Loading...
13-0962 (BLCK)f• s � P.O. BOX 1504 78,-.495 CALLE TAMPICO LA QUINTA, CALIFORNIA.92253 '_ BUILDING & SAFETY DEPARTMENT CLIBUILDING PERMIT Application Number: 13-00000962 Property Address: 81540 BAFFIN AVE APN: 767-200-998-101 -330762- Application description: WALL/FENCE Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 72348 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under. provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business,�nd rofessionals Code, and my License is in full force and effect. License Class: B ! License No.: 915336 f�Q !;///, � i _ s � D��✓Contractor: U OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county` that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - (_ 1 I, as owner of the property, am exclusively contracting with licensed. contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. , B.&P.C.for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: JAMES & LINDA LIPPMAN 11766 WILSHIRE BLVD. 15TH FLOOR LA QUINTA, CA 92247 Contractor: DBCA INC P.O. BOX 1482 LA QUINTA, CA 92247 (760)393-5271 Lic. No.: 915336 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760).777-7153 Date: 8/0i/13 - -----------------------------------7----------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is n ,,..,,issued. �(/�yr•nave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor �(_.�/�-- Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier TRAVELERS Policy Number YJUB282D7797-12 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to ect to the workers' compensation laws of California, and agree that, if I should become suc to the workers' compensation provisions of Section 3700 of the Labor Code, 1.6611 ftlr hwi co m y with th r ision'. Applicant: l/ aj✓ WARNING: FAILURE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for _ whose benefit work is performed under or pursuant to any permit issued as a iesult of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes.null and void if woik is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abovVn!'2". r anon is correct. I agree to comply with all city and county ordinances and state laws relating to building constr ctio ,and hereby authorize presentatives of this county to enter upon the above-mentioned property,.for in9pecti :zs . Date --2-hi Signature (Applicant or Agent): i/r� LQPERMIT Application Number . . . 13-00000962 Permit . . . . WALL/FENCE PERMIT 2013 Additional desc . Permit Fee . . 390:39 Plan Check Fee .00 Issue Date Valuation . . . . 72348 Expiration Date 1/28/14 Qty Unit Charge Per Extension 1.00 47.1900 LS MISC WALL, FIRST 100 LF 47.19 24.00 14.3000 EA MISC WALL, ADDL 50 LF 343.20 ----------------------------------------------------------------- Special Notes and Comments ----------- BLOCK WALL - INSTALL 330 L.F. OF 7FT. 4 IN. HIGH, PROTO II WALL (PER APPROVED PLAN), 39 L.F. OF 5 FT. 4 IN. HIGH. " GARDEN WALL, 10 L.F. OF 6 FT. HIGH GARDEN WALL, 148 L.F. OF 8 FT. HIGH GARDEN WALL (ALL GARDEN WALLS ARE TO BE _ INSTALLED PER APPROVED PROTO II PLANS). INSTALL 461 L.F. OF 2FT. 8 IN. RETAINING WALL, 106 L.F. OF 1 FT. 4 IN. RETAINING WALL, 127 L.F. OF 2 FT. RETAINING WALL, 39 L. -F. OF 3 FT. 4 IN. RETAINING WALL, 39 L.F. OF 3 FT: 4 IN. HIGH RETAINING WALL (ALL RETAINING WALLS TO BE.BUILT PER ATTACHED CITY APPROVED ORCO BLOCK DETAIL), 2010 CALIFORNIA BUILDING CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, .WALLS 60.06 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 390.39 .00 .00 390.39 Plan Check Total .00 .00 .00 .00 Other Fee Total 61.06 .00 .00 61.06 . Grarid Total 451.45 .00 .00 451.45 LQPERMIT F Bin # Qty of La Quinta -Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico 262013 La Quinta, CA 92253 - (760) 777-70 1 QA1, Or Building Permit Application and Tracking 91JIAI, Permit # Project Address:oE­ C2 6LD Owner's Name: h4 poo�P/l�E- - A. P. Number: Address: L Legal Description: City, ST, Zip:/CS I+AjC Z4,,,S, 2- Contractor:blscoo�i� Bull-bg-PIS -7 Telephone: - Address: go — Project Description: A4K' W&L- PVU?'V-' T� City, ST, Zip: 0.1617- rA A) 33 o 4 Cs Aom L, I JAL& 4/ Telephone: ......... .......... . . . . . . . . . . . . . . A) IVX/ z r 9*1 State Lia #: City Lic. Arch., Engr., Designer: 6-A-A,4VE 819CIL 4- /NT�j2pgl2�S b).• 0 Address: City., ST, Zip: �yq?0.6 dl -V z yLleA Telephone: E~pair DMT -0-11 144 0 Sq. Ft.: # #�Units: State Lic. #: Name of Contact Person: jSro Telephone 4 of Contact Person: Estimated Value of Project: 17 --7 2 ICANT: DO NOT. WRITE BELOW THIS LINE N Submittal Reqld Recld TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount 'Structural Cales. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Title 24 Cales. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2". Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees C N NOTES: " 15 RUN HORIZONTAL JOINT REINFORCING NOTE: GENERAL NOTES 1. POST TENSIONED ROD. 6. #4 REINFORCING WITH 6 HOOK 7. END OR CORNER OF WALL MAY START 11. PROTO II WALL. • SEE 8" ROD VARIANCE SPEC AT NOTES 2. END OF WALL. INTO FOOTING BELOW. FILL WITH WITH #4 VERTICAL REBAR, GROUT SOLID 12. 16 MASONRY PIER WITH 4 #4 VERTICAL THROUGH PIER STOP AT FACE OF NO. 5 AT BOTTOM OF WALL SCHEDULE. 1. THE PROTO-II WALL IS DESIGNED FOR WIND AND SEISMIC FORCES AS REQUIRED AND APPROVED 3. RODS AT 12" EITHER SIDE OF A GROUT OR 8 HIGH LIFTS OF MORTAR. THEN SPACE FIRST POST TENSION AND 1 #2 TIE AT TOP OF PIER. PIER AT CONTRACTORS OPTION. 8" VARIANCE APPLIES TO ALL RODS BY THE LOCAL JURISDICTION. SEE SCHEDULES FOR EXPOSURE, WIND FORCES, POST TENSIONED CONTROL JOINT OR END OF WALL. 6A. POST TENSIONED ROD SPACING PER ROD PER SCHEDULE. REBAR MAY 13. 12 SQUARE MASONRY PIER WITH 16. ALL VERTICAL MASONRY PIER REINFORCING EXCEPT THOSE AT CONTROL JOINTS ROD SPACING, FOOTING SIZES, ETC. CONTRACTOR IS RESPONSIBLE TO VERIFY REQUIREMENTS IN 4. NOT USED. SCHEDULE BUT NOT TO EXCEED SUBSTITUTE FOR P.T. ROD AT CORNER 1 #5 VERTICAL. SHALL HAVE 6" HOOKS AT BOTTOM AND END OF WALL. WITH BUILDING DEPARTMENT AND OWNER. ALL WORK IS TO BE PERFORMED THE APPROVED SITE PLAN SOILS REPORT AND/OR APPLICABLE CODE REQUIREE ACCORDANCE WITH5. NOT USED. 4'-8" ON EITHER SIDE OF THE OR END OF WALL. 14. LINE OF FOOTING BELOW. FOOTING AT AND EXTEND A MINIMUM OF 8" MENTS. 2. THESE DESIGNS ARE NOT TO BE USED FOR RETAINING EARTH (LEVEL BACKFILL) ABOVE 1'-4" FOR CONTROL JOINT OR END OF WALL. 8. NOT USED. PROTO II WALL PER PLANS AND INTO FOOTING. • AT CONTRACTORS OPTION, THE WALL 4' PROTO-II, 2'-0" FOR 6' PROTO-II, AND 2'-8- FOR 8' PROTO-II AS MEASURED FROM LOW 9. NOT USED. SCHEDULES. FOOTING AT PIER SHALL 17. TYPICAL ROD SPACING PER SCHEDULE "S". EXPANSION JOINT MAY OCCUR AT SOIL TO HIGH SOIL. NO SURCHARGES WITHIN 5-0 OF WALL ARE ALLOWED. SEE DETAIL 10. (1) (6) 10. NOT USED. BE 12 THICK AND 4��WIDER ALL 18. MAXIMUM ROD SPACING FROM CONTROL THE FACE OF THE PIERS AS SPECIFIED 3. FOOTINGS TO BE LEVEL IF GROUND SLOPES THE FOOTING SHALL BE STEPPED. EACH STEP AROUND THE PIER. JOINT MAY BE 1/2 THE TYPICAL ROD IN GENERAL NOTE 14. SHOULD BE PROPER HEIGHT TO FIT BLOCK TYPE USED. ALL EXCAVATIONS SHOULD BE CLEAN AND "S", CONTAIN NO LOOSE EARTH OR FOREIGN MATTER. SPACING S FOR EXAMPLE, IF 4. SOIL SHALL BE FIRM AND COMPACTED PRIOR TO PLACEMENT OF CONCRETE. PRIOR TO FOUNDATION (1) TYPICAL ROD SPACING FROM SCHEDULE IS EXCAVATION, CONTRACTOR SHALL VERIFY VIA SOILS REPORT THAT SITE SOILS CONDITIONS MEET OR (2) (1) 8'-0", MAX ROD SPACING FROM A CONTROL EXCEED AN ALLOWABLE PASSIVE BEARING PRESSURE OF 200 