Loading...
BMCH2017-038778-495 CALLE TAMPICO Ci 0 D �iIM1A�il/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0387 D W Property Address: 53920 AVENIDA DIAZ APN: 774152009 AUG I 1 Application Description: ULRICH RESIDENCE / HVAC CHANGE OUT Z��1 7 J Property Zoning: CIT! OF LA QUINTA Application Valuation: $10,852.00 COMMUNITY DEVELOPMENT DEPARTMENT Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 LICENSED CONTRACTOR'S DECLARATION. I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 686310 <Date 31 ` Contractor: �i.sg..�►��—� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5; Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within'one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State. License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. Q. Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 01/2017 DAVID ULRICH 53920 AVENIDA DIAZ LA QU INTA, CA 92253 Contractor: - HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALPAS, CA 92276 (760)343-7488 Llc. No.: 686310 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one cf the following declarations: I have and will maintain a certifica-.e of consent to self -insure for workers' compensation, as provided for by Section 37C0 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, a3 required by Section 3700 of the Labor Code, for the perfo-mance of the work for which this permit is issued. My workers' compensation insuran--e carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658 ' I certify that in the performance oz the work for which this permit is issued, I shall not employ any person in any manner sc as to become subject to the workers' compensation laws of California, and agree tl-at, if I should become subject'to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: FS3l n Applicant: zu.irL Y" WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FCR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNC WLEDGEMENT IMPORTANT: Application is hereby made to the Building Official fora permit subject to the conditions and restrictions set forth on the application. 1. Each person upon whose behalf this app'ication is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to :he work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date o- issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the . above-mentioned property for inspection purposes. n Date: Signature (Applicant or Agent): —T� i Date: 8/31/2017 Application Number: BMCH2017-0387. Owner: Property Address: 53920 AVENIDA DIAZ DAVID ULRICH APN: 774152009 53920 AVEN IDA DIAZ Application Description: ULRICH RESIDENCE / HVAC CHANGE OUT LA QUINTA, CA 92253 Property Zoning: Application Valuation: ,$10,852.00 Applicant: Contractor: IE INC HARRISON ENTERPRISES INC DBAGENERALAIR • 31225 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)343-7488 --------------------------------------------------------------------------------------------- Llc. No.: 686310 Detail: HVAC CHANGE OUT - 14 SEER/80 AFUE PACKAGED SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. FINANCIAL •R • DESCRIPTION ACCOUNT QTY AMOUNT . BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - PACKAGED UNIT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - PACKAGED UNIT PC 101-0000-42600 0 $25.33 Total Paid for CHANCEOUT: $63.33 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 , Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY.AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMEMT FEE: $5.00 TOTALS:.0 i f Bin. # CQty. of La Quin td Buiiding 8T Safety Division P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 53920 Avenida Diaz Owner'sName:.David Ulrich A. P. Number. Address: 53920 Avenida Diaz Legal Description: Contractor. General Air Conditioning City, ST, Zip: La Quinta, CA 92253 Telephone: 949-412-9100 Address: 31170 Reserve Drive Project Description: Replace 4 ton pacPage unit City, ST, Zip: Thousand Palms, CA 92276 Telephone: 7.60-343-7488 ' State Lic. # : 686310 City Lie. 9. Arch, Engr., Designer. Address: City., ST, Zip: Telephone: ` State Lia #:- ' -=.w3j ", y. ~ Name of Contact Person: Steven Schnierer Construction Type: Oc::upancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.:#Stories: #Units: Telephone # of Contact Person: 818-735-7876 Estimat6d Value of Project: $10,852.00 . APPLICANT:.DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACMG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Coles. Reviewed, ready for corrections Plan Check beposit. . Truss Calcs. Called Contact Person Pian Check Balance Titre 24 Calcs. Plans picked up Construction " Flood plain plan Plans resubmitted." . Mechanical _ Grading plan tad Review, ready for correctionstissue Electrical Subcontactor List Called ContactPerson Plumbing " Grant Deed Plans picked up SALL H.O.A. Approval Plans resubmitted Grading 1Di SOUSE.- '^' Review; ready for corrections/issue Developer rtpact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3) Project Name: DAVID ULRICH I Date Prepared: 2017-08-30 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name DAVID ULRICH 02 Date Prepared 2017-08-30 03 Project Location 53920 AVENIDA DIAZ 04 Building Type Single family 05 . CA City La Quinta06 Dwelling Unit,Name HOME SC System SC System � system a refrigerant 07 . Zip\Code 92253 US Dwelling Unit Conditioned Identification or Location or Area by this SC ducted containing Floor Area (ft)1522 more than 40 entirely new entirely new 'Name Number of Space System (ft) 09 Climate Zone 15 -10 Conditioning (SC) Systems in 1 I Alteration Type SYSTEM 1 WHOLE HOME I , this Dwelling Unit: Yes B. Space Conditioning (SC) System Information 1"A_J'! 37 Tt ____ _ Ff:�i F711 01 02 03 04 V 005 L ` 06 07 08 09 10 Is the SC t,. nrl Installing.a, , 3 M" 4 r; } tf . s ctrtl j SC System SC System CFA served system a refrigerant Installing new'SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new 'Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? I Alteration Type SYSTEM 1 WHOLE HOME 1522 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System; Greater Than 40 Feet (Section 150.2(b)iDiib) This section does not apply to this project. Registration Number: 417-A020113150A-000-000-0000000-0000 Registration Date/Time: 2017-08-30 12:43:00 HERS Provider: CHEERS. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-30 12:43:00 Schema Version: rev 10/16 1 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05. 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value . Central All new Central All new This field or This field or SYSTEM 1 packaged HP heating AFUE 0.8 packaged HP cooling SEER 14 Setback section isnot section is not .components components applicable applicable Required Documentation:, t .7 CF2R-MCH-01-E -Space Conditioning Systems4' - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1`10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF311-MCH-20-H - Duct Leakage Test required when heating or cooling components are -installed inducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <=15% or <= 10% leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow.Rate >= 300 CFM per ton required when MCH -25 is required. - .r Exceptions:, Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changei�oat (Sections 150.2(b)lDiia and 150.2(b)1E, F) t #This section does no apply to th s project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC) This section does not apply to this project. Registration Number: 417-A020113150A-000-000-0000000-0000 Registration Date/Time: 2017-08-30 12:43:00 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-30 12:43:00 Schema Version: rev 10/16. CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Salvador Correa salvadorcorrea Company: Signature bate: I Permit E Raters 2017-08-30 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive RCN13245 City/State/Zip: �Phone: Westlake Village CA 91362 {'l 818.735-7876 Responsible Person's Declaration statement./' certify the following under penalty of perjury, under the laws of the State of California: k dl 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility;for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured'devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for -,approval with this building permit application. rl r� _0 .,I,,(—n )s k• 5. 1 will ensure that a registered copy of this Certificate of Compliance shall beimadepavailablle_ with the b ilding:perm€t(s) €issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance €srequired to be €nclude'd with'the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: { YY�Y4� y #, �k l3 i s'G�k�i #�'.^a�.z.TL��'es€s..i Patrick Somers Responsible Designer Signature: 1 "'c'"a+1. K€x^i:"YP•st ke•RM Sa7vadarCorrew{ata-i Company: Date Signed: General Air Conditioning 2017-08-30 Address: License: 31170 Reserve Drive 686310 City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Digitally signed by CHEERS'"'. This digital signature is provided in order to secure the content of this registered -document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 417-A020113150A-000-000-0000000-0000 ' Registration Date/Time: 2017-08-30 12:43:00 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Schema Version: rev 10/16 HERS.Provider: CHEERS Report Generated: 2017-08-30 12:43:00