BSOL2014-002978-495 CALLE TAMPICO T4/ D
LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BSOL2014-0029 Owner:
Property Address:
81540 BAFFIN AVE JAMES LIPPMAN
APN:
767710036 317 N ROCKINGHAM
Application Description:
17.01kW PV SYSTEM - (54) 315W PANELS/(3) INVERTER+125A SUB LOS ANGELES, CA 0
Property Zoning:
Application Valuation:
$63,000.00
Applicant:
PLANET SOLAR INCORPORATED
73820 DINAH SHORE
PALM DESERT, CA
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. C46 License No.: 938313
Date:.- b Contractor:
OWNER -BUILDER DECLARATION f
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9,(commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
I ) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_ ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
I ) I am exempt under Sec. . B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Contractor:
PLANET SOLAR I NCORPORA'
719 E HALEY STREET
SANTA BARBARA, CA 93103.
(805)692-2700
Llc. No.: 938313
Date: 6/4/2015
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the wor ttich this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Polity Number: _
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become sub' to the
workers' compensation provisions of Section 3700 of the Labor Co all forthwith
comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to buildin
construction, and hereby authorize representatives of this city to enter upon the o e
mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
J
DESCRIPTION.',.
FINANCIAL INFORMATION
ACCOUNT `
QTY a AMOUNT: ,.
PAID
PAID DATE
HOURLY CHARGE - BLDG CITY STAFF
101-0000-42600
0.8
$116.00
$0.00
PAID BY
'METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION y
ACCOUNT
QTY
-.AMOUNT'
PAID
PAID DATE
HOURLY CHARGE -BLDG CITY STAFF
101-0000-42600
0.75
$108.75
$0.00
PAID BY
: - ,METHOD ;
RECEIPT #
CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $224.75 $0.00
DESCRIPTION ..
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$3.00
$0.00
PAID BY j ` _'
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $3.00 $0.00
DESCRIPTION'
ACCOUNTS_
QTY,
AMOUNT
PAID`
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$0.00
}PAID BY s
METHOD
RECEIPT #
CHECK #
CLTD BY
:DESCRIPTION , , -
, . ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
N PAID:BY : - . ` :
METHOD, ..
- . RECEIPT .#
CHECK # .
CLTD BY.
DESCRIPTION - :
ACCOUNT .
QTY-
' AMOUNT
PAID
;PAID DATE
PV SYSTEM - MISC EQUIPMENT
101-0000-42403
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION ...
ACCOUNT
QTY
AMOUNT
_ PAID
PAID DATE
PV SYSTEM - MISC EQUIPMENT PC,
101-0000-42600
0
$24.17
$0.00
- 'PAID BY' --.� ,.
- METHOD -
RECEIPT #
CHECK #
CLTD BY
Total Paid for ELECTRICAL: $96.68 $0.00
''DESCRIPTION'. ''• i
ACCOUNT t
QTY
�'
n-AMOUNT
- - PAID,
PAID DATE
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
PAID BY,
METHOD",-
RECEIPT#
CHECK#
CLTD BY,
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:• •-
-- - - - , - -- . RMIT NUMB PEER
_
.Perniit.Details
' City of La=Quinta �, r. 2 4MC
��. �BSO 0 029
Description: 17.01kW PV SYSTEM - (54) 315W PANELS/(3) INVERTER+125A SUB
Type: SOLAR Subtype: Status: APPROVED Applied: 10/14/2014 SKH
Parcel No: 767710036 Site Address: 81540 BAFFIN AVE LA QUINTA,CA 92253 Approved: 6/3/2015 JFU
Subdivision: PM 36300 Block: Lot: 2 Issued: 232
' 1
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled:
Valuation: $63,000.00 Occupancy Type: Construction Type: Expired: -
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 17.01 kW SOLAR ARRAY - (54) 315W SOLAR WORLD SW315 MONO PANELS W/ (3) SMA SB6000TL-22 INVERTERS + 125A SUBPANEL
[972SF] 2013 CALIFORNIA ELECTRICAL CODE. "
t,
' JJ Applied to Approved,, ' ' s
ADDITIONAL
CHRONOLOGY
'CHRONOLOGY TYPE-.'
STAFF NAME .. t ;;` 'ACTION :DATE COMPLETION DATE; ,.
a" NOTES �..`
PLAN CHECK PICKED UP
KAY HENSEL
2/20/2015
2/20/2015
PLAN CHECK CORRECTIONS PICKED UP
PLAN CHECK PICKED UP
MARY FASANO
5/27/2015
5/27/2015
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
4/8/2015
4/8/2015
PLAN CHECK PICKED UP BY STEVE PYLE.
PLAN CHECK SUBMITTAL•
MARY FASANO
6/1/2015
6/1/2015
RECEIVED
RESUBMITTAL
PHILIP JUAREZ
2/6/2015
2/6/2015
RESUBMITTAL
PHILIP JUAREZ.
4/2/2015
4/2/2015
plans resubmitted
SPOKE WITH CHRISTIAN FROM PLANET SOLAR VIA
TELEPHONE CALL
JAKE FUSON
11/14/2014
11/14/2014
TELEPHONE, NOTIFYING HIM 1ST REVIEW WAS COMPLETE,
REVISIONS WERE REQUIRED, AND PLANS/CORRECTION LIST
WERE READY TO BE PICKED UP
Printed: Thursday, June 04, 2015 3:50:44 PM - 1 of,4 CR SYSTEMS
OF T
NOTIFIED STEVE W/ PLANET SOLAR INC THAT HIS PLAN
TELEPHONE CALL
JAKE FUSON
2/18/2015
2/18/2015
REVIEW WAS COMPLETE AND REVISIONS WERE REQUIRED.
NOTIFIED STEVE PYLE W/ PLANET SOLAR THAT PLAN REVIEW
TELEPHONE CALL
JAKE FUSON
4/8/2015
.4/8/2015
WAS COMPLETE AND REVISIONS WERE REQUIRED.
NOT STEVE PYLE W/ PLANET SOLAR THAT PLANS REVIEW
TELEPHONE CALL
JAKE FUSON
5/26/2015
5/26/2015
WAS COMPLETE AND REVISIONS WERE REQUIRED.
NOTIFIED JONATHAN AT PLANET SOLAR THAT PLANS WERE
TELEPHONE CALL
JAKE FUSON
6/3/2015
6/3/2015
APPROVED AND PERMIT WAS READY TO ISSUE.
CONDITIONS
CONTACTS
NAME•TYPE ,
NAME -
ADDRESS3
CITY
STATE
ZIP- .PHONE' FAX EMAIL
APPLICANT
PLANET SOLAR INCORPORATED
73820 DINAH SHORE PALM DESERT CA
CONTRACTOR
PLANET SOLAR INCORPORATED
719 E HALEY STREET SANTA
CA
93103
BARBARA
OWNER
JAMES LIPPMAN
317 N ROCKINGHAM LOS ANGELES CA
0
FINANCIAL••
•
CLTD
DESCRIPTION
ACCOUNT ,
QTY
AMOUNT
PAID ; •
PAID DATE
RECEIPT #
CHECK #
METHOD F
PAID BY - :
-BY
f .
HOURLY CHARGE -
101-0000-42600
0.8
$116.00
$0.00
BLDG CITY STAFF
HOURLY CHARGE -
101-0000-42600
0.75
$108.75
$0.00
BLDG CITY STAFF
Total Paid forBLDG CITY STAFF - PER HOUR: $224.75
$0.00
BSAS SB1473 FEE
101-0000-20306
0
$3.00
$0.00
Total Paid forBUILDING STANDARDS ADMINISTRATION
$3.00
$0.00
BSA:
PV SYSTEM - ARRAY,
101-0000-42403
0
$24.17
$0.00
FIRST 20
Printed: Thursday, June 04, 2015 3:50:44 PM 2 of 4
EYCF SYSTEMS
. ~ DESCRIPTION'
ACCOUNT
QTY `
AMOUNT,,,
PAID 1`
PAID DATE
`RECEIPT,#.
CHECK#
METHOD
-x ',.,PAID -BY, "
CLTD
• BY.
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$0.00
FIRST 20 PC
PV SYSTEM - MISC
101-0000-42403
0
$24.17
$0.00
EQUIPMENT
PV SYSTEM - MISC
101-0000-42600
0
$24.17
$0.00
EQUIPMENT PC
Total Paid for ELECTRICAL: $96.68 $0.00
PERMIT ISSUANCE
101-0000-42404
0
$91.85
$0.00
Total Paid forPERMIT ISSUANCE: $91.85 $0.00
TOTALS:•0
PARENT PROJECTS
-+ REVIEW TYPE `' REVIEWER ._
REVIEWS
SENT DATE` DUE DATE . RETURNED• F STATUS . �� REMARKS ` t ;,NOTES'
DATE .. _ ".-s.
NON-STRUCTURAL
JAKE FUSON
10/13/2014
10/20/2014
11/14/2014
REVISIONS REQUIRED
SEE ATTACHED CORRECTION LIST
APPLICANT INCORRECTLY SUBMITTED PLANS FOR
A HOUSE OUTSIDE CITY LIMITS. APPLICANT WAS
NON-STRUCTURAL
JAKE FUSON
2/6/2015
2/13/2015
2/11/2015
PENDING DOCUMENTS
NOTIFIED, AND WAS ASKED TO RE -SUBMIT THE
CORRECT PLAN.
NON-STRUCTURAL
JAKE FUSON
2/11/2015
2/18/2015
2/18/2015
REVISIONS REQUIRED
SEE ATTACHED REVIEW.
NON-STRUCTURAL
JAKE FUSON
4/2/2015
4/9/2015
4/8/2015
REVISIONS REQUIRED
SEE 3RD REVIEW.
NON-STRUCTURAL-
JAKE FUSON
5/18/2015
5/26/201S
5/26/2015
REVISIONS REQUIRED
1 WK
Printed: Thursday, June 04, 2015 3:50:44 PM 3 of 4 C srsreMs
INON-STRUCTURAL' I APPROVED-
- I JAKE FUSON 1 6/1/2015 1 6/8/2015 1 6/3/2015
WIRING IN WET LOCATIONS MUST BE APPROVED
FOR WET USE LOCATIONS. FUSIBLE J-BOXES MUST
I I CONTAIN 15 AMP FUSES.
BOND INFORMATION
74
v , ' -!',,'lPA NAME,�.�,,.' SUBDI 1gENABL
-Aitic�Wen�typj4 ...OWNEFt'-:.:fbESCRlPil0 fH ETRAkl'
'CREATED
DOC
2/18/2015
JAKEFUSON
SOLAR 2ND REVIEW
SOLAR iND REVIEW.pdf
0
DOC
2/18/2015
JAKEFUSON
SOLAR 1ST REVIEW
SOLAR 1ST REVIEW.pdf
0
DOC
4/8/2015
JAKEFUSON
SOLAR 3RD REVIEW
SOLAR 3RD REVIEW.pdf
0
SOLAR 3RD REVIEW -
SOLAR 3RD REVIEW -
0
DOC
4/8/2015
JAKEFUSON
REDLINES
REDLINES.pdf
DOC
5/26/2015
JAKEFUSON
SOLAR 4TH.REVIEW
81540 Baffin - 4th.pdf
0
17.01 kW DC PV SYSTEM
AZIMUTH: 180'
PANEL TILT: 3'
(54) SOLAR WORLD MODULES: 315W
PV MODEL#: SW315 MONO
MODULE DIM: 78.15" X 38.98"
MODULE WEIGHT: 49.6 Ibs
INVERTER MODEL#:
(03) SMA AMERICA, SB6000TL-US-22
PV STRUCTURE:
SOLAR WEDGE ATTACHMENTS W/
PRO SOLAR SUPPORT RAIL
ROOF TYPE: FLAT
NUMBER OF STORIES: 02
ROOF TILT: 0'
ROOF FRAMING: 2"x4"
ROOF RAFTERS: 16" O.C. SPACING
STRUCTURE TYPE: SFR
NUMBER OF ROOFS UTILIZED: 01
(2) STRINGS OF 09 MODULES TO EACH
INVERTER, x (3) INVERTERS
PV ARRAYS
ROOF ACCESS AS
PER SECTION R331.4.1
OF 2013 CBC
Photovoltaic equipment and systems and
all associated wiring and interconnections
shall be installed only by qualified persons.
• ,, f f
4 A.
THIS HOME IS NEW CONSTRUCTION
JUNCTION BOXES
CONDUITS 3/4" EMT L-�-3'
ON ROOF/UNDER EAVE/
IN ATTIC
TRENCHING
PVC + 1" EMT
Photovoltaic system conductors shall be identified o d grouped. The
means of identification shall be permitted by separa a color coding,
marking tape, tagging, or other approved means. Tie means of
grouping shall be wire ties or similar means at least once, and then
at intervals not to exceed six (6) feet.
PHOTOVOLTAIC INSTALLATION PLAN
SCALE: 1 "=25'
GARAGE #1
GARAGE #2
FIRE CLEARANCES ADHERED AS
PER SECTION R331.4.2
OF 2013 CBC
3'-0" FROM RIDGE & EDGE
1'-6" FROM VALLEYS
CITY OF LA QUINTA
BUILDD NG & SAFETY DEPT.
MIPROVED
17011 CONSTRUCTION
MAIN SERVICE
PANEL (INSIDE)
800A, 208V
3 PHASE
PV SUBPANEL,
125A, 208V AC DISCONNECT
200A
TRENCHING
PVC + 1" EMT
INVERTERS
SB6000TL-US
VICINITY MAP
a`
b. to
iA a
°s
PROJECT LOCATION '
SCOPE OF WORK
THIS PROJECT CONSISTS OF THE INSTALLATION OF (63)
PHOTOVOLTAIC MODULES AND (03) UTILITY INTERACTIVE INVERTERS.
PV MODULES WILL BE MOUNTED TO AN EXISTING RESIDENTIAL FLAT
ROOFTOP USING SOLAR WEDGE ATTACHMENTS AND PRO SOLAR
SUPPORT RAIL. SYSTEM WILL BE 3 PHASE POWER AT 208V.
THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND
11OMPH WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS.
REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED
INFORMATION AND WATER PROOFING SPECIFICATIONS.
SHEET INDEX
SHEET NO. INDEX NO, DESCRIPTION:
01 T-1 TITLE SHEET
02 M-1 PHOTOVOLTAIC EQUIPMENT PLAN
03 M-2 STRUCTURAL CALCULATIONS
04 E-1 SINGLE LINE DIAGRAM
05 D-1 PHOTOVOLTAIC MODULE DATA SHEET
06 D-2 INVERTER DATA SHEET - S86000TL-US-22
07 D-3 ATTACHMENT DATA SHEET
08 D-4 RAIL DATA SHEET
09 L-1 WARNING PLACARDS
PROJECT JURISDICTION
PREPARED FOR:
CITY OF COUNTY: CITY OF LA QUINTA
ADDRESS: 78-495 CALLE TAMPICO
CITY, STATE,ZIP LA QUINTA, CA, 92253
PH: 760-777-7125
t
W
V)
W
I—
w
U
z
w
N
w
ofwUj
Z D N
QW�
�>
aaa�
�zU -
oal¢-"'
zmz(5
J O
�_�
W N .J
a
w
N
CIJ
O) m
JW
M
OQ(<'-
0 z:
NVHUd
W = W M
ZQcn—O
Q Z W r7 (D
J 0 00 r
IL
o�rn
N J
rna0
n J
CODE COMPLIANCE ' 11
ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA 5/29/15
BUILDING, RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERGI"� DRAWN BY: BPM
AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. APN: 767-710-03-E
LOT: 1.86 acres
DWELLING SFR, ---sq
N
PV SYSTEM SPECIFICATIONS T-1
SOLAR WORLD 54 SB6000TL-US-22 03 SOLAR WEDGE ATT 3. 180' 17.
SW315 MONO I I I PRO SOLAR RAIL
MCDAE OTY, I NVERTFR I OTY. I RA"G mT AZW oC
I�
1
Assembly of the SolarWedge
PV MOUNT ATTACHED W/ SOLAR WEDGE
~
PRO
E� Components of theSolarWedge;
TOTDATAENTS SH ETSDFOR WINDLAR ANDRAIL VERTICALEM. FORCEFER
M
y� system easily integrate with the
new XD support rail,
DESIGN CHARACTERISTICS
..
AlP.9 NU'.
O' FLAT ROOF SURFACE
r
2X4 WOOD TRUSS
016" O.C.
�({� '�� � ,
- 30
9'-0.
FROM EAVE
TO GROUND
- Rutty Ass.,^n,bled
CONNECTION DETAIL N.T.S.
SECTION PLAN N.T.S.
AERIAL VIEW
ROOF LOAD CALCULATION
CLASS 1 - DIVISION 1 METALLIC CONDUIT W/NO JOINTS
ROOF: 54 PANELS
PENETRATION SPACING: 64" MAX
HOUSE MAIN GARAGE#2
Ld
U
PV AREA SINGLE MODULE: 21.15 SQ. FT.
Z
PV AREA TOTAL: 1,142.1 SQ. FT. FIRE CLEARANCES ADHERED AS
N SUBPANEL
()
(N) AC UTILITY 200A
I
0
w
PV PANEL WEIGHT = 49.6 Ibs PER SECTION R331.4.2
MOUNTING HARDWARE WEIGHT=10 Ibs/panel OF 2013 CBC
DISCONNECT
200A 07E
X Uj ui
N
ENTIRE WEIGHT ON ROOF: 35r_Qrr 3'-0" FROM RIDGE & EDGE
(E) MAIN
z
>�r�
(49.6 Ibs, panels)x(54)+ 1'-6" FROM VALLEYS
SERVICE
Z
a ¢ Q o-
(10 Ibs, structure)x(54)= 3218.4 Ibs
PANEL, 800A
[2678.4+540] 3r-3rr 5r_4a
CW
G
v
Q�Q�
O
u.�
0¢E—"'
zmz�
3218.4 Ibs/1,142.1 sq.ft.= 2.82 Ibs/sgft
ATHENG
z o
(Y
u2 ¢
U-1W
ao -j
32rwG
—
TO ARRAYS
j 6r_6rr
f
TRENCHING
- - -- —
> - o
o
MAIN SERVICE ELEVATION
i
, &
H
GENERAL NOTES:
O) m
Q X¢
., � � o
JUNCTION BOXES — —
1. CONDUIT RUNS ARE DIAGRAMMATIC SUBJECT TO FIELD CONDITIONS
o 0 (3 ¢ 5 1
AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET
N 0 - I
1r_1u
NEC REQUIREMENTS.
~ = Of 1
UJ
z to
2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL
z �r7o
¢_wtp
LOCAL BUILDING AND ELECTRICAL CODES.
a 0 0 to r 1
— - — — — ---
3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC
a'
SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO
oD n v i
RACKING DATA311EET.
r-
4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR
�— ! L NilREADING
AND UNDERSTANDING THE SECTION OF THE INVERTERS
Z
OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE
I �
SAFETY AND PROPER INSTALLATION.
in
}` 3r
5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL
5/15/15
3/4" E.M.T. ON I
FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED.
