BSOL2017-0025r
FJ
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
INFINITY ENERGY, INC
1108 TINKER RRD #150
ROCKLIN, CA 95765
C��iGtAp 4 4 a IUCl/ VOICE (760) 777-7125
FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 12/27/2017
SOLAR/RESIDENTIAL LESS THAN 1OKW Owner:
BSOL2017-0025 JAMES GREEN
51505AVENIDA HERRERA 51505 AVENIDAHERRERA
773132013 LA QUINTA, CA 92253
GREEN / 2.9kW PV SYSTEM - (10) 290W PANELS+MICRO INVERTERS
$9,000.00
DEC 2 / 2011
I CITYOFLAOUINTA
COMMUNITY DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION '
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B. CSO License No.: 998627
Date: / G —C. / —! 7— Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county.that requires a permit to construct, alter, Improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or Improves thereon, and who does the.work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or.improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
Contractor:
INFINITY ENERGY INC
1108 TINKER RCJAD STE 150
ROCKLIN, CA 95765
(888)244-2513
Llc. No.: 998627
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one Df the following declarations:
I have and will maintain a certific.te of consent to self -insure for workers'
compensation, as provided for by Section 37)0 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' :ompensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE =UND Policy Number: 9146613
I certify that in the performance cf the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with.those provisions. p.
Date: 12 �� —� L Applicant:
WARNING: FAILURE TO SECURE WORKERS' CDMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,600). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKN :)WLEDGEMENT
IMPORTANT: Application Is hereby made to :he Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or.
following issuance of this permit.
2. Any permit issued as a result of this appication becomes null and void if work is
not commenced within 180 days from date cf issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county orlinances and state laws relating to building
construction, and hereby authorise representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: —Signature (Applica it or Agent): 'ALL
Date: 12/27/2017
. Application Number:
BSOL2017-0025
Owner:
Property Address:
51505 AVENIDA HERRERA
JAMES GREEN
APN:
773132013
51505 AVENIDA HERRERA
Application Description:
GREEN / 2.9kW PV SYSTEM - (10) 290W PANELS+MICRO INVERTERS
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$9,000.00
Applicant:.
Contractor:
INFINITY ENERGY, INC
INFINITY ENERG" INC
1108 TINKER RRD #150
1108 TINKER ROAD STE 150
ROCKLIN, CA 95765
ROCKLIN, CA 95765
(888)244-2513
----------- -------------------------------------------------
Llc. No.: 998627
----------------------------------
Detail: 2.9kW SOLAR ARRAY - (10) 290W SUNMOBILE PANELS+ENPHASE IQ-6 MICROINVERTERS [180SF] 2016 CALIFORNIA ELECTRICAL CODE.
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT CITY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
f Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PV SYSTEM LESS THAN 10KW
101-0000-42403
0
$26.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PV SYSTEM LESS THAN 10KW PC
101-0000-42600
0
$26.01
Total paid for ELECTRICAL: $52.02
DESCRIPTION
ACCOUNT,
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$98.83
Total Paid for PERMIT ISSJANCE: $98.83
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Mono Multi
Solutions
Tlilr_
PLUS'
60 CELL
MONOCRYSTALLINE MODULE
i7Ms2I, ii
POWER OUTPUT RANGE
18.07
MAXIMUM EFFICIENCY
0~+5W
POSITIVE POWER TOLERANCE
is a loading global n)-inufaclurcr of
n.•agon._rafioi;t�hrlcicltaicproducf�,
bclio';c• cic_o coop!ration with
cur partnsre i> crilical to cee s_ Plith
pr;^nee around th glob Trin
i- u'uc to pmviJc r>ccptionol sin-ia:
o ach eu-lemer in each mar''et and
uppl_rn_�nl cur innovcilivo. rolinbla
pr,ducts v:ilh Ih.- bac:•:ing of Trina
a-, e ,iron-, b-inkob1c partner.
_ut, cc) mmiIfed to buiIding -tratc,gic,
nxiluolly; k-' ficiol collaELcration % ith
n�tall r, dwclop^r,, dctribulois and
other parinor. --I-
.,ih^_ bart:bonc cf our
:Poiedsuee ;_ in driving Srnaii En^rqy
Tcaothor,
Trina Solar Limited
., ; .frinasolar.com
LINEAR PERFORMANCE WARRANTY
ra�7eu Yr.,-d:ac�;nr,a�ey .•r �� ,� r:. v____ru,�
Vnesolar
Smart EnergyTogedi=r
r• i'/laximize limited space with top -end efficiency
• Up to 130 W/mr' po• r_-r density
• Lo%-., tn,.rrn. l coofiicients for area
ter energy production at high
ofo.ratinq. temperaturms
Flighty reliable clue to stringent quality control
Ovcr30 in-hou_,.tze-ts �UV, C, HF anti rnan' enore)
• !n•hou,o testina noC•s 4uvr1r6 cc-,rIiIc-lli ;n requir_ trionl>
• 100; EL double in3p^_clion
Certified to `°7itnstclnd challenging environmental
condliilons
• 2.100 Pa rind load
• 54100 Pa snot; load
• 35 rnm hail stones at 97 ilm/h
Co-y-iPrethEnmve pyod uc7s and sysfeni cerfisicates
• IEC 61215/ IEC' 61730/ UL 1703/ IEC 61701/IEC 62716
• ISO 7001: C)uality PAanagcrnonf System
• ISO 14001: EnvironmcnIoI [1,ana,�ornontSy f:ai
• ISO 140Grconhouse Ga�cs Ernissions V�Drificalion
OHSAS 15001: Oc :upaiion Health anal Sof+ay �A4anagmment Sys[(-rn
C ULaaS N C E t *
a 7 LISTED pV CYCLE
41
THE A { ' MAX "$LUs MODULE
PRODUCTS POWER RANGE
iGIV-MI DSA "Milt)
sxk-�=r�s.�atlti �raa:�waroT
DIMENSIONS OF PV MODULE
unil:mm/inches
23 941137.0
rp9.12 Ju—ton fiat —
• Wlallnll I_lok -
Namaplatc ,
8
o A A
At r
6-04 3
Grounding Roh
I
12-Dram Role
180/7.1
992/39,1
Back VI..
Silicon Sealant
11/0.43
laminale
Frame
3511,38
A•A
I-V CURVES OF PV MODULE(295W)
l2
Y
r r6a°1'zr•-
r 600vY/m,
s
e
2 roow/.,nr
1
0
s to is 9p 25 ]o os 40 45
venw.M
P-V CURVES OF PV MODULE(295W)
ELECTRICAL DATA (STC)
k77B :iTa :2eB :PE5
:29T ;2
I$+r�-Dlij�./Itltd�r�xY��rcrk�;J f�7-:v.�
fbt�iir6wlre.'rt�vuer`J(dli>a sf/uGiiW1 31D �i4i �[,7 319
W2 325
l�tmfiimumRmw�QYrcresitJl—it%91 ?8fH6 IR?,tb M&4 11771
79111 79
mIIir::aifVdtesV4r;(VJ 38.4 387 39.0 393
312:5 39,7
Btkc7dF2'iir> iitGur�ci�lls`((,WJ TAB '!k 79.35 99AS
9?M 94.;i5
.'eaLn.*IJr=l:firc®nc;'gh �G J It6.5 ITS 1L71 17.4
177
5C-_': r+crnlar-.� �7n• Arifn-'..'C.�IiTenlPeryt:rre"%i.•1pe.lgt�.xD:fl3_
ELECTRICAL DATA (NOCT)
Ri'sri^t•rrn=9.re=.:Pwx]IKj J 2M 2M 279 2:12
216 '22D
1nL�iatrsnFaK®rVrmRacJe•vr�((Y!} 2&W 292 2V4 2M
293 32
M�i� rn,i Lur it 1,�(toN} S'% 7m 71D 7-17
723 7-M
�Jpen imuAaudlimgeYY�clt� I 337 36ID W3 36-
3&-7 3s-V
Short CiFr-u!f •CsmreritI-, i(A) 741 7te 735 7A3
7.167 7--n
3Y� 1rrJ�CI'L^SlY$�Jl4�ef!�.?lTflb18r11i9�grj1'J���[.10.rRld ��j �'Ri�6
MECHANICAL DATA
.solar Calls MOr--Widlline 156 - 136 mm 161n.h sJ
C.>aIt Q: r�-to-. BD 2aells jb r ➢OJ
,MOd leDirre"iOns7SSD=992-35;mm(G3Ox391x1-38ccfireS)
w9h1 18-6 ikg J41-D 11)
Glass 32.mm ID-13:nchesJ. hiighTrcrr mC.Dn, AR Coated Tempered Gla,
saouheeT VVh-.iePD,35&ckX 11_Blackf >2sto)1
Fnxne Block JDDa5A-3611n, DD05&USM)
9"Baff 'dP 467 orlP 68 toted
Cables PiYotravWLaitT v'a!ogy Cable 4Mmm- (O_II6 vlches J-
1000 m:n p91 oases)
CarIne'dar MC4CnrrrpullieorAmpher.01H4JUfX
F-rte Type Type I Or Type 2
TEMPERATURE RATINGS MAXIMUM RATINGS
Y
N;!7E rrcl Opercfmg Cell
Iema—uture.(NOCT] 44°CJ±2aC) Operational Temperature
-40-+WC
Te1P18m ure COefr%cent of P.ux - 0-3M-C M4ndnum System Voltoge
00
1000V DC (lRJ
Temperature Coefficient of Vac : - 0.29%/°C Mmc Series Fuse Ruling
1
Temperature Coefficient of Isc 0.05%/°C
WARRANTY
10 year Product Workmanship Warranty
25 year Linear Power Warta my
(Please refer to Product wanonly for details)
PACKAGING CONFIGURATION
Modules per box: 30 pieces
z
Modules per 40' container: 840 pieces
0 ; ID 1s To }s 3o Is 4a 45
ve6.oyv1 �
'i�rin�$O�ar CAUTION: READ SAFETY A:NOINVAltgt INSTRUCTIONS BEFORE USING THEpRODUCT.
■r A 7016 Trina Solar Linnitett. F1t tights rwerrea. Specifications InclvBed in this dala:hout are subject to change without notice,
Smart Energy Together
Enphase
IQ6and IQ6+
III icroinverters
The high-powered smart grid -ready
Enphase IQ 6 Micro' and Enphase IQ 6+ MicrOT1
dramatically simplify the installation process while
achieving the highest efficiency for module -level
power electronics.
Part of the Enphase IQ System, the IQ 6 and IQ
6+ Micro integrate seamlessly with the Enphase
IQ EnvoyT"', Enphase Q AggregatorTM, Enphase IQ
BatteryTI, and the Enphase EnlightenT"' monitoring
and analysis software.
The IQ 6 and IQ 6+ Micro extend the reliability
standards set forth by previous generations and
undergo over a million hours of power -on testing.
Enabling Enphase to provide an industry -leading
warranty of up to 25 years.
Easy to Install
Lightweight and simple
Faster installation with improved two -wire
cabling
Built-in rapid shutdown compliant (NEC 2014)
Productive and Reliable
Optimized for high powered 60-cell and 72-
cell* modules
More than a million hours of testing
Class II double -insulated enclosure
Smart Grid Ready
Complies with fixed power factor, voltage and
frequency ride -through requirements
Remotely updates to respond to changing
grid requirements
Configurable for varying grid profiles
CE4TIFIEo
* The IQ 6+ Micro is required to support 72-cell modules
Enphase IQ 6 and IQ 6+ Microinverters
INPUT DATA (DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US
Commonly used module pairings' 195 W - 330 W + 235 W - 400 W +
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 62 V
Peak power tracking voltage 27 V - 37 V 27 V - 45 V
Operating range 16 V - 48 V 16 V - 62 V
Min/Max start voltage 22 V / 48 V 22 V / 62 V
Max DC short circuit current (module Isc) 15 A 15 A
Overvoltage class DC port II II
DC port backfeed under single fault 0 A 0 A
PV array configuration
1 x 1 ungrounded array; No additional DC side protection required;
AC side protection requires max 20A per branch
circuit
OUTPUT DATA (AC)
IQ6-60-2-US AND IQ6-60-5-US
IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US
Peak output power
240 VA
290 VA
Maximum continuous output power
230 VA
280 VA
Nominal voltage/range2
240 V / 211-264 V 208 V (10) / 183-229 V
240 V / 211-264 V 208 V (10) / 183-229 V
Nominal output current
0.96 A 1.11 A
1.17 A 1.35 A
Nominal frequency
60 Hz
60 Hz
Extended frequency range
47 - 68 Hz
47 - 68 Hz
Power factor at rated power
1.0
1.0
Maximum units per 20 A branch circuit
16 (240 VAC)
13 (240 VAC)
14 (single-phase 208 VAC)
11 (single-phase 208 VAC)
Overvoltage class AC port
III
III
AC port backfeed under single fault
0 A
0 A
Power factor (adjustable)
0.7 leading ... 0.7 lagging
0.7 leading ... 0.7 lagging
EFFICIENCY
_
@240 V @208 V (10)
@240 V @208 V (10)
CEC weighted efficiency
97.0 % 96.5 %
97.0 % 96.5 %
MECHANICAL DATA
Ambient temperature range
-400C to +65°C
Relative humidity range
4%to 100% (condensing)
Connector type
MC4 or Amphenol H4 UTX
Dimensions (WxHxD)
219 mm x 191 mm x 37.9 mm (without bracket)
Weight
1.5 kg (3.3 Ibs)
Cooling
Natural convection - No fans
Approved for wet locations
Yes
Pollution degree
PD3
Environmental category / UV exposure rating
Outdoor- NEMA 250, type 6 (IP67)
FEATURES
Communication
Power line
Monitoring
Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy
Compliance
UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 640.12 and C22.1-2015 Rule 64-216' Rapid Shutdown of PV Systems, for AC
and DC conductors, when installed according manufacturer's instructions.
1. No enforced DC/AC ratio See the compatibility calculator at enpha.se com en-LL ort module_compat �j ty
2. Nominal voltage range can be extended beyond nominal if required by the utility.
To learn more about Enphase offerings, visit enphase.com
Snap rack -
Solar Mounting Solutions
Series 100 Residential Roof Mount System
The SnapNrack Series 100 Roof Mount System is engineered to optimize material use,
labor resources and aesthetic appeal. This innovative system simplifies the process
of installing solar modules, shortens installations times, and lowers installation costs;
maxinnizing productivity and profits.
The Series 100 Roof Mount System bCaStS unique, pre -assembled, stainless steel "'Snap -
in," hardware and watertight flash attachments. This system is installed with a single
tool. No Cutting cr drilling means less rail waste. It is fully integrated with built-in wire
Tian` gen-ient, solutions for all roof types, one -size -fits -all features, and can withstand
extreme environmental conditions. Series 100 is listed to UL Standard 2703 for
Cro�or�dir c!3onding, Fire Classification and Mechanical Loading. UL 2703 Certification
and Compliance ensures that SnapNrack installers can continue to provide the best in
clan; installations in quality. safety and Efficiency.
0 Appealing design with built-in aesthetics
0 No grounding lugs required for modules
* All bonding hardware is fully integrated
Rail splices bond rails together, no rail
jumpers required
• No drilling of rail or reaching for other tools
required
* Class A Fire Rating for Type 1 and 2 modules
System Features Include
Snap in Single Tool Easy No Cutting
Hardware Installation Leveling or Drilling
Snap rack -
Solar Mounting Solutions
5talnnss poll+•ltts
5pIFi-to[k Washer
Banding Adlwtabe,
End Clarnp Top
Elvnding Adjustable
End Clamp Bottam
Bonding Adjustable
End Clamp
242-020G2
St sinless Steal
Bolt with Split -
Lock Washer
Bonding
Mid Clamp
— Bonding
Channel Nut
Bonding Mid Clamp
r 242-02053
Bonding Splice
Insert
( Splice
Base
_:tainles4 Hardware with
Split -Lock Washers
Bonding Standard
Rail Splice
. 11:
Standard Rail
015-09816
Bonding
Channel Nut
Stainless
Bolt with
Split Lock
Washer
Ground Lug
242-02101 12-6 AWG -
Copper Wire
_ Ground Lug Assembly _
(ONE REQUIRED PER ROW OF
MODULES)
Universal End Clamp (UEC)
f ~ Wave
_ —UEC Pull Strap
UEC Wedge L. Stainless Steel Bolt
with Flat Washer
Universal End Clamp
242-02215
Standoff
Clamp
Assembly
Rubber— Serrated stainle=--s —r Channel — Channsl Nut.
Rain Collar Steel Flange Nut Nut
Stainless
Serrated slatnlem Flange Nut
Steel Flange Bolt - 92 Degree �- _— sta"ess
Mill Finish-- Standoff L Foot Flange
Bolt
y,.
- All Purpos9
_ L Font
Mill Finish
Standoff _
Base (1-Hole —Metal Runf
Base Shown) Mill Finish — - L Foot Base Assembly
{ L Foot Base • .1 a Flashing
k�f Metal Roof Base
Standoff J L L Foot Base with Flashing with L Foot
242-92057 242-92050 242-02037
• 6000 Series aluminum
Materials • Stainless steel
• Galvanized steel and aluminum flashing
• Silver and black anodized aluminum
Material Finish • Mill finish on select products
• Silver or black coated hardware
Note: Appearance of mill finish products may vary and change over time.
Wind Loads 110 - 190 mph (ASCE 7-10)
Snow Loads 0 - 120 psf
Array Pitch 0 - 60 degrees