfm 89 F ROOM 72 OF I COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside AirAr 0 cfm 70 / 59 OF 70 / 60 OF 54 / 53 OF 54-/-53-?F. bUjJ : )fh ►n /q Supply Fan DEP 54 / 53 OF Cooling Coil PC OVE �. 2,000 cfm - - CONST5a.ZTJ ,p0M DATE I 70 / 59 OF EnergyPro 5.1 by EnergySoff User Number: 6712 Run Code: 201405-01715:56:32 /D: Page 24 of 54 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Lippman Res 5/1/2014 System Name Floor Area HVAC 6 1,340 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK I COIL HTG. PEAK Heating System CFM Sensible Latent I CFM Sensible Output perSystem 58,500 Total Room Loads 755 13,152 1,913 1,108 19,996 Total Output Btuh 58,500 Return Vented Lighting 0 Output Btuh/s ft 43.7 Return Air Ducts 190 227 Cooling System Return Fan 01 0 Output perSystem 55,500 Ventilation 0 0 0 0 0 Total Output Btuh 55,500 Supply Fan 0 0 Total Output Tons 4.6 Supply Air Ducts 190 227 Total Output Btuh/s ft 41.4 Total Output s ft/Ton 289.7 TOTAL SYSTEM LOAD I 13,533 1,913 1 20,450 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,208 10,015 36,538 Airflow cfm/s ft 1.49 Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 35,208 10,015 36,538 Outside Air cfm/s ft 0.00 (Adjusted for Peak Design conditions) Note: values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 72 OF 89 OF 89 OF f Cil � Outside Air 0 cfm Heating Coil Supply Fan 2,000 cfm 89 ° F ROOM 72 OF 72 OF 1 COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Coolino Peakl 112/78°F 70/60°F 54/53°F f -, —. ,e P f �(3 xx t�!►w� 1A_1 Outside Air c !pply an A , ,� QEP7- 0 cfmAL Cooling Coil 2U000 fm F R !� 54 / 53 °F �� CONST 54.oX. RO M d 70 / 59 °FV DATE _ �_ f 70 / 59 OF BY EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2014-05-01T15:56:32 ID: Paqe 25 of 54 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name ippman Res System Name HVAC 7 Date 5/1/2014 Floor Area 2,656 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 3,248 52,934 Return Vented Lighting 0 Return Air Ducts 766 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 766 TOTAL SYSTEM LOAD 54,4 66 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 58,500 3,594 3,731 65,384 Total Output (Il 58,500 Output Btuh/s ft 22.0 742 Cooling System 0 Output per System 55,500 0 0 0 Total Output (Il 55,500 3,594 0 Total Output Tons 4.6 742 Total Output Btuh/s ft 20.9 Total Output s ft/Ton 574.3 66,869 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm V 2,000 Carrier 25HNB960/FE4ANB006 34,124 11,686 36,538 Airflow cfm/s ft 0.75 36,538 Airflow cfmfTon 432.4 Outside Air % 0.0% Total Adjusted System Output 34,124 11,686 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF /-� 89 OF rn fns � Heating Coil Supply Fan 2,000 cfm 88 °F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0cfm 70/60°F 70/60°F 54/54°F g5/.4J54OF� c Bull D:: ��' ^ ��CC �tl T /A - _ O/Ai-E I DLP I , ° Cooling Coil �'^� 55 / 54 F CSupply an �ppRo 2,000 cfm ECJ FOR COlVSTt3IS°s.:� °%C; ROOM 70/60°F EnergyPro5.1 by EnergySoR User Number: 6712 RunCode: 201405-01715:56:32 /D: Page 26 of 54 4 4 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res System Name HVAC 8 Date 5/1/2014 Floor Area 832 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 269 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 25,400 6,325 1,263 458 8,958 Total Output Btuh 25,400 0 Output Btuh/s ft 30.5 92 102 Cooling System 0 0 Output per System 24,800 0 0 0 0 Total Output Btuh 24,800 0 1,263 0 Total Output Tons 2.1 92 102 Total Output Btuh/s ft 29.8 Total Output s ttrron 402.6 6,508 F 9,161 Air System CFM per System 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 25HNB924/FE4ANB003 18,978 414 15,864 Airflow cfm/s ft 0.96 15,864 Jan 1 AM Airflow cfm/Ton 387.1 Outside Air % 0.0% Total Adjusted System Output 18,978 414 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 91 OF 91 OF i Heating Coil Supply Fan ° 800 cfm 90 F ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 70 / 57 °F 70/57°F 48/47°F 48/47AOF�e e wrt J 9 !AR a�-�. . c _ _ `' ."AIV I_A Supply Fan l� j ,.� DEPT • 48 / 47 OF Cooling Coil 800 cfm FQ O `� R CONS r 1ATE !C` D �CRPOMII �BY 43.8 %70 / 57 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-01T15:56:32 /D: Page 27 of 54 4 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res System Name HVAC 9 Date 5/1/2014 Floor Area 2,749 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,855 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,500 49,366 3,713 2,446 44,071 Total Output Btuh 117,000 0 Output Btuh/s ft 42.6 714 500 Cooling System 0 0 Output per System 55,500 0 0 0 0 Total Output Btuh 111,000 0 714 50,795 3,713 0 Total Output Tons 9.3 500 Total Output Btuh/s ft 40.4 Total Output s ft/Ton 297.2 45,072 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 Carrier 25HNB960/FE4ANB006 70,582 19,911 73,075 Airflow cfm/s ft 1.46 73,075 F Jan 1 AM Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 70,582 19,911 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Tem eratures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF ^^ 89 OF fns Heating Coil Supply Fan 4,000 cfm 89 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 70/59°F 70 / 60 °F 54 / 53 °F 54 / 53=F-�®_® • affg) c o13 Cooling Coil Supply Fan 4ppRo QEPT. 54 / 53 °F 4,000 cfm � C� F° JCLCR DATE 70/59°F --_ Rv EnergyPro 5.1 by EnergySoR User Number: 6712 Run Code: 201405-01715:56:32 ID: Page 28 of 54 • • ROOM LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 System Name Floor Area HVAC 5 1,290 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible Master Master 1 1,416 24,480 1,849 1,416 24,480 1,849 1,374 24,717 I ' Total includes PAGETOT,� iqL=� TOTAL, 1,416 24,480 1,849 11,374 24,717 - 1., 4. _16 _ 24,'480-,1, 849 1, 374 24, 717 17J C� J CJ ROOM LOAD SUMMARY Project Name Lippman Res Date 5/1/2014 System Name HVAC 8 Floor Area 832 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible Theater Theater 1 269 6,325 1,263 269 6,325 1,263 458 8,958 TV d.h c= I A 'rN V TA I -� 1 yIEPT VEA ' Total includes ventilation load for zonal systems. v� V01 t"ucTlom N PAGE TOTALOAt 63 269 6,325 1,2 458X 8,958 E. TOTAL= . , ,, , —269 ,6?.325 1,263 4538 8,958 EneMyPro 5.1 bV EneMySoft User Number: 6712 Run Code: 201405-01715:56:32 /D: Pa a 35 of 54 E-1 • ROOM LOAD SUMMARY Project Name Lippman Res Date 5/1/2014 System Name HVAC 9 Floor Area 2,749 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 2nd Floor 2nd Floor 1 2,855 49,366 3,713 2,855 49,366 3,713 2,446 44,071 r� ' Total includes ventilation load for zonal systems. PAGE TOTAL FOF (2;855�49�366:;_3,713 2,446 44,071 TOTAL2,855 49,366 "3713 2,446 44,071 DATE Ene Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2014-05-01T15:56c32_._._ ID: �_ Page 36 of 54 C � J • L' ROOM HEATING PEAK LOADS Project NameDate Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Maid Quarters Floor Area 993.0 82 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0690 X 0.4900 X 0.5639 X 0.5000 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X to another room Ceiling Height LDII\&C)'& APPROVEn X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 76p AT *F Btu/hr R-21 Wall (W.21.2x6.16) 1,064.4 46 = = = = = 3,378 Fixed -Dual 75.6 46 1,704 Swing Door 40.0 46 1,038 Wood Door 24.0 46 552 Slab -On -Grade perim = 108.0 46 3,627 = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total SA ETY DEPT. Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 993 X Area 10,299 6 = 2,575 TOTAL HOURLY HEAT LOSS FOR ROOM j "J NST 12,873 n I Ene Pro 5.1 6 Ene Soft User Number: 6712 Run Code: 201405-01 T15:56:32�1D — Y Pa a 37 of 54 CJ L_aJ ROOM HEATING PEAK LOADS Project Name Lippman Res Date 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Dining Floor Area 1,455.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X nF �PROVE C ON AT *F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Foam 154.0 X X 0.0260 46 184 R-21 Wall (W.21.2x6.16) 553.0 0.0690 46 1,755 Swing Door 91.8 X 0.5639 46 2,381 Wood Door 24.0 X 0.5000 46 552 Panel Doors 273.2 X X X 0.4500 46 5,655 Slab -On -Grade perim = 80.0 0.7300 46 2,686 X X X X X X X X X X X X X X X X X X X X X X X X to another -room -- CITY 11.50 (Xf' G0276;` Ceiling Height ACH_ FOR Items shown with an asterisk (•) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,455 X Area Page Total LA h6Q•] X - �Y_46' I TO 13,214 1 3,773 TOTAL HOURLY HEAT LOSS FOR ROOM 16,987 DATE BY EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014-05-01T0.-56.-32-0;;.-.— ROOM HEATING PEAK LOADS Project Name Lippman Res Date 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Floor Area 3,377.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OF CONSTRUCT OT °F Btu/hr R-38 Roof Foam 2,536.0 X 0.0260 46 = = 3,033 R-21 Wall (W.21.2x6.16) 895.5 X X 0.0690 46 2,842 Panel Doors 626.1 0.4500 46 = 12,960 Fixed -Dual -Butt 803.1 X 0.6162 46 = 22,764 Horizontal Slider 135.2 X X X X X X X 0.4500 46 = = 2,799 Pocket Door 392.1 0.4800 46 8,658 Slab -On -Grade perim = 114.0 0.7300 46 = = 3,828 = = = X = = X X = X X X = = = X = = X X X X = = = X = X = = X X = X = X X XX X = = = = --- Rage Total LA Q1 EINTA �060,11-EX! Y n ROVED AT mi Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface to X 3,377 X Area Ceiling anothrerroom I CITY J 1470.Ik.i eight A AC,H� APP FOR _ 56,884 6 TOTAL HOURLY HEAT LOSS FOR ROOM 1 65,641 1 DATE -_ BY EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: Page 39 of 54 C� J C ROOM HEATING PEAK LOADS Project NameDate Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Floor Area 1,290.0 ftz Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.4500 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X to anothergroom_ 1 U I Y 17 00 !X jjr0Z-65 CeilingHeight AVA" FOR CONSTRUCTION I X X X X X X X X X X X X X X X X X X X X X X X X. X X X X X X X OF ROe AT °F = = = = = = = = = = = = = = = = = - = = = = = _ = = = = = = = Btu/hr R-38 Roof Foam 635.0 46 759 R-21 Wall (W.21.2x6.16) 798.6 46 2,535 Panel Doors 675.4 46 13,981 Slab -On -Grade pen .m = 122.0 46 4,097 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,290 X Area Page Total_ LA QUINTA t F WIE f DF��46 S AT ED -- 21,372 3,345 TOTAL HOURLY HEAT LOSS FOR ROOM 24,717 DATE �_ BY EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 201405-01715:56:32 /D: Page 40 of 54 Pi �J ROOM HEATING PEAK LOADS Project Name751112014 Lippman Res ate ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Floor Area 1,340.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0690 X 0.4500 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = + 46 Btu/hr R-38 Roof Foam 1,340.0 46 1,603 R-21 Wall (W21.2x6.16) 1,529.6 46 4,855 Panel Doors 270.4 46 5,597 Slab -On -Grade perim = 133.0 X X X X X X X 0.7300 46 4,466 X X X X X X X X X X X X X X X X X X X X X to another Poom ICFI III_D��r� � 12.00 4X --,0.265 Ceilirig Height �Y `ACHV I FOR CONSTRUCTION Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,340 X Area Page Tyot/a�l"� SFC Tl UtF / 60 ]- X AT 16,521 = 3,475 TOTAL HOURLY HEAT LOSS FOR ROOM 1 1 19,996 UA I t —__ By— EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2014-05-01T15:56:32 ID: Page 41 of 54 C • ROOM HEATING PEAK LOADS Project Name Lippman Res Date 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Play Room Bowling Floor Area 2,656.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X (2 yrs— AT °F = = = = = = = Btu/hr R-38 Roof Foam 2,656.0 0.0260 46 3,177 R-21 Wall (W.21.2x6.16) 3,114.7 0.0690 46 9,866 Panel Doors 1,255.5 0.4500 46 25,989 Pivot Door 71.3 0.5639 46 1,849 Horizontal Slider 298.5 0.4500 46 6,179 Slab -On -Grade perim = 340.0 0.7300 46 11,417 Items shown with an asterisk (') denote conduction Infiltration: 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,656 X Area another room Y 14._00 i0.227e- HeidhtUILU%Gi"AT APPRDvx=n Page Total /t 60�], � � R�jilITi46� & SAFETY DEPi'. 58,497 = 6,887 TOTAL HOURLY HEAT LOSS FOR ROOM ) 1 -UH CON ! t��� n�, 1 65,384 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014 -05 -011'15.5i%.12 ------4D,;— BY I Page 42 of 54 ROOM HEATING PEAK LOADS Project Name Lippman Res Date 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Theater Floor Area 832.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X �H� AT `F = c = = = = = = = = = = = = = = = = = - = = = = = = = = = = j4,6 e p Btu/hr R-38 Roof Foam 832.0 X 0.0260 46 995 R-21 Wall (W.21.2x6.16) 972.0 X X 0.0690 46 3,085 Slab -On -Grade perim = 81.0 0.7300 46 2,720 X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 1K4r00 0,.227 Ceiling Heig�itilLl�pNC @-� Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 832 X Area Page Total L.6Q ] X III\Ir SAFETYD�Pj. �y 6,800 a 2,157 TOTAL HOURLY HEAT LOSS FOR ROOM F t�R CQN TRt truer n 8 958 EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 201405-0A1 15}56:•32 ID--_ By I Page 43 of 54 • ROOM HEATING PEAK LOADS Project Name Lippman Res Date 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Floor Area 2,749. 0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area . U -Value AT °F X 46 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Btu/hr R-38 Roof Foam 2,749.0 X 0.0260 3,288 R-21 Wall (W.21.2x6.16) 1,078.2 X X 0.0690 X X X X 46 3,422 Horizontal Slider 304.7 0.4500 46 6,307 Fixed -Dual 208.8 X X X X 0.4900 46 4,706 Pivot Door 94.7 0.5639 46 2,456 Pocket Door 183.0 0.4800 X X X X X X 46 4,041 Panel Doors 614.6 0.4500 46 12,722 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 111.50„ X r 0:276 Ceiling Hei'glit'iLL��ACHi A P Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 2,749 X Area Page Total f/ -EA] QX,,' vA�'=��l ®OT P R O VP n C 36,943 46 PT, 7,128 TOTAL HOURLY HEAT LOSS FOR ROOM �'-uNSTRUGTI t`t I 44,071 DATE� - EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 201405-015.1.5;`56:32 D:— _ I Page 44 of 54 • C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Maid Quarters Outdoor Dry Bulb Temperature 112 OF Floor Area 993.0 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (W.21.2x6.16) (N) 115.0 X 0.0690 X 23.0 = 183 R-21 Wall (W.21.2x6.16) (E) 324.0 X 0.0690 X 33.0 = 738 R-21 Wall (W.21.2x6.16) (S) 320.4 X 0.0690 X 26.0 = 575 R-21 Wall (W.21.2x6.16) (tM 305.0 X 0.0690 X 33.0 = 694 Wood Door (169 24.0 X 0.5000 X 33.0 = 396 X X = X X = X X = X X = Page Total 2,586 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6a (S) 0.0 X 19.4 + 25.4 X 19.5 = 496 6b (S) 0.0 X 23.2 + 40.0 X 23.3 = 930 7 (S) 0.0 X 19.4 + 25.4 X 19.5 = 496 7f (S) 0.0 X 19.4 + 24.8 X 19.5 = 484 X + X - X + X - X + X - X + X - X + X - Page Total 2,405 Internal Gain Btu/hr- tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 54.34 X 42 = 2,271 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,492 Latent Gain Btu/hr Occupants 1.0 Occupants X _ �� ('� j !? ,•9tuh/ c----- ,-,-_ 200 ° . "'�'F' Infiltration: 4,771 X 0.94 X 54.34 X 0.00 23 �ILQINU 8 SAFE7y ®NTA EPT, Air Sensible CFM ELA OW Aja ` RO Fp r ED TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I 1UN r 1 469 EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 201405-01 15:56:32 -ID: Ry Page 45 of 54 • • C RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 1,455.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OFI Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Foam W 154.0 X 0.0260 X 56.0 = 224 R-21 Wall (W.21.2x6.16) (E) 211.2 X 0.0690 X 33.0 = 481 Wood Door (E) 24.0 X 0.5000 X 33.0 = 396 R-21 Wall (W.21.2x6.16) (S) 207.0 X 0.0690 X 26.0 c 371 R-21 Wall (W.21.2x6.16) (tM 134.8 X 0.0690 X 33.0 = 307 X X = X X = X X = X X = Page Total 1,779 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 3 (E) 0.0 X 23.2 + 91.8 X 42.2 = 3,877 12 (lM 273.2 X 17.9 + 0.0 X 32.2 = 4,892 X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 8,768 Internal Gain Btu/hr- tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 79.62 X 42 = 3,328 Air Sensible CFM EIA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,106 Latent Gain Btu/hr @@ Occupants 1.0 Occupants X �rp 20'0. Btuti/occ� = � �UPNT 200 I et _CIfVO Infiltration: 4,771 X 0.94 X 79.62 X �0.000s 31 c �` SAFETY CEP/T4. 1,860 Air Sensible CFM ELA °�PROVE� IpW FOR CONSTRt 1t^ In 1 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I 2,060 DAT EnerovPro 5.1 bv EnemvSoft User Number: 6712 RunCode: 2014 -05=U1 -T1.5.56.3 D: " -�__ 1 Page 46 of 54 F- -N RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Outdoor Dry Bulb Temperature 112 OF Floor Area 3,377.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof Foam R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = - 2,536.0 0.0260 56.0 203.6 0.0690 23.0 134.3 0.0690 33.0 25.7 0.0690 26.0 531.9 0.0690 33.0 28.7 149.1 54.9 0.0 28.7 355.7 54.9 167.2 17.9 188.5 32.2 0.0 28.7 149.1 Page Total Fenestration 18 19 2a 2b 37 46 33 34 13 Internal Gain Orianfatinn (N) (N) (E) (E) (E) (E) (S) (S) (W1 Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.9 135.2 17.9 0.0 17.9 135.2 17.9 0.0 28.7 149.2 54.9 0.0 28.7 149.1 54.9 0.0 28.7 355.7 54.9 167.2 17.9 188.5 32.2 0.0 28.7 149.1 28.8 0.0 17.9 135.2 18.0 392.1 30.4 1 0.01 1 63.6 Page Total 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 184.79 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain _ Occupants 1.0 Occupants X n't t i a20"0 Btuh/ocQ U 1 NTPF 11 " u & SAFETY D D D D 0APPROVEDEPT. X Infiltration: 4,771 0.94 X 184.79 X 000523 Air Sensible CFM ELA fW *1 FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM y ' ter, i BY_ Btu/hr 3, 692 323 306 r 8,190 8,184 19,525 9,055 4,294 2, 428 11,912 Btu/hr 230 0 7,724 81,963 Btu/hr 200 4,316 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,290.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Foam (1/0 635.0 X 0.0260 X 56.0 = 925 R-21 Wall (W.21.2x6.16) (N) 126.3 X 0.0690 X 23.0 = 200 R-21 Wall (W.21.2x6.16) (E) 456.0 X 0.0690 X 33.0 = 1,038 R-21 Wall (W.21.2x6.16) (W) 216.3 X 0.0690 X 33.0 = 493 X X = X X = X X = X X = X X = Page Total 2,656 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 15 (N) 0.0 X 17.9 + 149.1 X 17.9 = 2,670 17 (N) 0.0 X 17.9 + 66.6 X 17.9 = 1,193 14 (M 0.0 X 17.9 + 267.5 X 32.2 = 8,601 16 AM 0.0 X 17.9 + 192.2 X 32.2 = 6,180 X + X - X + X - X + X - X + X - X + X - Page Total 18,644 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 70.59 X 42 = 2,951 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,480 Latent Gain Btu/hr Occupants 1.0 Occupants XN G' 200 Btu�h/occ. 200 BU' -DING & SAFE TY DEPT. Infiltration: 4,771 X 0.94 X 70.59 X 0.00523 P= P 1,649 Air Sensible CFM ELA �AW LOVED FOR CONSTRUCTjop4 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM ' 1,849 DATE Enem yPro 5.1 by EnemySoft User Number: 6712 RunCode: 2014-05.0=35:56:32 67 Page 48 of 54 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,340.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Foam W 1,340.0 X 0.0260 X 56.0 = 1,951 R-21 Wall (W.21.2x6.16) (N) 245.6 X 0.0690 X 23.0 = 390 R-21 Wall (W 21.2x6.16) (E) 384.0 X 0.0690 X 33.0 = 874 R-21 Wall (W.21.2x6.16) (S) 516.0 X 0.0690 X 26.0 = 926 R-21 Wall (W.21.2x6.16) (W) 384.0 X 0.0690 X 33.0 = 874 X X = X X = X X = X X = Page Total 5,015 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 20 (N) 0.0 X 17.9 + 135.2 X 17.9 = 2,421 21 (N) 0.0 X 17.9 + 135.2 X 17.9 = 2,421 X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 4,842 Internal Gain Btu/hr- tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/OCC. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 73.33 X 42 = 3,065 Air Sensible CFM ELA 5T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,152 Latent Gain r._ Btu/hr _ Occupants 1.0 Occupants X (^,ice X200: Btuh/occ` = 200 I Pt t�A DING SAFETY DEPT Infiltration: 4,771 X 0.94 X 73.33 X 10.0O523 - 1,713 Air Sensible CFM ELA[DW APPRO ED 1I FOR CONSTRU Tlnnl TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1 1,913 A EnerovPro 5.1 bv Enemysoft User Number: 6712 Run Code: 2014-05 0 15:56:32 10- Oy. 54 I RESIDENTIAL ROOM COOLING LOAD SUMMARY rrujeci rvarne Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Play Room Bowling Outdoor Dry Bulb Temperature 112 OF Floor Area 2,656.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof Foam R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (E) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = =, = = = - 2,656.0 0.0260 56.0 41.3 0.0690 23.0 923.2 0.0690 33.0 430.4 0.0690 26.0 1,719.8 0.0690 33.0 17.9 90.2 32.2 80.0 17.9 90.2 32.2 80.0 17.9 90.2 32.2 80.0 17.9 90.2 Page Total Fenestration 24 24c Above 22 27 28 29 30 26 d 26 f Internal Gain Orientation (N) (N) (N) (E) (E) (E) (E) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.9 294.8 17.9 0.0 17.9 144.7 17.9 0.0 17.9 135.2 17.9 80.0 17.9 90.2 32.2 80.0 17.9 90.2 32.2 80.0 17.9 90.2 32.2 80.0 17.9 90.2 32.2 56.8 23.2 0.0 23.3 0.0 23.2 1 14.5 23.3 Page Total 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,600 Btu = Infiltration: 1.064 X 0.94 X 145.34 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 1.0 Occupants X Fwgo` �Btuhh/o' .p Z a p I r, rT4 Infiltration: 4,771 X 0.94 X 145.34 X O.Q0523t ILDING & SAFETY DEPT, Air Sensible CFM ELA A APPROVED 01 FOR CONSTRU Inns TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I- Btu/hr 3,867 66 2,102 772 3,916 723 r 2,5911 2,421 4,333 4,333 4,333 1,317 337 29,2761 Btu/hr 230 0 6,075 52,934 Btu/hr 200 3,394 • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Play Room Bowling Outdoor Dry Bulb Temperature 112 OF Floor Area 2,656. 0 ftZ Outdoor Wet Bulb Temperature' 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 32 (S) 128.3 X 17.9 + 0.0 X 18.0 = 2,297 31 (tM 80.0 X 17.9 + 90.2 X 32.2 = 4,333 X + X = X + X - X + X - X + X - X + X - X + X - X +1 X - Page Total 6,630 Internal Gain Btu/hr— tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 145.34 X 42 = 6,075 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 52,934 Latent Gain_ Btu/hr Occupants 1.0 Occupants X r,1TV00 Btuh/o INI_A 200 a BUiLDINO & SAFETY DEPT_ Infiltration: 4,771 X 0.94 X 145.34 X 0.00523= Air Sensible CFM ELA AWAPPROVED FOR CONSTRI I .Tt I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM I 3,594 n-ri Ene Pro 5.16 EnerSoft User Number: 6712 Run Code: 2014-05-017.5:56:32 �D -- Page 51 of 54 r1 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name Theater Outdoor Dry Bulb Temperature 112 °F Floor Area 832.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof Foam (I'M 832.0 X 0.0260 X 77.0 = 1,666 R-21 Wall (W.21.2x6.16) (N) 324.0 X 0.0690 X 31.0 = 693 R-21 Wall (W.21.2x6.16) (E) 324.0 X 0.0690 X 44.0 = 984 R-21 Wall (W 21.2x6.16) (S) 324.0 X 0.0690 X 38.0 = 850 X X = X X = X X = X X = X X = Page Total 4,192 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X + X - X + X - X + X - X + X - X + X - X + X - X + X - X + X - X + X - Page Total 0 Internal Gain Btu/hr— tu/hrOccu Occupants ants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.94 X 45.53 X 42 = 1,903 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,325 Latent Gain (dA 0 � �, Btu/hr rr-Occupants 1.0 Occupants X 13t 120•,01 Btuh/occ�� �����i� �� & SAFETY 200 DEPT, Infiltration: 4,771 X 0.94 X 45.53 X 0.00 3 =APPROVED 1,063 Air Sensible CFM ELA ow FOR CONSTRUCTION TOTAL HOURLY LATENT HEAT GAIN FOR ROOM T—DATF 1,263 EnerovPro 5.1 b -v EnemySoft User Number: 6712 Run Code: 201405-01715:56:32 /D: Pa a 52 of 54 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 2,749. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranqe: 34 OF Opaque Surfaces R-38 Roof Foam R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (E) (S) Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,749.0 0.0260 56.0 174.8 0.0690 23.0 512.3 0.0690 33.0 246.3 0.0690 26.0 144.8 0.0690 33.0 19.4 18.9 34.9 51.9 23.2 0.0 23.3 6.4 30.4 0.0 30.5 0.0 30.4 91.1 Page Total Fenestration 48 40 40c above 43 f 39 39c above 41 41c above 42 Oriantatinn (N) (E) (E) (E) (S) (S) (S) (S) (S) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.01 17.9 135.2 17.9 0.0 17.9 169.5 32.2 0.0 19.4 112.5 34.9 16.8 19.4 18.9 34.9 51.9 23.2 0.0 23.3 6.4 30.4 0.0 30.5 0.0 30.4 91.1 30.5 0.0 23.2 21.4 23.3 0.0 F 30.4 1 85.5 F 30.5 Page Total Internal Gain 1.0 Occupants X 230 Btuh/occ. 0.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 )( 0.94 )( 150.43 X 42 = Air Sensible CFM ELA AT Btu/hr 4,003 277 1,167 442 330 6,218 Btu/hr 2,421 5,450 3,925 986 1,203 194 2,780 498 2,609 20,066 Btu/hr 230 0 6,288 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM as.sss Latent Gain 1.o Occupants X Infiltration: 4,771 X 0.94 X 150.43 X 0.00523 Air Sensible CFM ELA AW 0 TOTAL HOURLY LATENT HEAT GAIN FOR ROOM R _T_" r'-Btulhr >oo -Bt OF c. LA -Q U QUIN, tl � 200 �&11Mu SAFETY ® F-11 PPri 3,513 FOR CONSTRUCTION B • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 5/1/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 2,749. 0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces' . Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 42c above (S) 21.4 X 23.2 + 0.0 X 23.3 = 496 43 door (IM 165.1 X 17.9 + 43.9 X 32.2 = 4,368 43c (IM 47.9 X 19.4 + 12.7 X 34.9 = 1,375 44 (W) 63.5 X 17.9 + 71.7 X 32.2 = 3,442 45 (IM 63.5 X 17.9 + 71.7 X 32.2 = 3,442, 47 (IM 63.5 X 17.9 + 71.7 X 32.2 = 3,442 X + X - X + X - X +1 X - Page Total 16,564 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 x 0.94 X 150.43 X 42 = ....._6288 Air Sensible CFM ELA AT CIT +, F�.IIL TA D , T" n. -r - TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM P "-` °49,366 FO f' '�- t Latent Gain , . Btu/hr Occupants 1.0 Occupants X E200Btuh/occ. Infiltration: 4,771 X 0.94 X 150.43 X Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3.71 EnemvPro 5.1 by Ene Soft User Number: 6712 RunCode: 201405-01T15:56:32 ID: Page 54 of 51 &'Electronically Filed,by Tim Scott and Authenticated'at CalCERTS.com .,`6/17/2013' it -' Electronically Signed at Ca10ERTS:com,by'Tammy, Jenkins (Discovery Builders California) 6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R1, Project Name Lippman Res 'Project Address Lot 101 & 102 Baffin Ave. La Quinta Buil ding`Type m Single Family ❑Addition Alone. • - ❑ Multi Family ❑ ti / I California Energy Climate Zone IKA, F CA Climate Zone 15 2 n/a Date. 6/17/2013 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST _ UL 0 3 2013 ❑ Yes ❑ No HERS Measures --- If Yes, A CF -4R must be provide per Part 2 of 5 of this form. El Yes ❑ No. Special- Features -7 If Yes, see Part 2 of 5 of this f ' INTA . INSULATION, Area • Spec9UNYTY DEV Construction Type Cavity Features see.Part 2 of 5 . Status Wall Wood Framed R-21 91753 © _ Slab- Unheated'Slab-on-Grade None 11,563 n1' Ne „ Roof Wood Framed Attic R-38 •11, 563 Rad' t R Ne Door Opaque Door None 48 ' Net, FOR CONSTRUGTNO&V Q1 J I 2m- IFENESTRA In Orientation' Tl A ea CF ctor SHGC Exterior Overhang Sidefins Shades Status ' Right (N) 1,687.0 0.390 0.28 none none Bug Screen New Fronti(E) 1,100 0 '. 0 390 _ 0 2 none none . Bug Screen New '5yaw, k •z '+:•&, '�.:'d:�f+ I w*.. :raid �`-� � Rear (lA�� . 11'330.0 03 0 0 28• 30 0 Honey Bug Scre' :; - New i ..fir. `*. -,�f �:..�T :i,, ... ... Left (S) X440 0 0 390, 0 28 none none Bug Screen i New Rear ( (,y) . ' ,+-i 7¢0 0, 0390 " ,, ;. 028 X14 0 ,.:none _ Bug Screen Rear (lM 416 0 0390 0 28 none-, �<none; BugSrreen New Front (E)"—"�'� one Bug Screen New _ 140.0 ;F 0 390 0.28 6.0 none Bug Screen New Rear (►M600 0 .,0.390 i 0.28 6.0 none Bug Screen New ` Rear (VIO 220 0 0.390' 0.28 10.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff, ' Cooling Min: Eff Thermostat ' Status 1, Split Heat Pump 10.00 HSPF Split Heat Pump • 18.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF , Split Heat Pump 16.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location _ ` He'ating Coolin • _Duct Location . R -Value ' Status HVAC 1 • Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 i4 Ducted' Ducted Attic, Ceiling Ins, vented 8.0 . New WATER HEATING Ot . Type ' . Gallons Min. Eff. Distribution Status 3 Large Gas - .100 0.80 'All Pipes Ins New ` EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Pae 1 of 14 ?reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc ��El'ectronically Filed by TimScottand Authenticated at Ca10ERTS.com - 6/17/2013 Electronically Signed at Ca10ERTS.com by Tammy- Jenkins (Discovery Builders California) 6/17/2013 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16, HERS Provider: Ca10ERTS, Inc 'Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/,17/2013 -Electronically Signed.at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 EnergyPro 5.1 ?1 EnergySoft User Number: 6712 RunCode: 2013-0&17T10:25:56 ID: Page 3 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Prov ider:.Ca10ERTS, inc PERFORMANCE CERTIFICATE: Residential Part 1 of 5)r CF -1 R Project Name Building Type m Single family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 1611712013 'Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Stories Lot 101- & 102 Baffin Ave. La Quinta CA Climate Zone 15 14,512 n/a 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -411 must be provided per Part 2 of 5 of this form. 23 Yes ❑ No. Special Features =- If Yes, see Part 2 of 5 of this form for details. INSULATION. Area Special Construction Type Cavity Features see Part 2 of -5 Status FENESTRATION::` U- Exterior Orientation .....,Area Factor SHGC Overhang Sidefins Shades Status ":• - Win, �.t_ . _ . i� xi � �. • Al � � � .. •�..::�., �� �e ..,_ ., .:.`fi ....rsA. ,u .+Y',GFF� a .�.. _ .Y . .„F• _' HVAC'SYSTEMS Qt . Heating Min. Eff Cooling Min. Eff Thermostat. Status 1 Split Heat Pump. 10.00 HSPF Split Heat Pump 18.0 SEER. Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status` . HVAC 8 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 9 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff ' Distribution Status EnergyPro 5.1 ?1 EnergySoft User Number: 6712 RunCode: 2013-0&17T10:25:56 ID: Page 3 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Prov ider:.Ca10ERTS, inc Electronically Tiled by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 Electronically Signed at CalCERTS.com by Tammy 'Jenkins (Discovery Builders California) -6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Building Type ® Single Family ❑ Addition Alone ' Date Lippman Res ❑ Multi Family O Existing+Addition/Alteration 6/17/2013 SPECIAL FEATURES INSPECTION .CHECKLIST The enforcement agency should pay special attention to the•items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the.justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted.' The DHW System Bradford -White Corp. M-1-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. " The HVAC System HVAC 1 must serve only'Steeping Areas. The non closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat.' In addition the air flow requirements and fan watt draw re uirements in Residential Appendix RA3.3 must be met., HIGH MASS Design - Verify Thermal Mass: 98.0 fl2 Covered Slab Floor, 3.500" thick at Maid uarters HIGH MASS Design -.Verify Thermal Mass: 895.0 fl2 Exposed Slab Floor, 3.500" thick at Maid Quarters The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 stand each zone must'have a se arate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH ASS Design - Verify Thermal"Mass: 280.0,ff Covered Slab -Floor, 3.500" thick at Kitchen & Dining HIGH MASS Design'- Verify Thermal. Mass: 1,175.0 tt2 Exposed Slab Floor 3.500" thick at Kitchen & Dining The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the'air.:.;flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH M SS Design - Verify ThermahMass: 2,547.0 ft2 Exposed Slab Floor, 3.500"thick at Living - The HVAC System HVAC 5 must seNe only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate"therrri0stati4h addition the airflow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design -Verify Thermal Mass 994:0 ti= Covered Slab Floor, 3:500" thick at Master S • .. ,:. a - HIGH MASS Design Verify Thermal ass 396 Oktt' Exposed Slab FloTor 3 500 threkzat Master 1 ... _�":: k ..�Y .."),: "Et, i4 k5.b. c '�b"x'u'•'' �x+�.ft 't i!!� must serve only.YSI6eying Areas- ` TFie non-closable'rO eafbetW666 zones cannofexceetl 40 sf and;each zone must have a The HVAC!System HVA C`6'& se crate thermostat. In addition the air:BoW1ra uirements a nd}far,watt.drew re wrementsanlResrdenhal:'A endix R93 3:must?be,met •HERSiREQUIRED VERIFICATION4S.6-mirycettlfled�HERS RaerThe Inspector must{receive a ,.�.. " com leted CF..4'R.form`foreach of the.imeasures:fisted=l elow'for:flnatto be Iver: The Cooling Systema Carrier 25HNB924/FE4ANB003 includes credit fora 13.5 EER" Condenser. A certified HERS rater must field verify the installation of the coirecRCondenser j '. Th.. hSysterim HVAC'fincludes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. r The HVAC System HVAC 1 incorporates;! HERS Verified Refrigerant Charge ora Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate'airflow. A certified HERS rater must diagnostically measure airfldw of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB960/FE4AN8006 includes credit, for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser.' The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. - The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. ' The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. EnergyPro 5.1 by EnemySoft User Number. 6712 RunCode: 2013-06-17710:25:56 ID: Page 4 of 14 Reg: 213-N0035232C-000000000=0000 Registration'Date/Time: 2013/06/06 17:14:16 HERS -Provider: CalCERTS, Inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 --Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name Building Type ® Single Family O Addition Alone Date. Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcementagency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 990.0 ft2 Covered Slab Floor, 3.500" thick at Guest 1 & 2 HIGH MASS Design - Verify Thermal Mass: 450.0 ft2 Exposed Slab Floor, 3.500" thick bt Guest 1 & 2 The HVAC System HVAC 7 must serve only Living Areas. The non -closable area between zones'cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - "Verify Mass: 2,570. 0 ft2 Covered Slab Floor, 3.500" thick at Play Room Bowling HIGH MASS Design - Verify Thermal Mass: 286.0 ft2 Exposed Slab Floor, 3.500" thick at Play Room Bowling The HVAC System HVAC 8 must serve only Living -Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a ments and fan watt draw requirements in Resider; Appendix RA3.3 must be met. separate thermostat. In addition the air flow re uirentia HIGH MASS Design -Verily ThermalMass: 882.0 ft2 Covered Slab Floor, 3:500" thick at Theater The Roof R-38 Roof(R.38.204.16),includes credit fora Radiant Barrier that is Continuous meeting eligibility and installation• criteria as specified in Residential A endix RA4.2.2. t' is 3 .. `-�'.#:.. ,n:,�'%i^ �w jar.. nr t� L , `"'• . 145* .. ':...E , r _ • M ;. SREQUIREDVERIFICATION� F HER Items In;thi'We Uon require field testing and/or vdriflcatlonfi by a�cert Hed°HER$ Rater The Inspector must'receive a - ,,. coni Iefed.CF..,4R form for each,of",thee. easures listed below for final to be° Iven: The HVAC SystemsHVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or Charge Indicator Display. The HVAC System HVAC 3 & 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System 9 The HVAC System HVAC 3 &14 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria:; The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure ai ow of the 'HVAC System. ' . The HVAC.System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria The Cooling System Carrier 25HNB960/FE4ANB006 includes credit for a 12.5 EER Condenser. A -certified HERS rater must field verify the installation of the,correct Condenser. The HVAC System HVAC 6 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 wlcf n. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the H VAC System. EnemvPro 5.1 by Enemysoft User Number. 6712 RunCode: 2013-06-17T10c25:56 ID: Page 5 of 14 Reg: 213'-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:,16 HERS Provider: CalCERTS, inc Electronically Filed by Tim Scott and Authenticated at CalCERTS.com -•6/17/2013 ,Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 •r PERFORMANCE -CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name + ' Lippman Res Building Type : ®Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines, the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted- - _ i3 .: - ^4 .{, ae ' PP .i�..,. ..�: .d. 'd•fi"`"Ebritifi�Y3.„ HHH HERS REQUIR Y' VZERIEICATION r . ,v 'CF 4Rm or eal haoffithe s e I dtbelow for fmalto¢be d9tin rifictifi�ffijmbRSR ater Inspector must receive a oomslinithig, iii letedndlors The HVAC System HVAC 6 incorporates HERS verified Duct Leakage.'HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria _ M1. The Cooling System amer 25HNB96WPE4ANB006 includes credit for a 12.5 EER'Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 includescredit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. ".c*�::; The HVAC System'HVAC 7 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC 77 System. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB924/FE4ANS003 includes credit for a 13.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. , The HVAC System HVAC 8 includes credit for Verified Fan Energy. Measured Fan Energy may not:exceed 0.58 w/cfm. The HVAC System HVAC 8 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display: The HVAC System HVAC 8 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 8 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. , v Ene Pro5.1 6 Ene ' SoR. • User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Page 6 of 14 Reg::213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider:-Ca10ERTS,,Inc r Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/201.3 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery'Builders California) 6/17/2013 . PERFORMANCE CERTIFICATE: Residential-., Part 2 of 5 CF -1 R Project Name Building Type • 2 Single Family ❑ Addition Alone Date Lippman Res ❑Multi Family ❑Existing+'Addition/Alteration 6/17/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The`enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. T • • Nom+:..". .. ! Arm .. :!' Yli .A`�"4 1i:.... :3:A .> :v« #4a.�? '.,'.. ek33 —WON: �(.+`•°w..16sA:ew .. „`,. mak.':. ,, .. 5 ., ;,� .a ',bYSp .. 1 PiN' .Ask'v •p4 ,"' ::3'. �p'-1. 4s..T ,� f _ r... r f'_i: HERSR!REQUIRED 1/ERIFICATION ' Items m,thls sect)on�req,ulre,fleld test)ng antl/oreveriflcatlon by a certfledtHERS Rater TheNnspector mustxreceive a coni leted CF ' form for each of the measuresalsted'l clow fgr final to be Iven ' The HVAC System HVAC 9 includes creditfor Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 9 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 9 includes`credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC IN System. i The HVAC System HVAC 9 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. t �• r EneM yPro 5.1 by EnemySoft, User Number. 6712 RunCode: 2013-06-17710:25:56 ID: Pae 7 of 14 Reg:M(213-N0035232C-000000000-0000 'Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, inc r Electronically Filed by'Tim Scott and Authenticated at'Ca10ERTS.com --6/17/2013 `'ETectronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 Reg! '213'-N0035232C-000000000-0000" Registration Date/Time: 2013'/06/06"17:14:16 r'HERS Provider: Ca10ERTS„ Inc PERFORMANCE CERTIFICATE: Residential Part 3 of 5 , CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ', 0 Multi Family . ❑ Existing+ Addition/Alteration 6/17/2013 ANNUAL ENERGY. USE SUMMARY Standard Proposed Margin •TDV kBtu/ft2- r Space Heating - . 3.95 4.86 -0.91 , Space Cooling 52.77 46.56, 6.21 , Fans . 10.16 11.86 -1.71 , Domestic Hot Water ` 2.51 1.69 0.82 r Pum s 0.00 0.00 0.00 Totals 69.38 64.97 4.41 Percent Better Than Standard: 6.4 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) - 5,393 1,820 Fuel Available�at Site: Natural Gas (S) 2,709 580 Raised Floor Area:. o (►M a' ; 5,415 2,326. Slab on Grade Area: 11,563 (N) 2,697 1,687 Average Ceiling Height: 12.7 ` Root,, 11,563 0 Fenestration Average U Factor: 0.38 TOTALS: 6,413 ,:_..._......._........ Avera a SHGC �.. 0.28 Fenestration/CFA Ratio: 44.2 % REMARKS 4;W rt Th&.,Madison Club Country Club Lots�101 & 102 i 31 STATEMENT OF COMPLIANCE , This rtiflca cefe of compliances lists; the building features and specifications needed to comply with Title 24PmrtsT1 `gthe Administrative Regulations and Part'6 the - Efficiency Standards of thek.California Code.of Regulations. The documentation author hereby certifies that the documentation is, accurate and complete. Documentation Author Company ScottttDesign and Title 24, Inc, ' u 6/17/2013 Address 77-085 Michigan Drive Name .Tim Scott Cit•/State/Zi Palm Desert, Ca 92211 Phone (760) 200-4780 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set• of construction documents is consistent with the other compliance forms -and .worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by,an approved HERS rater:. r' Designer or Owner (per Business & Professions Code) Company Giannetti Architecture & Interiors, Inc. t Address x'.11-980 San Vicente BI Ste 101 Name Giannetti Architecture &Interiors -° City/State'/Zip L.A., CA 90049 Phone (310) 820-1329 Signed License # Date Erie Pro 5.1 b Energ SoR • User Number: 6712 � RunCode: 2013-06-17710:25:56 ID: Page 8 of 14 Reg! '213'-N0035232C-000000000-0000" Registration Date/Time: 2013'/06/06"17:14:16 r'HERS Provider: Ca10ERTS„ Inc PERFORMANCE CERTIFICATE: Residential Part 3 of 5 , CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ', 0 Multi Family . ❑ Existing+ Addition/Alteration 6/17/2013 ANNUAL ENERGY. USE SUMMARY Standard Proposed Margin •TDV kBtu/ft2- r Space Heating - . 3.95 4.86 -0.91 , Space Cooling 52.77 46.56, 6.21 , Fans . 10.16 11.86 -1.71 , Domestic Hot Water ` 2.51 1.69 0.82 r Pum s 0.00 0.00 0.00 Totals 69.38 64.97 4.41 Percent Better Than Standard: 6.4 BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) - 5,393 1,820 Fuel Available�at Site: Natural Gas (S) 2,709 580 Raised Floor Area:. o (►M a' ; 5,415 2,326. Slab on Grade Area: 11,563 (N) 2,697 1,687 Average Ceiling Height: 12.7 ` Root,, 11,563 0 Fenestration Average U Factor: 0.38 TOTALS: 6,413 ,:_..._......._........ Avera a SHGC �.. 0.28 Fenestration/CFA Ratio: 44.2 % REMARKS 4;W rt Th&.,Madison Club Country Club Lots�101 & 102 i 31 STATEMENT OF COMPLIANCE , This rtiflca cefe of compliances lists; the building features and specifications needed to comply with Title 24PmrtsT1 `gthe Administrative Regulations and Part'6 the - Efficiency Standards of thek.California Code.of Regulations. The documentation author hereby certifies that the documentation is, accurate and complete. Documentation Author Company ScottttDesign and Title 24, Inc, ' u 6/17/2013 Address 77-085 Michigan Drive Name .Tim Scott Cit•/State/Zi Palm Desert, Ca 92211 Phone (760) 200-4780 Si ned Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set• of construction documents is consistent with the other compliance forms -and .worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by,an approved HERS rater:. r' Designer or Owner (per Business & Professions Code) Company Giannetti Architecture & Interiors, Inc. t Address x'.11-980 San Vicente BI Ste 101 Name Giannetti Architecture &Interiors -° City/State'/Zip L.A., CA 90049 Phone (310) 820-1329 Signed License # Date Erie Pro 5.1 b Energ SoR • User Number: 6712 � RunCode: 2013-06-17710:25:56 ID: Page Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5) CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611712013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix FactorCavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wail 90 0.069 R-21 0 90 New 4.3.1-A6 Maid Quarters Wall 158 0.069 R-21 90 96 New 4.3.1-A6 Maid Quarters Wall 436 0.069 0-21 180 90 New 4.3.1-A6 Maid Quarters Wall 329 0.069 R-21 270 90 New 4.3.1-A6 Maid Quarters Slab 98 0.730 None 01 180 New 4.4.7-A1 Maid Quarters Slab 895 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Roof 154 0.026 R-38 270 0 New 4.2.1-A9 Kitchen & Dining (Nall 273 0.669 R-21 90 90 New 4.3.1-A6 Kitchen & Dining Wall 1830.069 R-21 180 90 New 4.3.1-A6 Kitchen & Dining Door 24 0.500 None 180 90 New 4.5.1-A4 Kitchen & Dining Wall 78 0.069 R-21 270 90 New 4.3.1-A6 Kitchen & Dining Slab 280 0.730 None 0 180 1 New 4.4.7-A 1 Kitchen & Dining Slab 1,175 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Roof 2,547 0.026 R-38 270 0 New 4.2.1-A9 Living Wall 10 0.069 R-21 0 90 New 4.3.1-A6 Living Wall 424 0.069 R-21 90 90 New 4.3.1-A6 ILiving FENESTRATION SURFACE DETAILS ID Type Area LI -Factor' SHGC Azm I Status Glazing Type Location/Comments 1 Window 25.0 0.390 NERC 0.28 NFRC 0 New Double Non -Metal Tinted Maid Quarters 2 _: Window 48.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 3 Window - 72.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 4: Window 40.0 6.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 5 i Window , . , ._, 6.0 0.390 NFRC_. _0:28_ NFRC _;, .,_ , _ 90 New.___... , Double Non-MetakTinteMaid Quarters 6 Window'"�v --N30.0 0.390 �NFRC,r+ ' 0.28 ,NFRC,,_ ' 90 New,; ) Double Non=Met6VT1ntdd,: %, Kitchen & Dining 7 Window X24.0 0 390 NFRC °',F0.28 WFIRC90New;. J t r Double N'n=MetalTinted ,? ,_ * Kitchen,& Dining 8 endow 330.9- +:0:390 NFRC f ` ' 0.28 NFRC u;, - , "270 New-„ 'Double Non --Metal Tinted,. , Kitchen & Dining 9 window 162101 0.390 NFRC. -, 0.28 NFRC it 0 New '> ,Double Non -Metal Tinted. ' :w living 10 Window jif,162A.ji 0.390 NFRC,,� 0.26 NF,.RC, _ 0iNew4-,Vi Double"Non-MetalTinted f,g Living"V,6 11 Wndom09 f 1140.0 ; 0.390 NFRC ft. +,•-r0:28 NFRCw0 New `: Double `Non -Metal Tintedt`/ 12' Window 140.0 0.390 NFRC " 0.28 NFRC 90 New Double Non -Metal Tinted Living 13 Window 80.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 14. Window 140.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 15 Window 360.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 16 ` Window 140.0.%,0.390 NFRC 0.28 VF -RC1 80 New 157ouble Non -Metal Tinted I Living (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Ove hanq Left Fin H t Wd Len H t LExt RExt Dist Len I Ri ht Fin H t Dist Len I Hat 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 10.0 33.0 30.0 0.1 30.0 30.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bua Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 1 0.76 EnergyPro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Page 9 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: Ca10ERTS, Inc Electronically Filed by Tim Scott and Authenticated at Ca10ERTS.com - 6/17/2013 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 ft CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project NameBuilding Lippman Res Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/17/2013 OPAQUE SURFACE DETAILS Surface U -Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4. Location/Comments Wall 56 0.0699-21 180 90 New 4.3.1-A6 Livin Wall 164 0.069 R-21 270 90 New 4.3.1-A6 Living Slab 2,547 6.730 None 0 180 New 4.4.7-A1 Living Roof 635 0.026 R-38 270 0 New 4.2.1-A9 Master Wall 122 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 456 •0.669 R-21 90 90 New 4.3.1-A6 Master Wall 260 0.069 0-21 270 90 New 4.3.1-A6 Master Slab 994 0.730 None 6 180 New 4.4.7-A 1 Master Slab 396 6.730 None 6 180 New 4.4.7-A1 Master Roof 1,440 0.026 R-38 270 0 New 4.2.1-A9 Guest 1 & 2 Wall • 156 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.669 R-21 90 90 1 New 4.3.1-A6 Guest 1 & 2 Wall 416 0.'069 R-21 186 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 270 90 New 4.3.1-A6 Guest 1 & 2 Slab 990 0.730 None 0 180 New 4.4.7-A1 IGuest 1 & 2 Slab 456 0.730 None 0 180 New 4.4.7-A1 IGuest 1 & 2 FENESTRATION SURFACE:DETAILS ID Type ' Area s'U-Factor SHGC Azm Status Glazing Type Location/Comments 17 . Window 400.0: 0.390 NERC 0.28 NFRC 270 New Double Non -Metal Tinted Living 48-:, Window 360.0 0.390 ;NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Living 19 Window' 40.0 0.390 NFRC. 0.28 NFRC 0 New Double Non -Metal Tinted Master 20, Window 40.0 6.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Master 21.E Window. - --- ..140.0 .0.390 0;28, NFRC _„ __.. 0 New.._ Doub/e_Non-MetaL Tinted ... Master _ ej 270:0. 0.390 NFRC ` 0.28 ;NFRC X270 New f Doutite Non -Metal „T,inted.°, ", Master 22 Wndgw _ - 23 . endow "-56.0 0.390 NFRC' - '9.28 NFRC ,` ,7f.:276 New, ';` DoubWN n-MetalTi ted`i`-' { � Master.,.. . 24 Wridowr 90 0_ 0.390 NFR, C -?' 0.28 NFRC' X270 New; i; 'Double Non3Metal T�nfed:,'� Master -:.. 25 ; Window 40;0 0 390 ;NFRC a i' 0.28 NFRC• =, «, , 0 New. ,Double: Non-Nletal Tinted'- 'Gue''t'132-;,. 26_7_-7,.,08Q.0; Vlbndow °,0.390,' NFRC `i ... 0 28! 'NF,RC;? 0::0' New ; ^ fi Doub/e•Non-Metal Tinted` ,Guestpl 832'„+ " T 27 ` Wndo`NF_RCf_ `` New"t' 4, Double:Non=Metal�Tinted i? ;Guest 1'&,2 26r' r100 0 0:390: 'NFRC ' 0..28' :NFRC"°`�" :_ „:180 New -R" ' ` 'DoubleNon=Metal Tinted., GuestI & 2 29 ;.140.0 0.390 NFRC :"28 NFRC 0 New Double Non -Metal Tinted Pla Room Bowlin30, UWhd6W' 280.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Play Room Bowling 31 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Play Room Bowling 32 180:0; ':..0.281 ;NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling (1) U -Factor Type ' X11.6 -A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T e: 1'.1'6;B =:Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shadelype SHGC HM Wd Ove hang Left Fin Ri ht Fin Len HqL LExt RExt Dist I Len H t Dist Len H t 17 Bug Screen 0.76 10.0 40.0 14.0 0.1 14.0 14.0 18 Bug Screen 0.76 10.0 36.0 14.0 0.1 14.0 14.0 19 Bug Screen . 6.76 , 20 Bug Screen 0.76 21 Bug Screen 0.76 22 B ug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 BugScreen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Buq Screen 0.76 31 Bug Screen 6.76 32 IBug Screen 1 0.76 10.0 18.0 6.0 0.1 6.0 6.0 EnergyPro 5.1 by Ener Soft. User Number: 6712 . RunCode: 2013-06-17710:25:56 ID: ' Pae 10 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc s Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone O Multi Family 0 Existing+ Addition/Alteration Date 6/17/2013 OPAQUE SURFACE DETAILS Surface Type Area U -Insulation Factor Cavit Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 2,956 0.026 R-38 270 0 New 4.2.1-A9 P/az Room Bowlin Wall 28 0.069'R-21 0 90 New 4.3.1-A6 ffaZ Room Bowling Wall 860 0.669 R-21 90 90 New 4.3.1-A6 Play Room Bowling Door 24 0.500 None 90 90 New 4.5.1-A4 Play Room Bowling Wall 490 0.069 R-21 1801 90 New 4.3.1-A6 Play Room Bowling Wall 1,710 0.069 R-21 270 90 New 4.3.1-A6 Play Room Bowling Slab 2,570 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Slab 286 0.730 None 0 180 New 4.4.7-A1 Pla Room Bowling Roof 882 0.026 0-38 270 0 New 4.2.1-A9 Theater Wall 324 0.069 R-21 0 90 New 4.3.1-A6 Theater Wall 324 0.069 R-21 90 90 New 4.3.1-A6 Theater Wall 324 0.069 R-21 180 90 New 4.3.1-A6 Theater Slab 882 0.730 None 6 180 New 4.4.7-A 1 Theater Roof 2,949 0.0260-38 270 0 New 4.2.1-A9 2nd Floor Wall 280 0.069 R-21 6 90 New 4.3.1-A6 2nd Floor Wall 670 0.069 R-21 96 90 New 14.3.1-A6 12nd Floor FENESTRATION SURFACE DETAILS ID Type Area 1,LI-Factor' SHGC2 Azm Status G.lazi,ng Type Location/Comments 33 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 34 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 35 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 36 Window 140.0 0.390 NFRC 0.28 NFRC 186 New Double Non -Metal Tinted Play Room Bowling 37 Window 180.0 0.390 NFRC 0,28 NFRC 270 New Double Non-Metal.Tinfed .-- Play Room Bowling 38 Window` 30.0 0.390 NFRC,.-' 6.28 NFRC 0 New Double Non -Metal Tinted 2nd Floor 39 Window 130.0 0.390 NFRC 0.28 NFRC 90 New Double N n -Metal Tinted 2nd Floor 40 Window 30.0: 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted 2nd Floor 41 Window 30.6 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted 2nd Floor 42 Window t .100.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted 2nd Floor 43 Window 70.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted 2nd Floor 44 Window 220.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 45 Window 140.0 0.390 NFRC 6.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 46 Window 140.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 47 Window 140.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len _±! t LEA RExt Dist Len Ri ht Fin H t Dist Len Hot 33 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 34 Bug Screen 0.76 10.0 18.0 6.0 6.1 6.0 6.0 35 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 36 Bug Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 37 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.0 6.0 38 B, uq Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bu Screen 0.76 42 Bua Screen 0.76 43 Buo Screen 0.76 44 Bug Screen 0.76 10.0 22.0 10.0 0.1 10.0 10.0 45 Buq Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 46 Buq Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 47 Bug Screen 0.76 10.0 14.0 6.0 0.1 6.0 6.0 Ener Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Pae 11 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, inc Ll'ectronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 •Electronically Signed at CalCERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 CERTIFICATE'OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res ❑ Multi Family ❑ Existing+ Addition/Alteration 1611712013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix " Type Area Factor qCavityExteriorFrame Interior Frame Azm Tilt Status 4 Location/Comments Wall 200 0.069 180 90 New 4.3.1-A6 2nd Floor Wall 164 0.069 270 90 New 4.3.1-A6 2nd Floor FENESTRATION SURFACE;DETAILS ID Type Area U Facfor SHGC Azm Status Glazing Type Location/Comments "Ca10ERTS, Inc Reg: 213-N0035232C-000000000-0000, Registration Date/Time: 2013/06/06 17:14:16 HERS Provider:. j Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/17/2013 •'Electronically Signed•at Ca10ERTS.com by Tammy Jenkins (Discovery Builders California) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611712013 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New ExistinR Altered Removed Volume Year Built HVAC 1 Maid Quarters 993 11,420 HVAC 2 Kitchen & Dining 1,455 16,733 HVAC 3 &'4 Living 2,547 36,167 HVAC 5 Master 1,390 16,680 HVAC 6 Guest 1 & 2 1,440 17,280 HVAC 7 Play Room Bowling 2,856 39,984 HVAC 8 Theater 882 - 12,348 HVAC 9 2nd Floor Z 949 33,914 I: Totals 14,512 0 0 0 HVAC SYSTEMS-`. .. . ;,System Name.: Qt '4 411111-leating Type ` . Min. Eff. Cooling Type Min. Eff. Thermostat Type _'Status' HVAC 1 1 W Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HV9C 2 1 j S ` lEHeat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback' New HVAC 3 & 4 w_" ,W .. 2 S;Oji Heat„P_ump ' , r9 50 NSPF1 S f t Heat?Pum ,.. 1a6 QaSEER; ,Setback_,... New' � � '�"� 9 50 HSPF S `Itt1r.4 6 Pum r" 16 Q,SEER: Setback ' �` HVAC:S,�,f ��,� 1 ,d,S IitHeat�Pum , New -::� HVAC;6 ” 1SphtHe `t`Pump ' �9 SOHSPF S htHeat'Pum X1,6{0 SEER, Setback " .,• ..New r _ p. _ __ate p } HVACDI$TRIBUTIONF r '.:< _. : >. ; ;" .: n �, >-� Duct..Location .. ` -R .Value Tested? Status S'stem Narne��"° ; ° Heatin ..�-�.,R.;. �-Coohn ........ HVAC 1 �..,,„,., Ducted {. Ducted Attic, Ceiling Ins, vented, 8.0 m New HVAC 2 � ;?e Ducted ._. Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Duciea 4z Ducted Attic, Ceiling Ins, vented 8.0 0 New HVAC 5 .Du;.Ducted Attic, CeilingIns, vented 8.0 m New HVAC 6 �Ducted_t Ducted Attic, Ceiling Ins, vented 8.01 INew WATER'HEATING SYSTEMS=' ..S stem Name Qty. Type. Distribution Rated Input (Btu h) Tank . Cap. al Energy Factor or -RE Standby Loss or Pilot Ext. Tank Insul. R - Value Status Bradford -White Corp. M-1- 3 Large Gas All Pipes Ins 85,000 100 0.80 .0.00% n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC-HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 a System Name Pipe Length Pipe Diameter Insul. Thick. Qty - HP Plenum Outside Buried. 13❑ EnefgyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Pae 13 of 14 Reg: 213-N0035232C-000000000-0000 Registration Date/Time:-2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc :Electronically Filed by Tim Scott and Authenticated at CalCERTS.com - 6/'17/2013- ''Electronically %1772013' .Electronically Signed at CalCERTS.com by TammyJenkins (Discovery Builders California) 6/17/2013 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ' ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611712013 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existin Altered Removed Volume Year Built Totals 14,512 0 0 .0 HVAC SYSTEMS - ,...�„S stem Name. " Q ;::k iHeatin Type Min. Eff. CoolingType Min. Eff. -Thermostat Type Status HVAC 7 1 'i1. Spiit Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 8 1 ff§ Iit:Heat Pump 10.00 HSPF S lit Heat Pump 18.0 SEER Setback New HVAC 9 _ :. .1.. ;SOI�t HeatjP.um =9 50,HSPF� S I t:HeafAPum ... ' 16:QgSEER ;SetbackW ;:. New KIP RE—IN :...:, : - amu. ....... t f .. -..; - Al r,": n, .',,� ..rd'. C �,�,sJh"«:'�A�i,3., .h?Si£: .u". .:%.:.:.` W'. ';°'.w"„a,:'.,... "r+m-°"�. ,-�a,�..::. ,#�.a;i 50 HVACDISTRIBUTION 10 S stem Narne"" „Heatin — a£ �*Coohn y__. _ Duct.Location... - '- ,.:R Value Tested? Status 'H,VAC 7 Ducted Ducted .. Attic, Ceiling Ins, vented • . 8.0 m New' HVAC Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC.9 :: i Ducted {.21 Ducted . Attic, Ceiling Ins, vented 8.0 ❑ New F . ❑ WATER HEATING SYSTEMS"** S stem Name Qty. Type Distribution Rated . Input Btuh Tank Cap. al Energy Standby Factor toss or or RE Pilot Ext.' Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length " (ft) o c a — System Name Pipe Length Pipe Diameter . Insul: Thick. QtyTHP Plenum Outside Buried ❑ EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-17710:25:56 ID: Pae 14 of 14 -Reg:•213-N0035232C-000000000-0000 Registration Date/Time: 2013/06/06 17:14:16 HERS Provider: CalCERTS, Inc -`0 BUILDING ENERGY ANALYSIS REPORT i""I"! uz-' JUL 0 32013 PROJECT: Lippman Res CITY OF LA QutNTA Lot 101 & 102 Baffin AveOMMUNTY DEVELOPMENT La Quinta, CA 92253 Project Designer: Giannetti Architecture & Interiors, Inc. 11-980 San Vicente BI Ste 101 L.A., CA 90049 (310) 820-1329 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 k .c (760) 200-4780 �& CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCT ON DAT 1 BY Job Number: 1'O ..GjgrCp Date: 6/10/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. 0 0 TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures'Summary 17 HVAC System Heating and Cooling Loads Summary 20 Room Load Summary 28 Room Heating Peak Loads 36 Room Cooling Peak Loads 44 EnergyPro 5.1 by EnergySoft Job Number. ID: User Number: 6712 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2013 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,512 Addition # of Stories FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Wall Wood Framed R-21 9,753 New Slab Unheated Slab -on -Grade None 11,563 Perim = 978' New Roof Wood Framed Attic R-38 11,563 Radiant Barrier New Door Opaque Door None 48 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Right (N) 1,687.0 0.390 0.28 none none Bug Screen New Front (E) 1,100.0 0.390 0.28 none none Bug Screen New Rear (149 330.0 0.390 0.28 30.0 none Bug Screen New Left (S) 440.0 0.390 0.28 none none Bug Screen New Rear (W 760.0 0.390 0.28 14.0 none Bug Screen New Rear (K9 416.0 0.390 0.28 none none Bug Screen New Front (E) 720.0 0.280 0.28 6.0 none Bug Screen New Left (S) 140.0 0.390 0.28 6.0 none Bug Screen New Rear (W) 600.0 0.390 0.28 6.0 none Bug Screen New Rear (149 220.0 0.390 0.28 10.0 none Bug Screen New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC I' Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 3 Large Gas 100 0.80 All Pipes Ins New Ene Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 3 of 53 • • 0 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2013 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,512 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 5 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 6 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 4 of 53 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2013 Project Address Lot 101 & 102 Baffin Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 14,512 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type CavityFeatures see Part 2 of 5 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAO DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC 8 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New HVAC 9 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnerqyPro 5.1 bEnergySoft user Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 5 of 53 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the s ecial 'ustification and documentation submitted. The DHW System Bradford -White Corp. M-I-100T6BN is a non-NAECA large storage gas water heater. Verify DHW details. The HVAC System HVAC'1 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential A endix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 98.0 ft2 Covered Slab Floor, 3.500" thick at Maid Quarters HIGH MASS Design - Verify Thermal Mass: 895.0 ft2 Exposed Slab Floor, 3.500" thick at Maid Quarters The HVAC System HVAC 2 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a se arate thermostat. In addition the air flow requirements and fan watt draw re uirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 280.0 ft2 Covered Slab Floor, 3.500" thick at Kitchen & Dining HIGH MASS Design - Verify Thermal Mass: 1,175.0 ft2 Exposed Slab Floor, 3.500" thick at Kitchen & Dining The HVAC System HVAC 3 & 4 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,547.0 ft2 Exposed Slab Floor, 3.500" thick at Living The HVAC System HVAC 5 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 994.0 ft2 Covered Slab Floor, 3.500" thick at Master HIGH MASS Design - Verify Thermal Mass: 396.0 ft2 Exposed Slab Floor, 3.500" thick at Master The HVAC System HVAC 6 must serve only Sleeping Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The Cooling System Carrier 25HNB924/FE4AN8003 includes credit for a 13.5 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 1 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 1 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNS960/FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 2 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 2 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 2 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 2 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 3 & 4 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. Ene Pro 5.1 b Ene Soft User Number.- 6712 RunCode: 2013-06-10717:53:58 ID: Page 6 of 53 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HIGH MASS Design - Verify Thermal Mass: 990.0 ft2 Covered Slab Floor, 3.500" thick at Guest 1 & 2 HIGH MASS Design - Verify Thermal Mass: 450.0 ft2 Exposed Slab Floor, 3.500" thick at Guest 1 & 2 The HVAC System HVAC 7 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 2,570.0 ft2 Covered Slab Floor, 3.500" thick at Play Room Bowling HIGH MASS Design - Verify Thermal Mass: 286.0 112 Exposed Slab Floor, 3.500" thick at Play Room Bowling The HVAC System HVAC 8 must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must have a separate thermostat. In addition the air Now re uirements and fan waft draw requirements in Residential Appendix RA3.3 must be met. HIGH MASS Design - Verify Thermal Mass: 882.0 ft2 Covered Slab Floor, 3.500" thick at Theater The Roof R-38 Roof(R.38.2x 14.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 3 & 4 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 3 & 4 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 3 & 4 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 5 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 5 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 5 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 5 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 6 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 6 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 6 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. hn-emvPro 5.1 by EneMySoft User Number., 6712 RunCode: 2013-06-10717:53:58 ID: Pae 7 of 53 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5CF-1 R Project Name Lippman Res Building Type ®Single Family ❑Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 6 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 7 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 7 incorporates HERS Verified Rehigerant Charge'or a Charge Indicator Display. The HVAC System NVAC 7 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 7 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9241FE4ANB003 includes credit for a 13.5 EER Condenser A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System HVAC 8 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 8 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 8 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 8 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. The Cooling System Carrier 25HNB9601FE4ANB006 includes credit for a 12.5 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. Erie Pro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 8 of 53 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. The HVAC System HVAC 9 includes credit for Verified Fan Energy. Measured Fan Energy may not exceed 0.58 w/cfm. The HVAC System HVAC 9 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System HVAC 9 includes credit for verified adequate airflow. A certified HERS rater must diagnostically measure airflow of the HVAC System. The HVAC System HVAC 9 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. Ene Pro 5.1 6 Ene Soft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 9 of 53 0 • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Lippman Res 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 6/10/2013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.95 4.86 -0.91 Space Cooling 52.77 46.56 6.21 ' Fans 10.16 11.86 -1.71 Domestic Hot Water 2.51 1.69 0.82 Pumps 0.00 0.00 0.00 Totals 69.38 64.97 4.41 Percent Better Than Standard: 6.4% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 5,393 1,820 Fuel Available at Site: Natural Gas (S) 21709 560 Raised Floor Area: 0 (W 5,415 2,326 Slab on Grade Area: 11,563 (N) 2,697 1,687 Average Ceiling Height: 12.7 Roof 11,563 0 Fenestration Average U -Factor: 0.38 TOTAL: 6,413 Average SHGC: 0.28 Fenestration/CFA Ratio: 44.2 % REMARKS The Madison Club Country Club Lots 101 & 102 STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc, 6/10/2013 d� Address 77-085 Michigan Drive Name Tim Scott Citv/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Giannetti Architecture & Interiors, Inc. Address 11-980 San Vicente BI Ste 101 Name Giannetti Architecture & Interiors City/State/Zip L.A., CA 90049 Phone (310) 820-1329 Signed License # Date Erie Pro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-06-10717:53:58 /D: Pae 10 of 53 • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 OPAQUE SURFACE DETAILS Surface T e Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wail 90 0.069 R-21 0 90 New 4.3.1-A6 Maid Quarters Wall 158 0.069 R-21 90 90 New 4.3.1-A6 Maid Quarters Wall 436 0.069 R-21 180 90 New 4.3.1-A6 Maid Quarters Wall 329 0.069 R-21 270 90 New 4.3.1-A6 Maid Quarters Slab 98 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Slab 895 0.730 None 0 180 New 4.4.7-A1 Maid Quarters Roof 154 0026 R-38 270 0 New 4.2.1-A9 Kitchen & Dining Wail 273 0.069 R-21 90 90 New 4.3.1-A6 Kitchen & Dining Wall 183 0.069 R-21 180 90 New 4.3.1-A6 Kitchen & Dining Door 24 0.500 None 180 90 New 4.5.1-A4 Kitchen & Din in Wall 78 0.069 R-21 270 90 New 4.3.1-A6 Kitchen & Dining Slab 280 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Slab 1,175 0.730 None 0 180 New 4.4.7-A1 Kitchen & Dining Roof 2,547 0.026 R-38 270 0 New 4.2.1-A9 Living Wall 10 0.069 R-21 0 90 New 14.3.1-A6 Livin Wall 424 0.069 R-21 901 90 New 14.3.1-A6 ILiving FENESTRATION SURFACE DETAILS ID Tvpe Area U -Factor SHGCz Azm Status Glazing Type Location/Comments 1 Window 25.0 0.390 1 NFRC 0.28 1 NFRC 0 New Double Non -Metal Tinted Maid Quarters 2 Window 48.0 0.390 1 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 3 Window 72.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 4 Window 40.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Maid Quarters 5 Window 6.0 0.390 NFRC 0.28 NFRC W New Double Non -Metal Tinted Maid Quarters 6 Window 30.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Kitchen & Dining 7 Window 24.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Kitchen & Dining 8 Window 330.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Kitchen & Dining 9 Window 162.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Living 10 Window 162.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Living 11 Window 140.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Living 12 Window 140.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 13 Window 80.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 14 Window 140.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted Living 15 Window 360.0 0.390 NFRC 0.28 NFRC 90 New I Double Non -Metal Tinted Living 16 Window 140.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len Hc3t LExt RExt Dist Len I Ri ht Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 10.01 33.0 30.0 0.1 30.0 30.0 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 [Bug Screen 0.76 16 19ug Screen 1 0.76 �_Sn_emyPro 5.1 by Ene Soft User Number., 6712 RunCode: 2013-06-10717:53:58 ID: Pae 11 of 53 • • 0 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 OPAQUE SURFACE DETAILS Surface Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments -Type Wall 56 0.069 R-21 180 90 New 4.3.1-A6 Living Wall 164 0.069 R-21 270 90 New 4.3.1-A6 Living Slab 2,547 0.730 None 0 180 New 4.4.7-A1 Living Roof 635 0.026 R-38 270 0 New 4.2.1-A9 Master Wall 122 0.069 R-21 0 90 New 4.3.1-A6 Master Wall 456 0.069 R-21 90 90 New 4.3.1-A6 Master Wall 260 0.069 R-21 270 90 New 4.3.1-A6 Master Slab 994 0.730 None 0 180 New 4.4.7-A1 Master Slab 396 0.730 None 0 180 New 4.4.7-A1 Master Roof 1,440 0.026 R-38 270 0 New 4.2.1-A9 Guest 1 & 2 Wall 156 0.069 R-21 0 90 New 4.3.1-A6 Guest 1 & 2 Wall 3841 0.069 R-21 90 90 New 4.3.1-A6 Guest 1 & 2 Wall 416 0.069 R-21 180 90 New 4.3.1-A6 Guest 1 & 2 Wall 384 0.069 R-21 270 90 New 4.3.1-A6 Guest 1 & 2 Slab 990 0.730 None 0 180 New 4.4.7-A1 Guest 1 & 2 Slab 450 0.730 None 0 180 New 4.4.7-A1 IGuest 1 & 2 FENESTRATION SURFACE DETAILS ID Type I Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 400.0P0.3901NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Living 18 Window 360.0 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Living 19 Window 40.0 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Master 20 Window 40.0 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Master 21 Window 140.0 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Master 22 Window 270.0 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Master 23 Window 56.0 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Master 24 Window 90.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Master 25 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Guest 1 & 2 26 Window 280.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Guest 1 & 2 27 Window 40.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Guest 1 & 2 28 Window 100.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted Guest 1 & 2 29 Window 140.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Play Room Bowling 30 Window 280.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Play Room Bowling 31 Window 168.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted Play Room Bowling 32 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint I Play Room Bowling (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hanq Left Fin Len I H t LExt REM Dist Len Ri ht Fin Hat Dist Len H t 17 Bug Screen 0.76 10.0 40.0 14.01 0.1 14.0 14.0 18 Bug Screen 0.76 10.0 36.0 14.0 0.1 14.0 14.0 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.761 1 32 JBug Screen 0.761 10.01 6.0 6.0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Pae 12 of 53 • • C7 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Lippman Res Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Roof 2,956 0.026 R-38 270 0 New 4.2.1-A9 Play Room Bowling Wall 28 0.069 R-21 0 90 1 New 4.3.1-A6 Play Room Bowling Wall 860 0.069 R-21 90 90 1 New 4.3.1-A6 Play Room Bowling Door 241 0.500 None 90 90 New 14.5.1-A4 Play Room Bowling Wall 490 0.069 1 R-21 180 90 New 4.3.1-A6 Play Room Bowling Wall 1,710 0.069 1 R-21 270 90 New 4.3.1-A6 Play Room Bowling Slab 2,570 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Slab 286 0.730 None 0 180 New 4.4.7-A1 Play Room Bowling Roof 882 0.026 R-38 270 0 New 4.2.1-A9 Theater Wall 324 0.069 R-21 0 90 1 New 4.3.1-A6 Theater Wall 324 0.069 R-21 90 90 New 4.3.1-A6 Theater Wall 324 0.069 R-21 180 90 1 New 4.3.1-A6 Theater Slab 882 0.730 None 0 180 New 4.4.7-A1 Theater Roof 2,949 0.026 R-38 270 0 New 4.2.1-A9 2nd Floor Wall 280 0.069 R-21 0 90 New 4.3.1-A6 2nd Floor Wall 670.-0.069 R-21 90 90 New 14.3.1-A6 2nd Floor FENESTRATION SURFACE DETAILS ID TyDe Area U -Factor SHGC Azm Status Glazing Type Location/Comments 33 Window 180.0 0.280 1 NFRC 0.28 1 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 34 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 35 Window 180.0 0.280 NFRC 0.28 NFRC 90 New Dual Non -Metal Tint Play Room Bowling 36 Window . 140.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted Play Room Bowling 37 Window 180.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted Play Room Bowling 38 Window 30.0 0.390 NFRC 0.28 NFRC 0 New Double Non -Metal Tinted 2nd Floor 39 Window 130.0 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted 2nd Floor 40 Window 30.01 0.390 NFRC 0.28 NFRC 90 New Double Non -Metal Tinted 2nd Floor 41 Window 30.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted 2nd Floor 42 Window 100.0 0.390 1 NFRC 0.28 NFRC 180 New I Double Non -Metal Tinted 2nd Floor 43 Window 70.0 0.390 NFRC 0.28 NFRC 180 New Double Non -Metal Tinted 2nd Floor 44 Window 220.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 45 Window 140.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 46 Window 140.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor 47 Window 140.0 0.390 NFRC 0.28 NFRC 270 New Double Non -Metal Tinted 2nd Floor (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hot Wd Ove anq Left Fin Len I H t LExt RExt Dist Len Ri ht Fin H t Dist Len H t 33 Bug Screen 0.76 10.0 18.0 6.01 0.1 6.01 6.0 34 Bug Screen 0.76 10.0 18.0 6.01 0.1 6.01 6.0 35 Bug Screen 0.76 10.0 18.0 6.01 0.1 6.01 6.0 36 Bug Screen 0.76 10.0 14.0 6.01 0.1 6.01 6.0 37 Bug Screen 0.76 10.0 18.0 6.0 0.1 6.01 6.0 38 Bug Screen 0.76 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 10.0 22.0 10.01 0.1 10.0 10.0 45 Bug Screen 0.76 10.0 L 14.0 6.0 0.1 6.0 6.0 46 Bug Screen 0.76 10.01 14.0 6.0 0.1 6.0 6.0 47 Bug Screen 0.76 10.01 14.0 6.0 0.1 6.0 6.0 Ene Pro 5.1 6 Ene Soft User Number. 6712 RunCode: 2013-06-10717:53:58 ID: Pae 13 of 53 • • 0 • • 1 1 I I • Project. Pes . Type PI Single Family 0 Multi Family ■ Addition Alone 0 Existing+ Addition/Alteration OPAQUELippman Joint Appendix 4 Location/Comments -FENESTRATION�RWEIRMI IMM.... . . ... . -. EXTERIOR SHADING DETAILS _ • • 0 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVAC 1 Maid Quarters 993 11,420 HVAC 2 Kitchen & Dining 1,455 16,733 HVAC 3 & 4 Living 2,547 36,167 HVAC 5 Master 1,390 16,680 HVAC 6 Guest 1 & 2 1,440 17,280 HVAC 7 Play Room Bowling 2,856 39,984 HVAC 8 Theater 882 12,348 HVAC 9 2nd Floor 2,949 33,914 Totals 14,5121 0 0 0 HVAC SYSTEMS System Name Oty. Heating Type. Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 1 1 Split Heat Pump 10.00 HSPFI Split Heat Pump 18.0 SEER I Setback New HVAC 2 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 3 & 4 2 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 5 1 Split Heat Pump 9.50 HSPF Split Heat PuTp 16.0 SEER Setback New HVAC 6 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION S stem Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 2 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 3 & 4 Ducted Ducted Attic, Ceiling Ins, vented 8.0 d New HVAC 5 Ducted I Ducted Attic, Ceiling Ins, vented 8.0 El New HVAC 6 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Bradford -Mite Corp. M-1- 3 Large Gas All Pipes Ins 85,000 100 0.80 0.00% Ma New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft o Q System Name Pipe Length Pipe Diameter Insul. Thick. Oty. HP Plenum Outside Buried ❑ EnerqyPro 5.1 bv EnerovSoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Pae 15 of 53 • :7 0 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Lippman Res Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1611012013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built Totals 14,512 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC 7 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC 8 1 Split Heat Pump 10.00 HSPF Split Heat Pump 18.0 SEER Setback New HVAC 9 1 Split Heat Pump 9.50 HSPF Split Heat Pump 16.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC 7 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 8 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New HVAC 9 Ducted Ducted Attic, Ceiling Ins, vented 8.0 M New WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length (ft) o U) Q System Name Pipe Length Pipe Diameter. Insul. Thick. O FHP Plenum Outside Buried ❑ Ene Pro 5.1 b Ene Soft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Pae 16 of 53 4 MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3 MF -1 R Project Name Date Lippman Res 6/10/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: f 116 a 1: Doors and windows between conditioned and unconditioned s aces are manufactured to limit air leakage. v C1 i C/n\A • CnnnMrotinn :,rr,rf„nr� 1--t finirf-fahriratarf w,nrfnwel haus a Iahal Iietinn tha rartifiarf I I-Fartnr rartifiad Rnlar Heat Gain Coefficient(SHGC) and infiltration that meets the requirements of §10-111(a). §117• Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. §118�a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §l18(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. 'i. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 4150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. 110(c): Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. §150(f): Air retarding wrap is tested labeled 'and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form. -§150(q): Mandatory Vapor barrier installed in Climate Zones 14 or 16. J..§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance • rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. ,J 'Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150(e)1A• Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. �J; §150(e)113' Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square Inches in area and is ��': equipped with a with a readily accessible operable and tight -fitting damper and or a combustion -air control device. ,§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the =outside of the building are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy :.Commission. §113(6)5 Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release •.valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and "spa heaters ff'§150(h) Heating and/or cooling loads are calculated in accordance with ASHRAE SMACNA or ACCA. -; 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(6). J §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water ,;.'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the ....-tank. �' §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatina sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(')3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. .9;1§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in . Fconditioned space 'N150(114: Sblar water-heatinq systems and/or collectors are certified by the Solar Rating and Certification Corporation. ."'. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 17 of 53 • J L MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Lippman Res 1611012013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area -of the ducts. . §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and not use electric resistance heating ora pilot light. ,shall §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. .§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. -§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of -illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 18 of 53 0 a MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Lippman Res 1611012013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms }''shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 4150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. -§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more -dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that -they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management •control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable ( requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. T. EnergyPro 5.1 by EnergySoff User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 19 of 53 C. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date "Lippman Res 6/10/2013 System Name Floor Area HVAC 1 993 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 488 10,769 Return Vented Lighting 0 Return Air Ducts 622 Return Fan 0 Ventilation o 0 Supply Fan 0 Supply Air Ducts 622 TOTAL SYSTEM LOAD 1 12,012 PEAK COIL HTG. PEAK Heating S tem Latent CFM Sensible Output perSystem 25,400 1,469 690 12,843 Total Output Btuh 25,400 Outgut (Btuh/sqftl 25.6 491 Cooling System 0 Output perSystem 24,800 01 0 0 Total Output Btuh 24,800 1,469 0 Total Output ons 2.1 491 . Total Output Btuh/s ft 25.0 Total Output (sqft/Ton 480.5 1 13,825 -Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Alrflow cfm 800 Carrier 25HNB924/FE4ANB0o3 18,893 690 15,864 Airflow cfm/s ft 0.81 Airflow cfm/Ton 387.1 Total Adjusted System Output 1 18,893 (Adjusted for Peak Design conditions) 690 15,864 Outside Air % 0.0% 0.00 Outside Air cfm/s ft I TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 71 OF 90 OF 90 OF /-� Outside Air 0 cfm . Heating Coil Supply Fan 89 OF 800 cfm ROOM 71 OF 72 OF SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak -COOLING 112 / 78 OF 71 / 58 OF 49148 OF 49 / 48 OF Outside Air Supply Fan 49148 °F 0 cfm Cooling Coil .......... .._.. 800 cfm ..-.............. . ................ 45.3% ROOM 70/57°F 71/57°F .4 :01 I — J .4 1 EnergyPro 5.1 by EnergySoR User Number. 6712 RunCode: 2013-06-10T17:53:58 ID: Page 20 of 53 C .['HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date ;Lippman Res 6/10/2013 System Name Floor Area HVAC 2 1,455 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 777 13,104 Return Vented Lighting 0 Return Air Ducts 757 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 757 TOTAL SYSTEM LOAD 14,617 COIL HTG. Latent CFM 2,060 893 0 0 2,060 PEAK Heating System Sensible Output per System 58,500 15,779 Total Output Btuh 58,500 Output Btuh/s ft 40.2 603 -Cooling System 0 Output per Ss tem 55,500 0 Total Output Stuh 55,500 0 Total Output ons 4.6 603 Total Output Btuh/s ft 38.1 Total Output s ft/Ton 314.6 16,986 -Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Alrflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,244 10,151 36,538 1 36,538 Airflow cfm/s ft 1.37 Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 35,244 (Adjusted for Peak Design conditions) 10,151 0.00 Outside Air cfm/s ft TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM -Note: values above given at ARI conditions :-HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 72 OF 89 OF 89 OF Outside Air 0 cfm Heating Coil Supply Fan 89 OF 2,000 cfm ROOM 72 OF 72 OF 'COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 °F 70160 OF 54 / 53 OF 54 ! 53 OF Outside Air 0 cfm Cooling Coil Supply Fan 54153 OF ..... 2,000 cfm 54.6% ROOM 70 / 60 OF _- 70/ 60 OF L. EnerovPro 5.1 by EnemvSoR User Number. 6712 RunCode: 2013-06-10717:53:58 ID: Page 21 of 53 ".HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res System Name HVAC 3 & 4 ENGINEERING CHECKS SYSTEM LOAD Number of Svstems 2 COIL COOLING PEAK Total Total Outpu Total Outpu Total Outpu Total Outpu Air System CFM per Sy Airflow (cfn Airflow (cin Airflow (cfn Outside Air Outside Air Note: values abi HEATING SYS 26 OF Outside Air 0 cfm 72 OF 4 :COOLING SN 112 / 78 OF — 0A Outside Air 0 cfm 71 / 60 OF EnergyPro 5.1 CFM Sensible Lat 3,793 61,106 0 3,528 0 0 0 0 3,528 68,161 71,4921 19 6/10/2013 Floor Area 2,547 COIL HTG. PEAK CFM Sensible 5 3,068 52,941 2,024 0 0 0 0 0 2,024 55 56,989 71,4921 19,593 Auo 3 PM 73,075 73,075 Jan 1 AM 72 OF 89 OF /-� 89 OF Heating Coil Supply Fan 88 OF 4,000 cfm ROOM 72 OF IMETICS (Airstream Temperatures at Time of Cooling Peak) 71 /60°F 54/53°F 54/53°F ME 0' Cooling Coil Supply Fan 55 / 54 °F 4,000 cfm_.._.__.... .................................. 54.8% ROOM 70160 OF 4 0.. 1 *. I 11 4 User Number: 6712 RunCode: 2013-06-fOT17:53:58 ID: 22 of 53 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 58,500 117,000 45.9 55,500 111,000 9.3 it 43.6 i 275.4 2,000 HVAC EQUIPMENT SELECTION 4,000 Carrier 25HNB960/FE4ANB006 1.57 432.4 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 0.00 at ARI conditions (CHROMETRICS (Airstream Temaeratures at Time CFM Sensible Lat 3,793 61,106 0 3,528 0 0 0 0 3,528 68,161 71,4921 19 6/10/2013 Floor Area 2,547 COIL HTG. PEAK CFM Sensible 5 3,068 52,941 2,024 0 0 0 0 0 2,024 55 56,989 71,4921 19,593 Auo 3 PM 73,075 73,075 Jan 1 AM 72 OF 89 OF /-� 89 OF Heating Coil Supply Fan 88 OF 4,000 cfm ROOM 72 OF IMETICS (Airstream Temperatures at Time of Cooling Peak) 71 /60°F 54/53°F 54/53°F ME 0' Cooling Coil Supply Fan 55 / 54 °F 4,000 cfm_.._.__.... .................................. 54.8% ROOM 70160 OF 4 0.. 1 *. I 11 4 User Number: 6712 RunCode: 2013-06-fOT17:53:58 ID: 22 of 53 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 6/10/2013 System Name HVAC 5 Floor Area 1,390 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,510 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,500 24,642 1,976 1,294 22,530 Total Output Btuh 58,500 0 Output Btuh/s ft 42.1 1,423 861 Cooling System 0 0 Output perSystem 55,500 0 0 0 0 Total Output Btuh 55,500 0 1,976 0 Total Output ons 4.6 1,423 861 Total Output Btuh/s ft 39.9 Total Output s ft/Ton 300.5 27,488 Eii�i Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,476 10,053 36,538 Airflow dfm/s ft 1.44 Total Adjusted System Output 35,476 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,053 36,538 Aug 3 PM Jan 1 AM Airtlovii cfm/Ton 432.4 Outside r % 0.0% Ai Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF f4 Heating Coil Supply Fan 88 OF 2,000 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air Ar 0 cfm 71 ! 60 OF 71 160 OF 54 / 53 OF 54 / 53 OF Cooling Coil Supply Fan 55 / 53 °F 2,000 cfm........................... ................. _. . 54.9% ROOM 70 / 60 OF � r EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 23 of 53 r: • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 6/10/2013 System Name HVAC 6 Floor Area 1,440 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,003 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 58,500 16,737 2,040 1,288 22,428 Total Output Btuh 58,500 0 Output Btuh/s ft 40.6 966 857 Cooling System 0 0 Output perSystem 55,500 0 0 0 0 Total Output Btuh 55,500 0 27040 0 Total Output ons 4.6 966 857 Total Output Btuh/s ft 38.5 Total Output s ft/Ton 311.4 18,669 24,143 "Air System CFM perSystem 2.000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 35,312 10,127 36,538 Alrf low cfm/s ft 1.39 Total Adjusted System Output 35,312 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,127 36,538 Aug 3 PM Jan 1 AM Airflow cfm/Ton 432.4 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 89 OF 89 OF Heating Coil Supply Fan 88 OF 2,000 cfm ROOM 72 °F COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air Ar 0 cfm 70/60°F 70 / 60 OF 54 / 53 OF 54153 OF Cooling Coil Supply Fan 54 / 53 OF 2,000 cfm_.................. .... ._................_._.. 54.7% ROOM 70!60°F r EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2013-06-10717:53:58 ID: Page 24 of 53 17 - HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 6/10/2013 System Name HVAC 7 Floor Area 2,856 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 3,829 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 58,500 54,197 3,850 3,633 58,275 Total Output Btuh 58,500 0 Output Btuh/s ft 20.5 3,129 2,228 Cooling System 0 0 Output per System 55,500 0 0 0 0 Total Output Btuh 55,500 0 3,850 0 Total Output ons 4.6 3,129 2,228 Total Output Btuh/s ft 19.4 Total Output s ft/Ton 617.5 60,454 62,730 ''Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier25HNB960/FE4ANB006 34,564 11,879 36,538 Airflow cfm/s ft 0.70 36,538 I Jan 1 AM Airflow cfm/Ton 432.4 Outside Air % 0.0% Total Adjusted System Output 1 34,564 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 11,879 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air. 0 cfm 71 OF 71 OF 88 OF 88 OF 1 i Heating Coil Supply Fan 87 OF 2,000 cfm LOOM 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside -Air 0 cfm 71 / 61 OF 71 /61 OF 55/54°F 55/54°F Cooling Coil Supply Fan 57 ! 55 OF 2,000 cfm 58.9 °i° ROOM 70/ 61 OF fl EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 25 of 53 • • HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 6/10/2013 System Name HVAC 8 Floor Area 882 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 287 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 25,400 6,539 1,327 483 9,147 Total Output Btuh 25,400 0 Output Btuh/s ft 28.8 378 350 Cooling System 0 0 Output perSystem 24,800 0 0 0 0 Total Output Btuh 24,800 0 378 7,294 1,327 0 Total output ons 2.1 350 Total Output Btuh/s ft 28.1 Total Output s ft/Ton 426.8 9,846 "Air System CFM perSystem 800 HVAC EQUIPMENT SELECTION Airflow cfm 800 Carrier 25HNB924/FE4ANB003 18,971 510 15,864 Airflow cfm/s ft 0.91 Total Adjusted System Output 18,971 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 510 15,864 Aug 3 PM Jan 1 AM Airflow cfm/Ton 387.1 Outside Air°/, 0.0% Outside Air cfm/s ft 0.00 ',',Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 72 OF 72 OF 90 OF ^ 90 OF (� Heating Coil Supply Fan 90 OF 800 cfm ROOM I, g 72 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF Outside Air 0 cfm 70 / 57 OF 70157 OF 48 / 47 OF 48 / 47 OF � O Cooling Coil Supply Fan 49 ! 47 OF 800 cfm............. ._......_.............. ........ 44.4% ROOM 70/ 57 OF EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-IOT17:53:58 ID: Page 26 of 53 4 :HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Lippman Res Date 6/10/2013 System Name HVAC 9 Floor Area 2,949 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 7 1 COIL COOLING PEAK CFM Sensible I Total Room Loads 2,687 39,849 Return Vented Lighting 0 Return Air Ducts 2,300 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,300 TOTAL SYSTEM LOAD 44,449 COIL HTG. Latent CFM 3,969 1,992 0 0 3,969 PEAK Heating S tem Sensible Output per System 58,500 33,823 Total Output Btuh 58,500 Output Btuh/s ft 19.8 1,293 -.Cooling System 0 Output per S tem 55,500 0 Total Output Btuh 55,500 0 Total Output ons 4.6 1,293 Total Output Btuh/s ft 18.8 Total Output s ft/Ton 637.6 36,409 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 25HNB960/FE4ANB006 34,257 Total Adjusted System Output 34,257 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 12,020 36,538 12,020 36,538 Aug 3 PM Jan 1 AM Airflow cfm/s ft 0.68 Airflow cfm/Ton 432.4 Out Air % 0.0% Outside Air cfm/s ft 0.00 eNote: values above given at ARI conditions .-HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 0 cfm 71 OF 71 OF 89 OF 89 OF V Heating Coil Supply Fan 88F 2,000 cfm ROOM 72 OF SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak .,COOLING 112/78°F Outside Air 0 cfm Ar 71/61°F I 71 /61 OF 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 55 °F 2,000 cfm _._......_.......___.... 58.5% ROOM 70/61°F Energ t 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 27 of 53 • • ROOM LOAD SUMMARY Project Name Date Lippman Res 6/10/2013 System Name Floor Area HVAC 1 993 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible Latent CFM Sensible I Latent CFM Sensible Maid Quarters Maid Quarters 1 488 10,769 1,469 488 10,769 1,469 690 128143 . Total includes ventilation load for EnerovPro 5.1 by EnergySoR U PAGE TOTAL TOTAL' 488 10,7691 1,4691 690 12843 488 10,769 1,469 690 1ZB43 • 0 ROOM LOAD SUMMARY Project ..man Res Date 611i i Name HVAC 2 FloorSySt6M 1,455 ROOM LOAD _ -•• •• -M Fog MOT09- • - Kitchen & Dining Kitchen & Dining . ®� ,.I �� • is C] ROOM LOAD SUMMARY Project Name Date Lippman Res 6/10/2013 System Name Floor Area HVAC 3 & 4 2,547 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM Sensible Living Living 1 1 3,793 61,106 3,455 3,793 61,106 3,455 3,068 52,941 0 PAGE TOTAL TOTAL* 3,793 61,106 3,455 3,068 52,941 3,7931 ' 61,106 3,4551 3,0681 52,941 * Total includes ventilation load for zonal systems. EnemvPro 5 1 by EneravSoR User Number 6712 RunCode: 2013-06-10717:53:58 ID: Page 30 of 53 • L' • • • • ROOM LOAD SUMMARY Project Name Date Lippman Res 6/10/2013 System Name Floor Area HVAC 6 1,440 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible Guest 1 & 2 Guest 1 & 2 1 1 1 1,0031 16,7371 2,040 1,003 16,737 2,040 1,288 22,428 PAGE TOTAL TOTAL* 1,003 16,737 2,040 1,288 22,428 1,003 16,737 2,040 1,288 22,428 * Total includes ventilation load for zonal systems. EnergvPro 5.1 by Ene Soft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 32 of 53 s • • • 11 ROOM LOAD SUMMARY Project Name Date Lippman Res 6/10/2013 System Name Floor Area HVAC 9 2,949 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFMSensible I Latent CFM I Sensible 2nd Floor 2nd Floor 1 1 2,6871 39,8491 3, 969 2, 687 39,8491 3, 969 1,9921 33,823 PAGE TOTAL TOTAL' Z687 39,8491 3,9691 1,9921 33,823 2,6871 39,8491 3,9691 1,9921 33,823 ' Total includes ventilation load for zonal systems. Ene Pro 5 1 6 Ene Soft User Number, 6712 RunCode• 2013-06-10717:53:58 ID: Page 35 of 53 • • • ROOM HEATING PEAK LOADS Project Name Lippman Res Date 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area. Indoor Dry Bulb Temperature Maid Quarters 993.0 ft' 72 OF, Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area R-21 Wall (W.21.2x6.16) 1,013.0 X Double Non -Metal Tinted 191.0 X Slab -On -Grade perim = 108.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 993 X Schedule Air Sensible Area Ceiling Fraction U -Value 0.0690 X 0.3900 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X another room 11.50 X 0.276 Height ACH AT °F 46 = 46 = 46 = = = = = = = = = = = = = = = = = = = = = = = = = = = = Page Total /60] X 46 AT Btu/hr 3,215 3,427 3,627 10,268 = 2,575 TOTAL HOURLY HEAT LOSS FOR ROOM 12,843 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 36 of 53 • • • ROOM HEATING PEAK LOADS Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Dining Time of Peak Jan 1 AM Floor Area 1,455.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT °F Btu/hr R-38 Roof(R. 38.2x 14.16) 154.0 X 0.0260 X 46 = 184 R-21 Wall (W.21.2x6.16) 534.0 X 0.0690 X 46 = 1,695 Double Non -Metal Tinted 384.0 X 0.3900 X 46 = 6,889 Wood Door 24.0 X 0.5000 X 46 = 552 Slab -On -Grade perim = 80.0 X 0.7300 X 46 = 2,686 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 12,006 Infiltration:[ 1.00 X 1.064 X 1,455 X 11.50 X 0.276 /60] X 46 = 3,773 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,779 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 37 of 53 • • • ROOM HEATING PEAK LOADS Project NameDate Lippman Res 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Time of Peak Jan 1 AM Floor Area 2,547.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF, Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x14.16) 2,547.0 X 0.0260 X 46 = 3,046 R-21 Wall (W.21.2x6.16) 654.0 X 0.0690 X 46 = 2,076 Double Non -Metal Tinted 2,084.0 X 0.3900 X 46 = 37,387 Slab -On -Grade perim = 114.0 X 0.7300 X 46 = 3,828 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 46,337 Infiltration:[ 1.00 X 1.064 X 2,547 )( 14.20 X 0.224 /60] X 46 = 6,604 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 52,941 EnergyPro 5.1 by Energ Soft User Number.' 6712 RunCode: 2013-06-10717:53:58 ID: Page 38 of 53 C] • • ROOM HEATING PEAK LOADS Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Time of Peak Jan 1 AM Floor Area 1,390.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF, Conduction Area U -Value AT °F Btu/hr R-38 Roof(R. 38.2x 14.16) 635.0 X 0.0260 X 46 = 759 R-21 Wall (W.21.2x6.16) 838.0 X 0.0690 X 46 = 2,660 Double Non -Metal Tinted 636.0 X 0.3900 X 46 = 11,410 Slab -On -Grade perim = 122.0 X 0.7300 X 46 = 4,097 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X - X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 1 18,926 Infiltration:[ 1.00 X 1.064 X 1,390 X 12.00 X 0.265 /60] X 46 = 3,604 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,530 EnergyPro 5.1 by Energ Soft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 39 of 53 • • • ROOM HEATING PEAK LOADS Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Time of Peak Jan 1 AM Floor Area 1,440.0 ft2 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT °F Btu/hr R-38 Roof(R.38.2x14.16) 1,440.0 X 0.0260 X 46 = 1,722 R-21 Wall (W.21.2x6.16) 1,340.0 X 0.0690 X 46 = 4,253 Double Non -Metal Tinted 460.0 X 0.3900 X 46 = 8,252 Slab -On -Grade perim = 133.0 X 0.7300 X 46 = 4,466 X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 18,694 Infiltration:[ 1.00 X 1.064 X 1,440 X 12.00 X 0.265 /601 X 46 = 3,734 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 2Z428 Energ Pro 5.1 by Energ Soft User Number. 6712 RunCode: 2013-06-10717:53:58 ID: Page 40 of 53 • • • ROOM HEATING PEAK LOADS Project Name Lippman Res Date 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Play Room Bowling Floor Area 2,856.0 ft' Indoor Dry Bulb Temperature 72 OF Time of Peak Outdoor Dry Bulb Temperature Jan 1 AM 26 OF Conduction Area U -Value R-38 Roof(R.38.2x14.16) 2,956.0 X 0.0260 X R-21 Wall (W.21.2x6.16) 3,088.0 X 0.0690 X Double Non -Metal Tinted 908.0 X 0.3900 X Wood Door 24.0 X 0.5000 X Dual Non -Metal Tint 720.0 X 0.2800 X Slab -On -Grade perim = 340.0 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to another room Infiltration:[ 1.00 X 1.064 X 2,856 X 14.00 X 0.227 Schedule Air Sensible Area Ceiling Height ACH Fraction AT *F 46 46 46 46 46 46 Page Total /60] X AT = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr 3,535 9,801 16,290 552 9,274 11,417 50,869 = 7,406 TOTAL HOURLY HEAT LOSS FOR ROOM 58,275 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 41 of 53 • • • ROOM HEATING PEAK LOADS Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Theater Time of Peak Jan 1 AM Floor Area 882.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF, Conduction Area U -Value OT OF Btu/hr R-38 Roof(R.38.2x14.16) X 0.0260 X 46 = 1,055 R-21 Wall (W.21.2x6.16) X 0.0690 X 46 = 3,085 Slab -On -Grade d72. perim X 0.7300 X 46 = 2,720 X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 6,860 Infiltration:[ 1.00 X 1.064 X 882 X 14.00 X 0.227 /60] X 46 = 2,287 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,147 rEn�e�yPro by Energ Sof User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 42 of 53 • 0 0 ROOM HEATING PEAK LOADS Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Time of Peak Jan 1 AM Floor Area 2,949.0 ft' Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 72 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof(R.38.2x 14.16) 2, 949.0 X 0.0260 X 46 = 3,527 R-21 Wall (W.21.2x6.16) 1,314.0 X 0.0690 X 46 = 4,171 Double Non -Metal Tinted 1,030.0 X 0.3900 X 46 = 18,478 X X = X X = X X = X X X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X = X X = X X = X X = X X = X X X X = X X = X X X X = X L X = Items shown with an asterisk (') denote conduction through an interior surface to another room Page Total 26,176 Infiltration:[ 1.00 X 1:064 X 2,949 X 11.50 )( 0.276 / 60 � X 46 = 7,647 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,823 EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 43 of 53 • 0 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Maid Quarters Outdoor Dry Bulb Temperature 112 OF Floor Area 993.0 ffZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-21 Wall (W.21.2x6.16) (N) 90.0 X 0.0690 X 23.0 = 143 R-21 Wall (W.21.2x6.16) (E) 158.0 X 0.0690 X 33.0 = 360 R-21 Wall (W.21.2x6.16) (S) 436.0 X 0.0690 X 26.0 = 782 R-21 Wall (W.21.2x6.16) 329.0 X 0.0690 X 33.0 = 749 X X = X X = X X = X X = X X = Page Total 2,034 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1 (N) 0.0 X 18.2 + 25.0 X 18.2 = 455 2 (E) 0.0 X 18.2 + 48.0 X 34.8 = 1,671 3 (E) 0.0 X 18.2 + 72.0 X 34.8 = 2,507 4 (E) 0.0 X 18.2 + 40.0 X 34.8 = 1,393 5 (E) 0.0 X 18.2 + 6.0 X 34.8 = 209 X + X = X + X = X + X = X +1 X = Page Total 6,234 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 54.34 X 42 = 2.271 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 10,769 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 54.34 X 0.00523 = 1,268 Air Sensible CFM ELA AW ` TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,469 EneravPro 5.1 bv EnemySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 44 of 53 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 1,455.0 R2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (W) 154.0 X 0.0260 X 56.0 = 224 R-21 Wall (W.21.2x6.16) (E) 273.0 X 0.0690 X 33.0 = 622 R-21 Wall (W.21.2x6.16) (S) 183.0 X 0.0690 X 26.0 = 328 Wood Door (S) 24.0 X 0.5000 X 26.0 = 312 R-21 Wall (W.21.2x6.16) (VV) 78.0 X 0.0690 X 33.0 = 178 X X = X X = X X = X X = Page Total 1,664 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6 (E) 0.0 X 18.2 + 30.0 X 34.8 = 1,044 7 (E) 0.0 X 18.2 + 24.0 X 34.8 = 836 g (W) 330.0 X 18.2 + 0.0 X 34.8 = 6,003 X + X = X + X = X + X = X + X = X + X = X +1 X = Page Total 7,883 Internal Gain Btu/hr Occupants 1.0 Occupants X 2301 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 79.62 X 42 = 3,328 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,104 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4.771 X 0.94 X 79.62 X 0.00523 = 1,860 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,060 EnemvPro 5.1 by EnemySoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Pacie 45 of 53 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Living Outdoor Dry Bulb Temperature 112 OF Floor Area 2,547.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temoerature 70 OF Outdoor Daily Range: 34 OF Oaaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 2,547.0 0.0260 56.0 10.0 0.0690 23.0 424.0 0.0690 33.0 56.0 0.0690 26.0 164.01 0.0690 33.0 18.2 140.0 34.8 0.0 18.2 80.0 34.8 0.0 18.2 140.0 34.8 0.0 18.2 360.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 9 10 11 12 13 14 15 16 17 (]rientation (N) (N) (N) (E) (E) (E) (E) (S) (tM Btu/hr 3,708 16 965 100 373 1 5,1641 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 162.0 18.2 0.0 18.2 162.0 18.2 0.0 18.2 140.0 18.2 0.0 18.2 140.0 34.8 0.0 18.2 80.0 34.8 0.0 18.2 140.0 34.8 0.0 18.2 360.0 34.8 0.0 18.2 140.0 18.3 400.0 18.2 0.0 34.81 Page Total Btu/hr 2,947 2,947 2,547 4,8741 2,785 4,874 12,533 2,556 7,2761 Internal Gain kstu/nr 230 Occupants 1.0 Occupants X 230 Btuh/occ. = Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 139.37 X 42 = 5,826 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 61,106 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: Sensible X 0.94 X 139.37 X 0.00523 = 3,255 Air Sensible CFM ELA OW ,T GAIN FOR ROOM • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Namee 7611012013 Lippman Res ROOM INFORMATION DESIGN CONDITIONS Room Name Living Outdoor Dry Bulb Temperature 112 OF Floor Area 2,547.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area —U -Factor CLTD' Btu/hr X X = X X = X X = X X X X = X X = X X = X X = X X = Page Total o Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 1 g (►� 360.01'X 18.2 + 0.0 X 34.8 = 6,548 X + X X + X = X + X = X + X = X + X = X + X = X + X - X +1 X = Page Total 6,548 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 139.37 X 42 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 61,106 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 1 139.37 X 0.00523 = 3,255 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,455 Enem Pro5.1 by Ene Soft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Pa - e 47 of 53 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res' 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Outdoor Dry Bulb Temperature 112 OF Floor Area 1,390.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) (IM 635.0 X 0.0260 X 56.0 = 925 R-21 Wall (W.21.2x6.16) (N) 122.0 X 0.0690 X 23.0 = 194 R-21 Wall (W.21.2x6.16) (E) 456.0 X 0.0690 X 33.0 = 1,038 R-21 Wall (W.21.2x6.16) (49 260.0 X 0.0690 X 33.0 = 592 X X X X = X X = X X = X X = Page Total 2,749 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded .Fenestration Orientation Area GLF Area GLF Btu/hr 19 (N) 0.0 X 18.2 + 40.0 X 18.2 = 728 20 (N) 0.0 X 18.2 + 40.0 X 18.2 = 728 Y1 (N) 0.0 X 18.2 + 140.0 X 18.2 = 2,547 22 (W 0.0 X 18.2 + 270.0 X 34.8 = 9,400 23 (W) 0.0 X 18.2 + 56.0 X 34.8 = 1,950 24 (VV) 0.0 X 18.2 + 90.0 X 34.8 = 3,133 X + X = X + X = X +1 X = Page Total 18,484 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ: = 230 Equipment 0.0 Dwelling Unit X L 1,6001 Btu = 0 Infiltration: 1.064 X 0.94 X 76.06 X 42 = 3,178 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,642 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration' 4.771 X 0.94 X 76.06 X 0.00523 = 1.776 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,976 EnerqvPro 5.1 by EnerqvSoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 48 of 53 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest 1 & 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 1,440.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R. 38.2x 14.16) (IM 1,440.0 X 0.0260 X 56.0 = 2,097 R-21 Wall (W.21.2x6.16) (N) 156.0 X 0.0690 X 23.0 = 248 R-21 Wall (W.21.2x6.16) (E) 384.0 X 0.0690 X 33.0 = 874 R-21 Wall (W.21.2x6.16) (S) 416.0 X 0.0690 X 26.0 = 746 R-21 Wall (W.21.2x6.16) (lM 384.0 X 0.0690 X 33.0 = 874 X X = X X = X X = X X = Page Total 4,839 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 25 (N) 0.0 X 18.2 + 40.0 X 18.2 = 728 26 (N) 0.0 X 18.2 + 280.0 X 18.2 = 5,093 27 (N) 0.0 X 18.2 + 40.0 X 18.2 = 728 28 (S) 0.0 X 18.2 + 100.0 X 18.3 = 1,826 X + X = X + X = X + X = X + X = X +1 X = Page Total 8,374 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 78.80 X 42 = 3,294 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,737 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 78.80 X 0.00523 = 1,840 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,040 Enem Pro 5.1 by EneMySoft User Number: 6712 RunCode: 2013-06-10T17:53:58 ID: Page 49 of 53 RESIDENTIAL ROOM COOLING LOAD SUMMARY •Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Play Room Bowling Outdoor Dry Bulb Temperature 112 OF Floor Area 2,856.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temaerature 70 OF Outdoor Daily Range: 34 OF • Og)aaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W. 21.2x6.16) R-21 Wall (W. 21.2x6.16) Orientation (E) (E) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = Z956.0 0.0260 56.0 28.0 0.0690 23.0 860.0 0.0690 33.0 24.0 0.5000 33.0 490.01 0.0690 26.0 1,710.0 0.0690 33.0 X 18.2 + 168.0 X 18.2 = 84.6 X I J I= X 32.6 = Page Total Items shown with an"asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fnnectratinn 29 30 31 32 33 34 35 36 37 Orientation (N) (N) (N) (E) (E) (E) (E) (S) (tM Shaded Occupants X Dwelling Unit X Unshaded Btuh/occ. _ Btu = s it Area 1.0 10.0 GLF Area GLF 0.0 X 18.2 + 140.0 X 18.2 = 0.0 X 18.2 + 280.0 X 18.2 = 0.0 X 18.2 + 168.0 X 18.2 = 84.6 X 16.0 + 95.4 X 32.6 = X 32.6 = 84.6 X 16.0 + 95.4 32.6 84.6 X 16.0 + 95.4 X = 32.6 84.6 X 16.0 + 95.4 X = X 18.3 = 140.0 X 18.2 + 0.0 84.6 X 18.2 + L 95.4 X Page Total Gain Occupants X Dwelling Unit X Btuh/occ. _ Btu = s it 1.0 10.0 2301 1 1,6001 Infiltration: 1.064 X 0.94 X 156.28 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Occupants 1.o Occupants X 2001 Btuh/occ. _ Infiltration: 4,771 X 0.94 X 156.28 X 0.00523 = Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM Btu/hr 4,304 44 1,958 396 879 11 Btu/hr 2,547 5,093 3,056 4,464 4,464 4,464 4,464 2,547 4,8601 Btu/hr 230 0 6,533 54,197 Btu/hr 200 3,650 • • • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name Theater Outdoor Dry Bulb Temperature 112 OF Floor Area 882.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 Roof(R.38.2x 14.16) 882.0 X 0.0260 X 77.0 = 1,766 R-21 Wall (W.21.2x6.16) (N) 324.0 X 0.0690 X 31.0 = 693 R-21 Wall (W.21.2x6.16) (E) 324.0 X 0.0690 X 44.0 = 984 R-21 Wall (W.21.2x6.16) (S) 324.0 X 0.0690 X 38.0 = 850 X X = X X = X X = X X = X X = Page Total 4.292 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = X +1 X = Page Total 0 Internal Gain Btu/hr Occupants 1.0 Occupants X 230 Btuh/occ. = 230 Equipment 0.0 Dwelling Unit X 1,200 Btu = 0 Infiltration: 1.064 X 0.94 X 48.26 X 42 = 2,017 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,539 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 48.26 X 0.00523 = 1,127 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,327 EnemvPro 5.1 by Ene2vSoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 51 of 53 • 0 I RESIDENTIAL ROOM COOLING LOAD SUMMARY Lippman Res 1 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 2,949.0 8' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranae: 34 OF Onaaue Surfaces R-38 Roof(R.38.2x 14.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Orientation (►M (S) I Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = Z949.0 0.0260 56.0 280.0 0.0690 23.0 670.0 0.0690 33.0 200.0 0.0690 26.0 164.0 0.0690 33.0 18.2 30.0 18.3 0.0 18.2 100.0 18.3 0.0 18.2 70.0 I 173.8 18.2 46.2 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration 38 39 40 41 42 43 44 45 46 Internal Gain nrientatinn Btu/hr 444 1,526 359 373 1 6,9961 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 18.2 30.0 18.2 0.0 18.2 130.0 34.8 0.0 18.2 30.0 34.8 0.0 18.2 30.0 18.3 0.0 18.2 100.0 18.3 0.0 18.2 70.0 18.3 173.8 18.2 46.2 34.8 65.8 18.2 74.2 34.8 65.8 18.2 74.21 34.81 Page Total 546 4,526 1,044 548 1,826 1,278 4,770 3,780 3,7801 22,097 1.0 Occupants X 230 Btuh/occ. _ 230 0.0 Dwelling Unit X 1,600 Btu 0 I Infiltration: 1.064 X 0.94 X 161.37 X 42 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,8491 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 161.37 X 0.00523 = 3,769 Air Sensible CFM ELA AW s • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project NameDate Lippman Res 6/10/2013 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Outdoor Dry Bulb Temperature 112 OF Floor Area 2,949.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 47 (W) 65.8 X 18.2 + 74.2 X 34.8 = 3,780 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 3,780 Internal Gain Btu/hr Occupants 1.0 Occupants X 2301 Btuh/occ. = 230 E ui ment 0.0 Dwelling Unit X 1,600 Btu = 0 Infiltration: 1.064 X 0.94 X 161.37 X 42 = 6,745 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 39,849 Latent Gain Btu/hr Occupants 1.0 Occupants X 200 Btuh/occ. = 200 Infiltration: 4,771 X 0.94 X 161.37 X 0.00523 = 3,769 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,969 Ene Pro 5.1 by Enemysoft User Number: 6712 RunCode: 2013-06-10717:53:58 ID: Page 53 of 53