DRAWN BY: BPM
ROOF/UNDER EAVE x1 r_4a
1
6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE.
IN ATTIC PANEL RAILS
7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY
ATTACH MODULES TO
PLUMBING, MECHANICAL OR BUILDING ROOF VENTS.
APN:767-710-03-6
STRUCTURE PER DETAILS EXISTING 2X4
AND DATA SHEET RAFTERS
8. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHT RESISTANT.
LOT: 1.86 acres
GBL GROUNDING LUGS USED ® 16" O.C.
9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE
DWELLING: SFR, ---s ft
PER 2013 CEC 690.43,
BATTERIES
UL 2703 LISTED TRENCHING TO: N
M-1
SB6000TL INVERTERS
PV SYSTEM SPECIFICATIONS
1
PV LAYOUT PLAN PV SUBPANEL,125A ® 208V
1 MAIN SERVICE PANEL
SOLAR WORLD
SW315 MONO
54
SB6000TL-US-22
3
OLAR WEDGE ATT
PRO SOLAR RAIL
3.
180'
17.01kW
SCALE: 1/10" = 1'-0" AC DISCONNECT
uODME
arr.
e+icrsrea
atr.
rsAaa+c
mt
A2pp1rH
vats N
(sm)
2
— ENLARGED PARTIAL ROOF PLAN DETAIL
F
V 9 N C I & A S S O C I A T E S
' Cuvctural f(ubintwrs `
CUBM
Pialw ianal Selal Produss, Inc .
r 1S51 S. Hcse Ave.. 0)ri;r d, CA 03033
'rol: 805-4884700
+!� Subject: Static load test results for the following:
faae
to
CUraknW Sznu
�hlovrd'ngSyem
Lnm;df04
Oh/R
(In •M•
RodTrac•
65
125
+I1I TEST SF.i iP (as s:.o'rm In Cached dlaerlft dot -all): Intee I110OU10 J, 03 sac•=?ed bbive, rare 13oM rd 13 -xIS'x2S'
t ,1 ss to Ski .21 Saidf PfaiAJcis (PSP) patrntni Rdof .am swoon' faits tThe 1 mr11700 v4 of 5/16' S's liessGhee Sir -el (55) MtIAI
.:.._... .-. .\. u �•... L
..�
SS Iu+;k n�tl>rJls and propttldbry PSP aluminum clump; FPn.I Inserts. rt+o ItaclrwN rrrylaert rail was attaeJtrxl to the PSP Modu:a _ �
e� Roctrroc muc:ual adach nient deY,ce wkh 3/6 SS hterdvrare at row ahechment po.nts. The setup was attached to 2'.t6'
wooJen rafters usire 5/16' F 3,V2' SS In8 lulty. The at1;JrJJCtsnt r*5n4 mtie te-d of 48' fmllt to rear with structural aahy tam �
ri attachnierts Spaced 7 on center. -•-•-•
1 l - I _.+ - j _ TF-ST I'MrADURi (as fn attached drawing wnvey co
-t--- ` - ( wlr�detail):itrYtstsetupwasioplo]dedtoSOlu/1F.ThesetupreraJJted
�,.._.. �. �...._�_ � ) �`-•- Pro501ar S01ar1Ned standoff r+,' lead^_d or an dpprcximate porio] of 30 ntfnutes. T�e rtwtimum deflection and any *Igns of pennancht dclomla:VxJ wets
:< tecorded. The test wtup w'ar then inverted
boded to !Atlulate the tplift eoiididor. The tit set up was re loaded ;] 5o Total m `dtde (45 ftfs o . � I SD Psf
4 (spaced up to 72" O.C.) lb/ft'-'. The setup ramalnad bre ad to: on approzhmitie poled of 30 minutes. The maximum deflection and any signs of and fall 12lbs ea.) wet ttt• 159 lbs it
a. yerm3ne it dafounallon were recorded. Number of attachments: 4 Cie _
T13rRESULTS: %Velght I atuchment point 40 Ills
f� SOLAR WORLD SUNM01A1LE ° The maximum trp load tie 11:Y:t]Un was recorded at 0.313'. atth it* peimanent dotormnlien. Area: 54 R2
1- PLUS Sa270 (270L'Lf) Tbo maximum uptdt den -don was secorded at 0.250', w ah no rrmnan: delormVen, f --- _ —•
Existing 2' r. 4" rafter � Distributed rJeight 2.95 ib! fty (�
(spaced !n 16" O.C.) 6S.94 x 39.41 1, 1.22 in
(1675 x 1001 x 31 mm) Th--s lfoeumont eortll'+e; tl;e Roofimcs mounUnp system used with the nit4uLas• as spetil:W above, withstands a 50 fV(t=
f biailc prrxsura toad, aUut�tlenl to a wlfxt bCaed or ap7fatLltair.iy 124 myh'-. The nicuwlrg slstena performed os exnecte
46.7 Ibs 21.2 ) (' 5116' Statn'ess
k9 r'. Top load Deflection: 0:313"
I _ Siut4 Ilex bolt
:.710 Ib011
/ - SOLAR MODULE MOUNTING DETAIL tamer, R. Vinci. S.E. ptf �f
/ r>r18- Stemless S:acl
I,._., ,��,...,.,- - .�.,, , •� Tl-ta nna reCrnt reccffrcfdixx Mat %radt.lisPte:ea has rstwCv am-tesuet indmu+axln t•+olewt Too rnW!s ult es�•�--""—_ Lack Washer
i•—I�_� t_' 1
Ipad tl:l rCQKt nersol dalletJRi.aluxO and MOaf'IalJDf aCCer✓.rN as {f+a Welt dartl dly Nstnar,lndda NPYn..ndl14(e'nl. Md&Aara6flbD y �$ TM1>.. •iy •.^ _
not Oaf!dlo6 MaiabYYr.dMrdj the:l.•tammn;M+t:Ysa:nh Vat mca as Le4V.lga'nffea rlt (.nhYL t'xtCft - Ahltnlnum Prosolar t
roe:-:utJlew't9rl Sn s',..h.Mt Urmxho-nJl:.svJ y�9'r"1�.� In.�ockonmc.•rarlt.�-�.— tnter•rtoduWClamp
l H? ina ys:ern,ePr.�wrv_////'���-d?.41 -,1
JP
1n Crfe".1he'R'gnrxY' Heft m eet.I. If W.CtJM ar (90-0-f
A (tear we af led noolaulm±nralHu f—I Fla L lift Deflection: 0
"Iel'fttl afolea Lotrr Plod. Pit4W0Aal'rrl Ur, lnGu:4Mr Ot'eil� {J 1 f- i �� Aluminum Fro Solar p
•l 5wctual or,amrox:rL lKDolt ar�cr+•nx+;t nrl.'SrtP40 i,aJeed i IZtl11 nut
- Pf1(JTOVOLTAIC MODULES k N<•s lw:m 3/lofnterefo.q;Sth*,Mf�r•�/.j UM0t b
t ;rl ,«na:o a L1e• rrwl hda.a: w,afaxwstn Wr f�ma . _ ~`"'�2• t 2' A'r,Jm'rvum ProSOld_
• MrtrGn bPuuroaucsk'rx1+:11menthaurderoa:n ehLe prof memar. n:Ule rqul. fr.0 b- t 3
IT
Rvorl race Suppoit Rail
ae-ureA'addxn b tat ruoi'vrw'wa—yrecun ul 44^,Za to al r•MWn: P,:W nl alt rvw r"'Mny
16• Stainless Steel Flex
{ �--��- &lit and FlatlNa:Jler s�
t "•+��j Inn W. all rlotulNtl.:slo.Tnbn d. bJ to lose baJru r.e+l'Ifl niC ld tM •nS'sm Ul I. , !!
'.�,, m,*Mh•a4,ylr v aJ.naea000ut Imlarml', a r MunxinumPra''narvtontad
,•. :Ca•x1aK Ml :aNxtn'aredJblafLsu4a.+iv_a7starzM`."ana'oanJacui;lmra Ihr.<n.+aarsd.an Ot-
t ,
Fas- tlecxfE: boot Attschwnt• r
raIVciiZ?lf(Of he1.l
t!
fl€Ishiny � �- :rw[Jn. bNe tf 506- S17 r11esti Slue; Lag Gall
Jill r:,.•:x :mid Fill !irate:
••a�xuka man �i+'hM :U'M wec6:eu4r nr,d sewed Je Vt J10. rt:l, eaf+x.s�t e•:h?:J
1• \ �� - rho nu�tlo-faa I
Ll ^� ••--a^•-^ - rl ll:5 al►,t-u 00 wvtitlk rpdermty H,d lair PT.I•,k!; a1i;1 tru9 ••n. s e!.:'7lho rj, ,;y r:' fi r-
jt)1 1 f l•t14a�n PrlC :Oa n1a111N aCJ'CI tlU<ya:rPEJ/Y;U+JnnI:L.4{1Jfi*�11 i�Y,n Cr11.•etPsliYC C.•' /
j '-.FdQAnCd 1,•Ihd ';,MI JI�.i/ 7Q'�Ae)
i i r,tedlrtl le:trft. pia 8', ]�Js ti'1:1!rl
tt ••!'v {n^+•tlld renrcr qym o¢J<dm2A mfah tn_••✓ i .
< lea le:itd :Uvtt141 atlacnmel OOV017i-t"l sill It?rCZR
:•n9udax (ac7n:1. : Tsetia:. cent fe>ml,a' 1:aa en aeon arytaU w � P`+a :y,icn+•
1a - � y Tn nu o:lnd Oaks, e] bt]a2 / � rinsarJsa:aJR[Jirrf'2d:r:Ir fJCVdrr�cs'Rr!n ::C M1.:;La,a'JI
Fr1ge 1 012 RT_5 1-tob J �,Mv7egxen
' r t
2X4" eilghieered tri,i5ses, 16" OC
. r -
NOTE: PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING,
MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMIILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS
NOT TO EXCEED SIX (6) FEET. (CEC SECTION 690.4(8)) `
NOTE: PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC SECTION 690.4(E))
t-
Page 2 of 2
Roofteac, L
Solar Modules
Static load test illLIStralion
PT-6
W
U
z
az _�
J V)
uJ
of LAI � L6
z z N
N
> O M
aQ
LU a- a
J Z U
a Q W Q M
O Q F-
1--1 _zcozd
-D05
d �a0
LU WOOJ
a a
w
W O
>.-U
ck: N
Q ' to in M
0 2 U Q
NNF U�
LI M
zV)
Q Z W Mc1J
a. r�Mn
ogrn
N -i
M a- U
J
4/1/15 _
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---
s ft
m-2
3
END
7 GENERAL NOTES: INFORMATION , GENERAL NOTES �.
VALUE DESCRIPTION
(8) PV ARRAYS 1. F SERVICE PANELS DO NOT HAVE EXISTING #GO
GROUNDING ELECTRODE, IT IS THE CONTRACTORS
(6) STRINGS RESPONSIBILITY TO INSTALL A SUPPLEMENTAL Module Wattage 315W Input data from PV Module data sheet
GROUNDING ELECTRODE. 1. EQUIPMENT -SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF
1 #6 BARE COPPER GROUND TO BE ATTACHED TO EACH Number of Modules 54 Total Modules for PV system THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION.
NODULE DIRECTLY VIA GROUND LUGS AND ATTACtm 2. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE. MODULES TO EACH RAIL WITH LuOs Module (VOC) 45.6V Input data from PV Module data sheet [�
1 EACH SOLAR MODULE SHALL BE GROUNDm USING THE 3. INTERMODULE WIRING-DURASHEATH LOW -VOLTAGE POWER, UNSHIELDED, FPR HYP, VOLTS: 600VDC. U.L
SUPPLIED CONNECTION POINTS IDENTIFIED ON THE Module (VMP) 36.5V Input data from PV Module data sheet _ _ TYPE RHM/RHW-2/USE-2 CONDUCTOR SIZE (AWG/KEMIL) 10. RATED AT 90' WET OR DRY WITH �,/
MODULE PER THE MANUFACTURER'S INSTRUCTIONS. MULTI -CONTACT LOCKABLE CONNECTORS
Module (ISC) 9.35A Input data from PV Module data sheet
® 4. ANY DC WIRING RUNS IN THE INTERIOR OF THE HONE SMALL BE RUN IN A METAL CONDUIT OR RACEWAY W
Pv Module (IMP) 8.71 A Short circuit data from PV Module data sheet AND CLEARLY MARKED 'CAUTION DC-CIRCUn• EVERY 5 FEET PER CODE REQUIREMENTS.
(2) #6 ECC 94VERT13t5
(N)AC UTILITY _ (D NICE PANEL Max VOC of Inverter. 60OVdc / 150Vac Input data from Inverter data sheet _ 5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE SONDED. co
` DISCONNECT V
nverter PPTV Max Curren 30Adc 56Aac Peak Power TrackingVoltage from data sheet 6. IF THE CONTRACTOR'S
MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING DECTR00E IT 6 THE PV
5 I - - I / 9 CCHTIRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. � _„-
LLJ
77' Average high temperature 'F 7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING to
1 ' 1T IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A NEW SUPPLEMENTAL GROUNDING ELECTRODE L._.1
® I I 29' Record low temperature 'F S. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER
(1) 18 EGC ® i Modules per Branch g Module string configuration NEC 110.3(B)
BOND To aHAsas (TYP.> (1) EGC "i -� Number of Branches 2 2 2 Module string configuration 9' hR►�6NNSLertnhSIid PER NEC
iutE'nNo �noSING WDEs M"A agzICAL m INTOCK "E aFF aa�snai T°ua
Branch VOC 410.4V Module Voc x Number of Modules per Branch 10. LABEL 'PHOTOVOLTAIC UTILITY INTERACTIVE INVERTER" AND 'WARNING POTENTIAL ARC FLASH HAZARD CAN
(N) ATTACH NEW GEC TO DOS71NO BY IRREVER9BtE MEANS A
CAUSE SHOCK, F1URN, OR DEATH.'Branch VMP 328.5V Module Vmp x Number of Modules per Branch 11 LABEL 'PV SYSTEM UTILITY DISCONNECT SWITCH' SNITCH COVER TO BE LOCKED AT ALL TIME& SWITCHBOND CHASSIS (•) - TO BE VISIBLE BLADE AND ACCESSIBLE PER U71UTY REQUIREMENTS AND CONFORM TO NEC 705.22
Branch ISC 18.7A Module Isc x Number of Branches
VERALL SYSTEM AMPR 90.87A 630OW x 3 = 18,000W/208V= 90.87A 72 1 ABET PER BREAKER 'PHOTOVOLTAIC ELECTRIC POWER SOURCE' PER NEC 705.10 AND 'BREAKERS ARE BACKFED• v
GROUNDING DETAIL PV SYSTEM VALUES 'a INNSS'TRV�ONS'WILL BE GROUNDED IN ACCORDANCE WI,H cooE AND THE MANUFACTURERs INSTALLATION L?
O
14. 1ARM 'CAUTION' SOLAR CIRCUIT SHALL eE ON ALL EXPOSED CONDUIT, ENCLOSURES. CABLE A55EMBUES, V)
MODULES TO INVERTERS JUNCTION BOXES AND ALL AC CONDUIT ON MICRO -INVERTER SYSTEMS LU LJ
BRANCH msp rated 800A X 120% = 960A of Lj
TOTAL PV SYSTEM RATING (MODULE WATTS) X (/ OF MODULES IN ARRAY) (315 % 09) - 2835 QUOITS The Sum: 15. SEE DEBATING PLACARD AND 'LOAD CALLS TO BE FIELD VERIFIED BY INSPECTOR AT FIRST INSPECTION- Z O N
MAX PV SYSTEM VOLTAGE - (VOC VOLTS) X (/ OF MODULES) X CEC FACTOR (45.6 X 09) - 410.40 VOLTS x 1.14 - 467.86V < 600V INVERTER MAX VOLTS, compiles mcb rated 800A + 120A - 920A 16. PV CONNECTION IN PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) EPID FROM THE INPUT J Z �yZ1
MAx CIRCUIT CURRENT CEC FACTOR % (TOTAL SYSTEM WATT/ TOTAL SYSTEM/ VOLT) 1.25 X (2835/410.4)- 7.26 AMPS x 2 strings - 14.52A - LOAD TO INVERTER < 30A. 11'�=anomalies System Complies, the Sum did not exceed 120% FEEDER LOCATION OR MAIN CIRCUIT LOCATION. > 00 M
INVERTER TO SERVICE PANEL SYSTEM-S86000TL LU
LU a Q Q
MAX INVERTER AC POWER OUTPUT - (MAX AC POWER OUTPUT) 6300 QUAILS 800A MAIN
PV SYSTEM BOM J Z
MAX SERVICE VOLTAGE m 110 240 208 �� ,.. Q LL Q M
MAX CIRCUIT CURRENT - CEC FACTOR X (MAX INVERTER AC POWER/240) t25 x (6300/20e) - 37.86 AMPS ITEM: DESCRIPTION: QTY. iZ�1 _z m z
WIRE CHART NEC 3f0.15(RX3NA) �L % 3 INVERTERS - 11158 AMPS
fIOAWG 090C m 40A x temp deratlon of 80% for 4 conductors m 32A > 14.52A, syatem complies _ U J O 5
/8AWG 090C - 55A x temp donation of BOX for 4 eonduetons - 44A > 14.52A, system oemplle3 00 (1/O)AWG 090C - 170A x temp deratlon of BOX for 4 conductors 136A > 113-%k *)atem complies O PHOTOVOLTAIC MODULES: SOLAR WORLD ` Q
/BAWG GQOC - 55A x temp deration of 80% for 4 conductors - 44A > 37.86A, system eompOes MODEL: SW315 MONO, 315W 54 /^ Q
#SAWG 060C - 55A x temp deration of BOX for 4 conductors - 44A > 37.86A, system compiles o- U) Op J
PV ARRAY 1 O SURGE SUPPRESSOR - MNSPO-300, SEE INSTALLATION MANUAL 0 W
1 STRING OF 9 O - PV 120A Q
SB6000TL O PV 125A SUB -PANEL 1 7)
�. U.1
7 CITY OF LA QUINTA � '... 4 P.mDtc NHongti Dgx film-. in 3
PV a INVERTERS: SNA AMERICA. SB6000n-US-22
�F a BUILDING & SAFETY DEPT. 0 3 I
APPROVED
d reserved 0
of oz o3 oa as 06 07 os o9
FUSIBLE (3) 31V GUT CONDUIT FOR CONSTRUCTIO �i AC UTILITY DISCONNECT SMT04 (200A. 208VAC, NEMA-3R) 1
(9) /8 THHN-2 v
PV ARRAY 3 1 JBOX #8 THHN-2 (CHO 8o SYSTEM GROUND 1
1 STRING OF 9 o I A DATE BY W° M Fo-
566000TL O 81-DIRECTIONAL METER TO BE INSTALLED BY UTILITY COMPANY 1 J a' Q U) M
01 02 03 oa Os 26 07 oe H>s PV SPECIFIC _
I
SUBPANEL I MAIN SERVICE PANEL MAXIMUM NUMBER OF MODULE IN STRING: Uy F i v
M
PV ARRAY 4 O 125 208V r OPERATING CURRENT: 17.42A Z Z (nM K�o 1 STRING OF 9 3 PHASE J I
(E) 800A @208V,
OPERATING VOLTAGE: 328.5V - M
Ol 02 03 04 OS 06 07 08 09 4 oat 4Hu 3P/MCB 800A MAXIMUM SYSTEM VOLTAGE: 410.4V C Q
FUSIBLE 411A 40A METER MAXIMUM SHORT-CIRCUIT CURRENT: 18.7A e) a J
LMLITY r
PV ARRAY 5 O J'5 4aA 3 - 208VAC o
STRING 9
o M Z
I, 9 z
566000TL �
E
03 04 Os 06 07 08 09 -
_
PV ARRAY 6l"
(3) 3/4 +EMTc TRENCH
ONDUITIT - O r 5/28/15
1 slT:�c of e 1 AC UTILITY
O OS (3) #6 THWN-2 (CND) _ , r DISCONNECT SWITCH (N)3P/MCB 800A DRAWN BY: BPM
40 _ 200A, 208V, NEMA-3R I (Of, I 1 1 ryplcaLAwc wire sizes _ APN: 767-710-03-6
Ol 02 03 M 06 07 FUSIBLE s -y Wire
JBOX Size
PV SOURCE CIRCUJ �ooFT _
- (8) #10 USE-2 PV WIRE - P 1-3P/12OA 14
' (6) /10 USE-2 PV WIRE - NEGATIVE �/T gyp}-tbahl e. 12
(6) H6 BARE CU (GND) /� S G I I i
• (3) PO THMN-2 - POSITIVE i IJ "Z 10
SINGLE LINE WIRING DIAGRAM /10 THHN-2 - NEGATIVE P SEIQ�vISE rb - B
7HHN-2 (CND) 9 6
1 (3) 3/4- EMT CONDUIT +PVC L H �'' 4
SCALE: N.T.S. RUN FROM Jeox ON ROOF To IrivER ,
- 4 WIT HEIGHT ON ROOF - _ (1) 1-1/Y EMT.CONQUIT. , I ,' :3
. (3) OD (1/0) T KN-2 I
1/2"
3/4"
1"
1/4•
1/2°
2'
EMT
EMT
EMT
EMT
EMT
EMT
12
22
35
61
84
138
9
16
26
45
61
101
5
10
16
28
38
63
3
6
9
16
22
36
2
4
7
lz
16
26
1
2
4
7-
10
16
1
1
3
6
8
13
o,m,m
turmtel,of
�eB
Come
J"°e
o00el mre
emwcv
F�
OMn
10 R
sa
msulaa
015,75
65
3EE'
1531
66
)36
OS 17�
0 563
"R
13
o22°J
sae
436'
t 2'
s26
267
9w6s
o 9;o
esl oar
0 OJ)
5 69
BSI
197
Ji
f12
0a15'
02J65
0 a5 95'
�
t "
O1BiB
J6S
550;
21
)31-j
166
1026
03133
�-
r
01610
115
613�
63�
il3
D6
0)951
55 a51 5
91JJ3
3fi65
69
27)
268
_10511634107982.�-
012a5
3 6J'
I_6'
l06
165
ell
206
06282
50/55.
