BRES2017-003078-495 CALLE TAMPICO
D
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Application Number: BRES2017-0030 Owner:
Property Address: 50655 CALLE GUAYMAS WILLIAM LAKES
APN: 770094007 79840 MEMORAIL PLACE
Application Description: LAKES/ 2,623 SF DWELLING/VB/RES-3/CLASS A-FR/13D LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $172,599.70
Applicant: Pp Contractor:
WILLIAM LAKES OWNER BUILDER
79840 MEMORAIL PLACE MAY 2 2 2017
LA QUINTA, CA 92253
CITY OF LA QUINTA
DESIGN AND DEME!-OPMENT DEPARTMENT Llc. No.:
LICENSED CONTRACTOR'S DECLARATION
Lhereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: _ License No.:
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that lam exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 ofthe Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
sub'ects the applicant to a civil penalty of not more than five hundred dollars ($500).:
as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors'. State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractors) licensed pursuant to the
Contractors' State License Law.).
fUKJ am exempt under Sec. B.&P.C. for this reason
Ll
r' e
tiDate: S 22 �� / Owner:��,
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
Date: 5/22/2017
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will mai ntain'workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number:
cert _
a ify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:` 5 — 2_Z—Z6 (?'Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE. LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and.for whose benefit work is performed under or pursuant to any permit issued
as a result of this application, the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the workbeing performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned property for inspection purposes.
Date: `ZZ-26Signature (Applicant or Agent):
Date: 5/22/2617
Application Number:' .
BRES2017 0030
Owner:
Property Address:
50655 CALLE GUAYMAS
WILLIAM LAKES
• APN:
770094007
79840 MEMORAIL PLACE
Application Description:
LAKES/ 2,623 SF DWELLING/VB/RES-3/CLASS A-FR/13D .
LA QUINTA,-CA 92253
Property Zoning:
Application Valuation:
$172,599.70
Applicant:
Contractor:
WILLIAM LAKES
OWNER BUILDER
79840 MEMORAIL PLACE
LA QUINTA, CA 92253
--------------------------------------------------------------------------------------------
Llc. No.:
Detail: LAKES / 2,623 SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH..
2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $7.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $7.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - LIBRARIES
253-0000=43200
0
$344.00
DESCRIPTION
ACCOUNT
QTY
'AMOUNT .
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT.
QTY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$17.73
Total Paid for ELECTRICAL: $43.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$25.84
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-000042600
0
$10.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$152.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$50.16
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $238.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF
101-0000-42408
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC
101-0000-42600
0..
$190.00
Total Paid for GRADING: $228.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
'$50.66
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD.
101-0000-42402
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT.
FURNACE
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE PC
101-0000-42600
0
$50.66
DESCRIPTION
ACCOUNT'
QTY
AMOUNT
VENT FAN
101-0000-42402
0
$76.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$30.42
Total Paid for MECHANICAL: $377.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2016 UPDATE
101-0000-20310
0
$1,221.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,221.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$586.32
Total Paid for NEW CONSTRUCTION PERMIT: $586.32
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-4.2600
0
$1,200.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101=0000-42600
0
$15.36
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,215.36
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE
•101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$17.73
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$228.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$228.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$25.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$15.20
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.67
Total Paid for PLUMBING FEES: $646.13
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$22.44.
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $22.44
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320
0
$1,837.44
Total Paid for TUMF - RESIDENTIAL: $1,837.44
Bin.#AD
Permit #
" 17
C�tX of, La QumLa
Btidfding 8L Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La.Quinta, CA 92253 -:(760) 777-7012
003 6 Building Permit Application and Tracking Sheet
ProjectAddrrss: Zj- 1� �V < •.O.wner'sName: .�(I\A -
kE
A_ P. Number. -1-10- — 667 � Address: -19-5+o Keµ ori P/ p,ep_
Legal Description: (j K. ( -dcity, ST, Zip: 1-1, CiV t i qP-),55
Contractor: N h Telephone:
Address: l� Project Description:
City, ST, Zip: iW 'D l L) 11/l iIj
z.
Telephone: a
State Lic. 4: City Lic. #t
Arch, Engr., Designer F
Address:g! _ o
City, ST, Zip ' -[7(,,--D �� 3
Telephoner : Y Y Construction Type: \) Q, Occupancy: 3
State Lia #: m` " _ may« ` ' :i �- Project type (circle one): a Addt'n Alter Repair Demo
Name of Contact Person: t3 Sq. Ft .*� +-I3 # Stories: 1 # Units:
Telephone # of Contact Person:-L"(g g
D ' " 3� �� ` '1 Estimated Value of Project p d
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
'Rec'd
TRACKNG
PERMIT FEES
Plan Sets
Plan Check submitted
item Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Cates.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction "
Flood plain plan
Plans resubmitted..
