Loading...
BRES2017-010178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: DESIGN & DEVELOPMENT DEPARTMENT . BUILDING PERMIT BRES2017-0101 53780 AVENIDA CORTEZ 774142002 STEMMER / 1,878 SF DWELLING/VB/RES-3/CLASS A-FR/13D $122,526.70 Applicant: BRIAN K STEMMER CONSTRUCTION 74478 HWY 111 # 322 PALM DESERT, CA 92260 D LJ JUN 3 0 2017 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 649172 atb— a ` t" 0 -7 n r ctor.,Sr OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 7774011 INSPECTIONS (760) 777-7153 Date: .6/30%2017 Owner: BRIAN STEMMER 74478 HIGHWAY 111 STE.322 PALM DESERT, CA 92260 Contractor: BRIAN K STEMMER CONSTRUCTION 74478 HWY 111 # 322 PALM DESERT, CA 92260 (760)819-5476 Llc. No.: 649172 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. hMlve and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: . Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9211726 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: — 61.11 PI pA plica. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. ' 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a resulfof this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ctuinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. n Dater 6/30/2017 Application Number: BRES2017-0101. Owner: Property Address: 53780 AVENIDA CORTEZ BRIAN STEMMER APN: 774142002 74478 HIGHWAY 111 STE 322 Application Description: STEMMER / 1,878 SF DWELLING/VB/RES-3/CLASS A-FR/131) PALM DESERT, CA 92260 Property Zoning: Application Valuation: $122,526.70 Applicant: Contractor: BRIAN K STEMMER CONSTRUCTION BRIAN K STEMMER CONSTRUCTION 74478 HWY 111 74478 HWY 111 # 322 # 322 PALM DESERT, CA 92260 PALM DESERT, CA 92260 (760)819-5476 Llc. No.: 649172 -------------------------------------------------------------------------------------------- Detail: 1,878 SF DWELLING- [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION 'ACCOUNT QTY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING:. $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $17.73 Total Paid for ELECTRICAL: $43.06 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $25.84 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $10.64 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00. DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-426000 $50.16 Total Paid for ELECTRICAL- NEW CONSTRUCTION: $238.64 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $38.00. DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $38.00 Total Paid for GRADING: $76.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC. 101-0000-42600 0 $5.07 DESCRIPTION ACCOUNT QTY AMOUNT 1 FURNACE 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $20.28 Total Paid for MECHANICAL: $215.36 DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2016 UPDATE 101-0000-20310 0 $508.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $508.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $543.32 Total Paid for NEW CONSTRUCTION PERMIT: $543.32 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $900.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $174.36 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,074.36 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $17.73 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $139.37 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $139.37 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT ROOF DRAIN 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $430.75 DESCRIPTION ACCOUNT QTY AMOUNT SMI -RESIDENTIAL 101-0000-20308 0 $15.93 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $15.93 DESCRIPTION ACCOUNT QTY AMOUNT. TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5:00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 Bit) /f Permit„ t Project Address: Qty.of La Qul.nta Building 8z• Safety Division 78-495 Calle Tampico La Quin ta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet A. P. Number: --7-7L( (l(`Z 6072,- Address: it( -4-79 ( OjZ 2 Legal Description: City, ST, Zip: n Co tractor:' C rr.i �N^ 1n i/ Telephone: � �S 7 Address: "�CQj��'t t(' 14--w i 13 ZL Project Description: tei R-1--,1 1 City- ST, Zip: Tel e h ne• P 0 � y bo -6 S Lic. #: Ll1 City Lc. #.- :ArchState Arch., ., Engr., Designer. Address: �� l City, ST, Zip": Telephone- Construction TYPe•h�^-' Occupancy: ,ic. State L#. Project type one): New Add'n Alter Repaira' r Demo. Name of Contact Person: W ��//� Sq. Ft.: �87z3 # Stories: # Units: Telephone # of Contact Person: —] 6,6 Estimated Value of Project. - APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item 'Amount Structural Cates. Reviewed; ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance, Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Dced Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact -Person A.I.P.P. Pub. \Vks. Appr Date of permit issue School Fees, Total Permit Fees c7-l�J^U` �J ` CERTIFICATE OF COMPLIANCE v��Fteo Desert Sands Unified School District 47950 Dune Palms Road yERMUDAOUNES -` � '!a La Quinta CA 92253 Date: 6/29/2017 � ' a `°MESE"-y � . COA ELIA ° 0 � No.: 17-00639-1 (760)771-8515 • Owner: Brian Stemmer Email: Address: 53780 Avenida Cortez Jurisdiction: La Quinta City: La Quinta, CA Tract #: Type: Single Family Residential Lot # Street No. Street Name Sq. Feet APN Permit No. 53780 Avenida Cortez 1878 774-142-002 JUN 3 0 2017 CITY OF LA QUINTA COMMUNr1 !DEVELOPMENT Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, res.r':. under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation:, mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following ray EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.48 X 1878 S.F. or $6,535.44 have been paid for the property listed above and that buildin ,, permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CC 1st Bank\Brian Stemmer Bank Name/Recipient of Certificate By Scott L. Ba i I ey Superintendent Check No.: 1436382 Telephone: 760-819-5476 Funding: Residential Fee Collected/ Exempted by: Virgilio Ga cia Certificate Fee s"D,y �,. Original PaymenT>>s) '77 r> New Payment F-},e'd ri .4 NOTICE: Pursuant to Government Code Section 66020(d)(1), this wiot%fyu that the 90 -day approval period in which you',n�� other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, dr, frar-?, 6 -' which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSS Lawyea Title RECORDING REQUESTED BY: Escrow Plus, Inc. Order No. 616696590 Escrow No. 34824H Parcel No. 774-142-002-7 AND WHEN R.ECORDE BRIAN K. STENME 74478 Hwy 111 #322 Palm Desert, CA 92260 DOC # 2017-0111671 03/20/2017 02.53 PM Fees: $18.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "This document was electronically submitted to the County of Riverside for recording— Receipted by: LISA #580 LINE FOR GRANT DEED J THE UNDERSIGNED GRANTOR(S) DECLARE(S) THAT DOCUMENTARY TRANSFER TAX IS $84.70 and CEIVED computed on full value of property conveyed, or� ❑ computed on full valueless liens or encumbrances remaining at the time of sale. ❑ unincorporated area: ® La Quints, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, JUN 3 0 2017 Donley Van Malsen, an unmarried man hereby GRANT(S) to Brian K Stemmer, an unmarried man CIT( OF LA QUINTA the following described real property in the County of Riverside, State of California: COMMUNITY DEVELOPMENT Lot: 23 Block: 197 Abbreviated Description: LOT'2,kBLK: 197 MB 029/033 SANTA CAR'sqELITA AT VALE LA QUINTA UNIT 19 City/Muni/'Twp: LA QUINTA Date February 28, 2017 —71 See attached Exhibit °A° for complete legal Donley Van Malsen A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA COUNTY OF jUk6jE s I D C= } S.S. On before personally appearedA — S4- %7 who proved to me on a basis of fa `t ry evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/sheAky executed the same in his/herltheir authorized capacity(ies), and that by hisawrkheir signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. NAYAN P. GHELANI '&_ Umk COMM. #2174611 Signature �_ (Seal)NotaryPublic Callforttla I RIVERSIDE N WMy App. 6Oas Dec. 31, 2020 Mail Tax Statement to: SAME AS ABOVE or Address Noted Below YOUNG •< , . ripEN�GCNEERLNG a. a m: ° 6 .u.. Letter. of Transmittal` •' To: City of La, Quinta Today's Date • ' ., 6-27-17 78-495 Calle Tampico City Due Date: ' 6-28-17 V La Quinta, CA 92253 Project Address:: 53780 Avenida Cortez Attn: , MARY Plan Check #: BRES2017-0101 - - - Submittal: 1 st # ❑ 4th 2nd 5U'' ❑ 3rd, . ❑ Other: # Weare forwarding: ❑ By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes:Descriptions: Includes: # Of M Descriptions: Copies: ❑ Structural Plans ❑ Revised Struct. Plans . O Structural Calculations ❑ Revised Struct. 