BMCH2017-038878-495 CALLE TAMPICO
a�
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BMCH2O17-0388
Property Address:
APN:
53705 AVENIDA CORTEZ
774101015
n Q 0 I,t1
Application Description:
MANNING RESIDENCE / HVAC CHANGE
)19 TM
Property Zoning:
I
AUG 3 1 2017U
Application Valuation:
$22,938.00
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153 .
Owner:
JEFF MANNING
53705 AVENIDA =ORTEZ
LA QUINTA, CA 92253
Date: 8/31/2017
Applicant: CITYOFLAQUiNTA
COMMUNITY DEVELOPMENT DEPARTMENT Contractor:
IE INC HARRISON ENTERPRISES INC DBA GENERAL AIR
31225 LA BAYA 31170 RESERVE DRIVE
WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed -under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect. .
License Class: C20, C36 License No.: 686310
Date: 31 17 Contractor: �.Z�
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the.Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the.
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or.herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY'
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.)'.
Lender's
Lender's Address:
(760)343-7488
Llc. No.: 686310
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one c# the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 37x1 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the perfocmance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658
I certify that in the performance of -the work for which this permit is issued, I
shall not employ any person in any manner so!as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section =700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 18131 1'—) Applicant:
WARNING: FAILURE TO SECURE WORKERS' CCMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMIIIAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject -to
the conditions and restrictions set forth on thi: application.
1. Each person upon whose behalf this applkation is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the(City of La Quinta, its officers, agents, and
employees for any act or omission related to t ie work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of ssuance of such permit, or cessation of
work for 180 days will subject permit to cancef)ation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordi:iances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mehtioned property for inspection purposes.
e
Date: 31 1-1 Signature (Applicant orAgent):l
Date: 8/31/2017
Application Number: BMCH2O17-0388
Owner:
Property Address: 53705 AVENIDA CORTEZ
JEFF MANNING
APN: 774101015
53705 AVENIDA --ORTEZ
Application Description: MANNING RESIDENCE / HVAC CHANGE OUT
LA QUINTA, CA S2253
Property Zoning:
Application Valuation: $22,938.00
Applicant:
Contractor:
IE INC
HARRISON ENTERPRISES INC DBA GENERAL'AIR
31225 LA BAYA
31170 RESERVE DRIVE
WESTLAKE VILLAGE, CA 91362
THOUSAND PALMS, CA 92276
(760)343-7488
------------------------------------------------------------
Llc. No.: 686310
---------------------------------
Detail: HVAC CHANGE OUT AND 10 DUCTS - 20.SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION.
PER 2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE 101-0000-20306 .0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - REPAIR/ALTERATION
101-0000-42402
0
$12.67
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - REPAIR/ALTERATION PC
101-0000-42600
0
$5.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC'
101-0000-42600
0
$38.00
Total Paid for CHANGEOUT: $131.74
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$96.27
Total Paid for PERMIT ISSUANCE: $96.27
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
TOTALS: $234.01
r
i
art.#
cft} Of QU111#a
Building a Safety Division
P.O. Box 1504, '78-495 Calle Tampico
1.a.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: 53705 Avenida Cortez
Owner's Name: Jeff Manning
A P. Number.
Address: 53705 Avenida Cortez
Legal Description:
City; ST, Zip: La Quinta, CA 92253
Contractor. General Air Conditioning
s
Telephone: 760-831-1756
Address: 31170, Reserve Drive
Project Description: Replace 4 ton heal pump, air handler &
City, ST, Zip: Thousand Palms, CA 92276
10 ducts
Telephone: 760-343-7488
State Lic. # : 686310
City Lia fl:
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
State Lia #:'' ,
Mss.
Name of Conts4t Person: Steven Schnierer
Construction Type: . Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft : # Stories: —T—Units:
Telephone # of Contact Person: 818-735-7876
Estimated Value of Project: $22,938.00, .
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACMG
PERIl41T FEES
Plan Sets
Plan Check submitted
item Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Cates.
Called Contact Person
Plan Check Balance
Tide 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
' Review, ready for corrections/isme
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IM HOUSE:-
'^' Review; ready for corrections/issuc
Developer Impact Fee
Planning Approval
Called Contact Person
Pub. Wks. Appr
Date of permit issue
School Fees
Total Perink Fees
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of 3)
Project Name: JEFF MANNING I Date Prepared: - . 2017-08-30 '1
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
O3
Project Name
JEFF MANNING
02
Date Prepared
2017-08-30
03
Project Location
53705 AVENIDA CORTEZ
04
Building Type
Single family
.05 '
CA City
La Quinta
06
Dwelling Unit Name
HOME
07
Zip Code
92253
08
Dwelling Unit Conditioned
1542
Installing
Installing
Installing
Floor Area (ft2)
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
f
Served
Number of Space
system?
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
SYSTEM 1
_
1542
Yes
this Dwelling Unit:
Yes
B. Space Conditioning (SC) System Information
ff- r --I .
01
02
03
04
05
f 06'
07
- 08
09
10
CFA
Is the SC�Installinga,
"Installing new SCS
SC System
SC System
served
a,_,
system
rgerant
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
WHOLE HOME
1542
Yes
Yes
Yes
Yes
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 417-A020113140A-000-000-0000000-0000 Registration Date/Time: 2017-08-30 12:35:17 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-30 12:35:17
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
01
.02
03
04
0S
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central gas
All new
en
Central split
All new
Greater than
SYSTEM 1
furnace
heating
AFUE
0.8
AC
cooling
SEER
20
Setback
40 feet
R-8
components
components
Required Documentation:'
CF2R-MCH-01-E - Space Conditioning Systems ) � ` �`° :
€ { •,
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums }R6 -(CZ 1 10 12 a6613) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of dud length is replaced
-Leakage rate compliance: <=15% or <= 10% leakage to outside, or seal all accessible leaks. '" (' `�3
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components cretins tilled or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
7r — . tILJ1 jc:.: Imo-, t if` y� (C7
E. Entirely New or Complete Replacement Duct System, with or without Equipment Chan a ui (Sections 150.2 b 1Diia and 150.2 b 1E F)
i 'This section d es no a ply toth prolect.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 417-A020113140A-000-000-0000000-0000 Registration Date/Time: 2017-08-30 12:35:17 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-30 12:35:17
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Salvador Correa
SabvaAarCorrew
Company:
Signature Date:
I Permit E Raters
2017-08-30
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
RCN13245
City/State/Zip:.
Phone:
Westlake Village CA 91362x°. (}
818,.735-7876
Responsible Person's Declaration.statement�/``+wJ',�'i
I certify the following under penalty of perjury, under the laws of the State of California:. �4. � (-•, if ' ,r
1. The information provided on this Certificate of Compliance is true and correct. ?
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design Identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for -approval with this building permit application.
,i- %Wl _. l y4�. >f. 0 JL ES,.
S. I will ensure that a registered copy of this Certificate of Compliance shall available�with the l5uilding:permit(s) sued for the building, and made available to the enforcement agency for all applicable
�be.made
inspections. I understand that a registered copy.of this Certificate of Compliance is,required`'to be included witts'the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:Responsible;DeY
Patrick Somers Unmatthed rsii
igne�r Signature:
Salvvad'oYC'orrri, �(aut3wrv�ed)
Company:
Date Signed:
General Air Conditioning
2017-08-30
Address:
License:
31170 Reserve Drive
686310
City/State/Zip: •
Phone:
Tltuusand Palms CA 92276
760-143-7488
Digitally signed by CHEERS'"'. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information..
Registration Number: 417-A020113140A-000-000-0000000-0000 Registration Date/Time: 2017-08-30 12:35:17 1 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-30 12:35:17
Schema Version: rev 10/16