Loading...
BRES2017-0119, VOICE (760) 777-7125 78-495 CALLE TAMPICO � C` 0 D LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN &DEVELOPMENT DEPARTMENT FAX (760) 777-7153 BUILDING PERMIT ® Date: 8/3/2017 Application Number: BRES2017-0119 ® Owner: Property Address: 51080 MARBELLA CT OLLIN & MIKE BELLOTTI APN: 777320009 //)� aa 1080 MARBfELLA CT Application Description: BELLOTTI / 197SF ADDITION WI GARAGE ORR AREe PN QUINTA, CA 92253 Property Zoning: Application Valuation: $22,000.00DESIGNgNDDEEPo MQUINTA Applicant: ENT DEPARTA4ENT Contractor: GLS ARCHITECHTURE GROUP NICOL CONSTRUCTION INC DBA NICOL CLIMATE 74991JONI DR #9 67851 OCOTILLO TRAIL PALM DESERT, CA 92,260 DESERT HOT SPRINGS, CA 92241 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: Qk C20 License No.: 878070 c' Date: Contzironw_c:P � OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the4 basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's (760)567-2811 Llc: No.: 878000 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certif Cate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain worker' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insumance carrier and policy number are: Carrier: WESCO INSURANCE COMPANY Policy Number: WWC3242024 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply w'th tose provisions. Die: --V _ Applicant: w/ WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI MINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($10C,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED =OR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACK dOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless -he City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this apolication becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-ment' ned roperty for inspection purposes. Dat ..� Signature (A I' or Agent): ' ? Date: 8/3/2017 Application Number: BRES2017-0119 Owner: Property Address: 51080 MARBELLA CT COLLIN & MIKE BELLOTTI APN: 777320009 51080 MARBELLA.CT Application Description: BELLOTTI / 197SF ADDITION WITH GARAGE PORTAL ALTERATION LA QUINTA, CA 92253 Property Zoning: Application Valuation: $22,000.00 Applicant: Contractor: GLS ARCHITECHTURE GROUP NICOL CONSTRUCTION INC DBA NICOL CLIMATE 74991JONI DR #t9 67851 OCOTILLO TRAIL PALM DESERT, CA 92260 DESERT HOT SPRINGS, CA 92241 (760)567-2811 --------------------------------------------------------------------------------------------- Llc. No.: 878070 Detail: 197SF BATHROOM AND LIVING AREA ADDITION WITH ALTERATION TO GARAGE PORTAL TO MAKE SINGLE OPENING [ENGINEERED] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS'OR OTHER SITE IMPROVEMENTS. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $65.36 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $18.24 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $179.36 Total Paid for ADDITION: $390.64 DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT . QTY. AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 $95.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 0.5 $47.50 Total Paid for BLDG CITY STAFF - PER HOUR: $162.50 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONS—.RUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $38.00 Total Paid for MECHANICAL: $76.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $38.01 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.67 Total Paid for PLUMBING FEES: $101.36 n DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-2 0308 0 $2.86 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.86 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: $941.52 I I Bin A _ A uri -v Q 1 City of La Quint'a Building 8t' Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �j Project Address: 0 Owner's Name: A. P: Number: 2_0 D Address: 51. Legal Description: 54q IQ3 T 3 15-19 tot Y)'City, ST, Zip: ��CA 3 Contractor: r v —Telephone: Address: 8 O Project Description: City, ST, Zip: C Telephone: hone: 7&01S U State Lic. # : Arch., Engr., Designer: �LS City Lic. #: Q/O 17-6 , W L Address: 7 Jot4l City, ST, Zip: C �'qz�z 6110 Tele hone: State Lic. #: Construction n Type: e: V Occupancy: ro'e Project i (circle one New Add n t J type Alter Repair Demo Name of Contact Person: Sq. Ft: j q 7 # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: , 2z"00 v APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan Zed Review, ready for corrections/issue Electrical Subcontactor. List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A: Approval. Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees CITY OF LA QUINTA COMMUNITY DEVELOPMENT Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: I COMMAND. AMOUNT: DATE: RECEIPT: CFECK #: - INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Mountain View Country Club, Date: July 31, 2017 Owner's Name: Collin & Mile Bellotti Phoae No. Project Address: 51-080 Marbella Ct., LaQuinta Project Description: Addition 760-218-6909 APN:, . 777-320-009 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 197 Certification of Applicant/Owners: The person signing certifies that the above information is conect and makes this statement under penalty of perjury and further represents that he/she is authorized to sign o". alf of the owner/dev✓loper. Dated: July 31, 2017 . Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code, Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Note: Number of Sq.Ft. 197 Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile Amount per Sq.Ft. $0.00 homes being relocated within .he same school district's Amount Collected $0.00 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature:0`-d NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as 1.erein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts o:o the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as delermined by the School District, and up to three (3) such extensions may be granted. MV:elmydocs%devi'ecs.Icertificate of compliance form updated 3-2007 11/2010 DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB: 51-080 MARBELLA CT APN: 777 - 320 - 009 DESCRIPTION OF WORK: ADDITION SQUARE FOOTAGE: 197 OWNER'S NAME: COLLIN & MIKE BELLOTTI 0 For questions regarding this letter, please contact: City of La Quints Permit Center (760) 777=7125 Coachella Valley Unified School District. 83-733 Avenue 55 P 0 Box 847 Thermal, CA 92274 (760) 398-5909 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 CITY OF LA QUINTA BUILDING DIVISION ' APPROVED FOR CONSTRUCTION BY: A. DATE: 07/12/2017 Please note: This letter verifies conditioned square footage. Please call your School District to verify school fees, requirement for cashier's check or money order and hours of operation. Building Permit Number: Project Description: small room addition Exempt: 0 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E -Mail Address Project Manager's Name!, Project Manager's Phone Number Project Manager's E-mail Address) Builder / Contractor) Number, Street or PO Box City, State, Postal Code' Project Square Footage City Approval By Date of City Approval Materials To Be Discarded: Product Tons 0.90 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 10.00 Recyclable RecyclableRecyclable 8/1/2017 51080 Marvella Ct Mike & Coleen Belotti 51080 Marvella Ct La Quinta, CA. 92253 541-912-5704 Ricardo Linares 760-218-6909 ricardlinares.caoba(a)yahoo.com Nicol Construction 67677 Long Canyon Rd Desert Hot Springs, CA. 92242 192 square feet Renado Gouldlock-DEC/Burrtec Waste OFS& 1I 7 Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse" "Describe Items Totals: Rec cle Trash 1.7 10.9 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons 0.00 Recyclable 0.24 Recyclable 0.00 Recyclable 0.02 Recyclable 0.03 Recyclable 0.36 Recyclable 0.00 Recyclable Projected Diversion: 65.38% 1 understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation anc adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jotsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -:use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the constrjction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager / Superintendant Date CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 - Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribdl6x CF1 R -PRF -01 Page 1 of 10 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name BELLOTTI RESIDENCE 06 07 08 Energy Use (kTDV/ftZ-yr) 02 Calculation Description Title 24 Analysis Compliance Margin Percent Improvement Space Heating 4.20 03 Project Location 51080 MARBELLA CT. 22.9% Space Cooling 250.64 241.51 04 City LA QUINTA 05 Standards Version Compliance 2017 0.00 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version CBECC 0.00 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 45 ee W.rh 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 fL 14 Total Cond. Floor Area (ftZ) 4162 15 Number of Zones 2 U O 16 Slab Area (ft2) 4162 17 Number of Stories 1 18 Addition Cond. Floor Area 193 19 Natural Gas Available Yes LJ ... 20 71 Addition Slab Area (ftZ) 193 21 Glazing Percentage (%) 19.2% 2 Pit (J) m COMPLIANCE RESULTS C7 0..r I 01 Building Complies with Computer PerformanceeP _ h r:=, 02 This building incorporates features:.that require fieldaesting and/or,ver�ficat`ionFby a certified HERS pater urider the supervision of a CEC- p rovid r. 03 This building incorporates one.or•'more Special'Features shown "tielow'�j0 m f' REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer anal i • Window overhangs and/or fins CITY OF LA QUINTA PLANNING DEPARTMENT atlon Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. - CA ilding Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.20 3.24 0.96 22.9% Space Cooling 250.64 241.51 9.13 3.6% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 5.67 5.67 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 260.51 250.42 or. W.rh 3.9% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer anal i • Window overhangs and/or fins CITY OF LA QUINTA PLANNING DEPARTMENT atlon Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. - CA ilding Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CFI R -PRF -01 Page 2 of 10 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • Insulation Inspection Cooling System Verifications: 9 .. Nnno .. HVAC Distribution System Verifications: --None -- Domestic Hot Water System Verifications: --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems BELLOTTI RESIDENCE 4162 1 3 2 0 1 ZONE INFORMATION 01 02 F03;+�:' rC_71 M 04� n 05 06 07 Zone Name Zone Type° s --HVAC System Named " Zone FloZor,Area (ft )_ ; r #f ` ° Avg• Ceiling, Height �; i.pater Heating System 1 Water Heating System 2 (E) 3969 Conditioned ` &A r.(E)iHVAC1 X3969 7- # 10 DHW Sys 1 n/a (N) 193 Conditioned(E)FHVACI 193 M 8� DHW Sys 1 n/a Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CFI R -PRF -01 Page 3 of 10 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition NW- 640 (E) 3969 Default Wall 1992 to Pres 315 Right 640 269.656 90 Existing No NE - 928 (E) 3969 Default Wall 1992 to Pres 45 Front 928 67.862 90 Existing No SE- 781 (E) 3969 Default Wall 1992 to Pres 135 Left 781 320 90 Existing No SW - 928 (E) 3969 Default Wall 1992 to Pres 225 Back 928 162.51 90 Existing No 3969 (E) 3969 Def Roof '78 to Present 3969 Existing No NW- 137 (N) 193 R-15 Wall 315 Right 137 0 90 New N/A NE - 115 (N) 193 R-19 Wall 45 Front 115 24 90 New N/A SE- 31 (N) 193 R-15 Wall 135 Left 48 0 90 New N/A SW - 115 (N) 193 R-15 Wall 225 Back 48 F 0 90 New N/A OPAQUE SURFACES — Cathedral Ceilings ' 01 02 03 o�;: „04 05� �06 07 0fl 08 09 10 11 12 13 Name Zone Type ,� .Otientatiofe ,n, (ft2) �. Skylights. A ea (ft2)(x Uloof-.Rise,, m12)j. g Roof `� Pitch r Roof* Tilt(deg)� Roof Reflectan ce Roof Emittance Framin g Factor Status Verified Existing Condifion 193 (N) 193 Cathedral specify - 193 0 0.2 0.02 0.95 0.1 0.85 0.1 New N/A ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic (E) 3969 Attic Roof(E) 3969 Ventilated 5 0.1 0.85 No No Existing No Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CF1 R -PRF -01 Page 4 of 10 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition 4060 NW- 640 (Right -315) 4.0 6.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No 1470 NW- 640 (Right -315) 1.3 7.0 8.791 80.0 0.71 0.73 Insect Screen (default) Existing No 14702 NW- 640 (Right -315) 1.3 7.0 8.791 80.0 0.71 0.73 Insect Screen (default) Existing No 3060 NW- 640 (Right -315) 3.0 6.0 1 18.0 0.71 0.73 Insect Screen (default) Existing No 30602 NW- 640 (Right -315) 3.0 6.0 1 18.0 0.71 0.73 Insect Screen (default) Existing No 1420 NW- 640 (Right -315) 1.3 2.0 1.023 2.7 0.71 0.73 Insect Screen (default) Existing No 2040 NE - 928 (Front -45) 2.0 4.0 1 8.0 0.71 0.73 Insect Screen (default) Existing No 4456 NE - 928 (Front -45) 2.0 4.0 2.139 17.1 0.71 0.73 Insect Screen (default) Existing No 1616 NE - 928 (Front -45) 1.5 1.5 1 2.3 0.71 0.73 Insect Screen (default) Existing No 16162 NE - 928 (Front -45) 1.5 1.5 1 2.3 0.71 0.73 Insect Screen (default) Existing No 16163 NE - 928 (Front -45) ,- 1.5;1 - 1.5- � q1 y _ � ,.2.3 y0.71 0.73 Insect Screen (default) Existing No 6060 NE - 928 (Front -45) lfrf X6.0; 6.6t- 1 F '%36.0 16.71 } 0 737 Insect Screen (default) Existing No 60602 SE- 781 -(Left -`135)36.0 0.71' 10, Insect Screen (default) Insect Existing No 60603 SE- 781 (L'eft-135) i-6.0P""�r x»6.0 f t.-1_ �.� x;36:0 X0.71 0:73 Insect Screen (default) Existing No 8080 SE- 781 (Left -135) ` '8.0 ' ""'8.0 1' 64.0 ` .71 0.73 Insect Screen (default) Existing No 80802 SE- 781 (Left -135) 8.0 8.0 1 64.0 0.71 0.73 Insect Screen (default) Existing No 60604 SE- 781 (Left -135) 6.0 6.0 1 36.0 0.71 0.73 Insect Screen (default) Existing No 60605 SE- 781 (Left -135) 6.0 6.0 1 36.0 0.71 0.73 Insect Screen (default) Existing No 6080 SE- 781 (Left -135) 6.0 8.0 1 48.0 0.71 0.73 Insect Screen (default) Existing No 60802 SW - 928 (Back -225) 6.0 8.0 1 48.0 0.71 0.73 Insect Screen (default) Existing No 40602 SW - 928 (Back -225) 4.0 6.