BSIG2017-0022At!t
78-495 CALLE TAMPICO T D VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 DESIGN &DEVELOPMENT DEPARTMENT ' FAX (760) 777-7011
' INSPECTIONS (760) 777-7153
BUILDING PERMIT
A licant: DEC 14 2017 Contractor:
pp
PD GROUP DBA SIGNARAMA PO GROUP DBA SI•33NARAMA
41945 BOARDWALK SUITE L CITYOFC,�4LlNTA 41945 BOARDWALK SUITE L
PALM DESERT, CA 92211 PALM DESERT, CA.•92211
COMMUNITY DEVELOPMENT CG"rAALJ�E 1T
(760)776-9907
Llc. No.: 830131
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: D42 C45 / License No.: 8301131
D�� ! Con" tractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License. Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).: i
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for.sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' -
State License Law does not apply to an owner of property who builds or improves.
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under.penalty of perjury one of :he following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 :)f the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: ACE AMERICAN INSURANCE COMPANY Policy Number: RWCC64396857
_.I certify that In the performance of the work for which this permit is issued, I
shall not employ any person in any manner so ar, to become subject to the workers'
compensation laws of California, and agree that if I should become,subject to the
workers'.compensation provisions of Section 3770 of the Labor Code, I shall forthwith
comply with
ytho7 pprov sions.
Da �7% App icant:
WARNING: FAILURE TO SECURE WORKERS'.COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED.THOUSAND DOLLARS ($100,000. IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this :,pplication.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this applicaEion becomes null and void if work is
not commenced within 180 days from date of is:,uance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and star that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize re.presentati-es of this city to enter upon the
above.mentloryd p operty for inspection purposes. r
Da �a y %7 Signature Applicant w Agent): "�
Date: 12/13/2017
Permit Type/Subtype:
SIGN/
Owner:
Application Number:
BSIG2017-0022
HARSCH INV REALTY
Property Address:
78347 HIGHWAY 111
1121 SALMON ST 4TH FL
APN:
604050059
PORTLAND, OR 92253
Application Description:
INFINITY HAIR DESIGN / CHANNEL LETTER SIGN
Property Zoning:
Application Valuation:
$3,000.00
Fn_ T
A licant: DEC 14 2017 Contractor:
pp
PD GROUP DBA SIGNARAMA PO GROUP DBA SI•33NARAMA
41945 BOARDWALK SUITE L CITYOFC,�4LlNTA 41945 BOARDWALK SUITE L
PALM DESERT, CA 92211 PALM DESERT, CA.•92211
COMMUNITY DEVELOPMENT CG"rAALJ�E 1T
(760)776-9907
Llc. No.: 830131
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: D42 C45 / License No.: 8301131
D�� ! Con" tractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License. Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).: i
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for.sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' -
State License Law does not apply to an owner of property who builds or improves.
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under.penalty of perjury one of :he following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 :)f the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: ACE AMERICAN INSURANCE COMPANY Policy Number: RWCC64396857
_.I certify that In the performance of the work for which this permit is issued, I
shall not employ any person in any manner so ar, to become subject to the workers'
compensation laws of California, and agree that if I should become,subject to the
workers'.compensation provisions of Section 3770 of the Labor Code, I shall forthwith
comply with
ytho7 pprov sions.
Da �7% App icant:
WARNING: FAILURE TO SECURE WORKERS'.COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED.THOUSAND DOLLARS ($100,000. IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR N SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this :,pplication.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the Cty of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this applicaEion becomes null and void if work is
not commenced within 180 days from date of is:,uance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and star that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize re.presentati-es of this city to enter upon the
above.mentloryd p operty for inspection purposes. r
Da �a y %7 Signature Applicant w Agent): "�
Date: 12/13/2017
Application Number: BSIG2017-0022
Owner:
Property Address: 78347 HIGHWAY 111
HARSCH INV REALTY
APN: 604050059
1121 SALMON ST 4TH FL
Application Description: INFINITY HAIR DESIGN / CHANNEL LETTER SIGN
PORTLAND, OR 92253
Property Zoning:
Application Valuation: $3,000.00
Applicant:
Contractor:
PD GROUP DBA SIGNARAMA
PD GROUP DBA SISNARAMA
41945 BOARDWALK SUITE L
41945 BOARDWALK SUITE L
PALM DESERT, CA 92211
PALM DESERT, CA.92211
(760)776-9907
------------ ----------------------------------------------------------------------------------
Llc. No.: 830131
Detail: INFINITY HAIR DESIGN CHANNEL LETTER SIGN. PER 2016 CALIFORNIA BUILDING CODE
A
FINANCIAL•• •
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS S61473 FEE
101-0000-20306 0
$1.00
Total Paid foe BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT`
DEVICES, FIRST 20
101-0000-42403
0
$3.25
Total Paid for ELECTRICAL: • $3.25
DESCRIPTION
ACCOUNT.
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WALL/AWNING SIGN, FIRST
101-0000-42404
0
$53.06
Total Paid for SIGN:. $53.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
' ---- , — -- ---
e `r,/
PERMIT9# � 1 Y
- V OU,-
PLAID LOCATION �
I
Project Address: ��3 l ' , I
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
A P N #:
V eA. nr rz v l tM�
Telephone: -76 d -,5-7,f [g//✓ �-5
Patio/Porch SF
Applicant Namc: U!✓ ,
Fire Sprinklers _ SF
.Address:
-
City, ST, Zip: �� 1. W�62,Ci . Gti� 1
Telephone: %6 0 -• J -7g- 6 �✓
Email:}� l
� � Jl Na2sr•�., C-tr".---
Valuation of Project $ J�
'
Contractor Name: �YY1
`S�
New SFD Construction:
Address: Lf L✓) ` J
Conditioned. Space SF
City, St, Zip
• �i �•. 7 Z�� t 1
Garage _ SF
Telephone: -76 d -,5-7,f [g//✓ �-5
Patio/Porch SF
Email: �o rs�n_rn
Fire Sprinklers _ SF
State Lic: • 13 1 City Bus Lic: C� a -o -5-41 q
-
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Construction Type: Occupancy:
Telephone:
Bedrooms:
Stories:
# Units:
Email:.
State Lic: City Bus Lic:
Property Owner's Name:
New Commercial / Tenant Improvements:
Address: e�
Total Building SF
City, ST, Zip . k , �d I c C
Construction Type: Occupancy:
Telephone:
Email�
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
SPATE OF CALIFORNIA
`SIGN LIGHTING µ ,
�s
CEC-NRCC-LTS-0.1-E(Revised 08/16) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTS-01-E
Sign Lighting (Page 1 of 5)
Praleat Name:
Date PrepareM
A. General Information
Project Address:�q � � G✓� � ` � Z,
Location of Sign Outdoor Signs []'Indoor Signs
Phase of Sign Construction 1KNew Signs ❑ Sign Alterations
Type of Lighting Control New Lighting Controls ❑ Replaced Lighting Controls ❑ Not In stalling Lighting Controls
This Certificate of Compliance includes the following components (check all that apply):
❑ Mandatory Measures (Lighting Controls) ❑ Maximum Allowed Lighting Power ❑ Specific Lighting Sources
1. Mandatory Sign Lighting Controls
NOTES:
1. The same responsible person may install both the sign lighting power and the sign lighting contAols, or a different responsible
person may install the sign lighting controls than the responsible person installing the sign lighting power.
2. The Mandatory Measures (sign lighting controls) are required for compliance with the sign ligating Standards. If the person
responsible for installing the sign lighting power is not also responsible for the sign lighting controas, then the owner of the sign,
general contractor, or architect shall be responsible to have the sign lighting controls installed.
3. If more than one person has responsibility for compliance, each responsible person shall prepare and sign a Certificate of
Compliance and an Installation Certificate applicable to the portion of construction for which they ore responsible; alternatively,
the person with chief responsibility for construction shall prepare and sign the Certificate of Compliance Declaration Statement
for the entire construction (e.g. a C-10 contractor may complete parts la and lb on one compliance document and a C-45
contractor may complete parts 20 and 2b on a separate compliance document — the Responsible Designer shall submit the two
compliance documents together for the some complete installation).
I Fjave responsibility for installing the sign lighting controls:
Yes, I have responsibility for the sign lighting controls, and will ❑ No, I do not have responsibility for installing the sign lighting controls.
complete parts la and lb of this compliance document Someone else will complete parts la and lb of this compliance document.
la. Check Yes or No for all of the following statements:
1 �F
There are existing sign lighting controls that comply with the applicable provisions of §110.9 and §330.3
❑ Yes
There are no existing sign lighting controls and I will be installing sign lighting controls that comply with the applicable
provisions of §110.9 and §130.3 k 1-�,
❑ Yes ❑ No
There are existing sign lighting controls that do not comply with the applicable provisions of §110.9and §130.3 and I will be
installing sign lighting controls that comply with the applicprovisions of §110.9 and §130.3
❑ Yes No
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
STATE OF CALIFORNIA
SIGN LIGHTING
CEC-NRCC-LTS-01-E(Revised 08116)
CERTIFICATE OF COMPLIANCE
Sign Lighting
Project Name:
Prewired: /
VIMISSION
NRCC-LTS-01-E
(Page 2 of 5).
lb. Mandatory Sign Lighting Controls
If the person signing the Certificate of Compliance Declaration Statement on this NRCC-LTS-01-E is responsible for complying with
the sign lighting control requirements, that person shall answer all of the following questions:
If there are construction documents, indicate where on the building plans the
mandatory measures (sign lighting control) note block can be located:
1 switch cont All indoor sign lighting is controlled with an automatic time -switch control or astronomical time- Y N NA
switch control.
§130.3(a)2A. All outdoor sign lighting is controlled with a photocontrol in addition to an automat -t time- O O
switch control, or an astronomical time -switch control. Y N NA
2 EXCEPTION to Section 130.3(a)2A: Outdoor signs in tunnels, and signs in large permanent) covered outdoor A O O
areas that are intended to be continuously lit, 24 hours per day and 365 days per year. y Y NA
§130.3(a)2B. All outdoor sign lighting that is ON both day and night is controlled with a dimmer that provides O
the ability to automatically reduce sign lighting power by a minimum of 65% during nighttime hour. Signs that Y N NA
3 are illuminated at night and for more than 1 hour during daylight hours shall be considered ON boil day and O O
night.
EXCEPTION to Section 130.3(a)2B: Outdoor signs in tunnels and large covered areas that are intended to be Y NA
illuminated both day and night. O
§130.3(a)3. Demand Responsive Electronic Message Center Control. An Electronic Message Center (EMC)
having a new connected lighting power load greater than 1S kW has a control installed that is capable of Y N N/A
4 reducing the lighting power by a minimum of 30% when receiving a demand response signal. O O
EXCEPTION to Section 130.3(a)3: Lighting for EMCs that is not permitted by a health or life safety statute, Y NA
ordinance, or regulation to be reduced by 30%. O
Field Inspector Notes:
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
STATE OF CALIFORNIA
SIGN L,IGHTING-
CEC-NRCC-LTS-01-E(Revised 08/16)
CERTIFICATE OF COMPLIANCE
Sign Lighting
Proiect Name:
Fa
Date
IA
OMISSION
N RCC-LTS-01-E
(Page 3 of 5)
2. Mandatory Sign Lighting Measures
I have responsibility for installing the sign lighting
❑ Yes, I have responsibility for the sign lighting, and will complete ❑ No, I do not have responsibility for installing the sign lighting. Someone
parts 2a and 2b of this compliance document else will complete parts 2a and 2b of this corn pliance document.
2a. Maximum Allowed Lighting Power Method of Compliance
Certificate of Compliance and Field Inspection Energy Checklist.
Complete this part if there are signs using the maximum allowed lighting power method of compliance. @Complete part 2b of this
Certificate of Compliance if there are signs using the Specific Lighting Sources method of compliance).
A B C D E F G H I
OPTIONAL —
Symbol or Energy Verified Field
Code
Description of the Sign Label (see Allotted Watts Design Complies Inspector
instructions Watt,_ Y/N Check that
below) Sign Complies
o v t
a V1
>. M J \ H =
v C
Q M c E 3 r4 m obi x
y N
SP N X O H II p ;a M n
in c w— Q �. w Q F 5 3 E
O
U
DEl° i ❑
❑ 0
D 0 I ❑
❑ I D
0 ❑
❑ 0 ❑
° ° ❑
❑
❑ o ❑
❑ 0 ❑
A Symbol or code used on the plans (when plans are required) and other documents.
B A description of the sign, or location of sign on the building; and the location of sign on construction documents.
OPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory -installed, ENERGYVERIFIED label, confirming that
the sign complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the (Maximum Allowed Lighting
Power method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks
C authorized by Underwriters Laboratories (UL) or other Product Certification Body accredited to ISO/hEC Guide 65 by the American
National Standards Institute in accordance with ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an
ongoing annual inspection program carried out by a Type A Inspection body in accordance with ISO/ EC 17020. For signs with such
an ENERGY VERIFIED label, columns 'D' through 'I' are not required to be filled out. Note: Using an ENERGY VERIFIED label is an
optional method to validate compliance. An ENERGY VERIFIED label is not needed for compliance.
D The sign area in square feet.
E List "I" if the sign is internally illuminated. List "E" if the sign is externally illuminated.
F Allowed watts per square foot. Enter 12 if the sign is listed as "I" in column E. Enter 2.3 if sign is listed as "E" in column E.
G Multiply the square footage in column D times the allowed Lighting Power Density (LPD = watts) in column F.
H Show the total installed watts in the sign, as determined according to the applicable provisions of §130(c).
I Enter Y if the number in column H is less than or equal to the number in column G. Otherwise, the sign does not comply.
1 This page doubles as a field inspection checklist.
Field Inspector Notes:
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
STATE OF CALIFORNIA
SIGN LIGHTING'
CEC-NRCC-LTS-01-E(Revised 08/16)
CERTIFICATE OF COMPLIANCE
Sign Lighting
Project Name:
S
NMISSION
NRCC-LTS-OS-E
(Page 4 of 5)
oate prepareo:
i -11')
)hl'. iJV W
2b. Specific Lighting Source Method of Compliance
Certificate of Compliance and Field Inspection Energy Checklist
Complete this part if there are signs using the Specific Lighting Source method of compliance. (Complete oart 2 of this Certificate of
Compliance if there are signs using the maximum allowed lighting power method of compliance)
A
B
C
D
E
Symbol
or
Code
Description
OPTIONAL
ENERGY
VERIFIED
label
(see
instructions
below)
Specific light source u.;ed for
compliance
Shall include only lig.-lting
technologies listed below
(List all that appl-)
Field Inspector
Check that Sign
Complies
❑
❑
❑
❑
Symbol or code used on the plans (when plans are required) and other documents. ❑
A narrative description of the sign, or location of sign on the building; and the location of sign on construction documents
OPTIONAL - Check this box only if this sign has a permanent, pre-printed, factory -installed ENERGY VERIFIED label, confirming that this sign
complies with the Section 140.8 of the California 2016 Title 24, Part 6 Standards, using the Specific Lighting source Method of Compliance.
The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratories
(UL) or other Product Certification Body accredited to ISO/IEC Guide 65 by the American National Standards Institute in accordance with
ISO/IEC 17011. Surveillance by the Accredited Certification Body shall be an ongoing annual inspection prog-am carried out by a Type A
Inspection body in accordance with ISO/IEC 17020. For signs with such an ENERGY VERIFIED label, column TV is not required to be filled
out. Note: Using an ENERGY VERIFIED label is an optional method to validate compliance. An ENERGY VERIFaED label is not needed for
compliance.
Specific Light Source Compliance Method. The sign(s) identified above use only the following lighting techn:)Iogies:
List all applicable numbers 11 through 9) that apply in column D above for each row.
1 High pressure sodium lamps
Metal halide lamps that are pulse start or ceramic served by a ballast that has a minimum eftbciency of 88% or greater.
2 Ballast efficiency is the measured output wattage to the lamp divided by the measured operating input wattage when
tested according to ANSI C82.6-2005.
Metal halide lamps that are pulse start that are 320 watts or smaller, are not 250 watt or 17� watt lamps, and are
3 served by a ballast that has a minimum efficiency of 80%.
Ballast efficiency is the measured output wattage to the lamp divided by the measured opening input wattage when
tested according to ANSI C82.6-2005.
Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a minimum efficiency of 75% when
4 the transformer or power supply rated output current is less than 50 mA. The ratio of the output wattage to the input wattage is at
100% tubing load.
Neon or cold cathode lamps with transformer or power supply efficiency greater than or equal to a min mum efficiency of 68% when
5 the transformer or power supply rated output current is 50 mA or greater. The ratio of the output wattage to the input wattage is at
100% tubing load.
6 Fluorescent lighting systems meeting one of the following requirements: A.) Use only lamps with a minimum color rendering index
(CRI) of 80; or B.) Use only electronic ballasts with a fundamental output frequency not less than 20 kHz:
7 Light emitting diodes (LEDs) with a power supply having an efficiency of 80% or greater.
Single voltage external power supplies that are designed to convert 120 volt AC input into lower voltage DC or AC output, and have a
8 nameplate output power less than or equal to 250 watts, shall comply with the applicable requirementsof the Appliance Efficiency
Regulations (Title 20).
9 1 Compact fluorescent lamps that do not contain a medium screw base sockets (E24/E26).
E This page doubles as a field inspection checklist
Field Inspector Notes.
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
STATE OF CALIFORNIA
SIGN LIGHTING.,
J
- EC-NRCC-LTS-01-E Revised 08/16 CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE
Sign Lighting NRCC-LTS-01-E
Project Name: (Page 5 of 5)
A • �) /�A` L n Date Prepared: �. •
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Company:
Signature Date:
Address:
y� 9ys
q �� �� yG CEA Certification Identification (if applicablel:
C7 n_ J—(
City/State/Zip:
Phone: _
RESPONSIBLE PERSON'S DECLARATION ST EMENT
I certify the following under penalty of )erjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified
on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency for approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this
Certificate of Compliance is required to be included with the documentation the builder provides to the • uilding owner at occupancy,
Responsible Designer Name:
Lt- � / !c Responsible Designer Signature:
Company: n �M
Date Signed: l
Address: l� J v _—'
c�� __r ''3a l �`�1� License:
City/State/Zip: rte/ c/LeJ
` Phone: 7
4t/�
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance
August 2016
85"
White Acrylic
letters w/ brushed
vinyl Faces
-
13.3 "
30"
. Day night vinyl
faces
COW
7„
White Acrylic Black returns Black Trim
letters w/ brushed
vinyl Faces
ig arama
The way to grow your business.
41945 BOARDWALK, SUITE L
PALM DESERT, CA 92211
PH 760.776.9907 / FX 760.776.9844
Frontage: _25_ Linear Feet
Total Signage _17.7_ S.F.
Contractor's Lic # 830131 C45, C61/D42
Workers Comp. # 1938807
City LIC. #97005491
Customer:
Infinity Hair Design
Address:
78-347 Hwy 111
La Quinta, CA 92253
Acrylic Faced Channel Letters
Depth: 3.5"
Aluminum Thickness: .040
Acrylic Thickness: 1/8"
Face Color: White Acrylic w/
Brushed vinyl faces
Day night vinyl
Return Color: Black
Trim Cap Color: Black
Mounting: Back
Standoff: Flush
L.E.D. Color: White
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CO STRUCTION
DAT/�— sy—J11V�
Telephone: 760-564-34441 Jobsite:
Fax: 760-xxx-xxxx I Same
Dwg. No.: 87861
Date: 11-30-17
Designer: GA
Salesperson: BS
North ELEVATION
Rev.. 1
CHANNEL LETTER & LIGHT BOX SECTION 3,5",040 ALUMINUM
INTERNALLY ILLUMINATED L.E.D. RETURNS
WALL �— TRIMCAP
ACRYLIC FACES
HOUSE
POWER—*J�,L.E.D.
MODULE
LOW VOLTAGE WIRE
DISCONNECTWIRE NUTS
SWITCH
CH LETTER FASTENED BY A
IMUM OF 4 #10 SCREWS
H STUCCO APPROVED
HORS
12VOLT L.E.D,
DRIVER SHEET METAL SCREW
ALL WALL PENETRATIONS TO BE SEALED WITH UL LISTED I SILICONE SEALANT
U.L. 48
NEC ELECTRICAL CODE 2014
THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH REQUIREMEN I S OF
ARTICLE 600 ON THE NATIONAL ELECTRIC CODE AND OR OTHER APPLICABLE LOCAL CODES.
THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
CHANNEL LETTER CONNECTION DETAIL
12VOLT L.E.D. DISCONNECTSWITCH ►
DRIVER_HOUSE POWER
MOUNTING STUCTURE
auuae. cwlrra cww�a
U1. LISTED AND LABELED
COMPLIES WITH 2016 CA ELECTRIC CODE, ARTICLE 600
Customer Approval:
Landlord Approval:
YOUR SIGNATURE ACKNOWLEDGES FULL APPROVAL OF DESIGN CONTENT
AND LAYOUT, RELEASING SIGN A*RAMA FROM RESPONSIBILITY IN REGARD
TO INCORRECT DESIGN AND INFORMATION. THE COLORS SHOWN ARE ONLY
REPRESENTATIVE OF ACTUAL PMS COLOR CALL OUTS, FINAL COLOR WILL
BE MATCHED AS CLOSE AS POSSIBLE, COMMENSURATE WITH MATERIALS USED.
THIS DESIGN IS PROPRIETARY PROPERTY AND MAY NOT BE USED WITHOUT
THE EXPRESSED WRITTEN CONSENT OF SIGN*A*RAMA.
Al