BMCH2017-001278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BMCH2O17-0012
Property Address:
52650 DEL GATO DR
APN:
770290007
Application Description:
HVAC CHANGE OUT
Property Zoning:
Application Valuation:
$15,000.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
`sur 4 4vQum&
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
D
JAN 2 3 2017
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20, C36 License No.: 686310
Date: 1 li Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires -the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. � . B.&P.C. for this reason
Date:
Owner;
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 1/24/2017
Owner:
CAM & WANDA GARNER
52650 DEL GATQ DR
LA QUINTA, CA 92253
Contractor:
HARRISON ENTERPRISES INC DBA GENERAL AIR
31170 RESERVE DRIVE
THOUSAND PALMS, CA 92276 .
(760)343-7488
Llc. No.: 686310
WORKER'S COMPENSA70N DECLARATION
I hereby affirm under penalty of perjury one oa the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofth work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658
I certify that in the performance of :he work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 11 Applicant: C a
WARNING: FAILURE TO SECURE WORKERS' CO1APENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owne-, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance.of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and st.—te that the above information is correct.
I agree to comply with all city'and county ordirances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: i 1 Signature (Applicant or Agent):
Application Number:
BMCH2O17-0012
Property Address:
52650 DEL GATO DR
APN:
770290007
Application Description:
HVAC CHANGE OUT
Property Zoning:
Application Valuation:
$15,000.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
Date: •1/24/2017
Owner:
CAM & WANDA CARNER
52650 DEL GATO DR
LA QUINTA, CA 9:253
Contractor:
HARRISON ENTERPRISES INC DBA GENERAL AIR
31170 RESERVE DRIVE
THOUSAND PALMS, CA 92276 .
(760)343-7488
Llc. No.: 686310
-----=------------------------------------------------------------------------------------•---
Detail: HVAC CHANGE OUT - 19 SEER/70AFUE SPLIT SYSTEM [2016 ENERGY] CARBON MONOXIDE ALARM(S) TO BE•INSTALLED PRIOR TO FINAL INSPECTION.
PER 2016 CALIFORNIA BUILDING CODES
r
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT QTY
AMOUNT
BSAS S61473 FEE
101-0000-20306 0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION- BSA:
$1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT —SPLIT -SYSTEM PC
101-0000-42600
0
$38.00
Total Paid for CHANGEOUT:
$114.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$96.27
Total Paid for PERMIT ISSUANCE:
$96.27
r
TOTALS:
4j
r
Bin.#
City 0f Quinta ,
Building 8t Safety Division
V f P.O. Box 1504,78-495 Calle Tampico
La.Qllinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
P it y
Project Address: 52650 Del Gato Drive
Owner's Name:. Cam &.Wanda Garner
A. P. Number.
Address: 52650 Del Gato Drive
Legal Description:
City, ST, Zip: La Quinta, CA 92253
Contractor. General Air Conditionins;;>
g
Telephone: 760-777-1487 � � ss x
Address: 31170 Reserve Drive
ProjeetDescription: Replace 3 ton / 70,000 BTU complete .
City, ST, Zip: Thousand Palms, CA 92276
HVAC system
Telephone: 760-343-7488
V; -�
(;ity Lie. #;
State Lic. # : 686310
Arch., Engr., Designer.
Address:
City, ST, Zip:
Telephone: `���
State Lia #: rw
Name of Contact Person: Steven Schnierer
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. FL: #Stories: # Units:
Telephone # of Contact Person: 8.18J35-1876
Estimated Value of Project: $15,000.0) .
APPLICANT: DO NOT WRITE BELOW THIS UNE
N
Submittal
Req'd
Reed
TRACKNG
PERTAW FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Calci.
Reviewed, ready for corrections
Plan Check Deposit. .
Trus Cates.
Called Contact Person
Plan Check f=alenee
Title 24 Calci.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2i° Review,.ready for correctionsfissue
Electrical
Subcontactor list
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.h
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''d Rcview, ready for earrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.LP.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC)
Project Name:
CAM & WANDA GARNER I Date Prepared:
CF111-ALT-02-E
(Page 1 of 3)
2017-01-23
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF111-ALT-02 document for each dwelling unit.
01
Project Name
CAM & WANDA GARNER
02
Date Prepared
2017-01-23
03
Project Location
52650 DEL GATO DRIVE
04
Building Type
Single family
•1 OS
CA City
LA QUINTA ; _
06
Dwelling Unit Name
CAM & WANDA GARNER
07
Zip Code
92253.1
. 08 .
Dwelling Unit Conditioned
containing
system
more than 40
.,afar`,
-i
Floor Area (ftZ)
7983
Served
System (ftZ)
�C
177
Number of Space
feet of ducts?
09
Climate Zone
15
+"
i 10
Conditioning (SC) Systems in
1
Yes
Yes
Yes
No
this Dwelling Unit:
No
B. Space Conditioning ($C) System Information.
O1
02
03
04
U 11105
! 06' +
07
08
09
10
SC System
SC System
CFA served
Is the SCitrt'
system a
Installing
refrigerant
Installing new SC
Installing
Installing
. Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ftZ)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
WHOLEHOUSE
7983
Yes
Yes
Yes
No
No
No
Altered spaceconditioning
system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 15O.2(b)1Diib)
This section does not apply to this project.
Registration Number: 417-A020007350A-000-000-0000000-0000
Registration Date/Time: 2017-01-23 14:59:35
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016. 1.005 Report Generated: 2017-01-23 14:59:36
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components-
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central gas
All new
Central split
All new
This field or
This field or
SYSTEM 1
furnace
heating
AFUE
0.8
AC
cooling
SEER
19
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation: y
CF2R-MCH-bl-E - Space Conditioning Systems w.
wo'R6-(CZ
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums 1-10 1-2 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are Installed in ducted Systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15% or <=10% leakage to outside, or seal all accessible leaks. U
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable In CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. -
Exceptions:
g
Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Test requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
. a��f
E. Entirely New or Complete Replacement Duct System, with or without'Equipment Cha,,ngeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
trThis section d es n� t'apply to th s pr ject.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC)
This section does not apply to this project.
Registration Number: 417-A020007350A-000-000-0000000-0000 Registration Date/Time: 2017-01-23 14:59:35 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017=01-23 14:59:36
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE CF111-ALT-024
Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. I certify.that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Patrick Somers
PatV6ck1Scm rs
Company:
Signature Date:
General Air Conditioning
2017-01-23
Address:
CEA/ HERS Certification Identification (if applicable):
31170 Reserve Drive
686310
City/State/Zip:
Thousand Palms CA 92276
Phone:
760343-7488
Responsible Person's Declaration statement,
I certify the following under penalty of perjury, under the laws of the State of California: i
1. The information provided on this Certificate of Compliance Is true and correct.(
ding
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility -for the bu li design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part land Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for -approval with this building application.
permit
S. ' I will ensure that a registered copy of this Certificate of Compliance shall be made�available�with tio he-6uilding.permit(sko )-&ued for the building, and made available to the enforcement agency for all applicable
inspections.) understand that a registered copy of this Certificate of Complianel ce is -required to be included With the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Un tched t �'i��
Responsible: Designer Signature:
= , °� �a,iY
Patrick Somers
.t
�atvi ck. S'ovvierk
Company:
Date Signed:
General Air Conditioning
2017-01-23
Address:
License:
31170 Reserve Drive
686310
City/State/Zip:
Phone:
Thousand Palms CA 92276
760-343-7488
Digitally signed by CHEERS'"'. This digital signature is provided in order
to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number: 417-AO200073SOA-000-000-0000000-0000 Registration Datef ime: 2017-01-23 14:59:35 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-01-23 14:59:36
Schema Version: rev 10/16