Loading...
BRES2016-033378-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BRES2016-0333 Property Address: 54545 AVENIDA MADERO APN: I 774261003 Application Description: CORONEL / NEW SFD Property Zoning: . Application Valuation: . $135,659.80 Applicant: . CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 D VOICE (760) 777-7125 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 1/26/2017 Owner: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 727199 Date: _\-:)Jrl:j Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 70315, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 LIC. No.: 727199 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance ofa rk for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5009346 I certify that in the performance of Lie work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Se on 37 0 of th bo Co , I shall forthwith comply with those provisions. Date: k - X(' - k -J Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAG IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,00C). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FORlIN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owne4 and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this applicotion becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancell`3tion. I certify that I have read this application and.state that the above information is correct. I agree to comply with all city and county ordirs3nces and state laws relating to building construction, and hereby authorize representaives of t city toInter u on th above-mentioned property for inspection purposes. // Date: '\-)-(A__7 Signature (Applicant or Agent) Application Number: BRES2016-0333 Property Address: 54545 AVENIDA MADERO APN: 774261003 Application Description: CORONEL/ NEW SFD Property Zoning: Application Valuation: $135,659.80 Applicant: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Owner: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Date: 1/26/2017 (760)775-1234 Llc. No.: 727199 - -------------------------------------------------------------------------------------------- Detail: NEW 2104 SQ. FT. SFD THIS.PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, BBQ, FORE PIT OR WATER FEATURE. THIS HOME IS FIRE SPRINKLED PER 2013 CRC CODES. FINANCIAL ' DESCRIPTION ACCOUNT QTY AMOUNT BSAS 561473 FEE 101-0000-20306 0 $6.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - LIBRARIES. 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY. DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $17.73 Total Paid for ELECTRICAL: $43.06 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $25.84 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 .0 $10.64 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $238.64 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $38.00 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $38.00 Total Paid for GRADING: $76.00 DESCRIPTION ACCOUNT QTY AMOUNT ' 4 CONDENSER/COMPRESSOR 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.07 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY. AMOUNT VENT FAN 101-0000-42402 0 $63.35 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $25.35 Total Paid for MECHANCAL: $233.10' DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2016 UPDATE 101-0000-20310 0 $1,221.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $1,221.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $554.50 Total Paid for NEW CONSTRUCTION PERMIT: $554.50 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $750.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $355.38 Total Paid for NEW CONSTRUCTION PLAN CFECK: $1,105.38 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT ' BACKFLOW DEVICE PC 101-0000-42600 0 $5.07 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $17.73 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $139.37 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $139.37 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 DESCRIPTION .'ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING [FEES: $448.48 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $17.64 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $17.64 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDEMTIAL: $1,837.44 $12,680.24 `".t �. �' 4u+.YiN►:tW""� _���• t y(.. 1 -�w �.`- -• f ! 1 ,''/�\/ (,t • 'P.O. BOX 1504 APPLICATION ONLY �. -���" `t,, 78-495 CALLE TAMPICO Building: �'-•�^ �., Address .i< , �.�e Cc LA QUINTA, CALIFORNIA 92253_` - Owner - zv+� BUILDING: TYPE CONST. OCC. GRP. Mailing\ .�'I`i Address A.P.Number \apb . \\ • S!e g b • Cit Zip ]Tel. Legal Description�� • 3s Cc actor �� Project Description ' y ' Address �r _ & Classif. -7 3-71 x Arch., Engr., Designer C, Tel. ado -i w-7 a City .,. Sq. Ft. No.:. Lic. # �• Size Stories 'r Newi;Z Add ❑ Alter ❑ LAW \\ Lip State LICENSED CONTRACTOR'S DECLARATION _ I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and - effect. :. . SIGNATURE - DATE - - OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the fallowing r n' S 7031 5 B • AD l C d A h' h No. Dw.. Units Repair ❑ . „ , Demolition ❑ Baso . (ec. usmess an ro ss ns o e. ny city or county w is requ res a permit to construct, alter, improve,demolish, or repair any structure, prior to its issuance also 'PERMIT, AMOUNT requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis 'Plan Chk Dep: - for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects ' the applicant to a civil penalty of not more than five hundred dollars ($500). Plan Chk. Bal. ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do - the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- Const. Bions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided - Mech. that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of, Electrical proving that he did not build or improve for the purpose of sale). Plumbing` ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct Business Professions The the project. (Sec. 7044, and Code: Contractor's License Law does S.M.I. - not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) Grading ❑ 1 am exempt under Sec. B. & P.C. for this reason . ,• •. ', Driveway.Enc. Date owner Infrastructure WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) , Policy No.- Company ❑ Copy is filed with the city. O Certified copy is hereby furnished. • CERTIFICATE OF EXEMPTION FROM ,•" TOTAL, WORKERS' COMPENSATION INSURANCE • - ' - - (This section need not be completed if the permit is for one hundred dollars ($100) valuation REMARKS ` or less). I certify that in the performance of the work for which this permit is issued, I shall not _ employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, alter making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith ' , comply with such provisions or this permit shall be deemed revoked. ZONE: 4 BY: V., Minimum Setback '• Distances: - CONSTRUCTION LENDING AGENCY -. - ' " Front Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work Rear Setback from Rear Prop. Line for which this permit is issued. (Sec. 3097, Civil Code.) fi s - Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to Side Street Setback from Center Line Side Setback from Property Line expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. FINAL DATE INSPECTOR agree to comply with all city and county ordinances and state laws relating to building . _vtl construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Issued by: Date Permit + r • • • Signature of applicant Date . ' ' .. 5 Mailing Address Validated by: . City, State, Zip ; ' Validation: r WHITE = BUILDING DEPARTMENT'. YELLOW= APPLICANT _ PINK = FINANCE CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date: 1/25/2017 La Quinta, CA 92253 No.: 17-00479-1 (760)771-8515 Owner:.Coronel J��f1Ep S c p) BE a DUt1ES • 'RAkMtp O MIRAGE � f 'wrnrwwEus, y uott��INTA � Address: Jurisdiction: La.Quinta City: Tract #: Type: Single Family Residential Lot # Street No. Street Name Sq. Feet APN Permit No. 54545 Avenida •Madero 2104 774-261-003 Comments: At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at,this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.48 X 2104 S.F. or $7,321.92 have been paid for the property Fisted above and that building permits and/or Certificates of Occupancyfor this square footage in the proposed project may now be issued. Check No.: 8006317 Fees Paid By: CC/Rabobank - Ish Coronet Telephone: Bank Name/Recipient of Certificate Funding: Residential By Kathleen Felci Interim Superintendent Fee Collected/ Exempted by: Sharo cG' rey. Certificate Fees Due: $7-321'.92, all Payrhent(s) Recd.` $0.00- _ New Paymehi'Rec'd " $ 321.y�� `�✓fir/Under: $0.W5 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that 90 -day approval period in which you.may protestYthe fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. BUILDING ENERGY ANALYSIS REPORT - PROJECT: Staker's Residence 54545 Avenida Madero - APN.: 774-261-003 La. Quinta, Ca 92253 Project Designer: Santiago Lopez Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Report Prepared by: f Santiago Lopez-Ocampo Santiago Lope z -H nq F LA Q lJ I NTA P.O. Box 1 LDING & SAFETY DEPT,. La Quinta; C PR VE® 760.485, 927FOR CONSTR CTION DATE BY ;lob Number: LQQ93016 - Rev131316 RECEIVED' DEC 2 3 2016 Date: CITY of U". OUINTA ..12/21120.16 COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. ` Energ Pro 6.7 by EnergySoR User Number 5732, - ID: LQ093016 - Rev1313 " BUILDING ENERGY ANALYSIS REPORT - PROJECT: Staker's Residence 54545 Avenida Madero - APN.: 774-261-003 La. Quinta, Ca 92253 Project Designer: Santiago Lopez Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 Report Prepared by: f Santiago Lopez-Ocampo Santiago Lope z -H nq F LA Q lJ I NTA P.O. Box 1 LDING & SAFETY DEPT,. La Quinta; C PR VE® 760.485, 927FOR CONSTR CTION DATE BY ;lob Number: LQQ93016 - Rev131316 RECEIVED' DEC 2 3 2016 Date: CITY of U". OUINTA ..12/21120.16 COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. ` Energ Pro 6.7 by EnergySoR User Number 5732, - ID: LQ093016 - Rev1313 Cover` Page 1 Table of Contents 2 .Form CF -1R -PRF -01 -E'Certificate.of Compliance 3 Form RMS -1 Residential Measures Summary 12 Form MF -1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml CF1 R -PRF -01 Page 1 of 9 GENERAL INFORMATION 01 01 Project Name Staker's Residence 04 02 02 Calculation Description Title 24 Analysis Ar 03 03 Project Location 54545 Avenida Madero - APIC: 774-261-003 .- 3 Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 .07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Pond. Floor Area (ftZ) 2104 ' 15 Number of Zones 1 16 Slab Area (ft) 2104 17 Number of Stories 1 18 Addition Cond. Floor Area N/A . " 19 Natural Gas Available No 20 Addition Slab Area (ftZ) I N/A 21 Glazing Percentage (%) 18.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performances f f -x' ` > t 04 02 This building Incorporates features.that require fieldtesting'and/or.venfication,by a certified HERS rater, un lerthe supervision of a CEC-approved HERS provider. 07 Ar 03 This building incorporates one ormore Special Features shown below f• Proposed Design .- 3 Percent Improvement Registration Number: 216-N0360685B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.36 1.49 0.87 36.9% Space Cooling 79.96 77.19 2.77 3.5% IAQ Ventilation 1.08 1.08 0.00 0.0% Water Heating 29.39 17.72 11.67 39.7% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 112.79 97.48 15.31 13.6% Registration Number: 216-N0360685B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xm1 REQUIRED SPECIAL FEATURES TCe following are features tCat must Ce installed as condition For meeting tCe modeled energy performance Cdr tCis computer analysis. ❑ Window overhangs and/or fins ❑ ECposed slab floor in conditioned zone HERS FEATURE SUMMARY TCe following is a summary oCtCe features tCat must Ce field -verified Cy a certilied ❑ERS Rater as a condition Cdr meeting tCe modeled energy performance For tEis computer analysis. Additional detail is provided in tCe Cuilding components taCles Celow. Building -level Verifications: ❑ IAQ mechanical ventilation Cooling System Verifications: ❑ Minimum Airflow ❑ Verified EER ❑ Verified SEER ❑ Refrigerant Charge *+ 0 Fan Efficacy Watts/CFM HVAC Distribution System Verifications: ❑ Duct Sealing ❑ Low -leakage Air Handling Unit Domestic Hot Water System Verifications: ❑ -- None — qy P J a e 8 W' ENERGY DESIGN RATING TGs is tCe sum oCtCe annual TDO energy consumption [or energy use components'included'in tCeperformance compliance approac❑ Cor tCe Standard Design Building (Energy Budget) and tCe annual TDO energy consumption for IigCting and components not regulated Cy Title 24; Part'6 (suc❑as domestic appliances and consumes electronics) and accounting for tCe annual TDO energy offset Cy an on-site renewaCle energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)❑ 167.64 152.33 15.31 9.1% ❑includes calculated Appliances and Miscellaneous Energy ❑se (AME❑) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (f:2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Staker's Residence 2104 1 3 1 0 1 Registration Number: 216-N0360865B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Stalker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 3 of 9 Calculation Description: Title 24 Analysis Input File Name:'54545 Avenida Madero - Staker - Rev121316.xm1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 WEole Douse Conditioned ❑CAC Systeml 2104 10 DOW Sys 1 Gross Area (ft2) OPAQUE SURFACES 01 02 03 4i 1� 04 01 02 03 04 05 06 07 08 Name Zone Construction ..Azimuth Orientation Gross Area (ft2) Window ❑ Door Area (W) Tilt (deg) Ri/N WCole Douse R-21 Wall w/1 EPS 0 Rig[t 600 71 .90 Re/W WCole Douse R-21 Wall w/1 EPS 270 Back 400 243.401 90 Le/S WCole Douse R-21 Wall w/1 EPS 180 Le[tl 760. 22.5 90 Fr/E WCole Douse "_ R-21 Wall w/1 EPS. 90 Front ., 191.6. 54.9123 90 Roo[2 WCole Douse R-38 RooCAttic RB 2101.5 OPAQUE SURFACES OCathedral Ceilings,', '�` 01 02 03 4i 1� 04 05 �� ,O6 07 08 09 10 11 . "Orientatio'` f # Skylight Area Roof Rise-- Roof` Roof Tilt Roof Roof Framing Name Zone... '�-, TYPe3 .�: � '7 . n- � Area (ft2y r "(ft2)', .t - � (D'in;12),;, b` yP�itch (deg) Reflectance Emittance ..Factor RooD. WCole Douse R-38 RooCAttic R61 RigEt' 2.6 Y 2.5. 0.2 0.02 0.95 0.1 0.85 0.1 ATTIC 01 02 03 04 05 06 J 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic WFole Douse Attic RooLWCole Douse Centilated 0.2 0.1 0.85 Fes No Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml CF1 R -PRF ;01 Page 4of9 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipli er Area (ft) U -factor SHGC ECterior Shading 5050 13ed3 Window RUN (Rig[t-0) ---- -- 1 25.0 0.30 0.22 [hsect Screen (default) 5016 Bed3 Transom Window Ri/N (Rig[t-0) ---- -- 1 7.5 0.28 0.25 [hsect Screen (de[ault) 5050 Bed2 Window Ri/N (Rig[t-0) ---- ---- 1 25.0 0.30 0.22 [hsect Screen (default) 5016 13ed2 Transom V\Andow Ri/N (RigCt-0) ---- --- 1 7.5 0.28 0.25 [hsect Screen (de[ault) 4016 Master Bat❑ Window RUN (RigCt-0) ---- ---- 1 6.0 0.28 0.25 Cnsect Screen (default) 3080 MBed Window Re/W (Back -270) 5.3 1.5 3.048 24.0 0.47 0.24 [hsect Screen (de[ault) 8080 SOD MBed Wndow Re/W (Back -270) ---- ---- 1 64.0 0.47 0.24 I sect Screen (de[-ault) 3080 MBed 2 VNndow ReM/(Back-270) 5.3 1.5 3.048 24.0 0.47 0.24 insect Screen (de[-ault) 3080 FrDr Living Window Re/VV (Back -270) ---- ---- 1 12.0 0.36 0.35 Cnsect Screen (de[ault) 3016 Living Transom Window Re/W (Back -270) 3.0 1.5 1 4.5 0.28 0.22 Cnsect Screen (default) 12280 SOD Dining/❑itcCen Window Re/W (Back -270) ---- ---- 1 97.3 0.47 0.24 nr sect Screen (default) 51016 Living Transom Window Re/W (Back=270) . t"' �{ 5.8 1.5 11.00.6 �78.8 0.28 0.22 insect Screen (def-ault) 51016 Living Transom 2 Window t _ 3; { $t, Re/W (Back -270) x s 58 11.5 -; e x1.006 4.8.8; 0.28 0.22 [-resect Screen (default) 5016 Living Transom Window Le/S Le[t-180 ( ) -* -- 1 W 7.5 0.28 0.25 [resect Screen (de[ault) 5016 Dining Transom V\Andow Le/S (Le[t=180) --- --- 1 7.5 0.28 0.25 [-resect Screen (default) 5016 ❑itcCen Transom Window Le/S (Le[t=180) --- ---- 1 7.5 0.28 0.25 Cnsect Screen (de[-ault) 5016 Fix Laundry Window Fr/E (Front -90) 6.3 2.3 0.527 7.5 0.28 0.22 insect Screen (default) 5016 Fix Laundry 2 V\Andow Fr/E (Front -90) 6.3 2.3 1.004 14.3 0.28 0.22 [hsect Screen (default) . 3080 FrDr Entry Window Fr/E (Front -90) ---- ---- 1 12.0 0.36 0.35 [hsect Screen (default) 4916 Entry Transom V\Andow Fr/E (Front -90) 6.3 2.3 0.499 7.1 0.28 0.22 insect Screen (default) 1980 Entry Sidelite V\Andow Fr/E (Front -90) --- - 1 14.0 0.28 0.22 Chsect Screen (default) 10 SolatuCe 1 SkyligCt RooC(Rig[t-0) 1 .5 0.61 0.27 10 SolatuCe 2 SkyligCt RooQRig[t-0) 1 .5 0.61 0.27 10 SolatuCe 3 SkyligCt Roo[(Rig[t-0) 1 .5 0.61 0.27 10 SolatuCe 4 SkyligCt RooC(Rig[t-0) 1 .5 0.61 0.27 10 SolatuCe 5 Skylig[t RooC(RigCt-0) 1 .5 0.61 0.27 Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - U111-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml CF1 R -PRF ;01 Page 5of9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 05 ., Overhang Left Fin Right Fin Window Depth Left Dist Up ECtent Right EF -tent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 3080 MBed 4 1 4 4 0 0 0 0 0 0 0 0 0 3080 MBed 2 4 1 4 4 0 0 0 0 0 0 0 0 0 3016 Living Transom 7.5 1 4 4 0 0 0 0 0 0 0 0 0- 51016 Living Transom 7.5 1 4 4 0 0 0 0 0 0 0 0 0 51016 Living Transom 2 7.5 1 4 4 0 0 0 0 0 0 0 0 0 5016 Fix Laundry 4 0.91 4 4 0 0 0 0 0 0 0 0 0 5016 Fix Laundry 2 4 0.91 4 4 0 0 0 0 0 0 0 0 0 4916 Entry Transom 6.5 1 0.66 0.66 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS, 01 02 03 .. w 04 05 ., 06 07 Name Zone Area (W) Perimeter (ft) Cavity , Winter Design Heated Construction Name Surface Type CoCCnstruction Type:.m� j Framuig ^¢Total R -value ( �,U-value Assembly Layers • P ` � � t=`�'�%` Cavity /Frame: no insul. / 2x4 Top Chrcl 2x4: Top CCord o Roo -Truss 0 24 1_.. `'-fir t" 3� �r Roof Deck: Wood Siding/sheathing/decking Attic RooLWDole Douse Attic Roofs Wood Framed Ceiling- 4r in O.C. none 0644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Sheathing/ Insulation: R5 Sheathing • Exterior Finish: Wood R-21 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x6 D 16 in. D.C. R 21 0.047 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (Celow Cavity/Frame: R-9.1 /2x4 R-38 Roo[Attic RB attic) Wbod Framed Ceiling 2x4 0 16 in. D.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 RooCAttic R61 CatCedral Ceilings Wood Framed Ceiling 2x4 0 16 in. D.C. R 38 0.041 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (W) Perimeter (ft) Edge Insul. R -value 0 Depth Carpeted Fraction Heated Slac-on-Grade WCole Douse 2104 0.1 None 0 No Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml BUILDING ENVELOPE - HERS VERIFICATION 01 .02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not ReCuired - Not ReCuired Not Re[Uired --- CF1 R -PRF ;01 Page 6 of 9 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DOWSys 1 - 1/1 DOW Pipe Chsulation, All Lines DOW ❑eater 1 1 .0% WATER HEATERS 01 02. 03 04 05 06 07 08 ❑CAC Fan 1 Air DistriCution System 1 Tank El terior Tank Volume Energy Factor or Central DHW Insulation Standby Loss Name Heater Element Type :_ Tank Type (gal) Efficiency Input Rating R -value (Fraction) DOW Dealer 1 Propane Small nr stantaneous, 0 0.84 185000-Btu/Cr 0 0 - k : ,� . r.R- o .r: �- et WATER HEATING - HERS VERIFICATION 01 01 02 » ` 'U3 a }_ .N E 04' Fan Name Distribution Name 06 07 ❑CAC Fan 1 Air DistriCution System 1 Recirculation Central DHW Name Pipe Insulation Parallel Piping Compact Distribution, Point -of Use Control Distribution DOWSys 1 - 1/1 --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:❑eating Component 1:Air DistriElution System 1:❑CAC Fan 1:1 ❑tCer Dealing and Cooling Dealing Component 1 Cooling Component 1 System ❑CAC Fan 1 Air DistriCution System 1 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Ceating Component 1 CntrlFurnace - Fuel -tired central Curnace 92 AF❑E Registration Number: 216-No360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml CF1 R -PRF -01 Page 7 of 9 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 14 15 Not Zonal Single Speed Cooling Component 1-Cers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-Cers-cool ReCuired 350 ReCuired ReCuired ReCUired HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06, 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air DistriCution System 1 DuctsAttic /+." t « Specilied Lower,Leakage . r - -- r �^ Tar et 1 , i 8 t - g. ls�.-.,r:6 Attic ;i' z;*. .x�. � r Air DistriCution System None 1-Cers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 € e w 03�' ` i- 041' ,.- sa 05 ': �" t`-`4.06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air DistriCution System 1-7ers-dist ReCuired 6.0 Not ReCuired Not ReCuired Not ReCuired Not ReCuired ReCuired HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power(Watts/CFM) HERS Verification ❑CAC Fan 1 Single Speed PSC Furnace Fan 0.58 ❑CAC Fan 1-Cers-an HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) ❑CAC Fan 1-Cers-!an ReCuired 0.58 Registration Number: 216-No360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE'- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Stalker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 8 of 9 . Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xm1 IAQ (Indoor Air Quality) FANS 01 02" 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam I-AQCentRpt 51.04 0.25 Default 0 ReCuired h Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc. CA Building Energy. Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316:xm1 CFI R -PRF ;Q1 , Page 9of9 DOCUMENTATION AUTHORS DECLARATION STATEMENT 1. CcertiCy t[at tEis Certificate oCCompliance documentation is accurate and complete. Documentation AutCor Name: Santiago LopeC Documentation AutCor Signature: E)campo Company: Signature Date: Santiago LopeE Dcampo 2016-12-21 01:24:06 Address: CEA/❑ERS Certification I-denti[cation (EapplicaCle): P.D. Box 1018 na City/State/Zip: PCone: La Quinta, CA 92247 760-485-8927 RESPONSIBLE PERSONS DECLARATION STATEMENT tCe Collowing under penalty o[periury, under [e laws o[tCe State oLCaliCornia: _CcertiCy 1. Cam eligiCle under Division 3 oCtCe'Business and Professions Code to accept responsi[ility For tCe CUilding design identified on tCis Certificate oCCompliance. 2. CcertiCy tCat tCe energy features and performance speci[ications identified on tCis Certificate oCCompliance conlorm to Ice recuirements o❑Title 24; Part 1 and Part 6 oCtCe California Code o❑ Regulations. 3. TCe Cuilding design features '& *system design features identified on t[is Certificate oCCompliance are consistent witotCe information provided on otCer applica[le compliance documents, ' worksCeets, calculations, plans and specifications suCrnitted to,tCe enrorcement agency,Jbr approval vAt❑t[is.CUilding permit application. •Responskle Responsi[le Designer Name: ; " Designer Signature: , scoSantiago Lope ❑Campo _ I `+ ,- .. :: t Company:..I'a! Date.Signed: .� Santiago LopeC Ocampo 2016-12-21 01:24:06 Address: License: 'P.D. Box 1018 na City/State/Zip: PCone: La Quinta, CA 92247 760-485-8927 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of.this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-N0360865B-000000000-oobo Registration Date/Time: 2016-12-21 01:24:06 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-12-2101:09:37 RESIDENTIAL MEASURES SUMMARY RMS -1 Protect Name StakerFs[Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing ❑Addition/Alteration Date 12/21/2016 Pro[ect Address 54545[I venida®aderoGFACO.: ®❑4-261-❑ Cali[ornia Energy Climate ZoneTotal CACClimate®oneC15 Cond. Floor Area 211 E14 Addition n/a ❑o®nits 1 INSULATION Construction Type Area Cavi (ft) Special Features Status Sla❑ Dnheated[Sla0•on-Grade -tihoUbsulationl 2C1D4 ❑erim®® DeO Demising Wood[Frramed R121 341 DeO Wall Wood[Frramed R121 11560 Rigid[R-5.0 ❑e0 Roof WbodrlFramedFAttic R[38 2[102 ❑e0 FENESTRATION Orientation Area(ft2) I Total Area: 394 ❑lacing Percentage: 18•® U -Fac SHGC Overhang Sidefins New/Altered Average 0 -Factor: D39 E[terior Shades Status RightmD) 500 D30D 022 none none Bug[Screen De❑ Right[60) 21.0 0280 D25 none none Bug[Screen DeO Rear((jVlq 48.0 D40D D24 4.0 none Bug[Screen De0 Rearr(11M 161.3• 0400 D24 none none Bug1screen ❑e0 Rearfl604 12.0 D360 D35 none none Bug[Screen De0 Rear[OK9 22.1 D280 022 05 none Bug[Screen De0 LOW) 22.5 0280 D25 none none Bug[Screen DeO Frontr(E) 21.8 [1280 D22 4.0 none Bug[Screen De❑ FrontQE) 12.0 0360 035 none none Bug[Screen ❑eO Front[QE) D.1 D280 022 6.5 none Bug[Screen ❑eD Front[VE) 14.0 D280 022 none none Bug[Screen ❑e❑ Skylight 05 0610 D20 none none Done DeO Skylight D5 0610 0.20 none none Done De❑ Skylight D5 0610 D20 none none Done DeO HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 CentralrFumace 920 [SIF❑E Split[Air[Conditioner 15.DESEER Set❑ack ❑e0 HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status 0❑AC[System Ducted Ducted Attic 8.0 ❑e0 WATER HEATING Qty- Type Gallons Min. Eff Distribution Status 1 Small[Instantaneous[Gas 0 D84 All®ipesUns ❑e0 Ener-qyDro16.D[fl1y1Ene ySoft DSeraDUmCer[5032 RunCode:2016-12-21T01:16:26 ID:rLDC93D16GrIRev1313 Da eC12[A08 RESIDENTIAL MEASURES SUMMARY RMS-1 Protect Name Stakerlg[Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing ❑Addition/Alteration Date 12/21/2016 Pro(ect Address 54545 1venida®adero2FA❑❑.:�❑4-261-❑ California Energy Climate Zone CACClimate®oneC15 Total Cond. Floor Area 2[104 Addition❑omnits n/a 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Orientation Area(ft2) Total Area: 394 ❑laCing Percentage: 18.7 % New/Altered Average ❑-Factor: U-Fac SHGC Overhang Sidefins ECterior Shades 0.39 Status Skylight ❑5 ❑610 E12❑ none none Done ❑e❑ Skylight 115 11610 D2❑ none none Done ❑e❑ HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty- Type Gallons Min. Eff Distribution Status Ene orof6. 0ffjy[EnefgySoft ❑ser00um1er15D32 RunCode:2016-12-21701:16:26 IDADD93❑16GFRev1313 ❑a eC13[bA=18 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply ivith all applicable mandaton, measures listed, regardless of the compliance approach used. Exceptions niay apvly. Review the respective code section for more information. Building Envelope Measures: §i 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § i 10.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110 8(1): The thernial enuttance and aged solar reflectance values of the cool roofing material meets the requirements of § i 10.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have pernianently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § I50.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §I50.0(d): Minimum R -i9 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior §i50.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over tine earth floor of § I50.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for tine insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 penm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8(g). 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58: or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e) IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)IB: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § I50.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § I50.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to tine outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage comiection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. §I50.0(ln)1: Heating and/or cooling loads are calculated in accordance with ASHRAE. SMACNA or ACCA using design conditions specified it § 150.0(h)2. § I50.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thernnal resistance of R-12 or greater. §150.0(j)IB: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or uiburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.0(j)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §I50.00)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § I50.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside tennimation and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200.000 Btu/hr. § l50.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § I50.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/n inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § i 50.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(nm)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion filet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not §150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)]0: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §I50.0(m)l l: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of § l 50.0(m) l 2. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for tine placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §i50.0(m)13: space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confinned by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control node, § I50.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling umits shall meet time requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting time thermostat setting: a permanent weatherproof plate or card with operating instructions: and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction § 110.4(b)1: and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- granmied to nm only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)lA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § I50.0(k)1 B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with tile applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be detennined in accordance with § 150.0(k)I C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting per electrical box. §I50.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)1F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy lununaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § I50.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. §I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § I50.0(k)2E: No control shall bypass a dimmner or vacancy sensor function if the control is installed to comply with § 150.0(k). § I50.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer § i 50.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § i 50.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. §150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2. § I50.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy lununaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy. or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory, have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk, and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting pernianently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astrononnical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4, meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §I50.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, §140.7 and § 141.0. § I50.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § I50.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § I50.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §I50.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § l 30.0, § 130. 1, § 130.4, `140.6, and § 141.0. In a low-rise multifannily residential building where the total interior commion area in a single building equals 20 percent or less of §150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of tine floor area, permanently installed lighting in that building shall: § 150.0(k)12B: n. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fiilly Om and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10(b) through § l 10.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. §1 10.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the infornnation from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §I 10.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § l 10.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and pernianently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Staker's Residence 12/21/2016 System Name Floor Area HVAC System 2,104 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,135 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80,000 23,385 2,522 414 16,151 Total Output (Btuh) 80,000 0 Output(Btuh/sgft) 38.0 1,350 794 Cooling System 0 0 Output per System 59,500 0 0 0 0 Total Output (Btuh) 59,500 0 2,522 0 Total Output (Tons) 5.0 1,350 794 Total Output (Btuh/sgft) 28.3 Total Output (s ft/Ton) 424.3 1 26,085 17,738 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 York H4TS060S06 41,033 9,393 80,000 Airflow (cfm/sgft) 0.95 Airflow (cfm/Ton) 403.4 80,000 Jan 1 AM Outside Air (%) 1 0-0% Total Adjusted System Output 1 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 41,0331 9,393 Aug 3 PM Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures. at Time of Heating Peak) 26 OF 68 OF 68 OF 105 OF Outside Air» - 0 cfm Supply Fan Heating Coil 105 OF 2,000 dm -- -.- -- ROOM 68 OF 68 OF dog COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76!62°F 76162°F 55/54°F Outside Air I :.. ..... ..-. 0 cfm Supply Fan Cooling Coil 56 / 54 OF 2,000 cfm 47.6% ROOM i 76 ! 62 OF 75 / 62 OF EnergyPro 6.7 by EnergySoff User Number. 5732 RunCode: 2016-12-21T01:16:26 ID: LQ093016 - Rev1313 Page 18 of 18