Loading...
BMCH2017-0238i 78-495 CALLE TAMPICO 4 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0238 Property Address: 45480 DESERT FOX DR APN: 604241003 Application Description: LOPEZ RESIDENCE / HVAC CHANGE OUT Property Zoning: Application Valuation:. $15,750.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 [JUN 13 2017 J �I CITY OF LA QUINTf COMMUNITY DEVELOPMENT DEPARTMENT] LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 763937 Date: (P T3 I 11 Contractor:, esu, T7� C OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) lam exempt under Sec. B.&P.C. for this reason Date Owner: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/13/2017 Owner: VICTOR LOPEZ 45480 DESERT FOX DR LA QUINTA, CA 92253 Contractor: VOTTA ENTERPRISES INC DBA COMFORT AIR 72248 NORTHSHORE ST STE 101 THOUSAND PALMS, CA 92276 (760)320-5800 Llc. No.: 763937 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ofthg�ork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5034539 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date; 3 �-i Applicant,�� WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is correct. I hereby affirm under penalty of perjury that there is a construction lending agency for I agree to comply with all city and county ordinances and state laws relating to building the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Lender's Name: 1 1 P Date: 3 (� Signature (Applicant or Agent): Lender's Address: Date: 6/13/2017 Application Number: BMCH2017-0238 Owner: Property Address: 45480 DESERT FOX DR VICTOR LOPEZ APN: 604241003 45480 DESERT FOX DR Application Description: LOPEZ RESIDENCE / HVAC CHANGE OUT LA.QUINTA, CA 92253 Property Zoning: Application Valuation: $15,750.00 Applicant: Contractor: IE INC VOTTA ENTERPRISES INC DBA COMFORT AIR 31225 LA BAYA 72248 NORTHSHORE ST STE 101 WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA -92276 (760)320-5800 ---------------------------- ----------------------------------------------------------------- Llc. No.: 763937 Detail: HVAC CHANGE OUT - 25 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO.FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-203060 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $38.00 Total Paid for CHANGEOUT: ' $114.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY. AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 1`. CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) Project Name: VICTOR LOPEZ I Date Prepared: CF1R-ALT 02-E (Pagel of 3) 1 2017-06-09 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF111-ALT-02 document for each dwelling unit. 01 Project Name VICTOR LOPEZ 02 Date Prepared 2017-06-09 03 Project Location 45480 DESERT FOX DRIVE 04 Building.Type Single family 05 CA City La Quinta 06 Dwelling Unit Name VICTOR LOPEZ SC System SC System CFA served Dwelling Unit Conditioned refrigerant 07 Zip Code 92253 08 Z Floor Area (ft) 1830 Location or Area by this SC ducted containing system more than 40 entirely new entirely new ' Name Number of Space System (ft) 09 Climate Zone 15 30 Conditioning (SC) Systems in 1 Alteration Type System 1 f• " 1830 this Dwelling Unit: Yes I .— 9..E !ew"`__— I.f•"'•,'-•" I.: L_-" k%"•'"]..E'-'•-•f:!!"__-z Irl B. Space Conditioning (SC) System Information l[J1 y {ry5 , 01 02 03 "N. ` 04 05 06 07"~ 08 09 10 is the SCS I Lalli g a x r"" r% t Jr— M SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 1830 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 15O.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020194537A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-06-09 09:45:23 Report Version: 2016.1.005 Schema Version: rev 10/16 HERS Provider: CaICERTS Report Generated: 2017-06-09 09:45:52 CERTIFICATE OF COMPLIANCE CF111-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -111 -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 it 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling. Efficiency Efficiency. Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value . Central gas All new Central split All new Less than or System 1 furnace heating AFUE 80 AC cooling SEER 25 Setback equal to 40 R-8 components components feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF311-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 154 or <= 10% leakage to outside; or seal all accessible leaks. CF2R and CF311-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF311-MCH-23 Airflow Rate >=.300 CFM'per ton required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements.. - . - $ Leakage. a b —,,. ' k . , Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH 23, or'Refrlgerant Charge MCH 251 } : i t k. e 5 ri Existing duct systems constructed, insulated or sealed with asbestosare exemptifrom MCH-20�Duct Lea Page Test hg requirements. ' ? E. Entirely New or Complete Replacement Ducta ysltem, with or without7Equipment Changeout,(Sections 150.2(b)Wiia: and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or -Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 217-A020194537A-000-000-0000000-0000 Registration Date/Time: 2017-06-0909:45:23 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-09 09:45:52 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: / Jacoby, Ian cyan Jacoby Company: Signature Date: i PERMIT E RATERS 2017-06-09 09:45:23 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village CA 91362 818-735-7876 Responsible Person's Declaration statement` I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3'of.the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials; components, and manufactured devices for -the building' design or system design identified on this Certificate of Compliance conform to the lan�"^ requirements of Title 24, Part 1 and Part 6 of the California Code of.R gtio { 4. The building design features or system design features identified on It Certificate of Compliance are consistent.with+the informatfon.provided on other,applicatile compliance documents, worksheets, l w h .. e, ...�,� ., � � n r calculations, plans and specifications submitted tome en-fgrcement a4egency9forkapprovaf�wit�h this building perm application. �` { S. I will ensure that a registered copy of this Certificate of,Compliance shall be marl available with the building permt(s)' ssued for<the building, andmade available;to3he enforcement agency for all applicable , inspections. I understand that a registered copy of this Cert $cate of Comp fiance is required to be included with the documentation,tthe builder pro torthe building owner at occupancy. _yides Responsible Designer Name: n Responsible Designer Signature: Jacoby, Ian cyan �aco y Company:. Date Signed: i PERMIT E RATERS 2017-06-09 09:45:23. Address: License: 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village CA 91362 818-735-7876 Easy to Verify at CaICERTS.com K.1 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the contentof this registered document, and in noway implies Registration Provider responsibility f the accuracy of the inforr Registration Number: 217-A020194537A-000-000-0000000-0000 Registration Date/Time: 2017-06-09 09:45:23 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-09 09:45:52 Schema Version: rev 10/16