Mechanical
Grading plan
2" Review, ready for correctionslissue
Electrical
Subeontactor ISst
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE.,
''' Review, ready for correctionvIssue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. f4'ks. Appr
Date of permit issue
School Fees
Tota
. ■ ■ � � nt� a er tau. asraP
FEB 2 4 2017
CITY OF LA ®UINTA
COMMUNITY DEVELOPMENT
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
Date: 3/24/2017 La Quinta, CA 92253
No.: 17-00530-1 (760)771-8515
Owner: William Lakes Email:
Address: 50-655 Calle Guaymas Jurisdiction: La Quinta
City: La Quinta, CA Tract #:
Type: Single Family Residential
Lot # Street No. Street Name Sq. Feet APN
50-655 Calle Guaymas 2623 770-094-007
Comments:
JN�Fieo s
r°y coo
tt r
N BERMUDA DUNES'
RANCH0 K%AGB 2
d INDIAN
IAp 9�g y
c C fr .a
NTA 5�
o �NDtO >
Permit No.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.48 X 2623 S.F. or $9,128.04 have been paid for the property listed above and that building
permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: CC Bank of America\William Lakes
Bank Name/Recipient of Cert iicate
By Kathleen Felci
Interim Superintendent
Fee Collected/ Exempted by: Virgilio
Check No.: 1295708328
Telephone:
Funding: Residential
Certificate Fee3.D4e: .: 9,.1-28.04-;- =
Original Paymerj (s) Rec'# = 0.00 -7, _
New Payment aec'd: YJ.;'128.04 ^j
OiQ-Qnde'r: $O.C.U~
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to that the 90 -day approval period in which you may protest, he fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
APR 2 5 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
RECORDING REQUESTED BY:
Ticor Title Co.
tM au -r64,ez
AND WHEN RECORDED MAIL TO:
Mr. and Mrs. William P. Lakes
79840 Memorial Place
La Quinta, CA 92253
THIS SPACE FOR RECORDER'S USE ONLY:
Title Order No.: 00402066-993-SS1 Escrow No.: 007037 -CM
AP#: 770-094-007-6 GRANT DEED
THE UNDERSIGNED GRANTORS) DEC.LARE(S)
DOCUMENTARY TRANSFER TAX is $140.25 0 ��� D� —
[X] computed on full value of property conveyed, or
- -com utea on full valueless val""ue of lien`s or encumbrances remaining at time of sere. -
[ ] Unincorporated area [X] City of La Quinta AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Lvonne Weber, who acquired title as Lvonne Yessayian, a widow
hereby GRANT(s) to:
William P. Lakes and Joanna Lakes, Husband and Wife as Joint Tenants
the real property in the City of La Quinta, County of Riverside, State of California, described as:
LEGAL DESCRIPTION ATTACHED HERETO AS EXHIBIT "A" AND MADE A PART HEREOF
Also Known as: Vacant lot known as APN: 770-094-007-6, La Quinta, CA 92253
Dated June 28, 2016Lvonne Weber
A notary public or other
'completing this certificate verifies only the identity of the individual who signed the document to
which this certificate is attached, and not the truthfulness, accuracy, or validity of that document.
STATE OF CALIFR RNIA
COUNTY OF Krvers de
On L b! before me;_ r/" -MIA L . AIDVA-140 A Notary Public personally
appeared Vry IOF�B£�, who proved to me on the.
basis of satisfactory evidence to be the person(, whose name(,I) is/are subscribed to the within instrument and acknowledged
to me that-lie/she/they executed the same in His/her/tketr authorized capacity(i®s), and that by His/her/thok signature() on the
instrument the person(, or the entity upon behalf of which the person(?) acted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and
correct.
WITNESS my hand and official seal. CYNTHIA L. MOZtNGt)
COMMI86ton # 2043609
a Notar
Signature zy public - California.:
(Seal) ' Riverside County _
MAIL TAX STATEMENTS TO PARTY -TOWN BELOW; IF NO PARTY SHOWN, MAIL AS SHOWN
RECEDE®
APR 2 5 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Plan Submittal
Job Site
Building Permit Number:
Project Description: SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Owners Name
Number, Street, or PO Box
City, State, Postal Code
Owners Phone Number
Owners E -Mail Address
Project Managers Name
Project Managers Phone Number
Project Managers E-mail Address
Builder / Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
4/10/2017
50-655 Calle Guaymas
William Lakes `
79840 Memorial PI
La Quinta, CA. 92253
William Lakes
760-423-7237
casadelakestaaol.com
William Lakes/Owner-Builder
79840 Memorial PI
La Quinta, CA. 92253
Approx. 2,623 square feet
CityApproval By Renado Gouldlock-DECBurrtecWaste
Date of City Approval
RECEIVE®
APR 2 5 2017
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Materials To Be Discarded:
Product
Tons
Trash
10.50 Not recyclable
Product
Tons
Asphalt
0.00 Recyclable
Masonry (broken)
0.00 Recyclable
Brick/Block
0.00 Recyclable
Plaster
3.25 Recyclable
Cardboard
0.00 Recyclable
Scrap Metal
0.00 Recyclable
Commingled
0.00 Recyclable
Tile (floor)
0.25 Recyclable
Concrete
11.00 Recyclable
Tile (roof)
0.50 Recyclable
Drywall
1.25 Recyclable
Wood
4.50 Recyclable
Donated / Reuse*
0.00 Recyclable
Landscape Debris
0.00 Recyclable
*Describe Items
Totals: Recycle Trash
20.811 10.5
Projected Diversion:
66.40%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
It
Owner / Developer / Project Manager / Superintendant Date
P:'O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495, CALLS TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING &SAFETY DEPARTMENT -
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures &-Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in our name listing yourself as the builder of the property
improve ments:specified at
We are providing you with an Owner-Burlder.Acknowledgment and Info tion Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority. .
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION .
DIRECTIONS: Read and initial each statement below to signs you understand or verify this information:
LL I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. 1, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
LAA2. I understand building permits are not required to be signed .by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
(3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her.name instead of my
own.
(,AL4: I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
i.,D-S. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of -my -construction -is -at -least -five hundred dollars ($5U0)—including labor and materials, I may be considered an "employer"
under state and federal law.
lop
understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance; and contribute to unemployment
compensation for each "employee." I also understand my failure to'abide by these laws may subject me to.serious financial
risk.
LAP7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with .the intent to offer them for sale, unless all work is' performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
�. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for .any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
UX. I understand I may obtain more information regarding my'obligations as an."employer" from the Internal Revenue
Service, the United States Sma1l.Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents: I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
8--0,,,,0-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
�8. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party.legally, and '�y'`�,`��}r�cially responsible for proposed construction activity at the following address:
tA FhLI . I agree that, as the party legally and financially responsible for this proposed construction activity, I will; abide by all
applicable laws and requirements that govern Owner -Builders as.well as employers.
2. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors,
,you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner „ �'Q� Date:
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION 'OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agents) to.apply for, sign; and file. the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the.owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owners signature.
Property Owner's Signature: Date:
WM
0
CITY OF LA QUINTA SUB -CONTRACTOR. LIST
JOB ADDRESS 5d' C5"CL wLa PERMIT NUMBER OWNER - >: „BUILDEl3
This'.fbrni-sha1F he posted bit the.joh .witli'the �lildiiia•'inspection Card at, all times in. a - conspicuous -place. Only persons appearing on this list or their emuloyees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement -of work. Failure to comply will result in a stoppage of work and/or the voidance
-. __ .• . . -- -'- -" t__-_-��--- _--..__+..1 L...1.,... ,.....,,+ L..,..,.,.,.,al.,+.,.-1-t-.;,I; + ,r)n gild' ie not an arranl'ahlp. rp-,dohse •.
Of DUIIafFig pelf tll t: rUJ
COlal d1J Pucau U uauc�. an ni�v����u
uv�> i� yu. �w.. .+�.. •. .... r
r ^nr -- -
"
� Y"
_.,.,.. ..�, :
.... ... ,.�
r -►dc ClasslflCa long
T 1 t
.x :t.",.:.:.-� ...�.
w .. ..... ... >
»•sr.> Contractor r
�,,,:..>:..,.. �, �•�:.>-.
�_.. r _ , . ;�
S atb C ntracto s L i s
,.:"� 4 � �
r.,..:, ._ �., >ftisur n c� �. r-�:�
ckers C ►> >ensa ion :.c:.: 3,.
,>. z,Wa !
, s .. s r
� - —
_
Zsews `
Company Name
Classification
License Number
Exp. Date
Carrier Name
Policy Number
Exp. Date
License Number
Exp. Date''
(e.g. A, B, C-8)'
(xxxxxx)
(xx/xx/xx)
(e.g. State Fund, CalComp)
(Format Varies)=(xxlxx/xx)
(xxxx)
(xx/xx/xx)'
hRTHWOt�Kr(C
` S
l Dr,�O
12)��
! V` Ot C'.v.
l�� 1.
rCCNC�iETC (C 8) ,�
e
MING 5)
��II
63
ZD
(C
l�O'
r r
'STRUGT STEL*(C 5Y1)'
-
•
1VIASONRY {C'29) f`
�
-
F
� uME31NG-P-(:h01rr•t
l (Uwb-
Ci'
3�
LATH ALASTCR
DRYWALL. (C 3j
<HVAC (C 20)
C--
'. Z
-304 b
x
Cott"
,
>:LECTRICAL (C 10) '
�^ I
s
0.
_.
-
S C 9) �s `�'
ROOFING(
.... <...... e
SNEF7 N(ETA( (C 4$)
'INSUI A----------
-TiOlp(C 2)
SLWl�Gc D1SP (C"4.
—
CLI�/aMIC
CABINCTS fC,G) a
i ENCING
(
POOL `lC rg), a
_
YOUNG
ENGINEERING W
a
V 0 r 8 -1n..
........ .. . .
.1 1 •t f
e
v - a
` Letter of Transmittal
To: City of La Quinta Today's Date:
5-4-17
78-495 Calle Tampico City Due Date:
-
5 -9 -17 -
-9 -17 -La
La Quinta, CA 92253 -Project Address:
50655 Calle Guaymas
Attn:. MARY - Plan Check #:
BRES2017-0030 _
Submittal: 0 1 St
❑
4th
0 2nd.
❑
5th
❑ 3�d
❑
Other:
We are forwarding: By Messenger ❑ By Mail
(Fed Ex or UPS) ❑ Your Pickup
Includes: Descriptions: Includes:
# Of Descriptions:
•
Copies: '
❑ Structural Plans
V❑
Revised Struct. Plans
❑ Structural Calculations
❑
Revised Struct. Calcs
D 1 Truss Calcs -
O
Revised Truss Calcs
❑ ,Soils Report - Update
❑
Revised Soils Report
Structural P/C Responses •'
O
'Approved Structural Plans
1 / Comments
1
D 1 Redlined Structural Plans
1 Approved Structural Calcs
D 1 Redlined Structural Calcs
❑
Approved Truss Calcs-
O , 1 Redlined Truss Calcs
❑
- _ Approved Soils Report
• ❑ Redlined Soils -Reports
❑
Other:
Comments: Structural content is approvable once address is provide on truss cover sheet and the EOR provides letter of
review of trusss calculations or a shop drawing stamp on truss calculation package.
Transit Per Diem=
Admin Time = 0.25 hrs.
Structural Engineer/Principal Review Time = 0.0 hrs.
Plan Review Engineer Time = 1.0 hrs.
This Material Sent' for,:
❑ Your Files
.Per Your Request
❑ Your Review
❑
.Approval
❑ Checking
❑
At the request of:
Other: ❑
[ �, ®r
_ow—`,,V
By: Joe Venuti
Office: - El (760) 772-5107 s MAY 10 2017
Other: _0 LQPC@VALUENGR.COM CITY OF (4
QUINTA
COMMUNIly DEVEL9P4,NT
RT4500 SERIES
TRADITIONAL
EXCLUSIVE FEATURES
Available in 36" 42" and 50" models
Massive smok-2 dome for reliable operation
Fully insulatec< f rebox for irn_reased performance in colder climates
Refractory panels in two patterns with integrated ash lip
Heavy duty cast iron log graze with rugged forged andirons��
Midden asp cramp with pull mg
Easy access damper control
Includes rnesr fire screens
Dual (left ha-d/right hand) outside air kits ova fable for maximum performance
Durable text -red powder ccat finish
Uses IHP 12 DrA (1700) doutle wal air cooled wood burning chimney
6Uses IHP 12 H— ;2100) heavy gauge double wail air cooled wood burning chimney, recommended for cold climates
(required for Canada)
�A �20 year limited warranty �_..._..�.�._,..�.�.�.
r.'4tT1542 f replace and its large heavy our.g co ,.r'-,te .anc rugged ?o 9e04 < rtdirorS
(Required)
Choose refry -tory penels in stacked or herringbone patterns.
White Stacked Whi•e HeFringbone
GLASS DOORS
at '
Tempered : -fold glass doors are expertly .rifted and firthed in three options.
Platinum
Brushed Brass
Black
Maintain 1 '/Z'
Clearance at Sides and
Back of Fireplace
1 '/Z' Clearance
Not Required at
F Nailing Flanges
E
�0�
WRT4536 WRT4542 WRT4550
_..-._._._...._........._......._.. ... — --- --.-----.._._............._.....__..--..-_.-.._._._..._......._.._--
0 45-1/4' 51-1/4' 59-1/4'
............ _-_-- ......... ............. .......
- - - -- - -- -..._._......_... - ..__....__........
E 86-12' 92' 100'
F 61' 65' 71'
I— S —1
WRT45M WRT492 WRT4550
G 36' 42' 50'
H 45-1/8' 51-1/8' 59'
1 29' 30-12' 38-12'
1 26-5/8' 29' 28-12'
K 30' 30' 30'
L
49'
49'
49'
M
FLAT
WALL FRAMING SPECIFICATIONS
67'
N
APPLIANCESPECIFICATIONS
10.12'
10-12'
0
............ ...... - ..........
9-12'
_.__. —
9-12'
9-12'
P
3-12'
3.12'
3-12'
Q7-1/4'
........_............_
Uses IHP •.
8-12'
8-12'
R
11'
13'
13'
Wood Burning Chimney Pipe
7B_�'.
III
\M
,
r] /,I I�TI I
0 �i 'I
i ..
IOUTSIDEAIR
ACCESS
GAS LINE
1
,,ACCESS
illl
,
Maintain 1 '/Z'
Clearance at Sides and
Back of Fireplace
1 '/Z' Clearance
Not Required at
F Nailing Flanges
E
�0�
WRT4536 WRT4542 WRT4550
_..-._._._...._........._......._.. ... — --- --.-----.._._............._.....__..--..-_.-.._._._..._......._.._--
0 45-1/4' 51-1/4' 59-1/4'
............ _-_-- ......... ............. .......
- - - -- - -- -..._._......_... - ..__....__........
E 86-12' 92' 100'
F 61' 65' 71'
I— S —1
WRT45M WRT492 WRT4550
G 36' 42' 50'
H 45-1/8' 51-1/8' 59'
1 29' 30-12' 38-12'
1 26-5/8' 29' 28-12'
K 30' 30' 30'
L
49'
49'
49'
M
67'
67'
67'
N
10-12'
10.12'
10-12'
0
............ ...... - ..........
9-12'
_.__. —
9-12'
9-12'
P
3-12'
3.12'
3-12'
Q7-1/4'
........_............_
............ ............... ........ _ ..............
8-12'
8-12'
R
11'
13'
13'
S 15-1/4' 17' 17'
IMPORTANT NOTES:
As with any fireplace, this appliance is extremely hot during operation. Read and understand all operating
instructions before using this appliance. For further information, consult your dealer.
On the Cover: `Jt/RT4542 fireplace t ith White Herringbone Refractor,/
Local conditions, such as elevation, wind, went configuration and choice of fuel will affect overall appearance
Panels of the fire and heating performance. Performance can also vary with home design and insulation, climate.
condition and type of fuel used, appliance location, bum rate. accessories chosen, chimney installation and how
the appliance is operated.
Diagrams, illustrations and photographs are not to scale—consult installation instructions. Product designs,
materials, dimensions, specifications, colors and prices are subject to change or discontinuance without
notice.
u AV F lertov
® 2017 Innovative Hearth Products
785353M 01/17
Visit us online
o
SuperiorFireplaces.us.com
c us
Report NF09-095
Boral Roofing
Build something great'"
40
Saxony° 900
Country Slate
At 3" minimum headlap, 85 field files
will cover approx. 100 square feet of
roof area.
Unique beveled edges
precisely define each
roof the for a staggered
appearance.
Compliant with
Caltornla Ttle 24, 2013
Aged SRI requir6mrer t.
Calculated Aged .rare sr
Sea Peart Blend
1FECY4070
GRRG Rased Froduct - 0942-0186; Rett .19 /Aged Ref -1 E,,i:.91 % SR;: 18 I Agec SRI:,.,,%)
Bronze Pearl Mend
1 FECY03J'i
GRRO Rated Prcfuct - 0942-0187; Ref; .2 6 /Aged Ret. Emi:.91 r' SRI: 27 i Ageu SRI:
S okey Topaz Blend
1 FECY3181
GRRG # 09-42-01911' Ref: .21 /Aged Ref 1 E ^<:.93 / SRI: 22 i Aged SRI :#
The pnnt8d colors shown in this CIA S,hP,et rrIaV vary frOm 4RChIal 3WIiLable. file �Oiors.
,
•
r
„,
• � v4.4
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R -PRF -01
Project Name: Single Family Residence Calculation Daterrime: 13:40, Tue, Apr 11, 2017 - Page 1 of 9
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence.ribd16x
GENERAL INFORMATION
- -
01
Project Name Single Family Residence
04
'
02
Calculation Description Tille 24 Analysis
Energy Use (kTDV/ft2-yr)
03
Project Location 50655 Calle Guaymas
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2017 '
06
Zip Code
07
Compliance Manager Version BEMCmpMgr 2016.2.1 (695)
08
Climate Zone CZ15
09
Software Version EnergyPro 7.1'
t0
Building Type Single Family
11
front Orientation (deg/Cardinal) 90
12
Project Scope Newly Constructed -
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 2623
15
Number of Zones 1
16
Slab Area (ft2) 2623
s'''` y ;..17.
Number of Stories 1
18
Addition Cond. Floor Area Na
, F�;y<ta.: r 'j`; :'"ti`19i •.
Natural Gas Available Yes '
20
Addition Slab Area (112) rt/aY:?;
Glazing Percentage (%) 16.3
COMPLIANCE RESULTS
1'`'`'d`
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CECapproved HERS provider.
03
This building incorporates one or more Special Features shown below
CjOp655 VAY4kS
Registration Number. PRF17-00160384 Registration DaterTme: 04/11/2017 16:19 HERS Provider. CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version'- CFl R-03032017-695 Report Generated at: 2017-04-11 13:41:03
lop?
2017
FDATIE
F LA QUINTA
G & SAFETY DEPT.
'OOVED'
ONSTRUCTION
.SOI BY
ENERGY USE SUMMARY
04
a05
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
0.24
3.06
-2.82
-1175.0%
Space Cooling
72.44
64.06
8.38
11.6%
IAQ Ventilation
0.99
0.99
0.00
0.0%
Water Heating
5.01
10.54
-5.53
-110.4%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
78.68
78.65
0.03
0.0%
CjOp655 VAY4kS
Registration Number. PRF17-00160384 Registration DaterTme: 04/11/2017 16:19 HERS Provider. CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version'- CFl R-03032017-695 Report Generated at: 2017-04-11 13:41:03
lop?
2017
FDATIE
F LA QUINTA
G & SAFETY DEPT.
'OOVED'
ONSTRUCTION
.SOI BY
I
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: Single Family Residence Calculation Date/Time: 13:40, Tue, Apr. 11, 2017 Page 2 of 9
Calculation Description: Title 24 Analysis 'Input File Name: Lakes Residence.ribdl6x
' ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC)..A score of zero represents the energy performance of a building
that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6
(such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under
Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and.renewable
energy can both be seen
_ EDR of Standard Design
EDR of Proposed Design
EDR Value of Proposed PV '
Final EDR of Proposed Design
_ 51.4
51.3
0.0 -
51.3
❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin;(CALG een 44.203.1.22) and Oil verification prerequisite.
❑ Design meets Zero Net Energy.(ZNE) Design Designation requirement for Si1.ngile`0 iii. in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including onsite
photovoltaic (PV) renewable energy generation sufficient to achieve a final,Energy Design Rating (EDR) of zero or less. The PV System must be verified.
REQUIRED SPECIAL FEATURES `"!'l 'ijM""="""!:'{''
»w:s?i.
' Ya�3 .mv .
The following are features that must be installed as condition for meeting the modeled ene'rgyrperfortna«ynce for this computer analysis.
• Cool roof :v?:"'•"
Window overhangs and/or fins
Pipe insulation, all lines
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a ceNfied HERS'RaieFlas a condition for ineeGng the modeled energy performance for this computer analysis. Additional detail is
Provided in the building components tables below.
Building -level Verifications: .. •<, a. x;.: ::.cE _;.:•: s;,-:< :•:;,:.; :•,..:::,:::c.y -
• IAQ mechanical ventilation
Cooling System Verifications: '
• Minimum Airflow
• Verified EER
Verified SEER
• Refrigerant Charge
Fan. Efficacy Watts/CFM
HVAC Distribution System Verifications:
Duct Sealing
• Low -leakage Air Handling Unit '
Domestic Hot Water System Verifications:
None —
Registration Number. PRF17-00160384 Registration Date/Time: 04/11/2017 16:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-03032017-095
HERS Provider. CHEERS
Report Generated at: 2017.04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence - Calculation Date/Time: 13:40, Tue, Apr 11, 2017
Calculation Description: Title 24 Analysis Input File Name: Lakes Resi6ence.ribdl6x
CF1 R -PRF -01
Page 3 of 9
BUILDING - FEATURES INFORMATION
.,-..'�' fed:•:
Ot 02 `'03 ' �`• "• �
a.a. '-3%; :'.:i::
`'• 04` ' �' � .> OS 06 07 08
Name Construction Type
' 01
Attic Whole House Attic RoolWhole House Ventilated
02
03
04
05'
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Single Family Residence
2623
1
3
' 1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area '
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Whole House
Conditioned
Whole Housel
2623
9
DHW Sys 1
OPAQUE SURFACES01
K;,l�r •�,,-z
02
:�iO3r::, .�:r�;4.c - 04
OS
06
07 08
Name
Zone
:zsxa:..f,•;..;g:u-�.
Constructioh'•, i'° -� Azimuth
Orientation
Gross Area (1`12) Window & Door Area (ft2) rift (deg)
Front Wall
Whole House
R=2�1`.VYall'1�;;;;� • 90
Front
500
78 90
' Left Wall
- Whole HouseR-21
Wall •. 0
Right
300
97 90
f Rear Wall
Whole House
R-21 Walks 270
Back
650
167 90
Right Wall
Whole House
R-21 Wall - 180.
Left
300, 85.9808 90
Roof
Whole House,
R-38;Roof Mm.
2623
'sem-u. i� iE-._. ' 1". . S ffi_ ...- A
ATTIC
.,-..'�' fed:•:
Ot 02 `'03 ' �`• "• �
a.a. '-3%; :'.:i::
`'• 04` ' �' � .> OS 06 07 08
Name Construction Type
Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Whole House Attic RoolWhole House Ventilated
0 0.9 0.9 Yes Yes
Registration Number. PRF17-00160384 Registration DateRme: 04/1111201716:19 - _ HERS Provider. CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CFIR-03032017-695 Report Generated at: 2017.04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DaterTime: 13:40, Tue, Apr 11, 2017
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence. ribd I 6x
CF1R-PRF-01
Page'4 of 9
FENESTRATION f GLAZING
O1
02
03 04-
05
'06
07
08
09
10 .
Name
-Type
Surface (Orientation- Azimuth) Width (ft)
Height`
(ft)
Multiplier
Area
(ttZ) -
LI -factor
SHGC
Exterior Shading
Window
Window
Front Wall (Front -90) 4.0
2.0
1
8.0
0.40
0.32
Insect Screen (default)
Window 2
Window
Front Wall (Front -90) 6.0
5.0
1
30.0
0.40
..0.32
Insect Screen (default)
Window 3
Window
Front Wall (Front -90) 8.0
5.0
1
40.0
0.40
0.32
Insect Screen (default)
Window 4
Window
Left Wall (Right -0) 6.0
2.0
1
12.0
0.40
0.32
Insect Screen (default)
' Window 5
Window
left Wall (Right -0) 5.0
5.0
. 1 !
25.0.
0.40
0.32
Insect Screen (default) .
Window 6
Window
. Left Wall (Right -0) 6.0
_ 5.0
1
30.0
0.40
0.32
Insect Screen (default)
Window 7
_ Window
Left Wall (Right -0) 6.0
5.0
1
30.0
0.40
0.32
hued Sween (default)
Window 8
Window
Rear Wall (Back-270j�-,*"
8.0
1
24.0
0.40
0:32
Insect Screen (default)
Window 9
Window
Rear Wall (Back -276)' '�9 2:5
5.0
5.0
1
12.5.
0.40
0.32
Insect Screen (default)
Window 10
Window
- rs '<1 .' .
Rear Wall (Bade -270) <g�. � '< -r ,- Y2,5
5.0
1
12.5
0.40
0.32
Insect Screen (default)
Window 11
Window
Rear Wall (Back -270) { t K''; 6.0
5.0
.1
30.0
0.40
0.32
Insect Screen (default)
Window'12
Window
Rear Wall (Back -270) ;,.,, 6.0
8.0
1
48.0
0.40
0.32
.Insect Screen (default)
Window 13
Window
Rear Wall (Back -270)8.0
5.0
1
40.0
0.40
0.32
Insect Screen (default)
Window 14
Window
Right Wall (Left -180) 2.0
4.0
1
8.0
0.40
0.32
Insect Screen (default)
Window 15
Window
Right,Wall (Left; 80)`. 4:
0
1
20.0
0.40
0.32
Insect Screen (default)
Window 16
Window
Right Wa0 (Left' -X180), t4"" L°` 4.0 Y''
!V0
1
20.0
0.40
0.32
Insect Screen (default)
Window 17
Window
Right Walh(Left-180)..1
0.694
.30.0
0.40
0.32
Insect Screen (default)
Window 18
Window
Right Wall (Left -180) 4.0
2.0
1
8.0
0.40
0.32.
Insect Screen (default)
Registration Number. PRF17-00160384 Registration DateTme: 04/11/2017 16:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-03032017-695
i
HERS Provider: CHEERS
Report Generated at 2017-04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Family Residence a Calculation Datelrime: 13:40, Tue; Apr 11. 2017 Page 5 of 9
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence.ribdl6x
OVERHANGS AND FINS
01
02
03
04 1
05 06
07
08 1
09
10 -
11
12
13 '
14
Overhang
Left Fin
Right Fin
f Window
Depth.
Dist Up
Left
Extent
Right
Extent Flap Ht. -
Depth
Top Up
DistL
Bot Up
Depth
'
Top Up
Dist R
Bot Up
Window
2
0.1
2
2 0
0
0
0
0
0
0
0
0
Window 2
2
0.1
2
2 0
0
0
0
0
0
0
0
0
t Window 3
2
0.1
2
2 0
-0
0
0
0
0
0
0
0
Window 4
2
0.1
2
2 0
0
0
0
0
0
0
0
0
Window 5
2
0.1
2
2 0
0
0
0
0
0
0
0
0
Window
2
0.1
2
2 0,.
0
0
0
0
0
0
D
0
Window?
2
0.1
2
2-
0
0
0
0
0
0
0
0
.Window8
2
0.1
2
2`;.,.'0,°t;tk;;'
0
0
0
0
0
0
0
0
Window 9
2
0.1
2
2 erg; ;£p *' t
0
0
0
0
0
0
0
0
Window 10
2
0.1
2
2 `.`x' y O i,k
�€
0
0
0
0
0.
0
0
0
Window 11
2
0.1
2
2 's0>':
0
0
0
0
0
0
0
0
Window 12
2
0.1
2
2 b
0
0
0
0
0
0
0
0
Window 13 .•
2
0.1
2
2 0
0
0
0
0
0
0
0
0
Window 14
2
0.1
2''y
2; '- j "" 0'Hr"`"
'_..
0
0
0
0
0 -
0
0
o.
Window 15
2
0.1
2 -
a 2 -0`^°�
d '�'0
0
0.
0
0
0
0'
0
Window 16
2
0.1
2,
2 .. '0.
._;:•0_.,.','0:�:...r
0
0
0.
0
0
0
0
0
Window 17
2
0.1
2�-- 2.::•:
0
0
0
0
0
0
0
Window 18
2
0.1
2
2 0
0
0
0
0
0
0
0
0
Recislration Number. PRF17-00160384 Registration DateTme: 04/11/2017 16:19
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-03032017-095
HERS Providei: CHEERS
Report Generated at: 2017.04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Family Residence Calculation DatefTime: 13:40, Tue, Apr 11, 2017 Page 6 of 9
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence. ribd I 6x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
- 04
05
06
07
Construction Name
Surface Type
Construction Type
'
Framing
Total Cavity
R -value
Winter Design
U -value
Assembly Layers
Attic RoofWhole House
Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.
none
0.644
Cavity/Frame: no insul. /2x4 Top Chrd
Roof Deck., Wood Siding/sheathing/decking
Roofing: Light Roof(Asphalt Shingle)
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069'
Inside Finish: Gypsum Board
Cavity/Frame: R-21 /2x6
Exterior Finish: 3 Coat Stucco
'
R-38 Roof
Ceilings (below--
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R'38
0.025
• Inside Finish: Gypsum Board
Cavity/Frame: R -9.1/2x4
Over Ceiling Joists: R-28.9 insul.
SLA13 FLOORS
Nom'.
01 02^^03. '�`�' 04 05 06 07
.M w:
s...# .�� zpr,
Name ZoneAiea�(ftZ)C'.•.e §'r1;r , Perimeter (ft) Edge Insul. R -value 8 Depth Carpeted -Fraction Heated
Slab -on -Grade Whole House 2623u: y v ;.' 15 None 1 No
BUILDING ENVELOPE -HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation' k - .,,-Building Envelope Air Leakage CFM50 -
Not Required Not Required;t Not Required —
WATER HEATING SYSTEMS ) : ;;,, ;.• , „
• 01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 (2) 2 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Name
Heater
Element Type
Tank Type
Number
of Units
Tank
Volume
(gal)
.Energy
Factor or
Efficiency
Input
Rating/Pilot
Tank Insulation
R -value
(Int/Ext)
Standby Loss I
Recovery Eff
NEEA Heat Pump Type
Tank Location or
Ambient
Condition
DHW Heater 1
Gas
Small Storage
2
40
0.63 EF
37000 Btu/hr
n/a
n/a
n/a
n/a
Registration Number. PRF17-00160384 Registration DateTme: 04/11/2017 16:19 HERS Provider. CHEERS
CA Building Energy Efficiency Standards = 2016 Residential Compliance Report Version - CF1 R-03032017-695 Report Generated at: 2017-04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Single Family Residence Calculation Date/Time: 13:40, Tue, Apr 11, 2017 Page 7 of 9
Calculation Description: Title 24 Analysis ' Input File Name: Lakes Residence.ribdl6x
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name'
Whole Housel
Other He System
ystem Cnd ooling Heating Component 1
Cooling Component 1
HVAC Fan.1 '
Air Distribution System 1
HVAC - HEATING UNIT TYPES
01
- 02
03
04 -
Name
System Type
Number of Units Efficiency
Heating Component 1
CntdFumace
2
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 tt
1`Y 04
05
06
07
08
Name
System Type
Number of Un
a,; .:
,�'' Efficiency
SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SpIRAirCond
•+'s
2 't
+ . '
12 a '.
16
Not Zonal
Single Speed
CoolingComponent
p
1 -hers -cool
HVAC COOLING -HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow.
'"' 43 Airflow Tang_ et
"`rifiedEER
_Ve
Verified SEER
Verified Refrigerant
Charge '
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
HVAC -DISTRIBUTION SYSTEMS
01
02
03 04 05
06
07
Name
Type
Dud Leakage Insulation R -value Duct Location
Bypass Dud
HERS Verification
Air Distribution System 1
DuctsAltic
Specified Lower Leakage
Target
6 Attic
None
Air Distribution System
1 -hers -dist
HVAC DISTRIBUTION -HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Dud Leakage
Target I%)
Verified Duct
Location
Verified Duct
Design
Buried
Duds
Deeply Buried
Duds
Low4eakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
. Required
Registration Number. PRF17-00160384 Registration DateRme: 04/11/2017 16:19 HERS Provider. CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-03032017-095 Report Generated at: 2017-04-11 13:41:03
- r
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DaterTirile: 13:40, Tue, Apr 11, 2017
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence.ribdl6x
CF1R-PRF-01
Page 8 of 9
HVAC -FAN SYSTEMS
'
01 02
03
04 '
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
Name Type
Pan Power (Watts/CFM)
HERS Verification
HVAC Fan 1 Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC FAN SYSTEMS -HERS VERIFICATION
'
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
IAQ (Indoor Air Quality) FANS
_
01
02
04
05
06
L- Dwelling Unit
IAQ CFM
IAQ Watts/CFM: . •
IAQ Fan Type
UIQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
56
':025(s • '
Default
0
Required
jt'' P
• Y�'z
Registration Number: PRF17-00160384 Registration Date/rime: 04/11/2017 16:19 •- HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 ResidenUal Compliance ' Report Version - CFt R-03032017-095 Report Generated at: 2017-04-11 13:41:03
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Single Family Residence Calculation DateMme: 13:40, Tue, Apr 11, 2017
Calculation Description: Title 24 Analysis Input File Name: Lakes Residence. ribd 1 6x
CFI R -PRF -01
Page 9 of 9
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Joan Hacker
Joan Hacker
Company.
Signature Date:
Joan Hacker
04/11/2017
Address: -
CEA/HERS Certification Identification (If applicable): .
72875 Fred Waring Drive
City/Stale/Zip:
Phone:
Palm Desert, CA 92260
760-345-1352
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify lhe'following under penalty of perjury, under the laws of the State of Celifomia
1. 1 am eligible under Division 3 of the Business and Professions Code to acceptrespons�bddy tor�lhe b' itding design identified on this Certificate of Compliance.
2. 1 certify that the energy.features and performance spec ptions identified orvthis ,Certifipte;of Complianee conform to the requirements of Title'24, Part 1 and Part 6 of the California Code of
Re ulations. t •
9 .y x z n h �a ,.
consistent with the information provided on other applicable compliance documents,
,,. The building design features or system design features identified on thisCertificete of�Compllance:are
worksheets, calculations, plans and specifications submitted to the enforcement agency;forapproval wiinformationthis building permit application.
..,:x�:
Responsible Designer Name: :' v�
Responsible Designer Signature:
loan Hacker
Joan Hacker
Company: o as v rr
Date Signed:
.loan Hacker
Address:
72875 Fred Waring Drive
License:
City/State/Zip:
Phone:
Palm Desert
, CA 92260 760-345-1352
Digitally signed by CHEERS". This digital signature is provided in order
to secure the content'of this registered document and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number. PRF77-00160384 Registration Date/Time: 04/11/2017 16:19 HERS Provider. CHEERS
Report Generated at: 2017-04-11 .13;41:03
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-03032017695
4 '
r