r.D11J
290a
87 fll
31
663
259E
079211
r40
0We11�
u wea
nc
LOT: 1.86 acres
DWELLING: SFR ---s ft
�_�
E-1
4
%a
1160
U*3
r - - (1) fO (1/0) TMHN=2 (GND).., -L-- 2 1 1 3 5 7 11 to 010 9 zs6e 9eu 3es �? 526 32 7 o" 30 3s,ao -_ _
tA
Sunmodul Pro -Series XL
SOLARWORLD
Sunmodule,-/" Pro -Series XL
SW 315-320 MONO
REALVALUE
SW 315-320 MONO
PERFORMANCE UNDER STANDARD TEST CONDITIONS
(STQ'
SW 315
SW320
•
_.
Maximum power _. _. P,,.. -
_315 Wp
320 Wp _
Maur-e
rcultvWtagr -_ --_.. _ V„
.
456V
059V
oI TUV Power controlled:
:-.
Maximum power point vottago V,,,,
36.5 V
36.7 V
lowest measuring tolerance in industry-
S
--
Short circuit current 1
9.35A
9.41A --
°--
Maximum power point current I.r
- 8.71 A
8.78 A
Module efficiency r-
16.03 %
16.28 W
Every component is tested to meet
Meawuny tolmanee tP 12 •�.>blc h, TIrV ra a.n4,ru} . ? ,. ;TU4 Vorr•r 5wrvuacd,
`STC. iiR10W,'m'. 25'Y,1(M t.5
3 times IEC requirements
!
w
✓
PERFORMANCE AT 800 WWCT, AM 1.5
Z
w
sw 315
SW320
LU
L
(
Maximum power P, ,.
2409 Wp
244.4 Wp
Z
UJ
U W
Designed to withstand heavy
9 Y
pen circuit volts
O ye V
398 V
40.1 V
Z N
accumulations of stmw and ice
• ✓
Maximum lower puint volleys' V,.,,,
33.6 V
33 8 V
Z N
C
Short circuit current 1
7.77A
7.82A
a c
d Q �_
�
J Z U
Maximum power point current I r
7.18 A
7.18 A
Q
SUntnodulePlus:
L
Minorraductwnine(rir15!ntyutxferpart:allaadcneM,tinmatTS 'C:et700W;m
,100a,ia7-2'4)oltheStCetlx;ency(tOOpWm "Isac
ihiewd.
Q �
Z M
Positive performance tolerance
J
Z
✓
l uoo w:m'
DIMENSIONS COMPONENT MATERIALS
'
-
^yy�
FM w: m,
length 78,15 in (1985 mml Cells per module
72
0
W Oa J
yyc. 25-year linear performance warranty
Width 38-98 in (990 mm) Cell type
Mono crysta8ine
<
Q
and 10-year product warranty
rS2r-'
9 Hei ht 1.81 in (46 mm) Cell dimensions
156 mm x 156 mm
w
✓
5aao �
wrm'
frame Clear anodized aluminum
Front
3 2 mm Tempered
peredglasz
H
a
Weight 496lbs i22 S kg1
(EN 121SO)
-'
200 Wim'
I
J
OOw:m
THERMAL CHARACTERISTICS ADDITIONAL DATA
j
I
t V
NOC i 46'C Power sorting
0 Wpi a 5 Wp
I
World -class quality
Fully -automated production lines and seamless monitoring of the process and mate
ove
-- — -- -_--
t U.• 0.042 aolK 7-Box
IP65
w o
) •— I
N U
'_
quality
nal ensure thethat the Companysets as its benchmark for its sites worldwide.
.,.:..
�e - _ 1
TCV., -0.104 °a/K Connector
KSK4
y w
N _ H
SolarWorld Plus -Sortie g
Plus -Sorting highest system efficiency. SolarWorld delivers
.,w.,,,,...
/1 ,.,.,.
`J
V S
T j' fr 31 U.'G /' t 1
1
1-- f
TCP. 0.43WK Mndale fire performance
!'141703)Type t
m m Q
Q � to N� �I
<W cV)a i
= U
guarantees only modules
PARAMETERS FOR OPTIMAL
that have greater than or equal to the nameplate rated power.
Ut 1703
I
SYSTEM INTEGRATION
_ U
25-year linear performance guarantee and extension of product warranty to 10 years
�`�
�11r
♦ • i i
r r
I
Maximum system voltage SC H! NEC
Maximum reverse
1000 V
M
Q W
¢ Z �j
E3
SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course
current
25 A
-1 0 co r,
of 25 years, a significant added value compared to the two-phase warranties common
...
�� -; �
Sly
load: dynamic load
r
1 t 3r64 psf ,5.4. 2.A kNrm �;
0-
o 1 rn I
in the industry, along with our industry -first 10 year product warranty.'
I
w
-in
Number of bypass diodes
3
d v I
accordance with the applicable SotarWaW Limited Warranty at purchase.
Operating'ange
40 - C to .85- C
www.solarworid.crms/warranty-
D 4 Uri i l;nw,l
W
7
solarworld.com
Quality e10dYle5
m d mliNrl
ow
, ♦
— ?
i +^'
to n.;4Mnmi
(n
_�_
4/1/15
DRAWN BY: BPM
APN:767-710-03-6
All-1, provided are imperial. St umts provided in parentheses.
LOT: 1.86 acres
sotarworkt AG reservesthe right to make specirxation rhanyes wrtnnutrrotre.
0.98 m.i25mm;
SW-01-6056US 112014
DWELLING: SFR, ---s ft
MODUII F DATA SHEET
D-1
1
SCALE: N.T.S.
5
NOW AVAILABLE FOR i
Innovative
• Fist tramsfommtloss SMA inverter
:o be cemfied in occardonce with
UL 1741
• Fiw invert. with arc4mh cecuit inter
ruper Inted according to UL 16999
Economical
• Maximum efficiency of 98.7%
• Ciassfoofdg CF.c eRiciency of 98.54
• Superia Mil tracking with
Opt7rac"
• Tmnsfor de.. vA H5 topology
Reliable Convenient
• OphCoor" active lempefclkre • [,.". ,oted DC disconnect
management • SMA Power Batarx. fcr three
phone grid connocnon
SUNNY BOY 6000TL-US / 7000TL-US / 8000TL-US /
900OTL-US / 1 OOOOTL-US / 1 1000T1-US
Tronsformedess design, "noximum energy productior
The Sunny Boy TLUS series is UL listed for North America and features SMA's innovative H5 topology, resulting in superior
efficiencies of more than 98 percent and unmatched solar power production. The tronsformedess design reduces weight,
increases the speed of payback and provides optimum value for any residential or decentralized commercial PV system. The
Sunny Boy TL-US series for North America is the ideal choice in tronsformedess technology.
INVERTER DATA SHEET
�� SCALE: N.T.S.
.... ... fffaf .e UNNY BOY 5:i0CT, Li i .._.......
aa-
W � J
0u•p.< po,,,rr Rated Grewyr
Technical date
Input (DC)
Mox usable DC prwar (0 cos .y - I I
.Max DC v Atage
Rated ♦4Pr:.0hage forge
MPPT aperamsg r4,oge range
Min DC v:�linge ; slot• vatnsge
Mo. input cunenf / Per MPG mocker
Number of t✓,PP trackars / strings per M?✓P tracker
Ouepuf (AC)
AC nnmioal pnwer
Mox. AC opponent power
Ncrrsinai AC wohoge / adjustable
AC voltage wnge
AC grid frequency. rouge
Mox outpsn current
Power facfa (cos ,P)
Output phases / kne crinrecfions
Hormown
Efficiency
Max efficiency
CEC effic ency
Protection dehces
DC disconnection device
DC rare sp{salnr ty proee chon
Ground fault mondoring / Grid monitoring
AC short u—.1 prateciion
All -Pole unsmve fesKduol c�nene mondoring unit
Arr fouh c,rcue (00) comp6m to Ul 1 699E
Prntection 8= j overvoltoge cotegry
Genera( data
Dit'lem;ons (W ; H / D) ui min (in)
DC Disconnect cl^envom fW / H / D) r mm (m)
racking dimensions (W ; H / D) to ton lini
OC D we rntect Pocking dimensions (W / H / D) m mm (rn)
Weight / DC Disconnect weight
Packing weight / D- Disconnect packing weight
Operapng tempererure r0n134
Noise emission (ryp.col;
Internol consumpnan of nghr
opol°Oy
C4 Jl.na3 �r..sept
c'iectrnnics protection raring
Features
5e "u Pavver I uVwy
Display: graph::
IntedacesRS485 / Spee-dwirefNyabconneU
Wononl y. 1 C ! 15 / 2C years
:-ertificoies and permits (more available -tensest)
Sunny Boy 40007L-US
208 V AC 240 V AC
A200 w
600 v
175 - 480 V
125V-500V
125V/150V
24A/15A
AC-00 W
4000 VA
208 V / • 240 VI •
83 - 229 V 211 - 264 V
60 Hz / 59 3 - 60 6 Hz
20 A
1
<4.
Accessories
trwAr,•,m'W�bc 'aa ,� R,.sES ..•ts4x� _.
+++edoc< D1nsR� •"SLIS I t
:w', tA41 t514 -
• Stwsdard feature 0 Ophorwl feature - Not avoiloble
Dwo w aom.ial cundeons
Sunny Boy 500OTL-US
208 V AC 240 V AC
53D0 W
600 V
175 - 480 V
125V-500V
125V!130V
30A/15A
2/2
4550 W
5000 W
4550 VA
5000 VA
208V/0
240V; •
183 - 229 V
211 - 264 V
60 Hz / 59 3 -
60.5 Hz
22 A
1/2
a A%
Sunny Bay 600OTL-US
208VAC 240VAC
63C0 W
600 V
210 - 480'V
125v- 500V
125 V / 159 V
30A/15A
520D W
6000 W
5200 VA
6000 VA
208V/•
240V/•
193-229V
211-264v
60 Hz /
59 3 - 60.5 Hz
25 A
1
112
< a`a
96 8 G 97.2% 96 81A 97 1 % 96.6 ro
96°6 96.5% 969:, 96 5°•.. 9610
97 1` '
490/519/165 (193J20.5l7.31
187/297/ 190 17A/ 11 7/75)
617 / 597 / 266 (24.3 / 23.5 / 10 5)
370 / 240 / 280 114.E / 9,4 / 1 1 0)
24 kg (531b) / 3,5 kg 181b)
27 kg (60Ib) / 3 S kg (8 Ib)
-40°C •60'C (-40'F +140'F)
< 25 dB(Al
< 29 dB(A)
< 29 d8(A)
Trrmsf;,msedess
Transtarrnartess
Trtsns{nrmertess
Convect on
Comr clan
Active Cooling
NEMA 3R
NEMA 3R
!'irmA 12
0/0
0/0
oJo
0/0/0
0/0/0
•/L)r'o
UL 174I, U1 1998, Uk
1699B, I£EE 1547, FCC Pon 15 ((:foss A d 91. CAN/CSA C22.2 1C7.1-1
• Pret:rMs N durtr us �f ,L. 41, 24) 4 s I „,TF 115 imrerMrs shin with gnty hds
Type desigrnnnrn 58 4000TL US-22
Toil Free +1 888 4 SMA USA
www.SMA-A.merica.com
58 6(yX;!L11S-11 SB SOCOTt US 22
SMA America, LLC
W
V /
Q
LLJ
C2
LU
i--1
hn
IA
W
U
Z
W
0
(n
W
WwLCj
Z D N
Q W N
:2>01 t
d Q Q
j Z U
Li
d
OQIQ. r7
Z M Z (0
_j0D
.,6 "d-
LC)
Q
U) 00
w
71
H
W O
> U
[r N
N
D � m
�w
Q
j Q V)
U 0 U Q 7
U) N J
t-U�
W = w 1
ZQ(n- O
Qzwr7cD
j0000f
O :2 O)
ONOQz4tz
rM 1 U
6i
Q
4/1/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR,
D-2
G
Assemblyof the SolarWedge
g
Components of the SolarWedge
system easily integrate with the
Attachment Parts List (Per Box) Not to Scale
Shipped in a shoe box sized package, the SolarWedge XD attachment
components offer easy handling and storage along with reduced shipping
F
Solar. W
d9
Revolutionary Commercial Mounting System!
SolarWedge by Professional Solar Products. Inc, is an innovative tow
profile commercial/residential PV mounting system. The system provides
an easy to install and economical solution for 5, 10 or 15 degree
toadresp
liorL—d
30lbs.sq.ft wind Loaf
AtG on center
`1 f
new XD support (all.
,
;
�
hy� --
t
costs. ` 1 \
12 ea. (1- _ � 24 ea.
Q 6 ea. !p Aluminum 1:'2" SS Flat WashersP
Compression
I" Dia.Aluminum Nuts
Rear Posts �J 1 2 ea.
12 ea" 318" SS Flat washers
Aluminum
6 ea. �'Lower Rail 36 ea.
ont Aluminum
Front Posts 1 2 ea. Supports 1R" SS lam Nuts_,.,
I i2' x 4" S5
12 ea. Leveling to 12 ea.
structural attachment. SolarWedge integrates with Professional Solar's
patented "top -down" commercial Rooffrac and Foamlack' stanchion
�—
1.5" Dia. Studs 3' x 3' Aluminum
Aluminum Seal Plates
products. The system dramatically lowers installation and shipping costs
while optimizing installed wattage on the roof.
Advantages of the SolarWedge
Easy handling and Installation: Each box supports
y g pports up to 30' (front
& rear) of RoofTrac * support rails
• Integrated Leveling System: Compensates up to 2-1 /2" of roof
variation using an included 112" x 4" stainless steel stud e
•Degree
Fully Engineered: Load tested to30lbs. per sq. ft(approx -
mph wind load) at up to 6' centers _
Finished Aluminum Parts: Clear anodized angled support
brackets match support rail. Foamlack ' stanchion parts are
machine tumbled and cleaned to provide excellent bonding of
P 9
foam, flash or
Precision
Precisionextruded angles of anodized
aluminum campressthe support rail al
a fixed angle while dramatically
increasing the strength
• .
'
. r ..:
-
`
% Bases
j
AttachmHnt Box Dimensions
Each box contains enou h
5pecitit atrin; are attachments to g I— 6" _7
Fully Assembled Subject to change-
install up to 12"
without riotici,.
3.3 kW,,
Standard SolarWedge Technical Information t° 80.
Ormens+ons S" 3.3 kW
> Load Tested and engineered to 30 Ibs.Ueporox.1 1 omph wind Toad Illustrated , •using 2lOw ,,
equivalent) L modules
------------ -- _..
> Utilizes FoamJat[Laboratory tested to 2,870 lbs. vertical and 2,615 lbs. side
lateral pull out using a 3/8" x 6" lag bolt (secured at approx.6 1 J2").
> Structurally attached to the roof extremely important in areas with
potential horizontal and vertical seismic movement such as California. -
-
charges. > Available in`510)or 1Tangles.Optimized to helpreducetypjcal- " - -� � 1 Rp,ir Extension Hev.lht
peak summer demand ch- - ~J j
- ' - -- 15 Degree
tu
w
=
(1)
Q
I-'
Q
z
w
U _
Q
w
W
o
w
? uj
z
Q Z N
w rn
g > M
a- a
a Q_
Zvi
a F M
Z m z 0
J o -5r
�js C3,
n
� � �
w
Q
Stud rolls into the post u to 2-112"
Po P
to eliminate the need for cutting studs
on the job
Rail Insert -
Fc„rnl..rck Compression Nut
Each kit includes the Foamlack
with a 3" aluminum seal plate. a
Size included depends on the 1/2" x 4"
angle purchased Leveling Stud
y
,.
Raitli7wer
d * i Supper
i ,IIt Fxtr'.nsiorl I'ieio ht �;._.--�"
All Angles -� - _=�--
- _ - - - - - -
t_=='�
or product and purchase inquiries contact.
eCO D I R E C T j
-
-- —_l�- - -i 19"r/.34"
r-"� - _ .
- - - _ - - - ' 10 Degree
- - - - - 14-112-+�-3;4•
5 Degree
n"+,_ 1 a
;, .-.
4' O.C. ►l
Rear View
2.5" Support Rail
6' S an between
attachments for commercial
construction only
I
I
w d I
v U
Q
w p
J X ¢ � M 1
O oz
n to
w Q
z vi o
Q Z Ld M D
o 0 00 ti
o M rn 1
cc¢ �
a I
l
Roof Surface
Modulesare mcxrntea in
the rlustrated dlrc<tio 1 to
op
optimize p nthmarue in the
Summer rrtanths `
-�
Foamed bases
as illustrated
CLEAN FNFRGY SOLUTIONS
vnsw.ecodvect,com *"__..... ..—_."_,�-,____.�__�.�._.
6' O.C. __.___'---_._,-_._.__�♦I
c
Drill GUI % ' (J ( � d k P a f � 1,-: � Y
�w
�
to
professional (805)486-4700
�I Three � . ! t ,..
5/14/15
DRAWN BY: BPM
AD )';r'V�(' �(O
=s
APN: 767-710-03-6
01 , i 1 ,., Fir ,ram Ave
!
�..7i�C�d�,l�..s.tS vxr;.nr�i t_�r":,[lt"f
www.prosola ncorl
i . 1 - •
The FoamJaciclrill guide ensures that
pilot holes ary drilled Vu degrees to the
LOT: 1.86 acres
DWELLING: SFIR, ---s ft
swzooexl sz,
tete�n +c.. 4e.O.�fi1 .;r,�u•.a�n,z rafter/beam optimizing the strength
and appearance of the connection.
D-3
ATTACHMENT DATA SHEET
1 SCALE: N.T.S.
11
.Roof Trac
The Original "Top -Down' PW Mounting System.
l:i7JaYhlr:al :. _.. -. ; -6e
:if1ilibfrx7if aw.iiyp"ih ,rAkkrakv aWh tiv,
u* 1J$c a'd7€' te< fT l� r#tt7
i (x l,7s�r art ki J eul n f �r mrru>: big on a Ide nx
III'A- MAW * 1 V&'M? �y IM*e l Ak i1nd 1_141• a&'dl?
fIx• riz€tiiltrr !�� narslfr°.�strril' Jr1r4,Jr�riteYt�s li lie° t•ra of rear
' z•t ;' ttE `" t ; r it is h G £ruff ` it tWr'U11xfrt rak
t;; trr lu%r vets G7 tx»rt 7eirrix r %rfr rirtem n45
'lif %kL4:� !u yf'rtY K'r1J i{cYNhi3jR' ;. : ,+: t'
:"!?7JSriN.A�"tA;tlt RttliP;S+c'+ .
, dt n`ed -N-Clamp
J-Ci
S'Y,stet?
SOLAR
� ATTACHMENT DATA SHEET
1 SCALE: N.T.S.
bad' 1.2cl V fast lait p?tt'"d avu,
` um * 4.. 4 V otbe'e ^P."r'dtl y^k"lMAi
Uc T,.C* P.MICKC Uwe, P.K4t r5A&,nl9
-
�JIlIRslit+l±?T
�LCti� exyiT �ll�al s r)atr ±l2 .+ i.r 1: sz ;_ ,
t^r'jit�'!+ nt r'+'il�ir!�S'di4�{ttl 'i )tt';SC•.RG;VL., _:t.. ... s !'i
Pt?�a�tryk t)
•7r�iti�i�i"i`�tPif��aJR'r�ial;k 1�'tie:�Pr?ittl e:Ai?Yt k ., ,.,
t'i7, rtt{Nf'rl}tr trieb jwqic I.,sx k ,rrliyne Our titnwattnt
i.'ki7tl!rit ' .<i�lt'i?f .+7Yil Pt -�+ inuar€J`lc'twpwi un .1he "velule
trione *i urm,,, * tr "vittilt' in A• lr"ame.
Roof Trc7c IN
- -, z.P
The Original "Top -Down" P'V Mounting System,
i _,tilted vvlt 1 P-d-st ..1_7ic a,-tdc 1mE-;i;=,
a1a.4dc't
:i ,.. .. -.�. .. i ii�11J.'r:.Staf��i: i .a• '.. .., r' Y=.i
• , r3rr {tip ; , � w� tJ
f
Roof %x, W cast lack p, nr:re•a urdc
PstCh :6,36OA91 C Othei ,te ems pf-4ri3.
rlkt 3fst:r Prarte=_,e�- un,aet Pef-" V5,64e.429
L:j; *% So Ise Kit
�g .�fi i�t?tP .: _: ,�i�l' 7' ..x�G,`•� :� .�, , , ; tttii:+. � �7t t.'ts, c: �':7':
s
f7i �• .
W
U
Z
W
W
Of W Lrj
LU ZZN
Q W rn
V) a- Q M
d
Q aZU -
Q Q QM
O Q F—
M Z
J O D
J di t C3
�QJ Ln
Li. WLd
Q
W
2
H
O
I I
>�v
I
� N
H
cr) d ]
W
CtrQNM
ODUJ�
N U
I
r>'
ZQED
U)
QZ WMtD
aoocor
N —1
J
I
r]
Uj
CD
cn
5/14/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---s ft
D-4
8
JUNCTION BOX & CONDUIT RACEWAYS
NEC 690.31(E)(3) - CONDUIT / ALL JUNCTION BOXES
WARNING:
PHOTOVOLTAIC POWER SOURCE
NEC 690.35(F) - UNDERGROUND SYSTEM JUNCTION BOXES
PiTL1:7►11kw
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNDERGROUND AND MAY BE
INERGIZED.
DC DISCONNECTS
NEC 690.14(4) GROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
DO NOT TOCH TERMINALS.
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE
ENERGIZED IN THE OPEN
POSITION.
NEC 690.35(F) UNGROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARF
UNDERGROUND AND MAY BE
ENERGIZED.
NEC 690.14(C)(2)
PHOTOVOLTAIC
DC DISCONNECT
NEC 690.53
WARNING PLACARDS
1 SCALE: N.T.S.
INVERTER
NEC 690.5(C) - GROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
IF A GROUND FAULT IS
INDICATED, NORMALLY
GROUNDED CONDUCTORS MAY
BF UNDERGROUND AND
ENERGIZED
NEC 690.35(F) - UNGROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNDERGROUND AND MAY BE
ENERGIZED
DC DISCONNECTS
I
1MV'ERTER.. —
PRODUCTION METER AC DISCONNECTS
ONLY AT METER LOCATION NEC 690.14(C)(2)
PHOTOVOLTAIC PHOTOVOLTAIC
SYSTEM METER AC DISCONNECT
NEC 690.54
NEC 705.12(D)(4) - ON A LINE SIDE TAP
WARNING: DUAL POWER SOURCE
SECOND SOURCE IS PV SYSTEM
Gl 6 9 t.71 i..j Qj U S i V I A
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
SATE BY
JUNCTION BOX & CONDUIT RAcFwAvc
CAUTION: SOCAR CIRCUIT'
i
MAIN SERVICE PANEL
NEC 705.12(D)(7) - NEAR PV BREAKER
WARNING:
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT PROTECTION
DEVICE
NEC 705.12(D)(4), 690.56(B) - ON PANEL COVER
WARNING: DUAL POWER SOURCE
POWER IS BEING SUPPLIED TO
THIS PANEL FROM THE UTILITY
AND A SOLAR PV SYSTEM.
THE SOLAR PV DISCONNECT IS
LOCATED:
NEC 690.14(C)(2) - NEAR PV BREAKER
PHOTOVOLTAIC
AC DISCONNECT
NEC 690.54 - ON PANEL COVER
r
U
ta.
(D
z
Q
w
U
z
w
0
V)
w
�wL6
Z U N
aZN
>a,�
aQQ�
J Z U
0QFQ-M
Z M Z 6
J (D
�Q
WCo
J
a
w
w O
� N -
� Q> 0]
Q (n M
JOQ(n�
O=UQd
0
w=w
zQU) �o
QZwn(D
a o 0 ro h
ogrn
N J
aaQ ztt�
r) Q_ U
r
w
H
Q
inI
I
I
5/14/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---s ft
L-1
9
Safety Switch General Information
Global Specifications
System Voltage
600 VAC
Switch Type
Single Throw - Heavy Duty
Poles/Blades
3-Pole
Amperage
200
Protection
Non -Fusible with No Neutral
Enclosure Type
NEMA 3R
Special Paint
ANSI-61 (Gray) Standard
Switch. Lugs
Standard
Fungus Proof Treatment
N
Lock -On Provision
N
Trapped Key Interlock
None
Fuse Pullers
N
Control Pole
N
Ground Lugs
N -
316 Stainless
N
Stainless Mechanism
N
Mill Duty
N
Namealate
Safety Switch Catalog No
DH364URK
The Information on this document is
created by Eaton Corporation. It is
disclosed In confidence and It Is only to
be used for the purpose in which it Is
PREPARED BY DATE
JOSE ALONZO 5012015
Eaton
APPROVED By DATE
JOB NAME TEST ,
supplied.
DESIGNATION
-
VERSION
TYPE
ORMING TYPE
1.0.0.1
Safety Switch General Information
Customer. Appr.
NEG-ALT Number
REVISION DN,G SIZE
G.O.
ITEMSTET
O81N0318XSK2-M
0 A
-
- 1 0f 1
m O)s
2
®
3
z
.c
a
Q
Z
O
wD
m
,
15.52 f394.21
OD
I 4.50 (114.3. 4.50 (114..
W W
W W
W
X�
�o
�j
�
u
0
KNOCKOUTS i0 8E OMITTED
-
p
pp
m
W
O
00
IN TOP ENDWALL FOR
FIG. NO. 2, 4, & 8
(\moo/fJ
n n
n n
n
n n
n n
n
C Cp
c_; N
ti N
Ncil
'
T Q
♦
'
Li
TANGENTIAL ,
:. X`
KNOCKOUTS
N N
`
.343 MTG. HOLE
N N
FOR FIG. NO. 2, 3, & 4
}
.75 [19.1]
11.26 [286.0)
C
15.91 [404.i]
_
10.00 [254.0]
v
C
.88 (22.4]—
X
x
t
m0
m N z
m c .56 DIA. MTG. HOLE
C 2 REOD. FOR FIG.
NO. 5&6
ti
a
U
U
z
It
2
CONCENTRIC
m
'KNOCKOUTS
r�
r
r y
Nb
iD
u
N
,O
r
N
N N
N N
N
O Y -
N N
N N
N
Z
a uo
a 'o
'
,O t0
N N
N
5 r• �
N N
O O
N Of
N N
n1�
n
1
h h
,D
O
D O
n h
O
N N
N N
t OMIT FOR FIG.2
m
n
aN0
m
B .
N
N
•
(ppO� ,pD r,
1�
.O 1D
100�p0
N h
m
m
g$oo�
Ed
•
l~V [CV
N N
N
Q ♦
0
'
'
.56 DIA. MTC. HOLE •-
6.00 [152.4)
^
�
n ^
g
._.
'
2 R DD. FOR & 4
12.00 [304.8)
—.88 [22.4] .
n N
o
¢
a
♦
06
N N
N N
Ml
A
m,rta
nN
a`a
A
_
—I
^go
t •
nowom.mmriro
m�i oo°iwao°�
WAMCMSIPE 1013/83
CUTLER —HAMMER
. f?
14
'�.
I
-
.•
o o�o'nmN11 om K° z � —
10/?�?
CILVEw ,+D _TEt++ES50E
_
•
r q
tom"
+
,o eo, n n nwri.
^I1.4
DIMENSION SHEET
200 AMP DH & DIG TYPE 1 & 3R _
m�
6�� -.
.maR o wiio
ma ooa�A1 qYi.—.
l
a
d
�aci me w,o
et
MM-1072 - J
"° ooa95-972
o�
,3
a OF 1
�'
Planet Solar Inc. 7/22/16
73-820 Dinah Shore Dr.
Palm Desert Ca 92211
760-341-1413
Planet Solar is asking for an Extension for the solar permit for the Lippman residence at 81-540
Baffin Ave. in la Quinta. We normally receive the approved plans very quickly but due to this job
using battery backup technology the approval process has taken much longer, also due the size
of the estate the job has taken much longer.
Thanks again for your consideration - ECREAVED
TY ?, 2 2016
Steve Pyle CITY OF LA OUINTA
COMMUNITY OEVROQMENT
a
81n.#
Gty Of Quinta
BuMIng 8E Safety Aivision
P.O. Box 1504, '78-49S Caffe Tampico
a� 1A.Qulnta, CA 92253 • (760) 7777012
Building Permit Application' and Tracking Sheet
Perinit #
'F�3-pL2-01�
Project Address: 8.
Owner's Name:.
A P. Number.
Address:
Legal Description: 15.E
Contractor: aw�T S p V
City, ST, Zip: ZZ55 Z.
Telephone:
ga'
Project Descripdo .
Address: 7,1>'22,o ►tio. S t2 vy' �¢_
City, ST, Zip: Fatyw,—rl>+
K
Telephone:
State Lie. #: �(3 ( City Lie'. #c
Arch., EW , Designer.
Address:
City., ST, Zip:
Telephone:
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: # Stories: #Units:
State Lic. #:
Name of Contact Penton:
Telephone # of Contact Person:
Estimated Value of Project: (p 3; d b b
APPLICANT: DO NOT WRITE 13ELOW THIS LINE
#
Submittal
Raga
Reed
TRACIMG
PEsRMT FEES
Plan Sete
Plan Cheek submitted
Item Amount
Structural Calm
Reviewed, ready for corrections
,
Plan Cheek Deposit. .
Truss Cales•
canes Contact Person
Plan Check Balance
Tide 24 Cake.
Plans picked up
/!Construction
Flood plain plan
Plans resubmitted.'.
Mechanical
Grading plan
2'j Review, ready fo eorrcclioa =e
2 S
Electrical
Subcontactor List
Called Contact Person
$
Plumblug
Grant Deed
Plans #irked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
't° Review; ready for correetlonsJ11me
a
Developer Impact Fee
Planning Approval.Called
Contact Person
U
AXP.P.
Pub. Wks. Appr
Bate ofgertuit�ssue �� 4-�
School Fees
To
746 - (997
OCT .13 2014
CITY OF IA QUINTA
.COMMUNITY DEVELOPMENT
17.01 kW DC PV SYSTEM
AZIMUTH: 180'
PANEL TILT: 3'
(54) SOLAR WORLD MODULES: 315W
PV MODEL#: SW315 MONO
MODULE DIM: 78.15" X 38.98"
MODULE WEIGHT: 49.6 Ibs
INVERTER MODEL#:
(03) SMA AMERICA, SB6000TL-US-22
PV STRUCTURE:
SOLAR WEDGE ATTACHMENTS W/
PRO SOLAR SUPPORT RAIL
ROOF TYPE: FLAT JUNCTION BOXES
NUMBER OF STORIES: 02
ROOF TILT: 0'
ROOF FRAMING: 2"x4"
ROOF RAFTERS: 16" O.C. SPACING
STRUCTURE TYPE: SFR
NUMBER OF ROOFS UTILIZED: 01
(2) STRINGS OF 09 MODULES TO EACH
INVERTER, x (3) INVERTERS
PV ARRA
ROOF ACCESS AS
PER SECTION R331.4.1
OF 2013 CBC
CONDUITS 3/4" EMT -
ON ROOF/UNDER EAVE/
IN ATTIC
Q
ui
Ni
COY 0FtA QUINTA
BU1L.Dt( SAFELY DEP`L
AP MOVED
FOR CONSM=10N
THIS HOME IS NEW CONSTRUCTION
FIRE CLEARANCES ADHERED AS
PER SECTION R331.4.2
OF 2013 CBC
3'-0" FROM RIDGE & EDGE
1'-6" FROM VALLEYS
�3'
CRITICAL LOAD
PANELS, 125A EA
GARAGE #1
TRENCHING
(3) PVC + 1-1/4" EMT
TRENCHING
PVC + 1-1/4" EMT
PHOTOVOLTAIC INSTALLATION PLAN
1 SCALE: 1 "=25'
GARAGE #2
BATTERIES
ENCLOSED LOCKABLE
BATTERY BANK
MAIN SERVICE
PANEL (INSIDE)
800A, 208V
3 PHASE
VICINITY MAP
PROJECT LOCATION
THIS PROJECT CONSISTS OF THE INSTALLATION OF (63)
PHOTOVOLTAIC MODULES AND (03) UTILITY INTERACTIVE INVERTERS.
PV MODULES WILL BE MOUNTED TO AN EXISTING RESIDENTIAL FLAT
ROOFTOP USING SOLAR WEDGE ATTACHMENTS AND PRO SOLAR
SUPPORT RAIL. SYSTEM WILL BE 3 PHASE POWER AT 208V.
THE ATTACHMENT SYSTEM IS SPECIFICALLY DESIGNED TO WITHSTAND
11OMPH WIND LOADS AND SEISMIC LOADS ON EXISTING ROOFTOPS.
REFER TO CODE COMPLIANT INSTALLATION MANUAL FOR DETAILED
INFORMATION AND WATER PROOFING SPECIFICATIONS.
SHEET NO.
INDEX NO.
DESCRIPTION:
01
T-1
TITLE SHEET
02
M-1
PHOTOVOLTAIC EQUIPMENT PLAN
03
M-2
STRUCTURAL CALCULATIONS
04
E-1
SINGLE LINE DIAGRAM
05
D-1
PHOTOVOLTAIC MODULE DATA SHEET
06
D-2
INVERTER DATA SHEET - SB6000TL-US-22
07
D-3
ATTACHMENT DATA SHEET
08
D-4
RAIL DATA SHEET
09
D-5
INVERTER DATA SHEET - S.I. 6048-US
10
D-6
BATTERY DATA SHEET
11
D-7
SMARTFORMER DATA SHEET
4 12
L-1
WARNING PLACARDS mi
PREPARED FOR:
CITY OF COUNTY: CITY OF PALM DESERT
SMA SMARTFORMERS
ADDRESS: 73-510 FRED WARIN(; DRIVE
01y, 'SI ATE,ZIP f ALM DESERT, CA, 92260
PH: 760-346-0611
,INVERTERS
SB6000TL-US AC DISCONNECT
CODE COMPLIANCE
200A
ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 CALIFORNIA
PV SUBPANEL,
200A, 208V
BUILDING, RESIDFNTIAL, MECHANICAL, ELECTRICAL, PLUMBING, ENERG'
- -- -
AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE.
1
TRENCHING
VERTERS PVC + 2" EMT N
34845 SUNNY ISLANDS PV SYSTEM SPECIFICATIONS
SOLAR WORLD SOLAR WEDGE ATT
SW315 MONO 54 S6600oTL-US-22 03 PRO SOLAR RAIL 3' 180' 17.0
___]
MODULE CTY. NMTER OTY. I TILT I A... D
ui
W
Ln
ui
J
H
W
v
z
W
0
N
W
ck�Wu'j
z :D N
Q Z N
as a <
JZU'
Q � M
Z m z
�oQ
CY
(!i 00 J
W
W
H
LLJ0
> - — wI
FE N - F-
ornm a
Qw� pro) o
OUCa,Ts�t I
ZQcwfo
Qz1 r70.
aoo00r,
0Mrn
00 Q q
r7 a_ U
r.
6/29/16
DRAWN BY: BPM
APN: 767-710-03-6
1
LIOT: 1.86 acres
DWELLING: SFR,---sgft
T-1
"'
1 1
ot
I
solar module
pro solar
PV MOUNT ATTACHED W/ SOLAR WEDGE
ATTACHMENTS AND PRO SOLAR RAIL SYSTEM. REFER
TO DATA SHEETS FOR WIND AND VERTICAL FORCE
i
compress'on nut
pro solar "roof
track"racking
pro solar lower rail
solar wedge support
stantion 5/10"x6" SS lag screw
ofG
roll on com gals flashin J�it1�2"oor greater into
p member
DESIGN CHARACTERISTICS
0' FLAT ROOF SURFACE
2X4 WOOD TRUSS
@ 16" O.C. OF
BUI�-�INon
� 30
9'-0^ R C
FROM EAVE FO
TO GROUND
p
�E °ApeneT.
S�
+ r.
i.,.<
CONNECTION DETAIL N.T.S.
SECTION PLAN N.T.S.
AERIAL VIEW
ROOF LOAD CALCULATION
2T-3"
CLASS 1 - DIVISION 1 METALLIC
CONDUIT W/NO JOINTS
z
C
2
L1J
H
�
/may
`/
W
z
w
o
w
z 5 N
< j
0_ a v
o-J z v -
o a I M
z_ m z o
°
-� o Z) `ram
0
u2
to COQ
Uj
wsystern
ROOF: 54 PANELS
PENETRATION SPACING: 48" MAX
PV AREA SINGLE MODULE: 21.15 SQ. FT.
PV AREA TOTAL: 1,142.1 SQ. FT.
PV PANEL WEIGHT = 49.6 Ibs
MOUNTING HARDWARE WEIGHT=10 Ibs/panel
ENTIRE WEIGHT ON ROOF:
(49.6 Ibs, panels)x(54)+
(10 Ibs, structure)x(54)= 3218.4 Ibs
3218.4 Ibs/1,142.1 sq.ft.= 2.82 Ibs/sqft
Assembly of the SolarWedge`
Components of the SolarWedgea
easily integrate with thenew XD support rail.�;ay,n
�1'-4"
i
FIRE LEARANCES ADHERED AS
1'-1" PER ECTION R331.4.2
OF 2 13 CBC
3'-0' FROM RIDGE & EDGE
1'-6" FROM VALLEYS
HOUSE MAIN
(N) AC UTILITY
DISCONNECT
200A
(E) MAIN
SERVICE
PANEL, 800A
O
GARAGE#2
(N)
INVERTERS/SMARTFORMERS
/LOAD CENTERS
(N) SUBPANEL
200A
N ENCLOSED a o
LOCAKABLE
BATTERY BANK
d C3
o9EN
if
I
10
r
JUNCTION BOXES,
TO ARRA
I
eVrryrr
w,r `_ FUSIBLE
I
TRENCHINGif
MAIN SERVICE ELEVATION
a,y
Minn NINE `
4-1 Kt �
rdly Aserrbred
I
I
I
jj
(
63'-4"
>
N m Q
a �w Q vi of
0 oz a `r
to r= I
a
w =
Q z W ,0 , I
d in0 00 � j
o -j rn
CO
° I
GENERAL NOTES:
1. CONDUIT RUNS ARE DIAGRAMMATIC_ SUBJECT TO FIELD CONDITIONS
AND INSTALLATION CONTRACTOR'S FINAL LOCATIONS THAT MEET
NEC REQUIREMENTS.
2. ALL EQUIPMENT INSTALLED SHALL BE IN ACCORDANCE WITH ALL
LOCAL BUILDING AND ELECTRICAL CODES.
3. THIS SYSTEM HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC
SECTION 1609 TO WITH STAND 110 MPH WIND -LOADS. REFER TO
RACKING DA IASHEET.
/
{ (
I
I
4. THE INSTALLATION CONTRACTOR SHALL BE RESPONSIBLE FOR
READING AND UNDERSTANDING THE SECTION OF THE INVERTERS
OPERATION AND MAINTENANCE MANUAL THAT PERTAINS TO THE
SAFETY AND PROPER INSTALLATION.
Ww
in
i I
'
5. THE SYSTEM SHALL NOT BE INTERCONNECTED UNTIL APPROVAL
FROM LOCAL JURISDICTION AND THE UTILITY IS OBTAINED.
6/29/16
3/4" E.M.T. ON
ROOF/UNDER EAVE
IN ATTIC
GBL GROUNDING LUGS USED
PER 2013 CEC 690.43,
UL 2703 LISTED RENCHING TO:
INVERTERS
I
!
3
EX TING 2X4
RAFTERS
® 16" O.C. nJ
6. ALL CONDUCTORS TO BE COPPER UNLESS SPECIFIED OTHERWISE.
7. THE SOLAR PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY
PLUMBING, MECHANICAL OR BUILDING ROOF VENTS.
Q IG B UI S A G S T
9. THIS IS A UTILITY INTERACTIVE SYSTEM WITH AN ENCLOSED,
LOCKABLE BATTERY BACKUP SYSTEM
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
i
i
I
i
DWELLING: SFR, ---s ft
M 1
P STEM P C F CA IONS
PV LAYOUT PLAN BATTERY BANK
I i ` PV SUBPANEL,200A
SCALE: 1 /10" = 1'-0" AC DISCONNECT
MAIN SERVICE
PANEL
® 208J
PANEL
RAILS
ATTACH MODULES
STRUCTURE
PER
TO
DETAILS
2
SOLAR WORLD
SW315 MONO
54
SB6000TL-US-22
3
OLAR WEDGE ATT
PRO SOLAR RAIL
3•
180'
17.01kW
MWRE
G7Y.
NVERTO
on.
0-1..rnT
AaNUT
DC POPER RATING
tstc)
ENLARGED PARTIAL ROOF PLAN DETAIL -
ProSolar Rail
—. V 0 N C i & ^A S S O C •1 A T_E S I„ rr
i
- - T Srtvctural Engineers
C.S.FT1T:
Pratosslowl Solar Pioducts, Ind
f r 1S. Rom Avc.. Oxnard CA 03033
—l'i r#--- f.'_ - it i l
IfIII!1171f'�llll�lll
ProSolar SolarWedge standoff
(spaced up to 72'• O.C.)
t- SOLAR WORLD SUNMODULE
L Existing 2" X 4" rafter PLUS SW270 (27OW)
(spaced @ 16" O.C.) 6S.94 x 39.41 x 1.22 in
(1675 x 1001 x 31 man)
46.71bs 21.2k9)
r- SOLAR MODULE MOUNTING DETAIL
PHOTOVOLTAIC MODULES
Galvanizer! roof .- �'17
flashing
U U -r
2X4" engineered trusses,:16" OC
ToG solo- M-4100
Subject. Static load test results for the following: +
irl
AvanfingSratar
fd manr'mme
tailmumFr2ne
LD
touhaafM�YfmlSDacir`
teaeth•`O3
iHdtA•(Inj
0bs/R�
OnD►i••
Rooff6o
1 65 •
40
50
125
TEST SETUP (as sho%m In attached draw dam0: lMea modlrMt as sped C0 above, were o a 1 6'AI S'x2.b'
PAD'Mi6ml Solar Products (PSP) patented RooffraO support rails using an assembly of 511V Stainless Steel (SS) bolter
SS I w ock •a. _SM ra and proprktary PSP aluminum tlornp7 01X11ns1)rts. The RoaRraN sui)port fall Was attacl,elt W the PSP
i RoofTrucsstfudualattachimentdsvtcewth3/6•SShardvioreattburatiechmentpetals.Thesetupwasattachedto2'A6•
wooden rafters using 5/16' x 3-1/2' SS lag bolts. The attachment evens eonsWed of 48' front to teat whit stnututot ,
attachments spaced 72' on earlier, "
TEST PROCEDURE (as strewn to attached drawing detail): The Lest setup was top losderf to 5o tVft2. The setup teuained
loaded for an approximate period of 30 minutes Tho maximum deflection and ally signs of permanent deformation wire
recorded. The test setup was then Uworted and loaded to simulate the dplin condition. The teat oot up w•ao m•baded to 50
lb/ft?-The setup remained loaded loran oppmtdmote pertod of 30 minutes. The maximtan de lection and orgy sign of '
DOrmanOnl doforrnal&)n w0:a tecarded. - '
TF.$r RESULTS: ,
The maximum tap ball deflection was iceorded of 0,313'. with no permanent defonnatta o.
The maximum ufxfft deflection was (actxthrd at 0.250', with no permanent deforraalion.
This tiocumont cortifraa the Roofrrac* mounthlgs)stom used with the modules, a d specified above. withstands o 60ltjft2
stack Ilmssufo load. ettuhat tittoawind r4eeil oraDproximately:125mph". Themoumirigs)stmnperforrnedasexome
Shtearely,
lames R. vind, S.E.
mScaIDtafte"*Icon.terkeUutvhdaltuagantmtotxweed.the w4ntDofenxtlalformatuGrao7dW7te1int1arelxrt Tki zwsmi
1020*CAO 1"UN 11WO" OeferOl4 and aeaonet Wt t"11IRS OCCO i dt=b a'IM Oba 0ArWNlwdumnamco gstemt. YW}eAasKMmao
gateaaNawotetaw:rma.edb'Uattnenoon•JnrcY'e:nnlnabaetiaattcnerAlhlYnmpnrmnye•left -
IQ Mi!tl the huhd'u'e hyurta trt'.atNnarho auth.x:fdna s�'�"°� ua-09*Z Yma
%2,v reMcrkn •Roaar a7`' beet, ea ebewt b ayaed m n ap leo,:r ens the coal
e11h'POteaAfind 500 Prod. Wt r49a0.a01'cn U:f �O^��y,�• unaara�lt W:vU.
suu:twm oriAlhmrne tAa bar aratlrel a haute rn bztltrae V rCr
r l A the WOW DUOS fra',e fat CahiWa ca W A rvls' tea �+t 4]rroAn
tar rewtr:es a yle' Sabi bare. u fa the rorsx:rcWib Or the
hSIA b enrvu it tseew bUthraeet ff elAde b die ClAWWral memam a the Itof. fahve to
S=relr ouch to de mal mumms mayreulb n*a 'p to 0;0. wnt'pera0me I" a rrtad0' ,
100 mite doff MLEWCU as oa'aiai as WIND rose boa•lnaahirxtefsUc, of tDaeSucam the '
mrADNura systmymoaaDl aetr..ing frstaeN cn.
'cc accloow hbamLary tee" C.•uchmo ottaehmewa mmulgrWea by h Nenalxui5aarhtduetl
:n:em
tim�p�triot hnxcOWraty,:clt,T:kitx•,O,vJ fo..mlxM)sm r_:rc.+chsna r!::tn as. -
ttal. •
CrNete aln kNnNr aa+anddtaattr+NM M /All W c+ta oecc{ac rvavrvuHnl:.
• MOrfuroa Mem Wind wrJda tared Lrcl 6kotim am item to ut1703, a eC+'O+ntem D;e inotoed
C. Uth nnrkfevrhd 1
'wW foodnL rv::ta relan+eto defneo boa Salves Valle aa,a tool el7=,a i:2a ANtrrb:d 12 '
rntf Iilxn ar Ice 1 00 Wien li:a aterct UM s/12 tanf ICON) Brat VA last Y C"lleWl *=Pmulo C'
D•, dhlO" rn Uri 2. 64.8*6} 4'tt(IX
/.bdut0ltaetk 04.8'A 3a.a' f 1.T IVn) a
"' •E!v. sntw In.D •atioanf 25 ¢Yri+ppOad rn 2A utotr IA:tef
rhousand Oa ko, Ca 01302
Paget of 2
Module
t 8 it2 each
i
-.' AucNx2Vpax l�-
a.amora
46•
Total module (45lbs op')
2,7101he/
and rail (12lbsea.)weight: -159 Ibs
! j
Numberofattoohments: 4 ea
Weight / attachment point 40 Ibs -
(""�'(i
Area: 54 a
—�-
Distributed vielght 2.95 Ib/ n?
Li
SI16' Stalniess
Top Load Deflection: 0.313"
Stud Hex trait
i -!0 the r
5116 S1alNrss Steel
..-----"r- Lock Washer
-
—
Aluminum PmSdar
Inter-Modula clamp
r7�t\ Aluminum PrnSolar
Up lift Deflection: 0
Bell nut
2.112' Alum,num ProSolar
itoofrrac a Support Roll
- --_ _> 3f8' 5tainlass Steel Hex
C, Bol 1 t a red Fiat Washer
t
1� ._� . Aluminum ProSofar patented
I
Fasllack@ Roof Attadiment• >tr `
t}
Cl
fd10- SWuiless Steel Lag Coll
. luid Flat Washer
us te:teo cautiaal Oauchacrtts eranuraaxueaw rwicn-L"Ai Saar Drartudi ROofTracel
tw,yrrdn(;fe2darN,ilkrLaec.aW famnlacN+)ua be uacrcaNraed ai:n Doll csarsm.. Solar Modules
na;ar larw raLW ktdtcm fax -di ne, PA!exD&:IW t9t Staticloadlest illustration
Phofovaibic rond'afa antdm -
Page 2 of 2 RT 6
r Y Y Y Y Y Y Y Y Y Y Y Y Y-YYYY
NOTE: PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED'BY SEPARATE COLOR CODING,
MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMIILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS
-NOT TO EXCEED SIX (6) FEET. (CEC SECTION 690.4(B)) a ;• .. ;
NOTE: PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. (CEC SECTION 690.4(E))
JL JL JL _A, JL JL JL JL JL A A A A A A AAA A A A A A A A A A A A A A A A A A A A
' S
r
anZ
�o
%A
v
mmCZ
.017
C0 `
00�1 P
W
U
Z
LLI
QZ 0
_
J L
W
�W
ZZ04
WW
> 0)
Wa Q Q
c JZU7
L Q LLB Q M
�QI-
F--1 ZMZ0
-1 0 D I,
. I CY O'
W W 00 J
d a
X
O
� � U
0 0)Of W
m Q
QdQ(nM 0
C) 0 U Q d
l__LLJ
j
ZQLJMp
Q Z W h7.0
d0inM^ I
0 :20) I
04 J
M d _U
J I
0
W
Z
2
W
6/29/16
' DRAWN BY: . BPM
APN:767-710-03-6
LOT: 1.86 ocres
DWELLING: SFR, ___
s f
M-2
3
=03■
MC
r
f
PV ARRAY
1INFORMATION
I., f
• GENERAL NOTES: -r ':-
VALUE
DESCRIPTION
(6) PV ARRAYS 1. IF SERVICE PANELS DO NOT HAVE EXISTING •
-
Module Wattage
315W
Input data from PV Module data sheet
GROUNDING ELECTRODE, IT IS THE CONTRACTORS
(8) STRINGS OF 09 RESPONSIBILITY TO INSTALL A SUPPLEMENTAL -
GROUNDING ELECTRODE.
2- #6 BARE COPPER GROUND TO BE ATTACHED TO EACH
Number of Modules
54
Total Modules for PV system
YS
hAffil MODULE DIRECTLY NA GROUND LUGS AND ATTACHED
MODULES IffiEl TO EACH RAIL WITH LUGS a
' -Module (VOC)
45.6V
Input data from PV Module data sheet
3. EACH SOLAR MODULE SHALL BE GROUNDED USING THE '_
)-,-,...Module (VMP)
36.5V
Input data from PV Module data sheet
SUPPLIED CONNECTION POINTS IDENTIFIED ON THE ,.
MODULE PER THE MANUFACTURER'S INSTRUCTIONS '•
-Module (ISC)
9.35A
Input data from PV Module data sheet
PV® -
-
M "Module (IMP)
8.71A
Short circuit data from PV Module data sheet
(2) 96 EGC INVERTERS -
(N)AC UTILITY (E) SERVICE PANEL'
Max Voc of Inverter
600Vdc / 150Vac
Input data from Inverter data sheet
- DISCONNECT
5
verter PPTV Max Currenl
30Adc / 56Aoc
Peak Power Tracking Voltage from data sheet
89•
Average annual high temperature 'F
29'
Record low temperature F -
_ I (') #a EGC
I
Modules per Branch
9
Module string configuration
Number -of Branches
2 , 2 , 2
Module string configuration;
T I BOND TO CHASSIS (TYP.) (1) EGC "T - ''
Branch VOC
410.4V
Module Voc x Number of Modules per Branch
�N) ATTACH NEW GEC TO EXISTING
(N) ATTACH NEW GEC I Y IRREVERSIBLE MEANS _•
A;
Branch VMP
328.5V
Module Vmp x Number of Modules per Branch
BOND TO CHASSIS (TYP.)-
Branch ISC
18.7A
Module Isc x Number of Branches
SEPERATE DC GROUNDING ELECTRODE USED
ERALL SYSTEM AMPR
90.87A
630OW x 3 = 18,000W/208V= 90.87A
GROUNDING DETAIL
PV SYSTEM VALUES
OD TO N R RS BRANCH
',msp rated 800A X 120% = 960A
TOTAL PV SYSTEM RATING - (MODULE WATTS) X (0 OF MODULE IN ARRAY) (315 X 09) - 2635 WATTS
- The Sum:
MAX PV SYSTEM VOLTAGE _ (VGC VOLTS) X (B OF MODULES) X CEC FACTOR (45.6 X 09) = 410.40 VOLTS x 1.14 = 467.86V < 600V
IIVERTER MAX VOLTS, complies
mcb rated 800A + 150A PV = 950A
MAX CIRCUIT CURRENT = CEC FACTOR X (TOTAL SYSTEM WATT/ TOTAL SYSTEM T) 1.25 X (2835/410.4)- 7.26 AMPS x 2 strings =
T0A t)mt,m
complies System Complies, • the Sum did not exceed 120%
INVERTER TO SERVICE PANEL SYSTEM-SB6000TL
MAX INVERTER AC POWER OUTPUT = (MAX AC POWER OUTPUT) 6300 WATTS
`-
MAX SERVICE VOLTAGE _ (110/24OV) 208 VOLTS
- (6
/4- EMT CONDUIT
4.L 800A MAIN
(3) 3/4- EMT CONDUIT
MAX CIRCUIT CURRENT = CEC FACTOR X (MAX INVERTER AC POWER/240) 1.25 X 25A max output
= 31.25 AMPS r� (18)
(6
iHWN-2
THWN-2
(0) iHWN-2 -
WIRE CHART NEC 310.15(R)(3)(A) AGIIl9l -
X 3 INVERTERS = 93.75 AMPS
�AWG 090C = 75A x temp deratlon of 80% for 4 conductors = 60A > 48.88A. tern complies
(CND)
- --
(3) #6 THWN-2 (GND)
_
18AWG 090C = 55A x temp deration of 80% for 4 conductors - 44A > 37.SA s em complies - BACKUP - 4845 SUNNY ISLANDS
OAWG 090C = 40A x temp deration of BOX for 4 conductors - 32A > 31.25A, tem complies 1.25 X 37.5A max output = 46.88 AMPS
SUNNY ISLANDS TO BATTS '
OAWG 090C = 40A x temp derotion of BOX for 4 conductors = 32A > 14.52A, Lem cwnplies X 3 INVERTERS = 140.63 AMPS
OAWC 090C = 170A x temp derotion of BOX for 4 conductors = 136A > 125A. tem complias
1.25 X 100A max output =
125A AMP
PV ARRAY 1
1 STRING OF 9 0
60A
SB6000TL
O1 02 03 04 OS 06 07 08 09
Oa
SMA O
_, (•:
SMA
SUNNY "
PV ARRAY 2
1 STRING OF 9 O
SST
FORMER
ISLAND
4548 DC CIRCUITS
PV SUBPANEL
'
5
O
NV ER (1) B00 (2/0)
USE-2 P VE 200A"-
oc (1) #D0 (2/0)
USE-2 N ATIVE -
Ol 02 03 04 OS 06 07 OS 09Ec=
��� 1A(FU05)E
BARE CU D) O �4
W860
,
PV ARRAY 3 O
1 STRING OF 9
O
TL
BATTERIES
'
m M - ru nc na R na nn
(3) STRINGS OF (4)
PV ARRAY 6 0 i STRING OF 9
alm=wln
01 M 02 03 D4 05 06 07 OS ,0 "(3)
PV SOURCE CIRCUI `'(6) 010 USE-2 WIRE - POSITIV�BI(6) 010 USE-2 WIRE -NEGATI(6) g6 BARE CU (GND)ScN
SINGLE LINE WIRING DIAGRAM DC dFt.'Is
(6) 410 TI1WN-2 - POSITIVE
(6) 010 THWN-2 - NEGATIVE
1 (6) #8 THWN-2 (GND)
SCALE: N.T.S. (6) 3/4' EMT CONDUIT +PVC TREN14H.
20D' RUN FROM JBOX ON ROOF TO INV
4' CONDUIT HEIGHT ON ROOF
SMA
O
SMA
SUNNY
SMART
ISLAND
�RMER
4548
OC gRCU1TS
INVERTER
(1) p0 (2/0) USE-2 P
oe
(1) #D0 (2/0) US:-2 N
C.L.0
(1) 000 (2/0) BARE CU
125A
(1) 130A FUSE
O
BATTERIES
(3) STRINGS OF (4)
0
125A
MAIN SERVICE PANEL
3 PHASE
(E) 800A @208V,
3P/MCB 800A
GENERAL NOTES
1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF
THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION.
2. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE. - -
3. INTERMODULE WIRING-OURASHEATH LOW -VOLTAGE POWER, UNSHIELDED. EPR, HYP, VOLTS 600VDC, U.L
TYPE RHH/RHW-2/USE-2 CONDUCTOR SZE (AWG/KENIL) 10, RATED AT so- WET OR DRY NTH
MULTI -CONTACT LOCKABLE CONNECTORS
4. ANY DC WIRING RUNS IN THE INTERIOR OF THE HOME SHALL BE RUN IN A METAL CONDUIT OR RACEWAY
AND CLEARLY MARKED 'CAUTION DC -CIRCUIT' EVERY 5 FEET PER CODE REQUIREMENTS
5. ALL SOLAR MODULE, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED.
6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV
CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE
7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING.
IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A NEW SUPPLEMENTAL GROUNDING ELECTRODE
& LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER
NEC 110.3(8)
9. PROVIDE WARNING SIGN PER NEC 690.17 READING WARNING -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH
TERMINALS - terminals ON 807H LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION.'-
10. LABEL 'PHOTOVOLTAIC UTILITY INTERACTIVE INVERTER' AND 'WARNING POTENTIAL ARC FLASH HAZARD CAN
CAUSE: SHOCK, BURN, OR DEATH.-
11. LABEL 'PV SYSTEM UTILITY DISCONNECT SWITCH' SWITCH COVER TO BE L MVAE14-'I
TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REQ M F T N 12. LABEL BREAKER 'PHOTOVOLTAIC ELECTRIC POWER RCE'j�C\705. E
PER NEC 690.64(8)(5) D ll 11 SA 1
13, ALL MODULES WILL BE GROUNDED IN ACCORDANCE WI COOf�gtJQLL�Fy���D
INSTRUCTIONS t 1 YYYY
14. LABEL 'CAUTION' SOLAR CIRCUIT SHALL BE ON ALL CONI. REQM00110
JUNCTION BOXES AND ALL AC CONDUIT ON MICRO -IN TER SYSTEO
15. SEE DERATING PLACARD AND 'LOAD CALCS TO BE FIELD InED EI fCT FIRST INSPECTION'
16. PV CONNECTION IN PANEL BOARD SHALL BE POSITIONED T THE OPPOSITE (LOAD) END FROM THE INPUT
FEEDER LOCATION OR MAIN CIRCUIT LOCATION.
PV SYSTEM
ITEM:
DESCRIPTION:
QTY.
PHOTOVOLTAIC MODULES: SOLAR WORLD
O
MODEL- SW315 MONO, 315W
54
OBATTERIES
, BADLTP-DEKA, 12V, 25OAhr, LEAD CALCIUM DEEP CYCLE
36
OPV
200A SUB -PANEL
1
OJUNCTION
BOX NEMA 3R, FUSIBLE 1
3
OINVERTERS:
SMA AMERICA. SB6000TL-US-22
3
OINVERTERS:
6
SMA AMERICA. SUNNY ISLAND 4845 WITH SMARTFORMERS + CRITICAL
3
LOAD CENTERS (125A EACH)
OSYSTEM
GROUND
2
81-DIRECTIONAL METER TO BE INSTALLED BY UTILITY COMPANY
MAXIMUM NUMBER OF MODULE IN STRING: 09
OPERATING CURRENT:
OPERATING VOLTAGE:
MAXIMUM SYSTEM VOLTAGE:
UTILITY METER MAXIMUM SHORT__, CURRENT:
208VAC
17.42A
328.5V
410.4V
18.7A
t..,• ,I O ■ ■ AMBIENT TEMPERATURE CALCULATIONS TABLE 310.15(8)(2)(c)
avg annual high temp = 89F + 3OF for tondult 4' above roof surface = 119F AMBIENT
MAX = 89F + 60F (for 1/2' above roof surface) = 149F AMBIENT
O RACEWAY TEMPERATURE DERATION CALCULATIONS TABLE 310.15(B)(2)(0) -
/tOAWG 090C = 40A x temp derotien factor of 0.65 for ambient temp of 149F of 4 or more conductors =
AC UTILITY 26A > 14.52A, system complies w/#10AWG wire size
DISCONNECT SWITCH (E) P/MCB 800A
SMA O - 200A, 208V, NEMA-3R I" (��°DS
I
SUNNY -+ s- - Wire
ISLAND
4548 I Size
NVFRTER DC CIRCUITS I
(1) #00 (2/0) USE-2 POSITIVE 14
?a_ (1) 800 (2/0) USE-2 NEGATIVE /\ I 12
(1) $W (2/0) BARE CU (GND) (1) 130A FUSE 10
r 15UA
8
• - � 81 6
(1) 2- EMT CONDUIT ' • �. 4
ii, BATTERIES (3) /3/0 THWN-2 ,(1) 2' EMT DU1T 3
(1) @3/0 THWN-2 (GND) (3) /3/0 THWN-2
• (3) STRINGS OF (4) (1) /3/0 7H1YN-2 (CND) J- 2
1/2`
3/4"
1"
1/4"
1/2" -
2"
EMT
EMT
EMT
EMT
EMT
EMT
12
22
35
61
84
138
9
1 16
26
45
61
101
5
10
16
28
38
63
3
6
9
16
22
36
2
4
7
12
16
1 26
1
2
4
7
10
16
1
1
3
6
8
13
1
1
3
5
7
11
oume;el �
14iai1 (nunl'
s.znel fisa laj
7�a°I
IDer Ise}
)6e Is]�
ape
1 1� 1 1
-i i 31.6
rzlrsvxe
101m; IP1F]7
0_5127 0.1563
nEC
Dp9e ate
1l -m la
"iiosl
,:nan
aOUNei np
�❑z
] 1
02t&
S.Bt7
t)6�
1,72
526;
28.7
06a85
aw,i
69_��(
198NA
nr-
020a3
S.109'
L93
_41.7J
21.2
.8152
0.2a-
70/85195
U
0.1819
a82t15.50I
216
33.1
18.8 j
1,028
FJt33
1269.i
0.1620
a_11�'
2a3
253
13.3
T296
0395tf55/65(i5(
j
IC] J
W)
6). 885
60)
27)
208
105
tA3a
Oa982
10I
l�J�
e1205
13.2u,
].78-
TRE
t6.5 1F
8 )7
2.06�
0.6202
a0150(55
IOI
I
O30�
2.90618.]a
2.518'881
].1a
LgN
7
10a 1
8.6]
N
NMI`
) !
Do 6989130138700
��
eaa7
_____
Z
a
W
U
Z
W
0
U)
W
Of W U7
Z =) N
gtt,,II N
Z>�r7
a<
=t.Z U
l_
0 F- M
ZmZ(=;
J C)
�-.4-o
L0
W OOJ
Q
� N
O) Di Q
of 0
QofQNro
V) N U
Z(Wn_0
QZ W 1) t0
_j Do I" I
02M I
J
I
to a- U
r J I
10
V Z
'7/12/16
DRAWN BY: 1 • BPM
APN:767-710-03-6
LOT: 1.86 . acres
Sunmodule;, Pro -Series XL
SW 315-320 MONO
e04
i g TUV Power controlled:
Lowest measuring tolerance in industry
�o
Every component is tested to meet
3 times IEC requirements
J
iDesigned to withstand heavy
accumulations of snow and ice
J
Sunrnodule Plus:
Positive performance tolerance
J
1 2S-year linear performance warranty
and 10-year product warranty
%ftuffiv
World -class quality
Fully -automated production lines and seamless monitoring of the process and mate
rial ensure the quality that the company sets as its benchmark for its sites worldwide.
SolarWorld Plus -Sorting
Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules
that have greater than or equal to the nameplate rated power.
25-year linear performance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course
of 25 years, a significant added value compared to the two-phase warranties common
in the industry, along with our industry -first i 0-year product warranty."
'in accordance with the applicable SolarWorld Limited Warranty at purchase,
ww w.solarwodd.cotWwarr anty
solarworld.com
I � MODULE DATA SHEET
SCALE: N.T.S.
A
i
LIL 1703
C � � J`t--•I r r r
t`i, Ltiiltjr RiOdY)h
m,rdc in G.rrr,enq
Sunmodule% Pro -Series XL
SW 315-320 MONO
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STQ*
Maximum power
P„w
Open circuit voltage
--- --____ ---------------------'--`--'---'-----------
V.
Maximum power point voltage
_ _
Y•
Short circuit current
Maximum power point current
Module efficiency
a-
Meawm+g tolerance lP v,l baceade to NViMselydanrl: .: 2ak;TUV Power controMedl
PERFORMANCE AT 800 WWCT, AM 1.5
SW 31S
SW320
315 Wp
320 Wp
45.6 V
45.9 V
---------------------
-------
9.35 A
- - -----------------
9A1 A
16.03%
1628%
'STC. 1000Wtm', 25'C. AM 1.5
SW 315
SW320
Maximum power
P,,.,,
240.9 Wp
244.4 Wp —��_-- -
Open circuit voltage
V„
39.8 V
40.1 V
Maximum power point voltage
V„K,
33A V
UA V
Short circuit current
I
7.77 A
7.82 A
Maximum power point current
I
7.18A
7.18A
Minor reduc tlon in Pftxwmy under partai lad condrtionsat 25 "C.at2WWim-,100%(+i-2%) of the SIC efficiency i 1000 Vin ')nachwe d
1 1000w:m
DIMENSIONS
COMPONENT MATERIALS
800 W/m,
Length
78.15 in (1985 mm)
Cells per module
72
Width
38.98 in (990 mm)
Cell type
Monocrystalline
6W W.I-'
Height
1.81 in (46 mm)
Cell dimensions
156 mm x 156 mm
? 400 WJm'
frame Clear anodized aluminum
Front
3.2 mm Tempered glass
Weight
49.61bs (22.5 kg}
'EN t 2 t 50)
-
200 W: n r
100 w1m'
�agxrvl V>
All units provided are inpenal.51 units provided In parentheses.
SolarWorld AG reserves the right to make Woclhcation changes without notice.
THERMAL CHARACTERISTICS ADDITIONAL DATA
NOCT
TCt _.
TCV„
TCP
46'C Power sorting •0 Wp/+S Wp
_. -.._ ....._._ .--.....___ . .._._.................. -._.
0.042 %/K }Box IP65
-0.304 WK Connector KSK4
.0A3`967K Module fire performance iUL 1703)Type 1
PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION
Maximum system voltage SC II / NEC 1000 V
Maximum reverse current 25 A
Load: dynamic load 113l64 psi (5.472.4 kWm 1)
Number of bypass diodes 3
Operating range -40' C to +85' C
0.61n. I ISmm;
I.a n.(4cxnm)
0.98 in. f2s—
SW-01-6056US 11 2014
4/1/15
DRAWN BY:
BPM
APN: 767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---s ft
D-1
5
NOW AVAILABLE FOR 240 V j
,
xf R61C&US
Innovative Economical
Reliable Convenient
• F.iu kansfomyrrlesx SMA inverter • MORimum eRw:ency of 98.7 .
• C"Cuiif- oc6w remyernh+n • Iriogrded DC &K—eci
to be anihnd in occadorce C —6c dng CK Y ci 98 5%
m '.9 rnent • SMA Power 9doncer For 4 ,—
UL 17A I • Sf pertrx MPP trrx:#ing M•h
oinm grid cnnniian
• F.rstk"•ew ,6a,louecttcueirg,, cP%Tra2''+
m;'w listed occcirrrg to A ! 6M • Tiomfo-cirloz, wish HS npoksgy
SUNNY BOY 6000TL-US / 7000TL-US / 8000TL-US J
9000TL-US / l 0000TL-US / 1 1000TL-US
Trans" I-nerless design,-noximurn energy woduclicin
The Sunny Boy TL-US series Is UL listed for North America and features SMA's innovative H5 topology, resulting in superior
efficiencies of more rhon 96 percent and unmatched color power production. The tronsformerless design reduces weight,
increases the speed of payback and provides opt -mum value for any residential or decemrolized commercial PV system. The
Sunni/ Boy TL-US series for North America is the ideal choice in transformerless !ethnology.
INVERTER DATA SHEET
1 SCALE: N.T.S.
Technical data
InputfDC)
Max usolife DC power (0 cos y - 11
Max. DC voltage
Rated MM. vohoge range
MPPT operating vohoge range
Min DC voltage ,' start voltage
Max input current / par MPP tracker
Number of MPP hackers / stings per MPP tracker
output IAC)
AC nominal power
Mnx AC apparent power
Nomin, t AC vohoge / odi:rslable
AC voltage range.
AC grid frequency; range
Max. output current
Power lim" (cos pi
Output phases / 1,n. connections
Harmonics
Max. efficiency
CEC efficiency
AotKrion dev,cls
DC disconnection device
DC reverse polarity f(oteclion
Ground fouk monitoring / Grid monitoring
AC short circuit protection
A&pofe sensitive residual c,nent monitoring unit
Air lmh circuit interrupter f.AFCi) compliant to UL 16998
Protection Anss / overvolroge categaiy
General data
Dimensions (W / H / D) in min ;ia)
DC Disconnect dimensions fW / H ;` D) in min (m)
Packing dimensions (W / H / D) in rim 1rn)
DC Disconnect packing dimensions (W / H / DI in min (inf
Weight / DC Disconnect weight
Packing weight / DC Disconnect packing weight
Operating temperature range
Noise emission (typical;
I"Wnaf eansurriptan et rght
Topology
Cooling concept
tectonics protection rating
Features
Secure Poway SuPOY
Display: graphic
Interfaces: RS485 / Speedwue/Webconnect
Warranty: 10 / 15 / 20 years
Cedilkeses and permits [more avoiloble on request)
Sunny Boy 4000TL-US
208 V AC 240 V AC
4200 W
600 V
175 - 480 V
125V-500V
125Vj150V
24A/15A
4000 W
4000 VA
208V/• 24OV/•
183 - 229 V 211 - 264 V
60 Hz / 59.3 - 60 5 Hz
20 A
I
If2
<4%
Accessories
I Sfvad.K.e:'Waecurowa I S485 w4.6.
- vrertoce DAr-aBSiB{4510
SWUrA.USr4
• Standard lecture O Ophonof Peon rc - Not available
Dwo c r nominal cand6iofu
Sunny Boy 5000TL-US
208 V AC 240 V AC
5300 W
600 V
175 - 480 V
125V-500V
125 V / ISO V
30A/15A
2/2
4550 W
5000 W
4530 VA
$000 VA
206 V / •
240 V / •
183 - 229 V
2) 1 - 264 V
60Hz/59.3-60.5Hz
22 A
I
1/2
< 4`6
Sunny Boy 6000TL-US
208 V AC 240 V AC
6300 W
600 V
210 - 480 V
125V-500V
125V/ISO V
30A/ ISA
520O W
6000 W
5200 VA
6000 VA
208V/0
240V/0
183 - 229 V
211 - 264 V
60 Hz / 59-3 -
60.5 Hz
25 A
1
1/2
< 4%
96.8% 97.2% 96.8% 97.14,' 96.6%' 971%•
96% 96.5% 96`ts 96.5`F; 96%' 96-W
•
•
•/•
•
•
•
1/IV
490/519/ 185 119.3/20.5/7.3)
187/297/ 190 17.4/ 11.7/7.51
617 / 597 ; 266 f24.3 / 23.5 / 10 51
370 / 240 / 280 114.6 / 9.4 / 11.0)
24 kg f53 lb) / 3.5 kg f 8 lb)
27 kg (60 rol / 3.5 kg fa lb)
-40'C _ *60 rC f-AO'F . +I40 "F)
< 25 dB1A)
< 29 dB(A)
< 29 dBf A)
I V:
<I VV
,1W
Tronsfomfedess
Tronaformedess
Tronsformeifess
Convection
Convection
Active coaling
NEMA 3R
NEMA 3R
NEMA 3R
•
•
•
0/0
0/0
0/0
41/0/0
0/0/0
0/0/0
UL 1741, UL ) 998, UL 1699B, IEEE I547, FCC Pan 15 iCbls A & 51, CAN/CSA C22.2 107, L I
' Niskininmy data as of February 201 A NOTE: US --"m strip with gray lids
Type aeugnonon SB 400071US 22
Toll Free +1 888 4 SMA USA
www.SMA-America.com
SB 500011.-1S22
SB 6OOOTL1l5.22
SMA America, LLC
` W
W U
Z
W
LU
to
w
(n OfUj�
Z Z N
N
a-
Q
0 M
Q d d-
Q JZ"-
p Q t- M
w Z M Z �
Oar
L1J w(aQ
z
1--i w
H
O
��iJ
U J W
rnm Q
aof
0UUQ<t
2
H Cr U
Z Q (r) r- O
QZW to (0
a0000r,
0 M m I
00 Q z*-
n d 0
� J
0
W
Z
2
N
4/1/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---s ft
D-2
6
SolarWedge TM
Revolutionary Commercial Mounting System!
SolarWedge by Professional Solar Products, Inc, is an innovative low
profile commercial/residential PV mounting system. The system provides
an easy to install and economical solution for 5, 10 or 15 degree
structural attachment. SolarWedge' integrates with Professional Solar's
patented "top -down" commercial RoofTrac and Foamlack' stanchion A
products. The system dramatically lowers installation and shipping costs
while optimizing installed wattage on the roof.
Advantages of the SolarWedge `
Easy handling and Installation: Each box supports up to 30' (front
& rear) of Roof7rac ' support rails
Integrated Leveling System: Compensates up to 2-1 /2" of roof
variation using an included 1/2" x 4" stainless steel stud
Fully Engineered: Load tested to 30 lbs. per sq. ft (approx. 110
mph wind load) at up to 6' centers
• Finished Aluminum Parts: Clear anodized angled support
brackets match support rail. Foamlack ' stanchion parts are
machine tumbled and cleaned to provide excellent bonding of
foam, Flash or
SolarWedge'
Precision extruded angles of anodized
aluminum compress the support rail at
a fixed angle while dramatically
increasing the strength
Leveling Feature
Stud rolls into the post up to 2-1/2"
to eliminate the need for cutting studs
on the job
f. Foamlack `
Each kit includes the Foamlack "
with a 3" aluminum seal plate.
Size included depends on the
angle purchased
Roof Surface
Modules are msauntrci in
the kllustrated direction to
optimize performance in tttr:.
summer months
ATTACHMENT DATA SHEET
i
SCALE: N.T.S.
Assembly of the SolarWedge
Components of the SolarWedge'
system easily integrate with the
l new XD support rail.
.oaa iesten 1 Jam Nut;
110mph t/3Hwaxt,r:
14'd load 1 ct3rYls:t-
30 lbs. sq. ft Nt,i 1
At 6'CM Centsv `.. �� •. xD
Rail Insert -
Compression Nut
1 /2" x 4"
Leveling Stud+,.
Na11 Low
Support
Foamed bajses
as illustrated
t : i —Lower suw L -
Jain Nut
Jr --
/ tam Nut'
Fully Assembled
Attachment Parts List (Per Box) Not to scale
Shipped in a shoe box sized package, the SolarWedge XD attachment
components offer easy handling and storage along with reduced shipping
costs. 12 ea. E`> 24 ea.
6 ea. �j Aluminum 1,2" SS Flat Washers
Compression
1" Dia. Aluminum Nuts
Rear Posts 12 ea.
12 ea. 4.-,� 3l8 JS Flat Wmhcrs
Q 6 ea. Aluminum
Lower Rail
1"Dia.Aluminum Su its 36 ea.
12 ea.
Front Posts a. 112" SS Jam Nuts
112.. x 4" SS
12 ea. Leveling Q 12 ea.
IS Dia. Studs 3" x 3" Aluminum
Aluminum Seal Plates
Rases
Attachment Box Dimensions _ \
Specifications are Each box contains enough
iubject to change attachments to f 6" —7
without notice. install up to 12"
3.3 kW,,
Standard SolarWedge Technical Information "`� �°"
[hmensions
> Load Tested and engineered to 30 Ibs.Vef*rox.l 1 Omph wind load llustrated
equivalent}
> Utilizes FoamJatkaboratory tested to 2,870 lbs. vertical and 2,615 lbs. side
lateral pull out using a 3/8" x 6" tag bolt (secured at approx. 6-1/2").
I
51, 3.3 kWnc. •us,,y 1IG W ;.
Lmodules
> Structurally attached to the roof - extremely important in areas with -
potential horizontal and vertical seismic movement such as California.
> Available in'$1(Y or 1 T angles. Optimized to help reduce typjcah
peak summer demand charges.
Front Extension Heiight
F
All Angles _�.r—�-'_----------------B�I12'+/-3/4-
4' O.C.
Rear View
Rear Extension Heic
15 Degree
19"r/ V4'
10 Degree
14-112`+1- 3/4"
5 Degree
11"+/-3/4"
'rteksht from footsurfat-,w 1
bottom of support raii
2.5" Support Rail
product and purchase inquiries contact:
eCO- I C T 6' Span between
attachments for commercial
--- construction only
CLEAN ENERGY SOLUTIONS
www.ecodirect.com l'i """ "` 6' O.C. -- - - ------ -- ��
Drill GtJide (Sold Separately)
professional ($05)486-4700 Three Sizes ..
SOLAR (805)486 4799 fax • `s eta ' s r
1551 S. Rose Ave. 1 . t . •
ree Kit)
�71'C}C. uctS. t3xnard CA 934J33 Degree The FoamJacWrill guide ensures that
'3 www.prosolar.corlL pilot holes are drilled 90 degrees to the
Paten1-636o,491andoS4/262 rafter/beam optimizing the strength
swzooxo322 and appearance of the connection.
1—
w
W
v
W
w
_
cn
W
Ofw
Z Z N
d W
Q
g>a in
Q
� d Q �
J Z U 7
dl�idM
z
d i—
w
Z coZ 0
LU
G
J O
't C,
_
Ln
�00J
U
w
Q
Q
II Q
=
w O
I
> U
o w
03
Q
Q Lj
Q i11 M
ODUQ`t
n 1J
U
=
W W
1
dZWMC(o
oocor-
Nto
J v
n
U
d
� J
I
0
rn
5/14/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, ---s ft
D-3
7
Roof Tris `kdr.ttttt/''... f3t.ufstr,(1 �4 rlr ,tro ;'� t(/rFtCpr:r+J`
ac
ftikl "T,-,.4Ukt; cM kktli AjIMA011 ft
The Original "Top -Down" PV Mounting System. ftw_ MIWO� ME 1'00W' 6ft*1A-n hAZ alki ittiblig r-.4i, Vrrar
Thp-*vAAd rmb & nk nra,- a9quT vA-r vppori nuk
a4kx44k.? o.)w4omilefi?t untyei m4i
I J1,
L, v &x i& 4e irzk7l
dtAxhNM1 RUNIkd1l WAVUhn no me
W 7- pwanmg A*W.
W01 *1KT & k&t JOM - "COW WOO
pw" V6,160,4" & 04160 Ptm% peroals.
Tat Ttck potscmd 1000 P*WM SS,b�b„G4A.
&Y*7r, AhtftxtAstmis
& ATW t_1j_ _014a. "MMON on 4.` cV--xd1 alwwnum is juib- anwhed P,,
xnPAto, m4albk ftm:467awff 4kT#kjhM_
.1 WY It 1W oftr 10 sq. iwAff
db" lopmtw damapk, Alrah,
,1V.qWAjf; sbiligius
Fully"
t0wXy chikges The Iniddrat pr4eto of The
alumvium chan&4 Pkiking dzotscantlyft?W
Ibis 4NIgn aUs zkir makiks b be vadkd X a kvvr
prq�L- to & mofprrA idmg a more a&sA*aAUv pkuw�,e,,rFsKrxtkatxorl
Mbdule danoare _"xjfxnqvk.,qsw&1. eAftdd and
cknippipi-4mipronikv inuardimn,,in on The nhAbAr
frame -*x unng the kimipkde in The ficame
ATTACHMENT DATA SHEET
�j�SCA`LENT S
1%J Integrated with Fast Jack`�Iattachments
Roof Trc3c Aepa&&W Roofer r4an nztaffal ttVb *,FaVW*1
tAirtnuint me"pmn as im kikil mijifton for rm*dk9ibtu
The Originat "Top -Down" PV Mounting System. whm ajk*ng & &raf W Fasliackk is akvo the vlar indidW
prtf.wd #ktW of t&Khn tid for nff amwitajon rrx4s
Roof Tr&C$r, P Fag JaCk" piotrtm uncle;
Patent 26,360491 b, othei ports pe, KA",
Tile Tla,-.'4 PIC4Vt101- WIRI P-11VIt 0516446TO"L
XUO"abof v is biv, ffie Fist Ar
isUbmint ftuatkzh- b&Wuld u* Ambdri, v LTorAwL-1
&, PW Trw - mounivig syskm. arifti the sAAW rad kwftan
dud&yvakv 14ieidt'OR z1ar arn'tv I
' 830) 84-SCLAR
SOLAR�6 Cabe Chietzal
Qmar€o, CA 93012
Splice Kit
7be,Phte kk; a "u&n k) rig dly lock midliple rad
iws ajiwhiry lbee a&rspr /hr-
#kjl qQbe nw& m1fixvitkipwiging
tt,e roop,,P!
For inure injbrination you
caji viql ads on Ibe uvb at
MIYU7U.I. Roqj-frac. coin
cad" tvitatcbmem
ridick tvid mr(AW
wkvc Our I't-vemed
i &e bok directh,
chictri, t.� w where if
k4 wip/W)Ft ibis fiv,1-
(IV
Gaff xesfla-iMp, io
r The ik" u lUmn
'twomfinp owlp.Ki-
>L,J
� CN
0 CIJ
U-1
jj
<G:� <
_J C-)
00 <
Ld <
z (n 0
z
< L-1 (D
a__j
U M
00
v') a- L)
LLJ
z
2
V)
5/14/15
DRAWN BY: BPM
APN: 767-710-03-6
LOT: 1.86 acres
DWELLING: SFR, - --s qft
D-4
8
Taetwca! data
Sunny island
.5" US
Sunny IdmW
60" us
b s
�s
AC mulp t lloadsl
I■
kaod 9eid •r i ! A,C w%Mapi targe
120 v! 105 4 _ 133 v
1201r'!10:S v _ m v
P 1 °
Rd—d keai r! a---y 1-4p ia4u-b6i
6010/i5 Ke ... 65 Ha
60-- HzISS hia _- 65 rte
x
AC ewer Heat 25 "C { em 40 °'C:',+ km :3 houn
Rc�ori p••xwar 16 u,� I—! 25 t ` {i cpm � - 1 I
AC power ai 29 *C for 30 nnrn ! I mie / 3 s
30WWWt 340(: W
4�519 WV
53W W ! 94M W! t low Al
0+. w w/5Ur5i9 W
ST #�9 W�
70M W! R W/ 11w W1"
+ -J 1",=
-"
Rated C—aw ! — ruts a r-nxn 1p-Ai
37.5 Aft BOA kw appri:. do ez
48
AP 80 A kt apprrwr. 60 rra
CZ
Ad t�vrrortr'kida i txril;.t v 4kglo j p &.," tr j.N wk*, rid t
3 %! 3 ... + 1
3,X ! .1 ... + [
Z
A1: input JPV aff*y or grid!
ROW inpui wclinge ! AC::riput ozAagnr r-unga
120 V AG'IV - I my
120 Mf 60 V - 150 V
Road k+wi rrw wr. y e ul6 w,ek,.1a input �,&#mn y ny0e
Matt. AC bmut cwn A f cjit ij a
60 t ft/54 P& ... 66 MZ
56 ,V0 A — SG A
60 KV.54 ffx.. 66 fir•.
54 " A ... 56 A
reiraar►
Muir. ,kC ftwui stc-vr'e
Maslary OC inpul
Rdw input .cltisga % l3C .clrsRe rc, a
Ms2k. is ,ftry 0.;.,,,tptV ur-ere / DC r,:rvi ch rgkV curawt
Brsrery hne r ftc'*oi!r=apecry t--*err
i.}ecus3a rxrvui
rs3.kw
48 V/41 ,v _ 63 k'
100AISSA
tna4, ldiCd f 00 A% ... tOCOO.0
lug,[,arge pr ,;*dwm wth rarlanxrtic tut
chorpe ix"*.d aytint nagxr eh"
67 kW
a8 i7ld f y .. dr5 k
l 34 A { 1 t O A
1wd, Nk-d/100 Ah - 10000 Ali
P-W drerde Prcamr wM vrel r
charge artd eqw lulasart rj't�
-
----
W
W
=
Ul)
Q
Q�.044{24.1/93W11
Uj
w
z
F--i
Uj
U
z
wp
rn
w r[i
Z Z cv
<
Q�a
UCRr.mrrhs;V#14
�z
o a Q M
Z Co z p
J p D r
Ci
M Q
J
w �
Q
w
�
lself Ct771Suffvt1ttR S
Au. awki cy/Ckc*W.:J ecyr 9d'Ad'441 949t/94%
.`atif-ConA SPrian W14> . Soc+al 1 *vftd yr 25 W/4 W 75 W/4 W4
PraAmclrra devices
Dc Keverm pn�t!y prat on { M fuse i ! i i % i r
AC shor-efc .r / AC �•.at%c d i ! i at l i
• i CA,* ten**utu'a ,t L. 46t`s coop drxha" i! i 0/ i
t Genial dale
01 dd7lb12{235mm 4671612l235 mm
Ii8df24.)lW.3-
Wok* 63101139 fb 63 kg ! 09 % i
C*Maests3teatperq%X*runos .25 C _. 4-60 4C1.13'h... 4122 •p - 5 °C... #601Cl-13 `--+12,2 xp €
Featt"s / i inrtian r
r atsoa .rmd dzplay / is eoksy 1e omd ! 2 iniarhal j 2
_:.. _ . m ., ..,_ >, Cy ae ae peo�ck-N fau wdo* sD AC 605,19) ftvElt+i4 1 A nrt� ors t3 IpMA t 1 �
T x yhsse sys»rrts l Paulal a*v4r:4Ln
tnkiyt+iertpcits ! rruhi5�,sier opw�aia7n .. f i _.�- i
Shute kF ct►:tryjr exrlukstiar: ! ?ny4 tltt�ri�e ,r eCurdist�n i ! • ! i i ! i ;{ i �
In tLA.ar ss,^^ 6kie motor ,a y
bkl ! !�` 1 i y` i i{ i
-
&,°fairy tcna-ahttu sat.sat {. aki C, t66
I
;: hA,aretsnb' S�' Siw49-3akr
tyertfwa9as cru aupro.�h wow 5JM- $dar .ccm
Acasssaritsg
I
I
Efficient Simple Flexible Durable
• ma+imum ACMnty C496% • [my oammmorn waft iFsr • For Smry Isarrr iyaerr.i from d.5 • Ewa avov,,,d capab,.*
• CEC .lhr oxy of 94.5% end94% 'Ovd. Con*rdwv) Guido' W 100 kW • optiC001w, add t * ;peraturo
• 5icre of ch0,ue ,attar • Compute a*9rd maaa "Mrt - Sinrgla, sp itp msn w4 P.-cocFrma mmape-W, rysiam
• i=roli a b&Wyr mavragamtrni • EAcge" to Q d hat b vary cf*n1,k i .' fvwKk"a us porafel • Svax aardcrti man? y
fw ^axums* bcftry Itto ba,: .p --d madlar}y w9-dubw
• AL wrtt DC crr rslw g
SUNNY ISLAND 4548-US % 6048-US
The prf•cent r-+1 cr d rn rq,-e°r
Nvwf cam* r" bcAt fry hd*
lrAta — IRS Oda f' MuK-JjA%r PSI
Ctcleu� itca° •GanMvn'
L' r4 .�dirlq
i Sfsin9krel kctwr 4 Ctp rr.,tiest►.rc-?liiuraiialr;i
Type r rraigrn#twt
- r— r- — GC
At
f 0
0/0
0
0/0
M .54611s#4
�
010
w"". ! Q
e
0/0
S 48-US-10
.�
-
--
s
w o I
N H
Q w rn m M ao
CY I
(n 0 c) Q ; I
N = U I
w = M
Z Of
Q LJ O I
Q z w M r,
w
o�rn
N J
M a- U -
Me SMA Sunny Wood 4546-US and 6048-US inverters are based sir pfoven a*t-orrd technology and fea=ure industry
le-ading power r?rxtpu!.1l maximum eHicierst y of 94 pertem ensures peak production, wl4iCl5 gestalts in rgtlirG+rtf diesel usage
.3/23/16
DRAWN BY: BPM
APN: 767-710-03-6
in rural communtit es. More flexible sizingabcws for sim plied s seem Lanni A . witl+multicluster technol
p Y P ' °g'v, up 12
Sunny Islands can be in'egrated irio afi-grid power syvems. up I € 0 krY iri size.
t
` -
.v_.. i
a;
j IL
.:w... __.._.,;
a
LOT: 1.86 acres
DWELLING: SFR. ---s ft
•
�Ivme-ptt•.esa iys�trt
_ ��:t,��� iyi�..
w-_ _
_
D-5INVERTER
DATA SHEET
1 SCALE: N.T.S.
9
GROUNDING LUG DATASHEET BATTERY DATASHEET
&1
HelioLug
The UL 2703 lug 8A8DLTPmDE
only certified grounding on the market.
CZ
C
HEL_IOS
Included Components: N_
1) Lay in lug (tin-plated, solid copper lay -in lug with a stainless -steel set screw) SCCTI�S valve -Regulated, Absorbed Glass Mat Technology
2) Stainless star washerCL
3) Stainless steel bolt
Nominal Voltage
4) Stainless serrated lock nut ' g M 12V
`
Capacity at C/100 250Ah
care r �S� � ✓ i
;;'
Capacity at C120 245Ah
Z
✓r
a �,s , t ! Weight 163 lbs. (74 kg) ry ..::
Plate AilaY Lead Calcium
Uj
t
=
w
{ Pasta Forged Terminals 8 Bushings
—
U
� ? �
Z N
_
a
z
Container/Cover Polypropylene"Wii
Q
a a �
Operating Temperature Range
._....._. -40F (-40'C) - 140°F (60°C) DIMENSIONS
1_
Uj
a-
a Q M
oQ� .
z m z o
QD
i
J ,q
— For Charging Parameters please refer to Length 21.03 (534 mm)
in 00
y www.mkbattery.com Including handles
1 2 3 4
LU
w
Click on Technical Data. then on Photovoltaic Charging
HG L U i Parameters in the PV!Solar section Width 11.00 (279 mm)
Z
Punf.acf Li-- P<tvjw:r Type A,.pravak PaCKMW,
- Height 10.82 (275 mm)
1„
w
2
I --
Hu Hs gs GrCLnd ny P.odaLYs Mdw4j
Vent Self-sealing Including terminals
t.! ,oho AGz AGM CA19 Lail n. D40n of Disewrp r, •:5'C q7 Ff
Ssa.d o^. @Cf 2 zov C�frac•e
Terminal T(T975)
INSTALLATION INSTRUCTIONS: _ = ::.-
• Place the lug to the designated module grounding note with the star washer between the grounding lug and --- ------�•-• --• -
w O
> - U
� N W
the module frame in order to break through the anodizing and establish electrical contact with the aluminum.
to c
Torque the bolt and nut to 30 in-lbs. NOTE These Instructions provide guidelines for general use. It available, — - ---
Rated UN2794 - Wet, Filled with Acid
¢ � In V
< (n
the specific module manufacturer's instructions for the location of the star washer are to be followed.
_J
o a
Made in the U.S.A. by East Penn Manufacturing Co.. Inc. — _ =_ _
_ ~ I
• For the attachment to the racking, slide the bolt into the mounting channel of the extrusion or into a %'" hole — —' ^ ✓-
drilled through the extrusion. Place the star washer between the racking and lug and secure the nut and bolt Distributed by: y —_
z z N o
Q — w "' cO
r— E -.c._ ..
to 30 in-lbs. NOTE .. I _ _ _ . _ _
J p 0 00 r
a o � rn
• Insert a 4 to 71 AWU copper wire into the lug and tighten the lug set screw to the copper wire to the torque] fi -i
00¢
° J
y
based on the wire size. (4-6 A WG at 35 in-lbs and 8-12 AWG at 30 in-lbs). Do not exceed the maximum rated
overcurrent protection, 20 A (12 AWG), 40 A (f 0 AWG). 90 A (8 AWG), f 50 A (6 AWG), and 200 A (4 AWG).
Z
0
Npp- 6Pee"fc+lax cr• s'dian N .'a. }u -r.aN mHta. CC=Mw . —I A110 1q; C— 4- Sa x d+ b " a� spmclunaLms. A. mMe+n.mN..+W- aiun aM tla VT- Ww.n x*9 bile+W b !W mcu� W n-d ra�+oa bN n. peaee�aru
•wu:WxanxN,VM'fficyo o+OonY•>Wea a+vrM e+i:.+aM d m`ShtWe�gev>er p)W_cmr 7m Aa.wMw+M'+�.�e ae.ne6a rannyt +Mw.+.reasay. i 1nw.11 °s"r.0 o1—a.-W, p,.re s•e v. nv 7F .�
.9ccr+eN+OmOMb-*-'r yFw. TYe .•ark afN. Pa .. w.1r L•M.YNWroPatc •+r zp.N 5rxe.•c.eau Y .:r -v +a^w>Ia z�..r.ema �r
MK Battery r�
V)
3/23/16
DRAWN BY: BPM
• • 1631 South Sinclar Street � Anaheim. California 9 2$06
{
APN: 767-710-03-6
• a b Toll Free: 800-372-9253 • Fax: 714-937-0818 • E-mail: sales@mkbattery.com
LOT: 1.86 acres
[)WFI.I_ING: GFR, ---s ft
• '_: .`` '
its Swt*ti to Change ""Mar -41WI B. NO bast of t,ri5 fM Go.��ed ar rFPfP'n^.sss+w, llk�rC+uCatty V m►r tranmafly. Mlrf A wntc" permrSsian Nora'tw Company- C2015 E.W oaae"
D-6
COMPONENT DATA SHEET
1 SCALE: N.T.S.
10
aim
f�
Tedsneal Data
stina4mmer
General data
Number of phases
Ruted wiage
Spltphcw
120/0 V-
3
AC voltage ..W between. L, and N j 1, arxf L,
Riled Frequency
60 -L
Dirrcwiom (W x H x Dj / Woighi
24.02 x 24.02 x 9.25 in (610 x 610 x 235. man) / approx. 123.5 lays (approx. 56 kg)
ersRRrr
Ae power consumption
19W(typicall
Nominal power tronsfomcr•
3.A kVA
ACpower !romformer for 30 min / 1 min'
4.4 WA / 8.8 kVA
Max. effirierW/f.EC efficiency
99 A / 98.8 A'
`
Honk rp access
Knockouts: top 2x 3/4'. 2x 1'. 2x 1 1/4" bosom 5x 3/4', 3x 1. 3x 1 I/4'
Y
a U
Connections for Sunny Island
'
-
X�
Mciamum number and Ramapot voltage of Sunny said
I x 120 V 0.1. N)
V,.
a
gated porter
7.2 kW
VMW GLUM
Current at rated values
W A, 60 A
Fuses
1. mnlatuse ctrue breuker K60A to, AC2
z
PV plant connection
Number of connectiuns/ nominal vukoge
1 x 240 V ILI, L2, N)
L
! ,
U
Z
Rakd / AC
9.6 kW / 6 kW
-
LJJ
Ld
parvar power ut yrtd purold vpardion
w
Q
` ..
AC cenent at rated vducs
40A
W
3k yx, `
usos
2 x mintossre ci,cue Fxoakor ZSOA or 725A, aduptobb
Of W
Load connection
Z D N
Number of connedionsjnonisal voltage
I x 120/240V(Ll, L2, NI
Q
Q W
Rated pot r / AC pnwer at 40 •C
7.2 kW / 6.6 kW
¢
Rated power/ curnw between 1, and L.
6.7 kW / 2S A
Q
0-Q
Rated power / curteni between I, andN
3.8 kW / 32 A
Q
Z U 7
W
Bred paver/ Curren' baNeen L andN
..
3.4 kW / 28 A
�
Q Q r )
Current at tared values
32 A 28 A (with activated bypass 2 x 48 A)
�,'i',
Z_ M Z �
-
Grick�generator comedion
2 x K40A (wihaUvoted bypass: K60A)
-� O t�
Nuerber of cuntxxlionsj rxasnkw) voltoge
I x 120 / 240 V ILI, L2, N)
Uj
W 00 J
Riled grid input power
11.5 kw
AC (rpul current
2.48A
Z
Q
q
"y - - a •� a'�
Mnbiont cendAam
2xminidureeimitbmake,K60A
L--t
2
-
Oporoing Io peraturo,angc
.13 *F.., +122 'F (-25`C.-+50•C)
t—
�....:
F
A:w ki—icily
Cefihcnhon Grid pe mih
0 -100 % ( mnurxfensing)
NEMA Type 1
UL 17l1
I
C�
Features/funefion
Warranty: 5/ 10/ 15/20 yeas
e ! O / O / O
`ntegro!ed bypass for malnfergrsce/laadsherifLr,g relay/transbm:er
prouctbn
/* !•
W O I
Simple complete Efficient Safe
o N
Q
m
• Pre-w nod AC di orlbuAon booed • Itypon swatch fw d,red • Mmirm a elf ou+cy of 993 • UL cerllxd
�
M
0O
• fcsst roglksion oral grid operator Highest yield coot i-.e entire power • Cptw,uert werkad prarec11—
canmrsioning • Load shrdding relay to "ar'm
prevent deep battery dactnorge
`Po wet t!wt can be Iremlereel ham one leg to another
JO U Cn d.
2
• K"L,e a,n,4 hreaker•. 6, PV
•Standard fedurw O Optoeal (eatums - Nsa ovo'u'able
W = Cr
Q W
anal kxsd
Typo dec�gnation
- SITDBOX-10
Z V) p
r m I
J n n r
LL
P,Aemafc Trewlu Scorch
SMAR FOSWEs (ronarormm aril dusrb xonpwJ
N
SMARTFORMER FOR SUNNY ISLAND
`oil
Spfif-phase stand-alone ��ics—I}L�vv case: I-I:_�t everLLJ
RrI••"'
the Smortforrner is the complete solution for off -grid and battery back-up systems up to eight kilowatts. It acts simultone-
!
"i
U
ously as AC distribution and a 120/240 V outoformei. The outoformer provides step-up and step-down options to supply
U)
loads with 120 V and 240 V using a Sunny blond and a Sunny Bay, with high efficiency over the entire power spectrumC,ab
Thinks tithe pre -wired bypass Function, the PV system ton be easily bridged via a robust switch for maintenance The opti•
- ice. 1
a.a•t
Pam"
6/29/16
DRAWN BY: BPM
mized tronsformer overload protection and a load shedding relay ptovide extra protedion to the system. The Smartformer
makes the stand alone power supply simple and reliable.
n,
l
y
APN: 767-710-03-6
sum•, s•.,�.
LOT: 1.£36 acres
DWELLING: SFR, ---s ft
Ord
Toll Free + 1 888 4 SMA USA
D-7
1 SMARTFORMER DATA SHEET
SCALE: N.T.S.
www.SMA-America.com
SMA America, LLC
11
F7
JUNCTION BOX & CONDUIT RACEWAYS
NEC 690.31(E)(3) — CONDUIT / ALL JUNCTION BOXES
' WARNING:
-y r
'PHOTOVOLTAIC POWER SOURCE
NEC 690.35(F) — UNDERGROUND SYSTEM JUNCTION BOXES
WARNING:
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNDERGROUND AND MAY BE
INERGIZED.
DC DISCONNECTS
NEC 690.14(4) GROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
DO NOT TOCH TERMINALS.
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE
ENERGIZED IN THE OPEN.
POSITION.
NEC 690.35(F) UNGROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNDERGROUND AND MAY BE
ENERGIZED.
NtG b9U.14(G)(Z)
PHOTOVOLTAIC
DC DISCONNECT
NEC 690.53
1 WARNING PLACARDS
SCALE: N.T.S.
INVERTER
NEC 690.5(C) —GROUNDED SYSTEMS
WARNING:
ELECTRIC SHOCK HAZARD
IF A GROUND FAULT IS
INDICATED, NORMALLY
GROUNDED CONDUCTORS MAY
BE UNDERGROUND AND
ENERGIZED
NEC 690.35(F) —UNGROUNDED SYSTEMS .
WARNING:
ELECTRIC SHOCK HAZARD
DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNDERGROUND AND MAY BE
ENERGIZED
MAIN SERVICE PANEL
NEC 705.12(D)(7) —NEAR PV BREAKER
WARNING:
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT PROTECTION
DEVICE
NEC 705.12(D)(4), 690.56(8) — ON PANEL COVER
WARNING: DUAL POWER SOURCE
POWER IS BEING SUPPLIED TO
THIS PANEL FROM THE UTILITY
AND A SOLAR PV SYSTEM.
THE SOLAR PV DISCONNECT IS
LOCATED:
�u NEC 690.14(C)(2) — NEAR PV BREAKER
NOTE: PV POWER SOURCE CONDUCTORS INSTALLED WITHIN EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING PHOTOVOLTAIC
METHODS, COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES, AND CONDUIT BODIES IN WHICH ANY OF
THE AVAILABLE CONDUIT OPENINGS ARE USED, SHALL BE MARKED WITH THE FOLLOWING WORDING "PHOTOVOLTAIC - AC DISCONNECT
POWER SOURCE" BY MEANS OF PERMANENTLY AFFIXED LABELS SPACED NOT MORE THAN (10) FEET BETWEEN LABELS.
(CEC 690.31(D)(3)). '
NEC 690.54 —.ON PANEL COVER
PRODUCTION METER AC DISCONNECTS
ONLY AT METER LOCATION NEC 690.14(C)(2)
+
PHOTOVOLTAIC PHOTOVOLTAIC
SYSTEM METER AC DISCONNECT
NEC 690.54
'Ir NEC 705.12(D)(4) — ON A LINE SIDE TAP
{t
n WARNING: DUAL POWER SOURCE
SECOND SOURCE IS PV SYSTEM
. ,
DC DISCONNECTS
A) MATERIALS USED FOR MARKING
SHALL WEATHER
vc+•n+rrsr „�,Y
� w •cwl_ rsN�UNCTION+BOX � CONDUITmRACEWAYS
PHOTOVOLTAIC REQUIREMENTS
BE REFLECTIVE,
.
RESISTANT, AND SUITABLE FOR THE
�
PEP, CALIFORNIA ELECTRICALCODEARTICLEfgp .-
ENVIRONMENT, BE OF ALL CAPITALIZED
l s CAUTIpj1j
$Q(pR�jRq�jT
LETTERS WITH A MINIMUM HEIGHT OF
t,n+E��t[tl:(frtl[Tl51kLBElFBEEkTrE'.•Ef•y•
trortn:iataurr m•-ur+ttt, flu�,r[r✓n
3/8 INCH (9.5MM) WHITE ON RED
i
ro,.r;uf•u,.rat�[ia+EcrrEEa..+ ,
BACKGROUND.
f'EIlEYfiATIOtt'sYrl►N1,5'HI"TE
h.rxv. rrlu��w+r
1`rgti ln- rcultlzw3cr
EETTFRRl;Ct+EE[rfE.K
RELT'i'iE L�_ATHETt
B) MARKING SHALL CONTAIN THE
� ,Iy, ^(YA rh,: tlb
Iti Nr Ih .ry�Tri lS%AIRT!
r,ta.lvinerll,.(KaCI
fE514T%.fli E%•0.+if04riN1M1WIEP14
,
SI [T:.RF rCt? t}'E ErfaitragFHT N1TH
'Exlt
WORDS "WARNING: PHOTOVOLTAIC
i,
%FlE aLwC51 F L'C'fd(LYINr l',TTII lK- ��4
POWER SOURCE."
.4-u+,_,n:, -.• •r�•
�.�.�...�� ....,,,,,„�;
V•I•i,i•
ti a4EGEDiFt tl• +,,.. ;_ y.
C CONDUITS SHALL BE SPECIFICALLY,r!
r n•
` a n �r' � �I 1 V 1 A
MARKED EVERY 10 FEET (3048MM),
C; �.t�/
1 1 DEPT.
WITHIN 1 FOOT (305MM), OF TURNS OR
;f$�E�/Qi C -
BENDS AND WITHIN 1 FOT (305MM)
ABOVE AND BELOW PENETRATIONS OF
T,ION
ROOF/CEILING ASSEMBLIES, WALLS OR
FCSR'`CONSTF�'CJC ;
�'
BARRIERS.
NECTS ~
Inw+Nruwallw • * ///
I
°.-,^� / / \\
.
TES-g
w"IF 'X
V-"N:m "�mvmml�
A
It tl ln.lY Oti:x.nryr 1 1+l;MTrl.. Al I
iNFCr
MAR � PANEL
av 1 1�
!_ _ yr• .. I • i•. Nam• ( I .
t
�trai rr.- Nutras•nre.rn/, + -..v. .-,--.•..,.,rM•... / ;i fEPft><1IE67T klcfElC eNatl Ec. �. f I+rnr�th- .al��twk7 z T..,,-/� FF`CNICIOri:•55sti.P(1E -:laFf 11751W7E1 rE +.LLi+1:E1571"[711,f!
Y i+rn++ In •wnvavvr � � P4[H 5EP':!{E f':,f[E[ C•R il'fr%NEL
i. z
#GO
O
Q
W z
Cl.W
ca
w
U
Q w
0
� w
�wLrj
Z Z) N
Q w N
aaa,M
d w a�
J Z U
Ltt a
Z zmz�
Q W Co J
w04
:Lo
2
� N
LaJ
a��vtr2
o
N O= V Q �
tn�U�
I
I- ix M
Q
i
Z N � O
QZW r7 rp
aooMt`
I
o
6/29/15
DRAWN BY: BPM
APN:767-710-03-6
LOT: 1.86 acres
C Erg-r�rz. s
MAIN: MLO
PANEL EMI
LOCATION GARAGE
BUS: 125 AMPS
120/240 VOLTS, 1 PHASE 3 WIRE
MOUNTING INDOOR
LOCATION
LOAD (WATTS) LTS
REC MISC BRKR CRKT
CRKT BRKR LTS
REC MISC LOAD (WATTS)
A B
A B
WINE COMPRESSOF
1277
1
30/2 1
2 '20/1
1 1920 COFFEE
WINE COMPRESSOF
1277
1
* 3
4
WINE FAN
600
1
15/1 5
6
42" REFER
1920
1
20/1 7
8
42" REFER
1920
1
20/1 9
10
11
12.
13
14
15
16
17
18
19
20
21
22
23
- 24
LOAD PHASE A....
5,717
LOAD PHASE B 3,197
TOTAL CONNECTED LOAD........ 8,914
TOTAL NON -CONTINUOUS LOAD
@ 100%
6,360
TOTAL CONTINUOUS LOAD
@ 125%
3,193
TOTAL LOAD ................
9,553
=
39.8 AMPS @ 120/240 VOLTS 1 PHASE, 3 WIRE
3797 3197
1920 0
G
4
J
MAIN: MLO
PANEL EM2
LOCATION GARAGE
BUS: 125 AMPS
120/240 VOLTS, 1 PHASE 3 WIRE
MOUNTING INDOOR
LOCATION
LOAD (WATTS) . LTS
REC MISC BRKR CRKT
CRKT BRKR LTS
REC MISC LOAD (WATTS)
A B
A B
MASTER A/C
3456
1
60/2 1
2
MASTER A/C
3456
1
* 3
4
MASTER FAU
816
20/2 5
6
MASTER FAU
816
* 7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
LOAD PHASE A....
4,272
LOAD PHASE B 4,272
TOTAL CONNECTED LOAD........ 8,544
TOTAL NON -CONTINUOUS LOAD
@ 1000/0
1,632
TOTAL CONTINUOUS LOAD
@ 125%
8,640
TOTAL LOAD ................
10,272
=
42.8 AMPS @ 120/240 VOLTS 1 PHASE, 3 WIRE
4272 4272
0 0
MAIN: MLO
PANEL EM3
LOCATION
GARAGE
BUS: 125 AMPS
120/240 VOLTS, 1 PHASE 3 WIRE
MOUNTING
INDOOR
LOCATION
LOAD (WATTS) LTS
REC MISC
BRKR CRKT
CRKT BRKR LTS
REC MISC LOAD (WATTS)
A B
A B
KITCHEN LIGHTING
400
1
2
1440
PANTRY REFER
MASTER LIGHTING
715
3
4
330
GUEST HALL
MASTER LIGHTING
110
5
6
720
BATH GFI
MASTER LIGHTING
55
7
8
1440
MSTR OUTLETS
MASTER LIGHTING
330
9
10
1920
PROCESSOR
MASTER HALL
165
11
12
UNDER BRIDGE
220
13
14
MASTER BATH
440
15
16
MASTER BATH
550
17
18
MASTER BATH
130
19
20
MASTER BATH
200
21
22
CLOSET LTG
900
23
24
LOAD PHASE A....
5,890
LOAD PHASE B 4,175
TOTAL CONNECTED LOAD........ 10,065
TOTAL NON -CONTINUOUS LOAD
@ 1000/0
10,065
TOTAL CONTINUOUS LOAD
@ 125%
0
TOTAL LOAD ................
10,065
=
41.9 AMPS @ 120/240 VOLTS 1 PHASE, 3 WIRE
1810 2405
4080 1770