Loading...
BRER2017-0002Applicant: R D WINKLE COMPANY 'P 0 BOX 476 THOUSAND PALMS, CA 92276 i Taff U 4 aI "^"'�'� VOICE (760) 777-7125 v FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT ION 760) 777-7153 BUILDING PERMIT ✓,�NIZ.?o,lie: 017caner: , ,,f�AA__ KLINb71 805 1 LA QUINTA , r LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C39, C46 License No.: 688062 Contractor: OWN ER -BU IE ECLARATI0N I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Contractor: R D WINKLE COMPANY. P 0 BOX 476 THOUSAND PALM!, CA 92276 (760)322-5144 Llc. No.: 688062 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of 1rie following declarations: I have and will maintain a certificate if consent to.self-insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance zarrier and polity number are: Carrier: STATE COMPENSATION INSURANCE FUh D Policy Number: 9150308 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a:. to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 37•)0 of the Labor Code, I shall forthwith comply with those provisions. Datp, -/`( !/�!/�/I Annlirnnt-_/L 1V. 1 A, ��I'1d�.11ri WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000:- IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOW! EDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner,and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of is! uance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and staL- that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representati-es of this city to enter upon the above-mentioned property for inspection purpofes. 77 � D�r. r'�!� ZW / Signature _(Applicant_otiAgent) : 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRER2017-0002 Property Address: 80574 HERMITAGE APN: 762210034 Application Description: KLINK RESIDENCE / REROOF Property Zoning: Application Valuation: $18,522.00 Applicant: R D WINKLE COMPANY 'P 0 BOX 476 THOUSAND PALMS, CA 92276 i Taff U 4 aI "^"'�'� VOICE (760) 777-7125 v FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT ION 760) 777-7153 BUILDING PERMIT ✓,�NIZ.?o,lie: 017caner: , ,,f�AA__ KLINb71 805 1 LA QUINTA , r LICENSED CONTRACTOR'S DECLARATION ' I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C39, C46 License No.: 688062 Contractor: OWN ER -BU IE ECLARATI0N I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Contractor: R D WINKLE COMPANY. P 0 BOX 476 THOUSAND PALM!, CA 92276 (760)322-5144 Llc. No.: 688062 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of 1rie following declarations: I have and will maintain a certificate if consent to.self-insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance zarrier and polity number are: Carrier: STATE COMPENSATION INSURANCE FUh D Policy Number: 9150308 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a:. to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 37•)0 of the Labor Code, I shall forthwith comply with those provisions. Datp, -/`( !/�!/�/I Annlirnnt-_/L 1V. 1 A, ��I'1d�.11ri WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000:- IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOW! EDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner,and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of is! uance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and staL- that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representati-es of this city to enter upon the above-mentioned property for inspection purpofes. 77 � D�r. r'�!� ZW / Signature _(Applicant_otiAgent) : Date: 1/12/2017 Application Number: BRER2017-0002 Owner: Property Address: 80574 HERMITAGE JUDITH KLINK APN: 762210034 80574 HERMITAGE Application Description: KLINK RESIDENCE / REROOF LA QUINTA, CA 92253 . Property Zoning: Application Valuation: $18,522.00 Applicant: Contractor: R D WINKLE COMPANY R D WINKLE COMPANY P 0 BOX 476 P 0 BOX 476 'THOUSAND PALMS, CA 92276 THOUSAND PALM6, CA 92276 (760)322-5144 Llc. No.: 688062 Detail: REROOF OF THE PITCHED & LOW SLOPE ROOF. EXISTING TILES TO RECEIVE 60 MILTPO OVER 1" EPS. PER 2016 EAERGY AND CALIFORNIA BUILDING CODE. Total Paid for RE-RDOF: $167.20 A DESCRIPTION FINANCIAL INFORMATION ACCOUNT .QTY AMOUNT BSAS SB1473 FEE 101-.0000-20306 0 ° $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATIONi BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RE -ROOF - EA ADDITIONAL 1,000 SF 101-0000-42404 0 $12.16 DESCRIPTION ACCOUNT QTY AMOUNT RE -ROOF - FIRST 2,000 SF 101-0000-42404 0 $51.68 DESCRIPTION ACCOUNT QTY AMOUNT RE -ROOF - FIRST 2,000 SF PC 101-0000-42600 0 $103.36 Total Paid for RE-RDOF: $167.20 A Bin. #City �f La Quo Building 8r Safety Division P.O. Box 1504,78-495 Calle Tampico a to •Quanta, CA 92253 -:(760) 777-7012 Building Permit Application'and Tracking Sheet Permit # ProjectAddress: 80574 Hermitage Owner'sNwne:. Bruce Klink A. P. Number: Address: - 80574 Hermitage Legal Description: Contractor. R.D. Winkle Co. City, ST, Zip: La Quinta, CA. 92253 Telephone: Project Description: Address: P.O. Box 476 City, ST, Zip: Thousand Palms, CA. 9.2276 Re -Roofing of the Pitched & Low -Slope Roof . Telephone: 760-322-5144: ' StateLic.#: 688062 City Lia #; Existing Tiles to be Reused. Low -Slope to Receive 60mil TPO over 1" EPS Arch., Engr., Designer. Address: City., ST, Zip: Telephone: State Lic. #: a Name of Contact Person: Ryan A. Winkle Construction Type: Roofing Occupancy: Project type (circle one): New Add'n Alter Repair Demo - Sq. Ft.: 2,101 # Stories: 1 # Units: Telephone # of Contact Person: 7607272-0003 Estimated Value of Project: $18,522.00 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMiT FEES Plan Sets Pian Cheng submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Tross Calcs. Called Contact Person Plan Check Balance. Tide 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted.,.Mechanical Grading plan 2'i Review, ready for correctionsfissue Electrical Subcoutactor Ila Called Contact Person Plumbing Grant Deed Plans picked up ML H.O.A. Approval Plain resubmitted Grading N RousE:- ''" Review; ready for eorrectlonsAmc Developer Impact Fee Planning Approval Called Contact Person A I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total PermitFees i-. Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 3 of 5 Project Name: Climate Zone # # of Stories 80574 Hermitage, La Quinta, CA. 92253 ROOFING PRODUCTS (COOL ROOFS) §151(1)12 Mien the area of exterior roof surface to be replaced exceeds more than 50% of the existing roof area, or more than 1, 000ft , whichever is less, the new roofing area must meet the roofing product "Cool Roof" requirements of §152(b)IH4 152(b)IHii, or 152(b)IH& Check applicable alternative or exception below if the roof alteration is exempt from the roofing product "Cool Roof ' requirements. Note: If any one of the alternatives or exception below is checked, the Aged Solar Reflectance and TTtermal Emittance requirements for roofing products in §118(1) are not applicable. Do not fill table below. O Cool Roofs Not Required in Climate Zones 1-12, 14, and 16 with a Low Sloped. Less or 2:12 pitch. ❑Cool Roofs Not Required in Climate Zones 1 through 9 and 16 with a Steep -Sloped Roofs (pitch greater than 2:12) and product unit weight less than 5lb/ft2. Alternatives to §152(b)1Hi and §152(b)Hii, Steep -slope roof (pitch > 2:12) ❑ Insulation with a thermal resistance of at least 0.85 hrft •°FBtu or at least a 3/4 inch air -space is added to the roof 3eck over an attic; or ❑ Existing ducts in the attic are insulated and sealed according to §151(f)10; or ❑ In climate zones 10,12 and 13, with 1 if of free ventilation area of attic ventilation for every 150 if of attic floor area, and where at least 30 percent of the free ventilation area is within 2 feet vertical distance of the roof ridge; or ❑ Building has at least R-30 ceiling insulation; or ❑ Building has radiant barrier in the attic meeting the requirements of § 151(f)2; or ❑ Building has no ducts in the attic; or ❑ In climate zones 10,11,13 and 14, R-3 or greater roof deck insulation above vented attic. Exception to §152(b)1Hiii, Low -slope roof (pitch 15 2:12) ❑ Building has no ducts in the attic. Other Exceptions ❑ Roofing area covered by building integrated; photovoltaic panels and solar thermal panels are exempt from the below Cool Roof criteria. ❑ Roof constructions that have thermal mass over the roof membrane with at least 25 lb/f2 is exempt from the bebw Cool Roof criteria. Note: If no CRRC-1 label is available, this compliance method cannot be used, use the Performance Approach to show compliance, otherwise, Check the applicable box below if Exem t from the Roofing Products "Cool Roof ' R uirein : Roof Slope Product Weight Product Aged Solar Thermal CRRC Product ID Number < 2:12 > 2:12 < 5lb/ft2 > 5lb/ft2 T 2 ReflectancO.4 Emittance SRIS 0628-0002 ® ❑ ❑ ❑ TPO ❑4 .70 .86 85 0942-0043 13® 13C3 Tile ❑4 .33 .90 36 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 ❑ ❑ ❑ ❑ ❑4 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at www.coolroats.org/products/search php 2. Indicate the type ofproduct is being used for the rooftop, i.e. single -ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the some . directory and use the equation (0.2+0.7(pi„ itid— 0.2) to obtain a calculated aged value. Where pis the Initial Solar Reflectance. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. Calculate the SRI value by using the SRI- Worksheet at http://lvtivtiv.energy ca. govltitle241 and enter the resulting value in the SFI Column above and attach acopy of the SRI- Worksheet to the CF -IR. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage ommended by the coatings manufacturer and meet minimum performance requirements listed in § 118(i)1. Select the applicable coating: ❑ Aluminum -Pigmented Asphalt Roof Coating 113 Cement -Based Roof Coating 113 Other Registration Number: 2008 Residential Compliance Forms Registration Date/time: HERS Provider: August 2009 Prescriptive Certificate of Compliance: Residential CF -IR -ALT Residential Alterations Page 5 of 5 Project Name: Climate Zone # # of Stories 80574 Hermitage, La Quinta, CA. 92253 HERS VERIFICATION SUMMARY The enforcement agency should pay special attention to the HERS Measures specified in this checklist below. A completed and signed CF4R Fonn for all the measures specified shall be submitted to the building inspector before final inspection. Duct Sealing & Testing HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if more than 40 linear feet of new or replacement ducts arr installed in unconditioned space, the ducts are to be sealed per §152(b)1Dii and the newly installed ducts are to be insulated per §151(f)10. ❑ EXCEPTION: Existing duct systems that are extended, which are constructed, insulated or sealed with asbestos. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing space -conditioning system (HVAC equipment and ducting) is replaced, the ducts are to be sealed per §152(b)1Di. ❑ YES ❑ NO YES: In Climate Zones 2 and 9-16, if the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system, cooling or heating coil, or the furnace heat m- hanger) the ducts are to be sealed per § 152(b)IE. ❑ EXCEPTION: Duct systems that are documented to have been previously sealed confirmed through HERS verification in accordance with procedures in the Reference Residential Appendix RA3. ❑ EXCEPTION: Duct systems with less than 40 linear feet in unconditioned space. ❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Refrigerant Charge - Split System HERS verification is required for this measure. ❑ YES ❑ NO YES: In Climate Zones 2 and 8-15, when the existing HVAC equipment is replaced (including the replacement of the air handler, outdoor condensing unit of a split system A/C or heat pump, cooling or heating coil, or the furnace heat exchanger) a refrigerant charge measurement shall be verified per §152(b)IF. Central Fan Integrated (CFI) Ventilation System and Fan Watt Draw The ventilation requirements of § 150 o do not apply to existing residential homes. Ducted Split Systems - Air Conditioners and Heat Pumps: Airflow HERS verification is required fo.- this measure. ❑ YES ❑ NO YES: In Climate Zones 10 through 15, when the existing space -conditioning system (HVAC equipment and ducting) is replaced, the airflow and fan watt draw shall be verified per §152 b 1Ci to meet the recLArements of 151 7B. Documentation Author's Declaration Statement • I certify that this Certificate of Compliance documentation is accurate and complete. Name: Signature: Ryan A. Winkle Company: Date: R.D. Winkle co. 1-11-2017 Address: If ApplicaUe ❑ CEA or ❑ CEPE P.O. Box 476 (Certification #): City/State/Zip: Phone: Thousand Palm, CA. 92276 760-272-0003 Responsible Building Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the building design identified on this Cer6ificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations. • The building design features identified on this Certificate of Compliance are consistent with the information provided to document this building design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building rmit application. Name: Signature: Ryan A. Winkle —1 1,/ 1"44 Company:Date: R.D. Winkle co. 1-11-2017 Address: License: P.O. Box 476 688062 City/State/Zip: Phone: Thousand Palm, CA. 92276 760272-0003 For assistance or questions regarding the Energy Standards, contact the Energy Hotline at. 1 -800 -77? -3300. Registration Number: 2008 Residential Compliance Forms Registration Date/Time: HERS: ravider. August 2009 1 SEARCH RESULTS Selected filters ` Manufacturer: Carlisle Construction Materials Incorporated PRINT EXPORT ALL PRODUCTS CRRC PROD. ID MANUFACTURER: BRAND SRI MORE PRODUCT TYPE COLOR SOLAR REFLECTANCE THERMAL EMITTANCE MODEL INFO initial 3 year initial 3 year initial 3 year 0628-0002 Carlisle Construction Materials Membrane: Single Bright White 0.79 0.70 0.90 0.86 199 Incorporated: Sure -Weld Ply Thermoplastic 185 TPO White and Thermoset k Roofing 1 COOL ROOF RATING COUNCIL 1610 Harrison Street Tel (866) 465-2523 or Fa)• (510) 482-4421 Oakland, CA 94612 (510) 485-7175 Email: info@coolroofs.org 1 SEARCH RESULTS Selected filters Manufacturer: Boral Roofing Please note that the CRRC does not set a minimum definition for cool;the CRRC simply lists the measured radiative property values on our Directory. A product's placement on the Directory does not mean that the product is cool' as defined by any particular code body or prog-am. `CRRC Rapid Ratings: These are interim laboratory -aged values that simulate weathered values. These values will be replaced with the measured three-year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating. PRINT EXPORT ALL PRODUCTS CRRC PROD: ID MANUFACTURER: BRAND PRODUCr TYPE COLOR SOLAR REFLECTANCE THERMAL EMITTANCE SRI MORE MODEL INFO InitlaL 3 year InINaL 3 year Initial 3 year 0942-0043 Boral Roofing: Boral-Concrete Steep Slope: Orange, Black, 0.32 0.33 } 0.89 0.90 34 `36 Goldenrod Concrete/Clay Tile Multicolor and Slates COOL ROOF RATING COUNCIL 449 15th Street, Suite 400 TEL (866) 465-2523. EMAIL: info@coolroofs.org Oakland, CA 94612 FAX (510) 482-4421 Ceruficare 3146.01 ICC -ES Evaluation Report ESR -1463 (� L ICC-ES/UL Dual Report Reissued August 1, 2012 This report is subject to renewal October 1, 2014. Click on the logo to access UL Certification www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 5419—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC INCORPORATED PO BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717) 245-7000 www.carlisle-syntec.com EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING MEMBRANES ADDITIONAL LISTEES: VERSICO INCORPORATED POST OFFICE BOX 1289 CARLISLE, PA 17013 MULE -HIDE PRODUCTS COMPANYJNC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 WEATHERBOND P.O. BOX 251 PLAINFIELD, PENNSYLVANIA 17081 KELLY COMPANY/2001 INC. 325 THOMASTON AVENUE WATERBURY, CONNECTICUT 06702 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2006 Intemational Building Code® (IBC) ■ 2006 International Residential Code® (IRC) ■ Other Codes (see Section 8.0) Properties evaluated: ■ Weather resistance ■ Roof covering fire classification ■ Wind uplift resistance ■ Impact resistance 2.0 USES Carlisle ethylene propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single -ply roofing membranes are used as roof coverings in adhered and ,mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single -ply roofing membranes, insulation where usad, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule -Hide Products Company, Inc., WeatherBond, Versico Incorporated and Kelly Company2001 Inc., the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced EPDM membrane available irb 45-, 60- and 90 -mil (1. 14, 1.52, and 2.29 mm) thicknesses. 3.2.2 Sure -Seal FR: Sure -Seal FR is a black, nonreinforced EPDM membrans with fire retardants, available in 45-, 60- and 90 -mil (i.14, 1.52, and 2.29 mm) thicknesses. 3.2.3 Sure -White: Sure -White is a white, nonreinforced EPDM membrane available in a 60- and 90 -mil (1.52 and 2.29 mm) thickness. 3.2.4 Sure -Tough: Sure -Tough is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies. It is available in 45 -to 75 -mil (1.14 to 1.90 mm) thicknesses. 3.2.5 Sure -Tough FR: Sure -Trough FR is a black, reinforced membrane consising of a polyester reinforcement encapsulated between two EPDM membrane plies with fire retardants. It is available in 45 to 60 -mil (1.14 to 1.52 mm) thickness. 3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is a 45-, 60- or 90 -mil (1. 14, 1.52 or 2.29 mm) non -reinforced EPDM bonded to a 5.5-ouncB-per-square-yard (0.18 kg/m2) polyester fleece. 3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white EPDM bonded to a 5.5 -ounce -per- square -yard (0.18 kg /M2) polyester fleece. ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they tote construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by7CC Evaluation Service, LLC. express or implied as to any finding or other matter in this report, or as to any product covered by the report. Copyright O 2012 ortmmr � Page 1 of 10 ESR -1463 I Most Widely Accepted and Trusted Page 2 of 10 3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non -reinforced EPDM bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece. 3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a 60 -mil (1.52 mm) non -reinforced EPDM bonded to a 7.5 -ounce -per -square -yard (0.25 kg /M2) polyester fleece. 3.3 PVC Membranes: 3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and Sure -Flex Elvaloy are 50-, 60-, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a polyester reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray or custom colors. 3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure - Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60-, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a fiberglass reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray or custom colors. 3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex Elvaloy FRS FleeceBACK: Sure -Flex FRS FleeceBACK and Sure -Flex Elvaloy FRS FleeceBACK are the Sure -Flex FRS membrane and the Sure -Flex Elvaloy FRS membrane, described in Section 3.3.2 with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m) polyester fleece backing. 3.4 TPO Membranes: 3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or 1.52 mm) membrane consisting of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available in white, gray, tan or custom colors. 3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. It is manufactured in 45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is available in white, gray, tan or custom colors. 3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of Sure -Weld HS membrane with adhesive. 3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same formulation as the Sure -Weld membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is the same formulation as the Sure -Weld HS membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or 1.52 mm) thick with a laminated 5.5 -ounce -per -square - yard (0.18 kg/m) polyester fleece backing. 3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil (1.14 mm) Sure -Weld HS membrane with a laminated 10 -ounce -per -square -yard (0.34 kg /M2) polyester fleece backing. 3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is the 60 -mil (1.52 mm) Sure -Weld HS membrane with a laminated 10 -ounce -per -square -yard (0.34 kg/m2) polyester fleece backing. 3.4.9 Spectro-Weld: Spectro-Weld is the Sure -Weld membrane, described in Section 3.4.1, and Sure -Weld EXTRA membrane, described in Section 3.4.4, formulated with a brighter white color. It is manufactured in 45-, 60-, 72- or 80 -mil (1.14-, 1.52-, 1.83- or 2.03 -mm) thicknesses. 3.4.10 Spectro-Weld FleeceBACK: Spectro-Weld FleeceBACK is the Spectro-Weld membrane with a laminated 5.5 -ounce -per -square -yard (0.18 kg/m2) polyester fleece backing. 3.5 Insulation: See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must have a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84. 3.6 Barrier Board: Barrier board, where used, must be either minimum '/4 -inch -thick (6.4 mm) G -P Gypsum Corporation "DensDeck," minimum '/4 -inch -thick (6.4 mm) Owens Coming "Strataguard", minimum '/4 -inch -thick (6.4 mm) USG "Securock," or minimum '/cinch -thick (12.7 mm) gypsum board. Barrier board must be UL- listed for roofing applications or UL -classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle "FR Base Sheet 1S or 2S," Elk "VersaShield Underlayment," Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or FR 50." 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.9 Fasteners: Fasteners, used to mechanically attach insulation and membranes to the roof deck, must be corrosion -resistant, and must be Carlisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 for spacing of fasteners. 3.9.1 Sure -Seal HP Fastener: This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy - coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/4 inch (19.1 mm.) 3.9.3 Sure -Seal HD 14-10 Fastener: This is a heavy- duty, epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.4 Sure -Seal HP Polymer Seam Plate: This is a 2 -inch -diameter (50 mm) polymer plate designed to be used with Sure -Seal HP and Sure -Seal HD 14-10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.5 Sure -Tito Fastener and ST Fastening Bar: This is a heavy-duty, epoxy -coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1 -inch -wide -by -0.040 -inch -thick -by -10 - foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume-coated steel with prepunched holes 6 inches (150 mm) on center. ESR -1463 1 Most Widely Accepted and Trusted Page 3 of 10 3.9.6 HP -X Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.7 Piranha Fastening Plate: This is a 23/8 -inch - diameter galvalume-coated steel plate designed to be used with HP -X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.8 HP-XTRA Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.9 Piranha XTRA Fastening Plate: This is a 23/8 -inch -diameter galvalume-coated steel plate designed to be used with HP-XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.10 OMG Inc. RhinoBond Plate: The RhinoBond Plate is a 3 -inch -diameter (76.2 mm), 0.028 -inch -thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP -X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Adhesives: 3.10.1 Sure -Seal 90-8-30A: Sure -Seal 90-8-30A is a high- strength, solvent -based contact adhesive used to adhere EPDM membranes to the insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m /L). The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base 120 is a high-strength, water-based contact adhesive used to adhere EPDM and TPO membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 M2 /L). The adhesive is supplied in 5 -gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex PVC and Sure -Flex Low VOC PVC Bonding Adhesives are high-strength, solvent -based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m /L). The adhesives are supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 M2 /L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high-strength, solvent -based contact adhesive used to adhere membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m / L). The adhesive is supplied in 5 -gallon (18.9 L) containers with a shelf life of one year. 3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, Flexible FAST and FAST Bag -in -a -Box Adhesives are two -component polyurethane adhesives used to adhere FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 M2 /L). The adhesives are supplied in 15-gall,m (56.7 L) and 50 -gallon (189 L) drums, cartridge tubes or cylinders, and have a shelf life of one year. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements: for impact resistance in IBC Section 1504.7, based on testing in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer's published installation instructions and this report. The -nanufacturer's published installation instructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be dean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All mat3rials must be protected against contact with incompa3ible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which tie single -ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations c1 the roof covering must be flashed and made weather tight in accordance with the requirements of the membrane! manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, PVC, and TPO single -ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E 108 and UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support ant secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: ■ New uninsulated systems installed only over existing uninsulated assemblies. ■ New insulated systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PV--, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. ESR -1463 I Most I/Ifidely Accepted and Trusted Page 4 of 10 Metal edge securement for roofing systems must be designed in accordance with ANSI/SPRI ES -1, complying with IBC Section 1504.5. The edge securement for mechanically attached membranes was tested in accordance with ANSI/SPRI ES -1 Test REA, using Carlisle SecurEdge 300 [0.050 -inch (1.27 mm) 3003 aluminum] and Carlisle SecurEdge 3000 [0.040 -inch (1.02 mm) 3003 aluminum] fascia systems. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum, allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer's published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturer's installation instructions and this report. 5.2 The adhered and mechanically fastened single -ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R314.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Table 4. 5.6 The allowable wind uplift pressures listed in Table 4 are for the roof covering system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. 5.8 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi, under a quality control program with inspections by UL LLC (AA -668). 5.9 For buildings under the IBC, above -deck thermal insulation board must comply with the applicable standards listed in Table 1508.2 of the IBC. 6.0 EVIDENCE SUBMITTED Data. in accordance with ICC -ES Acceptance Criteria for Membrane Roof Covering Systems (AC75), dated April 2007, (corrected December 2008). 7.0 IDENTIFICATION Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec Incorporated) or the name of the additional listee, the manufacturer's address or plant code, the ICC -ES evaluation report number (ESR -1463), and the name or label of the inspection agency (UL LLC). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the. following codes: ■ BOCe National Building Code/1999 (BNBC) ■ 1999 Standard Building Code® (SBC) ■ 1997 Uniform Building Code'rm (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: 3.8 Flashing: Flashing must be provided in accordance with SBC Section 1503.2, BNBC Section 1508.1 and UBC Section 1509, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in BNBC Section 1505.4.2, and SBC Section 1504.6, based on testing in accordance with FM 4470. 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 8.0 of this report, subject to the following conditions: See Sections 5.1 through 5.8, except revise Section 5.3 to read as follows: 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with BNBC Section 2603.4.1.5, SBC Section 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as applicable. ESR -1463 1 Most Widely Accepted and Trusted Page 5 of 10 0'fioli:l 00tion 2 A Ix w*14M _vd- ali a� FIGURE 1—INSPECTION AGENCY LABEL ESR -1463 I Most Widely Accepted and Trusted Page 6 of 10 TABLE 1—PRODUCT NAMES CARLISLE PRODUCT MULE -HIDE PRODUCT WEATHERBOND PRODUCT VERSICO PRODUC— KELLY COJ NAME NAME NAME NAME 2001 INC. PRODUCT NAME Sure -Seal Mule -Hide Standard WeatherBond RBR EPDM Versigard EPDM Membrane Sure -Seat FR Mule -Hide FR EPDM WeatherBond RBR FR EPDM Versigard Nonreinforced C-EPDM-C Membrane EPDM Sure -Tough Reinforced Mule -Hide Standard WeatherBond RBR Standard Versigard Reinforcec C-EPDM-CR Reinforced EPDM Reinforced EPDM Membrane Sure -Tough FR Mule -Hide FR Reinforced VersigardFR Reinforced C-EPDM-CR Type 1 Reinforced EPDM Sure -White Mule -Hide White -on- WeatherBond RBR White, EPDM Versigard Nonreinforced EPDM RF- White Black EPDM Membrane EPDM -White Sure -Weld Mule -Hide TPO-c WeatherBond PRO TPO Versiweld Reinforced TPO / White Membrane TPO Sure -Weld HS Mule -Hide TPO-c (FR) - Versiweld ES SAT-TPO Mule -Hide SA-TPO WeatherBond PRO PAS TPO Versiweld QA TPO Sure -Weld EXTRA Mule -Hide TPO-c Extra WeatherBond PRO TPO Versiweld PLUS Membrane Sure -Weld HS EXTRA Mule -Hide TPO-c Extra Versiweld ES PLUS (FR) - Sure -Weld FleeceBACK Mute -Hide TPO-c Fleece Versiweld VersiFleece Back Sure -Flex Mule -Hide PVC WeatherBond PRO PVC VersiFlex Reinforced Membrane PVC Membrane Sure -Flex FRS Mule -Hide FRS PVC VersiFlex FRS Membrane - Reinforced PVC Membrane Sure -Seal 90-8-30A Mule -Hide Bonding WeatherBond RBR LC -60 Bonding G200SA Yellow 2001 Inc. Bonding Bonding Adhesive Adhesive Adhesive Substrate Adhesive Adhesive Sure -Seal Aqua Base 120 Mute -Hide Water -Based Aqua Base 120 Bonding Adhesive Aqua Base 120 Bondirg Bonding Adhesive Bonding Adhesive Adhesive Sure -Weld Bonding Mule -Hide TPO-c WeatherBond PRO TPO Bonding Versiweld Bonding Adhesive Bonding Adhesive Adhesive Adhesive Sure -Weld Low VOC Mule -Hide TPO-c Low Versiweld LOW VOC Bonding Adhesive _ VOC Bonding Adhesive Bonding Adhesive Sure -Flex PVC Bonding Mule -Hide PVC Bonding WeatherBond PRO PVC Bonding VersiFlex PVC Bonding Adhesive Adhesive Adhesive Adhesive Sure -Flex Low VOC PVC Mule -Hide Low VOC VersiFlex Low VOC PVC Bonding Adhesive PVC Bonding Adhesive Bonding Adhesive FAST 100 Adhesive Mule -Hide SP -100 FAST 100 Adhesive Adhesive FAST 100 LV Adhesive - Mule -Hide SP -100 -LT FAST 100 LV Adhesive Adhesive ESR -1463 1 Most Widely Accepted and Trusted Page 7 of 10 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEM_d2'5 SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE/MAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Any of the following insulations, Sure -Weld, Spectro-Weld -'/4:12 1 -inch min. to 6 -inch max. Sure -Seal, Sure7ough, Sure -White, Sure - thickness: Carlisle "SecurShield Seal FleeceBACK Sure -Weld HS, SAT-TPO, 1 A Noncombustible -Polyiso", "Polyiso HP -H", Hunter Sure -Weld Fle?c eBACK1'Spectro-Weld Panels "H -Shield" or FleeceBACK - /2:12 "H -Shield -CG" Sure -White FleeceBACK, Sure -Flex, Sure - s Flee FRS - /4:12 1/2 -inch -thick fiberboard°,'/2 inch -thick fiberboard or barrier a Sure -White FleeceBACK /4:12 board (see Section 3.6) over 5- Sure -Seal, Sure -Tough - 1:12 2 A Noncombustible — inch max Insulfoam EPS3,'/2- Sure -White, Sure -Seal FleeceBACK, Sure - inch -thick fiberboard or barrier Weld, Spectro-VIfeld, Sure -Weld HS, SAT - board (see Section 3.6) over TPO, Sure -Weld FleeceBACK, Spectro-Weld System No. 1 insulations FleeceBACK, SureI Flex, Sure -Flex FRS - 1 /2:12 Sure -White FleeceBACK-3/4:12 Noncombustible or Sure -White, Sure -Seal FleeceBACK - 11/2:12 Combustible - min. Sure -Tough, Sure�Weld, Spectro-Weld, Sure - 3 A 15/32 -inch -thick Barrier board — Weld FleeceBACK, Spectro-Weld plywood or min. (see Section 3.6) FleeceBACK - 3:12 7/16inch-thick OSB. Sure -Weld -iS, SAT-TPO - 4:12 Sure -Seal FR, Sure -Flex, Sure -Flex FRS - unlmited slope Any of the following insulations, Sure-Weld_3pectro-Weld -'/4:12 Combustible - min. Barrier board 1 -inch min. Sure -Seal, Sure -Tough, Sure -White, Sure - t5/32 -inch -thick (see Section 3.6) or to 6 -inch max. thickness: "SecurShield Seal FleeceBACK Sure -Weld HS, SAT-TPO, 4 A plywood or min. ply Slip sheet: 2 layers ' Carlisle Polyiso", Polyiso HP Sure -Weld FleeceBACK, Spectro-Weld Flee(----BACK/2:12 7 ch thick OSB. (see Section 3.7) -H", Hunter Panels "H -Shield" or Sure -White FleeceBACK, Sure -Flex, Sure - "H -Shield -CG" Flee FRS -3/4:12 Combustible - min. ,s Any of the following insulations, Sure -Weld, Spectro-Weld,Sure-Weld HS, 5 C /32 -inch -thick _ 2 -inch min. to 6 -inch max. SAT TPO, Sure -Flex, Sure Flex FRS - plywood or min. 7/1 plywood thickness: Carlisle "Polyiso HP- unlimited slope OSB. H" or Hunter Panels "H -Shield" Single layer of minimum 3.0" or' double layer of minimum 1.5" 6 A Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, anc TPO Membranes -'/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1.9" 7 B Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, anc TPO Membranes -'/2:12 Hunter Panels "H -Shield -CG" For SI: 1 inch = 25.4 mm. ' All foam plastic insulation must be UL-classfied foamed plastic for roofing systems, and must be limited to the makimum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is lesa. 'See Section 3.10 for adhesive application rate. 3 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slopel :12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. °Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. 1/2:12. 5When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. I ESR -1463 I Most Widely Accepted and Trusted Page 8 of 10 TABLE 3—FIRE CLASSIFICATION ASSEM BUES— MECHANICALLY FASTENED ROOFING SYSTEMS" SYSTEM ROOF DECK BARRIER BOARD INSULATION' U=MBRANE/MAX. ROOF NO. CLASS OR SUP SHEET SLOPE Any of the following insulations, 1 -inch min. to Sure -Tough, Sure -Weld, 1 A — 6 -inch max. thickness: Carlisle "SecurShield Spedro-Weld, Sure -Flex, Sure - Noncombustible Polyiso" or "Polyiso HP -H", Hunter Panels "H- "H Flex FRS - /2:12 -Sure-Weld HS - 11/212 Shield" or -Shield -CG" Sure -Tough FR - 2:12 1/2 -inch -thick fiberboard 3. 1/2 -inch -thick Sure -Tough, Sure -Weld HS, fiberboard or barrier board (see Section 3.6) Sure: Flex, Sure -Flex FRS - 1:12 2 A Noncombustible — over 5 -inch max Insulfoam EPS2,'/2-inch-thick Sure -Weld, Spectro-Weld - fiberboard or barrier board (see Section 3.6) 1'/2:12 over System No. 1 insulations Sure -Tough FR - 31/2:12 Sure= -Weld, Spectro-Weld, Sure - 3 A Noncombustible — To 5 -inch max: Insulfoam SP Weld HS, Sure -Flex, Sure -Flex FRS -'/2:12 Noncombustible or Eure-Tough, Sure -Weld, Combustible - min. bo Spectro-Weld - 3:12 4 A 15/3, inch -thick (see der 3a6) — Sure -Tough FR - 3'/2:12 plywood or min. Sure -Weld HS, Sure -Flex, Sure - '/,6 -inch -thick OSB. Flex FRS - unlimited Combustible - min. Barrier board Any of the following insulations, 1 -inch min. Eure-Tough, Sure -Weld, 15/szinch-thick (see Section 3.6) to 6 -inch max. thickness: Carlisle Spedro-Weld, Sure -Flex, Sure - 5 A plywood or min or Slip sheet: 2 "SecurShield Polyiso" or "Polyiso HP -H", , Flex FRS - /2:12 /,inch thick OSB.. 7/16-inch-thick layers, see Section y (3.7) Hunter Panels "H "H Sure -Weld HS, 1'/2:12 -Shield" or -Shield -CG" Sure -Tough FR - 2:12 Combustible - min. Sure -Tough - 1:12 '5 /o Slip sheet, 2 layers Sure -Tough FR, Sure Weld, 6 A d orr min. plywood (see Section 3.7) — Spedro-Weld, Sure -Weld HS, 7/1 �inch thick OSB. Sire -Flex, Sure -Flex FRS - 1'/2:12 Combustible - min. Sura -Tough, Sure -Tough FR, 7 B 15/32 -inch -thick Slip sheet, 1 layer — Sere -Weld, Spectro-Weld, plywood or min. (see Section 3.7) Sure -Weld HS, Sure -Flex, Sure - '/,s -inch -thick OSB. Flex FRS - 11/2:12 Combustible - min. Any of the following insulations, 2 -inch min. '5/3zinch-thick to 6 -inch max. thickness: Carlisle Sere -Weld, Spedro-Weld, 8 C plywood or min. — "SecurShield Polyiso" or "Polyiso "H Sure -Weld HS, Sure -Flex, Sure- ure- 7 7/is-inch-thick /,5 inch thick OSB. HP -H", Hunter Panels -Shield" or H -Shield Flex FRS - unlimited CG" Single layer of minimum 3 -inch or double 9 A Combustible — layer of minimum 1.5 -inch Carlisle -'-:PDM, PVC, and TPO "SecurShield Polyiso" or Membranes -'/2:12 Hunter Panels "H -Shield -CG" Single layer of minimum 1.9 -inch Carlisle 10 B Combustible — "SecurShield Polyiso" or Hunter Panels "H- [;-:PDM, PVC, and TPO Shield -CG" or single layer of an inverted G3 Membranes -'/2:12 cap sheet. For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboardl over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/2:12. °When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR -1463 I Most Widely Accepted and Trusted Page 9 of 10 TABLE 4—WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°'' . SYSTEM MAXIMUM DECKS INSULATION 5 MEMBRANE MEMBRANE MAXIMUM MAXIMUM NO. ALLOWABLE FASTENING FASTENER FASTENER WIND UPLIFT SPACING ROW (psf) (inches) SPACINGS Foam plastic insulation'•z 1 45 Noncombustible 112-inch-thickSure fiberboard or Tough HP -X Fastener & Metal Fastening Bar 12 6 ft 6 inches barrier board (See Sect. 3.6) 2 75 Noncombustible Same as System No. 1 Sure -Tough HP -X Fastener & Metal Fastening Bar 6 6 ft 6 inches 3 52 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & Polymer Seam Plate 6 9 ft 6 inches 4 45 Noncombustible Same as System No. 1 Sure -Tough Sure-Tde Fastener & ST Fastening Bar 12 