Loading...
BMCH2017-018878-495 CALLE TAMPICO CtIv 0: 0 'i �NMUCl/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0188 Property Address: 50825 CALLE GUAYMAS APN: 770102006 Application Description: ODELLE / HVAC CHANGE OUT - (2)14SEER/81AFUE SPLIT SYSTEMS Property Zoning: Application Valuation: $33,000.00 Applicant: ALL KNIGHT HEATING & AIR CONDITIONING IN P O BOX 5232 LA QUINTA, CA 92248 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and ofessions Code, and my License is in full force and effect. License Class: C20 License No.: 771254 Date: �J �/ , �� / Contract OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.): I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addres VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: DEBRA ODELLE 50825 CALLE GUAYMAS LA QUINTA, CA 92253 Contractor: ALL KNIGHT HEATING & P 0 BOX 5232 LA QUINTA, CA 92248 (760)772-4947 Llc. No.: 771254 FM G� L. L ; �. 11 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the worjf for which this permit is issued. ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: NORGUARD INSURANCE COMPANY Policy Number: ALWC824024 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person, in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the bor Code, I shall forthwith comply with those provisions. (�/ Date: — 11 —/7 Applicar>Icf_ � �— WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to; and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to e upo a above- mentioned property for inspection purposes. 2 r Date: _ Signature (Applicant or Agen , Date: 5/19/2017 Application Number: BMCH2017-0188. Owner: Property Address: 50825 CALLE GUAYMAS DEBRA ODELLE APN: 770102006 50825 CALLE GUAYMAS Application Description: ODELLE / HVAC CHANGE OUT - (2)14SEER/81AFUE SPLIT.SYSTEMS LA QUINTA, CA 92253 Property Zoning: ., Application Valuation: $33,000.00 Applicant: Contractor: ALL KNIGHT HEATING & AIR CONDITIONING IN ALL KNIGHT HEATING & AIR CONDITIONING IN P 0 BOX 5232 P 0 BOX 5232 LA QUINTA, CA 92248 LA QUINTA, CA 92248 (760)772-4947 Llc. No.: 771254 Detail: HVAC CHANGE OUT - (2)14SEER/81AFUE SPLIT SYSTEMS. DOUBLE FEES AS WORK WAS STARTED WITHOUT PERMIT. CARBON MONOXIDE.ALARM (S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:- $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT- SPLIT -SYSTEM PC 101-0000-42600 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-4266o..' 0 $76.00 Total Paid for CHANGEOUT: $456.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 .$96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Ci y Qwnta SES*wDmdon P.O. eox ��o+f ?�49� cae T=VkD , his a QM14 CA, W.V W.V. (7 m-IDrz 8Trac ft. Sheet _ LU • Atm ` � V ��. �,� � , A P. Numbest . SL ZIF —.G l : Addi+ese~ Tdellbaam A6 t AnisyBo�D�= . : Address Tekgho= St Lic# t�'RCe deaoeX liar Add'aOwR** DOW A NffiaofCOamet /� S% t- i• 90 W% VWM ESi"M U—M .. �TVACMW Igo �l�Ji� p/!ls�ti Troucdm cs�eiCMdadrer�o. FipOa jl�Sl Zrq i i dMCMladPO p�sl!!1 2A In m A Imo CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning`Systems (formerly. CF-iR-ALT HVAC) (Page.1 of 3) Project Name: Odelle Date Prepared: 2017-05-19 A. General Information CFIR-ALT 02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CFIR=ALT-02 document for each dwelling unit. 01 Project Name Odelle 02 Date Prepared 2017-05-19 03 Projed1ocation 50825 Calle Guaymas Road 04 Building Type Single family O5 CA City to Quinta 06 Dwelling Unit Name Odelle. �07� Zip Code 92253 'J.D.welling-Unit.Conditioned 08 �Is'the SCI . __..__ .. t;.,t �.. Floor Area (ftZ) SCS stem Y CFA `served system a Y.. refri erant; g Installing new SC g Number of Space Installin g 09 Climate Zone 35 _ 10 Conditioning (SC) Systems in 2 containing system more than 40..: entirely new this Dwelling Unit: ,rt'.r- - Fri !.r"'".. .� S 1...,_, l:i..-...., 1-1-11-:._ rr., " 3r. B.Space Conditioning (8C) System Information , cj, Ol 02 03' �' 04' �.. 05 �'06 .,07„ U8 M 09 10 ... ;. .. �Is'the SCI . Installi`:' t;.,t �.. SCS stem Y SCS stem Y CFA `served system a Y.. refri erant; g Installing new SC g Installing g Installin g Instali n g' Identification or Location or Area by this SC ducted_ containing system more than 40..: entirely new entirely new Name Served System (ft2): system? component? components? feet of ducts? duct system? SC system?' Alteration Type System 1 living area 1200 Yes Yes Yes No, No No Altered space conditioning system- System.2 sleeping area 1200 Yes Yes Yes No No No Altered space conditioning: system C. Extension, of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020167495A=000-000-0000000-0000 Registration Date/Time: 2017-05-19 08:56:09, HERS Provider: CalCERTS CA Building Energy Efficiency Standards'- 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-05-19 08:55':S9 Schema Version;'reV 10%i6 CERTIFICATE OF COMPLIANCE CF111-ALT-024 Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC)' jPage 2 of"3) D. Altered Space Conditioning System (Sections 150.2(b)1E and.F) 01 02 03 04 05 06 .07 08 09 10 11 .12 Heating Cooling System Heating Altered Heating Minimum. Altered Cooling Minimum Required New or Identification System, . Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Dud or Name Type :Components Type Value System Type Component sType Value Type Duct Length R -Value Central gas All new: Central split All new This field or This field or System 1 furnace heating AFUE • 81 AC,components cooling SEER 14 Setback section is not section is not components applicable applicable Central: gas All new Central split All new This field or This field or System 2 �. `.� ---furnace--- heating �--_- _ ;,AFUE 81 AC— :� cooling SEER 14 Setback section is not section is not • components �`! com`ponents-""'"""`--' -""" -'`-'• --"T--�'---- — --___---- --applicable--- --applicable•-- Required Documentation: ' ' CF2R-MCH-01-E -`Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return-air.ducts or plenums:. R6 (CZ 1-10,.12 and 13) and R8 (CZ 11 and,14-16) MR and.CF3R-MCH-20-H'- Duct Lea kage.Test required when heating;or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced; -Leakage rate compliance: <_ S% or <=',10%leakage to outside or seal all acc ss`ible leaks. CF2R and. CF3R-MCH-25 H Refrigerant Charge venficationrequired when refrigerant contamin components are Installed or altered'(applicable in CZ.2, 9-15 .. CF2R and CF3R=MCH-23 Airflow Rate >- 300 CFM, per ton regwred when MCH � ' - 5 is required. Excen I Z)f Ductts stems re istered with HERS provider as previous sealed are exem t fro . systems, � P p y p rn'MC1120-Duct Leakage Testing requirements ' - Heating -only systems and Air Handler Furnace changes do' not regwre:verlfiaation qui e. Flow MCH -23 or Refrigerant Charge MCH=25. 4.ofAir -Existing duct systems constructed insulated or sealed with asbestos are,exempt'from MCH=20 Duct -Leakage,T.esting.requltements. !f V' ; E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 1S,0.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project.. F.. Entirely New or Complete Replacement Space Conditioning System. (Section 150.2(b)1C) This section, does not apply to this project. Refistration Number: 217-A02016749SA7000-000-0000000-0000 Registration Date/Time: 2017-05-1.9 08:56:09. HERS Provideri:CaICERTS CA Building Energy El iciency Standards - 2016 Residential Compliance. Report Version: 2016:1.005 Report Generated: 2017-05=19 08;55:39' Schema.Version; rev.10/16 'CERTIFICATE OF COMPLIANCE CF1R-ALT-027E Alterations to Space Conditioning Systems (formerly CF4R-ALT-HVAC) (Page 3 of.3) Documentation Author's Declaration Statement 1. 1. certify that this Certificate of Compliance documentation Is, accurate and, complete. Documentation Author Name: Documentation Author Signature: Knight, April Company: Signature Date: ALL KNIGHT HEATING & AIR CONDITIONING 2017-05-19 08:56:09 Address: CEA/ HERS Certification Identification (if applicable): P 0 BOX 5232 LA QUINTA CA 92248 Phone: 760-772-4947 Responsible Person"s Declaration statement I certify the following under penalty of perjury, under the laws -of the State of California: 1 1.The information provided on this Certificate,of Compliance is true and correct. 2 1 I,arn eligible under Division 3o the Bu'sineis-,zind Pr6fesslo-n`$�- Code to accept responsibi lity: for.. the building design or system design identified.;on this Certificate, of. Comp.1 ian ce, (rqsponisible designer): 3. That the energyfiaivres and performance specifications, materials, � compon I e I nt. s, andman6fattureddevices for the building'design;qr system ,design identified on this Certificate of Complianceconform io the. requirements ofrii:14.24,, Part 1and-Part 60fIrie'callfornii dode,ofkireu'IaMons. io p documents,: ts 4. The building design features or system design features identified. orjUis,Certificatelbf Co Olxa sr. ce are consistent i 'I r at' n. rovid d her, applica bI6'tohrpI lance d cum nts,,workshee' 09 hbuilding tr U, calcul tions:, Olans'and: specifications s6biinitted to the Porcerneftagency for:ap it ihis perapplication: .proval -avai6ble'w'llkh thei Al, In e s;is u thje�buil i a 't 5. 1 will ensure that a registered copy o(i.his,C&riific�jt��oi,(OTP!Iance shjIj.,4e:madhe d i for and vpllable�tq, he"inforcement agency for all applicable: :I'n,spqciion*s..l understand :that a registered copy ofthis i Icate of CojnplIancejsrequjred to be Included with 'the,dqqc ntation0e,buil er provides to the building owner,at occupancy. p pesigner Name: V Resppnsibl . s Respons'16ie Designer Signature: Knight, April rd' Company: ALL kN'IdH-r HEATING' &. AIR CONDITIONING Pate Signed: :20.17-05-19 08:56:09, Address: License: P o Bb)(5232 771254 .City/State/Zip:' Phdhei, LkO.0 I NTA CA 92248 760-772'-494-7' Digitally signed byCaICERTS- TJ is Oigi!al,signatuie.is proWded in order to secure the content of this registered document; and in no way implies. Registration Provider responsibility. for the accuracy of the information: Registration Number: 217-A020167 495A-..000 Registration Date/Time: 20117-05w119 08:56.:09 HERS Provider: CaICEM .CA Building. Energy Mciency-Stanclards - 2016 Adsidential,C . ompliarim Report Version -'2016.1.005 Report Generated: 2017-05-11 0-8-5539, S.chema Version:: rev10/16