Loading...
BRES2017-002178-495 CALLE TAMPICO Ct 0 D �NMU�iI/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2017-0021 Property Address: 56670 MERION APN: 762032002 Application Description: SPITZER / ADDITION 72 SQ FT AND REMODEL KITCHEN Property Zoning: Application Valuation: $6,500.00 Applicant: ROB PITCHFORD 77622 COUNTRY CLUB STE 0 MAR 2 4 Z017 PALM DESERT, CA 92211 P 1 0 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the { alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: roI, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he orhe did not build or improve for the purpose of sale.). V _ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Co tractors' State License Law.). 'I am exempt under Sec. . B.&P.C. foikthlslr ason Date: *i Owner CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/24/2017 Owner: PAUL SPITZER 56670 MERICIV LA QUINTA, CA 92253 Contractor: OWNER BUILDER LIC. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number: _ certify that in the performance ofthe work for which this permit is issued, I shal not employ any person in any manner sa as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sectio 00 thabfer Code, I shall forthwith comply with those provisions. %`' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMFVAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FCR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to t ie Building Official for a permit subject to the conditions and restrictions set forth on th s application. 1. Each person upon whose•behalf this appl cation is made, each person at whose request and for whose benefit work is perforned under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to tfie work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issLance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and stat aws sting to bu'I�ing construction, and hereby authorize representatives of this cit t nter ont bove- meenntiioned property for inspection purposes. 'a Date� Signature (ApplicantTr.Agent):�+ Application Number: BRES2017-0021 Property Address: 56670 MERION APN: 762032002 Application Description: SPITZER / ADDITION 72 SQ FT AND REMODEL KITCHEN Property Zoning: Application Valuation: $6,500.00 Applicant: ROB PITCHFORD 77622 COUNTRY CLUB STE 0 PALM DESERT, CA 92211 Owner: PAUL SPITZER 56670 MERION LA QUINTA, CA 92253 Contractor: OWNER BUILDER Date: 3/24/2017 Llc. No.: -------------------------------------------------------------------------------------------- Detail: ADDITION OF 73 SQ. FT. UNDER EXISTING FOOR LINE. PER 2016 CRC CODES 0 .i . FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $127.68 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $179.36 Total Paid for ADDITION: $307.04 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES ADMINISTRATIVE STAFF 101-0000-42600 0.25 $10.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 3 $285.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER 101-0000-42600 1 $95.00 Total Paid for BLDG CITY STAFF - PER HOUR: $400.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT Credit Card Fee 101-0000-43505 0 $16.81 Total Paid for Credit Card Fee: $16.81 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,OOOSF, PC 101-0000-42600 0 $50.16 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $202.16 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT APPLIANCE REPAIR/ALTERATION PC 101-0000-42600 0 $5.07 Total Paid for MECHANICAL: $17.74 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.85 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.85 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Bin # City of La Quinta Building U Safety Division 78-495 Calle Tampico Permit 9t La Quinta, CA 92253 - (760) 777-701;2 ✓ Building Permit Application and Tracking Sheet -CSR �s a �- aoa2 Project Address: 56 '-'e�7 70 M F_,P,-(o k1 Owner's Naine: A. P. Number: 6 "eC) -3 2 coo Address: 56 - 6 70 Legal Description: t&r City, ST, Zip: t,4 Ql' «TA l,'A C ontractor: Telephone: v 06 P Address:. Project Description: City, ST, Zip:r.0 e-71 Telephone: . G State Lie. # : City Lie. #: AFe�., -Fsar., Designer: J r f Address:77-6 Zt✓ C�)Ufirv/ � City, ST, Zip: � QS Telephone: 416 6 ar cYtru Conscti nTYPe: Occup Lis ,. Repair- air Demo .er Add'n ProJecttYP �circleon NewStato Name of Contact Person: C ` � ��C > Sq. Ft.: %may #Stories: #Units: Telephone # of Contact Person: �6t� ,� � Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE tl Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes.) Reviewed, ready for corrections Plan Check Depos-t Truss Cates. Called Contact Person Plan Ch k e, Title 24 Cates. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2'. Review, ready for corrections/issue I Electrical . Subcontactor List Grant Deed Called Contact Person Plans picked up Plumbing, CITb' 0� QUI `t COMM! MY MFVE LOP S.M.I. MEN II.O.A. Approval Plans resubmitted Grading IN HOUSE:- '`' Review, ready for corrections/issue Developer Impact Fee Planning Approval, Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, I Total Pcrmit Fee! Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: .. INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: PGA West Nicholasl Date: March 20, 2017. Owner's Name: Paul Spitzer Phone No. 858-735-7285 Project Address: 56-670 Merion, LaQuinta Project Description: Addition AM: 762-032-002 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 73 Sq, Ft. Certification of Applicant/Owners: The person signing certif that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authori d to ign on be alf of the owner/developer. Dated: March 20, 2017 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 73 Pursuant to AB 181 any room additions or enclosures of 500 Amount per Sq.Ft. $0.00 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's Amount Collected $0.00 jurisdiction are exempt from developer fees. Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Laurie Howard, Secretary Signature: &4d Iru Q2 �2ti e NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted.. b1\1:c/huydoesidevfecs/certificate of compliance form updated 3-2007 11/2010 YouNGK� k1'" ENGINEERING ,� .fry S. C FI V ! C G S t' o f W .•``x.G7;.7`t .R.. (JJ - • a _; ti r - • :.e: Letter of Transmittal To: City of La Quinta Today's Date: 3-21-17 78-495 Calle Tampico City Due Date: 3-23-17 La Quinta, CA 92253 Project Address: 56670 Merion Attn: MARY Plan Check #: BRES2017-0021 Submittal: 1St ❑ 4th O 2nd ❑ - 55th ❑ 3rd ❑ Other: We are forwarding:_ By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: J Descriptions: Includes: # Of Descriptions: 4 Copies: ❑ Structural Plans ®. Revised Struct. Plans ❑ Structural Calculations ❑ Revised Struct. Calcs ❑ Truss Calcs ❑ Revised Truss Calcs ' ❑ Soils Report - Update ❑ Revised Soils Report Structural P/C Responses O Approved Structural Plans 1 / Comments 1 O 1 Redlined Structural Plans D 1 Approved Structural Calcs O 1 Redlined Structural Calcs O Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. Transit Per Diem= Admin Time = 0.25 hrs. Structural Engineer/Principal Review Time = 0.0 hrs. Plan Review Engineer Time = 1.0 hrs. This Material Sent for: ❑ Your Files Per Your Request ❑ Your Review- ❑ Approval ❑ Checking ❑ At the request of: Other: By: Joe Venuti Office.: (760) 772-5107 - Other:- ❑ LOPC@VALUENGR.COM � , r BUILDING ENERGY ANALYSIS REPORT PROJECT: Spitzer Residence Addition 56-670 Mericon LaQuinta, CA 92253 Project Designer: Robert A. Pitchford Design and Drafting 77-622 Country club STE O Palm Desert, CA 92260 (760) 346-2856 Report Prepared by: Jon d. Scott Scott Design and Title 2 74-818 Velie Way ST Palm Desert, CA 9212 760-200-4780 Job Number: Date: 2/13/2017 10 ��SN00 t10_4 �ll��®��Crd v�,A 1d30 4 ����� � .�ONimine �. A110 RECEI. FEB 16 2017 CM dV 1A IDUiNTA --1--comwa1v DEVELOPMENT a The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. Iasi CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE I OD Project Name: Spitzer Ca culation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribdl6x CF*RF-01 Page 1 of 8 GENERAL INFORMATION ENERGY USE SUMMARY 01 Project Name Spitzer 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 56-670 Mericon Compliance Margin Percent Improvement 04 City LaQuinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 110 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2836 15 Number of Zones 2 16 Slab Area (ft2) 2836 17 Number of Stories 1 18 Addition Cond. Floor Area 73 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 73 21 Glazing Percentage (%) 24.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins • Pipe insulation, all lines Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.56 2.59 -0.03 -1.2% Space Cooling 224.59 223.30 1.29 0.6% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 10.50 10.43 0.07 0.7% Photovoltaic Offset -- 0.00 0.00 — Compliance Energy Total 237.65 236.32 1.33 0.6% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins • Pipe insulation, all lines Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE JPOD Project Name: Spitzer Ca culation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribdl6x CFIDRF-01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: * --None— Cooling System Verifications: - -- None — HVAC Distribution System Verifications: • -- None — Domestic Hot Water System Verifications: - -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/ft2-yr)* 267.67 266.34 1.33 0.5% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Spitzer 2836 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 67 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Residence Conditioned HVAC1 2763 9 DHW Sys 1 Addition Conditioned HVAC1 73 J DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTI&E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD Project Name: Spitzer ation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribd16x CI&RF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition 20d Wall Existing Residence R-13 Wall 20 Right 962 52.5 90 Existing No 110d Wall Existing Residence R-13 Wall 110 Front 1011 133 90 j Existing No 200d Wall Existing Residence R-13 Wall 200 Left 962 233 90 Existing No 290d Wall Existing Residence R-19 Wall (W.19.2x6.16) 290 Back 1011 187 90 Existing No Roof Existing Residence R-38 Roof Attic 2763 Existing No 200d Wall 2 Addition R-21 Wall + R5 200 Left 160 64 90 New N/A 290d Wall 2 Addition R-21 Wall + R5 190 80 120 48 90 New N/A Roof 2 Addition R-38 Roof Attic 73 New N/A ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Residence Attic RoofExisting Residence Ventilated 3 0.1 0.85 Yes No Existing No Attic Addition Attic RoofAddition Ventilated 3 0.1 0.85 Yes No New No Registration Number: Registration DateTme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD Project Name: Spitzer Calculation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer -Pitchford -1 7. ribd 1 6x CFIDRF-01 Page 4of8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft) U -factor SHGC Exterior Shading Status Verified Existing Condition Ex. Window 20d Wall (Right -20) -- -- 1 20.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 2 20d Wall (Right -20) - - 1 25.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 3 20d Wall (Right -20) -- -- 1 7.5 0.85 0.70 Insect Screen (default) Existing No Ex. Window 4 110d Wall (Front -110) -- -- 1 80.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 5 110d Wall (Front -110) - - 1 8.3 0.85 0.70 Insect Screen (default) Existing No Ex. Window 6 110d Wall (Front -110) - -- 1 24.6 0.85 0.70 Insect Screen (default) Existing No Ex. Window 7 200d Wall (Left -200) - - 1 32.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 8 200d Wall (Left -200) - - 1 8.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 9 200d Wall (Left -200) - - 1 8.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 10 200d Wall (Left -200) - - 1 32.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 11 200d Wall (Left -200) -- - 1 80.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 12 200d Wall (Left -200) - - 1 25.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 13 200d Wall (Left -200) - - 1 48.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 14 290d Wall (Back -290) -- - 1 80.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 15 290d Wall (Back -290) - - 1 25.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 16 290d Wall (Back -290) -- -- 1 24.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 17 290d Wall (Back -290) - -- 1 10.0 0.85 0.70 Insect Screen (default) Existing No Ex. Window 18 290d Wall (Back -290) -- - 1 48.0 0.85 0.70 Insect Screen (default) Existing No Window 200d Wall 2 (Left -200) 8.0 8.0 1 1 64.0 1 0.30 1 0.20 1 Insect Screen (default) New N/A Window 2 290d Wall 2 (- specify --190) 8.0 6.0 1 1 48.0 1 0.30 1 0.20 1 Insect Screen (default) New N/A OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door 110d Wall 20.1 0.50 Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTI E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE i4OD Project ame: Spitzer Calculation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribd16x CFIDRF-01 Page 5 of 8 OVERHANGS AND FINS 01 02 03 04 05 06 07 Total Cavity 01 02 03 04 05 06 07 08 09 10 11 12 13 14 • Under Roof Joists: R-6.0 insul. Overhang Left Fin • Cavity/Frame: R -13.0/2x4 Top Chrd Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up Window 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Under Roof Joists: R-6.0 insul. • Cavity/Frame: R -13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Residence Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.052 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Ceiling Joists: R-9.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 R-19 Wall (W.19.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.072 Exterior Finish: 3 Coat Stucco • Under Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofAddition Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.052 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Sheathing/ Insulation: R5 Sheathing R-21 Wall + R5 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.048 Exterior Finish: 3 Coat Stucco Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTI*E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCEIOD Project Name: Spitzer Ca culation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribdl6x CFORF-01 Page 6 of 8 SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Existing Residence 2763 188 None 0.8 No Existing No Slab -on -Grade 2 Addition 73 17 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Pipe Insulation, All Lines DHW Heater 1 2 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Energy Factor or Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss / Recovery Eff NEEA Heat Pump Type Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 50 0.61 EF 40000 Btu/hr n/a n/a Na n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Name System Type Name Ducted Name Ducted Distribution System Fan System Floor Area Served Status Verified Existing Condition HVAC1 Other Heating and Cooling System Heating Component 1 Yes Cooling Component 1 Yes Air Distribution System 1 HVAC Fan 1 2836 Existing No Registration Number: Registration Dateffime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTIfE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCERlOD Project ame: Spitzer ation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer-Pitchford-17.ribdl6x HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE CRF -01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 01 02 03 04 05 06 07 09 10 Efficiency Zonally Controlled Multi -speed Compressor Insulation Name System Type EER SEER HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning system 10 12 No No N/A HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 6.0 Attic Attic None Existing No N/A Unventilated) IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01242017-695 Report Generated at: 2017-02-13 09:27:47 CERTIWE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE&OD Project Name: Spitzer Calculation Date/Time: 09:27, Mon, Feb 13, 2017 Calculation Description: Title 24 Analysis Input File Name: Spitzer -Pitchford -1 7. ribd 1 6x C*RF-01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Jon d. Scott Company: Signature Date: Scott Design and Title 24, Inc, 2/13/2017 Address: CEA/HERS Certification Identification (If applicable): 74-818 Velie Way STE 8 city/State ftm Desert, CA 92260 Phone: 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the infor on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this buld ermit a c V�del Responsible Designer Name: Resp ner Signa r - Robert A. Pitchford Company: Date Si ed: Robert A. Pitchford Design and Drafting Z / 57 1 7 Address: License: 77-622 Country club STE O City/State/Zip: Phone: Palm Desert, CA 92260 (760) 346-2856 Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01242017-695 Report Generated at: 2017-02-13 09:27:47 Ah rI L J • RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Spitzer Residence Addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 2/13/2017 Project Address 56-670 Mericon LaQuinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,836 Addition 73 # of Units 1 INSULATION Construction Type Cavity Area ft Special Features Status Roof Wood Framed Attic R 19 2,763 Add=R-19.0 Existing Wall Wood Framed R 13 2,984 Existing Door Opaque Door - no insulation 20 Existing Wall Wood Framed R 19 1,262 Existing Slab Unheated Slab -on -Grade - no insulation 2,763 Perim = 188' Existing Roof Wood Framed Attic R 19 73 Add=R-19.0 New Wall Wood Framed R 21 168 Add=R-5.0 New Slab Unheated Slab -on -Grade - no insulation 73 Perim = 17' New FENESTRATION Orientation Area(ft) I Total Area: 697 Glazing Percentage: 24-6%1New/Altered Average U -Factor: 0.30 U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (N) 52.5 0.850 0.70 none none Bug Screen Existing Front (E) 112.9 0.850 0.70 none none Bug Screen Existing Left (S) 233.0 0.850 0.70 none none Bug Screen Existing Rear (tM 187.0 0.850 0.70 none none Bug Screen Existing Left (S) 64.0 0.300 0.20 6.0 none Bug Screen New Left (S) 48.0 0.300 0.20 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status HVAC Ducted Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqyPro7.1 by EnerqySoft User Number: 6712 /D: Pae 11 of 17 ¢ I' 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Original 0812016) Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherslri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average LI -factor must not exceed 0.043. Minimum R-19 or weighted average LI -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or U -factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 1 10.8 . § 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(8)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. Is 4 a 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)26: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielcing from solar radiation that can cause degradation of the material. § 150.00)36: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL.181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l 1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with 150.0(m)l I and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)l 2. 