Loading...
BRER2017-015078-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2017-0150 Property Address: 81443 JACARANDA CT APN: 764780065 Application Description: FUSICK / 291 SF CASITA ADDITION Property Zoning: ����__ Application Valuation: $46,000.00 III II /�\ n � i Applicant: AUG 2 2 2017 OIC DAZ _ I f P 0 BOX 5083 CITYOFLE OUIN7A LA QUINTA, CA 92253 COMMUNITYp�ELOPMENTDEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and .my License is in full force and effect. License Class B License No.: 944325 ti Co�ntrecfor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's VOICE (760) 777-712 FAX (760) 777-701 INSPECTIONS (760) 777-715 Date: 8/22/201 Owner: FUSICK INV INC 407 SMC ITHSTONE CRES SASKATC ON SK CANADA S7J, T1 92253 ContractDr: DAZ P 0 BOX 5083 LA QUINTA, CA 92253 (760)285-3793 Llc. No.: 944325 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Sec_ion 3700 of the Labor Code, for the performance X_ k for which this permit is is sued. = have and will maintain wcrkers' compensation insurance, as required by io 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE COMPENSATION INSU RANCE FUND Policy Number: 9168769 _ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3AofaborCode, I shall forthwith comply Iw,ithh those provisions. Da t/ p %Z ppl�:- WARNING: FAILURE TO SECURE WOR' ERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ;$ 100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROV"DED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set for•.h on this application. 1. Each person upon whose behalf tiis application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issuec as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless :he City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of tiis application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation.of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this cit ter upon the above- mentioned pr p ty f�r inspection purposes. " Date:-' nature (Applicant or Agent): Date: 8/22/2O1-1 Application Number: BRES2017-0150 Owner: Property Address: 81443 JACARANDA CT FUSICK INV INC ' APN: •764780065 407 SMOOTHSTONE CRES Application Description: FUSICK / 291 SF CASITA ADDITION SASKATOON SK CANADA S7J, TS 92253 Property Zoning: Application Valuation: $46,000.00 Applicant: Contracr:or: DAZ DAZ P 0 BOX 5083 P 0 BOX 5083 LA QUINTA, CA 92253 LA QUINTA, CA 92253 (760)285-3793 --------------- ---------------------------------- Llc. No.: 944325' ----------------- Detail: 291 S.F. ATTACHED ------------------------- CASITA ADDITION W/ ENTRY PORTICO (CONVENTIONAL LIGHT -FRAME CONSTRUCTION). THIS PERMIT DOES NOT INCLUDE BLOCK WALLS OR ALTERATION TO OTHER PORTIONS OF THE HOME. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $65.36 DESCRIPTION ACCOUNT QTY AMOUNT .ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000=426000 $179.36 Total Paid for ADDITION: $390.64 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-000042600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0. $5.07 Total.Paid for MECHANICAL: $144.40 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401. 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $17.73 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $50.68 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000=42401 0 $12.67 DESCRIPTION ACCOUNTQTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $169.76 DESCRIPTION ACCOUNT QTY AMOUNT SMI -RESIDENTIAL 101-0000-20308 0 $5.98 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $5.98 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHAMCEMENT FEE: $5.00 •, Bill • Permit #. Pro"ItAddrlsl.�/ Qty of La Quht to Buildina 8i• Safety Division - 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet Owner's Name:�—A. 0 Me i Address: L' � q Legal Description: City, ST, Zip: • Contractor: �i Telephone: Address:A4City g 3. Project Description: City, ST, �—d--�2�-1 Telephone: P 0 State State Lic. # : /tj'y Lic. 9.- kINf1WW0 Arch., Engr., Designer: ViNino vi Hca UID Address: -V2IM 6 9 Nnr. City, ST, Zip: Telephone- - Construction T u Y P e: roJe t hP e (circle one): N w ter Repair Demo ,- State te Lic-# - Name of Contact Person:Sq. A&V Ft.: (. #Stories: #Units: Telephone # of Contact Person: Estimated Value of Project: vv 40 APPLICANT: DO NOT WRITE BELOW THIS LINE zY Submittal Rcq'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Chdck submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Pcrson Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrcctions/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. Ii.O.A. Approval Plans resubmitted Grading IN HOUSE:- 'rd Review, ready for corrcctions/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. APPr Date of permit issue School Fees, Total Permit Fees Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA:.. - AMOUNT .. LEVEL ONE AMOUNT: - LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: . DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: rilogy Date: July 12, 2017 Owner's Name: Fusick Inv. Inc. Phone No. 760-285-3793 Project Address: 81-443 Jacaranda Ct. Project Description: Addition Attached Casita APN: 764780065 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 291 sq. ft. Certification of Applicant/Owners: The person signing certifie that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorize t i n on behalf of the owner/developer. Dated: July 12, 2017 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THEA OVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note• Number of Sq.Ft. 291 Amount per Sq.Ft. $0.00 Amount Collected $0.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director. of Facilities and Maintenance Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: zQ. A2 . W `-d NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 308 t, effective January 1, 1997, requires that this District provide (1) a written notice to. the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -da r to rote im 8shh 1 of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and othe e la ' of I's ve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payme erf r nf n Cher requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set fortha,whether pays a at this - time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined � e t h of District, and up to three (3) such extensions may be granted. AU M7 MV:c/Inydoes/devt'ees/certificate of compliance form updated 3-2007 11/2010 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Trilogy at La Quinta 60-750 Trilogy Pkwy La Quinta, CA 92253 Ph: 760-777-6059 Fax: 760-777-1620 June 27, 2017 Fusick Inv Inc 407 Smoothstone Cres Saskatoon SK Canada S714TI CAN RE: Design Review Modification Conditionally Approved 81443 Jacaranda Ct / Customer ID #: TRLAQ-1032-01 Dear Fusick Inv Inc: We are pleased to inform you that your plans for installation of a casita and front yard re -landscaping, received on June 22, 2017, have been approved by the Design Review Committee with the following conditions: 1, 3, 7, 17, 19 and 20. -Barrel Cactus t not.approved for the frontyards,'the Olive`tree must be fruitless the Melaleuca tree isnot on the approved plant list. Weed.barrier shmild hA iniztane,� �., „►�.,*..,,,:�.,,,, .:,..,t..�� ��,__.:__ Ci This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build on any property other than that 'of the;:appli,cant This approval is related solely to the items reserved for approval by the CC&R's in accordance with the` Design Review Guidelines. The approval does not extend to the quality of work done:'by.your architect, or contractor; or tq.any structural engineering, soils engineering, or site grading and drainage,desgn. You are urged.to obtain_theservices:of a state licensed professional for consultation as needed. The Design Review Committee is composed of volunteers. As such, it does not review applications to ensure compliance with building codes, or other local or state laws. Please be advised that this approval does not relieve you from obtaining any necessary building permits from the Bove- mmentalagencies involved to ensure compliance with these codes. Any violations of these ordinanceswill be your responsibility to correct. Thank you for your patience in this matter and for complying with the Association'spolicies an_d;standards. Sincerely, For the Design Review Committee, M irna Aceves Landscape/DRC Specialist Enclosures cc: Board of Directors Design Review Committee Pian Submittal Bullding PenNt Number. BRES 2017-0150 Project Descripiloir attach sectio Exempt: O (Materials may umrdai n hazardous wastes and are not in"act to recycling provision) Construction Debris Management Plan Number, Sbaet, or PO eco CRY, State, Postal Code Owner's Phone Number Owners E -Mau Address Project Managers Project Matte Phone N Pf0J ! a Buldder/ Conor Number, Street or PO City, State, Postal C Biebl aIuare City Approval By Date of City Approval To Be Discarde Product Trash Asphalt Brlck/Block Cardboard Commingled Concrete Drywall Donsted / Reuse* *Describe Items 7/1912017 81443 Jac manda Ct Andy Fusick 81443 Jacaranda Ct La Quinta, CA. 92253 WA Alberto Daze 760-2853793 DAZ Const P.O. Box 5083 La Qulnbk CA. 92248 Approx 291 square feet RECEIVED AUG 0 2 2017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Tons Not recyclable Recyclable Recyclable Recyclable Reayclabbl Reg,clabbl Recyclable Product Masonry (broken) Plaster Scrap Metal T le (floor) The (roof) Wood Landscape Debris Tons O.0 0.2 O.0 O.0 O.0 0.4 O.0 125 0.00 0.00 0.00 0.00 1.Recyclable !0-(,Ju Totals: Rewcle Trash 2.4 1 1.3 Projected Diversion: 65.28°X, I understand it is the property owners responaa tlitiy to submit copres of weight tickets or receipts to the Dis trld Ernthmnental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named protect shall guarantee that at least 6596 of the jobsRe waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recyoing or reuse, remaining materials generated from the first day of the project through the completion of the project In accordance with this plan. This DMP Is issued in the name of the property owners) and shall remain their properly throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP Is still Issued in the name of the property owner(s) and the owner retains legal responsill ft for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general conbactor shall be kept Informed of the diversion progress through bk m ft reports. ff saif-hauMg, all refuse material from this project site must be tabun to an approved recycler or t wmW Owner) Developer) Project Manager / Superintendent Data CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD PrViect Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribdl6x CF1R-PRF-01 Page 1 of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Single Family Residence 106.1', tri•r:,�fi 'Z. ,WLr-c ,., -;.A 1,06. �riF 07 02 Calculation Description Title 24 Analysis Standard Design Proposed Design Compliance Margin 03 Project Location 81443 Jacaranda Court 0.03 1.26 -1.23 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.1 10 Building Type Single FamilyFront ---- 0.00 Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructe 302.45 302.22 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 291 Number of Zones 1 16 Slab Area (ft2) 291 'Jp& Number of Stories 1 18 20 Addition Cond. Floor Area n/a Addition Slab Area (ft2) n/a I Natural Gas Available Yes Glazing Percentage (%) 22.2% COMPLIANCE RESULTS r `" 0 01 Building Complies with Computer Performance 02 This building Incorporates features that require fie nor verification by a certified HERS rater under the supervision of a CECapproved HERS provider. - 03- This building -Incorporates one or more Special Features shown below rr " 1i�—i6 1"7—, 1 F --t "J", (C Registration Number: PRF17-00229211 Registration DateRme: 07/12/2017 12:15 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 AUG U 22017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT HERS Provider: CHEERS Report Generated at: 2017-07-12 11:59:2 ENERGY USE SUMMARY 04 106.1', tri•r:,�fi 'Z. ,WLr-c ,., -;.A 1,06. �riF 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.03 1.26 -1.23 -4100.0% Space Cooling 257.79 257.56 0.23 0.1% IAQ Ventilation 5.20 5.20 0.00 0.0% Water Heating 39.43 38.20 1.23 3.1% Photovoltaic Offset ---- 0.00 0.00---- Compliance Energy Total 302.45 302.22 0.23 6 Registration Number: PRF17-00229211 Registration DateRme: 07/12/2017 12:15 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 AUG U 22017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT HERS Provider: CHEERS Report Generated at: 2017-07-12 11:59:2 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribdl6x CFI R -PRF -01 Page 2 of 8 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC). A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" Its TDV energy. Because EDR Includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), It is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building Is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Design EDR of Proposed Design EDR Value of Proposed PV Final EDR of Proposed Design 63.6 163.5 0.0 63.5 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on-site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. REQUIRED SPECIAL FEATURES +� The following are features that must be installed as condition for meeting the modeled energy,performance for this computer analysis. • Cool roof `. • Window overhangs and/or fins HERS FEATURE SUMMARY ..•r.: n n r -z .-- �-�. .rte The following is a summary of the features that must be field -verified by a "certified HERS Rater as a,00ndition�for`meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: UfkCt"atched & trvi1e Wi' h htev_6t�,r • IAQ mechanical ventilation -� Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • . Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: PRF17700229211 Registration Date/Time: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribd16x CF1R-PRF-01 Page 3 of 8 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 291 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Housel 291 9 DHW Sys 1 Gross Area (ft2) OPAQUE SURFACES 01 02 t� _03,'`•;`• t - l� 04 05 06 07 08 Name Zone Construction '. s Azimuth Orientation Gross Area (ft2) Window 8 Door Area (ft2) Tilt (deg) Front Wall Whole House R-15 Wall w/1 EPS 7 0 Front 500 20 90 Left Wall Whole House R-15 Wall w/1 EPS/ 270 Right 140 12.5 90 Rear Wall Whole House R-15 Wall w/1.EPS 180 Back 500 8 90 Right Wall Whole House R-15 Wall w/1 EPS 90 Left 140 24 90 Roof Whole House t C R-38 Roof r -, r .� ,. 