Loading...
BMCH2015-036978-495 CALLE TAMPICO D. D aw VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 CO UNITY D ELO DEPARTMENT - - D INSPECTIONS (760) 777-7153 BUI IN IT Date: 9/29/2015 Application Number: BMCH2O15-0369 SEP 2 9 2015 Owner: Property Address: 79886 INDEPEND NCE Y DOUGLAS GEE APN: 604501025 79886 INDEPENDENCE WY Application Description: GEE RESIDENCE / VAC CHANabof LA QUINTA LA QUINTA, CA 92253 Property zoning: COMMUNITY DEVELOPMENT DEPARTMENT Application Valuation: $8,000.00 l Applicant: Contractor: ALL DAY HEATING & COOLING ALL DAY HEATINC & COOLING 82578 PISA CT 82578 PISA CT INDIO, CA 92203 INDIO, CA 92203 (760)834-1064 Llc. No.: 954337 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 954337 Date: Ilk at// 5 'Contractor: - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( 11, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSAT ON DECLARATION I hereby affirm under penalty of perjury one ot'the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 370C of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurana2 carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of -he work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3 700 of the L or Code, I shall forthwith comply with those provisions. Date: Z°C I S Applicant: WARNING: FAILURE TO SECURE WORKERS' COM PENSATIO COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMI"'%L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1.Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is perform �d under or pursuant to any permit issued as a result of this application , the ownea, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to tme work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applic: tion becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws rel ting to tluilding construction, and hereby authorize representavives of this city o enter pon e above-mentioned property for inspection purposes. Date: ti� L� Signature (Applicant or Agen i. Description: GEE RESIDENCE /HVAC CHANGE OUT Type: MECHANICAL Subtype: Status: APPROVED Applied: 9/29/2015 MFA Parcel No: 604501025 Site Address: 79886 INDEPENDENCE WAY LA QUINTA,CA 92253 Approved: 9/29/2015 MFA Subdivision: TR 24197-3 Block: Lot: 6 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $8,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites -_0 Details: HVAC CHANGE OUT -15 SEER/80AFUE SPLIT SYSTEM [2008 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. Applied to Approved ADDITIONAL Printed: Tuesday, September 29, 2015 9:56:59 AM 1 of 2 r SYS7EAAS INSPECTIONS PARENT PROJECTS ............ . BOND INFORMATION ATTACHMENTS Printed: Tuesday, September 29, 2015 9:56:59 AM 2 of 2 SYSTEMS --- CLTD DESCRIPTION ' ACCOUNT _. QTY AMOUNT• PAID a PAID DATE RECEIPT # CHECK # _ METHOD PAID SY BY HVAC CHANGEOUT - 101-0000-42402 0 $72.52 $0.00 SPLIT -SYSTEM HVAC CHANGEOUT - 101-0000-42600 0 $36.26 $0.00 SPLIT -SYSTEM PC Total Paid for CHANGEOUT: $108.78 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• 00 INSPECTIONS PARENT PROJECTS ............ . BOND INFORMATION ATTACHMENTS Printed: Tuesday, September 29, 2015 9:56:59 AM 2 of 2 SYSTEMS CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-1R-ALT- Project-Name: F-1R-ALT• Project Name: 79-886 Independence Way I Date Prepared: CF1R-ALT-02-E (Page 1 of 3 ) 2015-09-29 A. General Information MR -ALT -02 is applicable to multiple space conditioning system contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT 02 document for each dwelling unit. 02 01 Project Name 79-886 Independence Way 06 02 Date Prepared 2015-09-29 03 Project Location 79-886 Independence Way 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 79-886 Independence Way 07 Zip Code I 92253 08 Dwelling Unit Conditioned 1950 SC System ; CFA served Floor Area (ft2) refrigerant ` ;Installing new":SC- Install�in`g l I = RInstalling Number of space conditioning Identification or 09 Climate Zone 15 10 (SC) systems in this dwelling 1 entirely new entirely new Name unit. System (ft2) fit B. Space Conditioning (SC) System Information 01 02 03� 04;� II ;05 06 ' ° 07" q 08 09 10 § Is the SC`s Installing a b { •- � o a SC System SC System CFA served system a refrigerant ` ;Installing new":SC- Install�in`g l installing = RInstalling Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 whole home 1950 Yes Yes Yes No. No No Altered space conditioning system k Registration Number: 215-A6340718A-000000000-0000 Registration Date/Time: 2015-09-29 07:01:43 CA Building Energy Efficiency Standards - 2013 Residential Compliance i Report Version: 2013-1.006 HERS Provider: CaICERTS Report Generated: 2015-09-29 07:01:46 CERTIFICATE OF COMPLIANCE I CF1R-ALT-02-E i Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 ). D. Altered Space Conditioning System (Sections 150.2(b)1E andl F) O1 02 03 04 05 ( 06 07 08 09 10 11 12 Heating . Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value i System Type Components Type Value Type Duct Length R -Value Central gas All new I 1 Central split All new Less than or System 1 furnace heating AFUE 80 AC cooling SEER 15 Setback equal to 40 R-8 components components feet Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF311-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: 515%, ors 10% leakage to outside, or seal all accessible leaks l CF211-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow z 300 CFM/ton required when MCH -25 is required. Exceptions: I1' -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage sting requirements. b , -Heating-only systems and Air Handler/Furnace changes do not require verification of AIrFlow MCH 23 or r&i erarit Charge MECH 25., } f -Existing duct systems constructed, insulated or sealed with asbestos are exemptifrom MCH=20 Duct Leakage Testing IF _regui�emerits. r ,� ,��-$ �:.....o:.,l .;�- � r.,: �:•.,:.., c.:s,.,... _. :{.. -.,. fir....,..-� 'y .-. -:�::.w .k-, E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(ib)iDiia-and 150.2(b)1E, F) This section does not apply to this project. I F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) Thisisection does not apply to this project. Registration Number: 215-A6340718A-000000000-0000 Registration Date/Time: 2015-09-29.07:01:43 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013-1.006 Report Generated: 2015-09-29 07:01:46 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -1R -AL CF111-ALT-02-E (Page 3 of 3 ) Documentation Author's Declaration Statement i. 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: SANCHEZ, MIGUEL I I' r '�"�►> Company: ( Signature Date: MIGUEL SANCHEZ 2015-09-29 07:01:43 Address: CEA/ HERS Certification Identification (if applicable): 83947 Moonlit Drive City/State/Zip: Phone: Coachella CA 92236 760-834-1064 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: I 1. The information provided on this Certificate.of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept 6sponsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). I 3. That the energy features and performance specifications, materials, components and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of ItegulatioI O. i l — 4. The building design features or system design features identified ori this Certificate of Compliance are consistent with,the information provided ori other applicabl ompliance documents, worksheets, ss 1 y.,r rr.t,; g -x a calculations, plans and specifications submitted to the enforcement:agency for, approval;with this building permit application. f : S. I will ensure that a registered copy of this Certificate of Compliance shill-be.made.available'with'the building permit(s).issued for the.I wilding, and,ma4' available to_the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compinancexis,required to be,included with the,documentation,the builder provides to the building owner at occupancy. Responsible Designer Name: f '� � �-�^ ResponSlble Designer Signature: SANCHEZ, MIGUEL C Company: Date Signed: MIGUEL SANCHEZ 2015-09-29 07:01:43 Address: License: 83947 Moonlit Drive ! 954337 City/State/Zip: Phone: Coachella CA 92236 i 760-834-1064 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure I the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A634071SA-000000000-0000 Registration Date/Time: 2015-09-29 07:01:43 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance I Report Version: 2013-1.006 Report Generated: 2015-09-29 07:01:46 Bin #city of La Quinta Building 8t• Safety Division Permit #{ 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-70.12 Building Permit Application and Tracking Sheet Project Address q—$g(. Owner's Name:,Dv--) A. P. Number: Address: q_� v� c ,loc ` e-.�•.a Legal Description: City, ST, Zip: �, ZZ� ntra Co ct r o. c o •.b � o 3 T elePhone: Wm. WN Address: �J Project Description: City, ST, Zip: 1 �-z'� v q a -a-03 lLc c�oz �G A• �L Cb*eC7�%•o TeleP he: o a7 O J State Lie. # City Lie. #.- ;Arch., Arch.,Engr., Designer: Address: City, ST, Zip: Telephone: � n cti Co stru on Type: Occupancy: P y. State #• Lie. r Demo Project tYPa (circle one • New Add' Repair Name of Contact Person: , S."•.� G Sq. Ft.:hetj # Stories: #Units: Telephone # of Contact Pers n: ^� 6� 3`{_ t tJ Estimated Value of Project: t oat • '' APPLICANT: DO NOT WRITE BELOW THIS LINE t! Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Depos.a Truss Cates. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan . Plans resubmitted Mechanical ' Grading plan 2"' Review, ready for-corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for correctionstissue Developer Impact Fee, Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue 'School Fees, Total Permit Fees ^C—