BRES2017-0119, VOICE (760) 777-7125
78-495 CALLE TAMPICO � C` 0 D
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN &DEVELOPMENT DEPARTMENT FAX
(760) 777-7153
BUILDING PERMIT
® Date: 8/3/2017
Application Number: BRES2017-0119 ® Owner:
Property Address: 51080 MARBELLA CT OLLIN & MIKE BELLOTTI
APN: 777320009 //)� aa 1080 MARBfELLA CT
Application Description: BELLOTTI / 197SF ADDITION WI GARAGE ORR AREe PN QUINTA, CA 92253
Property Zoning:
Application Valuation: $22,000.00DESIGNgNDDEEPo MQUINTA
Applicant: ENT DEPARTA4ENT Contractor:
GLS ARCHITECHTURE GROUP NICOL CONSTRUCTION INC DBA NICOL CLIMATE
74991JONI DR #9 67851 OCOTILLO TRAIL
PALM DESERT, CA 92,260 DESERT HOT SPRINGS, CA 92241
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: Qk C20 License No.: 878070
c'
Date: Contzironw_c:P �
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the4
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
(760)567-2811
Llc: No.: 878000
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certif Cate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain worker' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insumance carrier and policy number are:
Carrier: WESCO INSURANCE COMPANY Policy Number: WWC3242024
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply w'th tose provisions.
Die: --V _ Applicant: w/
WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRI MINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($10C,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED =OR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACK dOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless -he City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this apolication becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-ment' ned roperty for inspection purposes.
Dat ..� Signature (A I' or Agent):
' ?
Date: 8/3/2017
Application Number: BRES2017-0119
Owner:
Property Address: 51080 MARBELLA CT
COLLIN & MIKE BELLOTTI
APN: 777320009
51080 MARBELLA.CT
Application Description: BELLOTTI / 197SF ADDITION WITH GARAGE PORTAL ALTERATION
LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $22,000.00
Applicant:
Contractor:
GLS ARCHITECHTURE GROUP
NICOL CONSTRUCTION INC DBA NICOL CLIMATE
74991JONI DR #t9
67851 OCOTILLO TRAIL
PALM DESERT, CA 92260
DESERT HOT SPRINGS, CA 92241
(760)567-2811
---------------------------------------------------------------------------------------------
Llc. No.: 878070
Detail: 197SF BATHROOM AND LIVING AREA ADDITION WITH ALTERATION TO GARAGE PORTAL TO
MAKE SINGLE OPENING [ENGINEERED] THIS PERMIT
DOES NOT INCLUDE BLOCK WALLS'OR OTHER SITE IMPROVEMENTS. 2016 CALIFORNIA BUILDING
CODES.
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$65.36
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.24
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$127.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$179.36
Total Paid for ADDITION: $390.64
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT .
QTY.
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
1
$95.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
0.5
$47.50
Total Paid for BLDG CITY STAFF - PER HOUR: $162.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$152.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$50.16
Total Paid for ELECTRICAL - NEW CONS—.RUCTION: $202.16
DESCRIPTION
ACCOUNT
QTY
AMOUNT
OTHER MECHANICAL EQUIPMENT
101-0000-42402
0
$38.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
OTHER MECHANICAL EQUIPMENT PC
101-0000-42600
0
$38.00
Total Paid for MECHANICAL: $76.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$38.01
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$12.67
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.67
Total Paid for PLUMBING FEES: $101.36
n
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-2 0308
0
$2.86
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.86
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
TOTALS: $941.52
I
I
Bin A _
A
uri -v Q 1
City of La Quint'a
Building 8t' Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
�j
Project Address: 0
Owner's Name:
A. P: Number:
2_0
D
Address: 51.
Legal Description: 54q IQ3
T 3 15-19 tot Y)'City,
ST, Zip: ��CA 3
Contractor:
r
v
—Telephone:
Address: 8
O
Project Description:
City, ST, Zip:
C
Telephone: hone:
7&01S
U
State Lic. # :
Arch., Engr., Designer: �LS
City Lic. #: Q/O 17-6
,
W L
Address: 7
Jot4l
City, ST, Zip:
C �'qz�z 6110
Tele hone:
State Lic. #:
Construction n Type: e: V Occupancy:
ro'e
Project i
(circle one New Add n t
J type Alter Repair Demo
Name of Contact Person:
Sq. Ft: j q 7
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project: , 2z"00 v
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
Zed Review, ready for corrections/issue
Electrical
Subcontactor. List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A: Approval.
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
I COMMAND. AMOUNT:
DATE:
RECEIPT:
CFECK #: -
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Mountain View Country Club, Date: July 31, 2017
Owner's Name: Collin & Mile Bellotti Phoae No.
Project Address: 51-080 Marbella Ct., LaQuinta
Project Description: Addition
760-218-6909
APN:, . 777-320-009 Tract #: Lot #'s:
Type of Development: Residential XX! Commercial Industrial
Total Square Feet of Building Area: 197
Certification of Applicant/Owners: The person signing certifies that the above information is conect and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign o". alf of the owner/dev✓loper.
Dated: July 31, 2017 . Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code, Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Note:
Number of Sq.Ft. 197 Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
Amount per Sq.Ft. $0.00 homes being relocated within .he same school district's
Amount Collected $0.00 jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and Maintenance
Certificate issued by: Laurie Howard, Secretary Signature:0`-d
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as 1.erein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts o:o the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as delermined by the School District, and up
to three (3) such extensions may be granted.
MV:elmydocs%devi'ecs.Icertificate of compliance form updated 3-2007 11/2010
DESIGN & DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7125 FAX (760) 777-7011
CERTIFICATION OF BUILDING AREA
STREET ADDRESS OF JOB: 51-080 MARBELLA CT
APN: 777 - 320 - 009
DESCRIPTION OF WORK: ADDITION
SQUARE FOOTAGE: 197
OWNER'S NAME: COLLIN & MIKE BELLOTTI
0
For questions regarding this letter, please contact:
City of La Quints Permit Center
(760) 777=7125
Coachella Valley Unified School District.
83-733 Avenue 55
P 0 Box 847
Thermal, CA 92274
(760) 398-5909
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
CITY OF LA QUINTA
BUILDING DIVISION '
APPROVED
FOR CONSTRUCTION
BY: A. DATE: 07/12/2017
Please note: This letter verifies conditioned square footage. Please call your
School District to verify school fees, requirement for cashier's check or money
order and hours of operation.
Building Permit Number:
Project Description: small room addition
Exempt: 0
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E -Mail Address
Project Manager's Name!,
Project Manager's Phone Number
Project Manager's E-mail Address)
Builder / Contractor)
Number, Street or PO Box
City, State, Postal Code'
Project Square Footage
City Approval By
Date of City Approval
Materials To Be Discarded:
Product Tons
0.90 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
10.00
Recyclable
RecyclableRecyclable
8/1/2017
51080 Marvella Ct
Mike & Coleen Belotti
51080 Marvella Ct
La Quinta, CA. 92253
541-912-5704
Ricardo Linares
760-218-6909
ricardlinares.caoba(a)yahoo.com
Nicol Construction
67677 Long Canyon Rd
Desert Hot Springs, CA. 92242
192 square feet
Renado Gouldlock-DEC/Burrtec Waste
OFS& 1I 7
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse"
"Describe Items
Totals: Rec cle Trash
1.7 10.9
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
0.24 Recyclable
0.00 Recyclable
0.02 Recyclable
0.03 Recyclable
0.36 Recyclable
0.00 Recyclable
Projected Diversion:
65.38%
1 understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation anc adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jotsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -:use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the constrjction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner / Developer / Project Manager / Superintendant
Date
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017
- Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribdl6x
CF1 R -PRF -01
Page 1 of 10
GENERAL INFORMATION
ENERGY USE SUMMARY
01
Project Name BELLOTTI RESIDENCE
06
07
08
Energy Use (kTDV/ftZ-yr)
02
Calculation Description Title 24 Analysis
Compliance Margin
Percent Improvement
Space Heating
4.20
03
Project Location 51080 MARBELLA CT.
22.9%
Space Cooling
250.64
241.51
04
City LA QUINTA
05
Standards Version Compliance 2017
0.00
06
Zip Code 92253
07
Compliance Manager Version
BEMCmpMgr 2016.2.1 (695)
08
Climate Zone CZ15
09
Software Version
CBECC
0.00
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 45 ee
W.rh
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units
1 fL
14
Total Cond. Floor Area (ftZ) 4162
15
Number of Zones
2
U O
16
Slab Area (ft2) 4162
17
Number of Stories
1
18
Addition Cond. Floor Area 193
19
Natural Gas Available
Yes LJ
...
20 71
Addition Slab Area (ftZ) 193
21
Glazing Percentage (%)
19.2% 2
Pit
(J) m
COMPLIANCE RESULTS C7 0..r I
01 Building Complies with Computer PerformanceeP _ h r:=,
02 This building incorporates features:.that require fieldaesting and/or,ver�ficat`ionFby a certified HERS pater urider the supervision of a CEC- p rovid r.
03 This building incorporates one.or•'more Special'Features shown "tielow'�j0 m f'
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer anal i
• Window overhangs and/or fins
CITY OF LA QUINTA
PLANNING DEPARTMENT
atlon Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
- CA ilding Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.20
3.24
0.96
22.9%
Space Cooling
250.64
241.51
9.13
3.6%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
5.67
5.67
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
260.51
250.42 or.
W.rh
3.9%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer anal i
• Window overhangs and/or fins
CITY OF LA QUINTA
PLANNING DEPARTMENT
atlon Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
- CA ilding Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CFI R -PRF -01
Page 2 of 10
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Insulation Inspection
Cooling System Verifications:
9 .. Nnno ..
HVAC Distribution System Verifications:
--None --
Domestic Hot Water System Verifications:
--None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
BELLOTTI RESIDENCE
4162
1
3
2
0
1
ZONE INFORMATION
01
02
F03;+�:' rC_71 M
04�
n 05
06
07
Zone Name
Zone Type°
s --HVAC System Named
" Zone FloZor,Area
(ft )_ ; r
#f ` °
Avg• Ceiling,
Height �;
i.pater Heating System 1
Water Heating System 2
(E) 3969
Conditioned `
&A r.(E)iHVAC1
X3969 7- #
10
DHW Sys 1
n/a
(N) 193
Conditioned(E)FHVACI
193 M
8�
DHW Sys 1
n/a
Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CFI R -PRF -01
Page 3 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door
Area (ft)
Tilt
(deg)
Status
Verified
Existing
Condition
NW- 640
(E) 3969
Default Wall 1992 to Pres
315
Right
640
269.656
90
Existing
No
NE - 928
(E) 3969
Default Wall 1992 to Pres
45
Front
928
67.862
90
Existing
No
SE- 781
(E) 3969
Default Wall 1992 to Pres
135
Left
781
320
90
Existing
No
SW - 928
(E) 3969
Default Wall 1992 to Pres
225
Back
928
162.51
90
Existing
No
3969
(E) 3969
Def Roof '78 to Present
3969
Existing
No
NW- 137
(N) 193
R-15 Wall
315
Right
137
0
90
New
N/A
NE - 115
(N) 193
R-19 Wall
45
Front
115
24
90
New
N/A
SE- 31
(N) 193
R-15 Wall
135
Left
48
0
90
New
N/A
SW - 115
(N) 193
R-15 Wall
225
Back
48
F 0
90
New
N/A
OPAQUE SURFACES — Cathedral Ceilings '
01
02
03 o�;:
„04
05�
�06
07
0fl
08
09
10
11
12
13
Name
Zone
Type
,�
.Otientatiofe
,n,
(ft2)
�.
Skylights.
A ea (ft2)(x
Uloof-.Rise,,
m12)j.
g Roof
`� Pitch r
Roof*
Tilt(deg)�
Roof
Reflectan
ce
Roof
Emittance
Framin
g
Factor
Status
Verified
Existing
Condifion
193
(N) 193
Cathedral
specify -
193
0
0.2
0.02
0.95
0.1
0.85
0.1
New
N/A
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic (E) 3969
Attic Roof(E) 3969
Ventilated
5
0.1
0.85
No
No
Existing
No
Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CF1 R -PRF -01
Page 4 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth) Width(ft)
Height (ft)
Multiplier
Area (ft)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
4060
NW- 640 (Right -315)
4.0
6.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
1470
NW- 640 (Right -315)
1.3
7.0
8.791
80.0
0.71
0.73
Insect Screen (default)
Existing
No
14702
NW- 640 (Right -315)
1.3
7.0
8.791
80.0
0.71
0.73
Insect Screen (default)
Existing
No
3060
NW- 640 (Right -315)
3.0
6.0
1
18.0
0.71
0.73
Insect Screen (default)
Existing
No
30602
NW- 640 (Right -315)
3.0
6.0
1
18.0
0.71
0.73
Insect Screen (default)
Existing
No
1420
NW- 640 (Right -315)
1.3
2.0
1.023
2.7
0.71
0.73
Insect Screen (default)
Existing
No
2040
NE - 928 (Front -45)
2.0
4.0
1
8.0
0.71
0.73
Insect Screen (default)
Existing
No
4456
NE - 928 (Front -45)
2.0
4.0
2.139
17.1
0.71
0.73
Insect Screen (default)
Existing
No
1616
NE - 928 (Front -45)
1.5
1.5
1
2.3
0.71
0.73
Insect Screen (default)
Existing
No
16162
NE - 928 (Front -45)
1.5
1.5
1
2.3
0.71
0.73
Insect Screen (default)
Existing
No
16163
NE - 928 (Front -45)
,- 1.5;1
- 1.5-
� q1 y _
� ,.2.3
y0.71
0.73
Insect Screen (default)
Existing
No
6060
NE - 928 (Front -45)
lfrf X6.0;
6.6t-
1 F
'%36.0
16.71 } 0 737
Insect Screen (default)
Existing
No
60602
SE- 781 -(Left -`135)36.0
0.71'
10,
Insect Screen (default)
Insect
Existing
No
60603
SE- 781 (L'eft-135)
i-6.0P""�r
x»6.0 f t.-1_ �.� x;36:0
X0.71
0:73
Insect Screen (default)
Existing
No
8080
SE- 781 (Left -135)
` '8.0 '
""'8.0
1' 64.0 `
.71
0.73
Insect Screen (default)
Existing
No
80802
SE- 781 (Left -135)
8.0
8.0
1
64.0
0.71
0.73
Insect Screen (default)
Existing
No
60604
SE- 781 (Left -135)
6.0
6.0
1
36.0
0.71
0.73
Insect Screen (default)
Existing
No
60605
SE- 781 (Left -135)
6.0
6.0
1
36.0
0.71
0.73
Insect Screen (default)
Existing
No
6080
SE- 781 (Left -135)
6.0
8.0
1
48.0
0.71
0.73
Insect Screen (default)
Existing
No
60802
SW - 928 (Back -225)
6.0
8.0
1
48.0
0.71
0.73
Insect Screen (default)
Existing
No
40602
SW - 928 (Back -225)
4.0
6.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
40603
SW - 928 (Back -225)
4.0
6.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
6050
SW - 928 (Back -225)
6.0
5.0
1
30.0
0.71
0.73
Insect Screen (default)
Existing
No
2650
SW - 928 (Back -225)
6.0
5.0
0.417
12.5
0.71
0.73
Insect Screen (default)
Existing
No
40604
SW - 928 (Back -225)
4.0
6.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
40605
NE - 115 (Front -45)
-
---
1
24.0
0.40
0.35
Insect Screen (default)
New
N/A
Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration DateMme: HERS Provider: CaICERTS inc.
- CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Page 5 of 10
Calculation Description: Title 24 Analysis. Input File Name: 2R-030 - 51080 MARBELLA'CT..ribd16x `
3
OPAQUE DOORS
" 01
02
03
04
05
06
Name -
Side of Building
Area (ft2)
U -factor
Status
Verified Existing Condition
- 2868
NW- 640
19.0
0.50
Existing
y No
3680
NW- 640
28.0
0.50
Existing
No
"H ERS PROVIDE
-.. V i
Registration Number:217-P010162784C-000-000-0000000-0000 Registration DateRme: - HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 ' . Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CF1 R -PRF -01
Page 6 of 10
OVERHANGS AND FINS
01
02
03
04
05 06
07
0809
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up
Dist R
Bot Up
4nRn
8
n 1
R
A n
n
n
n
n
0
0
0
0
1470
10
0.1
10
10 0
0
0
0
0
0
0
0
0
14702
10
0.1
10
10 0
0
0
0
0
0
0
0
0
3060
2
0.1
2
2 0
0
0
0
0
0
0
0
0
30602
2
0.1
2
2 0
0
0
0
0
0
0
0
0
1420
2
0.1
2
2 0
0
0
0
0
0
0
0
0
2040
2
0.1
2
2 0
0
0
0
0
0
0
0
0
4456
2
0.1
2
2 0
0
0
0
0
0
0
0
0
1616
2
0.1
2
2 0
0
0
0
0
0
0
0
0
16162
2
0.1
2
2 0
0
0
0
0
0
0
0
0
16163
2
0.1
�=2
n2F j—{"-'�.- 0'
=7! 0
on
0
0
0
0
0
0
6060
60602
2
2
n 0.1
<,` 0.1
2 D'
2',,l ;
I f 2 � Q� `"-
U' 2" � 6J �,
0 `
�� 0 ct:'i
0 $
OU C
t Q
U 0 0
0
0
0
0
0
0
0
0
0
0
6060 3
2
""o''1
.. 2 F
2 j7U5 R
r
_ 1, 07)
F 0►
0
0
0
0
0
8080
10
0.1
10
10 0
0
0
0
0
0
0
0
0
80802
10
0.1
10
10 0
0
0
0
0
0
0
0
0
60604
2
0.1
2
2 0
0
0
0
0
0
0
0
0
60605
2
0.1
2
2 0
0
0
0
0
0
0
0
0
6080
10
0.1
10
10 0
0
0
0
0
0
0
0
0
60802
10
0.1
10
10 0
0
0
0
0
0
0
0
0
40602
2
0.1
2
2 0
0
0
0
0
0
0
0
0
40603
2
0.1
2
2 0
0
0
0
0
0
0
0
0
6050
2
0.1
2
2 0
0
0
0
0
0
0
0
0
2650
2
0.1
2
2 0
0
0
0
0
0
0
0
0
40604
10
0.1
10
10 0
0
0
0
0
0
0
0
0
-Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Dateffime: HERS Provider: CaICERTS inc.
. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CF1 R -PRF -01
Page 7 of 10
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
1 0.1
None
0.8
No
Existing
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
(N) 193
193
0.1
2x4 Top Chord of Roof Truss @ 24
0
No
Roof Deck: Wood Siding/sheathing/decking
Attic Roof(E) 3969
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Def Roof '78 to Present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 21
0.045
Over Ceiling Joists: R-11.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
Default Wall 1992 to Pres
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.101
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Sheathing/ Insulation: R5 Sheathing
• Cavity / Frame: R-21 / 2x8
• Roof Deck: Wood Siding/sheathing/decking
R-21 Roof Cathedral
Cathedral Ceilings
Wood Framed Ceiling
2x8 @ 16 in. O.C.
R 21
0.039
Roofing: Light Roof (Asphalt Shingle)
(
00C.
095
• Inside Finish: Gypsum Board
Cavity / Frame: R-15 / 2x4
R-15 Wall
Exterior Walls
Wood Framed Wal D
2x4:@ 16
R 15q
')_� (,0
Exterior Finish: 3 Coat Stucco
U U
0
Inside Finish: Gypsum Board
R-19 Wall
Exterior Walls
Wood Framed -Wall �"'�
6 @ 1 �. . OC
R 19
�U_
� 0 072
Cavity / Frame: R-19 / 2x6
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
39692
(E) 3969
1 3969
1 0.1
None
0.8
No
Existing
No
1932
(N) 193
193
0.1
None
0
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required ---
-Registration Number: 217-P010162784C-000-000-0000000-0000 Registration DateMme: HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribdl6x
CFI R -PRF -01
Page 8 of 10
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Name
Heater
Element Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Energy
Factor or
Efficiency
Input
Rating/Pilot
Tank Insulation
R -value
(Int/Ext)
Standby Loss /
Recovery Eff
NEEA Heat Pump Type
Tank Location or
Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
1 0.575 EF
1 40000 Btu/hr
I n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
09
10
Heating System
Cooling System
Insulation
Supply Duct
Return Duct
Name
System Type
Name
Ducted
�
! [ Name
^-- -�
Ducfed
Distribution
System
Fan
teT_—
Floor Area
;; Served
Status
Verified Existing
Condition
(E) HVAC1
Other Heating and
Cooling System
Heatingt
+
Component +1--�
Yes
Cooling'
"Component 1-
N
3 Yes
Air Distribution,
* k rr
`System 1
€HVAC Fan
4162
Existing
No
HVAC - DISTRIBUTION SYSTEMS '"' "" "" 4..�* CA
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
(Ventilated and
Existing (not
6.0
Attic
Attic
None
Existing
No
N/A
System 1
Unventilated)
specified)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
-Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
-,CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
I
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01
Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Page 9 of 10
Calculation Description: Title 24 Analysis r Input File Name:.2R-030 =51080 MARBELLA CT,.ribd16x
1 -
�'O�*RTS
)C.' C Crk nc.
HE R,5 P R 0
• . v - - � i .. } •• -' - - �, .., .i . -t . • _,. _ - moi. ,g .
-Registration Number: 217-Po101627e4C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc.
.-.CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version"- CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: BELLOTTI RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 10:09, Thu, Jun 22, 2017
Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x
CF1 R -PRF -01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: — .-
ARMANDO CHAVEZ
Company:
Signature Date:
TITLE 24 OF THE DESERT
Address:
CEA/HERS Certification Identification (If applicable):
74800 Shirley #62
N.A.
City/State/Zip:
Phone:
PALM DESERT, CA 92260
760-278-1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this'Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement.agencyforapproval:with,this<building permit application.
>'
Responsible Designer Name:
1(Lit
s'
Responsible Designer Signature: t
Rub en RomeroLr0'
Company:Date
H E S
Signed -
GLS ARCHITECTURE GROUP INC
Address:
License:
74491 JONI DR SUITE #9
N.A.
City/State/Zip:
Phone:
P760-340-3528
Palm Desert, CA 92260
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
_Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Date/Time:
-,,CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695
r .
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2017-06-22 10:10:39
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
BELLOTII RESIDENCE'S addition
Building Type
0 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
6/22/2017
Project Address
51080 MARBELLA CT. LA QUINTA
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,162
Addition
193
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
Slab Unheated Slab -on -Grade - no insulation
3,969 Perim = 0'
Existing
Roof Wood Framed Attic R 21
3,969
Existing
Wall Wood Framed R 13
2,457
Existing
Door Opaque Door - no insulation
47
Existing
Roof Wood Framed Rafter R 21
193 Add=R-5.0
New
Slab Unheated Slab -on -Grade - no insulation
193 Perim = 0'
New
Wall Wood Framed R 15
323
New
Wall Wood Framed R 19
91
New
FENESTRATION I Total Area: 797 Glazing Percentage: 19.1%1New/Altered Average U -Factor:
Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades
0.40
Status
Right (NM 24.0 0.710
0.73 8.0
none Bug Screen
Existing
Right (NW) 160.0 0.710
0.73 10.0
none Bug Screen
Existing
Right (NIA 38.7 0.710
0.73 2.0
none Bug Screen
Existing
Front (NE) 67.9 0.710
0.73 2.0
none Bug Screen
Existing
Left (SE) 144.0 0.710
0.73 2.0
none Bug Screen
Existing
Left (SE) 176.0 0.710
0.73 10.0
none Bug Screen
Existing
Rear (SW) 72.0 0.710
0.73 10.0
none Bug Screen
Existing
Rear (SKO 90.5 0.710
0.73 2.0
none Bug Screen
Existing
Front (NE) 24.0 0.400
0.35 none
none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat
Status
3 Central Furnace 75% AFUE
Split Air Conditioner 8.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R -Value
Status
(E) HVAC Ducted
Ducted
Attic 6.0
Existing
WATER HEATING
Qty- Type Gallons Min. Eff Distribution
Status
EnerqvPro 7.1 by Ener Soft User Number: 20648
ID: 17 -GLS -030-2R
Pae 13 of 17
2016 Low -Rise Residential Mandatory Measures Summary
s
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply. '
Building Envelope Measures:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
§ 110.6(a)1'
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/l.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). '
Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES
§ 110.6(b)::
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
asketed, or weather stripped.
§ 110.8(a): s
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
§ 110.8(1):
material must meet the requirements of 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.80):.
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.'
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average LI -factor must not exceed 0.043.
Minimum R-19 or weighted average LI -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U -factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.'
§ 150.0(f):
Slab Edge Insulation: Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
1
§ 150.0(g)l:
150.0
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum LI -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures: -
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'•
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.* .
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
-§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pitot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool ands a heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
F1
2016 Low -Rise Residential Mandatory Measures Summary
•T
J i.
dryer vent.
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
§ 150.0(h)3A:
dryer vent.
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
§ 150.0(h)3B:
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; '
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.0(j)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:�
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)l :
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr:
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5:
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a •
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. .
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that'
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tae is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)g:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:.
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
' 2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts tc supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed s-.atic pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nomi ial cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic, testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and eery zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard E2.2. Neither window operation nor
§150.0(0):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)lA:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RAU.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater teat allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)l:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the lifter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix he pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specked requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires nust meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 1 50.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)lA:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served b� a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings;
§ 150.0(k)l D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Nght lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)l F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the mansfacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)l G:
with Reference Joint Appendix JA8. Installed lamps must be marked with °JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)l H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must he marked with °JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that pernit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufadlurer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the cootrol is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 1'0.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; rreets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements h § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(f); and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dinmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
4. IQ 2016 Low -Rise Residential Mandatory Measures Summary
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
§ 150.0(k)2J:
be controlled by a vacancy sensor.
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
§ 150.0(k)2K:
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3A:
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
§ 150.0(k)3C:
150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in 110.9, 130.0,130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
§ 150.0(k)3D:
vehicles per site must comply with thea licable requirements in 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
§ 150.0(k)4:
ower as determined according to § 130.0(c).
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
§ 150.0(k)5:
applicable requirements for nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane."
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".