Loading...
BPAT2017-006678-495 CALLE TAMPICO D • "i - Q"'& VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 9225FAX (760) 777-7011 3 DESIGN &DEVELOPMENT DEPARTMENT FAX (760) 777-7153 BUILDING PERMIT Date: ' 9/20/2017 Permit Type/Subtype: PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN Owner: Application Number: BPAT2017-0066 DOREEN ROBERTS z Property Address: 61532 FIRE BARREL DR 61532 FIRE BARR=L W ME APN: 764500006 LA QUINTA, CA 93253 Application Description: ROBERTS RESIDENCE / PATIO COVER a Property Zoning: ¢ w Application Valuation: $5,890.00 o z F N W :E Contractor: Contractor: <5 r)- LIFETIME PATIOS LIFETIME PATIOS Li - D Co P O BOX 5806 P O BOX 5806 L -U o LA QUINTA, CA 92248 LA QUINTA, CA 92248 Cn U Q . z. (760)772-0013 Llc. No.: 770843• ------------------------------------------------------=---------------------------------=---- LU a LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Cl License No.: 770843 ��( Date: Contractor./ e-1� .OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for"the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's WORKER'S COMPENSAT':ON DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9204676 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINt4L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made.to the Building Official for a permit subject to the conditions and restrictions set forth on this:application. 1: Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owned, and -the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicztion becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. . I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatves of this city to enter upon the above -mentio d property for inspection purpcses. Date: Signature (Applicant c r Age t): I • Date: 9/20/2017 Application. Number: BPAT2017-0066 Owner: Property Address: 61532 FIRE BARREL DR DOREEN ROBERTS APN: 764500006 61532 FIRE BARREL Application Description: ROBERTS RESIDENCE / PATIO COVER LA QUINTA, CA 9.2253 Property Zoning: Application Valuation: $5;890.00, Applicant: Contractor: LIFETIME PATIOS LIFETIME PATIOS P 0 BOX 5806 P O BOX 5806 LA QUINTA, CA 92248 LA QUINTA, CA 92248 (760)772-0013 --------------------------.------------------------------------------------------------------- Llc. No.: 770843 Detail: 589 SF WEATHERWOOD PATIO COVER. PER 2016 CALIFORNIA BUILDING CODE r I FINANCIAL •• • DESCRIPTION ACCOUNT CITY AMOUNT ' BSAS 581473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00. DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $101.84 DESCRIPTION ACCOUNT_ CITY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600 0 $100.32 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.77 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.77 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 0: Bfn.# City Of La Quinta Building 8L Safety Division 0P.O. Box 1504,•78-495 Calle Tampico La.Quinta, CA 92253 • (760) 777-7012 Building Permit Application and Tracking Sleet Permit # Project Address: 61532 Fire Barrel Dr. owner'sxame:. Doreen Roberts / Robert Wheaton A. P. Number. Address: 61532 Fire Barrel Dr Legal Description: City, ST, zip: La Quinta, CA, 92253 Contractor. Lifetime Patios. Telephone: 760 564 5134 ,•..c ` `. ¢ Ml Address: PO BOX 5806 ProjectNscription: City, ST, zip: : La Quinta, CA, 92253 Weatherwood Aluminum Attached Telephone: 760 777 2650' �?;;>' , . Open Lattice Shade Structure. . State Lic. #: B 770843 City Lic #; 3258 Arch, Engr., Designer Address: City., ST, Zip: Telephone: Y ' State Lic. #: Name of contact Person: Charles Tunstead Construction Type:. occu•3ancy: Project type (circle one): New Add'n. Alter Repair Demo Sq.Ft.; 589 #Stories: #Units: Telephone # of Contact Person: .760 668 1700 Estimated Value of Project: $5890.0.) APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACMG TERM TFEES Plan Sets Plan Cheek submitted item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cales. Called Contact Person Plan Check Sa:ance Tide 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2`! Review, ready for correctionsfissue Electrical Subeontaetor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:. 3" Review; ready for correctionslissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr - Date of permit issue School Fees Total Permit?ees Rear Property Line North i F, 29.5' 1 Proposed Weatherwood Open Lattice Shade Structure: Beachwood Color ` F. F LA QUINTA ITY UILDI a & SAFETY DEPT. Roberts/Wheaton AF PROVED . - 61532 Fire Barrel Dr: FOR ONS RUCTION ' ^ ' La •Quinta, 92253 _ DA E `ate jj f l - .760 564 5134 - T; ` -Proposed Courtyard Weatherwood Lattice Shade Structure. 12' 1 Beachwood Color r.. .' Casita Driveway + J ' Lifetime Patios F PO Box 5806 La Quinta; 92248- . _ 760.777.2650 - `, — 8/23/17 • '. o Fire Barrel Drive. -PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. POINT OF CONTACTS INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW: ,E/�GJNEEf?J/4d�v CONTRACTORS: PLEASE CONTACT DURALUM 26030 ACERO SURE 2D0 PHONE: (949) 305-1150* BUILDING DEPARTMENTS: PLEASE CONTACT 4STEL ENGINEERING MISSION VIEJO, CA 92691 FAX (949) 305.1420 HOMEOWNERS: PLEASE REQUEST ANY INFORMATION THROUGH YOUR CONTRACTOR STRUCTURAL ENGINEER OF RECORD: DUSTIN K ROSEHNK. SE 5885 POINT OF CONTACT: MARIE -DOMINIQUE SETA SE 5987 I DESIGN PARAMETERS GOVERNING CODES: THE DESIGN OF ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE 2012/2015 INTERNATIONAL BUILDING AND RESIDENTIAL CODES, 201312016 CALIFORNIA BUILDING AND RESIDENTIAL CODES, ASCEISEI 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AND THE 2015 ALUMINUM DESIGN MANUAL - COLUMNS BEARING ON CONCRETE SLAB IS IN ACCORDANCE WITH 2012/2015 IRC AND 2013/2016 CRC SECTION A_ H_105.2 FOR 10 PSF RESIDENTIAL CONSTRUCTION AND ACI 318-14 FOR 20, 25 AND 30 PSF RESIDENTIAL AND COMMERCIAL CONSTRUCTION. 1. IN RESIDENTIAL APPLICATIONS: _ CRC AND IRC APPENDIX H, CBC AND IBC CHAPTER 16, CBC 8 IBC APPENDIXCHAPTER I. ROOF LIVE LOAD: 10 PSF (20 POUNDS PER SQUARE FOOT AND GREATER MAY BE USED FOR COMMERCIAL APPLICATIONS AND R ROOF SNOW LOADS: 10, 20, 25, 30,40 8 50 PSF (SNOW LOADS AT GROUND LEVEL). O E + ��� 2 IN COMMERCIAL APPLICATIONS: ® t� r 0 'b C8C AND IBC CHAPTER 16. i••' � , ��r �- ROOFLIVELOAD:20PSF. CI �T � DEPT. ROOF SNOW LOADS: 20, 25, 30,40 8 50 PSF (SNOW LOADS AT GROUND LEVEL). BUILDL F� ]qWIND SPEED DESIGN PARAMETERS: e�y,�.-'-."`"OR THE USEWITH THE 20C WIND 12/203 CRCJRED IN THIS C. DI DE THE EQUIRED CRC/ RC WIND SPEED BY SQRT(06 ORT ARE 110, 120,130 MPH, EXPOSURES 8 D C (BASED N THE CB F L ' �+CBC I IBC WIND SPEED 110MPH 120 MPH 130 MPH Q (ND D I OIMPH EXAMPLE: IF CRCORC WND S EED SI65 MPH ETHE PATIO CO ER CONSTRUCTION SMALL BE BASED ON 85 MPH S01R1'JOT6E' 144 SNOW LOADS DESIGN PARAMETERS: L__� 1. R IS THE RESPONSIBILITY OF THE CONTRACTOR FOR THIS PROJECT TO VERIFY SNOW LOADS WITH THE LOCAL AUTHORITY HAVING JUN. TABULATED SPANS FOR SNOW LOADS HAVE BEEN ADJUSTED FOR ROOF APPLICATIONS. 2. WHERE SNOW LOADS OCCUR, THE CONTRACTOR FOR THIS PROJECT SHALL VERIFY WITH THE LOCAL AUTHORITY HAVING JURISDICTION WHERE DESIGN FOR SNOW DRIFTING I OR SLIDING IS REQUIRED PER ASCE 7-10, SECTION 7.7 AND 7.8, 3. DESIGN FOR SNOW DRIFT AND SLIDING HAVE BEEN CONSIDERED IN THIS SET OF DRAWINGS FOR ATTACHED COVERS WITH GROUND SNOW LOADS OF 30 PSF OR LESS. WHERE SNOW LOADS DRIFTING AND I OR SLIDING OCCUR REDUCTION FACTORS PER SHEET S2.1 OR L21 SHALL BE APPLIED TO THE STRUCTURE 4. DESIGN FOR SNOW DRIFT AND SLIDING FOR DETACHED COVERS AND FOR ALL COVERS WITH GROUND SNOW LOADS HIGHER THAN 30 PSF IS BEYOND THE SCOPE OF THIS REPORT AND REQUIRES SITE SPECIFIC ENGINEERING. SEISMIC LOAD DESIGN PARAMETERS: SEISMIC DESIGN BASE SHEAR 17 POUNDS PER LINEAR FOOT PER WIDTH OF COVER, CONSIDERING THE FOLLOWING DESIGN PARAMETERS: 1. SITE CLASS: D - 2. SEISMIC DESIGN CATEGORY: E 3. MAPPED SPECTRAL RESPONSE COEFFICIENTS: SS =1.50, SI = 0.6, SDS =1.0, SDI = 0.50 4. RESPONSE MODIFICATION FACTOR R=125 5. RISK CATEGORY II 6. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE IN COMPLIANCE WITH ASCE 7-10 SECTION 12.8.1.3. AS A RESULT, THIS SET OF PLANS CAN BE USED AT ANY SITE WITH Ss> 1.50, CONSIDERING SS =1.50. OTHER DESIGN PARAMETERS: 1. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBC SECTION 1605.3.1. 2. THE FREESTANDING AND ATTACHED COVERS NOTED HEREIN ARE DESIGNED AS'OPEN STRUCTURES,' IN ACCORDANCE WITH ASCE/SEI 7. 3. FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL, UNLESS SPECIFICALLY DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER 4. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF ASSEMBLY IN ACCORDANCE WITH SECTION CBC 15052, EXCEPTION 2 S. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCEISEI 7, SECTION 262 6. ALL APPUCABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE 'DESIGN ASSUMPTIONS: 1. LEAST BUILDING WIDTH OF MAIN STRUCURE 30' 2. BUILDING HEIGHT OF MAIN STRUCTURE (MEAN ROOF HEIGHTS 20' MIN 3. MINIMUM COVER PROJECTION IS IV. 4. MINIMUM COVER SIZE ATTACHED TO MAIN STRUCTURE OR FREESTANDING: IV x 10' 5. MINIMUM ROOF SLOE FOR SOLID ROOF PANELS WITH DECK: SEE DETAIL iBIS32 6. MINIMUM ROOF SLOE FOR SOLID ROOF PANELS WITH DURAPANEL• SEE DETAIL 1AIS3.2 7. MINIMUM SIZE OF EXISTING ROOF OVERHANG IS 50 SQUARE FEET, WHERE COVER IS ATTACHED TO THE EXISTING OVERHANG. 8. THE RATIO (HIP), COVER MEAN ROOF HEIGHT (H, FT.) DIVIDED BY COVER PROJECTION OR WIDTH (P, FT), SHALL NOT EXCEED ONE (1)_ 9. THE RATIO (LIP), COVER LENGTH (L, FT.) DIVIDED BY THE COVER PROJECTION OR WIDTH (P, FT), SHALL NOT BE LESS THAN ONE (1). 10. THE'LENGTH OF STRUCTURE' SHALL BE TAKEN AS THE CONTINUOUS DISTANCE MEASURED ALONG THE EXISTING BUILDING WALL FROM ONE END OF PA110 COVER SUPPORT BEAM TO THE OTHER INCLUDING ANY BEAM SPLICES. THE STRUCTURE LENGTH SHALL BE DETERMINED THIS WAY REGARDLESS OF ROOF COVERING TYPE, INCLUDING COMBINATION ROOFS WITH BOTH TRELLIS AND DECK ROOF USED ON THE SAME CONTINUOUS PATIO COVER STRUCTURE. HOWEVER OPEN LATTICE PORTIONS OF THE STRUCTURE SHALL NOT BE COVERED BY ROOF DECK PER IAPMO 195. 