BRER2017-0002Applicant:
R D WINKLE COMPANY
'P 0 BOX 476
THOUSAND PALMS, CA 92276
i
Taff
U 4 aI "^"'�'� VOICE (760) 777-7125
v FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT ION 760) 777-7153
BUILDING PERMIT
✓,�NIZ.?o,lie: 017caner: ,
,,f�AA__ KLINb71
805 1
LA QUINTA
, r
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C39, C46 License No.: 688062
Contractor:
OWN ER -BU IE ECLARATI0N
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
Contractor:
R D WINKLE COMPANY.
P 0 BOX 476
THOUSAND PALM!, CA 92276
(760)322-5144
Llc. No.: 688062
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of 1rie following declarations:
I have and will maintain a certificate if consent to.self-insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance zarrier and polity number are:
Carrier: STATE COMPENSATION INSURANCE FUh D Policy Number: 9150308
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so a:. to become subject to the workers'
compensation laws of California, and agree that if I should become subject to the
workers' compensation provisions of Section 37•)0 of the Labor Code, I shall forthwith
comply with those provisions.
Datp, -/`( !/�!/�/I Annlirnnt-_/L 1V. 1 A, ��I'1d�.11ri
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000:- IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOW! EDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner,and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of is! uance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and staL- that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representati-es of this city to enter upon the
above-mentioned property for inspection purpofes.
77 �
D�r. r'�!� ZW / Signature _(Applicant_otiAgent) :
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BRER2017-0002
Property Address:
80574 HERMITAGE
APN:
762210034
Application Description:
KLINK RESIDENCE / REROOF
Property Zoning:
Application Valuation:
$18,522.00
Applicant:
R D WINKLE COMPANY
'P 0 BOX 476
THOUSAND PALMS, CA 92276
i
Taff
U 4 aI "^"'�'� VOICE (760) 777-7125
v FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT ION 760) 777-7153
BUILDING PERMIT
✓,�NIZ.?o,lie: 017caner: ,
,,f�AA__ KLINb71
805 1
LA QUINTA
, r
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C39, C46 License No.: 688062
Contractor:
OWN ER -BU IE ECLARATI0N
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
Contractor:
R D WINKLE COMPANY.
P 0 BOX 476
THOUSAND PALM!, CA 92276
(760)322-5144
Llc. No.: 688062
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of 1rie following declarations:
I have and will maintain a certificate if consent to.self-insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance zarrier and polity number are:
Carrier: STATE COMPENSATION INSURANCE FUh D Policy Number: 9150308
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so a:. to become subject to the workers'
compensation laws of California, and agree that if I should become subject to the
workers' compensation provisions of Section 37•)0 of the Labor Code, I shall forthwith
comply with those provisions.
Datp, -/`( !/�!/�/I Annlirnnt-_/L 1V. 1 A, ��I'1d�.11ri
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000:- IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOW! EDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner,and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of is! uance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and staL- that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representati-es of this city to enter upon the
above-mentioned property for inspection purpofes.
77 �
D�r. r'�!� ZW / Signature _(Applicant_otiAgent) :
Date: 1/12/2017
Application Number:
BRER2017-0002
Owner:
Property Address:
80574 HERMITAGE
JUDITH KLINK
APN:
762210034
80574 HERMITAGE
Application Description:
KLINK RESIDENCE / REROOF
LA QUINTA, CA 92253 .
Property Zoning:
Application Valuation:
$18,522.00
Applicant:
Contractor:
R D WINKLE COMPANY
R D WINKLE COMPANY
P 0 BOX 476
P 0 BOX 476
'THOUSAND PALMS, CA 92276
THOUSAND PALM6, CA 92276
(760)322-5144
Llc. No.: 688062
Detail: REROOF OF THE PITCHED & LOW SLOPE ROOF. EXISTING TILES TO RECEIVE
60 MILTPO OVER 1" EPS. PER 2016 EAERGY AND CALIFORNIA BUILDING
CODE.
Total Paid for RE-RDOF: $167.20
A
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT
.QTY
AMOUNT
BSAS SB1473 FEE
101-.0000-20306
0 °
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATIONi BSA:
$1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RE -ROOF - EA ADDITIONAL 1,000 SF
101-0000-42404
0
$12.16
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RE -ROOF - FIRST 2,000 SF
101-0000-42404
0
$51.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RE -ROOF - FIRST 2,000 SF PC
101-0000-42600
0
$103.36
Total Paid for RE-RDOF: $167.20
A
Bin. #City
�f La Quo
Building 8r Safety Division
P.O. Box 1504,78-495 Calle Tampico
a to •Quanta, CA 92253 -:(760) 777-7012
Building Permit Application'and Tracking Sheet
Permit #
ProjectAddress: 80574 Hermitage
Owner'sNwne:. Bruce Klink
A. P. Number:
Address: - 80574 Hermitage
Legal Description:
Contractor. R.D. Winkle Co.
City, ST, Zip: La Quinta, CA. 92253
Telephone:
Project Description:
Address: P.O. Box 476
City, ST, Zip: Thousand Palms, CA. 9.2276
Re -Roofing of the Pitched & Low -Slope Roof .
Telephone: 760-322-5144: '
StateLic.#: 688062 City Lia #;
Existing Tiles to be Reused.
Low -Slope to Receive 60mil TPO over 1" EPS
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:
State Lic. #: a
Name of Contact Person: Ryan A. Winkle
Construction Type: Roofing Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
- Sq. Ft.: 2,101 # Stories: 1 # Units:
Telephone # of Contact Person: 7607272-0003
Estimated Value of Project: $18,522.00
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Recd
TRACKING
PERMiT FEES
Plan Sets
Pian Cheng submitted
Item Amount
Structural Cales.
Reviewed, ready for corrections
Plan Check Deposit. .
Tross Calcs.
Called Contact Person
Plan Check Balance.
Tide 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted.,.Mechanical
Grading plan
2'i Review, ready for correctionsfissue
Electrical
Subcoutactor Ila
Called Contact Person
Plumbing
Grant Deed
Plans picked up
ML
H.O.A. Approval
Plain resubmitted
Grading
N RousE:-
''" Review; ready for eorrectlonsAmc
Developer Impact Fee
Planning Approval
Called Contact Person
A I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total PermitFees
i-.
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 3 of 5
Project Name: Climate Zone # # of Stories
80574 Hermitage, La Quinta, CA. 92253
ROOFING PRODUCTS (COOL ROOFS) §151(1)12
Mien the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1, 000ft , whichever is
less, the new roofing area must meet the roofing product "Cool Roof" requirements of §152(b)IH4 152(b)IHii, or 152(b)IH&
Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof ' requirements. Note: If any
one of the alternatives or exception below is checked, the Aged Solar Reflectance and TTtermal Emittance requirements for roofing products in
§118(1) are not applicable. Do not fill table below.
O Cool Roofs Not Required in Climate Zones 1-12, 14, and 16 with a Low Sloped. Less or 2:12 pitch.
❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less
than 5lb/ft2.
Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12)
❑ Insulation with a thermal resistance of at least 0.85 hrft •°FBtu or at least a 3/4 inch air -space is added to the roof 3eck
over an attic; or
❑ Existing ducts in the attic are insulated and sealed according to §151(f)10; or
❑ In climate zones 10,12 and 13, with 1 if of free ventilation area of attic ventilation for every 150 if of attic floor area, and
where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or
❑ Building has at least R-30 ceiling insulation; or
❑ Building has radiant barrier in the attic meeting the requirements of § 151(f)2; or
❑ Building has no ducts in the attic; or
❑ In climate zones 10,11,13 and 14, R-3 or greater roof deck insulation above vented attic.
Exception to §152(b)1Hiii, Low -slope roof (pitch 15 2:12)
❑ Building has no ducts in the attic.
Other Exceptions
❑ Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria.
❑ Roof constructions that have thermal mass over the roof membrane with at least 25 lb/f2 is exempt from the bebw Cool Roof criteria.
Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise,
Check the applicable box below if Exem t from the Roofing Products "Cool Roof ' R uirein :
Roof Slope
Product Weight
Product
Aged
Solar
Thermal
CRRC Product ID Number
< 2:12 > 2:12
< 5lb/ft2 > 5lb/ft2
T 2
ReflectancO.4
Emittance
SRIS
0628-0002
®
❑
❑
❑
TPO
❑4
.70
.86
85
0942-0043
13®
13C3
Tile
❑4
.33
.90
36
❑
❑
❑
❑
❑4
❑
❑
❑
❑
❑4
❑
❑
❑
❑
❑4
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroats.org/products/search php
2. Indicate the type ofproduct is being used for the rooftop, i.e. single -ply roof, asphalt roof, metal roof, etc.
3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the some
. directory and use the equation (0.2+0.7(pi„ itid— 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
5. Calculate the SRI value by using the SRI- Worksheet at http://lvtivtiv.energy ca. govltitle241 and enter the resulting value in the SFI Column above and attach acopy of
the SRI- Worksheet to the CF -IR.
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
ommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)1. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
113 Cement -Based Roof Coating
113 Other
Registration Number:
2008 Residential Compliance Forms
Registration Date/time: HERS Provider:
August 2009
Prescriptive Certificate of Compliance: Residential CF -IR -ALT
Residential Alterations Page 5 of 5
Project Name: Climate Zone # # of Stories
80574 Hermitage, La Quinta, CA. 92253
HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this
checklist below. A completed and signed CF4R Fonn for all the measures specified shall be submitted to the building inspector before final
inspection.
Duct Sealing & Testing HERS verification is required for this measure.
❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts arr installed in unconditioned
space, the ducts are to be sealed per §152(b)1Dii and the newly installed ducts are to be insulated per §151(f)10.
❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos.
❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the
ducts are to be sealed per §152(b)1Di.
❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler,
outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat m- hanger) the ducts are to be
sealed per § 152(b)IE.
❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS
verification in accordance with procedures in the Reference Residential Appendix RA3.
❑ EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space.
❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos.
Refrigerant Charge - Split System HERS verification is required for this measure.
❑ YES ❑ NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air
handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat
exchanger) a refrigerant charge measurement shall be verified per §152(b)IF.
Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw
The ventilation requirements of § 150 o do not apply to existing residential homes.
Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required fo.- this measure.
❑ YES ❑ NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is
replaced, the airflow and fan watt draw shall be verified per §152 b 1Ci to meet the recLArements of 151 7B.
Documentation Author's Declaration Statement
• I certify that this Certificate of Compliance documentation is accurate and complete.
Name:
Signature:
Ryan A. Winkle
Company:
Date:
R.D. Winkle co.
1-11-2017
Address:
If ApplicaUe ❑ CEA or ❑ CEPE
P.O. Box 476
(Certification #):
City/State/Zip:
Phone:
Thousand Palm, CA. 92276
760-272-0003
Responsible Building Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on
this Certificate of Compliance.
• I certify that the energy features and performance specifications for the building design identified on this Cer6ificate of Compliance conform
to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations.
• The building design features identified on this Certificate of Compliance are consistent with the information provided to document this
building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building rmit application.
Name:
Signature:
Ryan A. Winkle
—1 1,/ 1"44
Company:Date:
R.D. Winkle co.
1-11-2017
Address:
License:
P.O. Box 476
688062
City/State/Zip:
Phone:
Thousand Palm, CA. 92276
760272-0003
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1 -800 -77? -3300.
Registration Number:
2008 Residential Compliance Forms
Registration Date/Time: HERS: ravider.
August 2009
1 SEARCH RESULTS
Selected filters
`
Manufacturer: Carlisle Construction Materials Incorporated
PRINT
EXPORT ALL PRODUCTS
CRRC PROD. ID MANUFACTURER: BRAND
SRI MORE
PRODUCT TYPE
COLOR SOLAR REFLECTANCE
THERMAL EMITTANCE
MODEL
INFO
initial 3 year
initial 3 year
initial 3 year
0628-0002 Carlisle Construction Materials
Membrane: Single
Bright White 0.79
0.70
0.90
0.86 199
Incorporated: Sure -Weld
Ply Thermoplastic
185
TPO White
and Thermoset
k
Roofing
1
COOL ROOF RATING COUNCIL
1610 Harrison Street
Tel (866) 465-2523 or
Fa)• (510) 482-4421
Oakland, CA 94612
(510) 485-7175
Email: info@coolroofs.org
1 SEARCH RESULTS
Selected filters
Manufacturer: Boral Roofing
Please note that the CRRC does not set a minimum definition for cool;the CRRC simply lists the measured radiative property values on our Directory. A
product's placement on the Directory does not mean that the product is cool' as defined by any particular code body or prog-am.
`CRRC Rapid Ratings: These are interim laboratory -aged values that simulate weathered values. These values will be replaced with the measured three-year
aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim
rating.