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No 40603 SW - 928 (Back -225) 4.0 6.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No 6050 SW - 928 (Back -225) 6.0 5.0 1 30.0 0.71 0.73 Insect Screen (default) Existing No 2650 SW - 928 (Back -225) 6.0 5.0 0.417 12.5 0.71 0.73 Insect Screen (default) Existing No 40604 SW - 928 (Back -225) 4.0 6.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No 40605 NE - 115 (Front -45) - --- 1 24.0 0.40 0.35 Insect Screen (default) New N/A Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration DateMme: HERS Provider: CaICERTS inc. - CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Page 5 of 10 Calculation Description: Title 24 Analysis. Input File Name: 2R-030 - 51080 MARBELLA'CT..ribd16x ` 3 OPAQUE DOORS " 01 02 03 04 05 06 Name - Side of Building Area (ft2) U -factor Status Verified Existing Condition - 2868 NW- 640 19.0 0.50 Existing y No 3680 NW- 640 28.0 0.50 Existing No "H ERS PROVIDE -.. V i Registration Number:217-P010162784C-000-000-0000000-0000 Registration DateRme: - HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 ' . Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CF1 R -PRF -01 Page 6 of 10 OVERHANGS AND FINS 01 02 03 04 05 06 07 0809 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up 4nRn 8 n 1 R A n n n n n 0 0 0 0 1470 10 0.1 10 10 0 0 0 0 0 0 0 0 0 14702 10 0.1 10 10 0 0 0 0 0 0 0 0 0 3060 2 0.1 2 2 0 0 0 0 0 0 0 0 0 30602 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1420 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2040 2 0.1 2 2 0 0 0 0 0 0 0 0 0 4456 2 0.1 2 2 0 0 0 0 0 0 0 0 0 1616 2 0.1 2 2 0 0 0 0 0 0 0 0 0 16162 2 0.1 2 2 0 0 0 0 0 0 0 0 0 16163 2 0.1 �=2 n2F j—{"-'�.- 0' =7! 0 on 0 0 0 0 0 0 6060 60602 2 2 n 0.1 <,` 0.1 2 D' 2',,l ; I f 2 � Q� `"- U' 2" � 6J �, 0 ` �� 0 ct:'i 0 $ OU C t Q U 0 0 0 0 0 0 0 0 0 0 0 0 6060 3 2 ""o''1 .. 2 F 2 j7U5 R r _ 1, 07) F 0► 0 0 0 0 0 8080 10 0.1 10 10 0 0 0 0 0 0 0 0 0 80802 10 0.1 10 10 0 0 0 0 0 0 0 0 0 60604 2 0.1 2 2 0 0 0 0 0 0 0 0 0 60605 2 0.1 2 2 0 0 0 0 0 0 0 0 0 6080 10 0.1 10 10 0 0 0 0 0 0 0 0 0 60802 10 0.1 10 10 0 0 0 0 0 0 0 0 0 40602 2 0.1 2 2 0 0 0 0 0 0 0 0 0 40603 2 0.1 2 2 0 0 0 0 0 0 0 0 0 6050 2 0.1 2 2 0 0 0 0 0 0 0 0 0 2650 2 0.1 2 2 0 0 0 0 0 0 0 0 0 40604 10 0.1 10 10 0 0 0 0 0 0 0 0 0 -Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Dateffime: HERS Provider: CaICERTS inc. . CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CF1 R -PRF -01 Page 7 of 10 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 1 0.1 None 0.8 No Existing No • Cavity/ Frame: no insul. / 2x4 Top Chrd (N) 193 193 0.1 2x4 Top Chord of Roof Truss @ 24 0 No Roof Deck: Wood Siding/sheathing/decking Attic Roof(E) 3969 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Def Roof '78 to Present attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 21 0.045 Over Ceiling Joists: R-11.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-13 / 2x4 Default Wall 1992 to Pres Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Sheathing/ Insulation: R5 Sheathing • Cavity / Frame: R-21 / 2x8 • Roof Deck: Wood Siding/sheathing/decking R-21 Roof Cathedral Cathedral Ceilings Wood Framed Ceiling 2x8 @ 16 in. O.C. R 21 0.039 Roofing: Light Roof (Asphalt Shingle) ( 00C. 095 • Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 R-15 Wall Exterior Walls Wood Framed Wal D 2x4:@ 16 R 15q ')_� (,0 Exterior Finish: 3 Coat Stucco U U 0 Inside Finish: Gypsum Board R-19 Wall Exterior Walls Wood Framed -Wall �"'� 6 @ 1 �. . OC R 19 �U_ � 0 072 Cavity / Frame: R-19 / 2x6 Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition 39692 (E) 3969 1 3969 1 0.1 None 0.8 No Existing No 1932 (N) 193 193 0.1 None 0 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required --- -Registration Number: 217-P010162784C-000-000-0000000-0000 Registration DateMme: HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Calculation Description: Title 24 Analysis Input File Name: 2R-030 - 51080 MARBELLA CT..ribdl6x CFI R -PRF -01 Page 8 of 10 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Energy Factor or Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss / Recovery Eff NEEA Heat Pump Type Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 1 0.575 EF 1 40000 Btu/hr I n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 Heating System Cooling System Insulation Supply Duct Return Duct Name System Type Name Ducted � ! [ Name ^-- -� Ducfed Distribution System Fan teT_— Floor Area ;; Served Status Verified Existing Condition (E) HVAC1 Other Heating and Cooling System Heatingt + Component +1--� Yes Cooling' "Component 1- N 3 Yes Air Distribution, * k rr `System 1 €HVAC Fan 4162 Existing No HVAC - DISTRIBUTION SYSTEMS '"' "" "" 4..�* CA 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic (Ventilated and Existing (not 6.0 Attic Attic None Existing No N/A System 1 Unventilated) specified) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required -Registration Number: 217-Po10162784C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. -,CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 Project Name: BELLOTTI RESIDENCE Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Page 9 of 10 Calculation Description: Title 24 Analysis r Input File Name:.2R-030 =51080 MARBELLA CT,.ribd16x 1 - �'O�*RTS )C.' C Crk nc. HE R,5 P R 0 • . v - - � i .. } •• -' - - �, .., .i . -t . • _,. _ - moi. ,g . -Registration Number: 217-Po101627e4C-000-000-0000000-0000 Registration Date/Time: HERS Provider: CaICERTS inc. .-.CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version"- CF1 R-05092017-695 Report Generated at: 2017-06-22 10:10:39 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: BELLOTTI RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 10:09, Thu, Jun 22, 2017 Input File Name: 2R-030 - 51080 MARBELLA CT..ribd16x CF1 R -PRF -01 Page 10 of 10 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: — .- ARMANDO CHAVEZ Company: Signature Date: TITLE 24 OF THE DESERT Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this'Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement.agencyforapproval:with,this<building permit application. >' Responsible Designer Name: 1(Lit s' Responsible Designer Signature: t Rub en RomeroLr0' Company:Date H E S Signed - GLS ARCHITECTURE GROUP INC Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: P760-340-3528 Palm Desert, CA 92260 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. _Registration Number: 217-P010162784C-000-000-0000000-0000 Registration Date/Time: -,,CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 r . Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2017-06-22 10:10:39 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name BELLOTII RESIDENCE'S addition Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 6/22/2017 Project Address 51080 MARBELLA CT. LA QUINTA California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 4,162 Addition 193 # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Slab Unheated Slab -on -Grade - no insulation 3,969 Perim = 0' Existing Roof Wood Framed Attic R 21 3,969 Existing Wall Wood Framed R 13 2,457 Existing Door Opaque Door - no insulation 47 Existing Roof Wood Framed Rafter R 21 193 Add=R-5.0 New Slab Unheated Slab -on -Grade - no insulation 193 Perim = 0' New Wall Wood Framed R 15 323 New Wall Wood Framed R 19 91 New FENESTRATION I Total Area: 797 Glazing Percentage: 19.1%1New/Altered Average U -Factor: Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades 0.40 Status Right (NM 24.0 0.710 0.73 8.0 none Bug Screen Existing Right (NW) 160.0 0.710 0.73 10.0 none Bug Screen Existing Right (NIA 38.7 0.710 0.73 2.0 none Bug Screen Existing Front (NE) 67.9 0.710 0.73 2.0 none Bug Screen Existing Left (SE) 144.0 0.710 0.73 2.0 none Bug Screen Existing Left (SE) 176.0 0.710 0.73 10.0 none Bug Screen Existing Rear (SW) 72.0 0.710 0.73 10.0 none Bug Screen Existing Rear (SKO 90.5 0.710 0.73 2.0 none Bug Screen Existing Front (NE) 24.0 0.400 0.35 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 3 Central Furnace 75% AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status (E) HVAC Ducted Ducted Attic 6.0 Existing WATER HEATING Qty- Type Gallons Min. Eff Distribution Status EnerqvPro 7.1 by Ener Soft User Number: 20648 ID: 17 -GLS -030-2R Pae 13 of 17 2016 Low -Rise Residential Mandatory Measures Summary s NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. ' Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per § 110.6(a)1' NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/l.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). ' Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES § 110.6(b):: 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: asketed, or weather stripped. § 110.8(a): s Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(1): material must meet the requirements of 110.8(i) when the installation of a cool roof is specified on the CF1 R. § 110.80):. Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.' Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average LI -factor must not exceed 0.043. Minimum R-19 or weighted average LI -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U -factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation: Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g). Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This 1 § 150.0(g)l: 150.0 requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum LI -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: - § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'• Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* . § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. -§ 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pitot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool ands a heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. F1 2016 Low -Rise Residential Mandatory Measures Summary •T J i. dryer vent. Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any § 150.0(h)3A: dryer vent. Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by § 150.0(h)3B: manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; ' piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.0(j)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B:� Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l : 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr: § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5: § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a • contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. . CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that' meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)g: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12:. conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. ' 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts tc supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed s-.atic pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nomi ial cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic, testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and eery zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard E2.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)lA: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater teat allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)l: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the lifter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix he pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specked requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires nust meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 1 50.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)lA: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served b� a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings; § 150.0(k)l D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)l E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Nght lights do not need to be controlled by vacancy sensors. § 150.0(k)l F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the mansfacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)l G: with Reference Joint Appendix JA8. Installed lamps must be marked with °JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)l H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must he marked with °JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that pernit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufadlurer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the cootrol is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 1'0.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; rreets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements h § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dinmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 4. IQ 2016 Low -Rise Residential Mandatory Measures Summary Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must § 150.0(k)2J: be controlled by a vacancy sensor. Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with § 150.0(k)2K: Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3A: § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)3C: 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in 110.9, 130.0,130.2, 130.4, 140.7 and 141.0. Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more § 150.0(k)3D: vehicles per site must comply with thea licable requirements in 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of § 150.0(k)4: ower as determined according to § 130.0(c). Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the § 150.0(k)5: applicable requirements for nonresidential garages in 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane." § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric".