Loading...
BMCH2017-0107rr 78-495 CALLE TAMPICO Twit 4 4 Q" LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BMCH2O17-0107 Property Address: 78800 LIMA ST ST APN: 776080015 Application Description: ZUZACK / HVAC CHANGEOUT 16SEER/82AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $6,000.00 Applicant: ALBERT CLALDE DBA A AND G AIR SERVICES 81891 SANDY COURT INDIO, CA 92201 NE APR 01 2017 -CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 ^ License No.: 743185 Date: 3' ` ( Contractor: t OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply'to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/3/2017 Owner: RONALD ZUZACK Contractor: ALBERT OLALCE DBA A AND G AIR SERVICES 81891 SANDY COURT INDIO, CA 92201 (760)342-010D. Llc. No.: 743185 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificace of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of�jie wor for which this permit is issued. �� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: NORGUARD INSURANCE COMPANY Policy Number: ALWC700545 _ I certify that in the performance of3he work for which this permit is issued, I shall not employ any person in any manner sc as to become subject to the workers' compensation laws of California, and agree tF at, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. 41- ^� Date: S- \71 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on thi: application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and `he applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to tke work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation_ I certify that I have read this application and state, that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representa-:ives of this city to enter upon the above- mentioned property for inspection purposes. Date:—'4'- Signature (Applicant ar Agen f Y Application Number: BMCH2017-0107 Property Address: 78800 LIMA ST ST APN: 776080015 Application Description: ZUZACK / HVAC CHANGEOUT 16SEER/82AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $6,000.00 Applicant: ALBERT OLALDE DBA A AND G AIR SERVICES 81891 SANDY COURT INDIO, CA 92201 Date: 4/3/2017 Owner: RONALD ZUZ<.CK Contractor: ALBERT OLALDE DBA A AND G AIR SERVICES 81891 SANDY COURT INDIO, CA 922101 (760)342-0100 Llc. No.: 743185 -------------------------------------------------------------------------------------------- Detail: HVAC CHANGE OUT - 16SEER/82AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. vd FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $38.00 Total Paid for CHANGEOUT: $114.00 DESCRIPTION ACCOUNT QTY AMOUNT :PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin # Permit ;; Project Address: v J C600 City of L a QUhlta BuifdinD 8z- Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701.2 Building Permit Application and Tracking Sleet Owner's Name: A. P. Number: Address: o fk 0, Legal Description: City, ST, Zip: C, t r V'4�i iv iN � e:Cantra Telephone:hon Address: l gG'� er Project Description: _City, ST,Zip: ^. 0K•5�� Telephone P one: v �O l u r - State Lic. City Lic. #.- Arch., Engr., Designer: Address: City, ST, Zip: Telephone: ..C—?Ae....... n Type: e - Constructiontracti Occupancy: . State Lic- # New Add'n Alter Repairai Project ect tYPe (circle ne • r Demo 'Name of Contact Person:� Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: k--., Estimated Value of Project: �pvO v tl Submittal Req'd APPLICANT: DO NOT WRITE BELOW THIS LINE Rcc'd TRACKING P ZRMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance. Tit!e 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical SubeontactorList Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. M.O.A. Approval Plans resubmitted Grading IN ROUSE:- '"! Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. I'ub. Wks- Appr Date of permit issue School Fees, Total Pcrmit Fees Simplified Prescriptive Certificate of Compliance: 2008 Residential HVAC Alterations CF -1R -ALT -HVAC Climate Zones 10 to 15 Sitr e� Enforcement Agency: Date:t Permit At: CC77 o L. 4 • "7 ^�_i Conditioned Flour Equipment T et List Minimum Efficiency Duct insulation requirement Area Thermostat ❑ Packaged Unit amore ❑ COP Over 40 ft of ducts added or , aback yli3:AFl1Eo tJuor Coil �SEER1� ❑ HSPF _ replaced in unconditioned space p p Served h system Y (lfnot atlreotle condensing Unit BEER 1,jL ❑ Resistance ❑ R 6 (CZ 10-1.3) ❑ R R (CZ 14-15) I(� sf present. must he installed) ❑ Other 1. Equipme►ht Type: Choose the eyaipnen being installed: if store than one ststenh, rase another CF -1 R -ALT -HMC for earls SYSI,em. 2. Minimum Equipment Efficiencies: 13 SEER, 78%AFUE, 7.7HSPFfor spiral residential ststents. HERS VERIFICATION SUMMARY Listed below are four HVAC alteration Options. The installer decides what work is being done and picks one of the appropriate Options. Each Option lists the HERS measures that must be conducted. A copy of the forms shall be left on site for final inspection and a copy given to the homeowner. At final, the inspector verifies that (he work listed on this form was in fact the work completed by the installer. The inspector also verifies that each appropriate CF -6R and registered CF -4R forms (no hand filled CF4Rs allowed) are tilled out and signed. Beginning October 1, 2010, a registered copy of the CF -IR and CF -6R shall also be on site for final inspection. 1. HVAC Changeout Required Forms: • All HVAC Equipment replaced CF -611 forms: MECH-04, MECH-2I-HERS and (for split systems) MECH- 25 -HERS CF -4I1 forms: MECH- 21 and (fors lits stems) MECH-25 • Condenser Coil and/or CF -6R forms: MECH-2I-HERS and (for split systems) MECH- 25 -HERS • Indoor Coil and /or CF -411 forms: MECH- 21 and (for split systems) MECH-25 • Furnace For Split Systems: Duct leakage < 15 percent; RC, CCA >_ 300 CFM/ton(Minimum Air Flow Requirement), TMAH For Packaged Units: Duct leakage < 15 percent Exempted from duct leakage testing if: ❑ I. Duct system was documented to have been previously sealed and confirmed through HERS verification, or ❑ 2. Duct systems with less than 40 linear feet in unconditioned space, or ❑ 3. Existing ducts stems are constructed, insulated or sealed with asbestos ❑ 2. New HVAC System Required Forms: • Cut in or Changeout with new CF -611 forms: MECH-04, MECH-20-HERS,and (for split systems) MECH-22-HERS, and MECH-25-HERS ducts: (a11 new ducting and all CF -411 forms: MECH 20-, and (for split systems)MECH-22, and MECH 25 new equipment) For Split Systems: Duct leakage < 6 percent; RC, CCA >_ 350 CFM/ton, FWD, TMAH, STMS, and either HSPP or PSPP. For Packaged Units: Duct leakage < 6 percent ❑ 3. New Ducts with Replacement Required Forms: • Includes replacing or installing all new ducting CF -611 forms: MECH-04, MECH-20-HERS,and (for split systems) MECH-25-HERS and/or outdoor condensing unit and/or indoor CF -411 forms: MECH-20 and (for split systems) MECH-25 coil and/or furnace. Not all equipment changed. For Split Systems: Duct leakage < 6 percent, RC, CCA >_ 300 CFM/ton, TMAH For Packaged Units: Duct leakage < 6 percent ❑ 4. New Ducting over 40 feet Required Forms: • Includes adding or replacing more than 40 CF -61Z forms: MECH-04, MECH-2I -HERS CF -4R forms: MECH-21 linear feet of duct in unconditioned space. For split system or packaged units: Duet leakage < 15 percent ❑ EXCEPTION: Existing ducts stems constructed, insulated or sealed with asbestos. Contractor (Documentation Author's/Responsible Designer's Declaration Statement) • 1 certify that this Certificate of Compliance documentation is accurate and complete. • l am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design identified on this Certificate of Compliance. • 1 certify that the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24. Pars I and 6 of the California Coale of Regulations. • The design features identified on this Cenifrcate of Compliance are consistent with the information documented on other applicable compliance forms, worksheem calculations, plans andspecifications submitted to the enforcement a encfora royal with the permit application. Name: r Signature: Compa \ ` Date- J _ ` 'l �� 1-1� ^ Address:\ LIN License: / City/State/Zip: Phone. - 10