BMCH2017-026378-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
c&t�t 44�Qum&
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number: BMCH2O17-0263
Property Address: 79140 BIG HORN TRAIL
APN: 776030017
Application Description: LOCKHART/ CHANGE OU 1 16SEER/81AFUE SPLIT SYSTEM
Property Zoning:
. Application Valuation: $11,500.00
Applicant:
IE INC JUN 2 6 2017
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362 CITY OF LA QUjNTA
DESIGN AND DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C20 License No.: 763937
Date: i Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
'compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
( ) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
( ) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153.
Date: 6/26/2017
Owner:
ROBERTLOCKHART
, 92253
Contractor:
VOTTA ENTERPRISES INC DBA COMFORT -AIR
72248 NORTHSHORE ST STE 101
THOUSAND PALMS, CA 92276
(760)320-5800
Llc. No.: 763937
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I' have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the'Labor Code, for the performance
of work for which this permit is issued.
. I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WSD5034539
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Z i Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-rmentioned property for inspection purposes.
b `
Date: ziO 11 Signature (Applicant or Agent): ��
Date: 6/26/2017
Application Number: BMCH2017-0263 Owner:
Property Address: 79140 BIG HORN TRAIL ROBERT LOCKHART
APN: 776030017
Application Description: LOCKHART/ CHANGE OUT (1)16SEER/81AFUE SPLIT SYSTEM 92253
Property Zoning:
Application Valuation: $11,500.00
Applicant: Contractor:
IE INC VOTTA ENTERPRISES INC DBA COMFORT AIR
31225 LA BAYA 72248 NORTHSHORE ST STE 101
WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276.
(760)320-5800
Llc. No.: 763937
-----------------------------------------------------=---------------------------------------
Detail: HVAC CHANGE OUT - 16SEER/83AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016
CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT-SYSTEM
101-0000-42402
0
$76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT-SYSTEM PC
101-0000-42600
0
$38.00
Total Paid for CHANGEOUT: $114.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$96.27
Total Paid for PERMIT ISSUANCE: $96.27
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
Bin.#
C►ty of La Quina
-Building 8t Safety Aivision
P.O. Box 1504,78-495 Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
3 Building Permit Application and Tracking Sheet
Permit #
j1
Project Address: 79140 Big.Horn Trail
Owner's Name: Bob Lockhart
A. P. Number.
Address: 79140 Big Horn Trail
Legal Description:
City, ST, Zip: La Quinta, CA' 92253
Contractor. Comfort Air
�t C �5tiE. ffO�v:S' ;
Telephone: 2064aa: .
Address: 72248 Northshore Street Suite 101
Project Description: Replace 5 ton A/C in side yard, coil, & .
City, ST, Zip: Thousand Palms, CA 92276
90,000 BTU furnace in garage
Telephone: 760-320-5800
\1�i.. .`
f �:"C`''
•.:'
City Lic #;
State Lic. # 763937
Arch., Engr., Designer.
Address:
City., ST, Zip:
Telephone:v .Y `� �.
State LIC. #:.��.., sS�, �.
,„:wsru . ,r
Construction Type:. Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Sq. Ft.: #Stories: #Units:
Name of Contact Person: Steven Schnierer
Telephone # of Contact Person: 818-73577876
Estimated Value of Project: $11,500.00 .
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACENG
PERMIT FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Cale$.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Cates.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Gi-ading plan
2' Review, ready for correctionstiissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'^` Review; ready for corrections issue .
Developer Impact Fee
Planning Approval.
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit Issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC)
Project Name:
BOB LOCKHART ( Date Prepared:
CF111-ALT 02-E
(Page 1 of 3)
2017-06-26
A. General Information,
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
BOB LOCKHART
02
Date Prepared
2017-06-26
03
Project Location
79140 BIG HORN TRAIL
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
HOUSE
SC System
SC System
system a
refrigerant
Installing new SCS
07
Zip Code
..
92253 t*�``
1;
{ 08 J
Dwelling Unit Conditioned
;
3400
by this SC
ducted
containing
system
Z
Floor Area (ft)
entirely new
entirely new
E..
/
Number of Space
system?
09
Climate Zone
15 M
X10,
Conditioning (SC) Systems in
1
SYSTEM 1
WHOLE HOUSE
3400
Yes
this Dwelling Unit:
Yes
B. Space Conditioning (SC) System Information rS II }j
01
02
03
04
05it =
N—, 105 Y
07
08
09
10
CFA served
Is the SC
_
Installing a�
SC System
SC System
system a
refrigerant
Installing new SCS
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
SYSTEM 1
WHOLE HOUSE
3400
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 417-A020099775A-000-000-0000000-0000
Registration Date/Time: 2017-06-26 07:01:32
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-26 07:01:32
CERTIFICATE OF COMPLIANCE CF111-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
. Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central gas
All new
Central split
All new
This field or
This field or
SYSTEM 1
furnace
heating
AFUE
0.81
AC
cooling
SEER
16
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
-Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums R6 (CZ 1� 10 12 ands 13) and Rg (CZ 11 and 14-16)
CF2R and CBR -MCH -20-H - Duct Leakage Test required when heating or cooling components are.'installed in dycted systems, or when more than,40 ft of duct length is replaced
-Leakage rate compliance: <=15% or <= 10% leakage to outside, or seal all accessible leaks.� ,f f
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing cc�m ponents are ins Iled or altered (applicable in CZ 2, 8-15).
CM and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required �. �,�: "
Exceptions: "''?
Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Lea6jg jesting requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MCH -25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
�. i W-11 t � i, I;( I " �4 . I *_J
E. Entirely New or Complete Replacement Duct System, with or withput'Equlpment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not appl yto this�p o ect.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 417-A020099775A-000-000-0000000-0000
Registration Date/Time: 2017-06-26 07:01:32
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-26 07:01:32
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Patty Hernandez
Patty Hewn,a nt
Company:
Signature Date:
Votta Enterprises, Inc. dba Comfort Air
2017-06-26
Address:
CEA/ HERS Certification Identification (if applicable):
72248 Northshore Street #101
City/State/Zip: }
Phone:
Thousand Palms CA 92276 r .- �`
760 3Z0-5800
Responsible Person's Declaration statement r `aC psi
I certify the following under penalty of perjury, under the laws of the State of California: �{ '
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform.to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency}for approval;with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance'sha�ll a madetavailablle with thd-building permits) sued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is=required-to be included with&the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Tracy Garza �1��� �i��
Responsible
" }f
y
Company:
Date Signed:
Votta Enterprises, Inc. dba Comfort Air
2017-06-26
Address:
License:
72248 Northshore Street #101
763937
City/State/Zip:
Phone:
Thousand Palms CA 92276
760-320-5800
Digitally signed by CHEERS". This digital signature is provided in order to secure the content of this registered
document and in no way implies Registration Provider responsibility. for the accuracy of the information.
Registration Number: 417-A020099775A-000-000-0000000-0000
Registration Date/Time: 2017-06-26 07:01:32
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-06-26 07:01:32