Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BMCH2017-0351
78 495.CALLEJAMP..ICO „ :1 LA QUINTA, CALIFORNIA 92253 T,i,&t 4 4 Qu&t6j DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0351 Property Address: 78955 DULCE DEL MAR APN: 643110015 ( ,' Application Description: SHAHNIAN RESIDENCE/ HVAC CHANGE IOUT j a� Property Zoning: AUG © 9 2017 Application Valuation: $29,500.00 n Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 763937 -71 1Ick 1 l i Cgntractor.:. fl OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from'the. Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure; prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work', himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State license Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/9/2017 Owner: SHAWN SHAHNIAN 78955 DULCE DEL MAR LA QUINTA, CA 922S3 Contractor: VOTTA ENTERPRISES INC DBA COMFORT AIR 72248 NORTHSHORE ST STE 101 THOUSAND PALMS, CA 92276 (760)320-5800 Llc. No.: 763937 WORKER'S COMPENSAT!ON DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. tZ� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the perfornance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Polity Number: WSD5034S39 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree tha-, if I should become subject to the workers' compensation provisions of Section 3:00 of the Labor Code, I shall forthwith comply with those provisions. a ,gyp _Annlirant- S� WARNING: FAILURE TO SECURE WORKERS' CONPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR :N SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless, the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. l Date: � 04 1`l Signature-(oJEAgent):�'� Date: 8/9/2017 . Application Number: BMCH2017-0351 Owner: Prop'ertyAddress: " "789SS DULCE DEL MAR SHAWN SHAHNIAN APN: 643110015 78955 DULCE DE_ MAR Application Description: SHAHNIAN RESIDENCE /HVACCHANGE OUT LA QUINTA, CA 9.2253 Property Zoning: Application Valuation: $29,500.00 Applicant: Contractor: IE INC VOTTA ENTERPRISES INC DBA COMFORT AIR 31225 LA BAYA 72248 NORTHSHORE ST STE 101 WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)320-5800 --------------------------------------------------------------------------------------------- Llc. No.: 763937 Detail: (2) HVAC CHANGE OUTS - 25 SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED. PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • .. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $76.00 Total Paid for CHANGEOUT: $228.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT* TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: # 7 � 1 k City of La Quinta / Btrilding sr Safety Division `� P.O. Box 1504,78-495 Calle Tampico La.QLdnta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # 7 _ 55Dulce Del MarOwner's Name:Shawn Shahnian FProject.Address: .Number: Address: 78955 Dulce Del Mar al Description: Contractor: Comfort Air City, ST, Zip: La Quinta, CA: 92253 Telephone: 818-636-5930fsg?;z ' Address: 72248 Northshore Street Suite 101 ProjectDescription: Replace 5 ton / 90,000 BTU complete . City, ST, Zip: Thousand Palms, CA 92276 HVAC system ' Telephone: 760-320-5800 �_"'' µ ;:r: . State Lic. #: 763937 City Lic. it,: Replace 4 ton / 70,000 BTU complete HVAC•system Arch., Engr., Designer Address: City., ST. Zip: ter;. Telephone: State Lic. #: -� .. ; Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Steven Schnierer Sq. Ft.: #Stories: #Unit;: -Telephone # of Contact Person: 818-73577876 Estimated value of project: $29,500,00 . APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACMG PERMIT FEES' Plan Sets Plan Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit: . Truss Calcs. Called Contact Person Plan Check Balance Tide 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan P° Review, ready for correctionsfkssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN HOLSE:- ''d Review; ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person Pub. Wks. Appr Date of permit issue School Fees ' Total Permit Fees CERTIFICATE OF COMPLIANCE CFI11-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 1 of, 3) Project Name: SHAWN SHAHINIAN Date Prepared:. 2017-08-07 A. General Information - CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CFIR-ALT-02-document for each dwelling unit. 01 Project Name SHAWN SHAHINIAN 02• Date Prepared 2017-08-07 03 Project Location 55 DULCE MAR 04 Building Type Single family 05 CA City La Quinta _06 Dwelling Unit Name HOME SC System SC System CFA served systema refrigerant 07 Zip Code 92253 ` ' 08 Dwelling Unit Conditioned 3400 Location or Area by this SC ducted containing Floor Area (ftZ) more than 40 entirely new entirely new. Name Served System (ft) system? component? components? ;r Number of Space SC system? 09 Climate Zone 15 10' Conditioning (SC) Systems in 1 Yes No No No this Dwelling Unit: B. Space Conditioning (SC) System Information"I C77 , t 01 02 03 04 05 06 07 OS 09 10 Is the SC ti Installing a aV;1- .Iu ZR r*e +A tx :fes t rFt SC System SC System CFA served systema refrigerant Installing new'SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new. Name Served System (ft) system? component? components? feet of ducts?. duct system? SC system? Alteration Type SYSTEM 1 WHOLE HOME 1700 Yes Yes Yes No No No Altered space conditioning system SYSTEM 2 WHOLE HOME 1700 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)iDiib) This section does not apply to this project. Registration Number: 417-A020107938A-000-000-0000000-0000 Registration Date/Time: 2017-08-07 10`.09:52 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-07 10:10:42 Schema Version:.rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new \ Central split All new This field or This field or SYSTEM 1 furnace heating AFUE 0.8 AC cooling SEER 25 Setback section is not section is not components components applicable applicable Central gas All new Central split All new I This field or This field or SYSTEM 2 furnace heating AFUE 0.8 AC o cooling SEER 25 Setback section is not section is not components components applicable applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems € 'i - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R&(CZ`1-101'1'2 and 13) and R8 (CZ 11 and 14-16) CF2R and COR -MCH -20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 10% leakage to outside, or seal all accessible leaks. _< CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceotions ITi C Duct from --Duct Leakage systems registered with HERS provider as previously sealed are exempt MCH -20 Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerarit 6har`ge MC—H225. Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. 3.ds fa ! K:i 4'S.eF €4a :'cJ ✓7=i 'Fla„C WIZ,9 & 'III �_=V€ li.Y E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 417-A020107938A-000-000-0000000-0000 . CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-08-07 10:09:52 Report Version: 2016.1.006 Schema Version: rev 10/16 HERS Provider: CHEERS Report Generated: 2017-08-07 10:10:42 CERTIFICATE OF COMPLIANCE UlR-ALT-024 Alterations to Space Conditioning Systems (formerly CF-iR-ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name; Documentation Author Signature: Stephanie Shryock StxJ�haru�shryoc7v Company: Signature Date: Votta Enterprises, Inc. dba Comfort Air 2017-08-07 Address: CEA/ HERS Certification Identification (if applicable): 72248 Northshore Street #101 City/State/Zip: I l� _Phone: Thousand Palms CA 92276', `760-320-5800 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibilit'y,for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for -approval this building permit application. s. �:._iJ f� it P � _ 5. 1 will ensure that a registered copy of this Certificate of Compliance Shall bbe made available with thh building..permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is-required`Lo be included withthe documentation the builder provides to the building owner at occupancy. Responsible Designer Name: 13ir1ttiCMh I4»:S{havuP:°sk+yoc7�Caut3wrvr�ed.) Responsible Designer Signature: Tracy Garza Company: Date Signed: Volta Enterprises, Inc. dba Comfort Air 2017-08-07 Address: License: 72248 Northshore Street #101 763937 City/State/Zip: Phone: . Thousand Palms CA 92276 760-320-5800 Digitally signed by CHEERS'". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 417-A020107938A-000-000-0000000-0000 Registration Date/Time: 2017-08-07 10:09:52 . HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-08-07 10:10:42 Schema Version: rev 10/16