11. PATIO COVERS WITH SOLAR PANELS ON THE ROOF. CONTACT DURALUM PRIOR TO ORDERING THE PART AND SU8MT1l1NG DRAWINGS TO LOCAL AUTHORITY HAVING JURISDICTION. 12. CALCULATIONS FOR MAXIMUM SPANS WHEN ATTACHING TO AN EXISTING ROOF OVERHANG, AS SHOWN ON TABLE 1 ON S6.1 AND/OR L6.1, ARE ASSUMING THAT THE EXISTING E WOOD RAFTERS OR TRUSSES ADOUGLAS FIR -LARCH ND2. THIS TABLE CAN ALSO BE USED FOR OTHER WOOD SPECIES WITH Fb z 900 psi AND Fv 2180 psi. GENERAL NOTES DRAWING NOTES: 1. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED; AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 2. THE APPROVED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE JOB SITE AND SHALL BE AVAILABLE TO THE AUTHORIZED REPRESENTATIVES OF THE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE ORDER MATERIAL SPECIFICATIONS: 1. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL OR GREATER YEILD AND ULTIMATE STRENGTHS 2. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF2,SDO POUNDS PER SQUARE INCH. 3. EMBEDDED STEEL MEMBERS SHALL BE HOT -DIPPED GALVANIZED, AND CONFORM TO A500 GRADE B. ROLL FORMED STEEL MEMBERS SHALL CONFORM TO A653 -SS (STRUCTURAL STEEL) GRADE 50 G60. 4. BOLTS: ALUMINUM BOLTS SHALL BE 202474; STEEL BOLTS SHALL BE ASTM A-307. ALL BOLTS SHALL HAVE STANDARD -CUT PLATED WASHERS. 5. SCREWS: ALL SCREWS ARE SELF DRILLING (SDS) OR SHEET METAL SCREWS (SMS) IN CONFORMANCE WITH ICC -ES ESR 1976, ICC -ESR 3006, OR APPROVED EQUAL 6. FASTENERS TO WOOD: WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION. 7. POST -INSTALLED ANCHORS: POST4NSTALLED ANCHORS USED SHALL BE SIMPSON STRONG TIE STRONG BOLT 2, STAINLESS STEEL (ICC -ESR 3037) OR EQUAL. B. ALL COMPONENTS MANUFACTURED OR SUPPLIED BY DURALUM AND DESCRIBED IN THIS DOCUMENTS ARE INTERCHANGEABLE, PROVIDED THEY ARE SELECTED APPROPRIATELY TO SUPPORT THE LOADING THEY ARE SUBJECT TO. 9. THE SELF WEJGHT OF THE PATIO COVER COMPONENTS IN THIS REPORT CAN BE CALCULATED FROM THEIR SECTION PROPERTIES. THE SOLID COVERS VARY. IN WEIGHT FROM ABOUT 1 PSF TO ABOUT 3 PSF. 10. ROOF INSULATED PANELS (WHERE OCCURS} SEE S32 FOOTINGS: 1. ALL NEW CONCRETE FOOTINGS SHALL BEAR ON FIRM, NATURAL,; UNDISTURBED SOIL OR CERTIFIED FILL 2 DESIGN VERTICAL SOIL BEARING PRESSURE IS 500 POUNDS PER SQUARE FOOT. 3. DESIGN LATERAL SOIL BEARING PRESSURE IS 200 POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS 1 DO PSFIFT x 2 PER TABLE 18062 AND SECTION 18063.4), 4. ATTACHED COVERS FOR RESIDENTIAL USE MAY BE SECURED TO AN EXISTING CONCRETE SLAB PROVIDED THE SLAB IS AT LEAST 3112 INCHES THICK AND IS LOCATED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. THE SLAB SHALL BE A MINIMUM 10.0' WIDE BY THE MAXIMUM COLUMN SPACING MEASURED AT THE COLUMN AND SHALL NOT CONTAIN ANY CRACKING FOR SNOW LOADS OF 25 PSF AND ABOVE THE DISTANCE FROM COLUMN TO SLAB EDGE SHALL BE 6' MINIMUM. 5. A MAXIMUM COLUMN LOAD OF 750 POUNDS IS PERMITTED FOR ATTACHED COVER COLUMNS BEARING ON EXISTING OR NEW CONCRETE SLABS. NOTES TO LOCAL AUTHORITY HAVING JURISDICTION AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL USE OF THIS SET OF PLANS FOR A SITE SPECIFIC PROJECT: 1.. EACH PROJECT SUBMITTED TO THE LOCAL AUTHORITY HAVING JURISDICTION MAY INCLUDE ONLY THE PERTINENT SITE-SPECIFIC STRUCTURAL COMPONENTS : LOCATED WITHIN THIS IAPMO-LISTED EVALUATION REPORT. 2` ALL ITEMS PERTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEL, HEADER SPAN, COLUMN SIZE, ETC.) SHALL BE CIRCLED AND CLEARLY IDENTIFIED. 3. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG INDICATING THE NAME AND ADDRESS OF THE MANUFACTURER DESIGN LOADS AND ENCLOSABIUTY. 4. A WET STAMP FROM 4STEL ENGINEERING IS NOT REQUIRED ON THOSE PAGES FROM THE IAPMO REPORT. 5. A COLOR COPY OF THOSE PAGES FROM THE IAPMO REPORT IS NOT REQUIRED. I ATA MINIMUM. SUBMISSION FOR A BUILDING PERMIT MUST INCLUDE THE FOLLOWING INFORMATION FROM THIS EVALUATION REPORT 1. TITLE SHEET AND GENERAL NOTES, GOA 2. STRUCTURAL CONFIGURATION (Le. SOLID OR LATTICE ROOF, FREESTANDING OR ATTACHED). Six OR Ll x 3. BASED ON THE REQUIRED DESIGN LOADS, SITE-SPECIFIC RAFTER ANDIOR PANEL SPAN TABLES. 4. TYPE OF HEADER, POST TYPE 8 QUANTITY, FOOTING SIZE (WHERE REQUIRED) BASED ON THE SITE-SPECIFIC DESIGN LOADS. 5. APPROPRIATE STRUCTURAL DETAILS. 6. OTHER DOCUMENTATION THAT MAY BE REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 7. SEE S1x OR L1x FOR SHEET INDEX JOB NAME: JOB ADDRESS: P ' WIND LOAD: LIVE I SNOW LOAD: SEE SHEET Six OR Llx FOR SHEET INDEX ALL UNUSED SHEETS SHALL BE REMOVED FROM THIS SET OF DRAWINGS. 1 f SHEET INDEX Lifetime Patios PO Box 5806 La Quiata, CA 92248 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESSI S 5885 ry T�tP ��P lF OF DAl1ECR DATE SIGNED: April 5, 2017 // I %CL_ E/VVJ/�FE�"i�JJ4JG. 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AH.) APPROVAL REVISIONS FMAR,K DATE DESCRIPTION L JOB 9 16.1071 DATE 000517 DRAWN BY RER CHECKED MDS IAPM0195' V 2.0 TITLE SHEET, DESIGN LOADS, GENERAL NOTES i x m (E) BUILDING .................................................... BEAM CLEAR LENGTH 'L' SEE NOTE 1 PLAN VIEW NOTES: 1. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' 'SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLD COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'FT (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACEM CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLD COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIS (Bext)= if ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT •TRIS (BLDG)=h ADJACENT DECK CLEAR SPAN 2. SOLD COVERS A SEE SHEET SlIA FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOLD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLD COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2&S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. 3. BEAMS SOLD ROOF PANEL SEE NOTE 2 04E SfE N0� 2 SL LCONCRETE FFG, SEE NOTE 5, TYP 1 B ISOMETRIC VIEW 3/32"=1'-0• A SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE STI FOR ALTERNATE FOOTING SIZES. D. SEE 8/S7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED 16.1071 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) D41OW17 DRAWN BY SOLID COVER CONNECTION CHECKED WIND SPEED AND EXPOSURE I ! TO BLDG SEE' NOTE! 2 110B 110C 12081200 1305 130C 2 w � a rw- vwi I I I i � I I I I •: �n o z RTRLB ! 3 3 4 w N 4 I I 1 COL, TYP U � 4 ! I I I SEE NOTE A 1 I I o 0 o w W (n ! I SOLD COVER CONNECTION I TO BEAM SEE: NOTE 2 I I I 5 3 4 4 5 5 6 11' BEAM CLEAR LENGTH 'L' SEE NOTE 1 PLAN VIEW NOTES: 1. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' 'SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLD COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'FT (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACEM CLEAR SPAN. EXCEPTION= NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF BOTH DECK & IRP SOLD COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIS (Bext)= if ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT •TRIS (BLDG)=h ADJACENT DECK CLEAR SPAN 2. SOLD COVERS A SEE SHEET SlIA FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.1 FOR REDUCTION OF SOLD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLD COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2&S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. 3. BEAMS SOLD ROOF PANEL SEE NOTE 2 04E SfE N0� 2 SL LCONCRETE FFG, SEE NOTE 5, TYP 1 B ISOMETRIC VIEW 3/32"=1'-0• A SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE AN INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR COLUMN. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS S7.1 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEET S7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE STI FOR ALTERNATE FOOTING SIZES. D. SEE 8/S7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED -'•'F ,sem. t - NOTES: \ 61SN6MBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD q d' POSTS AS REQUIRED TO ENSURE THAT THE -MAX POST SPACING E-� (SPANT SHOWN. ON SHEETS SBxx.x OR LB.xx.x IS NOT E)CEEDED. .!< z THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAL 356.3 `. nPR34b.3. . 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES ANDTHE BEAM IS CONNECTEDTO THE COLUMN DIRECTLY OR WRH A BRACKET PER S6.3 OR L6.3. A TABLE 1 - MINIMUM NUMBER OF COL REQ. SHEET INDEX - SOLID PANEL STRUCTURES: TYPE A GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S1.1 - SOLID PANEL STRUCTURES: TYPE A S2.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1A=SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2 - SOLID PANEL STRUCTURES: CROSS SECTION S4.1 - SOLID PANEL STRUCTURES: BEAM PROFILES S42 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4 - SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5 - SOLID PANEL STRUCTURES: CONNECTORS S5.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S62 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S72 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S8.1DLX - SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1 X MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS Flo 0OR ZOE Oil 1 SOLID PANEL STRUCTURE TYPE A: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER n w -moi 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 r-1,14411 tl K � W 4 S 5885 M / i i OF CAS - DATE SIGNED: April 5, 2017 ;Lk)WV/TC<_ GllE�E�f�//'t��s 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 IAHJAPPROVAL I REVISIONS I MARK DATE DESCRIPTION 4 STEL JOB # 16.1071 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) D41OW17 DRAWN BY RER CHECKED WIND SPEED AND EXPOSURE 110B 110C 12081200 1305 130C 2 2 2 3 3 3 2 33 3 3 4 RTRLB 2 3 3 4 3 4 3 3 3 4 4 3 4 4 4 4 5 3 4 4 5 5 6 11' 4 4 4 5 5 6 1T 4 s 5 6 5 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIg WIND SPEED AND EJPOSUR WIDTH k -110 -B -T 11DC 120B 1200 13DB 13DC S 2 22 2 2 3 6 2 2 2 3 3 3 T 2 3 3 3 3 4 8 2 3 3 4 3 4 T7 3 3 3 4 4 5 10 3 4 4 4 4 5 11' 3 4 4 5 3 6 17---- _..3 d 4 5 5 5 -'•'F ,sem. t - NOTES: \ 61SN6MBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD q d' POSTS AS REQUIRED TO ENSURE THAT THE -MAX POST SPACING E-� (SPANT SHOWN. ON SHEETS SBxx.x OR LB.xx.x IS NOT E)CEEDED. .!< z THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAL 356.3 `. nPR34b.3. . 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES ANDTHE BEAM IS CONNECTEDTO THE COLUMN DIRECTLY OR WRH A BRACKET PER S6.3 OR L6.3. A TABLE 1 - MINIMUM NUMBER OF COL REQ. SHEET INDEX - SOLID PANEL STRUCTURES: TYPE A GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S1.1 - SOLID PANEL STRUCTURES: TYPE A S2.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1A=SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2 - SOLID PANEL STRUCTURES: CROSS SECTION S4.1 - SOLID PANEL STRUCTURES: BEAM PROFILES S42 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4 - SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5 - SOLID PANEL STRUCTURES: CONNECTORS S5.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S62 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S72 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S8.1DLX - SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1 X MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS Flo 0OR ZOE Oil 1 SOLID PANEL STRUCTURE TYPE A: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER n w -moi 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 r-1,14411 tl K � W 4 S 5885 M / i i OF CAS - DATE SIGNED: April 5, 2017 ;Lk)WV/TC<_ GllE�E�f�//'t��s 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 IAHJAPPROVAL I REVISIONS I MARK DATE DESCRIPTION 4 STEL JOB # 16.1071 DATE D41OW17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 SOLID PANEL STRUCTURES: TYPE A S1.1 I 9 � m o �m w 'u N m � O m z w N NOTES: . I. PATIO COVER. DIMENSIONS _ A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION V. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLD COVERS AND LATTICE FRAMING. B. HEIGHT Of STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN, OR 24° MAX E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF LATTICE'S ADJACENT SPAN, OR 24° MAX. F.' TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: TRIG (Bext)= YZ ADJACENT DECK CLEAR SPAN @7RIGHit + DECK OH @ LEFT • TRIS (BLDG)=7¢ ADJACENT DECK CLEAR SPAN 2. LATTICE' COVERS A SEE SHEET L4.1 FOR LATiiCE PROFILES. ' B. SEE SHEETS L3.1A k 13.1E FOR RAFTER PROFILES LENGTH 'L' SEE NOTE 1 PLAN VIEW~? v 1/16•=1'-0° AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION Of RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. / 0 1 ISOMETRIC VIEW s/3z'=1'-0' 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFlLES. B. SEE SHEETS U.1 & LBxx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS &DETAILS. 4 COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. + B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND LB.zx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x k L7.x FOR COLUMN CONNECTIONS &DETAILS. 5. FOUNDATIONS B A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS Lb.xz.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED:, C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/L7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. 0 z W 2 2 TABLE 1 _ MINIMUM NUMBER OF POSTS REQUIRED (E) BUILDING ~- WITH 2 z 6.5 x Q032 SIDE PLATES (SIDE PLATE TYPE SP3) I RAFTER CONNEC)lON TRIG • TO BLDG SEE NOTE 2! WIDTH 1108 1100 1208 1200 1308 LATTICE q 3" PR 6": O.C. i 5 2 SEFT NOTE 2 I I 3 3 6 2 EDGE COL ! 3 4 T i I SES NOTE 4 t ' 3 3 4 3 4 • 3 1 I ! ! I � 1 ! I ! i ! � RAFTER CONNECJION I I BEAM SEE NOT 3 ! ! 4 5 ! TO BEAM SEE NOTE i ! 3 a 4 4 BEAM OH I BEAM CLEAR SPAN BEAM CLEAR SPAN 9 � m o �m w 'u N m � O m z w N NOTES: . I. PATIO COVER. DIMENSIONS _ A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION V. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLD COVERS AND LATTICE FRAMING. B. HEIGHT Of STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN, OR 24° MAX E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF LATTICE'S ADJACENT SPAN, OR 24° MAX. F.' TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: TRIG (Bext)= YZ ADJACENT DECK CLEAR SPAN @7RIGHit + DECK OH @ LEFT • TRIS (BLDG)=7¢ ADJACENT DECK CLEAR SPAN 2. LATTICE' COVERS A SEE SHEET L4.1 FOR LATiiCE PROFILES. ' B. SEE SHEETS L3.1A k 13.1E FOR RAFTER PROFILES LENGTH 'L' SEE NOTE 1 PLAN VIEW~? v 1/16•=1'-0° AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION Of RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. / 0 1 ISOMETRIC VIEW s/3z'=1'-0' 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFlLES. B. SEE SHEETS U.1 & LBxx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS &DETAILS. 4 COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. + B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND LB.zx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x k L7.x FOR COLUMN CONNECTIONS &DETAILS. 5. FOUNDATIONS B A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS Lb.xz.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED:, C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/L7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. 0 z W 2 2 TABLE 1 _ MINIMUM NUMBER OF POSTS REQUIRED NOTES: 1. NUMBER OF POSTS SHOWN W THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE 'MAX POSTSPACING (SPANr SHOWN ON SHEETS SB.xxx OR LB.xxx IS NOT EXCEEDED. 2. THIS TABLE 670 BE USED IN CONJUNCTION WITH DETAIL 356.3 OR 3�L 6.3. 3. THIS TABLE DOES NOT APPLY ff THE SIDE PLATES ARE PROVIDED FOR AE57HETICAL PURPOSES AND THE BEAM 5 CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER 56.3 OR L6.3. TABLE 1 -MINIMUM NUMBER OF COL REQ SHEET INDEX - LATTICE STRUCTURES: TYPE E G0.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L1.1 -LATTICE STRUCTURES: TYPE E L21 -LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFTAND SLIDING L3.1A- LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PROFILES L42 -LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 -LATTICE STRUCTURES: ATTACHMENTTO EXISTING BUILDING L62 -LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS LBJocX - LATTiCE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PS LL15L,1X0 MPH y � G9.1-ADDiT10NAl STATE LICENSURE STAMPS -LATTICE COVER STRUCTURE TYPE E: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER :ate 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Iq�� w � S5885 ryTF OF CA,���� DATE SIGNED: April 5, 2017 S 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AWAPPROVAL REVISIONS MARK DATE DESCRIPTION a sTe. JOB # 161071 DATE 04105/17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: TYPE E L1.1 I WITH 2 z 6.5 x Q032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIND SPEED AND EXPOSURE WIDTH 1108 1100 1208 1200 1308 130C 5 2 2 2 3 3 3 6 2 3 3 3 3 4 T 2 3 3 4 3 4 B' 3 3 3 4 4 5 4 3 a 4 4 4 5 1D 3 4 4 5 5 6 11' 4 4 4 5 5 6 1z a s s 6 s r WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SPO) TRIB WIND SPEED AND EJPO.SURE WIDTH 1108 1100 1206 120C 1308 1300 5 2 2 2 2 2 3 6 2 2 2 3 3 3 T 2 3 3 3 3 4 B 2 3 3 4 3 14 4 3 3 3 4 4 's 1D 3 4 4 4 4 5 71' 3 4 4 5 5 6 17 3 a 4 5 s 5 NOTES: 1. NUMBER OF POSTS SHOWN W THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE 'MAX POSTSPACING (SPANr SHOWN ON SHEETS SB.xxx OR LB.xxx IS NOT EXCEEDED. 2. THIS TABLE 670 BE USED IN CONJUNCTION WITH DETAIL 356.3 OR 3�L 6.3. 3. THIS TABLE DOES NOT APPLY ff THE SIDE PLATES ARE PROVIDED FOR AE57HETICAL PURPOSES AND THE BEAM 5 CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER 56.3 OR L6.3. TABLE 1 -MINIMUM NUMBER OF COL REQ SHEET INDEX - LATTICE STRUCTURES: TYPE E G0.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L1.1 -LATTICE STRUCTURES: TYPE E L21 -LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFTAND SLIDING L3.1A- LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PROFILES L42 -LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 -LATTICE STRUCTURES: ATTACHMENTTO EXISTING BUILDING L62 -LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS LBJocX - LATTiCE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PS LL15L,1X0 MPH y � G9.1-ADDiT10NAl STATE LICENSURE STAMPS -LATTICE COVER STRUCTURE TYPE E: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER :ate 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Iq�� w � S5885 ryTF OF CA,���� DATE SIGNED: April 5, 2017 S 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AWAPPROVAL REVISIONS MARK DATE DESCRIPTION a sTe. JOB # 161071 DATE 04105/17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: TYPE E L1.1 I m ` RAFTER w SEE NOTE 2 WITH 2 x 6.5 x 0.002 SIDE PLATES (SIDE PLATE TYPE SP3) (E) BUILDING TRIS i I I RAFTER CONNECTION - a CONCRETE SLAB, WIDTH I I I I TO BLDG SEE NOTE 2' I i W_ 1308 c S 2 2 2 3 3 3 6 Ix 3 3 3 3 4 T m Z I ! I ! I i -- H II w I I jLATTICE @ 3" OR 6. O.C. I a 5 9 SEE NOTE 2 I I I I i 4 4 4 4 5 _ I 3 4 4 5 5 EDGE COLI I L) m m w RAFTER CONNECTION SEE NOTE '4 m 17 o TO BEAM SEE NOTE 2' ' 5 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED AND EXPOSURE WIDTH 1108 110C 1208 1200 1308 A OH BEAM CLEAR SPAN BEAM CLEAR SPAN 2 2 2 a 40TE 1 I W 2 2 3 3 3 T LENGTH 'L' SEE NOTE 1 3 3 3 PLAN VIEW NOTES: 1. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE W (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN.. D. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB .(Bext)= Yt ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (Sint)= Yl ADJACENT DECK CLEAR SPAN @ RIGHT + 34 ADJACENT DECK CLEAR SPAN @ LEFT • TRIB (BLDG)=X ADJACENT DECK CLEAR SPAN 2. LATTICE COVERS A SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEETS L.3.tA & L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. ROOF OVERHANG OR WOOD, CONCRETE, BRICK MASONRY WALL SEE SHF. 8 RAFTER SEE NOTE 2---\ N- CONCRETE FTG, SEE NOTE 5, TYP B ISOMETRIC VIEW 3/32•=V -O' 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7.1 & LB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. I C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND L.B.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS: - 5. FOUNDATIONS A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. = B. SEE BEAM SPAN TABLES ON SHEETS L.B.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/0.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. - i Lu z w s C -5 s TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED SHEET INDEX - LATTICE STRUCTURES: TYPE F GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L7 2 - LATTICE STRUCTURES: TYPE F L.2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLmING L3.1A-LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L62 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 -LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8=X - LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1X0 MPH G9.1-ADDITIONALSTATE UCENSURE STAMPS LATTICE COVER STRUCTURE TYPE F: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER To- 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� w S.5885 rq QCT TF OF CAItF� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 = 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION F 4 STEL JOB # 161071 DATE 04105117 DRAWN BY RER CHECKED MDS 'IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE F L1.2 NOTES: WITH 2 x 6.5 x 0.002 SIDE PLATES (SIDE PLATE TYPE SP3) 1. NUMBER OF POSTS SHOWN W THIS TABLE IS A MINIMUM. ADD TRIS WIND SPEED AND EXPOSURE CONCRETE SLAB, WIDTH 110B 110C 1208 120C 1308 1300 S 2 2 2 3 3 3 6 2 3 3 3 3 4 T 2 3 3 4 3 4 8' 3 3 3 4 4 5 9 3 4 4 4 4 5 10 3 4 4 5 5 6 1t' 4 4 4 5 5 6 17 4 1 5 5 6 5 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED AND EXPOSURE WIDTH 1108 110C 1208 1200 1308 130C S 7 2 2 2 2 3 6 2 2 2 3 3 3 T 2 3 3 3 3 4 6 2 3 3 4 3 4 9 3 3 3 4 4 5 10 3 4 4 4 4 5 11' 3 4 4 6 4 3 __5__5 4 4 5 , 5 SHEET INDEX - LATTICE STRUCTURES: TYPE F GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L7 2 - LATTICE STRUCTURES: TYPE F L.2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLmING L3.1A-LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L62 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 -LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8=X - LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1X0 MPH G9.1-ADDITIONALSTATE UCENSURE STAMPS LATTICE COVER STRUCTURE TYPE F: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER To- 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� w S.5885 rq QCT TF OF CAItF� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 = 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION F 4 STEL JOB # 161071 DATE 04105117 DRAWN BY RER CHECKED MDS 'IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE F L1.2 NOTES: ' 1. NUMBER OF POSTS SHOWN W THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE'MAX POST SPACING (SPANT SHOWN ON SHEETS S8.xx.x OR LB.xxx IS NOT EXCEEDED. CONCRETE SLAB, SEE NOTE 5 2. THIS TABLE 1S TO BE USED IN CONJUNCTKNJ WITH DETAIL 31S6.3 OR YL6.3. J 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHET)CAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. TABLE 1 - MINIMUM A NUMBER OF COL REQ. SHEET INDEX - LATTICE STRUCTURES: TYPE F GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L7 2 - LATTICE STRUCTURES: TYPE F L.2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLmING L3.1A-LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L62 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 -LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8=X - LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1X0 MPH G9.1-ADDITIONALSTATE UCENSURE STAMPS LATTICE COVER STRUCTURE TYPE F: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER To- 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� w S.5885 rq QCT TF OF CAItF� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 = 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION F 4 STEL JOB # 161071 DATE 04105117 DRAWN BY RER CHECKED MDS 'IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE F L1.2 ALUM. ALLOY 30 1ALLIM. ALLOY 3DO4-H361 JALLIM. ALLOY 3004-H36 a T o T o N 0 0 10 `S c 2.000"? 2 000' 4.000" 3.000" l �. \ 3'x8' RAFTER RD r x 6b' RAFTER R3 DBL '2' x BE RAFTER 3x8 RAFTER. -ATTACHED STRUCTURE 2X612 RAFTER -ATTACHED STRUCTURE.DBL. 1 . 2612 RAFTER -ATTACHED STRUCTURE LL/SL T_. Q SPACING _ WIND SPEED / EXP O/C 110 B 110C 120 B 120 C 130 B 130 C LL/SL T (I SPACING O/C 110 B WIND SPEED / EXP 110C 120 B 120 C 130 B 130 C LLSL T ON) SPACING O/C 110 B WIND SPEED / EXP 110C 120 B 120.0 130 B 130 C 10 0.042 16' 29'-8' 25-6' 29'-8' 28=9' 2,73' 25-3' 10 0.024 16• 15-0' 15-10' 15-0' 15'-0' 15'-9' 13-6' 10 0.024 16• 2T-6' 27.4' 27-6' 21'4' 27-2' 19-2- 24* _ 24'-2' 24'-1' 24'-2' 23'-6' 24'-0' 21'-6' 24' 13'-1' 13'-0' 13'-1' 12-3' 12-10' 11'-2' 24' 18'-4' 18'3' 1B'i' 17-3' 18-2' 15'-0' 20 0.042 16' 23'-0' 23-0' 23'-0' 23=0' 23'-0' 27-9' 0.032 16' 211-3' 211-2' 211-3' 19'-8' 211-1' 18'-2'' 0.032 16' 28-T 29-6" 28'-7' 2T-9' . 28-3' 25'-7' 24' 18-9' 18-9' 18'-9' 18=9' 1B'-9' 18'-9' 24' 15-7' 15-6' 15-7' 16'-1' 19-4' 14'-10' 25 0.042 t6' 19'-8' 17-8' 15-8' 19'-8' 19'3' 19-8' 24' 23-4' 23'-3' 23'4' 27-6' 23-1" 211-10' 0.042 16' 24'-6' 24'-4' 24'-0' 23-9' 24'-3' 23-2' 0.042 16' 34'-7' 34'4' 34'-7' 33'-7' 34'-2' 37-8.' 24' 15-1- 15-1' 15-1- 16-1' 15-1- 15-1' 24' 211-1' 2a4r 211-1' 19'-6' 19'-9' 14-0' 24' 25-2' 28-1' 25-2' 27-4' 2T-10' 26'-8- 30 0.042 15 15-1' 18-1' 16-1' 161' 1B-1'1 18-1' 20 0.024 16' 17.4' 174' 174- 174' 17-4' 174' 20 0.024 16' 1T4' 1T4' 1T4' Ir -4' 17-4' 1T3- 24- 13'-9' 13'-9' 13'-9' 13 9' 13'-9' 13'-9' 24" 10'-2' 111-2' 111-2' to -2' 10'-2' to -1' 24' 14'-2' 14'-2' 14'-2' 14'-2' 14-2* 14'-2° 40 0.042 16' 15-10' 15'-10` 1S-10' 15-10' 15'-10' 15-10' 0.032 16' 15'-8' 15-8' 151-0' 15-8' 15'4' 15-8' 24' 0.032 16' 27-1' 27-1' 27-1' 27-1' 27-1' 27-0' 24' 17-1' 17-1' 17-1' 17-1' 17-1' 17-1' 50 0.042 16' 134' 13'4' 13'4.' 13'-4' 13'4' 134' 17-10' 17-10' 17-10' 17-10' 17-10' 17-9' 24' 15-1` 15-1' 18-1' 15-1' 18-1' 15-0' 0.042 16' 19'-0' 19'-0' 19-0' 19'-0' 1T -O' 1 0.042 110' 16' 25-8' 26'4r 25-8' 25-8' 26-8' 25-7' 24' 111-3' 111-3' to -3' 111-3' 111-3' to -3' 24' 15-6' 15-6' 15'-6' 15'-6' 15-6' 15-6' 24' 21'40' 21'-10' 31'-10' 21=10' 21'-10' 21'-9' / NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: (2) 3x8 Q 32'OC IN LIEU OF (1) 3x8 @ 16'OC (2) 3x8 Q 48 -OC IN LIEU OF (1) 3x8 @ 24 -OC - (2) 2x619 32' OC IN LIEU OF (1) 2x6 @ 16'OC - (2) 2x6 0 48 -OC IN LIEU OF (1) 2x6 Q.24'OC % ( - 25 0.024 16' 111-7- 111-7' 111-7' 1174' 111-T 111-T' 25 6.024 16' 15'-10' 15'-10' 151-1D' 16-10' 15'-10' 15'-10' 24' S-1' 8'-1' 8'-1' 8'-1' 8'-1' 8,-1' 24' 13'-4' 134' 134' 13'-2' 13-3' 17-9' 0.032 16' 144' 14'4' 144' 14'4' 14'-4' 14'-4' 0.032 16' 211-2' 311-2' 27-2"211-2' 211-2' 211-2' 24' 11'-1' 11'-1' 11-1' 11'-1' 11'-1' 11'-1` 24' 19-7' 15-T 15-7' 15-7' 15-7' 15-7' 0.002 16' 1T•4' 1T-4' 1T4' 174' 1T4' 1T4' 0.042 16' 24'-0' 2C-0 24'-6' 24'-6' 24'-6' 24'-6' 24' 13'-3' 13-3' 13'3' 13'-3' 13'-3' 13'-3' 24 211-0' 217-0." 2(Y -O' 211-0' 20-0' 211-0' 30 0.024 16' 29'-8' 29'-6' 29'4- 28'-9' 29'-3' 25-3' ' 0.024 16' 15=0' 15-10' 15-0' 15-0' 16-91 13'-0' 24' 24-2' 24'-1' 24'-2' 23'-6' 24'-0' 21'-6' 24' 13'-1' 13'-0' 13'-1' 17-3' 17-10' 11'-2' 0.032 16' 23'-0` 23'-0' 23'-0' 23'-0' 23'-0' 2Z-9- 16' 211-3' 20-2' 211-3' 14-6' 20-1" 15-2' 24' 18'-9' 15-9' 18'-9' 18'-9' 18'-9' 18'-9'230 4' 24' 16'-T 1 16'-0' 16'-7' 16'-1' 10-4' 14'-10' 0.042 16• 19`-8' 1948' 19-0' 19-8' 1744 19'-8' 0.042 16' 2V-6' 24'-4' 24'-6' 23'-9' 24'-3' 23-2' 24' 15-1' 15-1' 1E-1' 16'-1' 15-1' 15-1' 24' 22-1' 20'-0' 211-1' 19'-6' 14-9' 19.0- 40 0.024 16' 1Q-1' 18=1' 18'-1- 18'-1' 15-1' 18'-1' 40 0.024 16' 174' 174' 17.4' 174' 174' 174' 24' 13'-9" 13'-9' 13-4' 13-9' 13-9' 13-9' 24' 111-2' 10-2' 111-2' 1117-2' 10-2" 111-t' 0.03224' 16' 15-10' 15-10' 15-10' 15'-10' 15-10' 11 51-111' 0.032 16' 15'-8' 151-0' 15'-8' 15-8' 15-8" 151-0' 17-1' 17-1' 17-1' 17-' 17-1' 17-1' 24' 17-10' 17-10' 17-10' 17-10' 17-10' 17-9' 0.042 16• 13'-4' 13'4.• 13'-4' 13'4' 13'4' 13'-4' 0.042 16' 19'-0' 19'-0' 19'-0' 19'-0' 19-0' 18'-10• 24' 111-3' 111-3' 10'-3' 10'3' 111-3' 111-3' 24' 15'-6' 15'46' 15'-6' 15'-6• 19-6' 15'-0' 50 0.024 16' 18'-1' 18'-1' 15-1' 18'=1' 15-1' 15-1' 510 0.024 16' 111-T 111-7' 10'-T" 111-7- 111-T 111-T 24' 13'-9.' 13'-9' 13'=9' 13'-9' 13'-9' 13'-9' 24' 8'-1' S-1' 9-1' 8`-1' 8'-1' 8-1' 0.032 16' 15'-10' 15-10' 15'-10' 15'-10' 16-10' 16-10' 0.032 16' 14'-4' 14'-4' 14'•4' 14'4' 14'4' W4' 24' 17-1' 12-1- 17-1' 17-1• 17-1' 17-1' 24.1".11'-1' 11'-1' IVA" 1T-1' 11'-1' 0.042 16' 13'-4' I. 134' 13.4' 134' 134" 0.042 17' 16' 4' 1T4- 174' 1T4' 174' 174' 24' 1113- 1 a-3' 1113' 111-3' la -3' 19-3*- 24' 13'-3' 13'3' 13-3' 13'-3' 13-3' 13'3' r.; tij 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� �xl_ K �E92 w S5885 m JF OF �t�F� l DATE SIGNED: April 5, 2017 Chl"A i- 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AW APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB >I 161071 DATE 005117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L3. 1 A J 1 ( T o' o J m 3.000" I w„ 13' x 8' RAFTER n� 3"=1-0" l ALUM. ALLOY 3OD4-H361 IALUM. ALLAY 3004-H35 T 2.000" R2 - .7x8.5' RAFTER _i L " ALUM. ALLOY 3004-H36 T o 2.000' 4.000" 2.000" MAX I DBL Z x 8.5 RAFTER , 3x8 RAFTER- FREESTANDING STRUCTURE 2X6 12 RAFTER.- FREESTANDING STRUCTURE DBL. 2X612 RAFTER- FREESTANDING STRUCTURE LUSL T Q SPACING WIND SPEED / EW LUSL T SPACING O/C 1108 WIND SPEED / EXP 110 C 120B 120 C 130 B 130 C LLISL T ON) SPACING O/C 110 B WIND SPEED / EXP 110 C 120 B 120 C 130 B 130 C O/C 110B 110C 120 B 120 C 130 B 130 C 10 0.042 16 29-3' 26-3' 25-3' 26=3" 26'-3' 26-7- 10 0.024' 16'_ 14'-2' 14'-Y 14'-2' 14'-2' 14`-2' - 10 0.024 16' 19'-10' 19-10'19'-10' 1410' 19'-10' 144' -0 -0 24' 21'' 21'-6' 21'-V 21'-6' 21'' 21'-0' _IT_9' 24'! 11'-T 11"-T' 11'-7' 11'-7' 11'-7' 11'-3' 24' 19-3' 193' 19-3' 19-3' 19-3' 15'-10' 20 0042 16' 21'-10' 21'-10' 21=10'2V-10" 21'-10' 21'-10' 0.032 16' 18'-0' IW -0' 18'-0' 18'-0' 18'-0' :1T-77. 0.032 16' 25-3' 25'-3' 25'-3' 25-3' 25-3' 24'-8' 24' 1T-10' 1T-10' 17-10' 1T-10- 1T-10' 1T-10' 24' 14'-8` 14'-B' 14'-8' 14'-B' 14'48' 14'-4' 24' 20'48' 20'-8' 20'-8' 20'-8' 20-8' 2U-2- 25 25 0.043 21'-6' 21'-6' 21'-6" 21-2' 21'-3' 217-8 0.042 16` 21`-9` 21'-9' 21'-9' 21'-9' 21'-9' 21'-2' 0.042 16' 317-8' 317.8' 317-8' 30'-8' 30-8' 29'-10' 24' 1T-7" 1T-7' 1T -T' 1T4' 1T 6' 19-10' 24' 1T-9' 17-9' 1T-9' 1T-9' 1T-9' 1T-3'' 24' 25-1' 25-1' 25'-1' 25-1' 23-1' 24'4' 30 0.042 16' 19-1' 14-1' 19-1' 191' 19-1' 19-1' 20 0.024 16' 11'-9' 11'-9' 11'-9' f1'-9' 11'-9' 11'-9' 217 0.024 16' 19-T 19-7' 19-7' 19-7' 19-T 19-7' . 24' 15'-r 1 S-7' 164" 1ST' 15-7' 15-7' 24' g$" 9,-0" g$" 9-8" 9'-0" T-8' 24' 13'-T 13'-7' 13-7' 13'-7' 13-T 13'-7' 40 0.042 1W 1Q-0" 19-8' 19-8' 19-8' 19-0' 19-8' 0.032 -16' 15-0' 15-0' 7S-0' 1S-0' 15'-0• 15-0' 0.032 16' 21'-1' 21'-1' 21'-1' 21'-1' 2T-1' 21'-1' 24" 13-0• 13-8' 13'4r 13-8' 13-0' 13-8' 24° 12-3' 12'-3' 17-3' IZ-3" 17-3' 17-3' 24' 1T-3' 1T3' 1T-3' 1T-3' 17-3' 1T3' 50 0.042 16' 1S-0- 15-0- 15-0' 1S-0- 1S-0- 15'-0' 0.042O.D42 16' 18'-1' 18'-1' 18'-1' 18'-1' 18'-1' 18'=1' 16' 25-6' 25'-0' 25-6' 25-6' 23-6' 25-6' 24' 11'-2' 11'-2- 11'-2' 11=2' 11'-2' 11'-2' 24' 14'-9- 14'-9' 14'-9' 14'-9' 14'-9' 14`-9' 24' 20'-1 Cr 217-1 U' 217-10' 20=10' 27-10' 217-10- - NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: (2) 3x8 32 -OC IN LIEU OF (1) 3x8 16 -OC (2) 3x8 (ag 48 -OC IN LIEU OF (1) 3x8 (q 24 -OC OF (1) 2x6 @ 1OC (2) 2x6 (d/ 32"OC IN LIEU W' (2) 2x6 48'OC IN LIEU OF (1) 2x6 (d124'OC ~ a 25, 0.024 16' 11'-7' 11'-7' 11'-7' 11'-6' 11'-6' 11'-Y 25 0.024 16' 1W-3' 193' 19-3' 19-1' 19-2' 1S4' 24' 9'-6' 94' 7-6' 9'-6' V-6' 9-2' 24' F 43" 9'-3' 9-3" 4-3' 9'3' Y -3 - 0.032 is" 14'-9' 14'-9' 14'-9' 14'-6' 14'-T 14'-2' 0.032 is, W-9' 217-9' 20'-9' 20'-6" 217-7' 19'-10' 24' 17-1" 1Z-1' 12-1' 11'-10' 1740' 11'-T 24' 1T40" 1T-0' 1T-0" 16'-6 19-9' 1W3 - 0.042 16' 17-9' 1T-9' 1T-9" 1T-7' 1T-8" 1T-1' 0042 16' 2S-1' 25'-1" 26-1' 25-1' 23-1' 25'-1' 24' 14'-7' 14'-7' 14'-7' 14'-4') 14'-6' 14'-0' 24' 217-6' 217.6' 20'-6' 217-6' 20-6' 217-6' 30 0.024 16' 29-3' 29-3' 2W3' 2W 3 -3' 26'' 2Q-7' 30 0.024 16" 14'-Y 14'-2' 14'-2' 14'-Y 1-f-2' - 139' 24' 21'-6' 21'-6' 21'-6' 21'-6 -621'' 21'-V 24' 11-T 11'-7' 11'-T' 11'-7' 1T-7' 11'-3' O.Q32 16" 21'-10' 21'-10' 21'-10' 21'-10' 2T-10' 21'-10' 0.032 16" 1944 19-0' 1W -D' 18'-0' 16-0' 1T-7' 24' 1T-10' 1T-10' 1T i0' 1i'-10' •tT-10' 1T-10' 24' 14'-8` 14'x' 14'-8' 14'-8' 14'-8" 144' 0.042 16' 21'-6'' 21'-6' 21'-6' 21'-Y 2V-3' 217-8' 0.042 16' 21'-9' 21'-9' 21'-9' 21'-9' 2T-9' 2T-2' 24' 17'-7- 17-7- 17-7' 1T.4'. 1T-6' 1W-10" 1 24' 1T-9' 1T-9' 1T-9' 1T-9' 1T-9' 1T3' 40 0.024 1.6' 19'-1' 19'-1' 19-1' 17-1' 19'-1' 19'-i' 40 0X24 16• 11'-9' 11'-9' 11'-9' 11'-9' 1T-9' 11'-9' 24' 1.7-7` 15-T 1S -T 15-7' 1S -T 1S -T' 24' 4-8' 9'-8" 9'-8' 48' 8'-0' 4-8' 0.032 16" 19-8' IV -8" 19-0' 16'-S* 'I W-8' 1 W-8' 0.032 16' 1S-0' 15!-0* 1.5'-0' 16-V 154' 16-07 24' 13-8' 13-8' 13'8' 13'-0' ; 13'-8' 13-8' 24' 123' 123' 1Z-3- 12-3' 12-3' 173- 0.042 16" 15-0' w-0' 1S-0` 1S-0' 15'-0' 15'-0` 0 42 16' 18'-'1' 1W-1' 18'-1' 1W-1' 19-1' 18'-1' 24' 11-2' 11'-2' 11'-2' 11'-2' 11'-2' 11'-2' 24' 14'-9' 14'-9" 14'-9' 14'-9' 14-9' 14'-9' 50 0.024 16' 19-1' 19'-1' 19-1' 19'-1' 19'-1' 14-Y 50 0.024 16' 1 T -T 11'-7.' 11'-T 1 T-6' 1 T-6' ii' -2- 24' 15'-T 1 S -T 15'-T 1 S -T 15 T 1 S -T 0.032 16' 1W-8' 16-8' 1 1W-8' I 16 8' 16!-W 19-8' 0.032 16' 14'-9' 14'-9' 14'-9' 14'-6' 14'-T 14'-2' 24' 13-8' 13-8' 13'-W 13'-0' 13-8' 113'-8' 24' 12'-1' 17-1' 12'-1' 11-10' 12-0' 11'-7' 0.042 16' 15'-0' 15'-0' 1 S-0' 15'-0' 15'-0' iv -o' 0.042 16' 0%9' 1 T-9' 1r-9, 17'-T 17-8' 1r-1, 24' Il Vr- 1 11'-2' I T-2' 1 11'-2' 11'-2' 11.'-2' 24' 14'-T' 14'-7' 14'-7' 14'4' 14'-6' 14'-0' I -- 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 - ESSIq,�� W S5885 - or TF OF CAL\F� DATE SIGNED: April 5, 2017 �I�G/M�'E6�II�Es 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MAW DATE DESCRIPTION 4 STEL JOB S 16-1071 DATE 04105117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FREESTANDING COVERS . RAFTER SPANS _ _Ll 1-F---.-- ALUM. ALLOY 3004406 3.000' 0 0 N LATTICE TUBE 6'=1'-0' ALUM. ALLOY 3004.136 0 0 0 0.018' ,C> 0 1.500' OR 2000° 1-1/2' SQ OR 2'SQ LATTICE TUBE 6°=1'i ALUM. ALLOY 3OD4-H36 1.229' STEEL ASTM A653 -SS, GRADE 50 G60I r 3' SQ x 0.032' ALUM. BEAM W/- 12 GA STL INSERT 3"=r-0° NUOUS . INSERT ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 Oil ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/- TYP. 0 i cd 3.000° 4.000° 3:000' MAX. DBL 3'80, x 0.042 ALUM. BEAM W/ 14 GA STL INSERT 3°=1'-0' ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 G60 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/- TYP. 0 3.000' 4.000" 1 3.000' m 7 c 0 co 3.00D' e2' 3x8x0.042' ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 0.042° , TYR O co 3.000" 4.000' 3.000° MAX 612 DBL 3 x 8 x0.042' 3°=1'-0" 0 C, 0.042' N N O 2.824° 3.000' ALUM. ALLOY 3004-H36 1�9. STEEL ASTM A653 -SS GRADE 50 G60 14 GA CONTINUOUS STEEL INSERT ALUM. ALLOY 3004-H36 2908' 0 c � o N pj 3.000' 3' SQ x OA32' ALUM BEAM W/- 12 GA STL 'U' CHANNEL ALUM. ALLOY 3004-H36 0.042' o0 TYP. v� 2.000' 4.000" 2.000' MAX DBL 2 x 6 x 0.042' B� 3°=1'-0' / B16 l DBL 3 SQ x 0.042 ALUM. BEAM �Q/ 13 l 3' SQ x 0.032' ALUM. BEAM W/- .. W/ 12 GA STL INSERT 3"=1' D' ��'J 14 GA STL INSERT3•=(Bl ALUM. ALLOY 3004-H36 0.032°TYP. 2.000" 4.000° 2.000' DBL2x6x0.032' s - 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS I W S5885 � Y F' r�lF OF CALVE DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB A 161071 DATE 0410SM7 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: BEAM PROFILES L4. 1 �-- ASTM A500 GRADE 8 ASTM A500 GRADE Li JALUM.. ALLOY 3004-56 JALLIM. ALLOY 3004-1-136 3" ALUMINUM OR STEEL POST PER PLAN 0.188" c . 0.188" oo l 0.032" o 3.000' a 0.042" 3.000" 4.000" o 2.000" 3.000" 2.OD0'' NOTE C - ` SEE TABLE 1 ON L1.z FOR APPLICATION OF THIS DETAIL 0 HSS 4 x 4 x 3/16 _ c1lASTM HSS 3 x 3 x 3/'16 / ��. \ 0.042- SIDE PLATES 3- SQ ALUM POST A500 GRADE JASTM A500 GRADE B-1 I ALUM. ALLOY 60637T6 IALUM. ALLOY 3004-1-136 - 0.250° 0 0 0 2 " TYP. 0.`7aoNp6 o.osz' TYP NNOo- 0 . o � oo.2so +� o R04.01205 ri �0" n 4.000° 3.000" 3.000" c 3.000° IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. HSS 3 x 3 x 5/16 HSS 3 x 3 x 1/4 3' MAG POST C2 3" SQ ALUM. POST 3°=1'-0" 3"=1'-0° ASTM A500 GRADE 6 STEEL A653 GRADE 50 CP60 IALUM. ALLOY 3004-1-136 3° ALUMINUM OR STEEL POST PER PLAN IL 1.500' No . 0.313" o nnR0.125 Lj- 0 741'- o 0.400" _ C, + lb TYP. r =1i, 3.000"3.000" CD 0.032" o 2.000" 3.000" 2 Nig•. � IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES�,NO FASTENERS ARE REQUIRED. hm 'SLEEVE SHALL EXTEND FROM THE FOUNDATION, TO THE UNDERSIDE OF SEE TABLE i ON LIx FOR APPLICATION OF THIS DETAIL THE BEAM/COLUMN CONNECTION. C9 HSS 3 x 3 x 5/16 - C6 3.SQ STEEL POST SP3 0.032- SIDE PLATES 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�pFESSIq>� w S5885 m lq UCT� ��Q lF OF CAL DATE SIGNED: Apn15, 2017 VM E1�r3l�E�f/e3 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB S 16-7871 ------------ DATE 04105117 DRAWNBY RER CHECKED -i - - .MDS IAPM0195 V 2.0 LATTICE STRUCTURES: COLUMN PROFILES L4.2 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS lq>�� w S 5885 a_ �9 (JCT�P TF OF Eq�\F� DATE SIGNED: April 5, 2017 .'INMER/E1la 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16-1071 DATE 04!05117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTORS Z.875" p Og0" 0 0 0 0.O6D' 0 0 o ^- ' 3000 Li -000--, NO BRACKET IS 2i'4 LONG r 4 V BRACKEI' Al' COLUMN W BRAMEI _ 6'=1'-0" - N.T.S. 0.065" c TYP. u? 2.275' ;.• LENGTH= 2I�" @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH = 6Y4' @ DOUBLE 2 x Eh BEAM BELOW LENGTH = 83114' 0 DOUBLE 3 x 8 BEAM BELOW V BRACKET-- ? 2 x RAFTER, TO BEAM ,6-1/2' 0.065' n Np co. i 3.315" LENGTH = 2jF @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH = 63'4" @ DOUBLE 2 x 614' BEAM BELOW LENGTH= 8"31' @ DOUBLE 3 x 8 BEAM BELOW V BRACKET -� _ 3 x 8 RAFTER TO BEAM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS lq>�� w S 5885 a_ �9 (JCT�P TF OF Eq�\F� DATE SIGNED: April 5, 2017 .'INMER/E1la 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16-1071 DATE 04!05117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTORS NOTE: WHERE COVER CONSTRUCTION INCLUDES DETAIL A OR B, SITE-SPECIFIC ENGINEERING IS REQUIRED TO VERIFY ADEOUACY OF THE EXISTING STUD WALL FRAMING (INCLUDING HEADER SIZE) WHERE ONE OR MORE OF THE FOLLOWING CONDITIONS OCCUR 2 x 6 or 2 x B LEDGER L8 x 8 x 3/4 x 1 1" LONG BRACKET FOR LUSL = 20PSF MAX COVER PROJECTION > 16 AND OPENING IN WALL WIDER THAN 8' AT EA (E) 2 x RAFTER, WITH (3) FOR SL = 50 PSF MAX COVER PROJECTION > WAND OPENING IN WALL WIDER THAN 6' FASTENERS, SEE TABLE 3 X14 x 3 r WOOD SCREWS. EA LEG 1 /2" MIN LEDGER OR WALL (E) BLOCKING HANGER wl FASTENERS ETWEEN CONT. PER TABLES 3 & 4 SOLID PATIO COVER OR tl2" GRAFTERS OR (E) 1" THICK MAX LATH AND - 3 x ALUM. RAFTER MIN TRUSSES I� PLASTER OR WOOD SIDING z (E) TRUSS OR 2 x WOOD STUD WALL RAFTERS @ 24" OC SIM AT CONCRETE, BRICK (E) WALL OR MASONRY WALL 25 1. MIN. ALLOWABLE PROD. TO BEAM (E) EAVE'OH (E) RAFTER OR TRUSS BACKSPAN SEE TABEL 1 24" MAX 6'-0" MIN 40'-0" MAX .E 1EXISTING ROOF DESIGN LOADS: ROL = 3 PSF (MIN) TO 8 PSF (MAX) 2. NEW PATIO DESIGN LOADS: LL = 10 PSF MAX (NO SNOW LOAD) 3. PLACE "SIKA FLOC OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. THE BRACKET MAY ALSO BE MOUNTED BELOW THE RAFTER AS SHOWN. (� ALTERNATE EAVE CONNECTION I NOTE, WALL LEDGER SHALL BE - NOMINAL LUMBER SIZE 2 x 6 (AT 2 x 6>4 MINIMUM RAFTERS), - NOMINAL LUMBER SIZE 2 x 8 (AT 3 z 8 MINIMUM RAFTERS), OR - KILN -DRY WOOD41LLED 2 x 61' OR 3 x 8 ALUMINUM SECTION. (� WALL CONNECTION 0 TABLE 2 - NUMBER OF SIMPSON A34s REQUIREDAT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG TABLE 1 - MAXIMUM PROJECTION ASSUMING (E) JOIST SPACING = 24 -OC MAX 50 PSF SL WSL AT ROOF OVERHANG E0.STING FRAMING MEMBERR4'0"24V IT 1 1 1 1 1 RHANG LENGTH 8" 12" 6" 2 2x4 FULL 2 11" 24'0' 24'0' 10 2x6 NOTCHED 2 ' 0" 24'0* 24' 0" 2x6 FULL OR 2xB NOTCHED ' 0' 24'(r 24' 0' 2x8 FULL OR 2x10 NOTCHED 0' 24' 0" 24-W 2x4 FULL T9' 11-10' 19-5- 24-0- 20 2x6 NOTCHED 17 3' 1T 10' 24'0* 24' Cr 2x6 FULL OR 2x8 NOTCHED 19' T 24-0- 24' 0" 24-0- 4'0"2x8 2x 8FULL OR 2x10 NOTCHED 24' 0' 24-0- 24' 0" 24' 0' 2x4 FULL r4' 11'3' 18' T 24' Cr 25 2x6 NOTCHED 1118, 1T 0' 24'0" 24' 0' 2x6 FULL OR 2x8 NOTCHED 1&8' 24-0- 24-0- .. 24' 0' 2x8 FULL OR 200 NOTCHED 24' 0' 24' 0' 24' Cr 24' 0' 20 FULL 5111, 9.4" 15' 8" 24-0- 30 2x6 NOTCHED 96* 14'2' 27 11" 24' 0' 2x6 FULL OR 2x6 NOTCHED 15, 5" 27 D' 24' D" 24' 0' 2x8 FULL OR 200 NOTCHED 24-0- 24' Cr 24'T 24'0w' 40 2x4 FULL 4'0' TV 12'(r 24' 0' 2x6 NOTCHED 69* 10' 5' lT 6" 24' Cr 2x6 FULL OR 2xB NOTCHED 1 T 4- 16' 6" 24-0- 24' 0' 2x8 FULL OR 2x10 NOTCHED 19' T 24'0' 24' Cr 24' 0' 2x4 FULL 710' 5' 7 gel 20' 4' 2x6 NOTCHED 5`11 8' 2. 2" 24' 0' 2x6 FULL OR 2x8 NOTCHED 69- 13-0- 6" ]1' 24' 0' 2x8 FULL OR 2x10 NOTCHED 166- 21-11- 0- 24' 0 - NOTCH CAN BE UP TO 1" IN 2x6, UP TO 1.5" IN ZxB OR 2x10. MAX (E) ROOF RAFTERS BACKSPAN IS ASSUMED TO BE 40 FT. I NOTE, WALL LEDGER SHALL BE - NOMINAL LUMBER SIZE 2 x 6 (AT 2 x 6>4 MINIMUM RAFTERS), - NOMINAL LUMBER SIZE 2 x 8 (AT 3 z 8 MINIMUM RAFTERS), OR - KILN -DRY WOOD41LLED 2 x 61' OR 3 x 8 ALUMINUM SECTION. (� WALL CONNECTION 0 TABLE 2 - NUMBER OF SIMPSON A34s REQUIREDAT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG TRIB 10 PSF 20 PSF 25 PSF 30 PSF 40 PSF WIDTH WSL WSL SL SL SL 50 PSF SL 6 1 1 1 1 1 1 IT 1 1 1 1 1 2 T 1 1 1 1 1 2 2 2 9' 7 1 1 1 2 2 10' 1 1 1 2 2 2 11' 1 1 2 2 2 2 12' 1 1 2 2 2 2 USE (8) SIMPSON SD9112 SCREWS INTO EACH A34 WHEN USING (2) A34s, PROVIDE 2x FULL DEPTH WOOD SCAB, FULL LENGTH OF RAFTER TAIL TABLE 3 - FASTENERS REQUIRED AT LEDGER AND ROOF PANEL RAILTO FASCIA OR LEDGER TO EXISTING WOOD STUD WALL FRAMING TRIB ' 10 PSF 20 PSF 25 PSF 30 PSF 40 PSF 50 PSF WIDTH WSL WSL SL SL SL SL S Aj A A A A A 6 A A A A A A' T A A A A A 'A 8' A A A A A A 9' A A A A A B 10' A A A A A C 17' A A A A B C 12' A A --- _A — A B C A (2) 1/4" LAG SCREWS B (2) 5/16' LAG SCREWS C (2) 7/16' LAG SCREWS " NOTES: 1 - ANCHORS ARE TO BE SPACED AT 16" O.C. HORIZONTALLY IN DIRECTION PARALLEL TO WALL 2- WHERE ROOF PANEL RAIL OCCURS, USE i/7' DIAMETER LAG SCREW IN LIEU OF (2)1/4' DIAMETER LAG SCREWS. SIMPSON A34 SEE TABLE 2 ' (E) BLOCKING FASTENERS, SEE TABLE 3 BETWEEN CONT. RAFTERS OR TRUSSES SOUD PATIO COVER OR 3 x ALUM. RAFTER(E) TRUSS OR 2 x FULL DEPTH WOOD RAFTERS @ 24" OC) ' SCAB, WHERE OCCURS, EXISTING FASCIA BOARD SEE TABLE 2 ALLOWABLE PROD. TO BEAM EAVE OH LE1 RAFTER OR TRUSS BACKSP SEE TABLE I 24" MAx 6'-0' MIN 40'-0' MAX NOTE: - EXISTING ROOF DESIGN LOADS: RDL = 3 PSF (MIN) TO 8 PSF(MAX) RLL = 20, 25, 30, 40 OR 50 PSF ti A EAVE CONNECTION TABLE 4 -ANCHORS INSTALLED INTO THE SIDE OF 6 IN THICK MIN CONCRETE OR CMU WALLS IN CONCRETE, USE 117' DIA SIMPSON STRONG -BOLT 2, STAINLESS STEEL, WITH 3" MIN EMBED, INSTALLED PER ICC -ESR -3037. IN CMU, USE 12' DIA SIMPSON WEDGE -ALL, STAINLESS STEEL, WITH 3 318" MIN EMBED, INSTALLED PER ICC -ESR -1396. MAXIMUM ANCHOR SPACING 10, 20, 25 PSF 30 PSF 40 PSF 50 PSF WSL SL SL SL 48" 36" 36" 1 24" USE 3" SQ.xl/4" STAINLESS STEEL WASHER WHEN INSTAWNG NEW WOOD LEDGER AGAINST EXISTING CONCRETE WALL J ■ 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�f ESS Igyq� w Q S5 85 TF OF CAIS DATE SIGNED: April 5, 2017 �;Lkjwv TCS wIMEEf�Ih�G 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MIRK DATE DESCRIPTION 4 STEL JOB # 161071 DATE 09105117 DRAWN BY RER CHECKED _ - _ .MDS - IAPM0 195 V 2.0 LATTICE STRUCTURES: ATTACHMENT TO . EXISTING BUILDING L6: 1 `- (E) BLDG 3' x B" x 0.042' HEADER (E) SPUD WALL (3 0 LAG SCREW TYP j 9 --�- - DECK/RAFTER ��/ ° (3) ;I14 SMS II EA SIDE DIRECTION i! TRIBUTARY — —-------+— — AREA lz 2• l COLUMN E0. E0. MIN. ii o BEAM (E) BLDG \ \ (E) 1° THICK MAX LATH AND BEAM I \ PLASTER OR WOOD SIDING 3' x 8° RAFTER BRACKET I NOTES: COLUMN j TRIBUTARY 1. USE OF THIS DETAIL IS LIMITED TO THE FOLLOWING: %KLA FOR LL/SL = 10 PSF, MAX TRIG AREA TO CONNECTION = 100 Ff� FOR LL/SL = 20 OR 25 PSF, MAX TRIS AREA TO CONNECTION = 55 W E0. E0. FOR SL = 30 PSF, MAX TRIG AREA TO CONNECTION = 45 FT' DECK/RAFTER FOR SL > 30 PSF, DETAIL IS NOT ALLOWED DIRECTION 2. SEE PLAN FOR DEFlNMON OF TRIBUTARY AREA. P 3. BEAM MUST UNE UP WITH EXISTING WALL STUD. BEAM BRACKET EXISTING STUD ALUMINUM MEMBER WITH WALL WITH WOOD FILL OR 2X NOMINAL �! AND LEDGER (NEW OR EXISTING) STUCCO SEE SEE DETAIL B/L6.1 CL �. (3) Y'0 x 2' FULL LENGTH THREADED LAG SCREWS LIDGER TO WALL FASTENERS PER RAFTER PER PLAN BL6.1 LE) 1° THICK MAX LATH AND L L SMS PER 3/1-6.2, PLASTER OR WOOD SIDING TYP U BRACKET, SIM TO N0 2/1-4.3 OR 3/1-4.3 1. MAX SPAN OF SINGLE RAFTER SHALL BE AS FOLLOWS: 10 PSF - 24' FOR 24' SPACING, 36 FOR 16' SPACING 20 PSF - 12' FOR 24' SPACING, 18' FOR 16' SPACING 30 PSF - 8' FOR 24° SPACING, 12' FOR 16" SPACING 2. SEETHIS DETAIL SHALL NOT BE USED FOR SNOW LOADS HIGHER THAN 30 PSF l RAFTER TO LEDGER CONNECTION 1• THICK MAX LATH AND " « PLASTER OR WOOD SIDING nC5RAFTER PER PLAN I ° FOR LL./SL = 10 PSF, x I USE (2)#14 SMS EA SIDE AND (3) Y°m x 3�' LAG SCREWS. FOR LL/SL = 20, 25, OR 30 PSF, Y i USE (3)#14 SMS EA SIDE I AND (3) VO x 314' LAG SCREWS. ° FOR SL = 40 OR 50 PSF, 'T USE (4)#14 SMS EA SIDE AND (3) )4°0 x 3h' LAG SCREWS. a (E) STUD WALL NOTE USE LEDGER PER 2/L6.2 WHERE RAFTER SPACING EXCEEDS EXISTING STUD SPACING, SEE TABLE 3 SHEET L6.1 RAFTER TO STUD WALL J . CONNECTION 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESSIq>� co S5885 9rF.OFC DATE SIGNED: April 5, 2017 WOO ��,EE-FYVG-- TS_nAlE!k�iE'//vG 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 j FAX 949.305.1420 *U APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB aT 161071 DATE OM17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS 1-6.2 ___T 4. �U. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �pFESS IpV4 w o S5885 m lq TSP �\P TF OF- CALLF� DATE SIGNED: April 5, 2017 C�A TCS E/4'G 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL 1\ REVISIONS MARK DATE DESCRIPTION 4 STEL JOB >t 16-ID71 DATE D4W17 DRAWN BY RER CHECKED - ..MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.3 j8 SMS LATTICE % ATTACHMENT PER �� 7/1-6.3 3 x 8 x 0.42 BEAM OR 3" SQ. STEEL BEAM OR MAG BEAM DOUBLE BEAM (4) #14 SMS EA 89, 810, 812, (6)-14 SDS @ EA SIDE RAFTER TO COLUMN B15 OR Bib (8 TOTAL) TOP & BOT TOTAL = 24 z 7J4` SO. OR 2" SO. OR 2 x 3" LATTICE @ 3" O.C. I I 5/8"0 HOLE WITH - MIN. UP TO 6` O.C. MAX @ PLASTIC PLUG, AS H BRACKET PER 1 /S4.3 I I REO'D, TYP. R IS OR 1/LS.3 RAFTER- I Oo I ACCEPTABLE TO USE ONE HOLE TO 3" OR 4" SQ. INSTALL SEVERAL ALUM.. OR STEEL POST I o I SCREWS, TYP. I 3 x 3 x .024 (3) #'14 SMS CONNECTOR EACH SIDE 'LATTICE TUBE TO RAFTER COLUMN TO DBL BEAM If BRACKET TO POST (�)STUB CONNECTION LATTICE ATTACHMENT PER 7/1.6.3 SPLICE WHERE OCCURES 1/2' MAX SPLICE (INT COL ONLY) WHERE OCCURS (INT COL ONLY) (6) $14 SMS @ EACH HEADER TO COLUMN 1/2- TYP DBL RAFTER (12 FASTENERS PER DOUBLE BEAM 89, CONNECTION) B10, B12, 815 OR (4) #14 SMS EA RAFTER 616 - TO COLUMN (8 TOTAL) 5/8"0 HOLE WITH II ` 5/8"0 HOLE WITH . PLASTIC PLASTIC PLUG, AS I o II ® I PLUG, AS REO'D, TYP. IT IS REO'D, TYP. IT IS f ACCEPTABLE TO USE ONE ACCEPTABLE TO 10®® @ I HOLE TO INSTALL SEVERAL USE ONE HOLE _ I SCREWS, TYP. TO INSTALL 0 SEVERAL SCREWS, 10 II I i TYP. I II "I I• ATTACHMENTS PER 2/1-6.3 ® i I I (2) #14 SMS EACH �I I DBL BEAM 89, 810, B12, SIDE T&B @32" I ARCHITECTURAL SIDE O.C. PLATES, WHERE OCCUR, j I 815 OR Bib I SHALL STOP & FLUSH • I I I I 3" OR 4" SQ. POST W/ BELOW BEAM OPTIONAL SIDE PLATE OR ARCH COL WHERE OCCURS 3" OR 4" SQ. POST I 1 DBL RAFTER TO DBL BEAM / \DBL BEAM TO COL _ CONNECTION 1 1/z"=1' 0" 1-1/z"=1' 0• 3" WIDE BEAM TYP B2." MAX B5, Bit, B13 OR 814 1 3" OR 8" BEAM (6)•#14 SMS EA SIDE AT SPLICE 'SMS PER ELEVATION, TYP. AT SIDE PLATE SP3 B a- • (8) #14 SMS EA SIDE o� %"0 PLASTIC PLUG-TYP. AT SIDE PLATE SP4. ` SEE NOTE 1. to Cr w PROVIDE FULL BEARING OF BEAM ON POST. o ' VO HOLE WITH PLASTIC PLUG, AS EL o "r'• REQ'D, TYP. IT IS ACCEPTABLE TO �' o a F • " SIDE PLATE EA SIDE USE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP. (2) $14 SMS EA SIDE AT EW SIDE PLATE EA. SIDE. SEE 3" SQ. POST BETWEEN AND AT 32" OC MAX. TABLE I ON S1.x OR Li.x SIDE PLATESL---14YBOTTOM OPDONAL STYROFOAM INFILL OF E1 SECTION 3` SQ. POST BETWEEN A ELEVATION SIDE PLATEESCbCN STOP BELOW / SIDE PLATES BEAM TO POST CONNECTION R 01Y1 m®1➢WiW 10 /� R. IdIR IOPI[ STJB� J rm x wa ivea / �ertcY rt v mr 3/4"=1'-0" I - -------------- 4. �U. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �pFESS IpV4 w o S5885 m lq TSP �\P TF OF- CALLF� DATE SIGNED: April 5, 2017 C�A TCS E/4'G 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL 1\ REVISIONS MARK DATE DESCRIPTION 4 STEL JOB >t 16-ID71 DATE D4W17 DRAWN BY RER CHECKED - ..MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.3 STEEL SLEEVE PER —4/L7.2 AT POST .TYPE C7, C8, & C9 BOLTS -PER TABLE 2 ADJACENT GRADE TYP.� ADJACENT GRADE TY 3" OR 4" STEEL POST. ii�� 1a ° • -9, I I I D I I �— TRIG WIDTH ° I I - I I—�Er 11'-9" 11'-0" 10'-4" 9'-0" eC • °• 6' 10"-9" 9'-9" 9'-0" 8'-4" ° 7' 10"-0" 9'-0" 8'-0" 7'-6" I I F 8' 9'-4" 8'-6" 7'-6" 7'-0" • — — • °° 9' z 3"MIN. 10' , 8'-6" 7'-6" N.P. NP ox 11' i 4i • PER 4/L7.2 < z 7'-8" 6'-6" NP NP 5'-3" 5'-6" 17x17x3D a ° 14x14 x42 22 - ° ` • ° _ o ~ = Zd )4"A A36 0 THREADED R0Ln 19x19x30 • o 24 24x24x24 .° . is 43 x43x18 24 x24x 24 22x22x30 20x20x 36 18 x18x42 26 _ 9 ° ° B e o STEEL 31 x31 x24 - °• o x' 0 cn ti �cc 25x25x25 35x35x18 (4)-1/2' dia w/ 3-1/4' embed 38x38x24 27x27x30 jPOURED 23x23x42 30 1-711 28x28x28 POURED 235" CONCRETE CONCRETE 28x29x36 FOOTING FOOTING 32 x32x 32 WIDTH =LENGTH IN WIDTH = LENGTH IN - SEE FTG. SCHEDULESEE FTC. SCHED 30x3Ox36 IN BEAM SPAN TABLES IN BEAM SPAN TABLES 34x34x34 NOTES, 1. THIS DETAIL CAN BE USED FOR STEEL POST TYPES C6, C7, C8, OR C9. NOTES: I. THIS DETAIL IS TO BE USED FOR POST TYPES C10 & C11. 2. THIS DETAIL SHALL NOT BE USED FOR STEEL POST TYPES C1, C2, OR C5. 2. THIS DETAIL CAN ALSO BE USED FOR STEEL POST TYPES C6, C7, C8, C9. 3. R IS ACCEPTABLE TO EMBED THE STEEL POST DIRECTLY INTO THE FOOTING 3. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPES C1, C2, PER 5/1-7.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL OR C5. 34x34x34 STEEL POST SLEEVE CONNECTION � 0 TO CONCRETE FOOTING 1"=1'-0" TABLE 3 - (MAX WIND SPEED: 130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE ROLLED FORMED PANS (RF) IRP TRIG WIDTH LL/SL(psf) SL(psf) SO psf 20 psf 25 psf 30 psf U/SL(psf) 10 psf 20 psf 5' 11'-9" 11'-0" 10'-4" 9'-0" 12'-6" 10'-0- 6' 10"-9" 9'-9" 9'-0" 8'-4" 10'-5" 8'-9" 7' 10"-0" 9'-0" 8'-0" 7'-6" 9'-0' 8'-0" 8' 9'-4" 8'-6" 7'-6" 7'-0" T-10" V-6- 9' 8'-10" 8'-0" 7'-0" NP 7'-0' 7'-0" 10' , 8'-6" 7'-6" N.P. NP 6'-3" 6'-6" 11' 8'-1" 7'-0" NP NP 5'48" 6'-0" 12' 7'-8" 6'-6" NP NP 5'-3" 5'-6" NOTES: 1 -"NP" INDICATES THAT A FOOTING IS REQUIRED, AND THE PATIO COVER CANNOT BE SUPPORTED ON A SLAB ON GRADE. 2- FOR UVE OR SNOW LOADS HIGHER THAN THE ONES SHOWN ON THIS TABLE, A FOOTING IS REQUIRED AND THE PATIO COVER CANNOT BE INSTALLED ON SLAB ON GRADE. / \ STEEL POST EMBEDDED' INTO CONCRETE FOOTING? 1"=1'-0" 3" STEEL OR ALUMINUM POST ADJACENT GRADE WHERE OCCURS 6" MIN. -o ( o i EDGE OF SLAB WHERE OCCURS 7 BRACKET PER 1/L7.2, 2/1-7.2 OR 3/1-7.2 EXISTING OR NEW SLAB ON GRADE fc=2,500 PSI MIN. PER TABLE 2 NOTES: 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C3, C5, OR C6. 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES AND/OR COMMERCIAL APPLICATIONS. 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, C10, C11. 4. SLAB ON GRADE SHALL BE IN GOOD CONDITION (NO VISIBLE CRACKS WITHIN 33" FROM POST). 5. MINIMUM OVERALL DIMENSION OF SLAB ON GRADE SHALL BE PER FOOTING NOTE 4 ON GO.1 NOTES: 1- "FTG (I N)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS 58.rocx OR LBxxx. . 2 -'ALT 1' IS THE FOOTING DIMENSION BASED ON THE `FTG (IN)- DIMENSION. NOTE THAT W=Di 3 - "ALT 2- IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A35— MIN THICK SLAB IS PRESENT ABDVE THE FOOTING. NOTETHAT Wed. 4-"ALT3' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18' DEPTH FOR UPLIFT DESIGN ONLY. THIS VALUE ISTO BE USED ONLYATATTACHED PATIO STRUCTURES. NOTETHAT W=L AND D=18". 5 -'ALT 4' IS THEALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18' DEPTH. NOTETHAT WaLAND D=18'. 6 -'ALT 5' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 24' DEPTH. NOTE THAT W d AND D=24'. 7 -ALT 6' IS THEALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 30" DEPTH. NOTE THAT WdAND D=30`. 8 -'ALT 7" IS THE ALTERNATE FOOTING DIMENSION REQUIRED W HEN THE FOOTING IS KEPT TO AN 36- DEPTH. NOTE THAT W d AND D=36'. 9-'ALT8' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 42' DEPTH. NOTE THAT Wd AND D=42-. i \FOUNDATION TABLES J TABLE 2 - ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) TABLE 1 ALTERNATE FOOTING DIMENSIONS BRACKET DETAIL POSTTYPE FTG (IN) ANCHOR BOLTS (SEE NOTE 2) FTG (IN) W=L=D (SEE NOTE 1) Altl WxLxD (SEE NOTE 2) AIt2 WxLxD (SEE NOTE 3) Alt 3 (ATTACHED) WxL%1B" (SEE NOTE 4) ata WxLx18" (SEE NOTE 5) Aft 5 WxLx24" (SEE NOTE 6) AIt6 WxLx30" (SEE NOTE 7) AIt7 WxLx36" (SEE NOTE 8) ata WxLx42" (SEE NOTE 9) 18 18x18x 18 12 x 3 2 x 12 28x 18x 16 18x18x18 16x16x 24 14x 14x30 13x 13x 36 12x12 x42 20 20x2Ox20 12112x12 21x21xIB 25x2Sx18 19xl9x24 17x17x3D 15x15x36 14x14 x42 22 - 22x22x22 16x16x16 25x25x18 33x33118 21x21x24 19x19x30 17x17x36 16x16x42 24 24x24x24 20 x20x20 28x28x18 43 x43x18 24 x24x 24 22x22x30 20x20x 36 18 x18x42 26 26x26x26 23 x23 x23 32x32x18 STEEL 31 x31 x24 24x 24x30 22 x22x 36 21x21x42 28 28x28x28 25x25x25 35x35x18 (4)-1/2' dia w/ 3-1/4' embed 38x38x24 27x27x30 25x25x36 23x23x42 30 30x3Ox3O 28x28x28 39x39x18 235" (4)-3/4'diaw/4-3/4'embed 3Ox3Ox30 28x29x36 26x26x42 32 32 x32x 32 30 x30x 30 43x43x18 - ALL 37x 37x 30 30x3Ox36 28x28x42 34 34x34x34 32 x32x32 47x47x18 33x33 x36 31x31x42 36 36x36x36 34x34x34 51x51x19 36x36x36 34x34x42 38 38x38x38 37x37x37 SSx55x18 43x43x36/ 36136x42 40 40 x40x 40 39 x39x 39 60x 60x 18 39x39x42 42 42 x42 x42 41x41.41 64x64xl8 42x42x42 NOTES: 1- "FTG (I N)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS 58.rocx OR LBxxx. . 2 -'ALT 1' IS THE FOOTING DIMENSION BASED ON THE `FTG (IN)- DIMENSION. NOTE THAT W=Di 3 - "ALT 2- IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A35— MIN THICK SLAB IS PRESENT ABDVE THE FOOTING. NOTETHAT Wed. 4-"ALT3' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18' DEPTH FOR UPLIFT DESIGN ONLY. THIS VALUE ISTO BE USED ONLYATATTACHED PATIO STRUCTURES. NOTETHAT W=L AND D=18". 5 -'ALT 4' IS THEALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18' DEPTH. NOTETHAT WaLAND D=18'. 6 -'ALT 5' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 24' DEPTH. NOTE THAT W d AND D=24'. 7 -ALT 6' IS THEALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 30" DEPTH. NOTE THAT WdAND D=30`. 8 -'ALT 7" IS THE ALTERNATE FOOTING DIMENSION REQUIRED W HEN THE FOOTING IS KEPT TO AN 36- DEPTH. NOTE THAT W d AND D=36'. 9-'ALT8' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 42' DEPTH. NOTE THAT Wd AND D=42-. i \FOUNDATION TABLES J NOTES: 1 -'FTG (INY IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS L8xxx 2 - ANCHOR BOLTS SHALL BE SI MPSON STRONG BOLT 2, STAINLESS STEEL (ICC -ESR 3037) 3 - IT IS ACCEPTABLE TO USE THE STEEL INSERT PER 4/1.7.2 1 NSTEAD OF THE AWMI NUM T PER 2/L7.2 FOR POSTTYPES C2 AND CS. BOLTS CAN CAN REMAI N AS SPECI FI ED I N THIS TABLE 4 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL S/L7.1 I NSTEAD OF THE STEEL I INSERT OR STEEL T FOR STEEL POSTS C6. 5 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAI L S/L7.1 I NSTEAD OF THE STEEL I NSERT FOR STEEL POSTS C7, C8 AND C9. 3" STEEL OR ALUMINUM POST z (�. w� 4 NN 4. e " WIDTH = LENGTH IN SEE FTG. SCHEDULE I BEAM SPAN TABLE i BRACKET PER 1/L7.2, 2/L7.2, OR 3/1-7.2. BOLTS PER TABLE 2 ADJACENT GRADE TYP. CONCRETE FOOTING NOTES: 1. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 2. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, C10, Ci 1. ANCHORAGE OF POSTS T BRACKET ftOTING TION Y TO SLAB OR FOOTING 2 TO CONCRET1•=1'-0' �. u DURALUW 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Igy9� Fn S.5885 cc rq GCT TF OF CAS DATE SIGNED: April 5, 2017 EI�fG!/�E�t�s/iVG 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AW APPROVAL REVISIONS NIA.RK I DATE DESCRIPTION 4 STEL JOB 9 16-11171 DATE 041MIT DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS __. - ---1-7.1 �--- -- TABLE 2 - ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) BRACKET DETAIL POSTTYPE FTG (IN) ANCHOR BOLTS (SEE NOTE 2) SEE NOTES ALUM T 1/1.72 Cl SOG W-3/8" dia w/ 1-7/8" embed ALUM T 1/1.7.2 'C1 ALL (2}3/8' dia w/ 2-7/8' embed ALUM T 2/L7.2 C2 SOG W-3/8' dia w/ 1-7/8' embed 3 ALUM T 2/L71 C2 ALL (2}3/8' dia w/ 2-7/8' embed 3 ALUM T 2/1.7.2 CS SOG (2)•3/8' dia w/ 1-7/8' embed 3 ALUM T 2/0.2 CS ALL (2)-3/8' dia w/ 2-7/8' embed 3 STEELT 3/1.7.2 C6 SOG W-3/8' dia w/ 1-7/8" embed STEEL 3/1.71 C6 S 22" M-3/8" dia w/ 2-7/8' embed 1,4 STEEL 3/1.72. C6 524" (2)-1/2'diaw/3-1/4'embed 1,4 STEEL INS 4/1-7.2 CG 5 30" (4)-1/2' dia w/ 3-1/4' embed 1,4 STEELINS 4/1.72 C6 534" (4)-S/8'diaw/4'embed 1,4 STEEL INS 4/1.72 C6 235" (4)-3/4'diaw/4-3/4'embed 1,4 STEEL INS 4/1.72 C7, C8, C9 ALL (4)-3/4" dia w/4-3/4' embed 1S EMBED S/L7.1 C10,C11 ALL N/A NOTES: 1 -'FTG (INY IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS L8xxx 2 - ANCHOR BOLTS SHALL BE SI MPSON STRONG BOLT 2, STAINLESS STEEL (ICC -ESR 3037) 3 - IT IS ACCEPTABLE TO USE THE STEEL INSERT PER 4/1.7.2 1 NSTEAD OF THE AWMI NUM T PER 2/L7.2 FOR POSTTYPES C2 AND CS. BOLTS CAN CAN REMAI N AS SPECI FI ED I N THIS TABLE 4 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL S/L7.1 I NSTEAD OF THE STEEL I INSERT OR STEEL T FOR STEEL POSTS C6. 5 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAI L S/L7.1 I NSTEAD OF THE STEEL I NSERT FOR STEEL POSTS C7, C8 AND C9. 3" STEEL OR ALUMINUM POST z (�. w� 4 NN 4. e " WIDTH = LENGTH IN SEE FTG. SCHEDULE I BEAM SPAN TABLE i BRACKET PER 1/L7.2, 2/L7.2, OR 3/1-7.2. BOLTS PER TABLE 2 ADJACENT GRADE TYP. CONCRETE FOOTING NOTES: 1. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 2. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, C10, Ci 1. ANCHORAGE OF POSTS T BRACKET ftOTING TION Y TO SLAB OR FOOTING 2 TO CONCRET1•=1'-0' �. u DURALUW 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Igy9� Fn S.5885 cc rq GCT TF OF CAS DATE SIGNED: April 5, 2017 EI�fG!/�E�t�s/iVG 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AW APPROVAL REVISIONS NIA.RK I DATE DESCRIPTION 4 STEL JOB 9 16-11171 DATE 041MIT DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS __. - ---1-7.1 �--- -- �-r �r< ! - l 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 pp Q�FESSIIco gQ��� " S 5885 m T �\Q qTF OF DATE SIGNED: April 5, 2017 r,A %C�_ clJwJeERIlVig 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R - 161071 DATE 04W17 DRAWN BY RER CHECKED -MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS L7.2 Oo Oo ASTM A555 GRADE B ALUM ALLOY 6063-T6 _ 2.875" (4)-g14 SMS OR TEK SCREWS, Qo Qo NSERT TO EA. SIDE, TYP. PLAN 3(s BASE PL 3" STEEL POST o I I VO HOLE EA SIDE 0.188" THICK MIN �o HSS INSERT I 0.085" TYP. I - 'y4-0 BOLTS 0.750" ` 5.662" TVP. �(3) a --- 10" SO. BASE PL o - - NOTES T.O.C. 1. BRACKET LENGTH IS 2.75" 2. THIS BRACKET IS TO BE USED WITH POST TYPE Cl. WITH OR WITHOUT ELEVATION ` SIDE PLATES PER SP3 OR SP4. NOTES: 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. - 1. THIS BRACKET IS TO BE USED WITH POST TYPE C7, C8 & C9, AND WITH C6 4, INSTALL 1Y4 x 1Y x Jg HOG WASHER PLATE AT ANCHORS FOR 130 MPH WHEN FOOTING SIZE IS 25" OR LARGER. 2. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 3. INSTALL IX x 1Y4 x X HOG WASHER PLATE AT ANCHORS SMALLER THAN Y{O. 4. THIS BRACKET CAN ALSO BE USED FOR POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SMALLER STEEL POST SLEEVE ALUMINUM T -BRACKET 4 FOR POSTS C7, C8, C9 3/4"=1'-0" FOR POST Cl 3"=1'-0" ALUM ALLOY 6063-76 4-#14 SMS 406' OR SEK SCREWS, < I2 EA SIDE, TVP. I ib"0 HOLE EA SIDE ' I 0.094" TYP. I 0.750' ti 5.50" 'I TYP. NOTES: - 1. BRACKET LENGTH IS 2.75". 2. THIS BRACKET IS TO BE USED WITH POST TYPE C2 OR C5. WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. T 4. INSTALL % x U4 x Jia HOG WASHER PLATE AT ANCHORS FOR 130 MPH. 5. STEEL T -BRACKET PER 3/1.7.2 CAN BE USED IN LIEU OF THIS BRACKET. ALUMINUM T -BRACKET 2 FOR POSTS C2, C5 3•=1'-0" - DTM7�55" 4•00' ASTM A500 GRADEFB 1 75" 4- (s 0 HOLES 1 3(s0 & 2-V- O CLO O N HOLES, TYP EA SIDE .. o ,n o n^ 0 0 0 0 ' r ` PLAN 2� 00' - 3.50" 1.00" L ' TP ro 2-3(;0 HOLES FOR \ 0 %'0 M.B. TYP. ELEVATION ---- - NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SMALLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON L7.1 AND 2/1.7.1 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. STEEL T -BRACKET 3 _ FOR POST C6 �-r �r< ! - l 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 pp Q�FESSIIco gQ��� " S 5885 m T �\Q qTF OF DATE SIGNED: April 5, 2017 r,A %C�_ clJwJeERIlVig 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R - 161071 DATE 04W17 DRAWN BY RER CHECKED -MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS L7.2 ATTACHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD -130 MPH - EXP. B & C B14 312 GA STL INSERT V! 815 DBL 14 GSTL INSERT816 %?—DBL 12 GA STL INSERT i BS SO.ALUM W/ 12 GAASTL"U"CHANNEL 89 ATTACHED DBL 2x6.5x0.042 FREESTANDING 811 3x8 x0.042 B10 DBL 2x6.5x0.032 812 MAX DBL3x8x0.042 MIN. 813 3x8x0.042 MIN MAX MIN. MAX MIN. MAX MIN. TRIB WIND .POST FTG. POST POST FTG. POST POST FTG. POST POST. FTG. POST POST FTG. POST POST FTG. POST WIDTH EXP. SPACING > 14 GA STL INSERT TYPE SPACING (IN.) TYPE SPACING ATTACHED FREESTANDING ATTACHED ' FREESTANDING ATTACHED FREESTANDING ATTACHED TYPE FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIG WIND MAX POST MIN. FTG. MAX POST FTG MIN. MAX POST FTG. MIN. ,. MAX POST FTG• MW. MAX POST FTG. MIN MAX POST 19 MIN. MAX MIN. MAX MIN. MAX C2 MIN. MAX MIN. MAX MIN. MAX MIN. WIDTH EXP. SPACING POST 2g4" qp POST 130 c 21'-10" 21 C2 20-10" 36 C11 28'-2" 23 C5 POST 6, 130 B POST 19 POST 34 FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST 39 C11 151" 36 C9 25'-9" 24 (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TOPE SPACING (IN) TYPE SPACING (IN.) TYPE SPACING (IN.) TOPE SPACING (IN.) TOPE 8, 130 B (SPAN) 20C2 (SPAN) 1T-0" 33 (SPAN) 23'-2' 22 (SPAN) 22'-5 35 (SPAN) 25-3" 23 (SPAN) 25-3" 35 (SPAN 130C (SPAN) 23 (SPAN) 238 1 37 (SPAN) 16'-T 34 C8 27-3" 25 21'-3" 37 Cil 25'3 2B (SPAM 13D B 1T8' (SPAN) C5 16-8" 5' 130 B 16-5 17 C1 14-T 33 C9 14-10 16 23 14'-10" 31 35 15.4" 16 130 C 15-2 31 181-W 17 37 1T 8" 33 C7 21'-0 19 16'-1" 21'4" 34 C8 2V ­T Is- 20-5 20'-0" 32 C8 34 130 C 15'-0" 19 C1 C7 Cl 14'-2" 33 C7 1T3" 20' •C1 C1 19'-1" 34 C9 14-7- 34 C10 14' 4" 19 13' 8" 33 t4'-10" 19 16'-0" 34 C8 20'-10" 21 20-0" 36 C11 20-0" 21 C1 6, 130 B 15-3' 18 Cl 13'-3" 31 C9 13'-T 17 C8 13'-T' 31 C5 14' 1" 17 C9 13'-1D" 31 16'4" 18 C9 16'-7' 32 C7 19'3' 19 14-7 19'-T 33 C8 19-T 19 Cl 18S 32 C8 18'-T 35 21'8 27 130 C 13'3 20 C1 C7 C7 C7 15'-10" 20 Ct C2 13'-3" 34 C10 13'-1" 19 1Z-0 32 13'-T 19 13'-0 32 15-1" 33 C8 15-1" 22 18-3" 35 C9 18'-3" 21 C2 17.6" 33 C9 7, 130 B 14'-T 18 Cl 124" 31 C8 17-T 17 36 12'-T 30 13 1` 1T 17-10" 30 15'-T 18 15-0" 31 C7 18'4" 20 18'-1" 33 IT -7" 19 1T3' 31 C7 130 C 1T-5 20 C1 C7 C1 17-1" 31 C7 14'S 21 Cl C2 16=10" 34 C8 1T•U' 22 C2 16'-2' 33 C8 174" 33 C10 17-2 20 11'T 31 177- 20 14'-0" 33 C8 Ir4r 22 e, 130 B 13'-3" 18 C1 11'-T 30 C8 11'-9" 18 Cl 11'-9" 29 17-3" 18 17-1' 29 14'-3" 19 C1 14'-1" 31 1T-7 20 1T-0" 32 C7 16'8 20 16'7 30 C7 130 C 11'-10" 20 C7 c1 11'-3' 31 C7 C2 15'-7 32 C8 11'-T 32 C10 11'4" 20 10-10" 31 11;_ 2D 13'3' 21 C2 C7 13'-1" 32 16'-T 23 C2 15-10' 34 CB 1S-10" 22 91 130B 17-7" 19 C1 11-0" 30 CB 11'-2" 18 C1 11'-7' 29 11-T 18 11'4' 29 13'8 19 62 13'-3" 30 16'-3" 21 16,0" 32 C7 158 20 15'-3' 31 C7 130 C 1T-3' 21 C7 C1 10-0" 30 C7 13'-0" 22 174" 32 C7 1S$ 23 C5 143 32 C8 11-0" 32 C9 10'-9" 21 10'-3" 30 11-2" 21 15-0" 33 CB 15-0 23 10' 130 8 178 19 C2 10'4' 30 C8 10'-T 18 10'-T 29 11'4T' 18 ILr4r 29 12'-9" 20 12-T 30 154" 21 1S-2" 32 C7 14'•9" 21 143' 31 . Cl C7 C1 C7 12'-0" 22 13'-T' 31 C7 130 C 10'S 21 Cl 10'4" 32 C7 10'-T 21 5-9" 30 10'-7- 21 9'-1t;' 30 11'-9" 31 C7 14'-10" 24 14'-T 33 C8 14' 2 23 11s 1308 11'4" 19 C2 9'-10" 30 C8 117-9" 19 C1 29 108 19. 10'-3" 29 17-7 20 1 17-0" 31 14'$ 21 14'8 32 C8 14'-1" 21 13'-1V 32 C7 130 C 10'-7 22 C7 9'-10" 21 C1 9 0 31 C7 11'-9" 23 C2 11' 3" 31 C7 14'-2" 24 C5 13'-0 31 C8 9'-10" 32 C9 9 9" 21 9-3 31 13-T 32 C7 13-T 24 17' > 130.8 10-10" 20 C2 9'8' 31 C8 9'-8" 19 9'$" 29 9'-B" 19 .94" 29 11'8' 20 11'8 31 14'-1" 22 13'-10' 32 138 21 13'-0 32 130 C 9'3' 22 C7 C7 11'3" 23 C2 C5 13'-0" 32 C8 13-0 24 12'8' C7 9'b" 33 C70 9'4" 22 9'-0" 31 9'-1"' 22 8' 3' 31 10-9" 31 C7 13'-T 24 B14 312 GA STL INSERT V! 815 DBL 14 GSTL INSERT816 %?—DBL 12 GA STL INSERT NOTES: WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING(SPANr SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 611.7.1 i ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN. MAX MIN. MAX MIN MAX MIN. MAX MIN. MAX MIN. TRIB WIND .POST FTG. POST POST FTG. POST POST FTG. POST POST. FTG. POST POST FTG. POST POST FTG. POST WIDTH EXP. SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING ON.) TYPE SPACING (N.) TYPE (SPAM (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 5 130 B 278 19 Cl 274' 35 C9 29'-2 20 C2 28'-9" 37 37-0 .31 37-0" 38 CS 2g4" qp C11 130 c 21'-10" 21 C2 20-10" 36 C11 28'-2" 23 C5 26'-10" 39 Cil 37-0" 24 6, 130 B 20'8' 19 20'4" 34 CS 26'43" 21 CS 26'-3" 36 29-2" 22 29'-7' 37 130 C 2Y -f7 22 C5 26'-10' 39 C11 151" 36 C9 25'-9" 24 24'-T 38 C71 29-2" 25 7 130 B 19 2" 20 02 18'-10i 33 C8 24'-0" 22 CS 24'4" 35 C9 2T-1" 22 2T-1" 36 130 C 16-0" 23 CS 24'-10" 38 C11 1T-0" 35 C9 23'-10" 25 22-5 37 C11 2T-1" 25 8, 130 B 16'-0" 20C2 1T-0" 33 C7 23'-2' 22 22'-5 35 C9 25-3" 23 25-3" 35 C10 130C 1T4" 23 CS 238 1 37 1 C11 16'-T 34 C8 27-3" 25 21'-3" 37 Cil 25'3 2B V 13D B 1T8' 21 C5 16-8" 32 C7 21'-10" 23 CS 21'•6" 34 C8 23-10" 23 23'-10" 35 C9 130 C 164" 24 CS 27-0" 37 C11 1S-7- 34 C8 21'-1' 26 20'-1" 36 C11 23-10" 26 10, 130 B 16'-1" 21 C5 15'-10" 32 C8 20-5 23 C5 20'4" 34 C8 22'-8" 24 274" 35 C9 130C 1ST 24 14-10" 33 20-0' 26 2(r-i(r 36 C11 19'-1' 36 C9 2Z- 27 11' 130 B 15:4" 22 C5 15-2" 32 C8 1913' 23 C5 19'8' 35 C9 21'•8" 24 21'S 36 C9 130 C 14'-10" 24 14-7 33 19'-1" 27 C5 19-10": 36 C17 18'-T 35 21'8 27 12' 130 B 14'-9" 22 C5 14'8 33 CB 19'-0" 24 C5 18'$" 35 C9 20'-8" 24 20'8' 36 C10 130 C 14'-7' 25 13=T 32 18'-3 27 C5 8' 17' 35 20'x" 28 15-1" 36 C9 NOTES: WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING(SPANr SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 611.7.1 ;max 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ?0 ESS Igyq Z S588 TF OF CALF DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420,_ AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 161071 DATE D41D6d17 DRAWNBY RER CHECKED MDS IAPM0195 V 2.0 . LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LL/SL, 130 MPH ---L8.-10_3 __ i ;max 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ?0 ESS Igyq Z S588 TF OF CALF DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420,_ AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 161071 DATE D41D6d17 DRAWNBY RER CHECKED MDS IAPM0195 V 2.0 . LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LL/SL, 130 MPH ---L8.-10_3 __ s - 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ESS I( CO S 5885 m TF OF CA0 DATE SIGNED: April 5, 2017 "' ,A ,WV 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB A 161071 DATE 0410917 DRAWN BY RER CHECKED 'MDS IAPM0 195 V 2.0 ADDITIONAL STATE LICENSURE STAMPS G9.1 �1DEESSIgtirq� X00 L IC�� K S\ORAL Fly Q�DfessionD/Fn a E I c q �� o ��\� K �S � O• .... • F�,_ K figs• IES' k �,o i Fps �o \GENS6 F� y v 49725 i V •��� `°° =� LIC 2 DUSTIN 63 S 5885 15287 �• PRENGINEEROSOAL 16508 ROSEPINK u'\ 9 `�Tgr�i'GCTI���Q �F •• No. 15287 9 P� OF \� R�ZONA US•P FOF CP,0E SS/ONAL•� �iq 1 U S T7N ROS�P\ ARIZONA LICENSE CALIFORNIA LICENSE COLORADO LICENSE HAWAII LICENSE IDAHO LICENSE IIIc' II�//,'i `S`~! % \\\'' K:.ROS�'�,� `\\\\\\\\1111{ 1111111/f ,/ KENS '%, .. OF '`�tsso ``'ic\`�i% `.`�-0\A J`: �\GENSFo• Aiy � \�..`` �pF _ ,c� DUSTIN �G\NEER_ST DUSTIN K.ROSEPfNF:USTIN h�*'� K. 'DUSTIN ROSEPINKII = _ _ - = 20550 = ROSEPINK =_ _ * 32350 * = * * ROSEPINK U Z ' 081.007404 i _ O �; ?"Qz •!�C �� NU\1BER z o PE -2015025032 t'r uJ m 0 CIVIL T -- •` - ='Z�' ; � '•.kANSP`?:'GN ;� •,'�.,%NA� �� SAO:' F -... EN �\,�' F �� a0 o �0. �/j ``\\• �.`�` '''''i`S'�ONAL E ?\���`` s/pN,�L EAG 01986 rnNnmaa\ ILLINOIS LICENSE KANSAS LICENSE KENTUCKY LICENSE MISSOURI LICENSE NEVADA LICENSE \\�wili111// �.1EW ley/�� AcS1� \� K • Rps �A \\` �NICARo'/.,' �OpFESS%p4�'j�9 ' Q�pFEss �O� DUSTIN ��<c�\�� ED PROFFS �NGWEF� SOZv DUSTIN K. _ JCS c p 2 o _ Q _ �O ROSEPINK 81971PE - cn ROSEPINK m = 20460 = SEAL = _ _ No.15302 = C�ENS�GO �Q� v �O� _�� = 035378 = - - O F C': :^ Gs •.hGINE�• PE -10228 m d a OREGON G ' F \\ F SS/ONAI \��: �oRT>y Sr��K.R0 S/ON�I111\\\\\\\ ''�r��K�R�s�e`��` DP�O�P NEW HAMPSHIRE LICENSE NEW MEXICO LICENSE NORTH CAROLINA LICENSE NORTH DAKOTA LICENSE OREGON LICENSE 00000DDp — o .�E OF j,&yyDO� gTRUCTOR K.RO Engine DUSTIN K. ROSEPINK o gyp;°°°° °°0°;0,9 �O 0 50 �P 9� o ,� S(�• st,, c, w 4s,, 1. C. \0�\al �5`� K R ei os �c1. � 12202y �2� 2139 o°°°°°°°°°°°°°°°°°°°°°°o*° DUSTIN-- ROSEPINK No. 9466229-22034 w (ILL z ^ ................................O DUSTIN ROSEPINK m REGISTERED _ • PROFFESSIONAL ENGINEER D 45432 C (srRuctuRAL) C '�SS70jAL S/ORA.. o `SAT IRP E OF O M S N ' d\o �OOOoo RHODE ISLAND LICENSE TEXAS LICENSE UTAH LICENSE WASHINGTON LICENSE WYOMING LICENSE r + NOTE PROFESSIONAL STAMPS ARE SHOWN WITHOUT THE LICENSE RENEWAL DATE. PLEASE CHECK WITH THE STATE WHERE THE PROJECT IS BUILT OR CALL 4STEL ENGINEERING FOR CURRENT LICENSE 1 RENEWAL DATE. s - 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ESS I( CO S 5885 m TF OF CA0 DATE SIGNED: April 5, 2017 "' ,A ,WV 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB A 161071 DATE 0410917 DRAWN BY RER CHECKED 'MDS IAPM0 195 V 2.0 ADDITIONAL STATE LICENSURE STAMPS G9.1