9 ft 6 inches 5 30 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 12 9 It 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No. 1 Sure -Tough (75 mil) HP Fastener & Polymer Seam Plate 6 9 ft 6 inches Sure -Weld, HP -X or HP -Xtra 7 45 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 7 ft 6 inches Spectro-Weld or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure -Weld, Sure -Weld EXTRA, or HP -Xtra Fasteners with 12 9 ft 6 inches Spectro-Weld Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 9 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha or Piranha Xtra 6 9 ft 6 inches Spectro-Weld Plates Sure -Weld, HP -X or HP -Xtra 10 67 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 7 It 6 inches Spectro-Weld or Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 11 30 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 11 It 6 inches Spectro-Weld or Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 12 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 11 It 6 inches Spectro-Weld or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with Piranha Plates 6 6 ft 4 inches 14 83 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with Piranha Plates 6 2 ft 11 inches HP -X or HP -Xtra 15 30 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates HP -X or HP -Xtra 16 45 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with Piranha Plates 12 2 ft 11 inches 18 45 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with OMG RhinoBond Plates 1 per 5.3 ftz N/A 19 60 Noncombustible Same as System No. 1 Sure -Weld Fasteners with 1 per 4 ftz N/A OMG RhinoBond Plates For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa. 'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShielc Polyiso","Polyiso HP -H" Hunter Panels "H -Shield" or Hunter Panels "H -Shield- CG". 2All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the n-aximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is lass. 'Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f.) of 2500 psi. See Section 5.6 of this report. °For existing metal roofing, the assemblies listed must be installed by fastening through the roofing and into structural members (purlins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. 5 U Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulatio-is (max slope1:12) or below min. 1/2 -inch -thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible decks. 6Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboErd over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12. ESR -1463 I Most Widely Accepted and Trusted Page 10 of 10 ' Table 4 footnotes cont'd When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, ac applicable. 8 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must to determined accordingly. TABLE 5—WIND RESISTANCE — ADHERED ASSEMBLIES5 SYSTEM ALLOWABLE DECK INSULATION / MIN. THICKNESS'"3 INSULATION MEMBRANE NO. WIND UPLIFT FASTENING TYPE (FIELD) (psf) RATE 1 45 Combustible or 1/2 Inch fiberboard °, 15/32 inch OSB, or barrier board (See 1 per 2 112 EPDM, PVC and TPO Noncombustible Section 3.6) Membranes 2 45 Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter Panels "H -Shield" "H -Shield -CG"/ 1.4 inch 1 3.2 ft2 EPDM, PVC and TPO Noncombustible or with'/2-inch Securock ooverboard (optional) per Membranes 3 45 Combustible or Carlisle "Polylso HP -H" or "SecurShield Potyiso"; Hunter Panels "H -Shield" or "H -Shield -CG" / 2.0 inch 1 4 ft2 EPDM, PVC and TPO Noncombustible with 5/B -inch Securock ooverboard (optional) per Membranes 4 68 Combustible or Carlisle "Potyiso HP -H" or "SecurShield Polytso"; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels "H -Shield" or "H -Shield -CG"/ 1.0 inch 5 75 Combustible or Carlisle "Polyiso HP -H" or "SecurShleld Polylso"; Hunter Panels "H -Shield" "H -Shield -CG"/ 2.0 inch 1 1.6 ft2 EPDM, PVC and TPO Noncombustible or with'/2-inch Securock coverboard (optional) per Membranes 6 120 Combustible or Carlisle "Polyiso HP -H" or "SecurShleld Polylso"; HunterTPO "H "H 1 per 1 tt2 Membranes; EPDM membranes (with Noncombustible Panels -Shield" or -Shield -CG" / 2.0 inch noncombustible deck only) Combustible or Carlisle "Polyiso HP -H" or "SecurShleld Polyiso"; Hunter 7 128 Noncombustible Panels "H -Shield" or "H-Shleld-CG" / 2.0 inch 1 per 1 ft2 EPDM and TPO Membranes with'/2-inch Securock ooverboard (optional) Combustible or Carlisle "Polyiso HP -H" or "SecurShield Polyiso"; Hunter 8 135 Noncombustible Panels "H -Shield" or "H -Shield -CG"/ 2.0 inch 1 per 1 ft2 FleeceBACK Membranes with'/2-inch Securock ooverboard (optional) 9 143 Combustible or Noncombustible 1/2 inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes For SI: 1 inch = 25.4 mm; 1 It = 0.305 m; 1 psf = 47.88 Pa 'All foam plastic insulation must be UL -classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is Ib -ss. 2Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f'.) of 2500 psi. See Section 5.6 of this report. 3UL Classified EPS may be installed below min. 1 -inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H -Shield HD (max slope 2:12) on noncombustible dEcks. °Carlisle SecurShield HD or Hunter Panels H -Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to 1/2:12. 5When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. For reroofing or recovering, installation must be irb accordance with IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable