Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BWFE2017-0234
J °� aw 78-495 CALLE TAMPICO VOICE (760) 777-7125 " FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/29/2017 Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Owner: Application Number: BWFE2017-0234 PRESIDIO FD CITRUS, LLC. Property Address: 50753 CEREZA 73081 FRED WARING DR. APN: 776340022 PALM DESERT,CP.92260 Application Description: CITRUS AT COVE / BLOCK WALL Property Zoning: Application Valuation: $1,000.00 Applicant: ® Contractor: ECOWIZE INC ECOWIZE INC 73081 FRED WARING DRIVE DEC 0 8 2017 73081 FRED WARING DRIVE PALM DESERT, CA 92260 0PALM DESERT, CA 92260 CITY OF LA QUINTA (760)776-8300 DESIGN AND DEVELOPMENT DEPARTMENT Llc. No.: 945713 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 945713 %Date: J —6.70 1 -Contractor: te- 2-tz/' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner.of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec: B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: ! WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of -he following declarations: I have and will maintain a certificate Df consent to self -insure for workers' compensation, as provided for by Section 3700 -if the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' cor-ipensation insurance, as required by Section 3700 of the Labor Code, for the perforrrmnce of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EVEREST NATIONAL INSURANCE COMPANY Policy Number: _ I certify that in the performance of tl-e work for which this permit is issued, I shall not employ any person in any manner so a: to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 12-- R�- 1-2 Applicant: '/moi/? 1✓� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINA_ PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF ' COMPENSATION, DAMAGES AS PROVIDED FOR 14 SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the ISuilding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this applica-ion is made, each person at whose request and for whose benefit work is performec under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Ci -y of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicatbn becomes null and void if work is not commenced within 180 days from date of issjance of such permit, or cessation of work for 180 days will subject permit to cancellaton. I certify that I have read this application and state that the above information, is correct. I agree to comply with all city and county ordinar ces and state laws relating to building construction, and hereby authorize representativ-s of this city to enter upon the above-mentioned property fof inspection purposes. Date: 2 ��' 1 Signature (Applicant or Agent): Applicant: Contractor: ECOWIZE INC ECOWIZE INC 73081 FRED WARING DRIVE . 73081 FRED WARING DRIVE PALM DESERT, CA 92260 PALM DESERT, CAA92260 (760)776-8300 Llc. No.: 945713 Detail: 112 LF OF 6' GARDEN WALL [ANGELUS SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH S-UCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. PER 2016CALIFORNIA BUILDING CODES. Date: 11/29/2017 Application Number: BWFE2017-0234 Owner: Property Address: 50753 CEREZA PRESIDIO FD CITRJS, LLC. APN: 716340022 73081 FRED WARING DR. Application Description: CITRUS AT COVE / BLOCK WALL PALM DESERT, CA 92260 Property Zoning: Application Valuation: $1,000.00 Applicant: Contractor: ECOWIZE INC ECOWIZE INC 73081 FRED WARING DRIVE . 73081 FRED WARING DRIVE PALM DESERT, CA 92260 PALM DESERT, CAA92260 (760)776-8300 Llc. No.: 945713 Detail: 112 LF OF 6' GARDEN WALL [ANGELUS SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH S-UCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. PER 2016CALIFORNIA BUILDING CODES. Total Paid for TECHNOLOGY ENHANCEMENT FEE: , $5.00 DESCRIPTION FINANCIAL INFORMATION ACCOUNT aTY AMOUNT WALL/FENCE - EA ADDITIONAL 50 LF 101-0000-42404 0 $15.60 DESCRIPTION ACCOUNT aTY AMOUNT WALL/FENCE - FIRST 100 LF' 101-0000-42404 0 .$52.01 DESCRIPTION ACCOUNT MATY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $65.02 Total Paid for BLOCK WALL: $132.63 DESCRIPTION ACCOUNT 11TY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: , $5.00 )V13L ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN • CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC '2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. 'REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 'INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD–DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION; SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE–AND-GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. S. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS. OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E–Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. )FIRST COURSE MAY BE WET–SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK .SHALL BE LAID IN RUNNIN( VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACE[ 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE MORTAR. WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY F FOOTING REINFORCING IS TIED IN PLACE. B. l REINFORCEMENT IS IN PLACE ANO'CELLS ARE 12. FOR TYPICAL FOOTING STEP AND DRAINAGE E SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A MASONRY FENCE WALL SCHEDULE 'H' MAX.'X' BARS 'B' MIN. 16"LONG CMU 18" LONG CMU 6'-0" #4®48"o.c. 4@54"o.'c. 1'-11" 6'-8" 4®40"o.c. 4045"o.c. 2'-1" 7'-4" #4@32"ox. 4®36"o. c. 2'-3- 8'-0" 4@24"o.c. 4027"o.c. 2'-6" 6' to 8' High Site Wall Concentric Spread Footing C @ 110mph (ult.) Risk Category I 6" Wide CMU OPTIONAL WALL CAP 6 STD. LADDER TYPE #5 STD FOR SLUMPSTONE)_ JOINT REINF. AT TOP COURSE, AT FIRST COURSE, AND 24"o.c. 6" WIDE' (NOM.) CMU GROUT CELLS w/ REINF. J a 'X' BARS PER U SCHEDULE ® ? 1n CTR. OF WALL w IL DWLS. TO MATCH VERT. REINF. LAP 24" MIN. BOND PATTERN WITH EQ. EQ. F.G. AT A MAXIMUM OF STUCCO COATED OR WET–SET FIRST COURSE 2–#4 CONT. )R CONCRETE AND ALL — FTER VERTICAL READY FOR GROUT. LOCK–OUT DETAILS CONT. CON[. FTG. ;LOPE ALT. BENDS B' MIN. PER SCHEDULE GHL INC. n:•:::FiITEC:: ENrI:V[:F:llN(:i �.� 228 East Baclillo Street 1 Covina, CA 91723 g r T: 626.938.1595 =5. r: 626.938.0485 I" v,unv.ghl-Oe.Corn {i & CITY OF � QUINTA BUI/L�DIINGG & SAFETY DEPT iA 9 RO ED FOR CONSTRUCTION . DATE jk BY_ cli 3" CLR. TYP. DATE SIGNED 4-12-17 S-1.OLQ Bin #i Cl ty ofLa C� CIiI� ta . . Building 8F Safety Division Permit n 78-495 Calle Tampico La Quinta, CA 92253- (760) 777-701,2 Building Permit Application and Tracking Sheet Project Address:� Owner's Name:�r" . �t$ !'bl'/ U /J CII 2U:Y-LC c • A. P. Number. 4,e Address: ,305"l BRED (/�r11F1(!(r Legal Description: City, ST, Zip: 10A,1111 oesc/ -, q 220 ---....---------- — - --- ----- - Contractor: CCJ 1 2 C -(C - - - —. Telephone: Address: ©.S? Project Description: City, ST, Zip: %A-zM CA- Tellephone: Po . h ......... P� r l G (i' f�' L v G C %� - C d C C) Staie Lic. # : _' City Lic- #; , Arch., Engr., Designer: ' Address: City., ST, Zip: Telephone: . Occupancy: Construction Type: . cY: F ,- State#.• Lic. ProJect type circle one), New Add'n Alter Repair - Demo' Name of Contact Person: Sq. Ft-: #Stories: #Units: Telephone # of Contact Person: Estimated Value -of Project: APPLICANT:'DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'dTRACKING.. PERMIT FEES" ' Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plin Check Dep -)sit Truss'Calcs. Called Contact Pcrson Plan Check Balance. Tift 24 Calcs. .. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical . Grading plan .2°" Review, ready for correctionslssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up SM -1. II.O.A. Approval • Plans resubmitted Grading IN ROUSE:- Rcpiew, ready for corrcctionsrssuc Developer Impa=t Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, 1 Total Permit Fe -s