Loading...
BRES2017-0014Twit 4 4 Q91Ar6j 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2017-0014 Property Address: 44650 NN HARLAND DR APN: 604231016 Application Description: VILLA RESIDENCE / HVAC 8gi �IOTa,WATER HEATER Property Zoning: Application Valuation: $27,612.00 Applicant: FEB. 0 7 2017 IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 CITY DESIGN ANDEVELOPMENIT DEP ARl"MENI' LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20. C36 License No.: 686310 Date: li Contractor' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Add VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/7/2017 Owner: JOEY VILLA 44650 N HARLAND DR LA QUINTA, CA 92253 Contractor: HARRISON ENTER'?RISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS, CA 92276 (760)343-7488 LIC. No.: 686310 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700of the Labor Code, for the performance of the work for which this permit is issued. �I have and will maintain workers' compensation insurance, as, required by Section 3700 of the Labor Code, for the perfornance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5031658 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so Es to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3:00 of the Labor Code, I shall forthwith comply with those provisions. e Date: Z4il 11 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMIN.>L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FORIN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on thisapplication. 1. Each person upon whose behalf this appliotion is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellbtion. I certify thatl have read this application and stc–te that the above information is correct. I agree to comply with all city and county ordirances and state laws relating to building construction, and hereby authorize representalves of this city to enter upon the above-mentioned property for inspection purpases. C� a Date:—J-7 Signature (Applicant �x Agent): tri �2�—� Date: 2/7/2017 Application Number: BRES2017-0014 Owner: Property Address: 44650 N N HARLAND DR JOEY VILLA APN: 604231016 44650 N HARLAND DR . Application Description: VILLA RESIDENCE / HVAC & HOT WATER HEATER LA QUINTA, CA 92253 . Property Zoning: Application Valuation: $27,612.00 Applicant: Contractor: IE INC HARRISON ENTERPRISES INC DBA GENERAL AIR 31225 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)343-7488 LIc. No.: 686310 Detail: HVAC AND HOT WATER HEATER CHANGE OUT - 17 SEER/80AFUE SPLIT SYSTEM TANKLESS WATER HEATER, AND (=.2) DUCTS. [2016 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT -QTY AMOUNT AIR HANDLER PC 101-0000-42600 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600' 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $38.00 Total Paid for MECHAN CAL: $190.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 Total Paid for PLUMBING FEES: $20.27 DESCRIPTION ACCOUNT .CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENTiFEE: $5.00 Bin # city of La Quinta Building 81: Safety Division Permit,'t. 178-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet Project Address: /-44(.,S0 N _ }.A Owner's Name: JC) A. P. Number: 'Address: -y y bSO . Legal Description: / City, ST, Zip: G� �jt Gly Q 22 S 3 Contractor: e e r a � a, Tele h nc: U- z� SCU Address: 3`�7p eSve\t' •U Project Description: ,t 2 c� 'T }'O, Al L c0 � Cit ST, Zi —•-y-----•– P� TePhone: le -7 (c0- _7 3 8 ess State Lie. C) City Lie. #; Arch., Engr., Designer: Address: City, ST, Zip: Telephone: P o . nt• cY- Co strut ton Type: Occupancy: State ,. Lie. # Project tYPa (circle one): New Add'n Alter Repair. r Demo. Name of Contact Person: s��h� Sq- Ft.: # Stories: #Units: Telephone # of Contact Person: ,B F 735 -7g 7lo Estimated Value of Project: Z% (p 2 , CIE-3 APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Rcc'd TRACKING PFRMITFEES . Plan Sels Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Clieck Delmsit Truss Calcs. Called Contact person Plan Check J3al-ince Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical " Grading plan 2'' Review, ready for corrections/issueElectrical . Subcontactor List Called Contact Person Plumbing Grant Deed . Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN ROUSE:- 'rd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees STATE OF CALIFORNIA ALTERATIONS - FIVAC I CEC-CFIR-ALT-04-E (Revised 01/16) CALIFOR 41A ENERGY COMMISSION "OiW— CERTIFICATE OF COMPLIANCE CF1R-ALT-04-E Alterations - HVAC CZ 2, and 8-15 (Page 1 of 1) Site Address: ` 1IL4 (a SO � • � O.r1 Gr� 7br Enforcement Agency: G �-. a La. Q,i A- Date Prepared: 21 -1 1 Permitil: Equipment Type Equipment Efficiency New Ducting or Lineset: Required R -value Conditioned Floor Area (ft) Thermostat ❑ Packaged Evaporator Coil 8O� AFUE COP ❑ R-6 (CZ 1-10, 12&13) Ducts Ser -ed bytem sys Setback System Condensing Unit ;KR -8' 14 16J Ducts 2 ($ ftpresent, (If not already (Split System ❑ Compressor (7 SEER HSPF .8 Line must ❑ Mini Split ❑ Lineset be installed) 'Furnace ❑ TXV EER HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. ❑ 1. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CFIR-ALT-02-E Condenser Unit, Evaporator Coil, CF2R-MCH-01-E, MCH -20-H, MCH -(23 or 24)2-H, MCH -25-H2 Compressor, TXV, Lineset, CF3R-MCH-20-H, MCH -(23 or 24)-H2, MCH -25-H2 Air Handler/Furnace2 (Can include new ducting) Installer Requirement: Duct leakage (5 15%, or 510% to outside, or seal all accessible leaks), Air Flow >_ 300 CFM/too, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duo in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ....... ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts3 CFIR-ALT-02-E including Mini Split CF2R-MCH-01-E, MCH -20-H, MCH -22-H, MCH -(23 or 24)-H2, MCH -25-H2 CF3R-MCH-20-H, MCH -22-H, MCH -(23 or 24)-H2, MCH -25-H2 Mini Splits require CF1R-ALT-02-E, CF2R-MCH-01-E, and (CF2R-CF3R) MCH -25-H Installer Requirement: Duct leakage < 5%, Fan Efficacy (0.58W/CFM), Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CF1R-ALT-02-E replaced: Condenser Unit, Evaporator Coil, CF2R-MCH-01-E, MCH -20-H, MCH -(23 or 24)-H, MCH -25-H Compressor, TXV, Lineset, Furnace' CF3R-MCH-20-H, MCH -(23 or 24)-H, MCH -25-H Installer Requirement: Duct leakage < 5%, Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet I Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts3 I CF1R-ALT-02-E, CF2R-MCH-20-H, CF3R-MCH-20-H Installer Required to: Duct leakage (5 15% or, 510% to outside or, or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting requires R-8 insulation when more than 40 ft installed in CZs 11 & 14-16 and R-6 in CZs 1-10, 12 &313, and R-6 insulation when less than 40 ft installed. This includes in walls, between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MCH -(23 or 24), or Refrigerant Charge verification MCH -25 3 All New Ducts is when at least 75%of the duct system is new duct material, and up to 25%may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles,.boots, air handler, coil, plenums, duct material) ° R-2.8 (1" thick insulation) for linesets 1" and less. Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Fart 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consiste®t with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submited to the enforcement agency for approval with this building permit application. Res nsible Design e: 42.%�w�fL Il n�q sible Designer nature;— Dat Si ed: z 7 1 License: (5:R6 3l o Company : er o i Address: 3\\-7u 7;�e5envC--bn City/State/zip: 7 o(22?lo7 Phone: coo-3Li3--7`i8$ z0. ror assistance or questions regaraing the Energy standards, contact the Energy Hotline at: 1-800-772-3300 SYATE OF CALIFORNIA RESIDENTIAL ALTERATIONS CERTIFICATE OF COMPLIANCE Prescriptive Residential Alterations l Project Name:tAi4iOG-ip 114 Date Prepared: Z CF1R-ALT-01-E (Page 1 of 4) A. GENERAL INFORMATION 01 ,:-, 01 Project Name: 02 Date Prepared: % 2 1-7 03 Project Location: 44g6 N 04 Building Front Orientaiion (deg or cardinal): 05 ._CA City: ,. -.-A a 06 IVumber of All6ed Uwelling Units: V*f,,\ 07 tip Code: 92253 08 Fuel Type: (�, C'w> ' S09 Climate Zone: 10 To6l,Conditioned FloovArea (ft2):> 11 Building Type 12 Slab Area (ft2)�,i,1 13 Project Scope: Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional) ( P� ) ( P ) B. BUILDING INSULATION DETAILS (Section 150.2(b)1) 01 02 03 04 05 06 ,-. 07 081 , r� 09 10 11 p %� Propos d Minimum Required Method of Roof CRRC Product ID ` Deck-- rjfro osed �n ,� Required 4 Pitch r -,Continuous `- ;_!Appendix JA4 *insulation Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional) ( P� ) ( P ) Frame Frame Frame Depth Spacing Cavity�,`ti 4,Insulation Reference NOTES ter. r ti • Roof area covered by build ing'integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. Tag/ID Assembly Type Type (inches) (inches) R value. t, '- R -value f= a U;factor Table. Cell LI -Factor Comments C. ROOF REPLACEMENT (Prescriptive Alteration, Sect1orr,150.2(b)1H) 01 02 03 04 ,^, ► 05,\ % )fN 06 tli '07 •1 08 09 10 11 12 1 13 R -value':' Propos d Minimum Required Method of Roof CRRC Product ID ` Deck-- `Initial Solar Aged Solar Thermal SRI Aged Solar Thermal SRI Compliance p Pitch Exception p f,(��Number �•'�` ?�,ProductT e . YP *insulation Reflectance Reflectance Emittance (Optional) Reflectance Emittance (Optional) ( P� ) ( P ) NOTES ter. r ti • Roof area covered by build ing'integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. • Liquid field appliedf�coatin_gs must comply with,installation criteria from section 110.8(i)4. V Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014 STATE OF t ALIFORNIA RESIDENTIAL ALTERATIONS CEC-CFIR-ALT-01-E Revised 06/14 CERTIFICATE OF COMPLIANCE Prescriptive Residential Alterations (' Project Name: y(a5O N a4 o r�o,�,. a CF1R-ALT-01-E (Page 3 of 4) Date Prepared: Z n F. SPACE CONDITIONING(SC) SYSTEMS — HEATING/COOLING (Prescriptive section 150.2(b)) 01 02 03 Dwelling Unit Name Dwelling Unit CFA (Ft2) Comnn,t` G. WATER HEATING SYSTEMS (Section 150.2(b)1G) 01 02 03 04 05 06 07 08 09 \. Y10 121 ? H12 13 14 15 Water Heating System 3,r Alteration to the Space k of Water (ft2)) 'Name -Identification or Name I { System Water Water Water Heater Rated Rated Heating CHei g y Exterior Back -Up Solar Dwelling Heaters Storage iE. may,.., Unit DHW Identification or Heating Heater in Volume Fuel Input a ttanP t Efficiency j ]E�fficiiency Standby Insul. Savings Central DHW System System Name System Type Type system (gal) Type Type Value Typed Value Loss. (%) R -Value I Fraction Distribution Type I Distribution Type Now, X-\ D U 1 V. s� • 1 N A s . B y 14q � ufj { Nato KV k N A tV �a N & oar. WE- _ � v +-4 H. SPACE CONDITIONING SYSTEMS AND WATER HEATING SYSTEMS INUULTIFAMILY;DWEUING UNITS 01 02 t ' 03 04 05 06 Central WaYer,Heating Dwelling Unit Dwelling Unit: Dwelling Unit,Total CFA Systemlldentification or t'�=�°Water�Heating ly \t System 3,r Alteration to the Space Dwelling Unit Name (ft2)) 'Name -Identification or Name Conditioning System(s)? Comments Registration Number: CA Building Energy Efficiency Standards - 2013 Residential Compliance NN Registration Date/time: HERS Provider: June 2014 STATE OF't ALIFORMIA RESIDENTIAL ALTERATIONS CEC-CF1R-ALT-01-E Revised 06/14 CALIFORNIA ENERGY COMMISSION r CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E Prescriptive. Residential Alterations (Page 4 of 4) Project Name: y4(,s I•� ai-�o. i lir Date Prepared: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of'Compliance documentation is accurate and complete. k Documentation Author Name: Docigpentation Author Sianature: Company: �+ G -,t %ero.)i Sign cure Date: -24 -7 '�n%; 117 Address: � CEA/ HERS Certification Ideniificatlori°(if applicable): .V City_/State/Zip: V,ct, c-1r.d �o,1m5 CA �fZ Lilo Phone: ?(oQ--7'�8� RESPONSIBLE PERSON'S DECLARATION STATEMENT x t4. I certify the following under penalty of perjury, under the laws of the State of California:'' 1. The information this Certificate Compliance is true provided on of and correct. builcling�decgv�or�ystem 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsilifiky,'for the. design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, compone'rit� manufactured -de e -s for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the Ga(ifornia Code of'RegulalionS. 4. The building design features or system design features identified on this Certificate of Compliance are consistent Withttt,e information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to th ee nfof ement agerlq for approval with this building permit application. i.5. 1 will ensure that a registered copy of this Certificate of Compllab&c ,shall be made available with the building permits) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a re istere c VI i w 1. L' pp p g , y'of this CCertlflc� Compliance 'Is;r red to be included with the documentation the builder provides to the building #1 1 , �f owner at occupancy. Responsible Designer Name:" Re,p'on able Designer Signature: � e_ver� S� htitcrG(- k t4» w�;Pi cz Company: UU a te D�iS-net% 2 1 Co, ` Address: i� Vf.?I Y R License: 311 C� \1 e s er v` r 44 T (0$(0 3l p City/State/Zip: A;��n CK --Z, Phone: --i6o- 34?- -?Lf 0 So,,- -7(, $s For assistance or -<questions regarding the Energy Standards, contact the Energy Hotline at. 1-800-772-3300. Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance June 2014