Loading...
BMCH2018-0071� iull�Cl/ VOICE (760) 777-7125 78-495 CALLE TAMPICO DFAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN &DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 3/20/2018 Permit Type/Subtype: MECHANICAL/ Owner: Application Number: BMCH2O18-0071 ALT SCHEELA Property Address: 55027 FIRESTONE !/Ja=—a�� 027 FIRESTONE APN: 775151033 q QUINTA, CA 9?253 Application Description: SCHEELA RESIDENCE / HVAC C A UT MAR 2 O ZO18 Property Zoning: M Application Valuation: $26,866.00 CITY OF LA QUINTA Applicant: DESIGN AND DEVELOPMENT DEPARTMENTntractor: IE INC HARRISON ENTEF.PRISES INC DBA GENERAL AIR 31225 LA BAYA 31170 RESERVE C=RIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 686310 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the, basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property,.or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjuy that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: (760)343-7488 Llc. No.: 686310 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 370C of the Labor Code, for the performance of the ork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD503165802 I certify that in the performance of the work for which this permit is issued, I I not employ any person in any manner so res to become subject to the workers' ipensation laws of California, and agree that, if l should become subject to the kers' compensation provisions of Section 3000 of the Labor Code, I shall forthwith iply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this appliotion is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of im-suance of such permit, or cessation of work for 180 days will subject permit to cancellation. . I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatves of this city to enter upon the above-mentioned property for inspection purposes. cant or ' Date: 3/20/2018 Application Number: BMCH2018-0071 Owner: Property Address: 55027 FIRESTONE WALT SCHEELA APN: 775151033 55027 FIRESTONE Application Description: SCHEELA RESIDENCE / HVAC CHANGE OUT LA QUINTA, CA 92253 Property Zoning: Application Valuatidn: $26,866.00. Applicant: Contractor: IE INC HARRISON ENTERPRISES INC DBA GENERAL AIR 31225 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)343-7488 -'-------------------------------------------------------------------------------------------- Llc. No.: 686310 Detail: (2) HVAC CHANGE OUTS AND (15) DUCTS -14 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. a FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATIO V BSA: $2.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION 101-0000-42402 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - REPAIR/ALTERATION PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $78.02 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $156.04 Total Paid for CHANGEOUT: $252.26 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE '502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 -- CEM f,t VESE•.WT-------- PERMIT # PLAN LOCATION: Project Address' 55027 Firestone Project Description: Pool, Remodel, Add't; Elect, Plumb, Mech APN #: Replace (2) 4 ton / 90,000 BTU complete -lVAC systems & 15 ducts Patio/Porch SF Email: Applicant Name: Steven Schnierer State Lic: 686310 City Bus Lic: Address: 31225 La Baya Drive Suite 213 State Lic: City Bus Lic: City, ST, Zip: Westlake Village, CA 91362, Telephone: 818-735-7876 Lmail: swschnierer@roadrunner.com " Valuation of Project $ 26,886.00 Contractor Name: General Air Conditioning New SFD Construction: Address: 31170 Reserve Drive Conditioned Space SF City, St, Zip Thousand Palms, CA 92276 Garage SF Telephone: 760-343-7488 Patio/Porch SF Email: Fire Sprinklers SF State Lic: 686310 City Bus Lic: = Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Construction Type: Occupancy: Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name:Walt Scheela New Commercial / Tenant Improvements: Address: 55027 Firestone Total Building SF City, ST, Zip La Quinta, CA 92253 Construction Type: Occupancy: Telephone: 651-338-4110 Email: 78495 CALLE TAMPICO LA 4UINTA, CA 92253 760-777-7000. OFFICE USE ONLY # Submittal Req'd Ree'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report ' Grading Plan (PM 10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) Project Name: WALT SCHEELA I Date Prepared: CF1R-ALT 02-E (Page 1 of 3) 2018-03-16 A. General Information CF1R-ALT-02 is applicable.to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 .Project Name WALT SCHEELA 02 Date Prepared 2018-03-16 03 Project Location 55027 FIRESTONE 04 Building Type Single family 05 CA City La Quinta06 -'-- Dwelling Unit Name HOUSE 07 Zip Code `3 �E 92253 ' Dwelling Unit Conditioned 2654 Installing new SC Installing )l08 Installing: Floor Area (ft2) Identification or Location or Area by this SC ducted containing Number of Space more than 40 09 Climate Zone 15 ' "" " 10' Conditioning (SC) Systems in 1 system? component? components? feet of ducts? this Dwelling Unit: SC system? .B. Space Conditioning (SC) System Information 01 02 03 04 0 05 1� i 06 ; 07 08 09 10 Is the SC Installing a SC System . SC System CFA served system a refrigerant Installing new SC Installing Installing Installing: Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type SYSTEM 1 LOCATION 1 1327 Yes Yes Yes Yes No No Altered space conditioning system SYSTEM 2 LOCATION 2 1327 Yes Yes Yes Yes No No Altered 9peee conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 418-A020016236A-000-000-0000000-0000 Registration Date/Time: 2018-03-16 10:06:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-16 10:06:19 Schema Version: rev 10/16 - CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) O1 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System' Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value SYSTEM 1 Central gas All new heating AFUE 0.8 Central split All new cooling SEER 14 Setback Greater than R-8 furnace AC 40 feet components components Central gas All new Central split . -, ':.All new *�. Greater than SYSTEM 2 furnace heating AFUE 0.8 AC i t: rt cooling SEER 14 Setback 40 feet R 8 components°-�:� components Required Documentation: LJL' CF2R-MCH-03-E - Space Conditioning Systems r C„ Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6,(CZ`1=10 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF311-10CH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or.when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15% or <= 30% leakage to.outside, or seal all accessible leaks. , CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required Exceptions: � S.a � i �-.-,�y • � � }��+. from -Duct Testing Duct systems registered with HERS provider as previously sealed are exempt MCH -20 Leakage requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air flow MCHf13; or Re6lgerant Charge lvldw . -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)iC) This section does not apply to this project. ti Registration Number: 418-A020016236A-000-000-0000000-0000 Registration Date/Time: 2018-03-16 10:06:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-16 10:06:19 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Patty Hernandez Patty fiernaedelk Company: Signature.Date: I Permit E Raters 2018-03-16 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 91362>L,�yr 818-J35 7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance Is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibilityfor the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices.for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building, design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency:for-approval with this building permit application. S. I will ensure that a registered copy of this Certificate of Compliance shall be made available -with the building:permit(s)-issued for the building, and made available to the enforcement agency for all applicable 'iuinspections. I understand thata registered copy of this Certificate ofComPliance isre uired-to be includedIded with°the documentation the builder provides to the building owner at occupancy. N• Responsible Designer Name: Responsible Designer Signature: Patrick Somers Patrcck.somerk . Company: Date Signed: General Air Conditioning 2018-03-16 Address: License: 31170 Reserve Drive 686310. City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Digitally signed by CHEERS". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number,: 418-A020016236A-000-000-0000000-0000 Registration Date/Time: 2018-03-16 10:06:14 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2018-03-16 10:06:19 Schema Version: rev 10/16