291 ATTIC 01 02 x`03 # 1U'L4 )k0j vt' vc..:u 044-1its °it tty 05 06 07 08 Name Construction Type Roof Rise Roof ReflectanceRoof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House Ventilated 0 0.3 1 0.75 Yes Yes Registration Number: PRF1.7-00229211 Registration Date/Time: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribd16x CFI R -PRF -01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading Window Window Front Wall (Front -0) 2.0 5.0 1 10.0 0.30 0.23 Insect Screen (default) Window 2 Window Front Wall (Front -0) 2.0 5.0 1 1 10.0 0.30 0.23 Insect Screen (default) Window 3 Window Left Wall (Right -270) 2.0 2.0 1 4.0 0.30 0.23 Insect Screen (default) Window 4 Window Left Wall (Right -270) 2.0 2.0 1 4.0 0.30 0.23 Insect Screen (default) Window 5 Window Left Wall (Right -270) 3.0 1.5 1 4.5 0.30 0.23 Insect Screen (default) Window 6 Window Rear Wall (Back -180) 2.0 4.0 1 8.0 0.30 0.23 Insect Screen (default) Window 7 Window Right Wall (Left -90) 3.0 8.0 1 1 24.0 0.30 0.23 Insect Screen (default) OVERHANGS AND FINS r 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent ,Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 i _2 ;.-, 0-, 0 0 0 0 0 0 0 0 Window 4 2 0.1 2' 2 0" 0 0 0 0 0 0 0 0 Window 5 2 0.1 2l..:., . •y �j2 •Tt ,.•,..0, cr- , , !-, 0.,...:± , 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0-1 0 0 0 0 0 Registration Number: PRF17-00229211 Registration Date/Time: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribd16x CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 10 11 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Tank Location or Heater Number Volume • Cavity/Frame: no insul. /2x4 Top Chrd Input R -value Standby Loss I 2x4 Top Chord of Roof Truss @ 24 Ambient Name Roof Deck: Wood Siding/sheathing/decking Attic RoofWhole House Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) NEEA Heat Pump Type Condition DHW Heater 1 Gas Small Instantaneous 1 • Inside Finish: Gypsum Board 0.94 EF 190,000 Btu/hr R-0 n/a n/a /a • Cavity/Frame: R -15/2x4 • Sheathing /Insulation: R4 Sheathing R-15 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.064 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 R-38 Roof attic) Wood Framed Ceiling 2x4 @'1,6 in..,O.C. R 38 0.025 • Over Ceiling Joists: R-28.9 insul. SLAB FLOORS 01 02 03 ! < f 04 05 06 07 Name Zone Area (ft2)` Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House 291 1 35 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 -02, ___ , , 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation'''-: Building Envelope Air Leakage CFM50 Not Required Not Required Not Required --- WATER HEATING SYSTEMS 01 _ 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS 01 _ 02 03 04 05 06 07 08 09 10 11 Tank Energy Tank Insulation Tank Location or Heater Number Volume Factor or Input R -value Standby Loss I Ambient Name Element Type Tank Type of Units (gal) Efficiency Rating/Pilot (Int/Ext) Recovery Eff NEEA Heat Pump Type Condition DHW Heater 1 Gas Small Instantaneous 1 0.1 0.94 EF 190,000 Btu/hr R-0 n/a n/a /a Registration Number: PRF17-00229211 Registration Date/Time: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribd16x CF1 R -PRF -01 Page 6 of 8 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Whole Housel Other Heating and Cooling Syste m Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 ,,.-11 b4 05 06 07 08 Verified Airflow a 4--zVerified , Airflow Target ,:4 _Verified EER Efficiency Refrigerant Charge Cooling Component 1 -hers -cool Required Name System Type Number of Units' r EER-' SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 PkgAirCond 1 _ _12 / 14 Not Zonal Single Speed Cooling Component 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow a 4--zVerified , Airflow Target ,:4 _Verified EER Verified SEER Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers•dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required Required Registration Number: PRF17-00229211 Registration Dateffime: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribdl6x CFI R -PRF -01 Page 7 of 8 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 4 04 05 06 Dwelling Unit IAQ CFM IAQ Watts(CFM! IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 33 i -'0.25 F Default 0 Required ilnwalx tod ervi: v� kh Intagr ty Registration Number: PRF17-00229211 Registration DateRme: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 11:58, Wed, Jul 12, 2017 Calculation Description: Title 24 Analysis Input File Name: Fusick Casita.ribdl6x CFI R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan Hacker Joawftcuke.- Company: Signature Date: Joan Hacker 07/12/2017 Address: CEA/HERS Certification Identification (If applicable): 72875 Fred Waring Drive City/State/Zip: Phone: Palm Desert, CA 92260 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibildy.for,the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.'" 3. The building design features or system design features identified on this Certificate.of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:.. Responsible Designer Signature: Joan Hacker Jocuv�Eacker Company:t Joan HackerC�- -Date Signed: 0-7/12/207 Address: License: e 72875 Fred Waring Drive i1 irnarcbrad Smn--i 1--itearity City/State/Zip: Phone: Palm Desert, CA 92260 760-345-1352 Digitally signed by CHEERSTm. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: PRF17-00229211 Registration Date/Time: 07/12/2017 12:15 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05232017-695 Report Generated at: 2017-07-12 11:59:21