BMCH2018-005078-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: ADAM SIMMONS P O BOX 314 LA QUINTA, CA 92247 MECHANICAL/ BMCH2O18-0050 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT 48380 CASITAS DR . . 602112025 BLOMESTEIN / (2) HVAC CHANGEOUTS 14SEER/81 AFUE SPLIT SYSTEM $20,000.00 U MAR 01 2018 Ld CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 780534 Date: Q Contractor: 6`��+ VOICE (760) 777-7125 'FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/1/2018 Owner: RODGER LOMESTEIN 48380 CASITA DR LA QUINTA, CA 92253 Contractor: ADAM SIMMOVS P0BOX 314 LA QUINTA, CA 92247 (760)564-7525 Llc. No.: 780534 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one if the following declarations: I have and will maintain a certificae of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of tl a &ork for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance• carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9054788 I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State _ I certify that in the performance o1 the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner s■ as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair any compensation laws of California, and agree that, if I should become subject to the structure, prior to its issuance, also requires the applicant for the permit to file a signed workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith statement that he or she is licensed pursuant to the provisions of the Contractor's State comply with those provisions. License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business / Z and Professions Code) or that he or she is exempt therefrom and the basis for the Date: $ Applicant: _ G r� > GC alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, (� I, as owner of the property, or my employees with wages as their sole AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO compensation, will do the work, and the structure is not intended or offered for sale. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, apply to an owner of property who builds or improves thereon, and who does the work INTEREST, AND ATTORNEY'S FEES. himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold APPLICANT ACKNOWLEDGEMENT within one year of completion, the owner -builder will have the burden of proving that he IMPORTANT: Application is hereby made to the Building Official for a permit subject to or she did not build or improve for the purpose of sale.). the conditions and restrictions set forth on th*s application. ( )1, as owner of the property, am exclusively contracting with licensed contractors to 1. Each person upon whose behalf this appl cation is made, each person at whose construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State request and for whose benefit work is perforned under or pursuant to any permit issued License Law does not apply to an owner of property who builds or improves thereon, as a result of this application , the owner, andthe applicant, each agrees to, and shall and who contracts for the projects with a contractor(s) licensed pursuant to the defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and Contractors' State License Law.). employees for any act or omission related to Ilhe work being performed under or l—) I am exempt under Sec. B.&P.C. for this reason following issuance of this permit. 2. Any permit issued as a result of this application be null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work Date: Owner: for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for.which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I certify that I have read this application and sate that the above information is correct. I agree to comply with all city and county ordi lances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Dater Signature (ApplicantxAgent): Dater 3%1/2018 . Application Number: BMCH2O18-0050. Owner: Property Address: 48380 CASITAS DR RODGER LOMESTEIN APN: 602112025 48380 CASITA DR Application Description: BLOMESTEIN / (2) HVAC CHANGEOUTS 14SEER/81 AFUE SPLIT SYSTEM LA QUINTA, CA 92253 Property Zoning: Application Valuation: $20,000.00 Applicant: Contractor: ADAM SIMMONS ADAM SIMMONS P0BOX 314 P0BOX 314 LA QUINTA, CA 92247 LA QUINTA, CF. 92247 (760)564-7525 Llc. No.: 780534 -------------------------------------------------------------------------------------------- Detail: (2) HVAC CHANGE OUTS-Y4SEER/81AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPIECTION. 2016 CALIFORNIA BUILDING CODES. . FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM' 101-0000-42402 0 $78.02 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT- SPLIT -SYSTEM PC 101-0000-42600 0 $156.04 Total Paid for CHANGEOUT: $234.06 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE:. $10.00• DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $S.00 $348.89 Bin # City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico. La Quinta, CA 92253 - (760) 777-7012 &vs -o Building Permit Application and Tracking Sheet Permit # GkAci4a41 _ Project Address: 97"3F,() Orl d -e— Owner's Name - Td, 0 ,&Y- , -n A. P. Number: Address: 4 8 3 0 CAS t � P Legal Description: City, ST,.Zip: 1,.0- ®U in 1 yi t_ 019 573 Contractor: C S' Telephon W- t3 Address: Sy y 0 Ave'Irk a �"r n Project Description: City, ST, Zip: (-a Q(J Q Telephon446) S/o State Lic. # : -7 City Lic. #.. Arch., Engr., Designer. Address: City., ST, Zip: Telephone: 3g:"•:V, ::.;r ;:::v«<-;: < .z:>:<>?::><`::>.<.>: ':.<:<•<•.>•-�•o:•<•>x•::>-:;>.;:.:r::>::-::.< Construction Type: Occupancy State Lic. #: , Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: #Units: Telephone #,of Contact Person: -Estimated Value of Project ' 0 O Q. APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES. Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. PIans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subcontactor List Called ContactPcrson Plumbing Grant Decd Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN IiOUSE:- '"' Review, ready for correctionsrissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Feu CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3) Project Name: 48380 CASTITA DRIVE I Date Prepared: 2018-02-20 I A. General Information CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF111-ALT-02 document for each dwelling unit. 01 Project Name 48380 CASTITA DRIVE 02 Date Prepared 2018-02-20 03 Project Location 48380 CASTIA DRIVE 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 48380 CASTITA DRIVE "SC System Dwelling Unit Conditioned CFA served 07 Zip Code 92253 08 Floor Area (ft)2151 Installing Identification or Location or Area by this SC Number of Space containing 09 Climate Zone 15 10 Conditioning (SC) Systems in 2 Served System (ft) system? component? this Dwelling Unit: feet of ducts? I i- -- 1 i f I' -- i�- 1 N--'-) : 1 r 7 t B. Space Conditioning SCS stem Information 01 02 03 \ `' 04 - '-05' _� -06- 07` U 08 -' =09 10 FIs the SCS`' Iiistalli gla > "SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? dud system? SC system? Alteration Type System 1 WHOLE HOUSE 1200 Yes Yes Yes No No No Altered space conditioning system System 2 WHOLE HOUSE 1200 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)iDiib) This section does not apply to this project. Registration Number: 218-A020050879B-000-000-0000000-0000 Registration bate/Time: 2018-02-20 07:03:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-02-20 07:03:51 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CUR -ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3) i 'D. Altered Space Conditioning System (Sections 150.2(b)IE and F) 01 02 03 04 05 06 07 08 09 30 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new Less than or System 1 furnace heating AFUE 81 AC cooling SEER 14 Setback equal to 40 R-8 components components feet Central gas All new Central split All new Less than or System 2 furnace heating AFUE 81 AC cooling SEER 14 Setback equal to 40 R-8 components components feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Dud insulation requirement for the new portions of supply -air and.return-air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Dud Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of dud length is replaced -Leakage rate compliance: <= 15% or <=10% leakage to outside, or seal all accessible leaks. CF211 and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing,requirements. i1 � LJ �,11 Heating -only systems and*Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. Existing dud systems constructed, insulated or sealed with asbestos`are exempt fr0m.IV1CH ZO Duct Leakage Testing requirements ! {{ E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 218-A020050879B-000-000-0000000-0000 Registration Date/Time: 2018-02-20 07:03:13 ,HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-02-20 07:03:51 Schema Version: rev 10/16 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 8 of 8) . Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: �,�� Tom Bachus Company: Signature Date: MLC Building Performance 2018-02-20 07:24:13 Address: CEA/ HERS Certification Identification (if applicable): 77825 Delaware Place City/State/Zip: Phone: Palm Desert CA 92211 760-836-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation Is true and correct. 2. 1 am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b)1 am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. -1 3. The constructed or Installed features, materials, components or manufactured devices (the 1nstallatiori) identified on this Certificate.o` Installation conforms to all.appllcable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance,'plans` and specifications approved by the enforcement agency?) ., '. - j S % % r 1 5 � 4 l 1 i 4. 1 will ensure that a registered copy of this Certificate oflnstallation shall be posted or made available with the building permit(Cs)_,issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered ropy of this Certiific�ajte of Installation is required to be included documentatlon thfj bbuuiilder provides to the building owner at occupancy. }with-ih`el HERS' R S P - r% % i.«/ � � 0.t./ Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Donna Simmons Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): ADAM SIMMONS • OWNER Address: CSLB License: 54440 AVENIDA CARRANZA 780534 CIN/State/Zig; Phone: Date Signed; LA QUINTA CA 92253 760-564-7525 12018-02-20 07:47:50 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 218-AO20050879B-000-001-MO1001A-0000 Registration Date/Time: 2018-02-20 07:47:50 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-02-20 07:17:17 Schema Version: rev 4/7/2017