'Calcs ❑ Truss Calcs ❑ . Revised Truss Calcs ❑ Soils Report - Update ❑ Revised Soils Report ❑ Structural P/C Responses - O Approved Structural Plans y 1 /Comments 1 El.1 Redlined Structural Plans D 1- Approved Structural Calcs D 1 Redlined Structural Calcs ❑ 1 Approved Truss Calcs 0 1 Redlined Truss Calcs 0 Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. Transit Per Diem= ti Admin Time = 0.25 hrs. Structural Engineer/Principal Review Time, = 0.0 ; hrs. Plan Review Engineer,Time = 1.0 hrs. • This Material Sent for: ❑ Your Files Q Per Your Request ❑ Your Review ❑ : Approval ; ElChecking • ❑ At the request of: �. Other: ❑ By:. Joe Venuti Office : Q (760) 772-5107 *' Other: E LQPC@VALUENGR.COM d Building Permit Number. S C —Q? Project De tion:- SFJ "Exempt.O atedals may contain h rdous wastes and are not subject to recycling provisions) - Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owners Phone Number Owners E -Mail Address Project Managers Name Project Managers Phone Number Project Managers E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage City Approval By 6/29/2017 53780 Avd. Cortez Stemmer, Brian 74478 Hwy 111, #322 Palm Desert, CA 92260 760-819-5476 bkstemmor@hotmaii.com Stemmer, Brian 760-819-5476 bkstemmer®hotmail.com Stemmer, Brian 74478 Hwy 111, #322 Palm Desert, CA 92260 1,800 '?ECEIVED JUN 3 0 2017 COMM �� QUIN7-q . EVELO pMEV T Date of City Approval Materials To Be Discarded: Product Tons Trash 3.42 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Recyclable BrickBlock 0.00 Recyclable _ Plaster 0.36 Recyclable Cardboard 0.59 Recyclable Scrap Metal 0.00 Recyclable Commingled 0.00 Recyclable Tile (floor) 0.31 Recyclable Concrete 0.14 Recyclable Tile (roof) 0.00 Recyclable Drywall 0.11 Recyclable Wood 4.50 Recyclable Donated /Reuse' 0.00 Recyclable Landscape Debris 0.00 Recyclable 'Describe Items - - Totals: Recycle, Trash . ProjectedDiversion: ` 6.0 3.4 63.7% I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted �+ from landfilling. The remaining material will be recycled or /eused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is ,+ Issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition` project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are . adhered to. The property owner(s) and general contractor shall be kept informed of the diversfon,progress through bi-monthlyP`. r rts. If sel hauling, all refuse material from this project site must be taken to an approved recycler or transfer station.' 3.0 t Owner/ Develo er / Project Manager/ Superintendent Date i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD ` CF1 R -PRF -01 Project Name: STEMMER RESIDENCE Calculation Date i 1(6:48, Wed, Jun 14, 2017 Page 1 of 9 Calculation Description: Title 24 Analysis Input Fiill Na rr> - ` AVENIDA CORTEZ.ribdl6x GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name S T E M M E R R E S I D E N 04 05 02 Calculation Description Title 24 Analysis Q` Energy Use (kTDV/ft2-yr) 03 Project Location AVENIDA CORTEZ Compliance Margin Percent Improvement 04 City LA QUINTA tandards Version Compliance 2017 06 Zip Code 92253 nce Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 Software Version CBECC-Res 2016.2.1 (868) 10 Building Type Single Family !Front Orientation (deg/Cardinal) 270 12 Project Scope Newly Constructed Q► 3 of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1878 Jl Number of Zones 1 16 Slab Area (ft2) 1878 17 �l Number of Stories 1 18 Addition Cond. Floor Area n/a Natural Gas Available Yes 20 Addition Slab Area{f42) n/a 21 Glazing Percentage (%) 12.9% COMPLIANCE RESULTS 01 Building Complies with'Computer P,erforman ce '�. T4 rot. .y�g, �. :'k �.*•}an;/.'1! �tg "�.. Q:4 02 This building incorporates features.that require field testing-and/ori erificatioRby a{certified4HERS ateriunder he supervision of a CEC-approved HERS provider. 03 This building -incorporates one�ormore Speclal=Features-shown- below VE JUN y 5 2017 p CITY OF L4 QUINTq . Registration Number: 217-Pot0201561A-000-000-0000000-0000 Registration Date/Time: 2017-06-14 IANMING DEggRTME[ Rs Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 port Generated at: 2017-06-14 16:49:04 UA ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.24 3.74 -3.50 .1458.3% Space Cooling 79.49 63.70 15.79 19.9% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 6.82 12.39 -5.57 -81.7% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 87.74 81.02 6.72 7.7% VE JUN y 5 2017 p CITY OF L4 QUINTq . Registration Number: 217-Pot0201561A-000-000-0000000-0000 Registration Date/Time: 2017-06-14 IANMING DEggRTME[ Rs Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 port Generated at: 2017-06-14 16:49:04 UA CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribd16x CF1R-PRF-01 Page 2 of 9 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Design EDR of Proposed Design EDR Value of Proposed PV Final EDR of Proposed Design 53.7 50.9 0.0 50.9 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site HERS FEATURE SUMMARY photovoltaic (PV) renewable energy, generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. REQUIRED SPECIAL FEATURES;' The following are features that must be installed as condition formeeting^the modeled energyperformanceforthis;computer analysis. • Cool roof t' • Insulation below roof deck - r�dtL K • Window overhangs and/or fins '',: • Exposed slab floor in conditioned zone, HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow A • Verified EER • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: -- None -- Registration Number: 217-P010201561A-000-000-0000000-0000 Registration DateMme: 2017-06-14 16:59:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Input File Name: 2R-023 - AVENIDA CORTEZ.ribdl6x CF1 R -PRF -01 Page 3 of 9 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems STEMMER RESIDENCE 1878 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 (N) 1878 Conditioned HVAC1 1878 8 DHW Sys 1 ' . (N),,1878 R-15 Wall + 0 OPAQUE SURFACES A 01 r ''.. 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N - 518 ' . (N),,1878 R-15 Wall + 0 Left 518 12 90 E- 400 (N) 1878 " , yyR-1a5;IWall ; 90# Back 400 53 90 S- 518 , (N),1878 R-15j1Nall} 1' ; X180 :f Right 518 46 90 W- 400. ' • (N)r1878 } + 270 R;15YWallk :,-7 }}FroriY I t a'i 400 152.58 90 1878 (N)1878 R-38 + R-11 (. :I ;r E i p 1878 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic (N) 1878 Attic Roof(N) 1878 Ventilated 0.2 0.86 0.88 No Yes Registration Number: 217-P010201561A-000-000-0000000-0000 Registration Date/Time: 2017-06-14 16:59:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribd16x CF1 R -PRF -01 Page 4 of 9 FENESTRATION / GLAZING 01 4 t-1 41."'# $' 02 V 9 tt t 03 04 Name Side of Building Area (ft2) U -factor 2880 W- 400 21.3 0.50 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading 4010-1 Window N - 518 (Left -0) 4.0 1.0 1 4.0 0.37 0.25 Insect Screen (default) 4010-2 Window N - 518 (Left -0) 4.0 1.0 1 4.0 0.37 0.25 Insect Screen (default) 5080-3 Window N - 518 (Left -0) 5.0 8.0 0.1 4.0 0.48 .4 0.25 Insect Screen (default) 5010-4 Window E- 400 (Back -90) 5.0 1.0 1 5.0 0.44. 0.25 Insect Screen (default) 6080-5 Window E- 400 (Back -90) 6.0 8.0 1 48.0 0.48 ,0 0.25 Insect Screen (default) 4050-6 Window S- 518 (Right -180) 4.0 5.0 1 20.0 0.44 0.25 Insect Screen (default) 4016-7 Window S- 518 (Right -180) 4.0 1.5 1 6.0 0.44 0.25 Insect Screen (default) 4050-8 Window S- 518 (Right -180) 4.0 5.0 1 20.0 0.44 0.25 Insect Screen (default) 3076-9 Window `, W- 400 (Front -270) 3.0 7.5 1 22.5 0.37.-1 0.25 Insect Screen (default) 12676-10 Window W- 400 (Front -270) 12.5 7.5 1 93.8 0.48 0.25 Insect Screen (default) 3010-11 Window W- 406 (Front -270) 3.0 1.0 1 3.0 0.37 0.25 Insect Screen (default) 6010-12 Window Y , W= 4 -00 (Front -270 X6.0 0,1 _6.0 0.37 0.25 Insect Screen (default) 6010-13 Window QW- 400 (Front 276) 1= ' .." io.Q1 f X6.0 1 ' 0.141 f 6.0 0.37 0.25 Insect Screen (default) OPAQUE DOORS x � ,ice �, � �. -sem ,rte. � r ad 01 4 t-1 41."'# $' 02 V 9 tt t 03 04 Name Side of Building Area (ft2) U -factor 2880 W- 400 21.3 0.50 Registration Number: 217-P010201561A-000-000-0000000-0000 Registration Dateffime: 2017-06-14 16:59:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribd16x CF1 R -PRF -01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang • Cavity/Frame: R-11 /2x4 Top Chrd Left Fin 2x4 Top Chord of Roof Truss @ 24 Right Fin Roof Deck: Wood Siding/sheathing/decking Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 4010-1 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4010-2 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 5080-3 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 5010-4 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 6080-5 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4050-6 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4016-7 1.5 r'- 0.1 4 4 0 0 0 0 0 10 0 0 0 4050-8 1.5' . '; 0.1 4 4 0 0 0 0 0 0 0 0 0 3076-9 10 ;` 1' 0.1 10 10 0 0 0 0 0 0 0 0 0 12676-10 7" 10 '" ' 0.1' �, 10 ` 10 0 0 0 0 0 0 0 0 0 3010-11 10 ;-- 0.1X10 1:9=*�0; -n r..0: 0 fT 0 0 0 0 0 0 6010-12 10 g'�0.1 4:1 10 1110 f 0 1 0 0; F 0 0 0 0 0 0 6010-13 ; 100.1 10 10, 0 0 0 0` 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS'' ' 4 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity/Frame: R-11 /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof(N) 1878 Attic Roofs Wood Framed Ceiling in. O.C. R11 0.088 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 + R-11 attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/ Frame: R-15 / 2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.095 Exterior Finish: 3 Coat Stucco Registration Number: P17-Po1o2o1561A-000-000-0000000-0000 Registration DateTme: 2017-06-14 16:59:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation DatelTime: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribdl6x CF1 R -PRF -01 Page 6 of 9 SLAB FLOORS 01 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated 18782 (N) 1878 1878 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 .. DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS - - 01 02 03 04 05 06 07 08 09 10 11 Air Distribution System 1 Heater r Number• Tank Vol a LEnergjr L Factor oinput T`nk Insulation R Standby Loss / Tank Location or Ambient Name Element Type Tank Type' of Units; ;-,.,(gal) Effieiencj�= ,..Ratmg%Pilot -value (Int/Ext)Recovery+Eff NEEA Heat Pump Type Condition 'N � i i ii R-0 n/a 0 n/a DHW Heater 1 Gas Small Storage 1 50., .57.5"17EF 4�0,000'Btu7hr n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC1 Other Heating and Cooling Heating Component 1 System Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Registration Number: 217-Po10201561A-000-000-0000000-0000 Registration Dateffime: 2017-06-14 16:59:27 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 C. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribd16x pow '' 1 H ;-� CF1R-PRF-01 Page 7 of 9 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 114 Required 16.5 Not Zonal Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02: `, 03 04 05 06 07 Name ,,• m -- -j. Type - - : _ Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Ve fled'Dact­* Design 1 Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Air Distribution System Air Distribution System 1 .DuctsAttic Sealed -and tested � 7,�""" r 8 ` Mt '9F Attic None 1 -hers -dist Y.. w 1 -7l <= HVAC DISTRIBUTION -HERS VERIFICATION 0102w . US r . 04 . X115 r F. �r 06 07 OS Name Duct Leakage Verification Duct�Leakage' Target (%) Verified'Duct` Location Ve fled'Dact­* Design 1 Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required --- HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 Registration Number: 217-PO10201561A-000-000-0000000-0000 Registration Date/Time: 2017-06-14 16:59:27 - HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL- PERFORMANCE COMPLIANCE METHOD ; ` 'CF1 R -PRF -01 Project Name: STEMMER RESIDENCE _ Calculation Date/Time: 16:48, Wed, Jun 14, 2017 • Page 8 of 9 Calculation Description: Title 24 Analysis - Input File Name: 2R-023-AVENIDA CORTEZ.ribdl6x - IAQ (Indoor Air Quality) FANS 01 - 02 03 - 04 05 06 Dwelling Unit - IAQ CFM • IAQ Wafts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification,,_ SFam IAQVentRpt -49 0.25 Default 0 Required = CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 16:48, Wed, Jun 14, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-023 - AVENIDA CORTEZ.ribdl6x CF1 R -PRF -01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ARMANDO CHAVEZ Company: Signature Date: TITLE 24 OF THE DESERT 2017-06-14 16:57:38 Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business"and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans ana specifications submitted�to.the enforcement,agency_for approvaltwith.ths.building permit application. Responsible Designer Name:t Responsible Designer Signature Ruben Romero ' Company: Date Signed: �,,,� 2R7 16.59:2 GLS ARCHITECTURE GROUP INC -Z714 Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-Po10201561A-000-000-0000000-0000 Registration ate Mme: 2017-06-14 16:59:27 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-06-14 16:49:04