BMCH2018-004778-49S CALLE TAMPICO
c&ht- 4 4 0914r(u
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT.
Permit Type/Subtype: MECHANICAL/
Application Number: BMCH2O18-0047
Property Address: .78311 DEACON DR W
APN: 770210030
Application Description:. MCLIN RESIDENCE / HVAC CHANGE OUT
Property Zoning:
Application Valuation: $14,400.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
FEB 2 3 2018
CITY OF LA QUINTA)
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20, C36 License No.: 977333
c
Date: Z 23 )g Contractor
OWNER -BUILDER DECLARATION
I hereby affirm'under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031:5, Business and Professions Code: Any
city or county that requires a permit to construct, after, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec: 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of'sale.).
(_) I, as owner of.the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/23/2018
Owner:
STEPHEN MCLIN
78311 DEACON DR W
LA QUINTA, CA 92253
Contractor:
A#1 SERVICES HEATING & AIR CONDITIONING
78206 VARNER RD #D-189 ,
PALM DESERT, CA 92211
(760)565-2691
Llc. No.: 977333'
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
-'Slt�I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: FALLS LAKE FIRE AND CASUALTY COMPANY Policy Number: FLA006188
I certify that in the performance of the work for which this permit is issued, I .
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith
comply with those provisions.
Date: 7i�1 1Ize / Applicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT.
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result.of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read.this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
A,
Date: g Signature (Applicant or Agent)
Date: 2/23/2018
Application Number: BMCH2O18-0047.
Owner:
Property Address: 78311 DEACON DR W
STEPHEN MCLIN
APN: 770210030
78311 DEACON DR W '
Application Description: MCLIN RESIDENCE / HVAC CHANGE OUT _ .
LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $14,400.00
Applicant:.
Contractor:
IE INC
A#1 SERVICES HEATING & AIR CONDITIONING
31225 LA BAYA
78206 VARNER RD #D-189
WESTLAKE VILLAGE, CA 91362
PALM DESERT, CA 92211
(760)565-2691
------------------------------------------------------------------------------------------------
Uc. No.: 977333
Detail: HVAC CHANGE OUT - 21 SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARMIS) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016
CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT.
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00• .
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$39.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$78.02
Total Paid for CHANGEOUT: $117.03,
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$98.83
Total Paid for PERMIT ISSUANCE: $98.83
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0•
$10.0.0
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0 .
$5.OQ
Total Paid for TECHNOLOGY. ENHANCEMENT FEE: $5.00
TOTALS: $231.8
'1 .
a�iGGrt�I�V
PERMIT #
.
PLAN LOCATION:
Project Address:. :78311Deacon Drive West
.
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 4 ton / 90,000 BTU complete HVAC system
Patio/Porch SF
Email:
Applicant Name: Steven Schnierer '
•
State Lic: 686310 City Bus Lic:
Address:'31225 La Baya Drive Suite 213.
State Lic:. ` City Bus Lic:
City, ST,.Zip: Westlake Village, CA 91362
•Tehaphone: 818-735-7876
Email:.
swschnierer@roadrunner.com
Valuation of Project $ 14,250.00
Contractor Name: A#1 Services Heating & A/C
New SFD Construction:
Address: 78206 Varner Road #D-189
Conditioned Space SF
City, St, Zip Palm Desert; CA 92211
Garage SF
Telephone: 760-565-2691
Patio/Porch SF
Email:
Fire Sprinklers SF
•
State Lic: 686310 City Bus Lic:
v
Arch/Eng-Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip ... .
Construction Type: Occupancy:
Telephone:
Bedrooms:
Stories:
# Units:
Email:-.
State Lic:. ` City Bus Lic:
Owner's Name: Steve and Cathy McLin • -
New Commercial / Tenant Improvements:
Address: 78311 Deacon Drive West
Total Buildipg SF
City, ST, Zip La Quinta, CA 92253.
