Loading...
2433�...�• Ia0•TE� `, ti � • With proper validation 'oe i.,,—. -t ,. this form constitutes an PE j -encroachment permit N -CITY OF LA OUINTA • t APPLICATION .,FOR PERMIT 4 - PUBLIC WORKS CONSTRUCTION (ENCROACHMENT)�� Iwsww� �� •. X `�oF TIiB9 Forthe construction 'of public or� private curbs, driveways, pavements, sidewalks, parking lots, sewers, water mains and other like public works improvements in connection with MINOR IMPROVEMENTS and APPROVED SUBDIVISIONS ` r Subdivision Improvement Permit — Class II I 2/21/96 DATE: Minor Improvement Permit Class IV LOCATION OF CONSTRUCTION 51-810 Ave. Morales _ 50-625 Calle Quinto i. (Street address or Description of Location) r Install Gas Service , PURPOSE OF CONSTRUCTION Sketch (attach construction plans if appropriate) DESCRIPTION•OF CONSTRUCTION Cut Street to make J � tis—la- See attached conditions DIMENSION OF INSTALLATION OR REMOVAL , w , 7 -1 <: Z\ 1 SIZE OF EXCAVATION; IF NEEDED. 1X-4_ t j J F • 2/22F96 EB 2 ' APPROXIMATE 2 s OXIMATE TIME WHEN WORK WILL -BEGIN . 1 6 e , APPROXIMATE TIME OF:COMPLETI N 2 z2 96 ESTIMATED CONSTRUCTION COST $ - r (Including, removal of all obstruction, materials, and debris, backfilling; com ' �, + ;":'Jt ' paction� and placing permanentresurfacing and/or replacing improvements) r�, - • In consideration of the granting of this permit, the applicant hereby.agrees to: , In'demnify,-defend and save the City, its authorized agents, officers, representatives and employees, harmless from and against'any and all ly, , penalties, liabilities or loss resulting from claims or court action and arising out of any accident, loss or damage'to persons or property happening or occurring as a proximate result of any work undertaken under the permit granted pursuant to this application. I. Notify the Adm inistrative.,Authority at least -twenty-four (24) hours in advance of the •tune when�uo�k will be start, Comply with all applicable City Ordinances, the terms'6nd conditions of the permit and all,appl ca to rules and -regulations of the City of La Quinta and to pay for any additional replacement necessary as the result of •th:i/ ork. ant OHgenT y oignai-ure OT Hp7(CA' ARB Inc. 72=400 Vista Chino Drive •`1000 Pal ;� _ Name of Applicant (please print) Business AddresV Telephone No.. Lund (619) 343-1180 Name of Contractor and Job Foreman Business Address Telephone 'No. 194079 566 l Contractor's License No. City Business License No. On Pile Applicant's Insurance Company Gall Liability ' Policy Number FEES: Subdivision Improvement Permit — Class y. Public improvements: 3%'of estimated construction costs • ' Private improvements:'3% construction r of estimated costs Minor, Improvement Permit —Class IV: See attached schedule �. , 4 Inspection Fee $ 120' ' 7 PERMIT VALIDATION Permit Fee lU. PERMIT NO. Penalty z 71 % Cash Deposit Surety Bond DATE APPROVED if required 2/29/96 EXPIRATION DATE TOTAL: $ 130. 2/2x/96 DATE Receipt No. - nn By" Received by Date y Administrative Authority f Recorded by TELEPHONE: (619):5W2g46i: 777-7075 � d '40101004 (dig) :3NOHd313S SLOL -LLL AuXnpnV .mNenaSIM" Ag �2 Z 03nSS131VO 3140 NOI1VWId'X3 •b I Z 03AOWddV 31VO 'ON 11WH3d No11VanVA 1IWH3d 92IC, L Ag p.PJoota sac Ag o.Atp.11 'ON 1010DOd 1V101 p.Jtmu j! Puog A "S•311o010 4110 NlttAd Uuuld O Z = Nj l8owtotul �InPftPt Pfwn3f ..5 ;AI 090 — U" 3uwu.AOmu11 Joulyy WOO uoganmm pt3numq jo %r MUfWMDJOW1 MAN 570, uon*nmu00 p3eWas. j0 %r muvz AoJOWt atlaitd Ilt gyp_ LYY.d UNUMAOJNWI UOIiIAIDQMS :9334 n.pWnN Aalpd %11'719o►t'I T'JC) Atnewo0 oueJnlul.s.3tJto1100v -ON Wuo?rl naultng Asp ON3aov2auo0 'oN.OUOOWI uwppV noumg utuaJo ®enuo040.uJfN X CPPV usumng 13ul n1d) lura"COV050 VJM O H N uea! v;o tugs OfiZL, �1/i F AID MA ie o.w BIN .gmleet au o SPUN �jq�le M W" y ,�Awmaloew am -low �� ID ALV M A.O as on f AM f i p+0 AID floo!r.et m aIr AtOWe'� wJtm p Illy amyl mom am .a 00 ammw t w unoy loll JnerAJ SMA tllwll Y AJIJ.IO V e1awWwm ov @IA Amok '.oaaapOt ,IO .I wwRlno /1NN" MuLAGO MP JlIn WRIumoun &mor Aat IO W a ojm l M t B A .t .uulnao ao flnu.dorm eety AL-- wloaw0 e7 .Wep A BOl -Kapp 7o AM p U10 Wnnw pW WM= uno, 4 MMS, WWI WnVOW Ml Jo' �►!il0��1 ' No PM Aut ttlrlttt ww U"M.IIWtY'BeAelelJw ON BllnawYg ..wu 'Y.a}{O aufM Optuol M QI 'AID .W ero SIM .wMo 'Alwunp111 A3 t..J6t Aguftl 3u0!10Of ftp 'UUV.O tall +O 6uputJ6 .t13 so U0Afjepltu0O u1 (ga wUlfAoW! 6=tlOtJ Jo/put 6uot;muu 3UftleWJfd Ouogo Put uoNate 'W� �I!II!31Pf4'lugfp Put tltufltw •180POM290 Ilt JO 1.0OWu 6u!pnpul) S 1500 NOLL0f1W1SN00 031VW11S3 NOLL31MOD 10 3WLL'31VWIXOWddv NID38111M MOM N3HM 3WLL 31VWIXOMddv 03033N dl'NOIIVAV0X3 d0 321S IVAOW3W HO NOLLV'IIVISNI 10 NOISNMIO ' a NOILI 131400 d0 NOLLdI 0530 18MMI N Oda I! weld uoponatuoa tjsutjRa3.� NpLL*SW1SN00d03SOdWfW T w W0001=600 Jo ealooe NSA$) Al WO UuLmd Umwm"wl_mnv( Itl pep — slutud 3116W.AaOWj uo!tlAlpgn V'001 SNOIS1AIOgf1S 03AOWMV PutS1N3W3AOWdW1 WONIri �� uooaftJuoa u! oufW.Aaoun I t;IOM aitgnd .4!1 utRo pug t{Q.UJ Jo" *LOOK •q01 6WVW 't1l)fltl.p!t 'BY.tINAtO '.AfMLUV 'Swm f3tAud JO a!IOnd j0 uoLnfU3ltuoo ftR JO j (1N3WH:)VOU3N3) NOl1.O( HISNOO S)IdOM mien d• 11WV3d VW NOIIV011ddV V1NIIID V'1 :10 Alto UWAO 3u"WROM of =vul11ucm 000111tH. u0nepou J.00JO la!m :310N, r } The following General and Special Provisions are attached to and made a part of Permit No. d�3� GENERAL PROVISIONS The following'shall always apply: ENROACHMIIVT ON PRIVATE PROPERTY: This permit authorizes work to be accomplished within City of La Quinta right of way ONLY. Whenever,construction extends within private property, it is the responsibility of the permittee for his contractors to secure permission from abutting property owners. Such authorization must be secured by the permittee prior to starting work. TRACKLAYING CONSTRUCTION EQUIPMENT: Cleated tracklaying construction equipment shall not be permitted to operate on any paved surface unless fitted with smooth -faced street pads. All mechanical outriggers shall be fitted with rubber street shoes to protect the paving during excavations. Rubber -tired equipment only shall be used in backfill operations in paved areas. If the existing pavement is scarred, spalled, or broken during the term of this contract, or if the pavement is marred, City of La Quinta shall request that these portions of road be resurfaced over their entire width. Resurfacing shall consist of one coat of two inches (2") of A.C. surfacing plus appropriate seal cost as specified above. PROTECTION OF TRAFFIC: All excavations and work areas shall be properly lighted and barricaded as deemed necessary by the City Engineer or La Quinta City Public Works inspectors. Suitable detours and detour signs shall be placed and maintained for the duration of the project. The City shall be notified. 24 hours in advance of any traffic detours or delineations. CARE OF DRAINAGE STRUCTURES: Any. drainage structure including corrugated metal pipe, concrete pipe, steel culvert and concrete structures encountered during excavation which necessitate removal shall be replaced in kind. In the event it becomes necessary to remove or cut existing drainage structures, City of La Quinta shall be notified prior to commencement of this work. Drainage structures and open drains shall be kept free of debris at all times for proper drainage. RIGHT OF WAY CLEANUP: Any surplus material resulting from excavation and backfill operations shall be removed from the right of way. All paved surfaces shall be broomed clean of earth and other objectionable materials immediately after backfill and compaction. Existing gutter line and drainage ditches shall be replaced to their original standard or better. All excess material shall be removed prior to paving. Water tanker shall be used, as required, to sprinkle the job site to keep down dust conditions and shall be used immediately after backfill. DE -WATER OPERATIONS: If de -watering operations are required and pumps are forcing water on City of La Quinta roads, it shall be. the responsibility of the permittee (contractor) to control this water and to provide off-street barricades when necessary. CLOSING STREETS: No street shall be closed. A minimum of one lane of traffic shall be maintained at all times to provide limited access for the adjoining property owners and emergency vehicles. In the event it is felt by the permittee that he must close a street for any length of time, permittee shall contact this office to obtain the necessary permission. SPECIAL PROVISIONS /17 7he following shall apply when indicated: ' NOTIFICATION: Permittee shall notify the City at (619)777-7075 at least 48 hours in advance of starting construction. Ul'ILITY CLEARANCE: (Substructures) Prior to making any excavation within the City of La Quinta right of way authorized by permit, the permittee shall contact all concerned utility companies relative to the location of existing substructures. Damage to existing substructures resulting from operations conducted under this permit shall be the sole responsibility of the permittee. CU HXI`Y CLEARANCE: (Surface Structures) No work shall be done under this permit until all utilities are clear of the proposed work site. The permittee shall notify all concerned utility companies of the proposed work. R4 PAVEMENT WIDENING: Area between the proposed concrete gutter line and the existing road.pavement shall be surfaced with inches of A.C. paving placed on inches of class aggregate subbase course having an "R" value of not less than and in conformance with City of La Quinta Road Improvement Standards and Specifications, Ordinance #461. PARKWAY GRADING: Area between the property line and top of the proposed concrete curb shall be graded to a slope of 1/4 inch to one foot (1). C(66_� GRADE CHECKING: City of La Quinta shall check grades upon receipt of plan and profile and/or grades as'established by a licensed engineer. R7 CURB REMOVAL FOR DRIVEWAYS: A portion of the existing concrete curb and/or curb and gutter (_feet) shall be removed: Curb and/or curb and gutter shall be saw cut prior to removal. Depressed curb, matching concrete gutter and concrete driveway approach shall be constructed in conformance with City of La Quinta Standard #207. R8 DRIVEWAYS: A.C. driveways shall be constructed as not to alter existing drainage pattern. Surfacing between the property line and the existing road paving shall be 2 1/2 inches of A.C. paving placed on ( of class aggregate base. Driveway construction shall conform to attached drawing. SIGHT CLEARANCE: Sight clearance of 600 feet in all directions shall be assured and maintained at all times. SOIL STERILIZER: The area to be surfaced shall be treated with soil sterilizer. Rate of application shall commply with the manufacturer's specifications. 11 COORDINATE WORK: The proposed work shall' be subordinated to any operation which the State of California or City of La Quinta may conduct in this area during the period of this permit. Work shall be coordinated with the State or City of La Quinta forces to preclude delay or interference with State of City of La Quinta projects. Rl SURVEY MONUMENTS: Prior to excavation or beginning of construction, all survey monuments which exist on the centerline of all streets or property lines when involved shall be completely tied out so they may readily and correctly be replaced by a licensed civil engineer or surveyor at the expense of the permittee. A complete set of notes showing the ties to these monuments shall be furnished to the City Engineer prior to the removal of any monuments. This office shall be notified upon completion or replacement of all survey monuments for proper project clearance. 1 PAVEMENT CUTTING: Pavement will be mechanically saw cut to a straight to a straight edge prior to excavation. Method of pavement cutting shall be approved through the office of the City Engineer. (Under no circumstances shall excavating equipment be used to excavate prior to cutting of pavement.) Excavation material shall be placed in such a position as to best facilitate the general flow traffic. Prior to final paving operations, any damage to pavement straight edges shall be corrected. LIMIT OF EXCAVATIONS: Excavations shall be limited to 1000 linear feet of open trench before backfill operations must V/ begin. All excavations shall be properly barricaded with lights overnight, on weekends and holidays for the protection of the traveling public. The Public Works Iaspector shall determine the suitability of excavation barricading in each case. No excavation shall remain open for a period exceeding five (5) days. No excavation shall be made unless the construction material is actually on the work site. BACKFILL MATERIAL: Backfill shall be free of brush, roots or other organic substance detrimental to its use for purposes V of producing an adequately consolidated backfill. Any material which the City of La Quinta deems unsuitable (spongy or saturated material) which is encountered during excavation shall not be used for backfill, but shall be supplemented or replaced by an approved sand or gravel. CRI�16 BACKFILL SAND: Backfill shall be approved transit -mix sand or equivalent and shall be'placed in lifts of not greater than three. feet (3') and vibrated using vibrotamper or equivalent equipment. Alternate methods may be substituted, but in any case, l a relative compaction of 95 percent shall be attained with the structural section of the roadway. R19 BACKFELL PLACEMENT: Backfill shall be applied in layers of not more than 50 percent of the total depth of the trench before flooding or a maximum of five-foot (5') lifts where trenches are of excessive depths. Care is to be exercised that the backfill material is not subjected to extreme swell by flooding operations. Backfill material shall be placed so that the resulting compaction shall be not less than 90 percent or equivalent to the surrounding ground, whichever is the greater compaction. Where ponding or flooding is used for a maximum settlement, adequate dikes will be constructed to retain the water. Where jetting is used, the jets shall be of sufficient length to reach the bottom of each layer and the water supply shall be continuous. Z_ COMPACTION TESTS: If so required by the inspector, compaction tests shall be made at intervals of not more than 1000 feet and a minimum of one (1) test on each road. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R COMPACTION TESTS: If so required by the inspector, compaction tests shall be made for each crossing or service line. One (1) copy of each test shall be forwarded to the City Engineer for approval and filed prior to making permanent repairs. Compaction tests shall be made as outlined in Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. R20 TEMPORARY PAVEMENT REPAIRS: After completion of backfill and compaction operations, a temporary patch consisting of 2 inches of SC -800 shall be placed on a prepared subgrade. The SC -800 temporary paving shall be placed after a maximum of 3000 linear feet of trench has been excavated and backfill operations completed, but in no case shall the placement of the temporary pavement exceed a five (5) day limit. R21 PERMANENT PAVEMENT REPAIR: After backfill and compaction have been completed, a temporary patch consisting of two inches (2") of SC -800 shall be placed immediately. A permanent patch of inches A.C. surfacing placed on a inch class base shall be placed no later than days after completion of temporary road repair. R22 FOG SEAL: A fog seal coat consisting of an application of asphaltic emulsion shall be applied over all patch areas as determined by the City Engineer. STREET RESTRIPING: Where street striping is still visible on streets to be excavated, such striping shall be replaced upon completion of permanent repairs. R24 TREE RELOCATION OR REMOVAL: Tree relocation within the City of La Quinta road right of way shall be accomplished by a licensed, bonded and insured tree service, and handled safely without interference or hazard to the traveling public. It shall be the responsibility of the permittee to maintain the tree in a vigorous growing condition at its new location. Trees to be removed shall be in sections