4 4 4 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)l: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)l B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)l E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)l F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)lG: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specifed in Reference Joint Appendix JAB.' § 150.0(k)l H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's nstructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5(f); and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 4 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)l: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 1 10.10 b through § 1 10.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 1 10.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Spitzer Residence Addition 2/13/2017 System Name Floor Area HVAC 2,836 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING CFM Sensible 3,231 64,331 0 4,390 0 0 0 0 1 4,390 73,111 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output perSystem 71,000 3,193 1,464 53,135 Total Output Btuh 142,000 Output Btuhls ft 50.1 3,065 Cooling System 0 Output perSystem 48,000 0 0 0 Total Output Btuh 96,000 3,193 0 Total Output Tons 8.0 3,065 Total Output Btuh/s ft 33.9 Total Output s ft/Ton 354.5 59,264 Air System CFM perSystem 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 3,200 Exist. HVAC 73,725 7,749 142,000 Airflow cfmis ft 1.13 Airflow cfm/Ton 400.0 Outside Air % 0-0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 73,725 7,749 Aug 3 PM 142,000 Outside Air cfmis ft 0.00 Note: values above given at ARI conditions Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 105 IF 105 OF , I Outside Air ,.....1�..._.L � 0 cfm Heating Coil Supply Fan OF 3,200 cfm 104 ROOM 69 of Return Fan 69 OF 70 OF 0 2,800 cfm COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/62°F 55/54°F 55/54°F 10 IU Outside Air Ar -1-0 0 cfm Cooling Coil Supply Fan 56 / 54 OF 3,200 cfm 47.1 % (ROOM �- Return Fan 76/62°F76/62°F 75/62°F O-94 0 � 2,800 cfm EnergYPro 7.1 by EnergySoft User Number: 6712 /D: Page 16 of 17 a ZONE LOAD SUMMARY Project Name Spitzer Residence Addition Date 2/13/2017 System Name HVAC Floor Area 2,836 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM I Sensible Latent CFM Sensible Existing Residence 1.0 0 Aug 3 PM 3,124 62,200 3,111 1,392 50,515 Addition 1.0 0 Aug 3 PM 107 2,130 82 72 2,619 TOTALS 0 0 01 01 Aug 3 PM 64,331 3,193 53,135 (BLOCK LOAD) EnergyPro 7.1 by EnergySoft User Number.- 6712 ID: Page 17 of 17 ' '(P CITY. OF LA nnQUINTA .SUB-CONTR CTOR LIST �PiTZ-�JL 61'�Jc JOB ADDRESS .! 61�I v l���U PERMIT. NUMBER+,n��l?-0024WNER BUILDER This form shall .be posted on the -job with the Building Inspection Card -at all times in a conspicuous place: Only persons appearing on this list or their, employees are authorized to work on this job. Any,cbanges to this list must .be approved by the Building Division prior to commencement of work. Tailure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response: ift e./..Class catio.n.:::::..........................Co.nt. ractor..........:......:................ r:: ..L�cen :::::.:..::.::::.State..Contracto ..s. se:::;.:;:.::.;:.::::..;.:::.>;:::..;:.;:.;:.;<.:;;:::.::.;:.;:.;:.;:::.;:.;:.>:.;:<.;.;.;.Workers.. Com ensation:::lnsuca P . `:'Bus Y........................................... L Name Classification License Number Exp. Date Carrier Name IisY Number Date• Exp. License Number Exp. . DateComPanY . A B C-8 xxxxxx xx/ x xx _ e. .�StateFund Ca1ComP Format Varies) ( xxx x) (xx xx / xx )xxlxx!xx)e. STRU.C..;..STEEL..:(.0„51),..,;;. :IVIAS0NRY;:C-29::>'.>> P`LUMBI.NG:?iG'3631:><<> y:. H VlaC>:{ ....................................................... . >ELEC .RICA`1> C':j;p'::>?i>>:'>> v c1--I-1 I :::ROOF...N Ca.:(C:.3<>»'><' .... )::>:>IX / >S HEET? M .............:FWQ IN (...........)................... ................................................... ' � r .(.. . r PANTING>{C`33j`<>>;>' 'GERAMICTI.LE::`(C54:I>:' kA.N.D $:CA PI NG! :(CC: 27.)z %> :a ...................................... .... .....