PSF/FT STARTING AT THE TOP OF 6A �, JOINT MAY BE 8'/2=48". GRADE(I.E. NO TOP SOILS ARE NEGLECTED FOR PASSIVE) AND A MINIMUM ALLOWABLE BEARING PRESSURE OF 1000 PSF. (13) (16) 5. SOIL SHALL BE WELL DRAINED FOR FOOTINGS AND FOUNDATIONS, USE CONCRETE WITH A MIN. OA END OF WALL B END OF WALL (1) (14) (1) STRENGTH OF 2,500 PSI - TYPE II CEMENT (TYPE V WHERE REQUIRED BY OWNER, SOILS ENGINEER OR JURISDICTION). CONCRETE SHALL BE A MIN. OF 48 HOURS OLD PRIOR TO FINAL TENSIONING. (15) r -- --� (15) 6. LAP REINFORCING STEEL: LAP = 26" FOR #4 BARS 40" FOR #5 BARS IN MASONRY. (1) O RETURN CONDITION _ L------- ---------- 32"/39" LAP IN CONCRETE FOR #4 OR #5 BAR RESPECTFULLY. ---------- v - J 7. CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 AND BE 2,000 PSI MIN. (F'M DESIGN 2) _ _ - - CRITERIA FOR BLOCK IS BASED ON 2000 PSI). BLOCK SHALL BE A MIN OF 7 DAYS OLD PRIOR' ----------------- r------ ----- TO ROD TENSIONING. STANDARD HEAD AND BED JOINT BLOCKS WITH MORTAR MAY BE USED OR INTERLOCKING BLOCKS MAY BE USED. OC END OF WALL " rA 8. MORTAR SHALL BE TYPE S, 2000 PSI MIN. MORTAR MAY BE USED AS GROUT IN 8' HIGH LIFTS. " MORTAR MUST BE A MIN. OF 4 HOURS OLD PRIOR TO INITIAL TENSIONING AND 24 HOURS OLD Oq ALTERNATE CONTROL JOINT SPEC. AT CONVENTIONAL REINF. +, 12 12 PRIOR TO FINAL TENSIONING. 9. FIRST MASONRY COURSE MAY BE SET IN FRESH CONCRETE FOOTING. HEAD JOINTS MAY BE i, (1 R) (17) _, OMITTED IN FIRST COURSE FOR WEEP HOLES. TYPICAL CONTROL JOINT SPEC. MASONRY NOTE: B CONTROL MAKE A CLEAN VERTICAL AT POST TENSION ROD. JOINT BREAK OF ALL MATERIAL IN CONTROL JOINT. SPECIAL WALL CONDITIONS AND OPTIONS �o 9 1U UATUUHi (6) (7) NOTES: 1. FENCE WALL - DETAIL NOT SHOWN FOR CLARITY. 2. FINISHED GRADE. 3. NO SLOPING ADJACENT GRADE ALLOWED. 4. FACE OF FOOTING TO TOP OF SLOPE. 5. BOTTOM OF SETTING PAD. 6. SEE SCHEDULE FOR WALLS UP TO 6'-0" HIGH. 7. SEE SCHEDULE FOR WALLS ABOVE 6'-0" HIGH. NOTE: THIS DETAIL DESCRIBES THE MINIMUM DISTANCE REQUIREMENTS FOR THE LOWEST FOOTING EDGE TO FINISHED GRADE. SCHEDULE FOR WALLS UP TO 6'-0" FACE OF FOOTING TO TOP OF SLOPE. FACE OF FOOTING TO TOP OF SLOPE. MIN. DEPTH OF DIP OR OR TRENCH FOOTING 13" MINIMUM DEPTH OF DIA PIER 12" OR MORE 2'-4" 3'-6" 6" TO 11" 2'-7" 3'-10" 3 TO 5 2'- 1 O 11 4 -0 SCHEDULE FOR WALLS ABOVE 6'-0" UP TO 9'-4" FACE OF FOOTING TO TOP OF SLOPE. ADDED DEPTH OF DIP OR OR TRENCH FOOTING 13" ADDED DEPTH OF DIA PIER 36" OR MORE 0" 0" 30" 6" 6" 24 9 910 12" 15" 15" 6 18 18 3" 20" 20" 5'-0" TO DAYLIGHT DETAIL FOR FOOTINGS NOTES: NO SCALE 1. GROUT SOLID ONLY AT POST -TENSION 7. A MODIFIED 6" THICK PROTO II ROD CELLS BELOW GRADE. WALL MAY BEGIN WITH A SOLID 2. LOW SOIL. 8" HIGH GROUTED COURSE OF 3. CONCRETE FOOTING. 8" BLOCK. THE SOIL RETAINAGE 4. HIGH SOIL.. MAY THEN INCREASE TO 2'-8". 5. PROTO II FENCE WALL. FOR 8" WIDE WALLS USE A 10" WIDE 6. * V-4" MAX. AT 4" PROTO II. FLANGE, 6" DEEP AT TOP OF FOOTING. * 2'-0" MAX. AT 6" PROTO II. 8. HEAD JOINTS IN FIRST COURSE * 2'-8" MAX AT 8" PROTO II. OMITTED FOR WEEP HOLES, SEE GENERAL NOTE 9. 9. 2" SOIL MIN OVER FOOTING. ROD SPACING AND FOOTING SELECTION NOTES: A. FOR ALL EXPOSURE C CONDITIONS WITH FENCE WALL HEIGHT "F" OF 3'4" OR LESS, ASSUME MINIMUM WALL HEIGHT OF F+R+1'4". EXAMPLE, FOR A 3'4"HIEGHT FENCE WALL WITH 2'8" RETAINING, USE PROTO II FENCE WALL SCHEDULE HEIGHT "H"= 3'4" + 2'8"+ 1'4"= 7'4". B. FOR ALL EXPOSURE C CONDITIONS WITH FENCE WALL HEIGHT "F" GREATER THAN 3'4", ASSUME ,5) MINIMUM WALL HEIGHT OF F+R+8". EXAMPLE, FOR A 5'4" HEIGHT FENCE WALL WITH 2'8" RETAINING, USE PROTO II FENCE WALL SCHEDULE HEIGHT "H"= 5'4" + 2'8" + 8" = 8'8". 11) C. FOR ALL EXPOSURE B CONDITIONS WITH FENCE WALL HEIGHT "F" OF 6'0" OR LESS, ASSUME MINIMUM WALL HEIGHT OF F+R+1'4". EXAMPLE, FOR A 6'0" HIEGHT FENCE WALL WITH 8" RETAINING, ;2) USE PROTO II FENCE WALL SCHEDULE HEIGHT "H"= 6'0" + 8"+ 1'4" 8'0'. D. FOR ALL EXPOSURE B CONDITIONS WITH FENCE WALL HEIGHT "F" GREATER THAN 6'0", ASSUME MINIMUM WALL HEIGHT OF F+R+8". EXAMPLE, FOR 3� A 6'8" HEIGHT FENCE WALL WITH 8" RETAINING, USE ��- PROTO II FENCE WALL SCHEDULE HEIGHT "H" = 6'8" + 8" + 8" = 8'0". DETAIL AT SOIL RETAINAGE NO SCALE (1 (15) - RETURN CONDITION - (1 - - x N 12" NOTES: (1) 1. PROTO II FENCE WALL PER 12. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER DETAIL 8 PRODUCT DATA SHEET. 8' PROTO II A. PROTO II TENSION ROD SHALL BE CONTINUOUS 7/16" DIA STRAIGHT, THREADED FULL CROSS SQUARE (6' MINIMUM LAP). BOTH ENDS AND SHALL HAVE POST TENSION MIN. 12" EMBED INTO MASONRY POST TENSION RETAINING WALL WITH PLATE STRAIGHT RODS THREADED BOTH ENDS FOR ADDITIONAL LIFTS. MIN. OF 3" 'L' HOOK, OR "J" WASHER. 2. SOLID GROUTED RETAINING ROD SPACING ON CENTER WALL. DESIGNED BY OTHERS. 14. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND INSTALLER TO VERIFY RETAINING 20' ON CENTER IN STUCCOED WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. SEE WALL DESIGNED BY OTHERS WILL PROTO II FENCE WALL. SUPPORT THE PROTO II FENCE 2. WALL ABOVE. 3. FINISHED GRADE. 4. 2 #3 MIN. IN BOND BEAM - LAP 20" WHERE OCCURS. 5. BACKFILL SHALL BE NON - 7/116" DIA FULL HEIGHT POST TENSIONED EXPANSIVE SOILS. SEE SOILS REPORT. 6. COUPLER IF PARTIAL HEIGHT ROD IS TOP FOR NUT ATTACHMENT. USED IN LIEU OF FULL HEIGHT ROD. 7. 1/4"x1"x2" EMBEDMENT PLATE WITH 1/2" THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF FINAL TENSIONING BY A DEPUTY NUT ABOVE PLATE AND 1/2" COUPLER (6) BELOW PLATE (OR (2) 1/2" NUTS). (3) JNOTE: PROTO II FENCE WALL CAN BE (5) PLACED AT ANY LOCATION ON THE (2) TOP OF THE RETAINING WALL (4)-7.. (FLUSH OR CENTERED) BUT THE y� i" POST TENSIONED ROD SHALL AT ALL TIMES BE PLACED BETWEEN THE 2 REINFORCING BARS AT (7) THE TOP OF THE RETAINING WALL. PROTO II WALL CONNECTION TO TOP OF CONVENTIONAL MASONRY RETAINING WALL 1 Co 2 Go 3 co 4 Go 5 co 6 co 7 Go 8 co 9 (2) HORIZONTAL JOINT REINFORCING NO SCALE NOTES: 1. TOP OF FOOTING. 2. PROTO II WALL - VERTICAL POST TENSIONED ROD NOT SHOWN FOR CLARITY. 3. 8" HIGH COURSES ARE SHOWN IN DETAIL. OTHER BLOCK SIZES MAY BE USED AS REQUIRED BY THE FENCE WALL DESIGN. HORIZONTAL JOINT REINFORCING (REF. GENERAL NOTE #12)* 1. HORIZONTAL JOINT REINFORCING SHALL BE PLACED AT THE MORTAR JOINTS #2 & #3 BELOW THE PLATE WASHER AND 2'-0" O.C. THEREAFTER UNTIL THE TOP OF FOOTING IS REACHED. (e.g. A NOMINAL 6'-0" HIGH WALL WOULD HAVE JOINT REINFORCING IN A TOTAL OF THREE COURSES). NO SCALE C, (1 2) 10. REINFORCING REBAR SHALL CONFORM TO ASTM A615; Fy = 40,000 PSI. 11. PROM -II HARDWARE IS DEFINED AS: TENSION RODS, BEARING PLATES, COUPLERS, NUTS, ALL 1 (14) - (1-6)_ --- 1 THREADS, DIRECT TENSION INDICATORS ( A DIRECT TENSION INDICATOR (DTI) IS A COMPRESSIBLE WASHER) AND PLASTIC SADDLES. ALL OF THIS HARDWARE SHALL BE SUPPLIED BY ONLY AN (15) 7/APPROVED ILICENSEE 6 DIA WITH /2 ROLL THREADS CONFORMING TO ASTM A615 (FY RO 60000 SI) AND j, ________ _ HAVE STEEL CHEMISTRY SO THAT BENDING AND THREADING CAN BE ACCOMPLISHED WITHOUT - _ DAMAGE TO THE POST TENSION ROD. AREA OF POST TENSION ROD = .1503 SQUARE INCHES. ------------------ k x _ _ _ • _ _ _ _ _ _ _ _ _ _ BEARING PLATES ARE 1/4' THICK (Fr -50 KSI) SEE DETAIL 5 FOR WIDTHS. 1/2- COUPLERS r �o PER ASTM A563 GRADE A. AND THE COUPLER MUST FULLY ENGAGE THE UPPER AND LOWER ROD, FULLY ENGAGED AS DEFINED AS 1/2" MIN. INTO COUPLER. 1/2' NUTS ARE TO BE GRADE 8, IPER ASTM A325. 1/2" ALL THREADS PER ASTM A307, GRADE 60. DIRECT TENSION INDICATOR (D -TI - " COMPRESSIBLE WASHER) IS PER ASTM F959 TESTING PROCEDURES. PLASTIC REBAR SADDLES O 12 16 12 ARE NON-STRUCTURAL c9� i r (5) 16" MIN. DIP FOOTING PROFILE x PLAN TOP OF FENCE DETAIL REINFORCING PER NOTE #12. 5. CENTER WEB BELOW. NO SCALE NOTES: 3 1. PROTO II WALL. 2. 3" MORTAR COVER AROUND (1) 2 COUPLER AND/OR POST TENSIONED ROD FOR CORROSION PROTECTION. 3. 7/16" DIA FULL HEIGHT POST TENSIONED RODS WITH 3" HOOKS. ROLL THREADS AT TOP FOR NUT ATTACHMENT. NO VOIDS OR JUNCTION OF POST TENSION ROD AND REINF. BARS ALLOWED. PROVIDE CONSOLIDATION OF CONCRETE VIA VIBRATION, RODDING OR OTHER APPROPRIATE MEANS. 4. THICKEN FOOTING TO PROVIDE 3" MIN. COVER AS REQUIRED AROUND ANCHOR BOLT. 5. SEE SCHEDULE AND OTHER DETAILS. - G �(3) rr M U FOOTING ELEVATION AT POST TENSIONED ROD NO SCALE NO SCALE NOTES: 1. 4" NOMINAL (3 5/8" ACTUAL OR 6" NOMINAL 5 5/8" ACTUAL OR 8" NOMINAL �7 5/8" ACTUAL MASONRY. 2. HORIZONTAL JOINT REINF - SEE NOTE #12. v(1)v 3. #4 CONTINUOUS AT 4" & 6" PROTO II '7 #5 CONTINUOUS AT 8" PROTO II, 4. CONCRETE SETTING PAD. NO VOIDS OR (2) HONEYCOMBING OF CONCRETE AT JUNCTION _ OF POST TENSION ROD AND REINF. BARS ALLOWED. PROVIDE CONSOLIDATION OF _ CONCRETE VIA VIBRATION, RODDING OR OTHER APPROPRIATE MEANS. = 5. DASHED LINE INDICATES LINE OF DIP FOOTING ~ OR LINE OF CONT TRENCH FOOTING. 6. DEPTH OF CONTINUOUS TRENCH FOOTING. o_ c _ (2) 7. * 8" AT 4" AND 6" PROTO IL N o- _ 7A. FOR 8" WIDE WALLS USE 10" WIDE FLANGE, Q o 6"DEEP AT TOP OF FOOTING. N 8. 3" MORTAR COVER AROUND COUPLER rl� :� AND/OR POST TENSIONED ROD FOR CORROSION PROTECTION AT FIRST COURSE. N fr 9. VERTICAL REINFORCING AT TRENCH, AND U_ (8) (3) DIP FOOTINGS FOR WALLS OVER 6'-0" co(7A) HIGH. USE #4 x AT THE 6" AS ER STRAIGHT "J" OR "L" OK �_ REQUIRED OF \ (11) EACH DIP FOOTING AT DIP FOOTING DESIGN. i (4) REBAR SPACING IN TRENCH FOOTING FOR WALLS 6'-8" TO 8'-0" SHALL MATCH `o �`' \ (5)SPACING OF DIP FOOTINGS. ABOVE 8'-0l" -H i(10) AND WHERE DIP FOOTING SPACING NOT (9) AVAILABLE, SPACE VERTS AT 24" O.C. MAX. 10. A CONTRACTOR OPTION IS TO STAB THE #4 VERTICAL REBAR DOWN INTO THE DIP, PIER "(7) OR CONTINUOUS TRENCH FOOTING AND EXTEND IT +/-8" INTO THE FIRST COURSE OF BLOCK. 11. 2" SOIL MIN OVER FOOTING. 3 TYPICAL WALL SECTION AT DIP FOOTING AND TRENCH FOOLING NO SCALE PROTO II FENCE WALL SCHEDULE - CALIFORNIA 2010 CSC AND 2009 IBC EXPLANATION OF WIND LOAD DESIGNATIONS: ASCE 7-05I = 0.87 (CATEGORY I TABLE 6-1) qz = 0.00256 x Kz x Kzt x Kd x V2 x I (EQ. 6-15) F = qz x G x Cf x Af (EON 6-28) Kz = 0.57 EXP B, 0.85 EXP C (TABLE 6-3) G = 0.85 (RIGID STRUCTURE SEC 6.5.8) Kzt = 1.0 FOR H S 15'-0' (SECTION 6.5.7.1 15) *Cf = 1.3 x 1.1 (FOR S/H = 1 AND B/S 2 10) Kd = 0.85 (SIMILAR TO SOLID SIGN, TABLE 6-4) As = ASSUME 1 SQUARE FOOT. V = VELOCITY 3 SECOND WIND GUST * 1.1 MULTIPLIER USED TO ADJUST FOR OBLIQUE ADJUSTMENT FACTOR PER FIGURE 6-20 FOOTNOTE 3. WIND WALL 12. HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE DIAMETER WIRE AND PLACED PER DETAIL 8 6' PROTO II 8' PROTO II AND CONFORM TO ASTM A82 LADDER TYPE, 9 GAGE DIAMETER. LAP JOINT REINFORCING ONE CONTINUOUS INC. FULL CROSS SQUARE (6' MINIMUM LAP). HEIGHT POST TENSION 13. IN LIEU OF FULL HEIGHT RODS, CONTRACTOR MAY USE SHORTER RODS, 1/2' COUPLERS AND POST TENSION NO SCALE STRAIGHT RODS THREADED BOTH ENDS FOR ADDITIONAL LIFTS. MIN. OF 3" 'L' HOOK, OR "J" (480) 774-1701 FAX www.ctsaz.com HOOK AT END OF TENSION ROD. ROD SPACING ON CENTER ROD SPACING ON CENTER 14. VERTICAL CONTROL JOINTS TO BE PLACED AT MAX. 36' O.C. IN ALL NON -STUCCOED WALLS AND NOTES: 20' ON CENTER IN STUCCOED WALLS WITH CLEAN VERTICAL BREAK OF ALL MATERIALS. SEE 1. PROTO II FENCE WALL. DETAIL 1 FOR ROD SPACING AT CONTROL JOINTS AND WALL ENDS. 2. 3" MORTAR COVER AROUND COUPLER AND/OR 15. NO COUPLERS MAY OCCUR DIRECTLY BELOW AND IN CONTACT WITH THE BEARING PLATE. DETAIL 4 FOR POST TENSIONED ROD FOR CORROSION 16. TENSION RODS MAY BE STABBED INTO WET CONCRETE OR TIED IN PLACE AT CONTRACTOR OP1110N; PROTECTION. SEE DETAIL 6, NOTE NO. 3. AT CONTRACTOR OPTION, VERTICAL REBAR MAY BE STABBED DOWN 3. 7/116" DIA FULL HEIGHT POST TENSIONED INTO THE DIP, SEE DETAILS 3 AND 4. RODS WITH 3" HOOKS. ROLL THREADS AT 17. A PROM -II DTI (COMPRESSIBLE WASHER) SHALL BE INSTALLED AT EVERY TENSION ROD BETWEEN TOP FOR NUT ATTACHMENT. THE BEARING PLATE AND NUT W/ THE DTI TABS FACING UP AGAINST THE BOTTOM OF THE NUT. 4. CONC. FTG. - NO COLD JOINTS PERMITTED. THE SPECIAL DEPUTY INSPECTION REQUIRED AT TIME OF FINAL TENSIONING BY A DEPUTY 5. TRENCH MAY BE OVER EXCAVATED AS SHOWN- INSPECTOR SHALL VERIFY FINAL TENSIONING TO 6,000 POUNDS BY 1 OF 2 METHODS; METHOD 1; o LJ f Co FILL. W/ COMPACTED FILL OR CONCRETE. VISUAL INSPECTION OF DIRECT TENSION INDICATOR (DTI), TABS FACING UP AND COLLAPSED 6. 13`0 x S-9" DEEP CIRCULAR PIER FTG. MAY AGAINST NUT W/ NO LIGHT LEAKAGE BETWEEN THE PROTO-II DTI AND BOTTOM OF NUT. METHOD ~ Q� cn Q 2: USE OF A CALIBRATED TORQUE WRENCH TORQUED TO 55FT/LBS. (DTI MUST STILL BE PLACED C) w�Q x_ CL m O � < X M BE USED IN LIEU OF DIP FTG. SPACING AND WITH METHOD 2. NO VISUAL INSPECTION OF DTI REQUIRED WHEN USING METHOD 2). INSPECTfOR J SETFTING PAD TO REMAIN THE SAME. SHALL OBSERVE THE USE OF THREAD LUBRICANT, THE POSITION OF PLATE ON BLOCK, AND 7. NO VOIDS OR HONEYCOMBING OF CONC. AT INTEGRITY OF MORTAR JOINTS. AND PROVIDE A SIGNED REPORT TO ALL APPROPRIATE PARTIES. 8'-0' JUNCT ON OF POST TENSION ROD AND MASONRY DESIGN IS BASED ON THIS SPECIAL INSPECTION. U.S. PATENTED 7,454,870 REINFORCING BARS ALLOWED. PROVIDE 18.*DESIGNS ILLUSTRATED ON THIS PRODUCT DATA SHEET ARE FOR PROM -II WALLS AND PROTO-II 694' CONSOLIDATION OF CONCRETE VIA VIBRATION, RETAINER WALLS UP TO A COMBINED HEIGHT OF 10'-0'. ADDITIONAL SCHEDULES ARE AVAILABLE 14'-0' RODDING OR OTHER APPROPRIATE MEANS. FOR PROM -II WALLS UP TO 13'-4' HIGH AND HIGHER 'HYBRID' PROTO-II WALLS. 8. VERTICAL FOOTING REINFORCING AT WALLS 19. ALL CONVENTIONALLY REINFORCED PILASTERS REQUIRE SPECIAL INSPECTION. SPECIAL INSPECTION OVER 6'-0" HIGH USE INCLUDES CONTINUOUS OBSERVATION OF GROUTING ALONG WITH A PRE -GROUT INSPECTION THE 21 #4 xIN CENTER OF PRE -GROUT INSPECTION INCLUDES VERIFICATION OF THE LOCATION OF STRUCTURAL ELEMENTS. 51-4' STRAIGHT "J" 624" DIP OR PIER. GRADE OF REINFORCEMENT AND OVERALL WORKMANSHIP AND QUALITY OF MATERIALS BEING USED, 12'-0' OR "L" OK I FOR CONFORMANCE WITH CONSTRUCTION DOCUMENTS. 9. THI1S DETAIL SHOWS THE POST TENSION ROD 20. END ZONES FOR WIND DESIGNS ARE EXCLUDED. I.E. Cf = 1.3. 6'-0' CENTERED IN THE DIP FTG. - HOWEVER THE 24' POST TENSION ROD SPACING IS INDEPENDENT . 6 -8 2 -8 OF THE DIP FTG. AND THEY DO NOT NEED TO NOTES: 10. LINE UP. NOT USED IN WALLS 6'-0" AND UNDER. 1. POST TENSION ROD. 11. VERT. REINF. REQ'D WHEN USING CIRCULAR 2. NUT. 3. COMPRESSED DTI INDICATOR - NO LIGHT PASSES 294' PIER DETAIL IN LIEU OF "DIP". SEE NOTE 6 BELOW WALL SCHEDULE. BETWEEN BOTTOM OF NUT AND DTI WHEN / \ TOP 12. A (CONTRACTOR OPTION IS TO STAB THE #4 4. PLA�TENSIONED. 8'-0' VERTICAL REBAR DOWN INTO THE DIP, PIER 5. COLLAPSIBLE TABS. 3'-4' OR CONTINUOUS TRENCH FOOTING AND EXTEND 29' 6. MINIMUM TENSION TO BE 6,000 LBS LOAD AND - IT +/-8" INTO THE.FIRST COURSE OF BLOCK. 2'-8' 5'4' 30' CONFIRMED BY ONE OF TWO METHODS PER * 9'-4' _ - NOTE "C" BELOW. - 32' ` / A. PROTO-II DTI TO BE USED AT EACH TENSION ROD, * SEE GENERAL NOTE 18. • TABS FACING UP AGAINST BOTTOM OF 1/2" NUT THE BURIED BLOCK MAY BE USED AS PART OF THE TRENCH DEPTH PROVIDED THE SOIL WITHIN 5'-0' OF EACH SIDE OF THE BLOCK IS COMPACTED TO 90 PERCENT. THE OVERALL WALL HEIGHT IS PROTO-II (5) AND TABS COLLAPSED TO ACHIEVE TENSION. REGARDLESS OF WHETHER A COURSE IS BURIED. NO SCALE B. DTI IS ONE OF TWO APPROVED METHODS OF TENSIONING. OTHER OPTION OF TENSIONING IS TORQUE TO 55 FT/LBS USING A CALIBRATED (3) PLAN VIEW NOTES: TORQUE WRENCH D11 MUST STILL BE PLACED (4) (1) ON ROD IF USING TORQUE WRENCH METHOD. 1. FILL CAP BLOCK WITH MORTAR. (2 SEE GENERAL NOTE 17. ) IMMEDIATELY "FLIP" ONTO ROD. C. SPECIAL DEPUTY INSPECTOR WILL PERFORM A 2. CAP BLOCK OF SUFFICIENT SIZE I VISUAL INSPECTION WHEN USING THE D11 METHOD TO COVER PLATE AND ROD. TO CONFIRM THE DTI IS COLLAPSED WITH NO, 3. STEEL PLATE SIZES: LIGHT LEAKS BETWEEN THE TABS AND BOTTOM OF A\. 4" PROTO 11: 1/4" x 3" x 6" TORQUEDNUT. IF USING WRENCH DEPUTY INSPECTORWILL CONFIRM WALL S B. 6" PROTO II: 1/4" x 4 1/2" x 6" TORQUED TO 55 FT/LBS AND VISUAL INSPECTION C. 6" SLUMP PROTO 11: 1/4" x 4" x 6" SECTION OF DTI IS NOT REQUIRED. D. 8 PROTO II: 1/4" x 6 1/2" x 8" X D. INSTALLER MUST HAVE SPECIAL DEPUTY STEEL PLATES TO BE PLACED AT INSPECTION PERFORMED BY ONE OF THESE TWVO THE EDGE OF THE CELL SO THAT METHOD, BY A SPECIAL DEPUTY INSPECTOR. INSPECTOR TO PROVIDE A COMPLETED REPORT TO THE PLATE BEARS FULLY ON LISTED PARTIES. 4 THREE SIDES. CONTINUOUS HORIZONTAL JOINT I „ 1 DTI INDICATOR (DIRECT TENSION INDICATOR) REINFORCING PER NOTE #12. 5. CENTER WEB BELOW. NO SCALE NOTES: 3 1. PROTO II WALL. 2. 3" MORTAR COVER AROUND (1) 2 COUPLER AND/OR POST TENSIONED ROD FOR CORROSION PROTECTION. 3. 7/16" DIA FULL HEIGHT POST TENSIONED RODS WITH 3" HOOKS. ROLL THREADS AT TOP FOR NUT ATTACHMENT. NO VOIDS OR JUNCTION OF POST TENSION ROD AND REINF. BARS ALLOWED. PROVIDE CONSOLIDATION OF CONCRETE VIA VIBRATION, RODDING OR OTHER APPROPRIATE MEANS. 4. THICKEN FOOTING TO PROVIDE 3" MIN. COVER AS REQUIRED AROUND ANCHOR BOLT. 5. SEE SCHEDULE AND OTHER DETAILS. - G �(3) rr M U FOOTING ELEVATION AT POST TENSIONED ROD NO SCALE NO SCALE NOTES: 1. 4" NOMINAL (3 5/8" ACTUAL OR 6" NOMINAL 5 5/8" ACTUAL OR 8" NOMINAL �7 5/8" ACTUAL MASONRY. 2. HORIZONTAL JOINT REINF - SEE NOTE #12. v(1)v 3. #4 CONTINUOUS AT 4" & 6" PROTO II '7 #5 CONTINUOUS AT 8" PROTO II, 4. CONCRETE SETTING PAD. NO VOIDS OR (2) HONEYCOMBING OF CONCRETE AT JUNCTION _ OF POST TENSION ROD AND REINF. BARS ALLOWED. PROVIDE CONSOLIDATION OF _ CONCRETE VIA VIBRATION, RODDING OR OTHER APPROPRIATE MEANS. = 5. DASHED LINE INDICATES LINE OF DIP FOOTING ~ OR LINE OF CONT TRENCH FOOTING. 6. DEPTH OF CONTINUOUS TRENCH FOOTING. o_ c _ (2) 7. * 8" AT 4" AND 6" PROTO IL N o- _ 7A. FOR 8" WIDE WALLS USE 10" WIDE FLANGE, Q o 6"DEEP AT TOP OF FOOTING. N 8. 3" MORTAR COVER AROUND COUPLER rl� :� AND/OR POST TENSIONED ROD FOR CORROSION PROTECTION AT FIRST COURSE. N fr 9. VERTICAL REINFORCING AT TRENCH, AND U_ (8) (3) DIP FOOTINGS FOR WALLS OVER 6'-0" co(7A) HIGH. USE #4 x AT THE 6" AS ER STRAIGHT "J" OR "L" OK �_ REQUIRED OF \ (11) EACH DIP FOOTING AT DIP FOOTING DESIGN. i (4) REBAR SPACING IN TRENCH FOOTING FOR WALLS 6'-8" TO 8'-0" SHALL MATCH `o �`' \ (5)SPACING OF DIP FOOTINGS. ABOVE 8'-0l" -H i(10) AND WHERE DIP FOOTING SPACING NOT (9) AVAILABLE, SPACE VERTS AT 24" O.C. MAX. 10. A CONTRACTOR OPTION IS TO STAB THE #4 VERTICAL REBAR DOWN INTO THE DIP, PIER "(7) OR CONTINUOUS TRENCH FOOTING AND EXTEND IT +/-8" INTO THE FIRST COURSE OF BLOCK. 11. 2" SOIL MIN OVER FOOTING. 3 TYPICAL WALL SECTION AT DIP FOOTING AND TRENCH FOOLING NO SCALE PROTO II FENCE WALL SCHEDULE - CALIFORNIA 2010 CSC AND 2009 IBC EXPLANATION OF WIND LOAD DESIGNATIONS: ASCE 7-05I = 0.87 (CATEGORY I TABLE 6-1) qz = 0.00256 x Kz x Kzt x Kd x V2 x I (EQ. 6-15) F = qz x G x Cf x Af (EON 6-28) Kz = 0.57 EXP B, 0.85 EXP C (TABLE 6-3) G = 0.85 (RIGID STRUCTURE SEC 6.5.8) Kzt = 1.0 FOR H S 15'-0' (SECTION 6.5.7.1 15) *Cf = 1.3 x 1.1 (FOR S/H = 1 AND B/S 2 10) Kd = 0.85 (SIMILAR TO SOLID SIGN, TABLE 6-4) As = ASSUME 1 SQUARE FOOT. V = VELOCITY 3 SECOND WIND GUST * 1.1 MULTIPLIER USED TO ADJUST FOR OBLIQUE ADJUSTMENT FACTOR PER FIGURE 6-20 FOOTNOTE 3. CITY OF BUILDING S,4.1 _i:)T. A FOR NS N DAT 0//��_Mktc� NOTES: 1. FOOTING DESIGN ALLOWABLES: 1000 PSF BEARING, 200 PSF/FT LATERAL. 2. MAXIMUM HEIGHT FOR 4' PROTO II = 6'4': MAX. HEIGHT FOR 6' PROTO II = 10'-0'. MAX. HEIGHT FOR 8' PROTO II = 13'-4' COMBINATION WALLS MAY BE USED. 3. MAXIMUM DIP FOOTING SPACING = 16'-0': MINIMUM SPACING = 3'-40. TOLERANCE IS 12"t BUT THE NUMBER OF DIP FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL. 4. POST TENSION ROD IS INDEPENDENT OF DIP OR PIER SPACING. 5. POST TENSION ROD SPACING TOLERANCE IS t8' BUT THE NUMBER OF RODS FOR A GIVEN LENGTH REMAIN THE SAME. 6. 13'0 x 3'-9' DEEP CIRCULAR PIER FOOTING WITH 1 #4 VERT, MAY BE USED IN LIEU OF DIP f SPACING AND SETTING PAD TO REMAIN THE SAME. WIND WALL 4' PROTO II 6' PROTO II 8' PROTO II DIP/PIER CONTINUOUS INC. FORCE HEIGHT POST TENSION POST TENSION POST TENSION FOOTING TRENCH FOOTING (480) 774-1701 FAX www.ctsaz.com ROD SPACING ON CENTER ROD SPACING ON CENTER ROD SPACING ON CENTER ON CENTER SPACING, SEE DEPTH ** SEE DETAIL 3 w EXP..1 131113 M � OF AONI J DETAIL 4 FOR FOR SECTION W Q U U z LTJ O DIP FOOTING I Ui O PROFILE, SEE Jw J J �V) �O �z v) >_Z o LJ f Co �Ld U 1 Ld U DETAIL 3 FOR Cr) �M �1 N o Z w O war�rn w > O ~ Q� cn Q L.L_j ..� UUZO)v O C) w�Q x_ CL m O � < X M U SECTION J OQ 00 cn z 14.1 PSF 3'-4' 8'-0' 8'-0' 8'-0' 16'-0' 17' U.S. PATENTED 7,454,870 85 MPH 4'-0' 694' 8'-0' 8'4' 14'-0' 19' DRAWN: ExP C 44 694884 8 -0 12' -On 21 51-4' 4'-0' 8'4' 8'-0' 12'-0' 23' 6'4' 31-4' 6'-0' 6'-0' 11'"6' 24' . 6 -8 2 -8 6-0 69-Ow91-40 26' 79-4' - 294' 4'4' 714' 27' 8'-0' - 2'-0' 3'-4' 61-4' 29' 8'4' - 11-4' 2'-8' 5'4' 30' * 9'-4' _ - 2'-0' - 32' * SEE GENERAL NOTE 18. ** TRENCH FOOTING DEPTH ADJUSTMENT (AT CONTRACTOR'S OPTION) : AT THE CONTRACTOR'S OPTION, UP TO ONE COURSE OF MASONRY MAY BE BURIED BELOW GRADE. THE BURIED BLOCK MAY BE USED AS PART OF THE TRENCH DEPTH PROVIDED THE SOIL WITHIN 5'-0' OF EACH SIDE OF THE BLOCK IS COMPACTED TO 90 PERCENT. THE OVERALL WALL HEIGHT IS DEFINED AS SHOWN IN DETAIL 3, FROM THE TOP OF THE FOOTING TO THE TOP OF THE WALL REGARDLESS OF WHETHER A COURSE IS BURIED. CITY OF BUILDING S,4.1 _i:)T. A FOR NS N DAT 0//��_Mktc� NOTES: 1. FOOTING DESIGN ALLOWABLES: 1000 PSF BEARING, 200 PSF/FT LATERAL. 2. MAXIMUM HEIGHT FOR 4' PROTO II = 6'4': MAX. HEIGHT FOR 6' PROTO II = 10'-0'. MAX. HEIGHT FOR 8' PROTO II = 13'-4' COMBINATION WALLS MAY BE USED. 3. MAXIMUM DIP FOOTING SPACING = 16'-0': MINIMUM SPACING = 3'-40. TOLERANCE IS 12"t BUT THE NUMBER OF DIP FOOTINGS MUST REMAIN THE SAME FOR A GIVEN LENGTH OF WALL. 4. POST TENSION ROD IS INDEPENDENT OF DIP OR PIER SPACING. 5. POST TENSION ROD SPACING TOLERANCE IS t8' BUT THE NUMBER OF RODS FOR A GIVEN LENGTH REMAIN THE SAME. 6. 13'0 x 3'-9' DEEP CIRCULAR PIER FOOTING WITH 1 #4 VERT, MAY BE USED IN LIEU OF DIP f SPACING AND SETTING PAD TO REMAIN THE SAME. r - 2 CARUSO TU RLEY SCOTT INC. consulting structural engineers 1215 W. Rio Salado Pkwy Suite 200 Tempe, Arizona 85281 (480) 774-1700 (480) 774-1701 FAX www.ctsaz.com F�pF SS/ q� Q KI S 4 55 z w EXP..1 131113 M � OF AONI J J Q Co W Q U U z LTJ O LL_ 0 I Ui O Jw J J �V) �O �z v) >_Z o LJ f Co �Ld U 1 Ld U O �� w o o�o�� p a Cr) �M �1 N o Z w O war�rn w > O ~ Q� cn Q L.L_j ..� UUZO)v O C) w�Q x_ CL m O � < X M U • w = J J OQ 00 cn z LJ zm CQ U.S. PATENTED 5,794,921 t° Z U.S. PATENTED 6,431,797 " >- U.S. PATENTED 6,632,048 < U.S. PATENTED 7,188,453 U.S. PATENTED 7,454,870 U.S. PATENTED 7,461,487 TRACKING NUMBERS: 08-115-6100 08-115-6200 10-115-6900 11-115-7400 JOB NUMBER: DRAWN: ENGINEER: CHECKED: SCALE: AS NOTED DATE: