Loading...
BCOM2017-00284 O78 -4S15 CALLE TAMPICO w LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT Applicant: AGOURA HILLS INVESTMENT GROUP INC DBA TH 43036 MADISON ST STE B INDI0, CA 92201 A AUG 18 2017 CITYOFLAQUINTA — COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of,perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 740276 Iffb5te /7 Contractor.!/�?/( OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold ' within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the'property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). . (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/18/2017 Owner: JAMES PAUL 55585 CHERFY HILLS LA QUINTA, CA 92253 Contractor: AGOURA HILLS INVESTMENT GROUP INC DBA TH 43036 MADI50N ST STE B INDIO, CA 92201 (760)772-3585 Llc. No.: 740276 - WORKER'S COMPEKSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certifi--ate of consent to self -insure for workers' compensation, as provided for by Section _700.of the Labor Code, for the performance of k 111 -have which this permit is issued. . have and will maintain workers compensation insurance, as required by th Section 3700 of the Labor Code, for the pefformance of the work for which this permit is . issued. My workers' compensation insurance carrier and.policy number are: Carrier: SECURITY NATIONAL INSURANCE COMPANY Policy Number: SWC1135278 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' . compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those -provisions. WARNING: FAILURE TO SECURE WORKERS'lCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($10C,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED =OR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, ad the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of L.suance of such permit, or cessation of work for 180 days will subject permit to cancella-ion. I certify that I have read this application and state that the above information1s correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Lender's Address: ( Date,.)/ I U 1 ?Iannfi11fP IGI1rillrnntnr-Aaonti• BUILDING PERMIT Application Number: BCOM2017-0028 Property Address: 79440 CORPORATE CENTRE DR STE 119 APN: 600390022 Application Description: PAUL / 3,053SF MEDICAL OFFICE TI/VB/B-OCC/31-OL/SPRINKLED Property Zoning: Application Valuation: $350,000.00 Applicant: AGOURA HILLS INVESTMENT GROUP INC DBA TH 43036 MADISON ST STE B INDI0, CA 92201 A AUG 18 2017 CITYOFLAQUINTA — COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of,perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 740276 Iffb5te /7 Contractor.!/�?/( OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec, 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold ' within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the'property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). . (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/18/2017 Owner: JAMES PAUL 55585 CHERFY HILLS LA QUINTA, CA 92253 Contractor: AGOURA HILLS INVESTMENT GROUP INC DBA TH 43036 MADI50N ST STE B INDIO, CA 92201 (760)772-3585 Llc. No.: 740276 - WORKER'S COMPEKSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certifi--ate of consent to self -insure for workers' compensation, as provided for by Section _700.of the Labor Code, for the performance of k 111 -have which this permit is issued. . have and will maintain workers compensation insurance, as required by th Section 3700 of the Labor Code, for the pefformance of the work for which this permit is . issued. My workers' compensation insurance carrier and.policy number are: Carrier: SECURITY NATIONAL INSURANCE COMPANY Policy Number: SWC1135278 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' . compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those -provisions. WARNING: FAILURE TO SECURE WORKERS'lCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($10C,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED =OR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, ad the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of L.suance of such permit, or cessation of work for 180 days will subject permit to cancella-ion. I certify that I have read this application and state that the above information1s correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. Lender's Address: ( Date,.)/ I U 1 ?Iannfi11fP IGI1rillrnntnr-Aaonti• ' Date: 8/18/2017 i Application Number: BCOM2017-0028 Owner: Property Address: 79440 CORPORATE CENTRE DR STE 119 JAMES PAUL APN: 600390022 55585 CHERRY HILLS I Application Description: PAUL/ 3,053SF MEDICAL OFFICE TI/VB/B-OCC/31-OL/SPRINKLED LA QUINTA, CA 92253 Property Zoning: ` Application Valuation: $350,000.00 . I I� Applicant: • i 'Contractor: AGOURA HILLS INVESTMENT GROUP INC DBA TH AGOURA HILLS INVESTMENT GROUP INC DBA TH 43036 MADISON ST STE B 43036 MADISON ST STE B INDIO, CA 92201 INDIO, CA 92201 (760)772-3585 --------------------------------------------------------- Llc. No.: 740276. ----- Detail: 3,053SF MEDICAL OFFICE TI/VB/B-OCC/31-OL/SPRINKLED (DESERT VEIN AND VASCULAR ------------------------------ INSTITUTE] EXTERIOR ACCESSIBILITY PATH OF TRAVEL . IMPROVEMENTS REQUIRED TO BE COMPLETED PRIOR TO FINAL INSPECTION. THIS PERMIT DOES NOT INCLUDE SHELL BUILDING IMPROVEMENTS.OR BUILDING SIGNAGE. TUMF AND DIF NOT APPLICABLE, NO CHANGE OF USE OR ADDITIONAL IMPACT. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION I ACCOUNT QTY AMOUNT ART IN PUBLIC PLACES - COMMERCIAL REMOD 270-0000-43201 0 $1,250.00 Total Paid for ART IN PUBLIC PLACES - AIPP: $1,250.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $14.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $14.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA ADDITION 2,000SF 101-0000-42403 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, EA. ADDITION 2,000SF, PC 101-0000-42600 0 $10.13 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,600SF 101-0000-42403 0 $114.00 DESCRIPTION ACCOUNT QTY AMOUNT NON-RESIDENTIAL, FIRST 2,000SF, PC 101-0000-42600 0 $88.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $250.29 DESCRIPTION ACCOUNT QTY AMOUNT FIRE COMMERCIAL TI 101-0000-22811 1 $614.00 Total Paid for FIRE COMMERCIAL TI: $614.00 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $20.28 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $5.07 Total Paid for MEChtANICAL: $88.70 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $228.06 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $228.06 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $501.73 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $136.80 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $109.44 DESCRIPTION ACCOUNT QTY , AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $439.28 DESCRIPTION ACCOUNT QTY1 AMOUNT SMI - COMMERCIAL 101-0000-20308 0 $98.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $98.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 ..$5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS:0• Bin # City of La Quinta Building 8f Safety Division 78-495 Calle Tampico " cogs. La Quinta, CA 92253.- (760) 777-7012 Building Permit Application and Tracking Sheet Permit ProjectAddress: © O2 �- (,'I` A Owner's Name: A. P. Number: p . 3 5'�' dZZ Z % ( Address: ,S!S -g 5-. & R y1�/s A'L Legal Description: City, ST, Zip: 40w% A— Contractor: 2 aN Tele h Pne: 0 ..........................................:. Address: 43(33(- MA (Sade Sr. Project Description: City, ST, Zip: /Al j>/U T - Tele hone: 6d -72 3S - O � G CtJ L /[ r State Lic. # : 74f'0 2 %,& City Lic. #: Arch., Engr., Designer, IA W R 6 -pa Address: �' /Sit/ 'A [�! O City, ST, Zip: % f Z Lc? Telephone: �o�3n f 9Z�f3 . State Lic. #: Name of Contact Person: 2 ^ANS ' Constructiontru coon Ty Pe:�ikA N Occu an c : T % Y Project type (circle one): New Ad3'n AlterRepair Demo Sq. Ft.: S 3 #Stories: �l� #Units: Telephone # of Contact Person: fly.- as b Estimated Value of Project: , C)QQ APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calm Reviewed, ready for corrections Plan Che --k Deposit Truss Calcs. Called Contact Person Plan Che --k Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrcctionsrissue Electrical' Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A.- Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees IR, t: k., t: [V t: U Total Permit Fees AUG. 0 3'2017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Bin # 0v of La Quinta 4 Building &r Safety Division Permit #+'�" 78 495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: f� ("02 -T:i ( ,q A. P. Number: �Q 3 5'0 - dZZ — Z 4 1(• 1 Legal Description: Owner'sName: Address: � 5'g S- � Q City, ST, Zip: . 74 CA - Contractor: l , Telephone: Address: � 6 3 4 if A (s6 dJ City, ST, Zip: lAjp/o [A Telephone: P b -� - % 7 6 Z 3s8s State Lic. # s7r, j� <s Project Description: Arch., Engr., Designer: 1A L3 R C � T Address: T I S4L r,F� e}t.J �• ��V City, ST, Zip: j f CA Telephone: - Q� �3 C7 Stale Lic. #: Z Z" •'Y=;_;:-,+..•;_:=>:=>:=>:=: •: '' � Construction Type:T&/ANl /Q/POccupancy: j Project e circle one): New Add'n Alter Repair Dem o Name of Contact Person: 411 1k, ���,,� ' Sq. Ft_: S 3 # Stories: p6,� # Units: Telephone # of Contact Person: �%� - �%Z Estimated Value of Project: .boo APPLICANT: DO NOT WRITE BELOW THIS LINE # I Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correctionsrssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A: Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees ¢ � � w Total Permit Fees BUILDING ENERGY ANALYSIS REPORT PROJECT: Desert Vein & Vascular Institute TI 79440 Corporate Center Way, Suite 119 La Quinta, CA 92253 Project Designer: Lawrence C. Reeves, L.P. 49-850 Jefferson St., Suite 130 Indio, CA 92201 (818) 425-0830 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 CITY OFLA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION SUMA7461. oo?.S Job Number: Date: 7/25/2017 RE VE. 4 a i.1INTA (00 P,twit.* . � DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form PRF-01-E Certificate of Compliance 3 Form ENV-MM Envelope Mandatory Measures 22 Form ELC-01-E Electrical Power Distribution 23 HVAC System Heating and Cooling Loads Summary 29 Zone Load Summary 30 rn� EnergyPro 7.1 by EnergySoft Job Number: ID: User Number: 6712 Project Name: Tenant Improvement NRCC-PRF-01-E Page 1 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x A. PROJECT GENERAL INFORMATION 1. Project Location (city) La Quinta S. Standards Version Compliance2016 2. CA Zip Code 92253 9. Compliance Software (version) EnergyPro 7.1 3. Climate Zone 15 10. Weather File PALM-SPRINGS-INTL_722868_CZ2010.epw 4. Total Conditioned Floor Area in Scope 3,221 ftZ 11. Building Orientation (deg) (S) 180 deg S. Total Unconditioned Floor Area 0 ftZ 12. Permitted Scope of Work ExistingAlteration 6. Total # of Stories (Habitable Above Grade) 1 13 Building Type(s) Nonresidential 7. Total # of dwelling units 0 14 Gas Type NaturalGas B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft Z-yr) § 140.1 BUILDING COMPLIES 1. Energy Component 2. Standard Design (TDV) 3. Proposed Design (TDV) 4. Compliance Margin (TDV) S. Percent Better than Standard Space Heating 0.32 0.35 -0.03 -9.4% Space Cooling 213.04 202.91 10.13 4.8% Indoor Fans 160.80 159.38 1.42 0.9% Heat Rejection -- - -- Pumps & Misc. - -- Domestic Hot Water 5.11 15.49 -10.38 -203.1% Indoor Lighting 78.27 41.49 36.78 47.0% COMPLIANCE TOTAL 457.54 419.62 37.92 8.3% Receptacle 110.83 110.83 0.0 0.0% Process -- -- Other Ltg -- "- TOTAL 568.37 530.45 37.9 6.7% CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 2 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time. 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings) 1st Indoor Lighting: Check lighting Compliance Margin By Energy Camponenr (from Table Indoor Lighting Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Space Heating Domestic: Hot Water v-- Penalty B column 4) = Energy Credit 2nd Space Cooling: Check envelope and mechanical 3rd Indoor Fans: Check envelope and mechanical 4th Heat Rejection: Check envelope and mechanical 5th Pumps & Misc.: Check mechanical 6th Space Heating: Check envelope and mechanical 7th Domestic Hot Water: Check mechanical D. EXCEPTIONAL CONDITIONS This project includes Domestic Hot Water in the analysis. Please verify that Domestic Hot Water is included in the design for the permitted scope of work. E. HERS VERIFICATION This Section Does Not Apply F. ADDITIONAL REMARKS None Provided CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 3 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY identify which building components use the performance or prescriptive path for compliance. ' NA"= not in project For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans. Building Component Compliance Path Compliance Forms (required forsubmittal) Location of Mandatory Notes on Plans Envelope ❑ Performance NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E ® NA Mechanical ® Performance NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E ❑ NA Domestic Hot Water ® Performance NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PLB-01-E ❑ NA Lighting (Indoor Conditioned) ® Performance NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ NA Covered Process: Commercial Kitchens ❑ Performance S2 (section of the NRCC-PRF-01-E) ElPrescriptive NRCC-PRC-01/ 03 E ® NA Covered Process: Computer Rooms ❑ Performance 53 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC PRC-01/ 04-E ® NA Covered Process: Laboratory Exhaust ❑ Performance S4 (section of the NRCC-PRF-01-E) ❑ Prescriptive NRCC-PRC-01/ 09-E ® NA CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 4 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY The following building components are only eligible for prescriptive compliance. Indicate which are The following building components may have mandatory requirements per Part 6. Indicate relevant to the project. which are relevant to the project. Yes NA Prescriptive Requirement Compliance Forms Yes NA Mandatory Requirement Compliance Forms Lighting (Indoor Commissioning: §120.8 ❑ ® Unconditioned) §140.6 NRCC-LTI-01 / 02 / 03 / 04 / 05-E ❑ ® Simple Systems NRCC-CXR-01 / 02 / 03 / 05-E ❑ ❑ Complex Systems NRCC-CXR-01 / 02 / 04 / 05-E ❑ ® Lighting (Outdoor) §140.7 NRCC-LTO-01 / 02 / 03-E ® ❑ Electrical: §130.5 NRCC-ELC-01-E ❑ ® Lighting (Sign) §140.8 N RCC- LTS-0 1- E ❑ ® Solar Ready: §110.10 NRCC-SRA-01 / 02-E Covered Process: §120.6 NRCC-PRC-01-E ❑ ® Parking Garage NRCC-PRC-02-E ❑ ® Solar Thermal Water NRCC STH Ol E El® Commercial Refrigeration NRCC-PRC-05-E Heating: §140.5 ❑ ® Warehouse Refrigeration NRCC-PRC-06/07/08-E ❑ ® Compressed Air NRCC-PRC-10-E ❑ ® Process Boilers NRCC-PRC-11-E CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 5 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Envelope ❑ NRCI-ENV-01-E - For all buildings ❑ ❑ ❑ NRCA-ENV-02-F- NFRC label verification for fenestration ❑ ❑ Mechanical ® NRCI-MCH-01-E - For all buildings with Mechanical Systems ❑ ❑ ❑ N RCA-M CH-02-A- Outdoor Air ❑ ❑ ❑ NRCA-MCH-03-A—Constant Volume Single Zone HVAC ❑ ❑ ❑ NRCA-MCH-04-H- Air Distribution Duct Leakage ❑ ❑ ❑ NRCA-MCH-05-A- Air Economizer Controls ❑ ❑ ❑ NRCA-MCH-06-A- Demand Control Ventilation ❑ ❑ ❑ NRCA-MCH-07-A—Supply Fan Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-08-A- Valve Leakage Test ❑ ❑ ❑ NRCA-MCH-09-A—Supply Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls ❑ ❑ ❑ NRCA-MCH-11-A—Auto Demand Shed Controls ❑ ❑ ❑ NRCA-MCH-12-A- Packaged Direct Expansion Units ❑ ❑ ❑ NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units ❑ ❑ ❑ NRCA-MCH-14-A- Distributed Energy Storage ❑ ❑ ❑ NRCA-MCH-15-A—Thermal Energy Storage ❑ ❑ ❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-17-A—Condensate Water Temp Reset Controls ❑ ❑ ❑ NRCA-MCH-18-A- Energy Management Controls Systems ❑ ❑ ❑ NRCV-MCH-04-H- Duct Leakage Test ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 6 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name Desert Vein TI-La Quinta-TCZ-17.cibdl6x H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Plumbing ® NRCI-PLB-01-E - For all buildings with Plumbing Systems ❑ ❑ ❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ElNRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application. ❑ ❑ ❑ NRCI-STH-01-E - Any solar water heating ❑ ❑ Indoor Lighting ® NRCI-LTI-01-E - For all buildings ❑ ❑ ❑ NRCI-LTI-02-E -Lighting control system, or for an Energy Management Control System (EMCS) ❑ ❑ ❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter,, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting ❑ ❑ ❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater ❑ ❑ ❑ NRCI-LTI-05-E -Lighting Control Credit Power Adjustment Factor (PAF) ❑ ❑ ❑ NRCI-LTI-06-E - Additional wattage installed in a video conferencing studio ❑ ❑ ❑ NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls. ❑ ❑ ❑ NRCA-LTI-03-A - Automatic daylighting controls ❑ ❑ ❑ NRCA-LTI-04-A - Demand responsive lighting controls ❑ ❑ Outdoor Lighting ❑ NRCI-LTO-01-E — Outdoor Lighting ❑ ❑ ❑ NRCI-LTO-02-E- EMCS Lighting Control System ❑ ❑ ❑ NRCA-LTO-02-A - Outdoor Lighting Control ❑ ❑ Sign Lighting ❑ NRCI-LTS-01-E —Sign Lighting ❑ ❑ Electrical ® NRCI-ELC-01-E - Electrical Power Distribution ❑ ❑ Photovoltaic ❑ NRCI-SPV-01-E Photovoltaic Systems ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 7 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) — Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment. Confirmed Building Component Compliance Forms (required for submittal) Pass Fail Covered Process ❑ NRCI-PRC-01-E Refrigerated Warehouse ❑ ❑ ❑ NRCA-PRC-01-F- Compressed Air Systems ❑ ❑ ❑ NRCA-PRC-02-F- Kitchen Exhaust ❑ ❑ ❑ NRCA-PRC-03-F- Garage Exhaust ❑ ❑ ❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls ❑ ❑ ❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls ❑ ❑ ❑ NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls ❑ ❑ ❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor ❑ ❑ ❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System ❑ I ❑ I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information) 1. Total Conditioned Floor Area 3,221 ft2 5. Number of Floors Above Grade 1 Confirmed 2. Total Unconditioned Floor Area 0 ft2 6. Number of Floors Below Grade 0 3. Addition Conditioned Floor Area 0 ft2 � T 4. Addition Unconditioned Floor Area 0 ft2 V 7. Opaque Surfaces & Orientation 8. Total Gross Surface Area 9. Total Fenestration Area 10. Window to Wall Ratio North Wall 468 ft2 75 ft2 16.0% ❑ ❑ East Wall 738 ft2 0 ft2 00.0% ❑ ❑ South Wall 468 ft2 105 ft2 22.4% ❑ ❑ West Wall 738 ft2 165 ft2 22.4% ❑ ❑ Total 2,412 ft2 345 ft2 14.3% ❑ ❑ Roof 3,220 ft2 0 ft2 00.0% ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 8 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x J. FENESTRATION ASSEMBLY SUMMARY § 110.6 Confirmed 1. 2. 3. 4. S. 6. 7. 8. 9. Fenestration Assembly Name / Fenestration Type / Product Type Overall Overall Overall '; Tag or I.D. Frame Type Certification Method' Assembly Method Area ftZ U-factor SHGC VT N VerticalFenestration Existing Window FixedWindow Default Performance Manufactured 345 0.71 0.73 0.77 E ❑ ❑ MetalFraming ' Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.6-A and fable 110.6-a. Center of Glass (COG) values are for the glass -only, determined by the manufacturer, and are shown for ease of verification. Site -built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis. Z Status: N - New, A -Altered, E- Existing Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information) No K. OPAQUE SURFACE ASSEMBLY SUMMARY § 120.7/ § 140.3 Confirmed 1. 2. .3. 4. S. 6. 7. 8. Surface Name Surface Type Z Area(ft) Framing Type Cavity R-Value Continuous R-Value U-Factor / F-Factor / C-Factor d C R-30 Roof9 Roof 3220 NA 0 30 U-Factor:0.030 E ❑ ❑ R-19 Wall (W.19.2x6.16)11 ExteriorWall 1674 Wood 19 NA U-Factor: 0.072 E ❑ ❑ R-11 Wall Partition18 ExteriorWall 738 Wood 11 NA U-Factor: 0.110 E ❑ ❑ Slab On Grade28 UndergroundFloor 3,120 NA 0 NA F-Factor: 0.730 E ❑ ❑ Z Status: N - New, A -Altered, E- Existing L. ROOFING PRODUCT SUMMARY I § 140.3 Confirmed 1. 2. 3. 4. 5. 6. 7. Product Density Aged Solar Thermal Cool Roof Roofing Product Product Type (lb/ftZ) Reflectance Emittance SRI Credit Description R-30 Roof9 5.32333 0.08 0.75 NA No NA ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 11 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)' § 140.6 Confirmed 1. 2. 3. 4. S. i 4 Occupancy Type Conditioned Floor Area 2 Installed Lighting Power Lighting Control Credits Additional (Custom) Allowance (ftZ) (Watts) (Watts) Area Category Footnotes Tailored Method (Watts) ❑ ❑ (Watts) Medical and Clinical Care 3,221 2,049 0 0 0 ❑ ❑ Building Totals: 3,221 2,049 0 0 0 1 See Table 140.6•C Z See NRCC-LTI-01-E for unconditioned spares 3Lighting information for existing spaces modeled is not included in the table 4Multiple entries for an Occupancy Type may be listed in the table as these have been aggregated for Building Stories that have the same floor multiplier. R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)l § 130.0 Luminaire Schedule (includes all permanent installed lighting in conditioned space, and portable lighting over 0.3 w/ftZ in offices) Installed Watts (Conditioned) Confirmed Name or Item Tag3-lam Complete Luminaire Description (i.e., p fluorescent troffer, F32T8 one dimmable electronic ballast) Watts per luminaire P How Wattage is Determined Total Number Luminaires Installed Watts Pass Fail CEC Default from NAB According to §130.0(c) A A-13.2 W Can 13 Yes No 85 1,121 ❑ ❑ C (3) 4 ft Fluorescent T8 79 Yes No 6 474 ❑ ❑ E E-Cove-3 W/F 3 Yes No 151 453 ❑ ❑ '"lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminaire Schedule details. SS. COVERED PROCESS SUMMARY — ENCLOSED PARKING GARAGES § 140.9 This Section Does Not Apply S2. COVERED PROCESS SUMMARY —COMMERCIAL KITCHENS § 140.9 This Section Does Not Apply CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 12 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x S3. COVERED PROCESS SUMMARY - COMPUTER ROOMS § 140.9 This Section Does Not Apply 54. COVERED PROCESS SUMMARY - LABORATORY EXHAUSTS § 140.9 This Section Does Not Apply T. UNMET LOAD HOURS This Section Does Not Apply U. ENERGY USE SUMMARY Energy Component Standard Design Site (MWh) Proposed Design Site (MWh) Margin (MWh) Standard Design Site (MBtu) Proposed Design Site (MBtu) Margin (MBtu) Space Heating 0.1 0.1 0.0 Space Cooling 24.0 22.7 1.3 Indoor Fans 24.1 23.8 0.3 Heat Rejection - •- -- Pumps & Misc. - -- - Domestic Hot Water - 2.2 -- 11.4 Indoor Lighting 10.8 5.7 5.1 -- COMPLIANCE TOTAL 59.0 54.5 4.5 21.4 0.0 -- Receptacle 14.7 14.7 0.0 10.0 10.0 0.0 Process -• -- -- -- -- -- Other Ltg -• -- - -- - -- TOTAL 73.7 69.2 4.5 21.4 10.0 11.4 CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 13 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlte ration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT § 10-103 I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Signature: Company: Scott Design and Title 24, Inc, Address: 74-818 Velie Way, Suite #8 Signature Date: City/State/Zip: Palm Desert CA 92260 CEA Identification (If applicable): Phone: (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am 1 licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its 2 preparation; and that I am a licensed contractor performing this work. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to 3 Business and Professions Code Sections 5537, 5538 and 6737.1. Responsible Envelope Designer Name: Lawrence C.Reeves Signature: NOT IN SCOPE Company: Lawrence C.Reeves, L.P. Address: 49-850 Jefferson St., Suite 130 Date Signed: City/State/Zip: Indio CA 92201 Declaration Statement Type: Phone: (818) 425-0830 Title: License #: Responsible Lighting Designer Name: Lawrence C.Reeves ignature: Company: Lawrence C.Reeves, L.P. Address: 49-850 Jefferson St., Suite 130 Date Signed: City/State/Zip: Indio CA 92201 Declaration Statement Type: Phone: (818) 425-0830 Title: License #: Responsible Mechanical Designer Name: Tim Scott 1 Signature: Company: Scott Design and Title 24, Inc. ltz:�Z!' �6/iJGw�-�— Address: 77085 Michigan Drive Date Signed: City/State/Zip: Palm Desert CA 92211 Declaration Statement Type: Phone: (760) 200-4780 Title: License #: CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC PRF-01-E Page 14 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x NRCC-PRF-ENV-DETAILS -SECTION START A. OPAQUE SURFACE ASSEMBLY DETAILS Confirmed 1. 2. 3•. 4. o9i N T � c Surface Name Surface Type Description of Assembly Layers Notes Plywood - 5/8 in. R-30 Roof9 Roof Glass fiber batt - 10 in. R30 (CEC Default) ❑ ❑ Air - Cavity - Wall Roof Ceiling - 4 in. or more HB Part. Brd - 3/4 in. Stucco - 7/8 in. R 19 Wall (W.19.2x6.16)11 ExteriorWall Vapor permeable felt - 1/8 in. ❑ Wood framed wall, 16in. OC, 5.5in., R-19 Gypsum Board - 1/2 in. Stucco - 7/8 in. R-11 Wall Partition18 ExteriorWall Vapor permeable felt -1/8 in. ❑ ❑ Wood framed wall, 16in. OC, 3.5in., R-11 Gypsum Board - 1/2 in. Slab Type = UnheatedSlabOnGrade Slab On Grade28 UndergroundFloor Insulation Orientation = None ❑ ❑ Insulation R-Value = RO B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E) This Section Does Not Apply Confirmed C. OPAQUE DOOR SUMMARY 1. 2. 3. 4. S. 6. 7, Opaque Door Assembly Name Door Type Certification Method Operation Area Overall Status 1 Pass Fail / Tag or I.D. U-factor Insulated Metal Door16 Metal UninsulatedSingleLayerpoor DefaultPerformance Swinging 20 0.079 E ❑ ❑ 1 Status: N- New, A —Altered, E—Existing CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 15 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x NRCC-PRF-MCH-DETAILS -SECTION START A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2016-NRCC-MCH-03-E) Confirmed 1. DESIGN AIR FLOWS 2. VENTILATION (§ 120.1) y �_ 3 3 p m 3 z A m D O 1 z �+ z a z z T _ T v v < z v 3 Z `—^ 0 z v < �, G1 z y it r ` V A �� OC �� C O$ C n Z 1 O rn z Z n< T Z m 1 Z < m 70 n Ato 9 r CONDITIONED A o T n — O n �+ O _ Lr �+ _ O m 3 1 3 3 i a �^, Z n < 3 3, 1.0 E. ZONE NAME o r- 3 a 7° rl� n rn e�-ai �° O v m O M rn 3 _n ° �< n�" A Na o O z �£ ? 3 z°z1 ai °z ai v a M m= o �3 a a a z v o n ° r o 3 c 3 a a z m z 3 3 � 1-Tenant AC 1- 4 1,800 NA NA NA NA N AC 1- 4 3,221 NA 16 30.0 483 483 NA N NA ❑ ❑ Improvement TOTAL 3,221 NA NA I NA NA ❑ ❑ B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY § 140.4 1. 2. 3. 4. 5. 6. 7. S. Confirmed Rated Capacity Airflow (cfm) Fan (kBtuh) v n System ID System Type Qty Economizer Zone Name N a)Heating Cooling Design Min. Min. Ratio BHP Cycles ECM Motor 1-Tenant Uncontrolled 4 NA NA NA 1-Tenant Improvement 1800 NA NA NA NA ❑ El ❑ Improvement Trm C. EXHAUST FAN SUMMARY This Section Does Not Apply CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 16 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x D. DHW EQUIPMENT SUMMARY- (Adapted from NRCC-PLB-01) § 110.3 Confirmed 1. 2. 3. 4. S. 6. 7. B. 9. 10. 11. 12. Heater Tank Tank DHW Name Element Tank Type Qty Tank Vol Rated Input Efficiency Insulation Pilot Energy Standby Loss Heat Pump Location or - Type (gal) (kBtu/h) R-value (Btu/h) Type Ambient (Int/Ext) Condition AO SMITH EUF-06.2 Electricity Storage 3 17 15 EF:0.950 NA 0.027 NA NA ❑ ❑ E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS This Section Does Not Apply F. SOLAR HOT WATER HEATING SUMMARY (Adapted from NRCC-STH-01) This Section Does Not Apply G. MECHANICAL HVAC ACCEPTANCE TESTS & FORMS (Adapted from 2016-NRCC-MCH-01-E) § RA4 Declaration of Required Acceptance Certificates (NRCA) - Acceptance Certificates that may be submitted. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description n x n x n x n x n x n x n x n x n x n x n x n x n x n x n x n x n x Confirmed 6 o W O A o W 6 0% 6 V pp 00 0 w r O r+ 1+ f+ N W ? r N r Cr � V r 00 a a a a a a a a a a a a a a a a m to D o c 13 O o°a— D 0 o c < m � a o O v c. ° m x o M a Equipment N q 3 < n n m o m `^ n (D fD Requiring # of °- o N N v < rD ( o o 3 N v o' x fD m Testing or units o ° ° fD v rD n n < „ O1 c m °; ;: r� ' Ei o •'* o � 0 x rD o oa ran 3 o r��o 3 N m H °' = Verification D C c a iu — rD „ — a r„ a in o y .+ o a < 3 o s .-: or s v z a CL " R� rD Res DHW1 1 -- - I - ❑ ❑ SHW AC1-4 4 - - - ❑ ❑ CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 17 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x H. EVAPORATIVE COOLER SUMMARY This Section Does Not Apply NRCC-PRF-LTI-DETAILS -SECTION START - A. INDOOR CONDITIONED LIGHTING CONTROL CREDITS (Adapted from NRCC-LTI-02-E) § 140.6 Lighting Control Credits Schedule (includes all lighting controls installed in conditioned space for Control Credit Calculation Confirmed compliance credit per §140.6(a)2 and Table 140.6-A) 4 If Acceptance Test Required 4 Location in Occupancy Type (must meet Type/Description of Lighting Watts of Power Control Credit Building requirements of Table 140.6 A) Control (i.e., partial on occupancy # of Units Controlled Adjustment Watts sensor, manual dimming, etc.) Lighting Factor Pass Fail S-1-Tenant Medical and Clinical Care -none specified - 1 0.00 0 El El Improvement S-1-Tenant Medical and Clinical Care -none specified - 1 0.00 0 ❑ ❑ Improvement S-1-Tenant Medical and Clinical Care - none specified - 1 0.00 0 ❑ ❑ Improvement B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) I § 130.1 1 I This Section Does Not Apply I §130.1 M = Manual area controls; §130.00) = Mu111 Level; §130.lfc) = Auto Shut -Off.• §130.1 jd] = Mandatory ❑aylfyhr; §330.2 je] = Demand ReSpanslve C. TAILORED METHOD CONDITIONED LIGHTING POWER ALLOWANCE SUMMARY AND CHECKLIST (Adapted from NRCC-LTI-04-E) § 140.6 General lighting power (see Table D) 0 General lighting power from special function areas (see Table E) NA Additional "use it or lose it" (See Table G) 0 Total watts - 0 i D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) § 140.6-D This Section Does Not Apply CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 18 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time: 16:45, Tue, Jul 25, 2017 Compliance Scope: ExistingAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E) § 140.6(c) 3H Room Number Primary Function Area Illuminance Value (LUX) Room Cavity Ratio (Table G) Allowed LPD Floor Area (ft') Allowed Watts Confirmed Pass Fail NA NA NA NA NA NA NA ❑ ❑ IVOte: lalfarCa Nf@Cnaa jar �pCclaf 1-Unction areas Is not carren Ely fmpfementea F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E) Rectangular Spaces Room Number Task/Activity Description Room Length (ft) Room Width (ft) Room Cavity Height (ft) RCR Confirmed Pass Fail NA NA NA NA NA NA ❑ ❑ Non -Rectangular Spaces This Section Does Not Apply Noie: All applicable spaces are Uved under the Non -Rectangular Spaces table G. ADDITIONAL "USE IT OR LOSE IT" (Adapted from NRCC-LTI-04-E) 1. 2. 3. 4. Allowed Watts Confirmed Wall Display Combined Floor Display and Task Lighting Combined Ornamental and Special Effects Lighting Very Valuable Merchandise Mi o N = 0 0 0 0 0 ❑ ❑ S. Wall Display This Section Does Not Apply 6. Floor Display and Task Lighting This Section Does Not Apply 7. Combined Ornamental and Special Effects Lighting This Section Does Not Apply J CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 Project Name: Tenant Improvement NRCC-PRF-01-E Page 19 of 19 Project Address: 79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time'. 16:45, Tue, Jul 25, 2017 Compliance Scope: Exist! ngAlteration Input File Name: Desert Vein TI-La Quinta-TCZ-17.cibdl6x 8. Very Valuable Merchandise This Section Does Not Apply H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E) I § 130.4 Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify). Test Description Indoor Outdoor Confirmed NRCA-LTI-02-A NRCA-LTI-03-A NRCA-LTI-04-A NRCA-LTO-02-A Equipment Requiring Testing or Verification # of units Occ Sensors / Auto Time Switch Auto Daylight Demand Responsive Outdoor Controls a oT, Occupant Sensors 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Time Switch 0 ❑ ❑ ❑ ❑ ❑ ❑ Automatic Daylighting 0 ❑ ❑ ❑ ❑ ❑ ❑ Demand Responsive 0 ❑ ❑ ❑ ❑ ❑ ❑ Outdoor Controls 0 ❑ ❑ ❑ ❑ ❑ ❑ Lighting Controls, shown on plans, comply with the requirements of Title 24, California Energy Code. CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-07122017-4377 Report Generated at: 2017-07-25 16:45:27 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV-MM Project Name Date Desert Vein & Vascular Institute TI 712512017 DESCRIPTION Building Envelope Measures: §110.8(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §110.8(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §110.8(g): Heated slab floors shall be insulated according to the requirements in Table 110.8-A. §110.7(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.z of §110.6(a): window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors (swinging and sliding), and 1.0 cfm/ft.Z for nonresidential double doors (swinging). §110.6(a): Fenestration U-factor shall be rated in accordance with NFRC 100, or the applicable default U-factor. §110.6(a) Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the applicable default SHGC. §110.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). The opaque portions of the roof/ceiling that separates conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-Factor requirements as follows: §120.7(a): Metal Building- The weighted average U-factor of the roof assembly shall not exceed 0.098. Wood Framed and Others- The weighted avers a U-factor of the roof assembly shall not exceed 0.075. The opaque portions of walls that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-factor as follows: Metal Building- The weighted average U-factor of the wall assembly shall not exceed 0.113. Metal Framed- The weighted average U-factor of the wall assembly shall not exceed 0.151. Light Mass Walls- A 6 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed 0.440. §120.7(b): Heavy Mass Walls- An 8 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed 0.690. Wood Framed and Others- The weighted average U-factor of the wall assembly shall not exceed 0.110. Spandrel Panels and Opaque Curtain Wall- The weighted average U-factor of the spandrel panels and opaque curtain wall assembly shall not exceed 0.280. Demising Walls-. The opaque portions of framed demising walls shall meet the requirements of Item A or B below: A. Wood framed walls shall be insulated to meet a U-factor not greater than 0.099. B. Metal Framed walls shall be insulated to meet a U-factor not greater than 0.151. The opaque portions of floors and soffits that separate conditioned spaces from unconditioned spaces or ambient air shall meet the applicable U-Factor requirements as follows: §120.7(c): Raised Mass Floors- Shall have a minimum of 3 inches of lightweight concrete over a metal deck or the weighted average U-factor of the floor assembly shall not exceed 0.269. Other Floors -The weighted average U-factor of the floor assembly shall not exceed 0.071. 'STATE OF CALIFORNIA Electrical Power Distribution CEC-NRCC-ELC-01-E (Revised 0 V16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 1 of 6) Project Name: Desert Vein & Vascular Institute TI Date Prepared: 7/25/2017 General Information Project Address: 79440 Corporate Center Way, Suite 119 Climate Zone: 15 Conditioned Floor Area: 3,221 Unconditioned Floor Area: 0 Building Type: 0 Nonresidential ❑ Schools ❑ High -Rise Residential ❑ ❑ Relocatable Public Schools Hotel/Motel Phase of Construction: ❑ New Construction ❑ Addition ® Alteration In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility reported by this certificate. Use additional pages as needed to list all construction documents related to compliance of Section 130.5. Document Number Document Title / Descriptions (include description information for Table or Schedule if it contains compliance information) Document Sheet # or Page # Indicate which subsection of Section 130.5 is related to the document (e.g. 130.5(a) for service electrical metering) Ell, E2 & E3 Lighting, Power, Panel for the TI CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA Electrical Power Distribution CEC-NRCC-ELC-01-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 2 of 6) Protect Name: Date Prepared: Desert Vein & Vascular Institute TI 7/25/2017 Document Title / Descriptions Applicable Document Sheet # Document Number (include description information for Table or or Page # subsection of Schedule if it contains compliance information) Section 130.5 I CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE 61� CALIFORNIA Electrical Power Distribution CEC-NRCC-ELC-01-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 3 of 6) Project Name: Desert Vein & Vascular Institute TI Date Prepared: 7/25/2017 A. Service Electrical Metering Check one of the three boxes below if the electrical power distribution system is in compliance with Section 130.5(a). ❑ For newly installed electrical service in newly constructed buildings, Service Electrical Metering is required according to Section 130.5(a). Fill out Column 1 thru 6 of table below. l For new or replacement electrical service equipment in existing buildings, Service Electrical Metering is required according to Section 141.0(b)2Pi. Fill out Column 1 thru 6 of table below. ❑ EXCEPTION to Electrical Service Metering: Service or feeder for which the utility company provides a metering system that indicates instantaneous kW demand and kWh for a utility -defined period. Fill out Column 1, 2 and 6 of table below with the compliance information. Fill out a separate line for each electrical service that is connected to the building. If additional table space is needed for electrical service information, submit additional page with the information. Electrical Metering Capabilities Exception to Electrical Service Schedule Service Field Inspector (check all that are present) 130.5(a) Rating 01 02 03 04 05 06 07 08 °w Y L N bo C E +r 3 a m Nov ro o oo .0 v v o +; E tv v Check that the Y Y _ C J m a OJ E +' N metering complies Electrical Service o a ° a _— Designation/Location/Description kVA — 200 Amp Panel 61.97 ° ° ❑ ❑ ❑ ❑ ❑ ❑ CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA Electrical Power Distribution CEC-NRCC-ELC-01-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION 3e CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 4 of 6) Project Name. Desert Vein & Vascular Institute TI Date Prepared: 7/25/201 r B. Separation of Electrical Circuits for Electrical Energy Monitoring Check all boxes below if the electrical power distribution system is in compliance with Section 130.5(b). 1H The electrical power distribution system meets the separation of electrical circuits for electrical energy monitoring requirement of Section 130.5(b). The electrical power distribution systems is designed so that measurement devices can monitor the electrical energy usage of load types according to TABLE 130.5-B. I$ Describe the electrical power distribution system installed and the compliance method chosen in meeting the requirement of Section 130.5(b). Use the space below to include the information. Examples of compliance methods are detailed in Nonresidential Compliance Manual Chapter 8. Fill out Column 1 thru 3 with the compliance information. Electrical Power Distribution System information and Method of Electrical Service Enforcement General information compliance Rating Agency 01 02 03 04 Electrical Service Describe the electrical power distribution system installed and the WA Check that the Designation/Location/Descrip compliance method used. system complies tion F200 AMP Sub -Panel 120/208 V distribution system 61.97 Field Inspector Notes: CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA Electrical Power Distribution SEC-NRCC-ELG-01-E(ReMe[I01115) UALWUKIVW tlVtKliT l VMIVIIJJIVIV �� CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 5 of 6) Project Name: Date Prepared: Desert Vein &Vascular Institute TI 7/25/2017 C. Voltage Drop Enforcement Agency Check all boxes below if the electrical power distribution system is in compliance with Section 130.5(c). Check that the system complies g1 The electrical power distribution system meets the voltage drop requirement of Section 130.5(c). The maximum combined voltage drop on feeder conductors and branch circuit conductors to the farthest connected load or ❑ outlet, do not exceed 5%. gl Voltage drop calculation documents showing compliance to Section 130.5(c) are submitted as part of the ❑ compliance document submittal. D. Circuit Controls for 120-Volt Receptacles and Controlled Receptacles Field Inspector Check one or more boxes below for applicable requirements of Section 130.5(d) for the electrical power distribution Cehck that the system system. complies )1�1 The control is capable of automatically shutting OFF the controlled receptacles when the space is typically unoccupied, either at the receptacle or circuit level. For the automatic time switch control, it incorporates an override control that allows the controlled receptacle to remain ON for no more than 2 hours when an override is initiated and an automatic holiday "shut -OFF" feature that turns OFF all loads for at least 24 hours and then resumes the normally scheduled operation. Countdown timer switches are not be used to comply with the automatic time switch control requirements. The controls meet the requirement of Section 130.5(d)1. ❑ There is at least one controlled receptacle within 6 ft from each uncontrolled receptacle. Where receptacles are installed in modular furniture in open office area, at least one controlled receptacle is installed at each ❑ workstation. The receptacles meet the requirement of Section 130.5(d)2. ❑ There are installed split wired receptacles with at least one controlled and one uncontrolled receptacle. Where receptacles are installed in modular furniture in open office area, at least one controlled receptacle is installed ❑ at each workstation. The receptacles meet the requirement of Section 130.5(d)2. $1 Permanent and durable marking for controlled receptacles or circuits to differentiate them from uncontrolled ❑ receptacles or circuits is provided. The markings meet the requirement of Section 130.5(d)3. ❑ For hotel and motel guest rooms, there are controlled receptacles for at least one-half of the 120-volt receptacles in each guest room. Electric circuits serving controlled receptacles in guestrooms are installed to have captive key controls, occupancy sensing controls, or automatic controls so the power is switched off no longer than 30 minutes after the guest room has been vacated. The receptacles meet the requirement of Section 130.5(d)4. ❑ Receptacles that are only for the following purposes are excepted from Section 130.5(d): -Receptacles specifically for refrigerators and water dispensers in kitchen areas. -Receptacles located a minimum of six ft above the floor that are specifically for clocks. -Receptacles for network copiers, fax machines, A/V and data equipment other than personal computers in copy rooms. ❑ -Receptacles on circuits rated more than 20 amperes. -Receptacles connected to an uninterruptible power supply (UPS) that are intended to be in continuous use, 24 hours per day/365 days per year, and are marked to differentiate them from other uncontrolled receptacles or circuits. CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA Electrical Power Distribution CEC-NRCC-ELC-01-E (Revised 01116) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E Electrical Power Distribution (Page 6 of 6) Project Name: Date Prepared: 7/25/201 7 Desert Vein &Vascular Institute TI DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tim Scott Documentation Author Signature: Company: Scott Design and Title 24, Inc, Signature Date: 7/25/2017 Address: 74-818 Velie Way, Suite #8 CEA/ HERS Certification Identification (if applicable): City/state/zip: Palm Desert, CA 92260 Phone` (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approvai with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Lawrence C.Reeves Responsible Designer Signature: Company : Lawrence C.Reeves, L.P. Date Signed: Address: 49-850 Jefferson St., Suite 130 License: City/State/Zip: Indio, CA 92201 Phone: (818) 425-0830 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Desert Vein & Vascular Institute TI Date 7/25/2017 System Name AC 1 -4 Floor Area 3,221 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 4 COIL CFM Total Room Loads 6,286 Return Vented Lighting Return Air Ducts Return Fan Ventilation 483 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 54,000 113,368 12,153 2,098 31.823 Total Output Btuh) 216,000 0 Output Btuh/s ft 67.1 5,668 1,591 Cooling Sys m o 0 Output per System 53,000 17,606 6,574 483 22,517 Total Output (Btuh) 212,000 0 18,727 0 Total Output (Tons) 17.7 5,668 1,591 Total Output Btuh/sgft 65.8 Total Output s ft/Ton 182.3 142,311 57,522 Air System CFM per System 1,800 HVAC EQUIPMENT SELECTION Airflow cfm 7,200 Existing York HVAC 158,790 31,444 134,908 Airflow (cfm/sgft) 2.24 Airflow (cfm/Ton) 407.5 Outside Air (%) 6.7 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 158,790 31,444 134,908 Jan 1 AM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions Aug 4 PM HEATING SYSTEM PSYCHROMETRICS jAirstream Temperatures at Time of Heating Peak 26 OF 0-0- 10 Outside Air 483 cfm 70 OF 67 OF 84 OF 84 OF f Cry F���i 08 Heating Coil Supply Fan 7,200 cfm l ( 1p 0 84 F ROOM 70 OF COOLING SYSTEM PSYCHROMETRIGS Airstream Temperatures at Time of Cooling Peak 111 / 78 IF Outside Air Ar 483 cfm 79 / 65 OF 58 / 57 OF 58 157 OF oT-1 Cooling Coil Supply Fan 7,200 cfm 1 U I 59 / 57 OF �---^ 52.3 % ROOM 76164 OF EnergyPro 7.1 by EnergySoft User Number: 6712 ID: Page 29 of 30 ZONE LOAD SUMMARY Project Name Desert Vein & Vascular Institute TI Date 712512017 System Name AC 1 - 4 Floor Area 3,221 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Tenant Improvement 1.0 483 Aug 4 PM 6,286 131,354 19,777 2,098 54,447 TOTALS 17 0 0 483 Aug 4 PM 131,354 19,777 54,447 (BLOCK LOAD) PnergyPro 7.1 by PnergyScft User Number. 6712 ID: Page 30 of 30 r1W1ZAAL : A� -" At. & 117 ZC4-/ (2ai-Otta PERMIT # PLAN LOCATION: 3A Project Address: 9 `C br c",�L{ Ch.i� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech g APN #: ed f'e- lec`�- Applicant Name: CG�+a ,',••. Q �GI l��`l0 �_a 5/< Address: 133.0 City, ST, Zip: % �v a >° , SeS ^ Z LJ CC_ Telephone: Email: Valuation of Project $ zo 00, 6 C Contractor Name: f�� K New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: Patio/Porch _ SF Email: Fire Sprinklers SF State Lic: City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: DEC 0 8 2017 CITY OF LA QUINTA COMMUNITY WVROPMENT 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal - Req'd. -Req'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License