Construction Type: Occupancy:
Telephone:
?
Property
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E.
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3)
Project Name:' Steve & Cathy McLin Date Prepared: 2018-02-22
A. General Information
CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one.
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
Steve & Cathy McLin
02
Date Prepared
2018-02-22
03
Project Location
78311 Deacon Dr W
04
Building Type
Single family
05
CA City
La Quinta "~
06
Dwelling Unit Name.
HOUSE
SC System
SC System
CFA served
system a
Dwelling Unit Conditioned
Installing new SC
07
Zip Code
92253
X0015267
;Floor Area (ft2 )
Location or Area
by this SC
ducted .
containing.
system
more than 40
entirely new
entirely new
'C
L
:I.
Number of Space
system?
09
Climate Zone..
15
10
Conditioning (SC) Systems in
1
SYSTEM 1
WHOLE HOUSE
5267
r
this Dwelling Unit:
Yes
B. Space Conditioning (SC) System.Information {"
01
02
03
04 '
0 05 16"
1 06 ; '
07
08
09
10
Is the SC
Installing'a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
"Installing
Installing
Identification or
Location or Area
by this SC
ducted .
containing.
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
WHOLE HOUSE
5267
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 418-A020010886A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2018-02-22 15:27'36
Report Version: 2016.1.006
Schema Version: rev 10/16
HERS Provider: CHEERS
Report Generated: 2018-02-22 15:27:37
CERTIFICATE OF COMPLIANCE CF111-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)IE and F)
01
02
03 • .
04
.05
06
07
08
09
10 .
11*
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
-Required
New or
Identification
- System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct .
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type.
Duct Length
R -Value
Central gas
All new
Central split
All new
This field or
This Feld or
SYSTEM 1
furnace
heating
AFUE
0:8
AC
cooling
SEER
21
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums R6.(CZ 1 10,12 and 13) and R8 (CZ 11 and 14-16)
CF211 and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed i' ducted rystems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <=15% or <= 30% leakage to outside, or seal all accessible leaks. t l . "� I'
CF2R and CF311-MCH-25-H Refrigerant Charge verification required when refrigerant containing c'ompoents are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF311-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required.
Exceptions I
Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage -Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, cr Refrigerant Charge MCH -25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with, or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 418-A020030886A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2018-02-22' 15:27:36
Report Version: 2016.11. 006
Schema Version: rev 10/16
HERS Provider: CHEERS "
Report Generated: 2018-02-22 15:27:37
CERTIFICATE OF COMPLIANCE - CF111-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement.
L I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Patty Hernandez
Patty }f____d
Company:
Signature Date:
Permit E Raters
2018-02-22
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
City/State/Zip:
91362•
�
Phone:
5-7876
Westlake Village CA �
s818j,,
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:`r "
261
1 _._.... ,
1. The information provided on this Certificate of Compliance is true and correct. .
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility:for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for -approval with this Pudding permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made•available with the bwlding:`permit(s) asued for the building, and made available to the enforcement agency for all applicable.
inspections. I understand that a registered copy of this Certificate of Compliance is`requiredto be included with -the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Cara Goldberg .
C"'�"0oulb- '
Company:
Date Signed:
A#1 Services Heating & Air Conditioning
2018-02-22 '
Address:
License:
78026 Varner Road #D-189
977333
City/State/Zip: '
Phone:
Palm Dessert.CA 92211
(760) 342-3610
Digitally signed by CHEERS'". This digital signature is provided in order to secure the content of this registered
document, and in no way implies 'Registration Provider responsibility for the accuracy of the information.
Registration Number: 418-A020010886A-000-000-0000000-0000 Registration Date/Time: 2018-02-22 15:27:36
CA Building Energy Efficiency Standards 2016 Residential Compliance. Report Version: 2016.1.006
Schema Version: rev 10/16
HERS Provider: CHEERS
Report Generated: 201&-02-22 15:27:37