Loading...
BPOL2017-013278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: BPOL2017-0132 �i °F lwQ�rw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Property Address: 53061 AVENIDA MARTINEZ APN: 774061015 Application Description: HAMRICK RESIDENCE / POOL & SPA Property Zoning: Application Valuation: $23,800.00 Applicant: JAVIER ARTURO PEREZ RAYGADA FOD 73700 HIGWAY 111 STE 9 I PALM DESERT, CA 92260 JU I AUG 2 2 2017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C53 License No.: 940021 /Date:, �_ZZ—! Coor: / OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section.7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work' himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_�_) I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 77.7-7153. Date: 8/17/2017 Owner: LES HAMRICK 53061 AVENIDA MARTINEZ LA QUINTA, CA 9253 Contractor: JAVIER ARTURO PEREZ RAYGADA 73700 HIGWAY 111 STE 9 PALM DESERT, CA 92260 (760)610-3435 Llc. No.: 940021 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one o' the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: EXEMPT Policy Number: I certify that in the performance of :he work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 31700 of the Labor Code, I shall forthwith comply with those provisions. D� .a e-Appl icant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,00D). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOF. IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND,ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on thi: application. 1. Each person upon whose behalf this appli:ation is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of .ssuance of such permit, or cessation of work for 180 days will subject permit to cancel ation. ' ' I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordi-iances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. 9:e 0 Signatu�'re (Applicant ): Date: 8/17/2017' Application Number: BPOL2017-0132 Owner: Property Address: 53061 AVE NIDA MARTINEZ LES HAMRICK APN: 774061015 53061 AVENIDA MARTINEZ ' Application Description: HAMRICK RESIDENCE / POOL & SPA LA QUINTA, CA 92253 Property Zoning: Application Valuation: $23,800.00 Applicant: Contractor: JAVIER ARTURO PEREZ RAYGADA JAVIER ARTURO FEREZ RAYGADA 73700 HIGWAY 111 STE 9 73700 HIGWAY 111 STE 9 . PALM DESERT, CA 92260 PALM DESERT, CA 92260 (760)610-3435_ --------------- ---------- --------------------------------- Llc. No.: 940021 --- ---------•---------------------Detail: POOL & SPA. (DENISE POELTLER ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2016 CALIFORNIA BUILDING CODE. Total. Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: $299.36 r FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-203060 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION _ ACCOUNT QTY AMOUNT SWIMMING POOL/SPA 101-0000-42404 0 $190.00 DESCRIPTION ACCOUNT QTY AMOUNT SWIMMING POOL/SPA PC 101-0000-42600 0 $103.36 Total Paid for POOL I SPA: $293.36 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total. Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: $299.36 r Bin# City of La Quinta "j Building & Safety Division ?1�3 �/ 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit# Project Address: S'3 c� dV �7 Owner's Name: A.P. Number Address: S-3_061 4C7- Z Legal Description: City, ST, Zip: �lJ e� �1 Z2.S3 Contractor: J4V/&%C /+- T-,5/e&Z Telephone: .•�.bp_ly3f_8O1?q Address: �3 _ � eW y f� s'���-�' Project Descriptlon: City, ST, Zip: �9�/ 1 �f / 522,6 a /lJL-mow M01- if S775+ Telephone: State Lic. #: GoO City Lic #: Arch, Engr., Designer: Address: 44, Z.� C�✓'/L��i/� L1I/ ; /;� O City, ST, Zip: Telephone: -7/0— � Z— � // Construction Type: Proj. Type New Add'n Occupanncy: Alter Repair Demo State Lic. #: C_ �3 (�/Z/� Name of Contact: -' SgFt: #Stories # Units: Telephone of Contact: x- 0 -.29/ _ 311.3 Estimated Value of Project: 23/ ego APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMFII' FEES Plan Sets • Plan Check Submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan Check Balance: Title 24 Calcs Plans Picked Up Construction: Flood Plain Plan Plans Resubmitted Mechanical: Grading Plan 2nd Rev, Ready for corrections / Electrical: Subcontractor List Called Contact Person Plumbing: Grant Deed Plans Picked Up S.M.I. HOA Approval Plans Resubmitted Grading IN-HOUSE 3rd Rev, Ready for corrections / Developer Impact Fee Planning Approval Called Contact Person A.I.P:P.. Pub. Wks. Apps Date of permit issue School Fees Total Permit Fees i Client: Les Hamrick Project Address : 53-061 Avenida Martinez. La Quinta, CA 92253 Contractor's Info: Javier A. Perez Lic. C-53 / #940021 73-700 Highway 111, Suite 9 Palm Desert, CA 92260 AU CITY OF LA QUINTA 1 of ,COMMUN�TY Generalica,, , DEVELOPMENT ® S Free form pool (12'x 24') with attached round spa (6' diameter) Raised bond beam and planter (+18" ) along long side of pool (west) Pool: Area: 209 sf I Perimeter: 66 If. Depth: T to 5' 1 Elevation: Zero Spa: Area: 28 sf. Perimeter: 19 If. Depth: 3'6" 1 Elevation: 18" EQUIPMENT • One (1) Variable Speed Pump for jets & circulation • One (1)1/2 hp pump for water shooters • One (1) Cartridge Filter 325 sf. • One (1) Heat Pump 50k BTU • One pool light 300w. halogen white • One spa light 100w. halogen white • Filtration Pump water flow: 85 gpm @ 3,000 rpm • All equipment shall be installed per manufacturer's recommendations and in accordance with local regulations. • All equipment shall be seismically anchored. • All equipment to be installed comply with the requirements of the California Energy Efficiency Standards, Section 5.2.9. Pool and Spa Equipment, §114. PLUMBING • 14AWG tracerwire around at underground gas pipe. • S-40 PVC water pipes of 2" diameter for pool & spa suction, and 1-1/2" for pool & spa return lines, and jets. • 40' from pump to suction (skimmer) • 6 jets in spa • New skimmer, auto fill unit as well as dedicated suction for pool sweeper. • Pool & spa heating equipment will be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built- up connections for future solar heating. (CEC §114(b)1) ELECTRICAL • 41' If. from panel to equipment site. • Solid copperwiring #10 • None outdoor surrounding or landscaping lightning. • Two pole 30 amp. GFCI breaker to be added on main panel exclusively for poolequipment. • All outlets supplied by single= phase, 15A and -20A,125V or 240V branch circuits for swimming pool pump motors are required to have GFCI protection, It should be noted that 680.22(6) applies to these outlets regardless of their proximityto the swimming pool and that it applies to cord - and -plug connected and direct connected (hard -wired) swimming pools pump motors (California Electrical Code 5680.22(B)) , MASONRY _ • 275 sf. of concrete deck around pool & spa - • Pool's floor and walls will be covered with mini pebble • Porcelain or glass the to be installed in the waterline. EOUIPOTENTIAL BONDING • Structural reinforcing steel in concrete sh0, equipment, electrical parts, and any metallic components will be bonded to the existing equipotential bonding grid with a solid copper conductor not smaller than 8 AWG with listed pressure connectors, terminal bars, exothermic welding, or other listed approved means. • Perimeter surfaces. We will use equipotential bonding conductor meeting all of the following requirements: (1) 8 AWG bare solid copper bonding conductor connected to the pool reinforcing steel. (2) The bonding conductorwill follow the contour of the perimeter surface. (3) Bonding conductor will be 18 to 24 in. from the inside walls of the pool. (4) Bonding conductorwill be secured within or under the perimeter surface 4 to 6 in. below the subgrade. SAFETY • Split pool and spa main drains T feet away from each other and hydraullically balanced with anti-entrapment/vortex main drain covers (approved by ASTM/ASME) in compliance with VGB SafetyAct. • Enclosure with self closing, self latching doors and exit alarms on doors to backyard to be provided. PROPERTY LINE- BLOCK WALL 6' TALL Raised Planter�d� J Pool Light +1811 ITY OF LA ♦ "'�'r.. +n.T+ Mme.^'" " r'�r. ..M.�; , �^'�3.. s & SAFET� !r= PT .:. Spa Main��, its - UILDING APP to V FOR CONSTRUC O io o / Shallow 1 o I N Existing Patio _ ATE Wall +36"'��4 Electrical Line Lb Z ;.. , Spa Light -10AWG - 75 If Skimmer ain Drain Ce Equipment K r. U U V QU PROPERTY LINE- BLOCK WALL 6' TALL O ` Raised ,• 9 A�� y Auto -fill Bond Beam i�' +1811 O Existing House AU CITY OF LA QUINTA 1 of ,COMMUN�TY Generalica,, , DEVELOPMENT ® S Free form pool (12'x 24') with attached round spa (6' diameter) Raised bond beam and planter (+18" ) along long side of pool (west) Pool: Area: 209 sf I Perimeter: 66 If. Depth: T to 5' 1 Elevation: Zero Spa: Area: 28 sf. Perimeter: 19 If. Depth: 3'6" 1 Elevation: 18" EQUIPMENT • One (1) Variable Speed Pump for jets & circulation • One (1)1/2 hp pump for water shooters • One (1) Cartridge Filter 325 sf. • One (1) Heat Pump 50k BTU • One pool light 300w. halogen white • One spa light 100w. halogen white • Filtration Pump water flow: 85 gpm @ 3,000 rpm • All equipment shall be installed per manufacturer's recommendations and in accordance with local regulations. • All equipment shall be seismically anchored. • All equipment to be installed comply with the requirements of the California Energy Efficiency Standards, Section 5.2.9. Pool and Spa Equipment, §114. PLUMBING • 14AWG tracerwire around at underground gas pipe. • S-40 PVC water pipes of 2" diameter for pool & spa suction, and 1-1/2" for pool & spa return lines, and jets. • 40' from pump to suction (skimmer) • 6 jets in spa • New skimmer, auto fill unit as well as dedicated suction for pool sweeper. • Pool & spa heating equipment will be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built- up connections for future solar heating. (CEC §114(b)1) ELECTRICAL • 41' If. from panel to equipment site. • Solid copperwiring #10 • None outdoor surrounding or landscaping lightning. • Two pole 30 amp. GFCI breaker to be added on main panel exclusively for poolequipment. • All outlets supplied by single= phase, 15A and -20A,125V or 240V branch circuits for swimming pool pump motors are required to have GFCI protection, It should be noted that 680.22(6) applies to these outlets regardless of their proximityto the swimming pool and that it applies to cord - and -plug connected and direct connected (hard -wired) swimming pools pump motors (California Electrical Code 5680.22(B)) , MASONRY _ • 275 sf. of concrete deck around pool & spa - • Pool's floor and walls will be covered with mini pebble • Porcelain or glass the to be installed in the waterline. EOUIPOTENTIAL BONDING • Structural reinforcing steel in concrete sh0, equipment, electrical parts, and any metallic components will be bonded to the existing equipotential bonding grid with a solid copper conductor not smaller than 8 AWG with listed pressure connectors, terminal bars, exothermic welding, or other listed approved means. • Perimeter surfaces. We will use equipotential bonding conductor meeting all of the following requirements: (1) 8 AWG bare solid copper bonding conductor connected to the pool reinforcing steel. (2) The bonding conductorwill follow the contour of the perimeter surface. (3) Bonding conductor will be 18 to 24 in. from the inside walls of the pool. (4) Bonding conductorwill be secured within or under the perimeter surface 4 to 6 in. below the subgrade. SAFETY • Split pool and spa main drains T feet away from each other and hydraullically balanced with anti-entrapment/vortex main drain covers (approved by ASTM/ASME) in compliance with VGB SafetyAct. • Enclosure with self closing, self latching doors and exit alarms on doors to backyard to be provided. Raised Planter�d� Pool Light +1811 0 Spa Main��, its Drains io o / Shallow 1 x �',:End 3' Equipment Wall +36"'��4 Electrical Line ;.. , Spa Light -10AWG - 75 If Equipment K r. U U V QU PROPERTY LINE- BLOCK WALL 6' TALL AU CITY OF LA QUINTA 1 of ,COMMUN�TY Generalica,, , DEVELOPMENT ® S Free form pool (12'x 24') with attached round spa (6' diameter) Raised bond beam and planter (+18" ) along long side of pool (west) Pool: Area: 209 sf I Perimeter: 66 If. Depth: T to 5' 1 Elevation: Zero Spa: Area: 28 sf. Perimeter: 19 If. Depth: 3'6" 1 Elevation: 18" EQUIPMENT • One (1) Variable Speed Pump for jets & circulation • One (1)1/2 hp pump for water shooters • One (1) Cartridge Filter 325 sf. • One (1) Heat Pump 50k BTU • One pool light 300w. halogen white • One spa light 100w. halogen white • Filtration Pump water flow: 85 gpm @ 3,000 rpm • All equipment shall be installed per manufacturer's recommendations and in accordance with local regulations. • All equipment shall be seismically anchored. • All equipment to be installed comply with the requirements of the California Energy Efficiency Standards, Section 5.2.9. Pool and Spa Equipment, §114. PLUMBING • 14AWG tracerwire around at underground gas pipe. • S-40 PVC water pipes of 2" diameter for pool & spa suction, and 1-1/2" for pool & spa return lines, and jets. • 40' from pump to suction (skimmer) • 6 jets in spa • New skimmer, auto fill unit as well as dedicated suction for pool sweeper. • Pool & spa heating equipment will be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built- up connections for future solar heating. (CEC §114(b)1) ELECTRICAL • 41' If. from panel to equipment site. • Solid copperwiring #10 • None outdoor surrounding or landscaping lightning. • Two pole 30 amp. GFCI breaker to be added on main panel exclusively for poolequipment. • All outlets supplied by single= phase, 15A and -20A,125V or 240V branch circuits for swimming pool pump motors are required to have GFCI protection, It should be noted that 680.22(6) applies to these outlets regardless of their proximityto the swimming pool and that it applies to cord - and -plug connected and direct connected (hard -wired) swimming pools pump motors (California Electrical Code 5680.22(B)) , MASONRY _ • 275 sf. of concrete deck around pool & spa - • Pool's floor and walls will be covered with mini pebble • Porcelain or glass the to be installed in the waterline. EOUIPOTENTIAL BONDING • Structural reinforcing steel in concrete sh0, equipment, electrical parts, and any metallic components will be bonded to the existing equipotential bonding grid with a solid copper conductor not smaller than 8 AWG with listed pressure connectors, terminal bars, exothermic welding, or other listed approved means. • Perimeter surfaces. We will use equipotential bonding conductor meeting all of the following requirements: (1) 8 AWG bare solid copper bonding conductor connected to the pool reinforcing steel. (2) The bonding conductorwill follow the contour of the perimeter surface. (3) Bonding conductor will be 18 to 24 in. from the inside walls of the pool. (4) Bonding conductorwill be secured within or under the perimeter surface 4 to 6 in. below the subgrade. SAFETY • Split pool and spa main drains T feet away from each other and hydraullically balanced with anti-entrapment/vortex main drain covers (approved by ASTM/ASME) in compliance with VGB SafetyAct. • Enclosure with self closing, self latching doors and exit alarms on doors to backyard to be provided. I Self-closing gate & latch Self-closing gate & latch lqq C" 7T --F T CONSTRUCTION & GOVERNMENT CODES 1. The proposed construction will conform to the current codes: 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA RESIDENTIAL CODE, 2016 CALIFORNIA MECHANICAL CODE, 2016 CALIFORNIA PLUMBING CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA ENERGY CODE 2. Government Code Section 4216.2. (a) (1) Except in an emergency, any person planning to conduct any excavation shall contact the appropiate regional notification center, at least two working days, but not more than 14 calendar days, prior to commencing that excavation, if the excavation will be conducted in an area that is known, or reasonably should be known, to contain subsurfcae installations other than the underground facilities owned or operated by the excavator and, if practical, the excavator shall delineate with white paint or other suitable markings the area to be excavated. 3. Construction hours will comply with City regulations. BVoLwrL oR2 0 va' I=D io I Self-closing gate & latch Self-closing gate & latch lqq C" 7T --F T CONSTRUCTION & GOVERNMENT CODES 1. The proposed construction will conform to the current codes: 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA RESIDENTIAL CODE, 2016 CALIFORNIA MECHANICAL CODE, 2016 CALIFORNIA PLUMBING CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA ENERGY CODE 2. Government Code Section 4216.2. (a) (1) Except in an emergency, any person planning to conduct any excavation shall contact the appropiate regional notification center, at least two working days, but not more than 14 calendar days, prior to commencing that excavation, if the excavation will be conducted in an area that is known, or reasonably should be known, to contain subsurfcae installations other than the underground facilities owned or operated by the excavator and, if practical, the excavator shall delineate with white paint or other suitable markings the area to be excavated. 3. Construction hours will comply with City regulations. BVoLwrL oR2 p 0 C Z rt .. �m _c oU) +gam �0) 1 �_�' r+ n, rn B co 3 PROPERTY LINE- BLOCK WALL 6' TALL op ; '1 fT1 o I a / X Q 3 o 3 7 v D rn rt _ m..a Y„ p ter r O 0 90 > - -i m DN Z z g :i > rn Q, m r X 0 Ln 5 � D r L0 r 'rn D O r � r Vj �enida Martinez z� D N N w W vrD 7 i..i r C O R° n O �+ rD E to O Q � D O rD 1 w O •_i Ln �enida Martinez z� D N N w W r 7 i..i r C O v �+ rD p O � D O rD 10 w O 0 Ln 7:) x OQjr� • O W O f\J cr • • W r flJ i..i C O v rD O � D rD = w • n Ln 7:) rD D � N —' fv.. 0 � Q0