PRINT EXPORT ALL PRODUCTS
CRRC PROD: ID MANUFACTURER: BRAND
PRODUCr TYPE
COLOR SOLAR REFLECTANCE THERMAL EMITTANCE SRI
MORE
MODEL
INFO
InitlaL 3 year InINaL 3 year Initial
3 year
0942-0043 Boral Roofing: Boral-Concrete
Steep Slope:
Orange, Black, 0.32
0.33
} 0.89
0.90
34
`36
Goldenrod
Concrete/Clay Tile
Multicolor
and Slates
COOL ROOF RATING COUNCIL 449 15th Street, Suite 400 TEL (866) 465-2523. EMAIL: info@coolroofs.org
Oakland, CA 94612 FAX (510) 482-4421
Ceruficare 3146.01
ICC -ES Evaluation Report ESR -1463
(� L ICC-ES/UL
Dual Report
Reissued August 1, 2012
This report is subject to renewal October 1, 2014.
Click on the logo to access UL Certification
www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
DIVISION: 07 00 00—THERMAL AND MOISTURE
PROTECTION
Section: 07 53 23—Ethylene-Propylene-Diene-Monomer
Roofing
Section: 07 5419—Polyvinyl-Chloride Roofing
Section: 07 54 23—Thermoplastic-Polyolefin Roofing
REPORT HOLDER:
CARLISLE SYNTEC INCORPORATED
PO BOX 7000
CARLISLE, PENNSYLVANIA 17013
(717) 245-7000
www.carlisle-syntec.com
EVALUATION SUBJECT:
CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING
MEMBRANES
ADDITIONAL LISTEES:
VERSICO INCORPORATED
POST OFFICE BOX 1289
CARLISLE, PA 17013
MULE -HIDE PRODUCTS COMPANYJNC.
1195 PRINCE HALL DRIVE
BELOIT, WISCONSIN 53511
WEATHERBOND
P.O. BOX 251
PLAINFIELD, PENNSYLVANIA 17081
KELLY COMPANY/2001 INC.
325 THOMASTON AVENUE
WATERBURY, CONNECTICUT 06702
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2006 Intemational Building Code® (IBC)
■ 2006 International Residential Code® (IRC)
■ Other Codes (see Section 8.0)
Properties evaluated:
■ Weather resistance
■ Roof covering fire classification
■ Wind uplift resistance
■ Impact resistance
2.0 USES
Carlisle ethylene propylene diene monomer (EPDM),
polyvinyl chloride (PVC) and thermoplastic polyolefin
(TPO) single -ply roofing membranes are used as roof
coverings in adhered and ,mechanically fastened
membrane roofing systems.
3.0 DESCRIPTION
3.1 General:
The EPDM, PVC and TPO Membrane Roofing Systems
described in this report consist of single -ply roofing
membranes, insulation where usad, barrier board or slip
sheet where used, flashing, mechanical fasteners and
adhesives that are installed on a combustible or
noncombustible deck. See Table 1 for Carlisle product
trade names and corresponding product names for
Mule -Hide Products Company, Inc., WeatherBond, Versico
Incorporated and Kelly Company2001 Inc., the additional
listees.
3.2 EPDM Membranes:
3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced
EPDM membrane available irb 45-, 60- and 90 -mil
(1. 14, 1.52, and 2.29 mm) thicknesses.
3.2.2 Sure -Seal FR: Sure -Seal FR is a black,
nonreinforced EPDM membrans with fire retardants,
available in 45-, 60- and 90 -mil (i.14, 1.52, and 2.29 mm)
thicknesses.
3.2.3 Sure -White: Sure -White is a white, nonreinforced
EPDM membrane available in a 60- and 90 -mil (1.52 and
2.29 mm) thickness.
3.2.4 Sure -Tough: Sure -Tough is a black, reinforced
membrane consisting of a polyester reinforcement
encapsulated between two EPDM membrane plies. It is
available in 45 -to 75 -mil (1.14 to 1.90 mm) thicknesses.
3.2.5 Sure -Tough FR: Sure -Trough FR is a black,
reinforced membrane consising of a polyester
reinforcement encapsulated between two EPDM
membrane plies with fire retardants. It is available in 45 to
60 -mil (1.14 to 1.52 mm) thickness.
3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is
a 45-, 60- or 90 -mil (1. 14, 1.52 or 2.29 mm) non -reinforced
EPDM bonded to a 5.5-ouncB-per-square-yard (0.18
kg/m2) polyester fleece.
3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK
is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white
EPDM bonded to a 5.5 -ounce -per- square -yard (0.18
kg /M2) polyester fleece.
ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they tote construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by7CC Evaluation Service, LLC. express or implied as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright O 2012
ortmmr �
Page 1 of 10
ESR -1463 I Most Widely Accepted and Trusted Page 2 of 10
3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or
90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM
bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2)
polyester fleece.
3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a
60 -mil (1.52 mm) non -reinforced EPDM bonded to a
7.5 -ounce -per -square -yard (0.25 kg /M2)
polyester fleece.
3.3 PVC Membranes:
3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and
Sure -Flex Elvaloy are 50-, 60-, or 80 -mil (1.27, 1.52, or
2.03 mm) membranes consisting of a polyester
reinforcement encapsulated between two plies of PVC.
The membrane is available in white, gray or custom colors.
3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure -
Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60-, or
80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a
fiberglass reinforcement encapsulated between two plies
of PVC. The membrane is available in white, gray or
custom colors.
3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex
Elvaloy FRS FleeceBACK: Sure -Flex FRS FleeceBACK
and Sure -Flex Elvaloy FRS FleeceBACK are the Sure -Flex
FRS membrane and the Sure -Flex Elvaloy FRS
membrane, described in Section 3.3.2 with a laminated
5.5 -ounce -per -square -yard (0.18 kg/m) polyester fleece
backing.
3.4 TPO Membranes:
3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or
1.52 mm) membrane consisting of a polyester
reinforcement encapsulated between two plies of TPO.
The membrane is available in white, gray, tan or custom
colors.
3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld
membrane formulated with an additional flame retardant
for fire resistance at higher slopes. It is manufactured in
45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is
available in white, gray, tan or custom colors.
3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of
Sure -Weld HS membrane with adhesive.
3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same
formulation as the Sure -Weld membrane but comes in
72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is
the same formulation as the Sure -Weld HS membrane but
comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses.
3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK
is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or
1.52 mm) thick with a laminated 5.5 -ounce -per -square -
yard (0.18 kg/m) polyester fleece backing.
3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil
(1.14 mm) Sure -Weld HS membrane with a laminated
10 -ounce -per -square -yard (0.34 kg /M2) polyester fleece
backing.
3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is
the 60 -mil (1.52 mm) Sure -Weld HS membrane with a
laminated 10 -ounce -per -square -yard (0.34 kg/m2)
polyester fleece backing.
3.4.9 Spectro-Weld: Spectro-Weld is the Sure -Weld
membrane, described in Section 3.4.1, and Sure -Weld
EXTRA membrane, described in Section 3.4.4, formulated
with a brighter white color. It is manufactured in 45-, 60-,
72- or 80 -mil (1.14-, 1.52-, 1.83- or 2.03 -mm) thicknesses.
3.4.10 Spectro-Weld FleeceBACK: Spectro-Weld
FleeceBACK is the Spectro-Weld membrane with a
laminated 5.5 -ounce -per -square -yard (0.18 kg/m2)
polyester fleece backing.
3.5 Insulation:
See Tables 2 through 4 for insulations for use with specific
roofing systems. Foam plastic insulation, where used, must
have a flame -spread index of not more than 75 when
tested at the maximum thickness intended for use in
accordance with ASTM E 84.
3.6 Barrier Board:
Barrier board, where used, must be either minimum
'/4 -inch -thick (6.4 mm) G -P Gypsum Corporation
"DensDeck," minimum '/4 -inch -thick (6.4 mm) Owens
Coming "Strataguard", minimum '/4 -inch -thick (6.4 mm)
USG "Securock," or minimum '/cinch -thick (12.7 mm)
gypsum board. Barrier board must be UL- listed for roofing
applications or UL -classified gypsum board.
3.7 Slip Sheet:
The slip sheet, where used, must include Carlisle "FR
Base Sheet 1S or 2S," Elk "VersaShield Underlayment,"
Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or
FR 50."
3.8 Flashing:
Flashing must be provided in accordance with IBC Section
1503.2 or IRC Section R903.2, as applicable. Where
flashing is of metal, the metal must be corrosion -resistant,
minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized
steel.
3.9 Fasteners:
Fasteners, used to mechanically attach insulation and
membranes to the roof deck, must be corrosion -resistant,
and must be Carlisle fasteners, plates or fastening bars,
unless otherwise noted in this report. Refer to Table 4 for
spacing of fasteners.
3.9.1 Sure -Seal HP Fastener: This is an epoxy -coated
steel screw used in combination with Carlisle's fastening
plates or bars to mechanically attach roofing insulation and
membranes to steel or wood substrate. Fastener length
must be selected to penetrate through the steel deck a
minimum of 3/4 inch (19.1 mm), and into the wood deck a
minimum of 1 inch (25.4 mm).
3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy -
coated steel screw used in combination with Carlisle's
fastening plates or bars to mechanically attach roofing
insulation and membranes to structural steel members.
Fastener length must be selected to penetrate through the
steel member a minimum of 3/4 inch (19.1 mm.)
3.9.3 Sure -Seal HD 14-10 Fastener: This is a heavy-
duty, epoxy -coated steel screw used in combination with
Carlisle's fastening plates or bars to mechanically attach
roofing insulation and membranes to concrete roof deck.
Fastener length must be selected to penetrate into the
concrete deck a minimum of 1 inch (25.4 mm).
3.9.4 Sure -Seal HP Polymer Seam Plate: This is a
2 -inch -diameter (50 mm) polymer plate designed to be
used with Sure -Seal HP and Sure -Seal HD 14-10
fasteners to mechanically attach roofing membranes to the
roof deck.
3.9.5 Sure -Tito Fastener and ST Fastening Bar: This is
a heavy-duty, epoxy -coated steel screw and bar used to
secure reinforced EPDM membranes to steel or wood
deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by -10 -
foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume-coated
steel with prepunched holes 6 inches (150 mm) on center.
ESR -1463 1 Most Widely Accepted and Trusted Page 3 of 10
3.9.6 HP -X Fastener: This is an epoxy -coated carbon
steel screw used in combination with the Piranha
Fastening Plate to mechanically attach TPO membranes to
steel or wood substrate. Fastener length must be selected
to penetrate through the steel deck a minimum of 3/4 inch
(19.1 mm), and into the wood deck a minimum of 1 inch
(25.4 mm).
3.9.7 Piranha Fastening Plate: This is a 23/8 -inch -
diameter galvalume-coated steel plate designed to be used
with HP -X fasteners to mechanically attach PVC and TPO
membranes to the roof deck.
3.9.8 HP-XTRA Fastener: This is an epoxy -coated
carbon steel screw used in combination with the Piranha
XTRA Fastening Plate to mechanically attach PVC and
TPO membranes to steel or wood substrate. Fastener
length must be selected to penetrate through the steel
deck a minimum of 3/4 inch (19.1 mm) and into the wood
deck a minimum of 1 inch (25.4 mm).
3.9.9 Piranha XTRA Fastening Plate: This is a
23/8 -inch -diameter galvalume-coated steel plate designed
to be used with HP-XTRA fasteners to mechanically attach
PVC and TPO membranes to the roof deck.
3.9.10 OMG Inc. RhinoBond Plate: The RhinoBond Plate
is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm)
galvalume-coated steel plate, coated with a proprietary
adhesive and used with the HP -X fastener to mechanically
attach PVC and TPO membranes to the roof deck. The
adhesive bonds the plate to the underside of the
membrane.
3.10 Adhesives:
3.10.1 Sure -Seal 90-8-30A: Sure -Seal 90-8-30A is a high-
strength, solvent -based contact adhesive used to adhere
EPDM membranes to the insulation or substrate. It has a
coverage rate of approximately 60 square feet per gallon
(1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L)
containers and has a shelf life of one year.
3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base
120 is a high-strength, water-based contact adhesive used
to adhere EPDM and TPO membranes to the insulation or
substrate. It has a coverage rate of approximately 120
square feet per gallon (3 M2 /L). The adhesive is supplied in
5 -gallon (18.9 L) containers and has a shelf life of
one year.
3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex
PVC and Sure -Flex Low VOC PVC Bonding Adhesives are
high-strength, solvent -based contact adhesives used to
adhere PVC membranes to an insulation or substrate.
They have a coverage rate of approximately 60 square feet
per gallon (1.5 m /L). The adhesives are supplied in
5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld
Bonding Adhesive is a high-strength, solvent -based
contact adhesive used to adhere TPO membranes to an
insulation or substrate. It has a coverage rate of
approximately 60 square feet per gallon (1.5 M2 /L). The
adhesive is supplied in 5 -gallon (18.9 L) containers with a
shelf life of one year.
3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding
Adhesive is a high-strength, solvent -based contact
adhesive used to adhere membranes to an insulation or
substrate. It has a coverage rate of approximately 60
square feet per gallon (1.5 m / L). The adhesive is supplied
in 5 -gallon (18.9 L) containers with a shelf life of one year.
3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST
Adhesive Dual Cartridge, FAST Adhesive Box Sets,
Flexible FAST and FAST Bag -in -a -Box Adhesives are
two -component polyurethane adhesives used to adhere
FleeceBACK membranes and insulations to various
substrates. The adhesives have a coverage rate of
approximately 100 square feet per gallon (2.5 M2 /L). The
adhesives are supplied in 15-gall,m (56.7 L) and 50 -gallon
(189 L) drums, cartridge tubes or cylinders, and have a
shelf life of one year.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements: for impact resistance in
IBC Section 1504.7, based on testing in accordance with
FM 4470.
4.0 INSTALLATION
4.1 General:
Installation of the EPDM, PVC, and TPO roofing
membranes described in this report must comply with the
applicable code, the manufacturer's published installation
instructions and this report. The -nanufacturer's published
installation instructions must be available at all times on
the jobsite during installation.
The substrate to which the membrane is to be applied
must be dean, dry, and free of frost, loose fasteners, and
other protrusions or contaminates that will interfere with the
adhesion or attachment of the membrane or that will
puncture the membrane. All mat3rials must be protected
against contact with incompa3ible materials. Where
gypsum board is used as barrier board in the roofing
assembly, weather protection must be provided to prevent
damage to the gypsum board prior to application of the
roofing membrane.
The slope of the roof on which tie single -ply membranes
are installed must not be more than the maximum slope
indicated for the particular assembly as listed in Tables
2 and 3.
Penetrations and terminations c1 the roof covering must
be flashed and made weather tight in accordance with the
requirements of the membrane! manufacturer and the
applicable code.
4.2 Fire Classification:
4.2.1 New Construction: The adhered and mechanically
fastened EPDM, PVC, and TPO single -ply membrane
roofing systems, when installed in accordance with this
report, are Class A, B or C roof covering systems in
accordance with ASTM E 108 and UL 790, as noted in
Tables 2 and 3.
4.2.2 Reroofing: The existing deck must be inspected to
verify that the structure to be reroofed is structurally sound
and adequate to support ant secure the roofing
membrane. Prior to installation of new roof coverings,
inspection by and written approval from the code official
having jurisdiction must be required.
Class A, B or C roof covering systems may be installed
over existing classified roof covering systems under the
following conditions without additional roof classification
tests, provided the resulting classification is the lower of
the new or existing roofing classification:
■ New uninsulated systems installed only over existing
uninsulated assemblies.
■ New insulated systems installed over existing
uninsulated systems only.
4.3 Wind Resistance:
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PV--, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
ESR -1463 I Most I/Ifidely Accepted and Trusted Page 4 of 10
Metal edge securement for roofing systems must be
designed in accordance with ANSI/SPRI ES -1, complying
with IBC Section 1504.5. The edge securement for
mechanically attached membranes was tested in
accordance with ANSI/SPRI ES -1 Test REA, using
Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003
aluminum] and Carlisle SecurEdge 3000 [0.040 -inch
(1.02 mm) 3003 aluminum] fascia systems. The maximum
allowable load for Carlisle SecurEdge 300 is 234 plf
(348 kg/m). The maximum, allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m).
4.3.2 Reroofing: Mechanically anchored systems may
be accepted based on the adequacy of anchors
penetrating through existing roof coverings into structural
substrates. Since the composition and/or condition of any
particular existing underlying material may vary widely,
reroofing with adhered systems is outside the scope of this
report.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 1.0 of this report, subject to the following
conditions:
5.1 Installation must comply with the applicable code, the
manufacturer's published installation instructions and
this report. The instructions within this report must
govern if there are any conflicts between the
manufacturer's installation instructions and this report.
5.2 The adhered and mechanically fastened single -ply
membrane roofing systems must be installed by
professional roofing contractors who are trained and
approved by the manufacturer.
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with IBC Section 2603.4.1.5 or IRC
Section R314.4, as applicable.
5.4 Foam plastic insulation, where used, must bear the
label of an approved agency indicating that the foam
plastic has a flame -spread index of not more than 75
when tested at the maximum thickness intended for
use in accordance with ASTM E 84, subject to the
approval of the code official.
5.5 Design wind uplift pressure on any roof area,
including edge and corner zones, must not exceed
the allowable wind uplift pressure for the system
installed in that particular area. Refer to allowable
wind uplift pressures for systems as listed in Table 4.
5.6 The allowable wind uplift pressures listed in Table 4
are for the roof covering system only. The deck and
framing to which the system is attached must be
designed for the applicable components and cladding
wind loads in accordance with the applicable code.
5.7 When application is over existing roofs,
documentation of the wind -uplift resistance of the
composite roof construction must be submitted to the
code official for approval at the time of permit
application.
5.8 The roofing membranes are manufactured at Carlisle,
Pennsylvania; Greenville, Illinois; Tooele, Utah; and
Senatobia, Mississippi, under a quality control
program with inspections by UL LLC (AA -668).
5.9 For buildings under the IBC, above -deck thermal
insulation board must comply with the applicable
standards listed in Table 1508.2 of the IBC.
6.0 EVIDENCE SUBMITTED
Data. in accordance with ICC -ES Acceptance Criteria for
Membrane Roof Covering Systems (AC75), dated April
2007, (corrected December 2008).
7.0 IDENTIFICATION
Each roll of the roofing membrane must bear a label noting
the product name, the manufacturer's name (Carlisle
SynTec Incorporated) or the name of the additional listee,
the manufacturer's address or plant code, the ICC -ES
evaluation report number (ESR -1463), and the name or
label of the inspection agency (UL LLC).
8.0 OTHER CODES
In addition to the codes referenced in Section 1.0, the
products in this report were evaluated for compliance with
the requirements of the. following codes:
■ BOCe National Building Code/1999 (BNBC)
■ 1999 Standard Building Code® (SBC)
■ 1997 Uniform Building Code'rm (UBC)
For compliance under the above codes, see Sections 2
through 7 of this report, except revise the following
sections to read as follows:
3.8 Flashing:
Flashing must be provided in accordance with SBC
Section 1503.2, BNBC Section 1508.1 and UBC Section
1509, as applicable. Where flashing is of metal, the metal
must be corrosion -resistant, minimum No. 26 gage [0.019
inch (0.483 mm)] galvanized steel.
3.11 Impact Resistance:
The EPDM, PVC, and TPO roofing membranes described
in this report meet requirements for impact resistance in
BNBC Section 1505.4.2, and SBC Section 1504.6, based
on testing in accordance with FM 4470.
4.3.1 New Construction: The allowable wind uplift
pressures for the EPDM, PVC, and TPO roofing
membranes as parts of roof assemblies are noted in
Tables 4 and 5.
5.0 CONDITIONS OF USE
The single -ply EPDM, PVC, and TPO roofing membranes
described in this report comply with, or are suitable
alternatives to what is specified in, those codes listed in
Section 8.0 of this report, subject to the following
conditions:
See Sections 5.1 through 5.8, except revise Section 5.3 to
read as follows:
5.3 Foam plastic insulation must be separated from the
interior of the building by an approved thermal barrier
in accordance with BNBC Section 2603.4.1.5, SBC
Section 2603.5.1.5, and UBC Sections 2602.4 and
2602.5.3, as applicable.
ESR -1463 1 Most Widely Accepted and Trusted Page 5 of 10
0'fioli:l
00tion 2
A
Ix
w*14M
_vd-
ali a�
FIGURE 1—INSPECTION AGENCY LABEL
ESR -1463 I Most Widely Accepted and Trusted Page 6 of 10
TABLE 1—PRODUCT NAMES
CARLISLE PRODUCT
MULE -HIDE PRODUCT
WEATHERBOND PRODUCT
VERSICO PRODUC—
KELLY COJ
NAME
NAME
NAME
NAME
2001 INC.
PRODUCT NAME
Sure -Seal
Mule -Hide Standard
WeatherBond RBR EPDM
Versigard
EPDM
Membrane
Sure -Seat FR
Mule -Hide FR EPDM
WeatherBond RBR FR EPDM
Versigard Nonreinforced
C-EPDM-C
Membrane
EPDM
Sure -Tough Reinforced
Mule -Hide Standard
WeatherBond RBR Standard
Versigard Reinforcec
C-EPDM-CR
Reinforced EPDM
Reinforced EPDM Membrane
Sure -Tough FR
Mule -Hide FR Reinforced
VersigardFR Reinforced
C-EPDM-CR Type 1
Reinforced
EPDM
Sure -White
Mule -Hide White -on-
WeatherBond RBR White, EPDM
Versigard Nonreinforced
EPDM RF- White
Black EPDM
Membrane
EPDM -White
Sure -Weld
Mule -Hide TPO-c
WeatherBond PRO TPO
Versiweld
Reinforced TPO / White
Membrane
TPO
Sure -Weld HS
Mule -Hide TPO-c (FR)
-
Versiweld ES
SAT-TPO
Mule -Hide SA-TPO
WeatherBond PRO PAS TPO
Versiweld QA TPO
Sure -Weld EXTRA
Mule -Hide TPO-c Extra
WeatherBond PRO TPO
Versiweld PLUS
Membrane
Sure -Weld HS EXTRA
Mule -Hide TPO-c Extra
Versiweld ES PLUS
(FR)
-
Sure -Weld FleeceBACK
Mute -Hide TPO-c Fleece
Versiweld VersiFleece
Back
Sure -Flex
Mule -Hide PVC
WeatherBond PRO PVC
VersiFlex Reinforced
Membrane
PVC Membrane
Sure -Flex FRS
Mule -Hide FRS PVC
VersiFlex FRS
Membrane
-
Reinforced PVC
Membrane
Sure -Seal 90-8-30A
Mule -Hide Bonding
WeatherBond RBR LC -60 Bonding
G200SA Yellow
2001 Inc. Bonding
Bonding Adhesive
Adhesive
Adhesive
Substrate Adhesive
Adhesive
Sure -Seal Aqua Base 120
Mute -Hide Water -Based
Aqua Base 120 Bonding Adhesive
Aqua Base 120 Bondirg
Bonding Adhesive
Bonding Adhesive
Adhesive
Sure -Weld Bonding
Mule -Hide TPO-c
WeatherBond PRO TPO Bonding
Versiweld Bonding
Adhesive
Bonding Adhesive
Adhesive
Adhesive
Sure -Weld Low VOC
Mule -Hide TPO-c Low
Versiweld LOW VOC
Bonding Adhesive _
VOC Bonding Adhesive
Bonding Adhesive
Sure -Flex PVC Bonding
Mule -Hide PVC Bonding
WeatherBond PRO PVC Bonding
VersiFlex PVC Bonding
Adhesive
Adhesive
Adhesive
Adhesive
Sure -Flex Low VOC PVC
Mule -Hide Low VOC
VersiFlex Low VOC PVC
Bonding Adhesive
PVC Bonding Adhesive
Bonding Adhesive
FAST 100 Adhesive
Mule -Hide SP -100
FAST 100 Adhesive
Adhesive
FAST 100 LV Adhesive -
Mule -Hide SP -100 -LT
FAST 100 LV Adhesive
Adhesive
ESR -1463 1 Most Widely Accepted and Trusted Page 7 of 10
TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEM_d2'5
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
MEMBRANE/MAX. ROOF SLOPE
NO.
CLASS
OR SLIP SHEET
Any of the following insulations,
Sure -Weld, Spectro-Weld -'/4:12
1 -inch min. to 6 -inch max.
Sure -Seal, Sure7ough, Sure -White, Sure -
thickness: Carlisle "SecurShield
Seal FleeceBACK Sure -Weld HS, SAT-TPO,
1
A
Noncombustible
-Polyiso",
"Polyiso HP -H", Hunter
Sure -Weld Fle?c eBACK1'Spectro-Weld
Panels "H -Shield" or
FleeceBACK - /2:12
"H -Shield -CG"
Sure -White FleeceBACK, Sure -Flex, Sure -
s
Flee FRS - /4:12
1/2 -inch -thick fiberboard°,'/2
inch -thick fiberboard or barrier
a
Sure -White FleeceBACK /4:12
board (see Section 3.6) over 5-
Sure -Seal, Sure -Tough - 1:12
2
A
Noncombustible
—
inch max Insulfoam EPS3,'/2-
Sure -White, Sure -Seal FleeceBACK, Sure -
inch -thick fiberboard or barrier
Weld, Spectro-VIfeld, Sure -Weld HS, SAT -
board (see Section 3.6) over
TPO, Sure -Weld FleeceBACK, Spectro-Weld
System No. 1 insulations
FleeceBACK, SureI Flex, Sure -Flex FRS -
1 /2:12
Sure -White FleeceBACK-3/4:12
Noncombustible or
Sure -White, Sure -Seal FleeceBACK - 11/2:12
Combustible - min.
Sure -Tough, Sure�Weld, Spectro-Weld, Sure -
3
A
15/32 -inch -thick
Barrier board
—
Weld FleeceBACK, Spectro-Weld
plywood or min.
(see Section 3.6)
FleeceBACK - 3:12
7/16inch-thick OSB.
Sure -Weld -iS, SAT-TPO - 4:12
Sure -Seal FR, Sure -Flex, Sure -Flex FRS -
unlmited slope
Any of the following insulations,
Sure-Weld_3pectro-Weld -'/4:12
Combustible - min.
Barrier board
1 -inch min.
Sure -Seal, Sure -Tough, Sure -White, Sure -
t5/32 -inch -thick
(see Section 3.6) or
to 6 -inch max. thickness:
"SecurShield
Seal FleeceBACK Sure -Weld HS, SAT-TPO,
4
A
plywood or min.
ply
Slip sheet: 2 layers
' Carlisle Polyiso",
Polyiso HP
Sure -Weld FleeceBACK, Spectro-Weld
Flee(----BACK/2:12
7 ch thick OSB.
(see Section 3.7)
-H",
Hunter Panels "H -Shield" or
Sure -White FleeceBACK, Sure -Flex, Sure -
"H -Shield -CG"
Flee FRS -3/4:12
Combustible - min.
,s
Any of the following insulations,
Sure -Weld, Spectro-Weld,Sure-Weld HS,
5
C
/32 -inch -thick
_
2 -inch min. to 6 -inch max.
SAT TPO, Sure -Flex, Sure Flex FRS -
plywood or min.
7/1 plywood
thickness: Carlisle "Polyiso HP-
unlimited slope
OSB.
H" or Hunter Panels "H -Shield"
Single layer of minimum 3.0" or'
double layer of minimum 1.5"
6
A
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, anc TPO Membranes -'/2:12
Hunter Panels
"H -Shield -CG"
Single layer of minimum 1.9"
7
B
Combustible
—
Carlisle "SecurShield Polyiso" or
EPDM, PVC, anc TPO Membranes -'/2:12
Hunter Panels
"H -Shield -CG"
For SI: 1 inch = 25.4 mm.
' All foam plastic insulation must be UL-classfied foamed plastic for roofing systems, and must be limited to the makimum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is lesa.
'See Section 3.10 for adhesive application rate.
3 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slopel :12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. 1/2:12.
5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
I
ESR -1463 I Most Widely Accepted and Trusted Page 8 of 10
TABLE 3—FIRE CLASSIFICATION ASSEM BUES— MECHANICALLY FASTENED ROOFING SYSTEMS"
SYSTEM
ROOF
DECK
BARRIER BOARD
INSULATION'
U=MBRANE/MAX. ROOF
NO.
CLASS
OR SUP SHEET
SLOPE
Any of the following insulations, 1 -inch min. to
Sure -Tough, Sure -Weld,
1
A
—
6 -inch max. thickness: Carlisle "SecurShield
Spedro-Weld, Sure -Flex, Sure -
Noncombustible
Polyiso" or "Polyiso HP -H", Hunter Panels "H-
"H
Flex FRS - /2:12
-Sure-Weld HS - 11/212
Shield" or -Shield -CG"
Sure -Tough FR - 2:12
1/2 -inch -thick fiberboard 3. 1/2 -inch -thick
Sure -Tough, Sure -Weld HS,
fiberboard or barrier board (see Section 3.6)
Sure: Flex, Sure -Flex FRS - 1:12
2
A
Noncombustible
—
over 5 -inch max Insulfoam EPS2,'/2-inch-thick
Sure -Weld, Spectro-Weld -
fiberboard or barrier board (see Section 3.6)
1'/2:12
over System No. 1 insulations
Sure -Tough FR - 31/2:12
Sure= -Weld, Spectro-Weld, Sure -
3
A
Noncombustible
—
To 5 -inch max: Insulfoam SP
Weld HS, Sure -Flex, Sure -Flex
FRS -'/2:12
Noncombustible or
Eure-Tough, Sure -Weld,
Combustible - min.
bo
Spectro-Weld - 3:12
4
A
15/3, inch -thick
(see der 3a6)
—
Sure -Tough FR - 3'/2:12
plywood or min.
Sure -Weld HS, Sure -Flex, Sure -
'/,6 -inch -thick OSB.
Flex FRS - unlimited
Combustible - min.
Barrier board
Any of the following insulations, 1 -inch min.
Eure-Tough, Sure -Weld,
15/szinch-thick
(see Section 3.6)
to 6 -inch max. thickness: Carlisle
Spedro-Weld, Sure -Flex, Sure -
5
A
plywood or min
or Slip sheet: 2
"SecurShield Polyiso" or "Polyiso HP -H",
,
Flex FRS - /2:12
/,inch thick OSB..
7/16-inch-thick
layers, see Section
y (3.7)
Hunter Panels
"H "H
Sure -Weld HS, 1'/2:12
-Shield" or -Shield -CG"
Sure -Tough FR - 2:12
Combustible - min.
Sure -Tough - 1:12
'5
/o
Slip sheet, 2 layers
Sure -Tough FR, Sure Weld,
6
A
d orr min.
plywood
(see Section 3.7)
—
Spedro-Weld, Sure -Weld HS,
7/1 �inch thick OSB.
Sire -Flex, Sure -Flex FRS -
1'/2:12
Combustible - min.
Sura -Tough, Sure -Tough FR,
7
B
15/32 -inch -thick
Slip sheet, 1 layer
—
Sere -Weld, Spectro-Weld,
plywood or min.
(see Section 3.7)
Sure -Weld HS, Sure -Flex, Sure -
'/,s -inch -thick OSB.
Flex FRS - 11/2:12
Combustible - min.
Any of the following insulations, 2 -inch min.
'5/3zinch-thick
to 6 -inch max. thickness: Carlisle
Sere -Weld, Spedro-Weld,
8
C
plywood or min.
—
"SecurShield Polyiso" or "Polyiso
"H
Sure -Weld HS, Sure -Flex, Sure-
ure-
7
7/is-inch-thick
/,5 inch thick OSB.
HP -H", Hunter Panels -Shield" or H -Shield
Flex FRS - unlimited
CG"
Single layer of minimum 3 -inch or double
9
A
Combustible
—
layer of minimum 1.5 -inch Carlisle
-'-:PDM, PVC, and TPO
"SecurShield Polyiso" or
Membranes -'/2:12
Hunter Panels "H -Shield -CG"
Single layer of minimum 1.9 -inch Carlisle
10
B
Combustible
—
"SecurShield Polyiso" or Hunter Panels "H-
[;-:PDM, PVC, and TPO
Shield -CG" or single layer of an inverted G3
Membranes -'/2:12
cap sheet.
For SI: 1 inch = 25.4 mm.
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less.
2 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboardl over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/2:12.
°When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.
ESR -1463 I Most Widely Accepted and Trusted Page 9 of 10
TABLE 4—WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°'' .
SYSTEM
MAXIMUM
DECKS
INSULATION 5
MEMBRANE
MEMBRANE
MAXIMUM
MAXIMUM
NO.
ALLOWABLE
FASTENING
FASTENER
FASTENER
WIND UPLIFT
SPACING
ROW
(psf)
(inches)
SPACINGS
Foam plastic
insulation'•z
1
45
Noncombustible
112-inch-thickSure
fiberboard or
Tough
HP -X Fastener &
Metal Fastening Bar
12
6 ft 6 inches
barrier board
(See Sect. 3.6)
2
75
Noncombustible
Same as System No. 1
Sure -Tough
HP -X Fastener &
Metal Fastening Bar
6
6 ft 6 inches
3
52
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
Polymer Seam Plate
6
9 ft 6 inches
4
45
Noncombustible
Same as System No. 1
Sure -Tough
Sure-Tde Fastener &
ST Fastening Bar
12
9 ft 6 inches
5
30
Noncombustible
Same as System No. 1
Sure -Tough
HP Fastener &
12
9 It 6 inches
(75 mil)
Polymer Seam Plate
6
60
Noncombustible
Same as System No. 1
Sure -Tough
(75 mil)
HP Fastener &
Polymer Seam Plate
6
9 ft 6 inches
Sure -Weld,
HP -X or HP -Xtra
7
45
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
7 ft 6 inches
Spectro-Weld
or Piranha Xtra Plates
8
45
Noncombustible
Same as System No. 1
Sure -Weld,
Sure -Weld EXTRA, or
HP -Xtra Fasteners with
12
9 ft 6 inches
Spectro-Weld
Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
9
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with
Piranha or Piranha Xtra
6
9 ft 6 inches
Spectro-Weld
Plates
Sure -Weld,
HP -X or HP -Xtra
10
67
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
7 It 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
11
30
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
12
11 It 6 inches
Spectro-Weld
or Piranha Xtra Plates
Sure -Weld,
HP -X or HP -Xtra
12
60
Noncombustible
Same as System No. 1
Sure -Weld EXTRA, or
Fasteners with Piranha
6
11 It 6 inches
Spectro-Weld
or Piranha Xtra Plates
13
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
Piranha Plates
6
6 ft 4 inches
14
83
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
Piranha Plates
6
2 ft 11 inches
HP -X or HP -Xtra
15
30
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
18
6 ft 4 inches
or Piranha Xtra Plates
HP -X or HP -Xtra
16
45
Noncombustible
Same as System No. 1
Sure -Flex
Fasteners with Piranha
12
6 ft 4 inches
or Piranha Xtra Plates
17
53
Noncombustible
Same as System No. 1
Sure -Flex
HP -X Fasteners with
Piranha Plates
12
2 ft 11 inches
18
45
Noncombustible
Same as System No. 1
Sure -Weld
HP -X Fasteners with
OMG RhinoBond Plates
1 per 5.3 ftz
N/A
19
60
Noncombustible
Same as System No. 1
Sure -Weld
Fasteners with
1 per 4 ftz
N/A
OMG RhinoBond Plates
For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa.
'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShielc Polyiso","Polyiso HP -H"
Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG".
2All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the n-aximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is lass.
'Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (f.) of 2500 psi. See Section 5.6 of this report.
°For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle
iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2.
5 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulatio-is (max slope1:12) or below
min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks.
6Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboErd over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12.
ESR -1463 I Most Widely Accepted and Trusted Page 10 of 10
' Table 4 footnotes cont'd
When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and
IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, ac applicable.
8 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof
assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle
SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must to determined accordingly.
TABLE 5—WIND RESISTANCE — ADHERED ASSEMBLIES5
SYSTEM
ALLOWABLE
DECK
INSULATION / MIN. THICKNESS'"3
INSULATION
MEMBRANE
NO.
WIND UPLIFT
FASTENING
TYPE
(FIELD) (psf)
RATE
1
45
Combustible or
1/2 Inch fiberboard °, 15/32 inch OSB, or barrier board (See
1 per 2 112
EPDM, PVC and TPO
Noncombustible
Section 3.6)
Membranes
2
45
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
Panels "H -Shield" "H -Shield -CG"/ 1.4 inch
1 3.2 ft2
EPDM, PVC and TPO
Noncombustible
or
with'/2-inch Securock ooverboard (optional)
per
Membranes
3
45
Combustible or
Carlisle "Polylso HP -H" or "SecurShield Potyiso"; Hunter
Panels "H -Shield" or "H -Shield -CG" / 2.0 inch
1 4 ft2
EPDM, PVC and TPO
Noncombustible
with 5/B -inch Securock ooverboard (optional)
per
Membranes
4
68
Combustible or
Carlisle "Potyiso HP -H" or "SecurShield Polytso"; Hunter
FAST Adhesive
FleeceBACK Membranes
Noncombustible
Panels "H -Shield" or "H -Shield -CG"/ 1.0 inch
5
75
Combustible or
Carlisle "Polyiso HP -H" or "SecurShleld Polylso"; Hunter
Panels "H -Shield" "H -Shield -CG"/ 2.0 inch
1 1.6 ft2
EPDM, PVC and TPO
Noncombustible
or
with'/2-inch Securock coverboard (optional)
per
Membranes
6
120
Combustible or
Carlisle "Polyiso HP -H" or "SecurShleld Polylso"; HunterTPO
"H "H
1 per 1 tt2
Membranes;
EPDM membranes (with
Noncombustible
Panels -Shield" or -Shield -CG" / 2.0 inch
noncombustible deck only)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShleld Polyiso"; Hunter
7
128
Noncombustible
Panels "H -Shield" or "H-Shleld-CG" / 2.0 inch
1 per 1 ft2
EPDM and TPO Membranes
with'/2-inch Securock ooverboard (optional)
Combustible or
Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter
8
135
Noncombustible
Panels "H -Shield" or "H -Shield -CG"/ 2.0 inch
1 per 1 ft2
FleeceBACK Membranes
with'/2-inch Securock ooverboard (optional)
9
143
Combustible or
Noncombustible
1/2 inch DensDeck Prime
1 per 1 ft2
FleeceBACK Membranes
For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa
'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in
accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is Ib -ss.
2Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum
compressive strength (f'.) of 2500 psi. See Section 5.6 of this report.
3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below
min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible dEcks.
°Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When
these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/2:12.
5When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to
the code official for approval at the time of permit application. For reroofing or recovering, installation must be irb accordance with IBC Section
1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable