BRES2016-033378-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
BRES2016-0333
Property Address:
54545 AVENIDA MADERO
APN: I
774261003
Application Description:
CORONEL / NEW SFD
Property Zoning: .
Application Valuation: .
$135,659.80
Applicant: .
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
D VOICE (760) 777-7125
FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 1/26/2017
Owner:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 727199
Date: _\-:)Jrl:j Contractor.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 70315, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(� I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(� I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractors) licensed pursuant to
the Contractors' State License Law.).
( I I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Add
Contractor:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
(760)775-1234
LIC. No.: 727199
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
ofa rk for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5009346
I certify that in the performance of Lie work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Se on 37 0 of th bo Co , I shall forthwith
comply with those provisions.
Date: k - X(' - k -J Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAG IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,00C). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FORlIN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owne4 and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this applicotion becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancell`3tion.
I certify that I have read this application and.state that the above information is correct.
I agree to comply with all city and county ordirs3nces and state laws relating to building
construction, and hereby authorize representaives of t city toInter u on th
above-mentioned property for inspection purposes. //
Date: '\-)-(A__7 Signature (Applicant or Agent)
Application Number: BRES2016-0333
Property Address:
54545 AVENIDA MADERO
APN:
774261003
Application Description:
CORONEL/ NEW SFD
Property Zoning:
Application Valuation:
$135,659.80
Applicant:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
Owner:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
Contractor:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
Date: 1/26/2017
(760)775-1234
Llc. No.: 727199
-
--------------------------------------------------------------------------------------------
Detail: NEW 2104 SQ. FT. SFD THIS.PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, BBQ, FORE PIT OR WATER FEATURE. THIS
HOME IS FIRE SPRINKLED PER 2013 CRC CODES.
FINANCIAL '
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS 561473 FEE
101-0000-20306 0 $6.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - LIBRARIES.
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY. DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$17.73
Total Paid for ELECTRICAL: $43.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$25.84
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
.0
$10.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$152.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$50.16
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $238.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF
101-0000-42408
0
$38.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC
101-0000-42600
0
$38.00
Total Paid for GRADING: $76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
' 4
CONDENSER/COMPRESSOR
101-0000-42402
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE
101-0000-42402
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE PC
101-0000-42600
0
$25.33
DESCRIPTION
ACCOUNT
QTY.
AMOUNT
VENT FAN
101-0000-42402
0
$63.35
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$25.35
Total Paid for MECHANCAL: $233.10'
DESCRIPTION
ACCOUNT
QTY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2016 UPDATE
101-0000-20310
0
$1,221.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,221.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$554.50
Total Paid for NEW CONSTRUCTION PERMIT: $554.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$750.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$355.38
Total Paid for NEW CONSTRUCTION PLAN CFECK: $1,105.38
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT '
BACKFLOW DEVICE PC
101-0000-42600
0
$5.07
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$17.73
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$139.37
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$139.37
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$7.60
DESCRIPTION
.'ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.67
Total Paid for PLUMBING [FEES: $448.48
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$17.64
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $17.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SINGLE FAMILY DETACHED
224-0000-20320
0
$1,837.44
Total Paid for TUMF - RESIDEMTIAL: $1,837.44
$12,680.24
`".t �. �' 4u+.YiN►:tW""� _���• t y(.. 1 -�w �.`- -• f ! 1 ,''/�\/ (,t
• 'P.O. BOX 1504 APPLICATION ONLY
�. -���" `t,, 78-495 CALLE TAMPICO
Building: �'-•�^ �.,
Address .i< , �.�e Cc LA QUINTA, CALIFORNIA 92253_` -
Owner -
zv+� BUILDING: TYPE CONST. OCC. GRP.
Mailing\ .�'I`i
Address A.P.Number
\apb . \\ • S!e g b •
Cit Zip ]Tel. Legal Description�� • 3s
Cc actor �� Project Description ' y
'
Address �r _
& Classif. -7 3-71 x
Arch., Engr.,
Designer C,
Tel.
ado
-i w-7 a
City .,. Sq. Ft. No.:.
Lic. # �• Size Stories 'r
Newi;Z Add ❑ Alter ❑
LAW \\ Lip State
LICENSED CONTRACTOR'S DECLARATION _
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section
7000) of Division 3 of the Business and Professions Code, and my license is in full force and -
effect. :. .
SIGNATURE - DATE - -
OWNER -BUILDER DECLARATION Estimated Valuation
I hereby affirm that I am exempt from the Contractor's License Law for the fallowing
r n' S 7031 5 B • AD l C d A h' h
No. Dw..
Units
Repair ❑ . „ , Demolition ❑
Baso . (ec. usmess an ro ss ns o e. ny city or county w is requ res a
permit to construct, alter, improve,demolish, or repair any structure, prior to its issuance also
'PERMIT,
AMOUNT
requires the applicant for such permit to file a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis
'Plan Chk Dep:
-
for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects '
the applicant to a civil penalty of not more than five hundred dollars ($500).
Plan Chk. Bal.
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
-
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
Const.
Bions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon and who does such work himself or through his own employees provided -
Mech.
that such improvements are not intended or offered for sale. If, however, the building or im-
provement is sold within one year of completion, the owner -builder will have the burden of,
Electrical
proving that he did not build or improve for the purpose of sale).
Plumbing`
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct
Business Professions The
the project. (Sec. 7044, and Code: Contractor's License Law does
S.M.I.
-
not apply to an owner of property who builds or improves thereon, and who contracts for such
projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
Grading
❑ 1 am exempt under Sec. B. & P.C. for this reason
. ,• •. ',
Driveway.Enc.
Date owner
Infrastructure
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) ,
Policy No.- Company
❑ Copy is filed with the city. O Certified copy is hereby furnished.
• CERTIFICATE OF EXEMPTION FROM
,•" TOTAL,
WORKERS' COMPENSATION INSURANCE • - '
- -
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
REMARKS
`
or less).
I certify that in the performance of the work for which this permit is issued, I shall not
_
employ any person in any manner so as to become subject to Workers' Compensation Laws of
California.
Date Owner
NOTICE TO APPLICANT.. If, alter making this Certificate of Exemption you should become
subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith
' ,
comply with such provisions or this permit shall be deemed revoked.
ZONE: 4
BY:
V.,
Minimum Setback
'•
Distances:
- CONSTRUCTION LENDING AGENCY -. -
' " Front Setback from Center Line
I hereby affirm that there is a construction lending agency for the performance of the work
Rear Setback from Rear Prop. Line
for which this permit is issued. (Sec. 3097, Civil Code.) fi
s
-
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
Side Street Setback from Center Line
Side Setback from Property Line
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
FINAL DATE
INSPECTOR
agree to comply with all city and county ordinances and state laws relating to building .
_vtl
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Issued by:
Date Permit
+ r • •
• Signature of applicant Date
. '
'
..
5
Mailing Address
Validated by:
.
City, State, Zip ;
' Validation:
r WHITE = BUILDING DEPARTMENT'.
YELLOW= APPLICANT
_ PINK = FINANCE
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
Date: 1/25/2017 La Quinta, CA 92253
No.: 17-00479-1 (760)771-8515
Owner:.Coronel
J��f1Ep S
c
p) BE a DUt1ES •
'RAkMtp O MIRAGE �
f 'wrnrwwEus, y
uott��INTA �
Address: Jurisdiction: La.Quinta
City: Tract #:
Type: Single Family Residential
Lot # Street No. Street Name Sq. Feet APN Permit No.
54545 Avenida •Madero 2104 774-261-003
Comments:
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at,this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.48 X 2104 S.F. or $7,321.92 have been paid for the property Fisted above and that building
permits and/or Certificates of Occupancyfor this square footage in the proposed project may now be issued.
Check No.: 8006317
Fees Paid By: CC/Rabobank - Ish Coronet Telephone:
Bank Name/Recipient of Certificate Funding: Residential
By Kathleen Felci
Interim Superintendent
Fee Collected/ Exempted by: Sharo cG' rey. Certificate Fees Due:
$7-321'.92,
all Payrhent(s) Recd.` $0.00- _
New Paymehi'Rec'd " $ 321.y��
`�✓fir/Under: $0.W5
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that 90 -day approval period in which you.may protestYthe fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
BUILDING ENERGY ANALYSIS REPORT
- PROJECT:
Staker's Residence
54545 Avenida Madero - APN.: 774-261-003
La. Quinta, Ca 92253
Project Designer:
Santiago Lopez Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Report Prepared by:
f Santiago Lopez-Ocampo
Santiago Lope z -H nq F LA Q lJ I NTA
P.O. Box 1 LDING & SAFETY DEPT,.
La Quinta; C PR VE®
760.485, 927FOR CONSTR CTION
DATE BY
;lob Number:
LQQ93016 - Rev131316 RECEIVED'
DEC 2 3 2016
Date:
CITY of U". OUINTA
..12/21120.16 COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com. `
Energ Pro 6.7 by EnergySoR User Number 5732, - ID: LQ093016 - Rev1313
"
BUILDING ENERGY ANALYSIS REPORT
- PROJECT:
Staker's Residence
54545 Avenida Madero - APN.: 774-261-003
La. Quinta, Ca 92253
Project Designer:
Santiago Lopez Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Report Prepared by:
f Santiago Lopez-Ocampo
Santiago Lope z -H nq F LA Q lJ I NTA
P.O. Box 1 LDING & SAFETY DEPT,.
La Quinta; C PR VE®
760.485, 927FOR CONSTR CTION
DATE BY
;lob Number:
LQQ93016 - Rev131316 RECEIVED'
DEC 2 3 2016
Date:
CITY of U". OUINTA
..12/21120.16 COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com. `
Energ Pro 6.7 by EnergySoR User Number 5732, - ID: LQ093016 - Rev1313
Cover` Page 1
Table of Contents 2
.Form CF -1R -PRF -01 -E'Certificate.of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1 R Mandatory Measures Summary 14
HVAC System Heating and Cooling Loads Summary 18
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml
CF1 R -PRF -01
Page 1 of 9
GENERAL INFORMATION
01
01
Project Name Staker's Residence
04
02
02
Calculation Description Title 24 Analysis
Ar
03
03
Project Location 54545 Avenida Madero - APIC: 774-261-003
.- 3
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
.07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Pond. Floor Area (ftZ) 2104 '
15
Number of Zones 1
16
Slab Area (ft) 2104
17
Number of Stories 1
18
Addition Cond. Floor Area N/A . "
19
Natural Gas Available No
20
Addition Slab Area (ftZ) I N/A
21
Glazing Percentage (%) 18.7%
COMPLIANCE RESULTS
01
Building Complies with Computer Performances f f -x' ` > t
04
02
This building Incorporates features.that require fieldtesting'and/or.venfication,by a certified HERS rater, un lerthe supervision of a CEC-approved HERS provider.
07
Ar
03
This building incorporates one ormore Special Features shown below f•
Proposed Design
.- 3
Percent Improvement
Registration Number: 216-N0360685B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.36
1.49
0.87
36.9%
Space Cooling
79.96
77.19
2.77
3.5%
IAQ Ventilation
1.08
1.08
0.00
0.0%
Water Heating
29.39
17.72
11.67
39.7%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
112.79
97.48
15.31
13.6%
Registration Number: 216-N0360685B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xm1
REQUIRED SPECIAL FEATURES
TCe following are features tCat must Ce installed as condition For meeting tCe modeled energy performance Cdr tCis computer analysis.
❑ Window overhangs and/or fins
❑ ECposed slab floor in conditioned zone
HERS FEATURE SUMMARY
TCe following is a summary oCtCe features tCat must Ce field -verified Cy a certilied ❑ERS Rater as a condition Cdr meeting tCe modeled energy performance For tEis computer analysis. Additional detail is
provided in tCe Cuilding components taCles Celow.
Building -level Verifications:
❑ IAQ mechanical ventilation
Cooling System Verifications:
❑ Minimum Airflow
❑ Verified EER
❑ Verified SEER
❑ Refrigerant Charge *+
0 Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
❑ Duct Sealing
❑ Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
❑ -- None — qy
P J a e 8 W'
ENERGY DESIGN RATING
TGs is tCe sum oCtCe annual TDO energy consumption [or energy use components'included'in tCeperformance compliance approac❑ Cor tCe Standard Design Building (Energy Budget) and tCe annual
TDO energy consumption for IigCting and components not regulated Cy Title 24; Part'6 (suc❑as domestic appliances and consumes electronics) and accounting for tCe annual TDO energy offset Cy an
on-site renewaCle energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)❑ 167.64 152.33 15.31 9.1%
❑includes calculated Appliances and Miscellaneous Energy ❑se (AME❑)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (f:2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Staker's Residence
2104
1
3
1
0
1
Registration Number: 216-N0360865B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Stalker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 3 of 9
Calculation Description: Title 24 Analysis Input File Name:'54545 Avenida Madero - Staker - Rev121316.xm1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
WEole Douse
Conditioned
❑CAC Systeml
2104
10
DOW Sys 1
Gross Area (ft2)
OPAQUE SURFACES
01
02
03
4i 1� 04
01
02
03
04
05
06
07
08
Name
Zone
Construction
..Azimuth
Orientation
Gross Area (ft2)
Window ❑ Door Area (W)
Tilt (deg)
Ri/N
WCole Douse
R-21 Wall w/1 EPS
0
Rig[t
600
71
.90
Re/W
WCole Douse
R-21 Wall w/1 EPS
270
Back
400
243.401
90
Le/S
WCole Douse
R-21 Wall w/1 EPS
180
Le[tl
760.
22.5
90
Fr/E
WCole Douse "_
R-21 Wall w/1 EPS.
90
Front .,
191.6.
54.9123
90
Roo[2
WCole Douse
R-38 RooCAttic RB
2101.5
OPAQUE SURFACES OCathedral Ceilings,', '�`
01
02
03
4i 1� 04
05 ��
,O6
07
08
09
10
11 .
"Orientatio'`
f #
Skylight Area
Roof Rise--
Roof`
Roof Tilt
Roof
Roof
Framing
Name
Zone...
'�-, TYPe3 .�: �
'7 . n-
�
Area (ft2y
r
"(ft2)', .t -
�
(D'in;12),;,
b`
yP�itch
(deg)
Reflectance
Emittance
..Factor
RooD.
WCole Douse
R-38 RooCAttic R61
RigEt'
2.6 Y
2.5.
0.2
0.02
0.95
0.1
0.85
0.1
ATTIC
01 02 03 04 05 06 J 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic WFole Douse Attic RooLWCole Douse Centilated 0.2 0.1 0.85 Fes No
Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis
Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml
CF1 R -PRF ;01
Page 4of9
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multipli
er
Area
(ft)
U -factor
SHGC
ECterior Shading
5050 13ed3
Window
RUN (Rig[t-0)
----
--
1
25.0
0.30
0.22
[hsect Screen (default)
5016 Bed3 Transom
Window
Ri/N (Rig[t-0)
----
--
1
7.5
0.28
0.25
[hsect Screen (de[ault)
5050 Bed2
Window
Ri/N (Rig[t-0)
----
----
1
25.0
0.30
0.22
[hsect Screen (default)
5016 13ed2 Transom
V\Andow
Ri/N (RigCt-0)
----
---
1
7.5
0.28
0.25
[hsect Screen (de[ault)
4016 Master Bat❑
Window
RUN (RigCt-0)
----
----
1
6.0
0.28
0.25
Cnsect Screen (default)
3080 MBed
Window
Re/W (Back -270)
5.3
1.5
3.048
24.0
0.47
0.24
[hsect Screen (de[ault)
8080 SOD MBed
Wndow
Re/W (Back -270)
----
----
1
64.0
0.47
0.24
I sect Screen (de[-ault)
3080 MBed 2
VNndow
ReM/(Back-270)
5.3
1.5
3.048
24.0
0.47
0.24
insect Screen (de[-ault)
3080 FrDr Living
Window
Re/VV (Back -270)
----
----
1
12.0
0.36
0.35
Cnsect Screen (de[ault)
3016 Living Transom
Window
Re/W (Back -270)
3.0
1.5
1
4.5
0.28
0.22
Cnsect Screen (default)
12280 SOD
Dining/❑itcCen
Window
Re/W (Back -270)
----
----
1
97.3
0.47
0.24
nr sect Screen (default)
51016 Living Transom
Window
Re/W (Back=270) . t"'
�{ 5.8
1.5
11.00.6
�78.8
0.28
0.22
insect Screen (def-ault)
51016 Living Transom
2
Window
t _ 3; { $t,
Re/W (Back -270) x
s
58
11.5
-;
e
x1.006
4.8.8;
0.28
0.22
[-resect Screen (default)
5016 Living Transom
Window
Le/S Le[t-180
( )
-*
--
1 W
7.5
0.28
0.25
[resect Screen (de[ault)
5016 Dining Transom
V\Andow
Le/S (Le[t=180)
---
---
1
7.5
0.28
0.25
[-resect Screen (default)
5016 ❑itcCen Transom
Window
Le/S (Le[t=180)
---
----
1
7.5
0.28
0.25
Cnsect Screen (de[-ault)
5016 Fix Laundry
Window
Fr/E (Front -90)
6.3
2.3
0.527
7.5
0.28
0.22
insect Screen (default)
5016 Fix Laundry 2
V\Andow
Fr/E (Front -90)
6.3
2.3
1.004
14.3
0.28
0.22
[hsect Screen (default) .
3080 FrDr Entry
Window
Fr/E (Front -90)
----
----
1
12.0
0.36
0.35
[hsect Screen (default)
4916 Entry Transom
V\Andow
Fr/E (Front -90)
6.3
2.3
0.499
7.1
0.28
0.22
insect Screen (default)
1980 Entry Sidelite
V\Andow
Fr/E (Front -90)
---
-
1
14.0
0.28
0.22
Chsect Screen (default)
10 SolatuCe 1
SkyligCt
RooC(Rig[t-0)
1
.5
0.61
0.27
10 SolatuCe 2
SkyligCt
RooQRig[t-0)
1
.5
0.61
0.27
10 SolatuCe 3
SkyligCt
Roo[(Rig[t-0)
1
.5
0.61
0.27
10 SolatuCe 4
SkyligCt
RooC(Rig[t-0)
1
.5
0.61
0.27
10 SolatuCe 5
Skylig[t
RooC(RigCt-0)
1
.5
0.61
0.27
Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - U111-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis
Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml
CF1 R -PRF ;01
Page 5of9
OVERHANGS AND FINS
01
02 03 04 05 06
07 08 09 10
11 12 13 14
05 .,
Overhang
Left Fin
Right Fin
Window
Depth
Left
Dist Up ECtent
Right
EF -tent Flap Ht.
Depth
Top Up DistL
Bot Up
Depth Top Up
Dist R Bot Up
3080 MBed
4
1 4
4 0
0
0 0
0
0 0
0 0
3080 MBed 2
4
1 4
4 0
0
0 0
0
0 0
0 0
3016 Living Transom
7.5
1 4
4 0
0
0 0
0
0 0
0 0-
51016 Living Transom
7.5
1 4
4 0
0
0 0
0
0 0
0 0
51016 Living Transom 2
7.5
1 4
4 0
0
0 0
0
0 0
0 0
5016 Fix Laundry
4
0.91 4
4 0
0
0 0
0
0 0
0 0
5016 Fix Laundry 2
4
0.91 4
4 0
0
0 0
0
0 0
0 0
4916 Entry Transom
6.5
1 0.66
0.66 0
0
0 0
0
0 0
0 0
OPAQUE SURFACE CONSTRUCTIONS,
01
02
03 .. w
04
05 .,
06
07
Name
Zone
Area (W)
Perimeter (ft)
Cavity ,
Winter Design
Heated
Construction Name
Surface Type
CoCCnstruction Type:.m�
j Framuig
^¢Total
R -value (
�,U-value
Assembly Layers
•
P ` �
� t=`�'�%`
Cavity /Frame: no insul. / 2x4 Top Chrcl
2x4: Top CCord o Roo -Truss 0 24
1_.. `'-fir
t"
3� �r
Roof Deck: Wood Siding/sheathing/decking
Attic RooLWDole Douse
Attic Roofs
Wood Framed Ceiling-
4r in O.C.
none
0644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Sheathing/ Insulation: R5 Sheathing
• Exterior Finish: Wood
R-21 Wall w/1 EPS
Exterior Walls
Wood Framed Wall
2x6 D 16 in. D.C.
R 21
0.047
Siding/sheathing/decking
• Inside Finish: Gypsum Board
Ceilings (Celow
Cavity/Frame: R-9.1 /2x4
R-38 Roo[Attic RB
attic)
Wbod Framed Ceiling
2x4 0 16 in. D.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 RooCAttic R61
CatCedral Ceilings
Wood Framed Ceiling
2x4 0 16 in. D.C.
R 38
0.041
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (W)
Perimeter (ft)
Edge Insul. R -value 0 Depth
Carpeted Fraction
Heated
Slac-on-Grade
WCole Douse
2104
0.1
None
0
No
Registration Number: 216-N0360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml
BUILDING ENVELOPE - HERS VERIFICATION
01 .02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not ReCuired - Not ReCuired Not Re[Uired ---
CF1 R -PRF ;01
Page 6 of 9
WATER HEATING SYSTEMS
01 02 03 04 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DOWSys 1 - 1/1 DOW Pipe Chsulation, All Lines DOW ❑eater 1 1 .0%
WATER HEATERS
01
02.
03
04
05
06
07
08
❑CAC Fan 1 Air DistriCution System 1
Tank El terior
Tank Volume
Energy Factor or
Central DHW
Insulation
Standby Loss
Name
Heater Element Type :_
Tank Type
(gal)
Efficiency
Input Rating
R -value
(Fraction)
DOW Dealer 1
Propane
Small nr stantaneous,
0
0.84
185000-Btu/Cr
0
0
- k
: ,� . r.R-
o .r: �- et
WATER HEATING - HERS VERIFICATION
01
01
02 » `
'U3 a }_
.N E 04'
Fan Name Distribution Name
06
07
❑CAC Fan 1 Air DistriCution System 1
Recirculation
Central DHW
Name
Pipe Insulation
Parallel Piping
Compact Distribution,
Point -of Use
Control
Distribution
DOWSys 1 - 1/1
---
---
---
SPACE CONDITIONING SYSTEMS
01
02 03 04
05 06
SC Sys Name
System Type Heating Unit Name Cooling Unit Name
Fan Name Distribution Name
Cooling Component 1:❑eating Component 1:Air
DistriElution System 1:❑CAC Fan 1:1
❑tCer Dealing and Cooling Dealing Component 1 Cooling Component 1
System
❑CAC Fan 1 Air DistriCution System 1
HVAC - HEATING UNIT TYPES
01 02 03
Name Type Efficiency
Ceating Component 1 CntrlFurnace - Fuel -tired central Curnace 92 AF❑E
Registration Number: 216-No360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xml
CF1 R -PRF -01
Page 7 of 9
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
14
15
Not Zonal
Single Speed
Cooling Component
1-Cers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-Cers-cool
ReCuired
350
ReCuired
ReCuired
ReCUired
HVAC - DISTRIBUTION SYSTEMS
01
02
03 04
05
06, 07
Name
Type
Duct Leakage Insulation R -value
Duct Location
Bypass Duct HERS Verification
Air DistriCution System 1
DuctsAttic /+."
t «
Specilied Lower,Leakage . r - -- r
�^ Tar et 1 , i 8
t - g. ls�.-.,r:6
Attic
;i' z;*. .x�. � r
Air DistriCution System
None
1-Cers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
€ e w 03�' `
i- 041' ,.-
sa 05 ': �"
t`-`4.06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air DistriCution System 1-7ers-dist
ReCuired
6.0
Not ReCuired
Not ReCuired
Not ReCuired
Not ReCuired
ReCuired
HVAC -FAN SYSTEMS
01 02 03 04
Name Type Fan Power(Watts/CFM) HERS Verification
❑CAC Fan 1 Single Speed PSC Furnace Fan 0.58 ❑CAC Fan 1-Cers-an
HVAC FAN SYSTEMS - HERS VERIFICATION
01 02 03
Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM)
❑CAC Fan 1-Cers-!an ReCuired 0.58
Registration Number: 216-No360885B-000000000-0000 Registration Date/Time: 2016-12-21 01:24:06 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE'- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Stalker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016 Page 8 of 9 .
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316.xm1
IAQ (Indoor Air Quality) FANS
01
02"
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam I-AQCentRpt
51.04
0.25
Default
0
ReCuired
h
Registration Number: 216-N0360885B-000000000-0000
Registration Date/Time: 2016-12-21 01:24:06
HERS Provider: CaICERTS inc.
CA Building Energy. Efficiency Standards - 2013 Residential Compliance
Report Version - CF1R-04072016-744
Report Generated at: 2016-12-2101:09:37
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Staker's Residence Calculation Date/Time: 01:08, Wed, Dec 21, 2016
Calculation Description: Title 24 Analysis Input File Name: 54545 Avenida Madero - Staker - Rev121316:xm1
CFI R -PRF ;Q1 ,
Page 9of9
DOCUMENTATION AUTHORS DECLARATION STATEMENT
1. CcertiCy t[at tEis Certificate oCCompliance documentation is accurate and complete.
Documentation AutCor Name:
Santiago LopeC
Documentation AutCor Signature:
E)campo
Company:
Signature Date:
Santiago LopeE Dcampo
2016-12-21 01:24:06
Address:
CEA/❑ERS Certification I-denti[cation (EapplicaCle):
P.D. Box 1018
na
City/State/Zip:
PCone:
La Quinta, CA 92247
760-485-8927
RESPONSIBLE PERSONS DECLARATION STATEMENT
tCe Collowing under penalty o[periury, under [e laws o[tCe State oLCaliCornia:
_CcertiCy
1. Cam eligiCle under Division 3 oCtCe'Business and Professions Code to accept responsi[ility For tCe CUilding design identified on tCis Certificate oCCompliance.
2. CcertiCy tCat tCe energy features and performance speci[ications identified on tCis Certificate oCCompliance conlorm to Ice recuirements o❑Title 24; Part 1 and Part 6 oCtCe California Code o❑
Regulations.
3. TCe Cuilding design features '& *system design features identified on t[is Certificate oCCompliance are consistent witotCe information provided on otCer applica[le compliance documents, '
worksCeets, calculations, plans and specifications suCrnitted to,tCe enrorcement agency,Jbr approval vAt❑t[is.CUilding permit application.
•Responskle
Responsi[le Designer Name: ;
"
Designer Signature:
,
scoSantiago
Lope ❑Campo _ I `+ ,- .. ::
t
Company:..I'a!
Date.Signed: .�
Santiago LopeC Ocampo
2016-12-21 01:24:06
Address:
License:
'P.D. Box 1018
na
City/State/Zip:
PCone:
La Quinta, CA 92247
760-485-8927
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of.this registered document, and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 216-N0360865B-000000000-oobo Registration Date/Time: 2016-12-21 01:24:06
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744
HERS Provider: CaICERTS inc.
Report Generated at: 2016-12-2101:09:37
RESIDENTIAL MEASURES SUMMARY
RMS -1
Protect Name
StakerFs[Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing ❑Addition/Alteration
Date
12/21/2016
Pro[ect Address
54545[I venida®aderoGFACO.: ®❑4-261-❑
Cali[ornia Energy Climate ZoneTotal
CACClimate®oneC15
Cond. Floor Area
211 E14
Addition
n/a
❑o®nits
1
INSULATION
Construction Type
Area
Cavi (ft) Special Features Status
Sla❑ Dnheated[Sla0•on-Grade
-tihoUbsulationl 2C1D4 ❑erim®®
DeO
Demising Wood[Frramed
R121 341
DeO
Wall Wood[Frramed
R121 11560 Rigid[R-5.0
❑e0
Roof WbodrlFramedFAttic
R[38 2[102
❑e0
FENESTRATION
Orientation Area(ft2)
I Total Area: 394 ❑lacing Percentage: 18•®
U -Fac SHGC Overhang Sidefins
New/Altered Average 0 -Factor: D39
E[terior Shades Status
RightmD) 500
D30D
022 none none
Bug[Screen De❑
Right[60) 21.0
0280
D25 none none
Bug[Screen DeO
Rear((jVlq 48.0
D40D
D24 4.0 none
Bug[Screen De0
Rearr(11M 161.3•
0400
D24 none none
Bug1screen ❑e0
Rearfl604 12.0
D360
D35 none none
Bug[Screen De0
Rear[OK9 22.1
D280
022 05 none
Bug[Screen De0
LOW) 22.5
0280
D25 none none
Bug[Screen DeO
Frontr(E) 21.8
[1280
D22 4.0 none
Bug[Screen De❑
FrontQE) 12.0
0360
035 none none
Bug[Screen ❑eO
Front[QE) D.1
D280
022 6.5 none
Bug[Screen ❑eD
Front[VE) 14.0
D280
022 none none
Bug[Screen ❑e❑
Skylight 05
0610 D20 none none
Done DeO
Skylight D5
0610 0.20 none none
Done De❑
Skylight D5
0610 D20 none none
Done DeO
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
1 CentralrFumace
920 [SIF❑E
Split[Air[Conditioner 15.DESEER
Set❑ack ❑e0
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
0❑AC[System Ducted
Ducted Attic
8.0 ❑e0
WATER HEATING
Qty- Type
Gallons Min. Eff Distribution Status
1 Small[Instantaneous[Gas
0
D84 All®ipesUns
❑e0
Ener-qyDro16.D[fl1y1Ene ySoft DSeraDUmCer[5032
RunCode:2016-12-21T01:16:26
ID:rLDC93D16GrIRev1313 Da eC12[A08
RESIDENTIAL MEASURES SUMMARY
RMS-1
Protect Name
Stakerlg[Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing ❑Addition/Alteration
Date
12/21/2016
Pro(ect Address
54545 1venida®adero2FA❑❑.:�❑4-261-❑
California Energy Climate Zone
CACClimate®oneC15
Total Cond. Floor Area
2[104
Addition❑omnits
n/a
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
FENESTRATION
Orientation Area(ft2)
Total Area: 394 ❑laCing Percentage: 18.7 % New/Altered Average ❑-Factor:
U-Fac SHGC Overhang Sidefins ECterior Shades
0.39
Status
Skylight ❑5
❑610 E12❑ none none Done
❑e❑
Skylight 115
11610 D2❑ none none Done
❑e❑
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty- Type
Gallons Min. Eff Distribution Status
Ene orof6. 0ffjy[EnefgySoft ❑ser00um1er15D32 RunCode:2016-12-21701:16:26 IDADD93❑16GFRev1313
❑a eC13[bA=18
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply ivith all applicable mandaton, measures listed, regardless of the
compliance approach used. Exceptions niay apvly. Review the respective code section for more information.
Building Envelope Measures:
§i 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ i 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a).
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110 8(1):
The thernial enuttance and aged solar reflectance values of the cool roofing material meets the requirements of § i 10.8(i) when the
installation of a cool roof is specified on the CFIR.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have pernianently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§I50.0(d):
Minimum R -i9 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§i50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over tine earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for tine insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 penm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8(g).
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58: or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ 150.0(e) IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to tine outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage comiection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(ln)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE. SMACNA or ACCA using design conditions specified
it § 150.0(h)2.
§ I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thernnal resistance of R-12 or greater.
§150.0(j)IB:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or uiburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.0(j)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class H vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside tennimation and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200.000
Btu/hr.
§ l50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5.
§ I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/n inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ i 50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(nm)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ 150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion filet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ 150.0(m)]0:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)l l:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ l 50.0(m) l 2.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for tine
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§i50.0(m)13:
space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confinned by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control node,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of > 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling umits shall meet time requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 110.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting time thermostat
setting: a permanent weatherproof plate or card with operating instructions: and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
§ 110.4(b)1:
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
granmied to nm only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)lA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ I50.0(k)1 B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with tile applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be detennined in accordance with
§ 150.0(k)I C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§I50.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy lununaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I50.0(k)2E:
No control shall bypass a dimmner or vacancy sensor function if the control is installed to comply with § 150.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ i 50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in § 150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § i 50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in § 150.0(k)2.
§150.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to §110.9, and complies with all other applicable requirements in §150.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy lununaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy. or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory, have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk, and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting pernianently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astrononnical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4, meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically tum the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with § 150.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, §140.7 and § 141.0.
§ I50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ I50.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9, § l 30.0, § 130. 1, § 130.4, `140.6, and § 141.0.
In a low-rise multifannily residential building where the total interior commion area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of tine floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
n. Comply with the applicable requirements in § 110.9, § 130.0, § 130.1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fiilly Om and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.10(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of § 110.10(b) through § l 10.10(e).
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ 110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§1 10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the infornnation from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§I 10.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ l 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and pernianently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Staker's Residence
12/21/2016
System Name
Floor Area
HVAC System
2,104
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,135
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 80,000
23,385
2,522
414
16,151
Total Output (Btuh) 80,000
0
Output(Btuh/sgft) 38.0
1,350
794
Cooling System
0
0
Output per System 59,500
0
0 0
0
Total Output (Btuh) 59,500
0
2,522
0
Total Output (Tons) 5.0
1,350
794
Total Output (Btuh/sgft) 28.3
Total Output (s ft/Ton) 424.3
1 26,085
17,738
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
York H4TS060S06
41,033 9,393
80,000
Airflow (cfm/sgft) 0.95
Airflow (cfm/Ton)
403.4
80,000
Jan 1 AM
Outside Air (%) 1 0-0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
41,0331 9,393
Aug 3 PM
Outside Air (cfm/sgft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures. at Time of Heating Peak)
26 OF 68 OF
68 OF
105 OF
Outside Air»
-
0 cfm Supply Fan
Heating Coil
105 OF
2,000 dm
-- -.- --
ROOM
68 OF
68 OF
dog
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F 76!62°F 76162°F 55/54°F
Outside Air
I
:.. ..... ..-.
0 cfm
Supply Fan
Cooling Coil
56 / 54 OF
2,000 cfm
47.6% ROOM
i
76 ! 62 OF
75 / 62 OF
EnergyPro 6.7 by EnergySoff User Number. 5732 RunCode: 2016-12-21T01:16:26