Loading...
BMCH2017-035478-495 CALLE TAMPICO c&!t 4 4v Q91k& LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0354 Property Address: 77535 CALLE CHIHUAHUA APN: 774051024 Application Description: WOOSTER / HVAC CHANGEOUT - 14SEER/81AFUE RACKAGED UNIT Property Zoning: Application Valuation: $9,000.00 Applicant: BURGESONS HEATING AND AIR CONDITIONING I P 0 BOX 7310 REDLANDS, CA 92375-0310 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: 26382-1— Thereby affirm under penalty of perjury that I am exempt from the Cont ctor' tate License Law for the following reason (Sec. 7031.5, Business and Profession ode: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended. or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:_ Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 . Date: 8/10/2017 t/ Owner: ANDREW WOOSTER 77535 CALLE CHIHUAHUA LA QUINTA, CA 92253 Contractor: BURGESONS -iEATING AND AIR CONDITIONING I P0BOX 7310 REDLANDS, CA 92375-0310 (909)793-3685 Llc. No.: 263E71 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certifi:ate of consent to self -insure for workers' compensation, as provided for by Section 2700 of the Labor Code, for the performance M3� k for which this permit is issued. I have and will maintain workers compensation insurance, as required by 00 of the Labor Code, for the peformance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: ACE AMERICAN INSURANCE OMFANY Policy Number - I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. D App' n . WARNING: FAILURE TO SECURE WOR ERS'tOMPENS TIO COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENQ(�IES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED POR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cty of La Quinta, its officers; agents, and !employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this apolication becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work . for 180 days will subject permit to cancella:ion. I certify that I have read this application an -3 state that the above information is correct. I agree to comply with all city and county o-dinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purpose. or a Date: 8/10/2017 Application Number: BMCH2O17-0354 Owner: Property Address: 77535 CALLE CHIHUAHUA ANDREW WCOSTER APN: 774051024 77535 CALLE CHIHUAHUA Application Description: WOOSTER / HVAC CHANGEOUT - 14SEER/81AFUE PACKAGED. UNIT LA QUINTA, CA 92253 Property Zoning: Application Valuation: $9,000.00 Applicant: Contractor: 'BURGESONS HEATING AND AIR CONDITIONING I BURGESONS -lEATING AND AIR CONDITIONING I P 0 BOX 7310 P 0 BOX 7310 REDLANDS, CA 92375-0310 REDLANDS, CA 92375-0310 (909)793-3685 -------.------------------------------------------------------------------------------------- LIc. No.: 263E-11 Detail: HVAC CHANGE OUT - 14SEER/81AFUE PACKAGED SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. a DESCRIPTION ACCOUNT QTY AMOUNT BSAS 561473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - PACKAGED UNIT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - PACKAGED UNIT PC 101-0000-42600 0 $25.33 Total Paid for CHANGEOUT: $63.33 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 .DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE .502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 .0 u t Bin# -0q,5H City of La Quinta Building & Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 BuildingPermit Application and Tracking Sheet Permit# JFr0Q-lo101 Project Address: 2 J Owner' Name: A.P. Number Address: Legal Description: City, ST, Zip: Contractor:Telephone: : _ Address Z, Project Description: City, ST, Zip: _/ 2 Telephone: .3 State Lic. #:19 9-7 Ci Lic #: Arch, Engr., Designer: AV 19441 - Address: 14 City, ST, Zip: ' Telephone:,?Construction Type: Occupancy: State Lic. ' d Proj. Type New Add'n Alter Repair Demo Name of Contact: h SgFt: #Stories # Units: Telephone of Contact: / / Estim dlue oProject: APPLICANT: DO NOT WRIMBELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERM_T FEES Plan Sets Plan Check Submitted Item Amount+ Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan Check Balance: Title 24 Calcs Plans Picked Up Constriction: Flood Plain Plan Plans Resubmitted Mechanical: Grading Plan 2nd Rev; Ready for corrections / Electrical: Subcontractor List Called Contact Person Plumbing: Grant Deed Plans Picked Up. S.M.I. HOA Approval Plans Resubmitted Gradin, IN-HOUSE 3rd Rev, Ready for corrections / Develooer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Apps Date of permit issue School Fees Total P-rmit Fees 0 4 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) Project Name: ANDREW WOOSTER I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2017-08-09 A. General Information CF111-ALT-02 is applicable t4 multiole space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name ANDREW WOOSTER 02 Date Prepared 2017-08-09 03 Project Location 77535 CALLE CHIHUAHUA 04 Building Type Single family 05 CA City La Quinta06 Dwelling Unit Name HOUSE SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Dwelling Unit Conditioned Location or Area 07 Zip Code 92253 0811 Floor Area (ft2) 2500 entirely new Name Served System (ft) system? component? components? y „w c duct system? Number of Space I Alteration Type 09 Climate Zone 15 "" Yes Conditioning (SC) Systems in 1 No No r X10 this Dwelling Unit: B. Space Conditioning (SC) System Information �„ 01 02 03 04 "40 d 05 * '. 064, 07 08 09 10 Is the SC Onry Installing,a, ats.:r "� "� ;M i ., -,a iA.#h lnteor i�• SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? I Alteration Type SYSTEM HOUSE 2500 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section iS0.2(b)iDiib) This section does not apply to this project. Registration Number: 417-A020108627A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-08-09 13:20:02 Report Version: 2016.1.006 Schema Version: rev 10/16 HERS Provider: CHEERS Report Generated: 2017-08-09 13:20:02 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new Less than or SYSTEM heating AFUE 0.81 AC cooling SEER 14 Setback equal to 40 R-8 furnace components components feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6.(CZ 1: 1Q 12 erid 13) and R8 (CZ 11 and 14-16) CF2R and CF311-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed. in_dueted-systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 1091. leakage to outside, or seal all accessible leaks.�� CF2R and CF311-MCH-25-H Refrigerant Charge verification required when refrigerant containing components -are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage'Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. fo- V__J0 it— . 4t___ IN 7l, W_` �:'+ tt .ft - ►`�"� kik E. Entirely New or Complete Replacement Duct System, with or without Equipml'ent Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F) This sect on d es not applyltotli s prroject. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 417-A020108627A-000-000-0000000-0000 Registration Date/Time: 2017-08-09 13:20:02 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-09 13:20:02 Schema Version: rev 10/16 7 IZ � CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Kevin Burgeson Kev%n.8us^rjebon. Company: Signature Date: Burgesons Heating & Air Conditioning 2017-08-09 Address: CEA/ HERS Certification Identification (if applicable): 620 Tennessee Street City/State/Zip: I Phone: 909-792-2222 Redlands CA 92374 ,..-� Responsible Person's Declaration statement I certifythe following under penalty of perjury, 4 g p y p � ry, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. � � 2. lam eligible under Division 3 of the Business and Professions Code to accept responsibility, for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for,approval;with this building permit application. .kyr dt✓ �4' d:l _..,, k� � it �✓< �=.. 5. 1 will ensure that a registered copy of this Certificate of Compliance'shall be made available with the building=permit(s) issued for the building, and made available to the enforcement agency for all applicable ti_" inspections. I understand that a registered copy of this Certificate of Compliance isfrequired to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name:Responsible, Unmatcheed Sar 4f. Designer Signature: Kevin Burgeson Company: Date Signed: Burgesons Heating & Air Conditioning 2017-08-09 Address: License: 620 Tennessee Street 263871 City/State/Zip: Phone: Redlands CA 92374 909-792-2222 Digitally signed by CHEERST`^. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 417-A020108627A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-08-09 13:20:02 Report Version: 2016.1.006 Schema Version: rev 10/16 HERS Provider: CHEERS Report Generated: 2017-08-09 13:20:02