Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FSS2017-0014
ucxt. Permit Details PERMIT NUMBER �� FSS2017-0014 ��- �=9�w� City of La Quinta 41OFn > 111.1. _ Description: CORDOVA/SPRINKLERS NEW SFD Process Summary Type: FIRE SPRINKLER Subtype: RESIDENTIAL-CUSTOM Status: FINALED Applied:7/18/2017 SKH HOMES Parcel No: 774142002 Site Address: 53780 AVENIDA CORTEZ LA QUINTA,CA 92253 Approved:7/20/2017 RGR 2 Subdivision:SANTA CARMELITA AT VALE LA QUINTA Block: 197 Lot: 23 Issued: UNIT 19 Lot Sq Ft:0 Building Sq Ft: 0 Zoning: Finaled: 12/28/2017 RGR ftsr 0) Valuation:$0.00 Occupancy Type: Construction Type: Expired: No. Buildings:0 No. Stories:0 No. Unites:0 Details: Applied to Approved ADDITIONAL SITES MIL ■ ; ILI - CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES DEPOSIT REFUNDED. 101-0000-22811 CLOSED. COUNCIL DEPOSIT MIRTA LERMA 8/13/2018 8/13/2018 APPROVED A FLAT FEE STRUCTURE FOR FIRE INSPECTION AUGUST 2017. CONDITIONS in CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET BILL TO J C FIRE PROTECTION 81705 DE ORO AVENUE INDIO CA 92201 JCFIREPROTECTION@V ERIZON.NET OWNER JOHNA BODGE 53600 AVENIDA LA QUINTA CA 0 MADERO Printed: Monday,January 30, 2023 11:05:34 AM 1 of 2 CRW.sysTEms Permit Details PERMIT NUMBER U �I P ow�� City of La Quinta FSS2017-0014 `y of TY# Ail FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT# CHECK# METHOD PAID BY CLTD BY FIRE SPRINKLER SYSTEMS RESIDENTIAL- 101-0000-22811 1 $614.00 $614.00 7/18/17 R26577 1232 CHECK J C FIRE PROTECTION SKH CUSTOM Total Paid for FIRE SPRINKLER SYSTEMS RESIDENTIAL- CUSTOM: $614.00 $614.00 TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 7/18/17 R26577 1232 CHECK J C FIRE PROTECTION SKH ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: $619.00 $619.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE FIRE FINAL** RGR APPROVED OVERHEAD ROUGH RGR 9/19/2017 9/19/2017 APPROVED PIPING PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS REMARKS NOTES DATE 1ST FIRE(2 WK) RONALD 7/18/2017 8/1/2017 7/20/2017 APPROVED GRIESINGER BOND INFORMATION ATTACHMENTS Printed: Monday,January 30, 2023 11:05:34 AM 2 of 2 CANWsysrEms _ �� I 1 ii O N N HARDENED HEX HEAD SELF HARDENED HEX HEAD SELF SPRINKLER SPACING v AREA 1 AREA 2 GENERAL FIRE SPRINKLER NOTES ( � � I THREADING SCREW THREADING SCREW MATERIALS AND INSTALLATION OF THIS ARE SPRINKLER ,_ MAXIMUM DISTANCE BETWEEN SPRINKLER IN ROOMS WITH ONE HEAD IS 16X16 - - --. CALCULATION DESIGN !INFORMATION CALCULATION DESIGN INFORMATION 1. ALL DESIGN, _ _ ® ® FEET (8 FEET OFF WALLS). / SYSTEM SHALL COMPLY WITH NFPA 13D AND LA QUINTA CITY FIRE CODE ol‘��>,>.�l` I � MAXIMUM DISTANCE BETWEEN SPRINKLERS IN ROOMS WITH MORE THAN ONE / B CALCULATION AREA#1 TOILET CALCULATION AREA#1 W.I.C. REQUIREMENTS. a HEAD IS 12x12 FEET (6 FEET OFF WALLS). ::: ::::ALLATED ::::: :: ATED 2. THE SCOPE OF WORK FOR THIS PROJECT IS THE INSTALLA11ON OF FIREa • IOBSTRUCTION SPRINKLERS SHALL BE LOCATED A MINIMUM OF 6 FROM A WALL (NFPA) Iy 16X16 D 12X12 SPRINKLERS AT NEW SINGLE FAMILY RESIDENCE (SEE PLANS). W v n I • \O�. DOMESTIC WATER ALLOWANCE - 5 GPM DOMESTIC WATER ALLOWANCE 5 GPM 3. ALL NEW OVERHEAD PIPING SHALL BE BLAZEMASTER CPVC SPRINKLER 1 w O w u o ' ' �' '� PIPE AND FITTINGS JOINED WITH MANUFACTURER PRESCRIBED CEMENTING - L1 bj DOUBLE FASTENER STRAP TYPE SINGLE FASTENER STRAP TYPE \ ., SYSTEM DEMAND SYSTEM DEMAND PROCESS. III a HANGER HANGER - D A �" F INSTALLATION NOTES / PSI AVAILABLE AT SOURCE 42.4 PSI AVAILABLE AT SOURCE 42.4 4. ALL MATERIAL USED IN THE INSTALLATION OF THIS FIRE SPRINKLERCD TYPICAL HANGER DETAILS \ SYSTEM SHALL BE NEW AND OF CURRENT ISSUE. ALL MATERIAL SHALL BE z z PSI REQUIRED AT SOURCE 34.5 PSI REQUIRED AT SOURCE 35.3 2 Ei ALL HANGERS SHALL BE PER NFPA 13D & THE 1. ALL CEILINGS THROUGHOUT RESIDENCE ARE HORIZONTAL , A > (D - 8 inches) + B APPROVED BY UNDERWRITERS LABORATORIES (U.L) AND BE IN CONFORMANCE I Ice cc -- - WITH THE MOST CURRENT ISSUE OF NFPA 13, 13D AND THE AUTHORITY Co CODE REQUIREMENTS OF THE LOCAL AUTHORITY. D< or = 30 inches GPM REQUIRED AT SOURCE 18.0 GPM REQUIRED AT SOURCE 21.0 O 2. ELEVATIONS AND DIMENSIONS SHOWN ON THESE DRAWINGS ARE NOMINAL HAVING JURISDICTION. a: . . > TABLE 4-5.2.2,1 MAXIMUM DISTANCE BETWEEN HANGERS(FT-IN.) FIELDACTUAL (4)MAY VARY AND SHALL BE MODIFIED AS REQUIRED FOR NFPAI3D PSI @ B.O.RISER 26.0 PSI @ B.O.RISER 16.1 5r. . ALL SYSTEM PIPING SHALL BE HYDROSTATICALLY TESTED AS REQUIRED rY BY AHJ. NOMINAL PIPE 3. PIPE LENGHTS SHOWN ARE CENTER TO CENTER. MAINTAIN 36" MINIMUM FROM THE LLJ o et SIZE (IN) to 3/4 1 1 1/4 1 1/2 2 2 1/2 CENTER OF CEILING FANS & LIGHT w W 6. ALL SPRINKLERS SHALL BE DESIGNED FOR USE IN RESIDENTIAL Ce Z CPVC 5-6 6-0 6-6 7-0 8-0 9-0 O4.THERS)INSULATION TO BE INSTALLED ABOVE ALL CPVC FIRE SPRINKLER PIPING (BY FIXTURES THAT ARE OBSTRUCTIONS OCCUPANCIES. V i TO SPRINKLER DISCHARGE. eL 8. ELEVATIONS AND DIMENSIONS SHOWN ON THESE DRAWINGS ARE NOMINAL Z v ACTUAL MEASUREMENTS MAY VARY AND SHALL BE MODIFIED AS REQUIRED a M M 1-- TABLE FOR FIELD CONDmONS. � Y MAXIMUM SUPPORT SPACING DISTANCE Cl_ 9. SPRINKLERS SHALL BE PERMITTED TO BE OMITTED IN SMALL CLOSETS END LINE SPRINKLER HEAD DROP ELBOW WHERE THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ. FT. AND THE (I) Y Y LEAST DIMENSION DOES NOT EXCEED 3 FEET, CARPORTS AND BREEZEWAYS > > PIPE SIZE SYSTEM PRESSURE -J < inches less than 100 psi more than 100 psi ix Y z z 3/4 9 6 13 CI W W 1 12 9 0.. ix W cn 11/4 16 12 Z Z Y_ Y_ 11/2-3 24 12 > > 3 3 w w Z Z TABLE 2 -- ---- ---------_--__-- __--_--- � 00 AREA 2 _�....w - .K MAXIMUM SUPPORT SPACING DISTANCE FIRE PROTECT ON SYMBOLS cn INLINE SPRINKLER HEAD DROP TEE /1 /i , , SYMBOL DESCRIPTION PIPE SIZE SYSTEM PRESSURE \ j `�. BEDROOM 2 i � ! � NEW FIRE SPRINKLER RISER W/ Inches less than 100 psi more than 100 psi _ P © I \ / � I SEDDOMESTIC SHUT OFF VALVE 3/4 4 3 1 F 1 5 4 /M Irvi u. � /~ �' "' CV N A - © NEW PENDENT SPRINKLER (SEE SPRINKLER LEGEND) Z Cr) 11/4 6 5 1. 6-6 -O 9-O 5-0I 5-0 i> NEW PENDENT SPRINKLER (SEE SPRINKLER LEGEND) O U 11/2-3 7 7 �- (B)/ r ~I Io r.-) U "oO o co I i S T EP P;ATHPC�.M' co z W rnZ u U I_ SUPPORT SPACING AT SPRINKLERS �- 1 ( --=- � IC�`- `dI ' �_ - N I P1 , �`� -4 NEW PIPING (CUT ON JOB) " a .� U LLI o SEE TABLE 1 SEE TABLE 2 • I ,- - �� a t 1, I -' - S. PIPE HANGER LOCATIONS cD w O Z ri-t: ,-; , \ 1- .` W 5-3 2 2-0 -- 0- w I,v/ ' , / ;21 f 71 XX HYDRAULIC CALCULATION NODE (REFERENCE POINT) LI E I KITCHEN ) 1 B.BP_.00 o LL. N UL LISTED PIPE CLAMP ! USE ONLY UL LISTED FASTENERS 11 - - o I FINISHED CEILING • o I r" I• -.- c 073 of 0 , 0 \i‘k„,N I _ i +, o _ 1� 3-3, LL Pur F ATI! fir 5 3 '' --2;g r , /1. i , ' , - IANNIIIP 9 JC FIRE PROTECTION I r� g i r3 „ t-9� 170 = 0 i " IE'-0" Gig_ MINIMUM DISTANCES FOR ORDINARY -- 1 •-= " 1i AND INTERMEDIATE TEMPERATURE ' = ° - - RESIDENTIAL SPRINKLERS N N W W M HYDRAULIC CALCULATION DATA =� ( ( I MINIMUM DISTANCE MINIMUM DISTANCE (� I FROM EDGE OF FROM EDGE OF 0 l ( 1_°,EriFCADM LL. �-I P/ r i \ 11 • © SOURCE TO SOURCE TO ' '�' P` 5-, 2 2-1-0' Gig HEAT SOURCE ORDINARY INTERMEDIATE �_ �53 2- - TEMPERATURE TEMPERATURE BASED ON WATER PRESSURE OF / tl I1 V 1 SPRINKLER SPRINKLER I I Cn <c' 42.4 SOURCE7CDP4 U __a ,,,,,, z INCHES INCHES CC U F-IV , i t__ ,,, c, ,1---11 rn / SIDE OF OPEN OR J RECESSED FIREPLACE i ( GPE T I �7C3}�1 o • 0 36 12 Y II 1- / . , /\, t--,- ---'.,,:- [ -4-' Z Li] I-I FRONT OF RECESSED 4 60 36 It--�1 / r FIREPLACE Q TWO HEAD CALCULATION: _ I I W 21.0 GPM @ 16.1 PSI - { D SIDE OF CEILING- ORill F--I _ze/ Al - 1• I. 1• 1, WALL-MOUNTED HOT 24 12 4p4@ BOTTOM OF RISER Q� -0 4-0 AIR DIFFUSERS , j ? 3 2- 1-3 FRONT OF w �l / CY WALL-MOUNTED HOT 36 18 Z j AIR DIFFUSERS Q OO 4 i GARAGE ONE HEAD CALCULATION: 1 1 GHI '- ,� Gigo Wr FI250XTU w 6 3 Cr) GPM @ 26.0 PSI @ BOTTOM OF RISER I LIGHT FIXTURE E 250 W - 499 W 12 6 Z +, o KITCHEN RANGE 18 9 0 a. II ii SPARE HEAD BOX WILL BE PROVIDED WITH AT 1. 1'\rt FIRE SPRINKLER -o / 4-0 PIPING PLAN LEAST ONE (1) SPARE SPRINKLER HEAD OF EACH O TYPE, SIDE AND ORIFICE INSTALLED IN TIME SYSTEM. /� 1 " SPRINKLER RISER/DOMESTIC SHUT OFF -' 4- I . \ 1. \ z z TO �, DOM . 15 3 5-°.� E) OBSERVED PRESSURE 07-12-17 r.1 - I- SYSTEM 1 1 /4 U .G. PVC WATER SUPPLY 38 FT. FROM B METER TO RISER ♦ 14 ACTUAL STATIC PSI : 47.2 in 0 0 CPVCfi B I A ADJUSTED PSI: 42.4 t RSPESIDENTIALRINKLERRISER FIRE fb 3/4'' WATER METER a > U ( 1\/ 1 U .G. COPPER WATER SUPPLY 10 FT. FROM N2 i//t; AHJ USE ONLY /RPSI GAUGE D ® REVISIONS I PSI RELIEF SOURCE TO METER VALVE SET AT r 1i A 125 PSI MIN. & -----"�■� ° I 150 PSI MAX. II I 11 I D A �s. I_ - _ J RUBBER FACED SWING f...))-4. 1 CHECK VALVE A APPROVAL // Riverside County Fire Department AREA CALCULATIONS MAIN DRAIN '"'"►, DOMESTIC SHUT OFF 0, ce of 'n Ire Marshal LIVABLE 1,781 - a u VALVE (IF REVD) LIGHTS, FANS AND DIFFUSERS By r ' GARAGE 437 46 ona nes+nger , . �i► TO DOMESTIC SHALL BE COORDINATED AROUND Theapp p ificationsdoesno royal of tans and spec TOTAL SYSTEM AREA 2,218 Q stall the violation,du rements osTitle 24 orlany >- ins ection purposes until SPRINKLER HEADS TO AVOID LocalOrdnances. eq PRESSURE AT SITE NI J local Ordinances.Construction shall remain 7-12-17 a 0 No_ COMBINED SHUT OFF � roved by Flre�pepartmenG r ` v, VALVE SPRINKLERS SHALL BE LOCATED A MINIMUM OF 6" FROM A WALL OBSTRUCTIONS AND HEAT SOURCE 47.2 PSI6 ak 1.25" PVC ERE SPRIN 'KLER PIPING PLAN DESIGNER CM cir) ern, SUPPLY FROM �� SCALE: 3/16 = 1-o DISTANCES IN ACCORDANCE WITH SCALE 3/16 = 1-0 METER (BY NFPA RECOMMENDATIONS OTHERS) VI"). - CHECK BY NCS (TYPICAL) FILE NUMBER 17.193 APPROVAL LA QUINTA 1 " RISER DETAIL DATE 7-13-17 N.T.S. DRAWING NO. FP1 tc.re? 4116 Sheet 1 of 1 Sheets VI'w l' "w • Lit\ 1,.,. , -.- ---- *ATE)? Residential'Conr ection Charge Estimate Date: , t. December 1,-2016 , ! Customer Name: ;Ronald'Stackdai ~ -•~--M---- -- __... _ _.. . Phone No.; 578-1077 (760): Parcel No.,,_ ';774-142 042 ''� t �_c Geo. .__ , 06-06-1213 Address.. 5-3780,Avenida Cor ez,'La Qulnta� _1 LID: 688770 Block No Lot No. ` - 23 (Size of Lot: 1 .4,792 I sue. ft. ' p L] Tract NoS❑anta Carmelita Type of Service: R_1: Duplex:P Triplex: Apts: tom• SWSC:}�$ ,....--.---..---7� cres•�».-..--..�_.� SWS ..._ . _r .p _ � , A 0.1:1' c:x$12,218.00 /acre WSBFC: .$ r. = SCC: $ -,,,G -• ' ` Treatment: $2,436/edu $2,415/edu ; / Collection: Meter =, - �` ' _� •�..�,:_.--�..,.. '1 $ •y ..�-, 4.O0A0 Meter Size inch ' Meter surcharge p $ _ .. #: 2:41.9:00 Service Size 1 Inc!,' { Service'I $_ ' • Meter&Service:?$ - ,. f Abandon: Backflow:r$: - Other:: '$ - -'�. `] Per account 266619-688770 a 3/4"meter exists.SCC was paid Sewer Lateral:'`$.: _ on 4/7/98,MCR#67279 PZ 16-7577 Total: $ 2,879.00 tTechiicn:Ruben'IVlontielcy,' ' . ' _ Fees Approved by: .i�� r 1°1- �pate:_ 11--. _ a I Information Supplied By Customer , CVWD System Data Domestic Water Demand* _ .... Service Connection** Max. Flow=, • ' `20 gprn. , Max. Flow*= �^ 26 gpm- ' . . Min. Pressure 20' Inlet Pressure 1 =1 - . . 4'7,2 - Sipsi Fire Sprinkler Demand* _ Outlet Pressure=( 24.6 psi Max. Flow= =26 - ' g • Min. Pressure=l ,20 . Meter Size. .p5 U _ El _ . 1• inch System Type: Service Size=j 1 inch Multi Stand Alone 1 Prior to Pressure Regulating Valve **For Calculation Purposes-Service Connection Includes: *CVWD USES WORST CASE CONDITION Service Connection Pipe=50',Meter Stop,Meter,Check Valve&Shut Off Valve Calculations: PZ=Middl'I R-7 Res.#= 6631 Res./Ht= 17' /Q�-*ITS., 6., HGL= 35ct' Property Elev.= 7S7' �7 y' .. „, Ey.,:,- i fh( . j , ;- . ,J CI 5 'b *Static Water Pressure 47.2 PSI },lE�� ' PSn.�.%a=,;,� I •' *Domestic Water Demand Residual Pressure 24.5 PSI a -cer.�s Fd: a "Requires a tower Pressure Water Agreer^nent 4\ Al . \�` Apppi+��d : q2/f Date: 544, The meter sizing is for plan check purposes ordy.The ultimate res onsibil p ity�resides with the Engineer-of-Record for the project. *#**�:,* cvwd-950 -This is just a QUOTE,all fees are subject to Change********* (Rev.9/15) I, •. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 . DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\\REA11HD.SDF JOB TITLE: AREA 1 1HD (16x16) (13 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) S (N/A) 42.4 (N/A) 42.4 18.0 34.5 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 18.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 13.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) P1 10.0 - - - - 19.2 - - - P2 10.0 - - - - 19.2 - - - P3 10.0 K= 3.00 18.8 13.0 1 10.5 - - - - 18.9 - - - 2 10.5 - - - - 18.9 - - - 3 10.5 - - - - 18.7 - - - A 10.5 - - - - 18.9 - - - B 10.5 - - - - 18.9 - - -_ C 10.5 - - - - 19.2 - - - D 10.5 - - - - 19.6 - E 15.5 - - - - 18.2 - - - TOR 10.5 - - - - 20.8 - - BOR 1.0 - - - - 26.0 - - - DOM 0.5 HOSE STREAM 26.6 5.0 M1 0.0 - - - - 27.6 - - - M2 0.0 - - - - 33.6 - - - S 0.0 SOURCE 34.5 18.0 APPROVAL Riverside County Fire Department By 0 ce of th Fir Marshal ona d Griesinger The approval of plans and specifications does not permit the violation,deletion,omission or faulty installation of any requirements of Tide 24 or any Local Ordinances.Construction shall remain accessible and exposed for Inspection purposes until . approved by the Fire Department. • y ;: u SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDF JOB TITLE: AREA 1 1HD (16x16) (13 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 0.50 PF 0.0 P1 10.0 0.0 19.2 0.0 0.0 150 FTG E PE -0.2 1 10.5 0.0 18.9 0.0 0.000 TL 3.00 PV Pipe: 2 0.0 1.101 PL 0.50 PF 0.0 P2 10.0 0.0 19.2 0.0 0.0 150 FTG E PE -0.2 2 10.5 0.0 18.9 0.0 0.000 TL 3.00 PV Pipe: 3 -13.0 1.101 •PL 0.50 PF 0.1 P3 10.0 3.0 18.8 13.0 4.4 150 FTG E PE -0.2. 3 10.5 0.0 18.7 0.0 0.031 TL 3.00 PV Pipe: 4 0.0 1.101 PL 4.25 PF 0.0 1 10.5 0.0 18.9 0.0 0.0 150 FTG T PE 0.0 A 10.5 0.0 18.9 0.0 0.000 TL 10.25 PV Pipe: 5 0.0 1.101 PL 3.75 PF 0.0 2 10.5 0.0 18.9 0.0 0.0 150 FTG T PE 0.0 A 10.5 0.0 18.9 0.0 0.000 TL 9.75 PV Pipe: 6 -13.0 1.101 PL 2.00 PF 0.3 3 10.5 0.0 18.7 0.0 4.4 150 FTG TR PE 0.0 B 10.5 0.0 18.9 0.0 0.031 TL 9.70 PV Pipe: 7 0.0 1.101 PL 6.50 PF 0.0 A 10.5 0.0 18.9 0.0 0.0 150 FTG TR PE 0.0 B 10.5 0.0 18.9 0.0 0.000 TL 14.20 PV Pipe: 7A -6.5 1.101 PL 18.00 PF 0.2 B 10.5 0.0 18.9 0.0 2.2 150 FTG T2R PE 0.0 C 10.5 0.0 19.2 0.0 0.008 TL 27.40 PV Pipe: 8 -6.5 1.101 PL 39.25 PF 0.4 C 10.5 0.0 19.2 0.0 2.2 150 FTG T4R PE 0.0 D 10.5 0.0 19.6 0.0 0.008 TL 52.05 PV Pipe: 9 -6.5 1.101 PL 57.25 PF 0.7 B 10.5 0.0 18.9 0.0 2.2 150 FTG 2T5R PE 0.0 D 10.5 0.0 19.6 0.0 0.009 TL 77.75 PV Pipe: 10 -13.0 1.101 PL 17.25 PF 0.8 D 10.5 0.0 19.6 0.0 4.4 150 FTG TR PE -2.2 E 15.5 0.0 18.2 0.0 0.031 TL 24.95 PV Pipe: 22 -13.0 1.101 PL 10.25 PF 0.4 E 15.5 0.0 18.2 0.0 4.4 150 FTG E PE 2.2 TOR 10.5 0.0 20.8 0.0 0.031 TL 12.75 PV is SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/14/2017IDA CORTEZ RESIDENCE LA QUINTA - CA - JCP\AREA 1 1HD.SDF JOB TITLE: AREA 1 1HD (16x16) (13 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 23 -13.0 1.101 PL 9.50 PF 1.1 TOR 10.5 0.0 20.8 . 0.0 4.4 150 FTG 27.0 PE 4.1 BOR 1.0 0.0 26.0 0.0 0.031 TL 36.50 PV Pipe: 26 -13.0 1.101 PL 2.00 PF 0.4 BOR 1.0 0.0 26.0 0.0 4.4 150 FTG 2ET PE 0.2 DOM 0.5 H.S. 26.6 . 5.0 0.031 TL 13.00 PV Pipe: 27 -18.0 1.394 PL 38.00 PF 0.7 DOM 0.5 H.S. 26.6 5.0 3.8 150 FTG E PE 0.2 M1 0.0 0.0 27.6 0.0 0.018 TL 41.80 PV Pipe: 28 FIXED PRESSURE LOSS DEVICE M2 0.0 0.0 33.6 0.0 6.0 psi, 18.0 gpm M1 0.0 0.0 27.6 0.0 Pipe: 29 -18.0 1.055 PL 10.00 PF 0.9 M2 0.0 0.0 33.6 0.0 6.6 150 FTG .3.0 PE 0.0 S 0.0 SRCE 34.5 (N/A) 0.069 TL 13.00 PV NOTES (HASS) : (1) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 50081438 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.054 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 6.6 ft/sec at pipe 29. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node S under full flow conditions is 42.40 psi with a flow of 20.05 gpm. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/14/2017IDA CORTEZ.RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDF JOB TITLE: AREA 1 1HD (16x16) (13 GPM) PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v A1mChk DPVly NPTee 1.055 2.06 5.14 2.06 5.14 6.17 1.03 10.28 10.28 5.14 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 El Tee RunT Kplg ChkVly Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 1.394 1.80 3.80 7.30 2.30 1.00 11.00 0.80 LI _1 WATER SUPPLY ANALYSIS CO y Fixed Source. Pressure: 42 . 40 psi H 1-1 60 . 0 y r 1 G-Available pressureili • a 42.40 psi @ 18.0 gpm > N ,'L7 O 2 C7 1-- VIRequired pressure 50 . 0 39.48 psi @ 18.0 gpm 1-1 i- d m n G c x ro A 1 61 N Z U A. source supply curve r G 40 . 0 B. System Demand Curve °� m x E I-1 2 m K w z cn P alln IA 0 t m • R 3 1 3 E 30 . 0 — m > o S z ,o > S c c . 1-1 r U z H H O R > E 20. 0 1 z n r > K ( , I ---1 p o s • to i 10 . 0 >i . . x I-i I-' m 0 . 0 • w cn 0 (D M • in -14 .7 6010 9)0 1)00 1)00 18100 2)00 24100 2)00 313100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 1 1HD.SDF JOB TITLE: AREA 1 1HD (16x16) (13 GPM) WATER SUPPLY CURVE 48+ 44+ 0\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 40+ 36+ X P 32+ R I E I S 1 S 28+ U I R I E I 24+ ( I P S I I 20+ I 16+ 12+ 8+ LEGEND I X = Required Water Supply I 34.48 psi @ 18.0 gpm 4+ I 0 = Available Water Supply 42.40 psi @ 18.0 gpm 0++-+---+----+ + + + + + + 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) v • SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 ' DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA_2_J2HD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) - S (N/A) 42.4 (N/A) 42.4 21.0 25.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 21.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 16.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) P1 10.0 K= 3.00 7.1 8.0 P2 10.0 K= 3.00 7.1 8.0 P3 10.0 - - - - 7.9 - - - 1 10.5 - - - - 6.9 - - - 2 10.5 - - - - 6.9 - - - 3 10.5 - - - - 7.7 - - - A 10.5 - - - - 7.1 - - - B 10.5 - - - - 7.7 - - - C 10.5 - - - - .8.0 - - - D 10.5 - - - - 8.7 - - - E 15.5 - - - - 7.6 - - - TOR 10.5 - - - - 10.4 - - - BOR 1.0 - - - - 16.1 - - - DOM 0.5 HOSE STREAM 16.9 5.0 M1 0.0 - - - - 18.1 - - - M2 0.0 - - - - 24.1 - - - S 0.0 SOURCE 25.3 21.0 U • SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -8.0 1.101 PL 0.50 PF 0.0 P1 10.0 3.0 7.1 8.0 2.7 150 FTG E PE -0.2 1 10.5 0.0 6.9 0.0 0.012 TL 3.00 PV Pipe: 2 -8.0 1.101 PL 0.50 PF 0.0 P2 10.0 3.0 7.1 8.0 2.7 150 FTG E PE -0.2 2 10.5 0.0 6.9 0.0 0.012 TL 3.00 PV Pipe: 3 0.0 1.101 PL 0.50 PF 0.0 P3 10.0 0.0 7.9 0.0 0.0 150 FTG E PE -0.2 3 10.5 0.0 7.7 0.0 0.000 TL 3.00 PV Pipe: 4 -8.0 1.101 PL 4.25 PF 0.1 1 10.5 0.0 6.9 0.0 2.7 150 FTG T PE 0.0 A 10.5 0.0 7.1 0.0 0.012 TL 10.25 PV Pipe: 5 -8.0 1.101 PL 3.75 PF 0.1 2 10.5 0.0 6.9 0.0 2.7 150 FTG T PE 0.0 A 10.5 0.0 7.1 0.0 0.012 TL 9.75 PV Pipe: 6 0.0 1.101 PL 2.00 PF 0.0 3 10.5 0.0 7.7 0.0 0.0 150 FTG TR PE 0.0 B 10.5 0.0 7.7 0.0 0.000 TL 9.70 PV Pipe: 7 -16.0 1.101 PL 6.50 PF 0.6 A 10.5 0.0 7.1 0.0 5.4 150 FTG TR PE 0.0 B 10.5 0.0 7.7 0.0 0.045 TL 14.20 PV Pipe: 7A -8.0 1.101 PL 18.00 PF 0.3 B 10.5 0.0 7.7 0.0 2.7 150 FTG T2R PE 0.0 C 10.5 0.0 8.0 0.0 0.012 TL 27.40 PV Pipe: 8 -8.0 1.101 PL 39.25 PF 0.6 C 10.5 0.0 8.0 0.0 2.7 150 FTG T4R PE 0.0 D 10.5 0.0 8.7 0.0 0.012 TL 52.05 PV Pipe: 9 -8.0 1.101 PL 57.25 PF 1.0 B 10.5 0.0 7.7 0.0 2.7 150 FTG 2T5R PE 0.0 D 10.5 0.0 8.7 0.0 0.013 TL 77.75 PV Pipe: 10 -16.0 1.101 PL 17.25 PF 1.1 D 10.5 0.0 8.7 0.0 5.4 150 FTG TR PE -2.2 E 15.5 0.0 7.6 0.0 0.045 TL 24.95 PV Pipe: 22 -16.0 1.101 PL 10.25 PF 0.6 E 15.5 0.0 7.6 0.0 5.4 150 FTG E PE 2.2 TOR 10.5 0.0 10.4 0.0 0.045 TL 12.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 23 -16.0 1.101 PL 9.50 PF 1.6 TOR 10.5 0.0 10.4 0.0 5.4 150 FTG 27.0 PE 4.1 BOR 1.0 0.0 16.1 0.0 0.045 TL 36.50 PV Pipe: 26 -16.0 1.101 PL 2.00 PF 0.6 BOR 1.0 0.0 16.1 0.0 5.4 150 FTG 2ET PE 0.2 DOM 0.5 H.S. 16.9 5.0 0.045 TL 13.00 PV Pipe: 27 -21.0 1.394 PL 38.00 PF 1.0 DOM 0.5 H.S. 16.9 5.0 4.4 150 FTG E PE 0.2 M1 0.0 0.0 18.1 0.0 0.024 TL 41.80 PV Pipe: 28 FIXED PRESSURE LOSS DEVICE M2 0.0 0.0 24.1 0.0 6.0 psi, 21.0 gpm M1 0.0 0.0 18.1 0.0 Pipe: 29 -21.0 1.055 PL 10.00 PF 1.2 M2 0.0 0.0 24.1 0.0 7.7 150 FTG 3.0 PE 0.0 S 0.0 SRCE 25.3 (N/A) 0.092 TL 13.00 PV NOTES (HASS) : (1) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 50081438 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.087 gpm. (3) Total pressure at each node is used in balancing the system. • Maximum water velocity is 7.7 ft/sec at pipe 29. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node S under full flow conditions is 42.40 psi with a flow of 29.01 gpm. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDF JOB TITLE: AREA 2. 2HD (12x12) (8 GPM) PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyV1v GatVly AlmChk DPVly NPTee 1.055 2.06 5.14 2.06 5.'14 6.17 1.03 10.28 10.28 5.14 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 El Tee RunT Kplg ChkVly Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 1.394 1.80 3.80 7.30 2.30 1.00 11.00 0.80 • • • • • • WATER SUPPLY ANALYSIS w y Fixed Source Pressure: 42 . 40 psi y . H 60. 0 y r II . a1FF • � ilable pressure 42.40 psi @ 21.0 gpm > N 7y o 11 1-,2 Required pressure > 50. 0 25.34 psi @ 21.0 gpm n> >10 N xc-) 0 o cn G m ro -- H 7zi A 1 N I--' C+7 H N z U x A. source suppl7 Curve 7y G 40 . 0 B. System Demand Curve N.) m m. E b-I -- o cn co m k z cn P ro m m R x I x E 30. 0 r K > o S S 2 7y I b r U _ z H H 0 R E 20 . 0 I z O r > K Cl) ( _ I H . ( p g ro i 10. 0 7y ' N • T N x o 'c7 0. 0 •nw c o (D • cn • . -14 . 7 6)0 9)0 1)00 J00 1)00 21I00 24100 2/00 3(T00 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/14/2017IDA CORTEZ RESIDENCE - LA QUINTA - CA - JCP\AREA 2 2HD.SDF JOB TITLE: AREA 2 2HD (12x12) (8 GPM) WATER SUPPLY CURVE 48+ 44+ 0\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 40+ 36+ P 32+ R I E I S I S 28+ U I R I E X 24+ ( P I S I 120+ I 16+ • 12+ 8+ LEGEND 1 1 X = Required Water Supply I 25.34 psi @ 21.0 gpm 4+ I 0 = Available Water Supply " 42.40 psi @ 21.0 gpm I " 0++-+---+----+ + + + + + + 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) r c tL,CD Fire & Building Products let rapid responseM HOME FIRE SPRINKLER SYSTEM Technical Services:Tel: (800)381-9312/Fax: (800) 791-5500 BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data , Tyco Fire& Building Products (TFBP) Sizes , • BlazeMaster CPVC Pipe and Fittings 3/4"to 3" are designed exclusively for use in wet Maximum Working Pressure •� pipe automatic fire sprinkler systems. 175 psi They are made from a specially devel- oped thermoplastic compound corn- Approvals r ' k. posed of post chlorinated polyvinyl UL, FM, CUL, NSF, Dade County, o ,` < chloride (CPVC) resin and state of the LPCB, MEA, and the City of Los Ange- art additives. TFBP BlazeM aster les. (Refer to IH-1900, Rev. 0, Janu CPVC products are easier to install ary 2005 "Installation Instruction & than traditional steel pipe systems, Technical Handbook" for exact list- and at the same time, provide superior ing/approval information.) heat resistance and strength as com- Manufacture Source pared to traditional CPVC and PVC U.S.A. piping materials used in the plumbing trade. Various adapters are available Material to connect CPVC pipe to metallic pip- . Pipe: ASTM F442, SDR 13.5 ing. All female pipe thread adapters have brass inserts for durability. • Fittings: ASTM F438 (Sch. 40) and Grooved adapters connect directly to ASTM F439(Sch.80), ASTM F1970 grooved end valves and metallic pipe, Color with flexible grooved end couplings. Orange WARNING Tyco Fire& Building Products(TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMaster°is a registered trademark of Noveon lP Holding Corp. Page 1 of 6 JANUARY, 2006 TFP1915 • Page 2 of 6 TFP1915 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT.OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs./ft. lbs./ft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2" 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1 — PIPE DIMENSIONS Installation Care and Tyco Fire and Building Products Maintenance (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- The owner is responsible for the fin- ance with IH-1900, Rev. 0, January spection, testing, and maintenance of 2005"Installation Instruction&Techni- their fire protection system and de- cal Handbook". vices in compliance with this docu- ment, as well as with the applicable • standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national • codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls,permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. ++c i TFP1915 Page 3 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE SCHD. (T/O) (lb.) TEE 80000 3/4" 5/8" 40 0.11 T/O 80001 1" 11/16" 40 0.19 %„�_-. 80002 1-1/4" 7/8" 40 0.26 •iiM 80003 1-1/2" 1-1/16" 80 0.51 MEM. 80004 2" 1-3/8" 80 0.90 T/O ■■ T/O 80005 2-1/2" . 1-9/16" 80 1.59 80006 3" 1-13/16" 80 2.41 XxYxZ X Y Z 80132 3/4"x 3/4"x 1" 3/4" 3/4" 5/8" 40 0.14 80133 1"x 3/4"x 3/4" 9/16" 9/16" 3/4" 40 0.14 80134 1"x 3/4"x 1" 3/4" 11/16" 3/4" 40 0.17 , 80260 1"x 1"x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4"x 1"x 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4"x 1"x 1" 3/4" 3/4" 15/16" 40 0.22 ' 80137 1-1/4"x 1"x 1-1/4" 15/16" • 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4"x 1-1/4"x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4"x 1-1/4"x 1" 3/4" 3/4" 7/8" 40 0.26 Z 80138 1-1/4"x 1-1/4"x 1-1/2" 1" 1" 1" 80 0.43 40„/ T/O •80140 1-1/2"x 1-1/4"x 3/4" 9/16" 9/16" 1" 80 0.36 .� �� r 80141 1-1/2"x 1-1/4"x 1" 9/16" 9/16" 1-1/16" 80 0.38 MEI 80263 1-1/2"x 1-1/2"x 3/4" 9/16" 9/16" 1" 80 0.36 X ■111-Y 80264 1-1/2"x 1-1/2"x 1" 9/16" 9/16" 1-1/16" 80 0.38 �nr'-� 80275 1-1/2"x 1-1/2"x 1-1/4" 7/8" 7/8" 1" 80 0.45 T/O •• T/O 80265 2"x 2"x 3/4" 3/4" 3/4" 1-3/8" 80 0.61 80266 2"x 2"x 1" 7/8" 7/8" 1-3/8" 80 0.66 80274 2"x 2"x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 • 0.74 • 80267 2"x 2"x 1-1/2" 1-1/8" • 1-1/8" 1-3/8" 80 0.78 80271 2-1/2"x 2-1/2"x 1" 1-9/16" 1-9/16" 1-9/16" 80 1.43 80272 2-1/2"x 2-1/2"x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2"x 2-1/2"x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 • 2-1/2"x 2-1/2"x 2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3"x 3"x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3"x 3"x 2" 1-13/16" 1-13/16" 1-3/4" r 80 • 2.25 80269 3"x 3"x 2-1/2" 1-13/16" 1-13/16" 1-13/16". 80 2.44 CROSS&REDUCING CROSS 80009 3/4" 9/16" 40 0.13 80010 1" 11/16" 40 0.23 J�� -- T!O 80011 1-1/4" 15/16" f 40 0.34 �iiM■ 80012 1-1/2" 1-1/16" 80 0.67 . MEM. 80013 2" 1-5/16" .80 1.00 II„I>( 80014 2-1/2" 1-9/16" 80 1.91 II T!O 80008 3" 1-13/16" 80 2.89 T/O ■■ T/O 80015 1"x 1"x 3/4"x 3/4" 7/8" 40 0.28 80025 3/4" 5/8" 40 0.09 . 90°ELBOW&REDUCING ELBOW 80026 1" 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 ;NM T/O 80029 2" 1-5/16" 80 0.79 j 80030 2-1/2" 1-9/16" 80 1.14 MOM 80031 3" . 1-13/16" 80 . 1.82 • � Y X x Y X Y T/O 80032 1"x 3/4" 11/16" 13/16" 40 0.16 FIGURE 2- FITTING DIMENSIONS(Part 1 of 4) Page 4 of 6 TFP1915 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE • (T/O) SCHD. (lb.) 45°ELBOW 80050 3/4" 3/8" • 40 0.08 T/O 80051 1" 3/8" 40 0.11 ��, 80052 1-1/4" • 3/4" 40 0.20 , 80053 1-1/2" 1/2" 80 0.31 T/O �No AIM 80054 2" 3/4" 80 0.56 • �'��� 80055 2-1/2" 13/16" 80 0.89 80056 3" 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING& 80076 1" 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 ' 'e'- 80078 1-1/2" • 3/16" 80 0.25 80079 2" 3/16" 80 0.38 r, , 80080 2-1/2" 1/4" 80 0.67 -T/O 80081 3" 3/16" 80 0.91 -I80220 1"x 3/4" 1/8" 40 0.08 80200 1"x 3/4" 7/16" 40 0.04 80201 1-1/4"x 3/4" 1/2" 40 0.11 80202 1-1/4"x 1" 5/16" 40 0.12 80203 1-1/2"x 3/4" 5/8" 80 0.16 80204 1-1/2"x 1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2"x 1-1/4" 3/8" 80 0.17 80206 2"x 3/4" 13/16" 80 0.27 i 80207 2"x 1" • 11/16" 80 0.26 80208 2"x 1-1/4" 9/16" 80 0.24 -' 80209 2"x 1-1/2" 7/16" 80 0.19 --I T/O 80215 2-1/2"x 1" 15/16" 80 0.42 80214 2-1/2"x 1-1/4" 13/16" 80 0.45 80213 . 2-1/2"x 1-1/2" 11/16" 80 0.46 80211 2-1/2"x 2" 5/8" 80 0.29 80210 3"x 2" 3/4" 80 0.72 80212 3"x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 1" 3/8" . 40 0.06 4-4 '4 80102 1-1/4" 7/16" 40 0.10 80103 1-1/2" • 11/16" 80 0.20 . ,1)1 80104 2" 5/8" 80 0.31 T/O-I 80105 2-1/2" 7/8" 80 0.58 80106 3" 1" 80 0.88 GROOVED T/O PIPE O.D. COUPLING ADAPTER 80160 1-1/4"x 1-1/4"Groove 2-5/16" 1-1/4"(1.660") 40 0.78 ...max• I 80161 1-1/2"x 1-1/2"Groove 2-5/16" 1-1/2"(1.900") 80 0.95 PIPE 80162 2"x 2"Groove 2-5/16" 2"(2.375") 80 1.42 O.D. sir-. x 80163 2-1/2"x 2-1/2"Groove 2-5/16" 2-1/2"(2.875") 80 2.28 80164 3"x 3"Groove 2-1/4" 3"(3.500") 80 3.00 T/O--I 80169 2-1/2"x 76,1 mm Groove ` 2-5/16" 76,1 mm(3.000") 80 2.28 • FIGURE 2 - FITTING DIMENSIONS(Part 2 of 4) 1 TFP1915 Page 5 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (I/O) SCHD. (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4"x 1/2"NPT 7/16" 80 0.20 80176E 1"x 1/2"NPT 7/16" 80 0.22 80175WL 3/4"x 1/2"NPT 7/16" 40 • 0.16 ,, 80179 1"x 3/4"NPT 13/16" 40 0.43 T/O SPRINKLER HEAD ADAPTER I 80175W 3/4"x 1/2"NPT 1/2" 40 0.19 80176W 1"x 1/2"NPT 1/2" 40 0.18 — T/O SPRINKLER HEAD ' ADAPTER(SPIGOT) _ 80177L 3/4"x 1/2"NPT 1/2" 40 0.16 IIIII UUU 80178 1"x 1/2"NPT 9/16" 40 0.2.0 �4ii=. 80180 1"x 3/4"NPT 7/8" 40 0.40 --I T/O • FEMALE ADAPTER • \\\\` 80142 3/4"x 3/4"NPT 13/16" 40 0.41 80145 1'x 1"NPT 7/8" 40 0.63 1.03 80146 1-1/4"x 1-1/4"NPT 1-1/8" 40 \\\\ 80147 .1-1/2"x 1-1/2"NPT 1-3/8" 80 1.42 "7 80148 2"x 2"NPT 1-11/16" 80 2.66 —T/O MALE ADAPTER • ,iiii 80157 3/4"x 3/4"NPT 1-5/16" 40 0.33 80158 1'x 1"NPT • 1-3/8" 40 0.56 . -- T/O—1 XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4"x 3/4"x 1/2"NPT 9/16" 9/16" 1" 40 0.22 Z 80251 1"x 1"x 1/2"NPT 11/16" 11/16" 1-3/16" 40 0.29 A'F..m T/O 80249 1"x 1"x 1"NPT 15/16" . 15/16" 1-9/16" 40 0.73 80256 1-1/4"x 1"x 1/2"NPT 7/16" 9/16" 1-5/16" 40 0.30 =`+M 80252 1-1/4"x 1-1/4"x 1/2"NPT 7/16" 7/16" 1-5/16" 40 0.31 X -MEIN Y 80257 1-1/2"x 1-1/4"x 1/2"NPT 1/2" 11/16" 1-7/16" 80 0.43 or +��� 80254 1-1/2"x 1-1/2"x 1/2"NPT 1/2" 1/2" _ 1-7/16" 80 0.46 T/O •• T/O 80258 2"x 1-1/2"x 1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x 2"x 1/2"NPT 1/2" 1/2" . 1-11/16" 80 0.62 • FIGURE 2— FITTING DIMENSIONS(Part 3 of 4) Page 6 of 6 TFP1915 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (T/O) SCHD. (lb.) BACK-TO-BACK TEE X x Y x Z X Y,Z X ✓ r • , T/O e e I Y 80459 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.48 Z I 80460 1"x 1/2"NPT x 1/2"NPT 5/8" , 1-3/16" 40 0.46 T/O T/O BACK-TO-BACK CROSS X x Y x Z x W X,Y - Z,W X T/O Z: "f-- IIIITI`�'i_1111 ��171a ��1 w 80462 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-3/16" 40 0.46 _--� f'>-. 80463 1"x 1"x 1/2"NPT x 1/2"NPT 5/8" 1-5/16" 40 0.47 T/O i111 L� T/O T/O • • SPRINKLER HEAD X x Y X Y - ADAPTER 90°ELBOW Y ` `I T/O It ....73... 80199 3/4"x 1!2"NPT 9/16" 1" 40 0.20 080198 1"x 1/2"NPT 3/4" 1-1/4" 40 0.26 •fi " 3/4" " 1-7/16" 40 ' 0.26 • r X 80196 1 x NPT 1-1/16 T/O FIGURE 2— FITTING DIMENSIONS(Part 4 of 4) . • Limited by TFBP to be defective shall be either of merchantability and fitness for a par- repaired or replaced, at TFBP's sole ticular purpose. Wa rra n t y option. TFBP neither assumes, nor This limited warranty sets forth the ex- clusive remedy for claims based on any other obligation in connection with failure of or defect in products, materi- Products manufactured by Tyco Fire& the sale of products or parts of prod- als or components, whether the claim Building Products (TFBP) are war- ucts.TFBP shall not be responsible for ranted solely to the original Buyer for sprinkler system design errors or inac- is made in contract, tort, strict liability or any other legal theory. ten(10)years against defects in mate- curate or incomplete information sup rial and workmanship when paid for plied by Buyer or Buyer's repre- This warranty will apply to the full ex- and properly installed and maintained sentatives. tent permitted by law.The invalidity, in under normal use and service. This whole or part, of any portion of this warranty will expire ten (10) years In no event shall TFBP be liable, in warranty will not affect the remainder. from date of shipment by TFBP. No contract, tort, strict liability or under warranty is given for products or com any other legal theory, for incidental, ponents manufactured by companies indirect,special or consequential dam not affiliated by ownership with TFBP ages, including but not limited to labor or for products and components which charges, regardless of whether TFBP have been subject to misuse,improper was informed about the possibility of installation, corrosion, or which have such damages, and in no event shall not been installed, maintained, modi TFBP's liability exceed an amount lied or repaired in accordance with ap- equal to the sales price. plicable Standards of the National Fire The foregoing warranty is made in lieu • • Protection Association, and/or the of any and all other warranties. ex- standards of any other Authorities press or implied. including warranties Having Jurisdiction. Materials found TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Page 1 of 5 NIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK470 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom®Residential Pendent Sprinkler VK470 is a thermosensitive, glass-bulb residen- tial sprinkler available in several different finishes and temperature ratings to meet varying de- sign requirements.The Electroless Nickel PTFE (ENT) coating has been investigated for instal- lation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated 1r,, in the Approval Chart. The sprinkler orifice design, with a K-Factor of 3.0 (43.2 metric*), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS „xmoriZ' Ous UL Listed (C-UL-US-EU): Category VKKW EU Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. \`‘.. 3. TECHNICAL DATA Specifications: Avaiilable since 2012. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Viking Technical Data may be found on Thread size: 1/2" (15 mm) NPT The Viking Corporation's Web site at Nominal K-Factor: 3.0 U.S. (43.2 metric*) http://www.vikinggroupinc.com. * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, The Web site may include a more recent divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) edition of this Technical Data Page. Overall Length: 2-1/4" (58 mm) Material Standards: Frame Casting: QM Brass Deflector: Phosphor Bronze UNS-051000 or Brass UNS-C23000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For ENT coated sprinklers: Belleville spring - Exposed. Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 17147 Order Sprinkler VK470 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome= F, White Polyester= M-/W, Black Polyester= M-/B, and ENT=JN Temperature Suffix: 155°F (68 °C) = B, 175 °F (79 °C) = D For example, sprinkler VK470 with a Brass finish and a 155 °F (68 °C)temperature rating = Part No. 17147AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for Recessed Sprinklers: Part No. 16036W/B** (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010.) **A 1/2"ratchet is required(not available from Viking). ***Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) Form No. F_061011 Rev 14.1 (Added EU Listing) , - , - - • - Page 2 of 5 • ® FREEDOMS RESIDENTIAL NTECHNICAL DATA - ' PENDENT SPRINKLER ... r . 4 VK470 (K3.0) ,, The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 ' Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ., 4. INSTALLATION • • • Refer to appropriate NFPA Installation Standards. ; 5. OPERATION . • • • During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. _ : . `. 6.. INSPECTIONS, TESTS AND MAINTENANCE • . ' "' • -. • Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. .. . K" • 7. AVAILABILITY • t " . -' The Viking Model VK470 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. • 8. GUARANTEE • ' For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES i Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 155 °F (68 °C) 100°F (38 °C) Red • Intermediate 175 °F (79°C) 150°F (65°C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT - - , Corrosion Resistant Coatings3: ENT , - • Footnotes • • 1 The sprinkler temperature rating is stamped on the deflector. `` • - • 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinklers location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ' t , • 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible'with or suitable for the proposed environment.For ENT coated sprinklers,the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. ' Wrench . Flats `. • ' Protective • ' Alit Sprinkler . • %VC Jir Cap a \�% . •i - •4- " .• t M; i .•,' f - • } • e r. �, 1 Ate,'., . . y . . - - - - - r '-i -1.. •. , .t . ' Figure 1: Standard Sprinkler Wrench 10896W/B • �•+ 4 , ,` �.i 4..*;. +' Form No. F_061011 Rcv 14.1 > . , , , - ,, I ` - . r ' ,• `' • . . I I .. Page 3 of 5 FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER ._, 4 .VK470 (K3.0) • • • The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 -•.Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com :: " Approval Chart Viking VK470, 3.0 K-Factor Residential Pendent Sprinkler , • For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13,refer to the design criteria. For Ceiling types refer to, NFPA 13,13R or 13D 2013 Editions Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water' Overall Length Part Number' Inches mm U.S. metric 2 Working Pressure Inches mm. 17147 VK470 1/2 15 3.0 '43.2 175 psi (12 bar) 2-1/4 58. • Ordinary Temp Rating Intermediate Temp ' Listings and Approvals ' Max. Coverage (155°F/68°C) Rating (175°F/79°C) - Minimum • Deflector Area° Installation Spacing • Ft.X Ft. Flow 4 Pressure 4 Flow 4 Pressure 4 to Type 5 Ft. ' y' (m X m) GPM PSI GPM PSI Ceiling c �L us 'NYC NSF (m) . (Umin) (bar) (LJmin) • . (bar) EU , • , • • - ,, .. Standard • I. 12 X 12 • 8 7.11 8 7.11 surface- . (3.7 X 3.7) (30.3) (0.49) (30.3) (0.49) mounted escutch . eons, the ' Microfast® I ' 1. •, ` ' Model F-1 - '14 X 14 ' . 10 • - 11.11 ' 10 .11.11 1-1/8 to 2 Adjustable See : See • 8 (4.3 X 4.3) (37.9) (0.77) (37.9) ,'(0.77) Escutcheon, Footnotes Foot- - inch or recessed 6 and 9 note 7 , (2.4) with the • • - Micromatic® 4 + Model , • • 16X16 . 13 18.8 w 13 18.8 E-1, E- • t (4.9 X 4.9) (49.2) (1.29) • (49.2)' `(1.29) 2, or E-3 ' . Recessed 4 , • . • Escutcheon ' • • - Footnotes , ' " ' Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. , . 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K- factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing.' Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. . ' °For areas of coverage smaller than shown, use the"Flow" and "Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. • , 5 Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European'Union. • ` . 'i • 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8. ' ' ' Meets New York City requirements, effective July 1, 2008. , • 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. - , ' 9 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard. .. surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. • i. • s ;-. { - Form No. F.061011 Rev 14.1 - , • * . . - �`" - + r ! Page4of5 O FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER .- NIICINGVK470 (K3.0) ti. • The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 • Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA __ (Also refer to the Approval Chart.) UL Listing Reauirements(C-UL-US-EU): • When using Viking Residential Pendent Sprinkler VK470 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage,or • • Calculated based on a minimum discharge of 0.1 gpm/sq.ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers:8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F 091699 -Care and Handling of Sprinklers.Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. 1 / . \ / , • 1 I \ I Il 1 1 1 11 I I . %(iIIF I>i MIUj\ %4illt-��x�.0 I>I lNish:. _. tlL..lagl lrItE7141 Wii �mik Sprinkler Wrench "'__ • "vI 4�P I 16036W/B** for T y�P A' ' IV ILII ,I- \ installing recessed I` Mill �,I� • _�" I sprinkler VK470 ��� - ■.A 1/2' ratchet Is required H Carefully slide the • (not available from Viking). F,=====-, wrench sideways _._____ . - --__: -_-__-- around the protective • �� - cap, ensuring engage- ■ • _ a (lent with the sprinkler ' . - wrench flats. Figure 2: Wrench 16036W/B for Installing Recessed Sprinkler VK470 , Ceiling Opening, Size: • • 2-5/16' (58.7 mm) minimum ' 2-1/2' (63,5 min) maximum - -I) If UUI 1/2' I (15 mm)• i �� ::::........... j4!ll'•'r`i>lir\Ili NPT �- 1-1/2' /(IFTRigiAlip 2' (50.8 mil) I I (38.1 rim)-47—.Il TP;\lj lel Maximum `a ' ,2-1/4' 1-3/4' Minimum u i1-1/2' i - (58 mm) .: � '(38.1 m) 1� �' •m • 1 _1-1/8' I Installed with a Installed with a • ' standard 1/8' (3.1 mm) Microfast Model F-1 (28.7 mm) surface-mounted escutcheon ' Adjustakile,Escutcheon • Figure 3: Sprinkler VK470 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Form No. F_061011 Rev 14.1 .. , . • Page 5 of 5 VIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK470 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ' Ceiling Opening Size: 2-5/16' (58.7 rim) minimum 2-1/2' (63.5 rim) maximum U 1 U U e-'� IF..I1.11.\ .,,,,E1 IIF iPl-W11 I I l -.1 ... ................. 1Nr1-1/8° (28,6 rim)1-1/8' (28,6 mm)1-3/4' 2' `_ #% Minimum (50.8 rim) • `a0. Minimum (44,5 mm) i Maximum • �,(1••e' - Maximum -1 1 Installed with a Installed with a threaded Micromatic Model E-1 Micromatic Model E-2 Recessed Escutcheon Recessed Escutcheon Figure 4: Sprinkler VK470 Dimensions with the Model E-1 and E-2 Recessed Escutcheons • • • • Form No. F_061011 Rev 14.1 (Added EU Listing) w Page 1 of 5 NIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK488 is a small high-sensitivity solder link and lever residential sprinkler designed for installation on concealed pipe e systems where the a y appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric'`), allows the sprinkler's ef- ficient use of available water supplies for the hydraulically designed fire-protection system.The operating element and special deflector characteristics meet the chal- ' lenges of residential sprinkler standards. . ti The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile small-diameter cover assembly installed flush to the ceiling.The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate as- sembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied,while also providing up to IA"(12.7 mm)of vertical adjustment. The cover assembly can be removed and reinstalled, allow- ing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW cOus Eu Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2013. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric") *Metric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Viking Technical Data may be found on Deflector Pins: Stainless Steel UNS-S30200 The Viking Corporation's Web site at Button: Brass UNS-C36000 http://www.vikinggroupinc.com. Seat Assembly: Brass UNS-C31600 The Web site may include a more recent Compression Screw: Brass UNS-C36000 edition of this Technical Data Page. Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom®Residential Concealed Pendent Sprinkler VK488 and Cover Plate Assembly must be ordered separately: Sprinkler: Part No. 18325 (includes a 165°F (74°C) rated sprinkler with a protective plastic cap covering the unit). Form No. F_073012 Rev 14.1 (Added EU Listing) t:4 • • • • Page 2 of 5 NIIKING® FREEDOMS RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Plate Assembly: Base Part No. 13504(2-3/4"diameter), Base Part No. 13642(3-5/16'I diameter), No. 15394(square cover plate, 3-5/16"diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix:Polished Chrome=F, Brushed Chrome=F-/B, Bright Brass=B,Antique Brass=B-/A, Brushed Brass=B-/B, Brushed Copper= E-/B, Painted White= M-/W, Painted Ivory = M-/I, Painted Black= M-/B • Temperature Suffix: 135°F(57°C)=A For example, cover 13504 with a Polished Chrome finish and a 135°F (57 °C)temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. . Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) ' • • Sprinkler Wrenches**: - A. Heavy Duty Part No. 13623W/B (available since 2006), or B. Head Cabinet Wrench Part No. 13619*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover.Plate Installer Tool Part No. 14867(available since 2007) ' - **Requires a W ratchet(not available from Viking).***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. • Sprinkler Cabinet: Part No. 01731A (available since 1971) • - 4. INSTALLATION . Refer to appropriate NFPA Installation Standards. • • 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature,the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing • assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. . 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. ' • • 7. AVAILABILITY . - Viking Sprinkler Model VK488 is available through a network of domestic and international distributors. See The Viking Corporation • web site for the closest distributor or contact The Viking Corporation. 8.' GUARANTEE ' For details of warranty, refer to Viking's current list price schedule or contact Viking directly. , • TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Nominal Maximum Temperature Rating Cover Plate Large Cover • Square Cover Temperature Temperature Ambient Ceiling of the Cover Base Part Plate Base Plate Base Classification Rating' Temperature2 Assembly (Required) Number' Part Number' Part Number' Ordinary 165 °F (74°C) 100°F (38 °C) 135°F (57 °C) 13504 13642 15394 Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass,Antique Brass, Brushed Brass, Brushed Copper, Painted _ White, Painted Ivory, or Painted Black - Footnotes • 1 The sprinkler temperature rating is stamped on the deflector. . • 2 Based on NFPA-13, NFPA 13R,and NFPA 13D.Other limits may apply,depending on fire loading,sprinkler location, and other requirements of the • Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. - Form No. F 073012 Rev 14.1 • • - F ! • • - .' l Page 3 of 5 . ® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation,-210 N Industrial Park Drive, Hastings MI 49058 • ':r Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com APProval Chart Viking VK488, 3.0 K=Factor Concealed Pendent Sprinkler For systems designed to NFPA'13D or NFPA 13R. For systems designed to NFPA 13,refer to the design criteria. For Ceiling types refer _ to NFPA 13,13R or 13D 2013 Editions Sprinkler Base SIN NPT Thread Size• Nominal K-Factor , ' Maximum Water •• Part Number' Inches mm U.S. metric' • Working Pressure a r 18325 VK488 1/2 15 . 3.0 43.2 • . 175 psi(12 bar) Ordinary Temp • . Max.Coverage Rating (165°F/74°C) - • ; Listings and Approvals' Minimum Areas Deflector to Spacing Flow° Pressurefi ,• Installation Type Ft.X Ft. GPM PSI Ceiling • c r 7 . Ft. ' ( ) w • NYC NSF ' (m) mXm I (L/min) (bar) _ . • • 12X12 8 7.1 . , (3.7 X 3.7) •,(30.3) (0.49) I •, c 14 X 14 ' 11 13.4 Concealed with See See See 8 ',. Refer to Figure 2 Cover Plate -Footnote 8 Footnote 8 ) f .. (4.3 X 4.3) (41.6) (0.92) ; Assembly , •and 10• Footnote 5 and 10 (2.4 16 X 16 13 • 18.8 • (4.9 X 4.9) (49.2) (1.30) • .. • Footnotes - 1 Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. " 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. . . . , 4 Listed by Underwriter's Laboratories, Inc.for use in the U.S.,Canada,and European Union. . - 5Meets New York City requirements,effective July 1,2008. ` 6 For areas of coverage smaller than shown, use the "Flow" and•"Pressure" for the next larger area listed. Flows and pressures listed are per .. sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing,indicated for the minimum;'Flow"and"Pressure" used. • , • 'UL Classified to: NSF/ANSI'Standard 61, Drinking Water System Components(MH48034). ' ' 8Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass,Antique Brass, Brushed Brass, Brushed Copper, Painted - White, Painted Ivory,or Painted Black 9. N r; 9 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Cover Temperature Rating is 135°F(57°C). Cover Part No.-135041,136421(large diameter),or 153941(square cover plate). 0 • , • A. • • 1 *' •• R� "'.t Form No. F_073012•Rev 14.1 '�•`i r '' r i , " .. 4 • • `1 K y, , , j• 3 Page 4 of 5 • "® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK488 (K3.0) • The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA .- (Also refer to the Approval Chart) • ' 1 's UL Listing Requirements(C UL-US-EU): f i • When using Viking Residential Concealed Pendent Sprinkler VK488 for systems designed to NFPA 13D or NFPA 13R,apply the listed areas of cover- -• age and minimum water supply requirements shown in the Approval Chart. ,y . For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The minimum , • required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage,or • Calculated based on a minimum discharge of 0.1 gpm/sq.ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. - • Minimum distance between residential sprinklers:8 ft.(2.4 m). • . • - r ` NOTICE Concealed sprinklers must be installed in neutral or negative pressure plenums only.- IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers.Also refer to pages ' • RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data,the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction,and also with the provisions of governmental codes,ordinances,and standards, • whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained . from the Authorities Having Jurisdiction. , • t' diameter opening Sprinkler and • t is required in' Adapter Assembly • the ceiling. - • • ' (Protective Cap ' } i • is removed for ' ` u installation--use _ , Wrench, , Sprinkler N Wrench Y • I • . • (Part No • 13623W/B)*# 111 ` 'is shown) #_ Step 1, Carefully slide the - . • ' wrench sideways around -- •, • ` . • the deflector and 'pins • ice- ' f t I_� , **A 1/2° ratchet is required ,• , Step a Carefully press the wrench ' • • • . (not available from Viking). . •• upward and turn slightly to ensure - engagement with sprinkler wrench flats. , ' ' Figure 1: Sprinkler Installation and Correct Use of Wrenches ,, , r"1 a' l Y .. * '' - Form No. F_073012 Rev 14:1. %1� • • Page 5 of 5 NIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com • 1/2" (15 mm) NPT � _ • 2-9/16° ZMIR 2-1/16° 2-1/8 (65 mm) _ (52 mm) (54 mm) Maxhum Minimum SIM I Er 2-3/4' (70 mm) or Note: Upon sprinkler' activation, the deflector descends 3-5/16' (84,1 mm) to approximately 13/16' (20,6 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation T; CUST4 - /] Q� p DO NOT PAINT Z (--) J � NIKING �O Identification of' Custom Paint Color: All custom color painted cover plates will 0 have an identifying label affixed to the inside of' -the cover that indicates custom ---.0-3-5/16 (84.1 mm)-11■-- color and will have a representative sample (a paint dot) of' the paint on the label. Figure 3: Identification of Custom Paint Color for Concealed Covers Figure 4: Square Cover Assembly 15394 r • • • • Form No. F_073012 Rev 14.1 (Added EU Listing) CFck Valve — 74 cise sSwing, Thrts ` The !~JIBCOG brass swing check valve prevents backfla�v by automatically clovtrtig tlec .!. rluid reverses direction. Swing checks may be installed in horizontal positions (or verlic ' 4 e=�'�� 4 with flow moving up). The NIBCO© brass check valve features threaded end connections for easy installation. Please refer to NIBCO technical data sheets, chemical resistance guides and catalogs for engineering and installation information, Choi NIBCO® check valves for the most specified, versatile and economical valve option in commercial and residentie applications. The NIBCO® check valve is backed by the NIBCO 2-year limited warranty. << Less Subrnfttel Overview a Valve pressure rating 200 psi/14 bar non-shock cold working pressure • Brass disc o Brass bonnet • NPT x NIPT end connections • Use in U.S. drinking water applications is prohibited after January 3, 2014 O Size range '1/2" to 4" Models Resources Warranty FA 's Actuation (/Valves/Actuation/) Ball Valves (/Valves/Ball.. al e �,! L i - tt 4.1fAHED1,6f. TH `FL0,:_ - '-" T.IL8A Icevb s /d aa,: isa . . 3`,era s Check ', elves Brass Body G Swing Type Check 200 PSI/14 Bar Non-Shoek Cold Working Pressure r , _ • IATERI1 L LIST y,, , ->z PART SPECIFICATION ,,,,,, `' �7 L Bonnet Bronze ASTM B 564 Allo}'C05700 # ' t ?._r`'hvn Bronze ASTM 8 1e.ploy C3500 11 -3. .fin_ Brass ASTN1 B 16 E L4 37/OO T1-4. Oise__ Brass ASTM B 124Alloy G377706 Threaded �; 5. Body Brass A5Trv1 B 504 Alloy C85700 or 1 i - Alloy C83600 SI-3 O 0 Solder Q 0 IMMIMEMII 4 ,`' - B ! ear p-!_- A ,,.I Lc E 1 tiEX A,R I TI-3 SI-3 NPTtnNPT CupxCup D i M ENS1 ONS---\NEl GHTS 0lntensians TI.3 S1.3 Tl-3, SI-3 T1-3 St-3 TI-3 SI-3 S1-3 WEIGHT Size A A B 13 C C P 13 9 TI-3 S1-3 In. mm m. 1n. m . In. mttr. In, mm. In. mot. En. mm. In. mm. In, mm. In. nun. In. nun. Lbs. Kg, Lbs. Kn. 'i2 15 2.05 52 2.13 54 1.50 30 1.50 38 1.00 25 I1,r3 IS 0.52 13 0.52 13 0.50 13 0,46 0,21 0.46 0.21 11. 20 2.32 59 2.99 76 1.57 40 1.57 40 1.22 31 0.88 22 0.70 18 0.73 18 0.75 19 0.00 0.30 0.66 0,30 1 25 2.72 69 3.66 93 1,77 45 1.77 45 1.50 38 1.13 29 0.94 24 0.94 24 0,91 23 0,92 0.42 0.92 0,42 PA 32 3.11 79 4.09 104 211 51 2.01 111 1.85 47 1.38 35 1.24 32 174 32 0.97 25 1.60 0.73 1.60 0.73 11/2 40 3.50 89 4.57 116 2.17 55 217 .55 2.11 54 1.03 41 1.42 36 1.42 26 1.09 28 1.79 0,81 1.79 0,81 2 50 4.29 103 5.51 140 2.64 67 2,64 G7 2.60 66 2.13 54 1.81 46 1,81 n6 t,34. 34 2.97 1,10 2.d7 1. fl 21 65 5.31 135 - - 3,31 8 - - 3.23 22 - - 2.26 57 - - . 5.29 2.4G - 3 80 5.30 160 . - - 338 913 - 3,78 96 - - 2.70 fig - - - 8.82 4,01 - - 4 ,., 100 7.38 _..190 - - 4.45 113 - - 4,81) 129.. - - 3.72 96 - - - - t3,23 6.01 - _ NOTFOO,U5EW.rrH POTABLE DAIMON*WATER APP?ICATR11 S AFTERJANIJARY3,2014. Y. rIMG0 INC.VJGSW It;AOOUA I t686•15ta MIUOIEOUOY ST,-E KHART,IN 45516.474D• USA-PH:r.2110.23..0227 �r,, ,,,. ., .....- -eev,:eon tit-ene.IJ17Limmitf1AIM ncFIPF PM',1 fi7.1 tflc Inn.mx,..L574.?9a?A5b ,...,-.. • - -7 ' Pipe Clamps „w Fig.28- "Stand-Off" Hanger&Restrainer for CPVC Plastic Pipe&IPS Steel Pipe** ®TOMO- • Size Range:—3/4°(20mm)through 2°(50mm) c, .us Material:—Steel, Pre-Galvanized LISTED Function:—Designed to be used as a hanger and restrainer for CPVC piping where ', the°stand-off°design will ease installation by eliminating the need for wood blocking. t Features: - •Flared edge design protects CPVC pipe from any rough or abrasive surfaces. •Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. •The'Stand-Off°design eliminates the need for wood block extension. 1 • •Can be installed on horizontal or vertical piping regardless of mounting surface orientation. 1 t' . • 3 •Attaches easily to wood structure with two hex head self-threading screws furnished with / \ product. I i . •Installs easily using rechargeable electrical driver with she(7.9mm)extension socket '".•, c eliminating impact tool damage to pipe. • •Attaches easily to steel,minimum 18 gauge(1.024mm)with(2) 1/4°x 1°tek type self drilling c B tapping screws. 1 ' 1 , • UL Listed as a hanger and a restrainer for fire sprinkler piping. ' . ` : t Approvals:—Underwriters Laboratory Listed in the USA(UL)and Canada (cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners ' supplied with product,or into minimum 18 gauge steel using (2) 1/4°x 1°tek type 's screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical ` .. /' restraint when installed on 3/8°(9.5mm)composite wood material. Use two Fig.27B Speed Nuts when used as a hanger and restraint. Use one Fig.27B Speed Nut on the upper 1-;,f installed screw when used as a hanger only. ' •1r 4 Order by:—Figure number and pipe size. • V ,,'' Pat.#7,455,268,Pat.#7,832,248 r . •i **With reduced spacing;consult factory. = • • -ke` cr,, ,� ` i 4 .� Ya %^ • r 1 Fig.27B Fg.27B "'�• , -.: 6 (1)Required -r. (2)Required^, 1 i /1/4•'---4*-- .6' •'i• High Side of fl PI ' i 147 Hanger ` Application '.+ tHanger Application Hanger •and Restraint , Application ;` - e \1�! -., Pipe Size A - 13C Max Hanger Approx. L'"• >' Spacing Wt./100 v. R`` Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft• (m) lbs. (kg) �, ,. 4ri.1' 28.9/4' 3/4" l20) _ 31/32" (n.o) 2" (50.8) 31/2" (88.9) 51/2.(1.67) . .18 (8.1) • 28-1 1" 25 5/ ( 1 3/ ( 1 1/ (; . ► {,'' ( 1 3 1s° 84.1 2 16" 55.6 3 2° ;9 6 (1.83) 21. (9.5) -.t -28-11/4 11/4" (32) 35/8" (92.1) 23/8" (60.3) . •31/2";,(88.9)-' 61/2,(1.98) ' • '23 :(10.4) 28-11/2 11/2° (40) 4° (101.6) 21/2' (63.5) 31/2" (88.9) - . 7 k.(2.13) 31 (14.0) „`� :;{ ••28-2 ' '2" (501• . 41/2°'(114.3) 211/16°(68.3)- '" 35/8'.(92.1)' ',","8"12.441• *• . 34,(15.4) R ® All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. :1114 Y Line by JF��•� 4Q Fire Protection Solutio _ ........„....„.,,,,. .. .,,...,.. r_ . f-%;i ,......r, Pipe Clamps . Fig.29-Double Offset Hanger& Restrainer for CPVC Plastic Pipe& IPS Steel Pipe** ®TOLC( 4. Size Range: Available in 3/4°(20mm)and 1°(25mm)pipe sizestrt '_3, .. . Material: Pre-Galvanized Steel 1.5" LISTED `; .0:.fi Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler (38.1mm) ' . o pipe. Provides double offset 11/2" (20mm)x 11/2" (2omm)from mounting surface.This `.;'7 '1 '•u'•' design will ease installation by eliminating the need for wood block extension and allow b:•, retro-fit attachment of hanger to sprinkler pipe. 4` it Features: ., � 1.5" ip,�Al o �+" ® (38.1mm) Thumb tab provides protection to restrain pipe in rough job site conditions.Tab '� 6. ',41;.. is not required to be bent for listed installation. Oo° OoO Y ' ,, . 0 Offset edge eliminates abrasion. 0 :� 0 Attaches easily to wood structure with two special#10 x 1" hex head ° .'"�•t �:.. self-threading screws furnished with product. � w 0 Can be used as a single offset hanger by aligning°dimples°with topof mounting ° , surface and utilizing two fasteners in two of the three holes provided. r Approvals: Underwriters Laboratories Listed in'the USA(UL)and Canada(cUL)as a 4"x hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements T' of NFPA 13, 13R and 13D. j i is" Finish: Pre-Galvanized Y,, Order By: Figure number and pipe size. l �,,. , Patent Pending Kt<<f **With reduced spacing,consult factory. o E..?lam r * 4 .2 O ` s i� O O O ) sly 1,, ' - (381mm) 1 - (38.1mm) s �,a _..ii k. 'Q] ..------- ..---- 0 CI . ' ',.--::t :_z: J3", "% " 0 "- 1 i.. lible Offset Y L �` Single Offset At �. . Install using a rechargeable electric drill fitted with a 5/16" (7.9mm)socket attachment with the special hex head self-tapping "r screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of y:t'-s the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not ---, l required for performance of the hanger/restrainer function. • x,' a All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. -`Y` B-Line • • City of La `� o� _ o Quints ,�� ` �r:, ' •` _ - �, Design and Development Department- ' s 78-495 Calle Tampico ,,, . La Quinta,CA 92253 • • /p1 Il , .tis., Telephone:(760)777-7125 Fax:(760)777-1233 D �^_�. �FMOF c��° www.la-quinta.org »� • JUL 18 2017 A Riverside County Fire Department - • . _{��p FIRE �' I IL [1U' . Riverside Office i A golc 2300 Market Street,Ste.150 COMMUNITY DEVELOPMENT DEPARTMENT ¢�' Riverside,CA 92501 \ (951)955-4777 FIRE REVIEW APPLICATION . • ❑ NEW 0 TENANT IMPROVEMENT PERMIT NO.F$5 2c(] - oD 11 I : - , • • - PROJECT;INFORMATION . ',(Please Print) . ' I . Project Name: A\feX\lc .cl •Gor. Z Sign: C9-- --- —. 1 Site Address: 53- 7 SO Aves.r\1 61,2t Cor-kZ Print: . FV idn G l e C.orc4i.21 I City & Zip: L/fj Q lA(n-t•ok q�a-5 3 . • I have read and understand that fees are DEPOSIT BASED FEES and there may be additional money due prior,to or • after project final. , • Pursuant to a Cooperative Agreement to Provide Fire Services,the Riverside County Fire Department serves as the City's fire department, and the County designee serves as the City's fire chief. Applicant recognizes this contracted arrangement and shall comply with County Fire Department directions. APPLICANT/CONTACT,INFORMATION' -_ BILLING INFORMATION: yame,cis Applicant info. I Applicant Name: M;cilia LL, CZ rrLscA . Contact Person: 3a Vl(....r GOrdmyO1 Bill To: ' Mailing Address: `E N—10S— )le Orb Av,... Mailing Address: .• F City&Zip: tnd I (D C.O -I I City&Zip: ' Phone Number: Cl(,6)Le ZS— Oe Fax: Phone Number: Fax: • Email: SC-I--f re-P►'D G+ic.r1 /� •nEn il: -, The person listed on"Billing Information"will receive ALL billing,correspondence and refunds for any work billed to this permit. Any changes in billing information must be made in writing to our office. A. APPLICATION TYPE (each application type includes a $5 technology enhancement fee) FIRE SPRINKLER SYSTEM ' . ." STORAGE TANKS _ • ❑ COMMERCIAL TI-1-9 HEADS NO FEE 0 DISPENSERS ONLY $217 . .❑ COMMERCIAL TI-.10+HEADS $619 0 ABOVE GROUND-1" TANK • $217 O RESIDENTIAL TRACT HOME-MODELS $619 0 ABOVE GROUND-EACH ADDITIONAL $32 • 0 RESIDENTIAL-EACH ADDITIONAL UNIT $126 EA 0 UNDER GROUND • $217 RESIDENTIAL-CUSTOM HOME $619 MISC • • FIRE ALARM SYSTEM - . .. '- . , 0 HAZMAT $S89 ❑ COMMERCIAL-SPRINKLER MONITORING $192 0 HIGH PILE RACK STORAGE $353 ❑ COMMERCIAL-FIRE ALARM SYSTEM $632 ' 0 NEW COMMERCIAL-UNDERGROUND . $701 WATER . • SUPRESSION SYSTEM• •• • '' r, - 0 FIRE FLOW REPORT $178 ❑. HOOD&DUCT $215 0 TECHNICAL REPORT RESEARCH $589 ❑ SPRAY BOOTH _ $215 ❑ SPECIAL INSPECTION $126 O CELL SITE $215 0 ITEMS NOT LISTED ARE ON A SLIDING $197 O OTHER SUPRESSION SYSTEM $215 SCALE STARTING AT These are Deposit Based Fees. There may be additional money due prior to or after project final. SS UPDATED 6-19-17