which can be handled safely without interference or hazard to highway traffic. The entire width of the tree stump shall be removed and disposed of so that no debris remains in view of the highway. The stump hole shall be backfilled and thoroughly compacted as specified in the following paragraph. Where is becomes necessary to restrict traffic, the work shall be restricted to a maximum of 500 feet at any one time. Adequate signs, flagmen and or barricades shall be provided to protect the traveling public at all times. Large holes resulting from tree removal shall be backfilled and compacted to not less than 90 percent or equivalent to the surrounding ground, whichever is the greater compaction as determined by the impact or field method. Compaction tests shall comply with Section 6.3.01 of the Standard Specifications, Division of Highways, State of California, dated January 1973. 1 2. 3. SPECIAL CONDITIONS --PERMIT NO. 2433 --- ARB CONST. / THE GAS CO. --- In addition to the standard permit conditions, the following shall apply: All work shall be performed in accordance with the latest edition of the Standard Specifications For Public Works Construction. Permittee shall be responsible for providing continuous dust and erosion control. Streets shall be kept clean. They shall be completely cleaned at the end of each working day and more frequently if required. 4. Contractor shall comply with the local noise ordinance. Operation.and maintenance of equipment within one .half mile of human occupancy shall be performed only during the following time periods: October lst to April 30:. Monday -Friday 7:00 a.m. to 5:30p.m. Saturday 8:00 a. in. to 5:00p. in. May 1st to September 30: Monday -Friday 6:00 a. m.- to 7:00p.m. Saturday 8:00 a. m. to 5:00p. m. Work. shall be prohibited on legal holidays including Sundays. 5. Permittee/contractor shall assume responsibility for repair of any pavement damage to any public or private street and for any damage to other City streets or facilities as a result of work performed under this permit. 6. Advance warning signs and traffic control shall be installed and maintained in accordance with Cal Trans Standards or the. Work Area Traffic Control Handbook (WATCH Manual). It shall be the permittee's responsibility to' detour and barricade this site. 7. Street closures shall not be permitted. A minimum of one travel lane on paved surface shall be maintained with flagmen at all times. 8. Prior to excavating, the permittee shall contact Underground Service Alert at 1(800) 422-4133. 9. Should additional work, materials, or modifications of the work be required in order to meet city standards, safety requirements, signage requirements, or to fit actual field conditions, the work shall be performed by the permittee as directed by and to the satisfaction of the City Engineer at no cost to the City of La Quinta. Special Conditions - Permit No. 2,433 Page 1 of 2 SPECIAL CONDITIONS ---PERMIT NO. 2433 continued 10. All work shall be coordinated with the City's contractor and others working within the area as directed by and to the satisfaction of the City Engineer. 11. All backfill and subgrade soil shall be compacted to 90% relative dry density, all backfill soil within the top 2' of finish pavement surface shall be compacted to 95 % relative dry density, all base material shall be compacted to 95% relative dry density. 12. All excavations at or near the travel way shall be backfilled and paved at the end of every workday as directed by and to the satisfaction of the City. Engineer for the protection of the traveling public. 13. A11 landscaping, irrigation, decorative rock, decorative concrete, lighting etc. shall be replaced to its original condition. 14. Access and egress to all local properties shall be maintained at all times. 15. Permanent pavement replacement section shall be one inch greater than existing. 16. Gas main shall be installed behind the curb, and the street crossing shall be a bore operation. 11 Special Conditions - Permit No. 2433 Page 2 of 2