Loading...
BMCH2017-025578-495 CALLE TAMPICO Ct 0 D �HMIACt/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0255 Property Address: 79910 FIESTA DR APN: 600060036 Application Description: GUIZA / HVAC CHANGEOUT - 18SEER/ 80AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $14,000.00 VOICE (760).777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: CHRISTOPHER GUIZA 79910 FIESTA DR . LA QUINTA, CA 92253 Date: 6/22/2017 Applicant: Contractor: A - AVIS PLUMBING HEATING & AIR CONDITIO /AA A - AVIS PLUMBING HEATING & AIR CONDITIO 600 EAST VALLEY BLVD ®600 EAST VALLEY BLVD COLTON, CA 92324 JUN 2 2 2017 COLTON, CA 92324 0 (909)825-3600 CITY OF LA QUINTA Llc. No.: 630503 DESIGN AND DEVELOPMENT DEPARTMENT________________________________ ---------------- -.-------------------- ---- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 630503 Date: ZsL "'1 Contractorf _ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State • License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the -following declarations: 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of a work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by S ion 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9138414 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT.AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official fora permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work For 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned property for inspection purposes. r . Date: 6/22/2017 Application Number: BMCH2O17-0255 Owner.: Property Address: 79910 FIESTA DR CHRISTOPHER GUIZA APN: 600060036 79910 FIESTA DR ' Application Descri.ption: GUIZA / HVAC CHANGEOUT - 18SEER/ 80AFUE SPLIT SYSTEM LA QUINTA, CA 92253 Property Zoning: Application Valuation: $14,000.00 Applicant: Contractor: A - AVIS PLUMBING HEATING & AIR CONDITIO A - AVIS PLUMBING HEATING & AIR CONDITIO 600 EAST VALLEY BLVD 600 EAST VALLEY BLVD COLTON, CA 92324 COLTON, CA 92324 (909)825-3600 --------------------------------------------------- Llc. No.: 630503 -=-- ----- Detail: HVAC CHANGE OUT - 18SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO -------------------------------- BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 •L] N FORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1:00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $38.00 Total Paid for CHANGEOUT: $114.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY . AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin.# City ofLa Quinta. Building a Safety Division P.Q. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Pefinit # Project Address: 79910 Fiesta Drive Owner's Name:. Christopher Guiza A. P. Number. Address: 79910 Fiesta Drive Legal Description:. City, ST, Zip: La Quinta, CA92253 Contractor. A-Avis'Plumliing Heating &Air Telephone: 760-290-5392 Address: 600 E Valley Blvd Project Description: Replace 5 ton A/C in back yard, City, ST, Zip: Colton, CA 92324 coil, & 80,000 BTU furnace -in closet Telephone: 909-825-3600 .,� City Lie. #.: State Lie. #: 630503 Arch., Eagr., Designer Address: City., ST, Zip: Telephone: Y `� v,>a•. State Lic #:�i<' Construction Type:. Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.:#Stories: #Univ: Name of Contact Person: Steven Schnierer Telephone # of Contact Person: 818-735-7876 Estimated Value of project: $14,000.00. APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACK NG PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit. . Thus Cafes. Called Contact Person Plan Check Balance Tide 24 Cafes. Plans picked up Contraction Flood plain plan Plan resubmitted ' Mecharilcal Grading plan 2nd Review, ready for correctionsrosue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed _ Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"' Review; ready for correctionslssue Developer Ioipact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) Project Name: CHRISTOPHER GUIZA I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2017-06-20 A. General Information CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. O1 Project Name CHRISTOPHER GUIZA 02 Date Prepared 2017-06-20 03 Project Location 79910 FIESTA DR 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name CHRISTOPHER GUIZA Dwelling Unit Conditioned I talli g,a 07 Zip Code 92253 ; A OS Floor Area (ft2) 1900 SC System CFA served } . refrigerant Installing new SC Installing Installing Installing r' Identification or Number of Space by this SC 09 Climate Zone " ; . 15 ` _."....:-- 30 Conditioning (SC) Systems in 1 Name >� -' System (ft) this Dwelling Unit: component? . , ,rx— --- F4 _;101.�9-1_ -_ a F-.-....., err- 111ss-� 'r— iF . IF, r r B. Space Conditioning (SC) System* lnformatiii n 01 02 03 ',_ 04 kw 05. 06 07 08 09 10 ""ls the SO I talli g,a V It SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 1900 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section1S0.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020210065A-000-000-0000000-0000 Registration Date/Time: 2017-06-20 15:26:13 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-20 15:26:10 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF111-ALT-024 Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating . Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 80 AC cooling SEER 18 Setback section is not section is not components components applicable applicable Reduired Documentation: CF2R-MCH-.01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-50, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <=15% or <= 10% leakage to outside; or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable In CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >=300 CFM per ton.required when MCH -25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from_MCH-20 Duct Leakage Testing requirements., --. - - Heating -only systems and Air Handler Furnace changes do not require verificatlon of A r Flow. MCH -23; orRefrigerant Charge MCH-;' _ € .y ek pI c' e� r 1� -Existing duct systems constructed, insulated or sealed with asbestos -are exempt from MCH"1 0 Duct1 akage Testingregwroements a ., . _....... E. Entirely New or Complete Replacement OuctSy"stem, with or without, Equipment Changeout.(Sections 150.2(b)1Dii2 and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 1S0.2(b)1C) This section does not apply to this project. Registration Number: 217-A020210065A-000-000-0000000-0000 Registration Date/Time: 2017-06-20 15:26:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-20 15:26:10 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF111-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: �^ Jan Jacoby, Ian dacobl Company: Signature Date: i PERMIT E RATERS 2017-06-20 15:26:13 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village CA 91362 t 818-735-7876 Responsible Person's Declaration statement'. I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer): 3. That the energy features and performance specifications, materials, comp ,nnents, and manufaacctured devices for..the building design or. system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Lode of dations 11 1 4. The building design features orsystem design features identified on this Certificate of Compliance are consistentwith the Informatitimprovided on other, pplicable`compliance documents, worksheets, calculations, plans and specifications submitted.to the enforcement agency for approval with this building permit application. 5. I will ensure that a registered copy of his Certificate of,Compliance shall be;made'a_v_ailablewith th"e butldjngpermit(s)�issued forthe ;building, and tnade available towtfie enforcement agency for all applicable , inspections. I understand that a registered copy of this Certi{icate of comp) anceis,required to be included with the.documentaation-the�builder provides to the building owner at occupancy. Responsible Designer Name: 11..E Jacoby, Ian Responsible Designer Signafure: V�/ cyan �acobJr Company: Date Signed: i PERMIT E RATERS 2017-06-20 15:26:13 Address: License: 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village CA 91362 818-735-7876 Easy to Verify at CaICERTS.com Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility fc r the accuracy of the inform Registration Number: 217-A020210065A-000-000-0000000-0000 Registration Date/Time: 2017-06-20 15:26:13 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-20 15:26:10 Schema Version: rev 10/16