Loading...
BPAT2017-0078• / Q.�i � auucla 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN Application Number: BPAT2017-0078 Property Address: 53790 AVENIDA MONTEZUMA APN: 774141003 Application Description: ESCHER / (2) DURALUM LATTICE PATIO COVERS Property Zoning: Application Valuation: $7,500.00 Applicant: LDR CONSTRUCTION SERVICES P.O. BOX 242 LA QUINTA, CA 92253 OCT 2 5 2017 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0006238 Date� Const: o v OWNER -BUILDER DE RATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (__-)1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addre! VOICE (760) 777-7125 FAX (760) 777-70i1 INSPECTIONS (760) 777-7153 Date: 10/25/2017 Owner: JAMES ESCHER 53790 AVENICA MONTEZUMA LA QUINTA, CA 92253 Contractor: LDR CONSTRUCTION SERVICES P.O. BOX 242 LA QUINTA, CA 92253 (760)413-4708 Llc. No.: :LIC -D) 06238 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew for which this permit is issued. I have and will maintain workers' :ompensation insurance, as required by ectwn 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insuranc- carrier and policy number are: Carrier: _ Policy Number: _ _ I certify that in the performance or the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sectior 3700 of the Labor Code, I shall forthwith comply with those provisions. D��n�� Applica` 7 WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100!300). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR.IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKPiOWLEDGEMENT IMPORTANT: Application is hereby made to -he Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this apFlication is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Cit+ of La Quinta, its officers, agents, and employees for any act or omission related tothe work being performed under or following issuance of this permit. 2. Any permit issued as a result of this appication becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellati )n. I certify that I have read this application and ;tate that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize represencatives of this city to enter upon the above- mentioned property for inspection purposes. n i D�/ Signature (ApplicanjoAg Date: 10/25/2017 Application Number: BPAT2017-0078 Owner: Property "Address: '53790 AVENIDA MONTEZUMA JAMES ESCHEF APN: 774141003 53790 AVENIE•A MONTEZUMA Application Description: ESCH£R / (2) DURALUM LATTICE PATIO COVERS LA QUINTA, CA 92253 Property Zoning: Application Valuation: $7,500.00 Applicant: Contractor: LDR CONSTRUCTION SERVICES LDR CONSTRUC=TION SERVICES P.O. BOX 242 P.O. BOX 242 LA QUINTA, CA 92253. LA QUINTA, CA 92253 (760)413-4702. --------------------------------------------------------------------------------------------- Llc. No.::LIC-0006238 Detail: ESCHER / (1) 304SF DURALUM LATTICE PATIO COVER AT NORTH EAST REAR YARD (2) 299SF DURALUM'LATTICE PATIO COVER AT NORTH SIDE REAR YARD THIS PERMIT DOES NOT INCLUDE ELECTRICAL INSTALLATIONS. PER 2016 CALIFORNIA BUILDING CODES. FINANCIAL •• • DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 QTY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 SMI - RESIDENTIAL DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER EA ADDITIONAL 101-0000-42400 0 $52.01 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER EA ADDITIONAL PC 101-0000-42600 0 $39.01 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $104.55 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600. 0 $102.99 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: .$298.56 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.98 Total Paid for STRONG MOTION INSTRUMENTATION SMI:. $0.98 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE, 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $S.00 l in. City Of - i s Quinta Buikling 8t Safety Division P.O. Box 1504, -78-495 Cage Tampico ta.Quinta, CA 92253 -:(760) 777-7012 GC11 Building Permit Application and Tracking Sheet Perinit # 6 PAi )J�>t 1 Project Add tess: �j?j- 7 A�IENiAA Owner's Name:. �pq�g �o�=CitEi2. A. P. Number.' j-1}- _ t7 3 Address: �3� �Ji�0. Ma►.1 C .d tCz� StiNT� no-.ue�i7a Legal Description: w.—T= 2` vl ►cb 196 e r vAc, !City, ST, Zip: Com. 9-2 Contractor. T u^ CC Telephone. Address:` X-2 ProjectDescription: 2 _ �4ZTNI�D City, ST, Zip: L P,-QU 1tS'j(�. °5 221j �rL�.l1VLl1.lU M V�iC ��� Telephone:—](,,-O AA-2, 4—i08 -)k%,Z. State Lic. # : )3383G City Lic, #; (o 2 . 2i g 6 12 Arch., Engr., Designer e } 44- Address: City., ST, Zip: Telephone: Construction Type: o .panty: Project type (circle one)• New) Add'n Alter Repair Demo Sq. Ft.�� a" T° # Stories: #Units: State Lic. #: Name of Contact Person:D QgE-L�, Telephone # of Contact Person�10 411 7Qg Estimated Value of Project: �( APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd ' Reed TRAC MG PERM[r FEFS- Plan Sets Plan Check submitted item Amount Strgcturai Cates. Reviewed, ready for corrections Plan Check Dgwsit. . Truss Cala. . Caged Contact Person Pian Cheek Balance Title 24 Calci. Pians picked upCoastrucdon• Flood plain plan Plans resubmlfted.*. Mechariieal Grading plan 2'! Review, ready for correctionsfusve Electrical Subcoatsctor List Called Contact Person Plumbing Grant Deed Plana picked up ML H.O.A. Approval Plans resubmitted Gradlug IN HOUSS:- '1Q Review, ready for torrectionsilssae Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. YVb. Appr Date of permit Issue School Fees Total PermitFees '7�—I A C C KTRA7G-W : L-t� coal-czU e,7loKk 9vc� DAC- P-%�SSELL \6`sw-dt4 � QP4)pog;E g�lj�-T gru owta�R-'• J�M�S�c.o �`i��82 , 4 2"x 2 L A--{'T►CE CITYF E:)e�-�.A792 BUILD ]G- - APPROVE 5v cio FOR CON T UCTIO DA \lei IT\m .A i I i A k _. -.c::.,...:;=:,.•:.:____.. a =-:. _ ..�..�:..:..,,: - -- - i . PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. I I POINT OF CONTACTS GENERAL NOTES I INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW: CONTRACTORS: PLEASE CONTACT DURALUM BUILDING DEPARTMENTS: PLEASE CONTACT 4STEL ENGINEERING HOME OWNERS: PLEASE REQUEST ANY INFORMATION THROUGH YOUR CONTRACTOR 26030 ACERO SURE 200 PHONE: (V49)30S-11S0 MISSION VIEJO. CA 92691 FAX (949) 305-1420 STRUCTURAL ENGINEER OF RECORD: DUSTIN K ROSEPINK SE 5685 POINT OF CONTACT: MARIE -DOMINIQUE SETA, SE S987 I DESIGN PARAMETERS GOVERNING CODES: THE DESIGN OF ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE 2012015 INTERNATIONAL BUILDING AND RESIDENTIAL CODES, 201312016 CALIFORNIA BUILDING AND RESIDENTIAL CODES, ASCEISEI 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AND THE 2015 ALUMINUM DESIGN MANUAL- ' COLUMNS BEARING ON CONCRETE SLAB IS IN ACCORDANCE WITH 2012015 IRC AND 201312016 CRC SECTION AH105.2 FOR 10 PSF RESIDENTIAL CONSTRUCTION AND ACI 316-14 FOR 20,25 AND 30 PSF RESIDENTIAL AND CQMhJERCIAI, CONSTRI Ir..TInN ' 1. IN HFbIUI:N I IAL APPLICAYIONS: CRC AND IRC APPENDIX H, CBC AND IBC CHAPTER 16, CBC & IBC APPENDIX CHAPTER 1. ROOF LIVE LOAD: 10 PSF (20 POUNDS PER SQUARE FOOT AND GREATER MAY BE USED FOR COMMERCIAL APPLICATIONS AND RESIDENTIAL CARPORTS). ROOF SNOW LOADS: 10, 20, 25, 30,40 & 50 PSF (SNOW LOADS AT GROUND LEVEL). 2. IN COMMERCIAL APPLICATIONS: CBC AND IBC CHAPTER 16. ROOF LIVE LOAD: 20 PSF. ROOF SNOW LOADS: 20, 25, 30, 40 & 50 PSF (SNOW LOADS AT GROUND LEVEL). WIND SPEED DESIGN PARAMETERS: THE BASIC WIND SPEEDS CONSIDERED IN THIS REPORTARE 110,120,130 MPH, EXPOSURES B AND C (BASED ON THE CBCnBC). FOR USE WITH THE 201220113 CRCARC, DIVIDE THE REQUIRED CRCIIRC WIND SPEED BY SQRT(0.6). CBC I IBC WIND SPEED I 110 MPH 120 MPH 130 MPH EQUIVALENT CRCARC WIND SPEED I 85 MPH 93 MPH 101 MPH EXAMPLE: IF CRC/IRC WIND SPEED IS 85 MPH, THE PATIO COVER CONSTRUCTION SHALL BE BASED ON 85 MPH/ SORT(0.6) =110 MPH. SNOW LOADS DESIGN PARAMETERS: 1. R IS THE RESPONSIBILITY OF THE CONTRACTOR FOR THIS PROJECT TO VERIFY SNOW LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTION. TABULATED SPANS FOR SNOW LOADS HAVE BEEN ADJUSTED FOR ROOF APPLICATIONS. 2. WHERE SNOW LOADS OCCUR, THE CONTRACTOR FOR THIS PROJECT SHALL VERIFY WITH THE LOQAL AUTHORITY HAVING JURISDICTION WHERE DESIGN FOR SNOW DRIFTING I OR SLIDING IS REQUIRED PER ASCE 7-10, SECTION 7.7 AND 7.8. 3. DESIGN FOR SNOW DRIFT AND SLIDING HAVE BEEN CONSIDERED IN THIS SET OF DRAWINGS FOR ATTACHED COVERS WITH GROUND SNOW LOADS OF 30 PSF OR LESS. WHERE .SNOW LOADS DRIFTING AND I OR SLIDING OCCUR REDUCTION FACTORS PER SHEET S21 OR L2.1 SHALL BE APPUED TO THE STRUCTURE. 4..DESIGN FOR SNOW DRIFT AND SLIDING FOR DETACHED COVERS AND FOR ALL COVERS WITH GROUND SNOW LOADS HIGHER THAN 30 PSF IS BEYOND THE SCOPE OF THIS REPORT 'AND REQUIRES SITE SPECIFIC ENGINEERING. SEISMIC LOAD DESIGN PARAMETERS: SEISMIC DESIGN BASE SHEAR 17 POUNDS PER LINEAR FOOT PER WIDTH OF COVER, CONSIDERING THE FOLLOWING DESIGN PARAMETERS: 1. SITE CLASS: D 2. SEISMIC DESIGN CATEGORY: E 3. MAPPED SPECTRAL RESPONSE COEFFICIENTS: Ss =1.50, SI = 0.6. SAS =1.0, SDI = 0.50 4. RESPONSE MODIFICATION FACTOR, R=1.25 5. RISK CATEGORY II 6. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE IN COMPLIANCE WITH ASCE 7-10 SECTION 12.8.1.3. AS A RESULT, THIS SET OF PLANS CAN BE USED AT ANY SITE WITH Ss> 150, CONSIDERING SS =1.50. 1 OTHER DESIGN PARAMETERS: 1. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBC SECTION 1605.3.1. 2. THE FREESTANDING AND ATTACHED COVERS NOTED HEREIN ARE DESIGNED AS'OPEN STRUCTURES,' IN ACCORDANCE WITH ASCE/SEI 7. 3. FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL UNLESS SPECIFICALLY DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER 4. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF ASSEMBLY IN ACCORDANCE WITH SECTION CBC 15052, EXCEPTION 2. 5. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCEISEI 7, SECTION 26.2. 6. ALL APPUCABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE DESIGN ASSUMPTIONS: 1. LEAST BUILDING WIDTH OF MAIN STRUCURE: 30' 2. BUILDING HEIGHT OF MAIN STRUCTURE (MEAN ROOF HEIGHT} 20' MIN 3. MINIMUM COVER PROJECTION IS 10. 4. MINIMUM COVER SIZE ATTACHED TO MAIN STRUCTURE OR FREESTANDING: 10' x 10' 5. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DECK: SEE DETAIL 1BIS3.2 6. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH OURAPANEL- SEE DETAIL 1AIS3.2 7. MINIMUM SIZE OF EXISTING ROOF OVERHANG IS 50 SQUARE FEET, WHERE COVER IS ATTACHED TO THE EXISTING OVERHANG. B. THE RATIO (WP), COVER MEAN ROOF HEIGHT (H, FT.) DIVIDED BY COVER PROJECTION OR WIDTH (P, FT), SHALL NOT EXCEED ONE (1). 9. THE RATIO (UP), COVER LENGTH (L, FT.) DIVIDED BY THE COVER PROJECTION OR WIDTH (P, FT), SHALL NOT BE LESS THAN ONE (1). 10. THE'LENGTH OF STRUCTURE' SHALL BE TAKEN AS THE CONTINUOUS DISTANCE MEASURED ALONG THE EXISTING BUILDING WALL FROM ONE END OF PATIO COVER SUPPORT BEAM TO THE OTHER, INCLUDING ANY BEAM SPLICES. THE STRUCTURE LENGTH SHALL BE DETERMINED THIS WAY REGARDLESS OF ROOF COVERING TYPE. INCLUDING COMBINATION ROOFS WITH BOTH TRELLIS AND DECK ROOF USED ON THE SAME CONTINUOUS PATIO COVER STRUCTURE. HOWEVER, OPEN LATTICE PORTIONS OF THE STRUCTURE SHALL NOT BE COVERED BY ROOF DECK PER IAPMO 195. 11. PATIO COVERS WITH SOLAR PANELS ON THE ROOF: CONTACT DURALUM PRIOR TO ORDERING THE PART AND SUBMITTING DRAWINGS TO LOCAL AUTHORITY HAVING JURISDICTION. 12. CALCULATIONS FOR MAXIMUM SPANS WHEN ATTACHING TO AN EXISTING ROOF OVERHANG, AS SHOWN ON TABLE 1 ON S6.1 AND/OR L6.1, ARE ASSUMING THAT THE EXISITNG WOOD RAFTERS OR TRUSSES ARE DOUGLAS FIR -LARCH ND2. THIS TABLE CAN ALSO BE USED FOR OTHER WOOD SPECIES WITH Fb t 900 psi AND Fv t 180 Psi. DRAWING NOTES: 1. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED, AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 2. THE APPROVED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE JOB SITE AND SHALL BE AVAILABLE TO THE AUTHORIZED REPRESENTATIVES OF THE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE ORDER MATERIAL SPECIFICATIONS: 1. ALTERNATE ALUMINUM ALLOYS MAY BE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION AND HAVE EQUAL OR GREATER YEILD AND ULTIMATE STRENGTHS 2. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 POUNDS PER SQUARE INCH. 3. EMBEDDED STEEL MEMBERS SHALL BE HOT -DIPPED GALVANIZED, AND CONFORM TO A500 GRADE B. ROLL FORMED STEEL MEMBERS SHALL CONFORM TO A653 -SS (STRUCTURAL STEEL) GRADE 50 G60. 4. BOLTS: ALUMINUM BOLTS SHALL BE 2024-T4; STEEL BOLTS SHALL BE ASTM A-307. ALL BOLTS SHALL HAVE STANDARD -CUT PLATED WASHERS. 5. SCREWS: ALL SCREWS ARE SELF DRILLING (SDS) OR SHEET METAL SCREWS (SMS) IN CONFORMANCE WITH ICC -ES ESR 1976, ICC -ESR 3006, OR APPROVED EQUAL B. FASTENERS TO WOOD: WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION. 7. POST -INSTALLED ANCHORS: POST4NSTALLED ANCHORS USED SHALL BE SIMPSON STRONG TIE STRONG BOLT 2, STAINLESS STEEL (ICC -ESR 3037) OR EQUAL B. ALL COMPONENTS MANUFACTURED OR SUPPLIED BY DURALUM AND DESCRIBED IN THIS DOCUMENTS ARE INTERCHANGEABLE, PROVIDED THEY ARE SELECTED APPROPRIATELY TO SUPPORT THE LOADING THEY ARE SUBJECT TO. 9. THE SELF WEIGHT OF THE PATIO COVER COMPONENTS IN THIS REPORT CAN BE CALCULATED FROM THEIR SECTION PROPERTIES. THE SQLID COVERS VARY IN WEIGHT FRnM ARnI IT t Dcc TO PROLrT 2 PCr, 10. ROOF INSULATED PANELS (WHERE OCCURS} SEE S32 FOOTINGS: 1. ALL NEW CONCRETE FOOTINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED SOIL OR CERTIFIED FILL 2. DESIGN VERTICAL SOIL BEARING PRESSURE IS 500 POUNDS PER SQUARE FOOT. 3. DESIGN LATERAL SOIL BEARING PRESSURE IS 200 POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS 100 PSFIFT x 2 PER TABLE 18062 AND SECTION 18063.4). 4. ATTACHED COVERS FOR RESIDENTIAL USE MAY BE SECURED TO AN EXISTING CONCRETE SLAB PROVIDED THE SLAB IS AT LEAST 3112 INCHES THICK AND IS LOCATED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. THE SLAB SHALL BE A MINIMUM 10'-0- WIDE BY THE MAXIMUM COLUMN SPACING MEASURED AT THE COLUMN AND SHALL NOT CONTAIN ANY CRACKING FOR SNOW LOADS OF 25 PSF AND ABOVE. THE DISTANCE FROM COLUMN TO SLAB EDGE SHALL BE 6' MINIMUM. 5. A MAXIMUM COLUMN LOAD OF 750 POUNDS IS PERMITTED FOR ATTACHED COVER COLUMNS BEARING ON EXISTING OR NEW CONCRETE SLABS. NOTES TO LOCAL AUTHORITY HAVING JURISDICTION AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL USE OF THIS SET OF PLANS FOR A SITE SPECIFIC PROJECT: 1. EACH PROJECT SUBMIT-fED TO THE LOCAL AUTHORITY HAVING JURISDICTION MAY INCLUDE ONLY THE PERTINENT SrrE-SPECIFIC STRUCTURAL COMPONENTS LOCATED WrrHIN THiS U;pMO 115TED EVALUATION REPORT. 2. ALL ITEMS PERTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEL, HEADER SPAN, COLUMN SIZE, ETC.) SHALL BE CIRCLED AND CLEARLY IDENTIFIED. 3. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG INDICATING THE NAME AND ADDRESS OF THE MANUFACTURER DESIGN LOADS AND ENCLOSABILITY. 4. A WET STAMP FROM 4STEL ENGINEERING IS NOT REQUIRED ON THOSE PAGES FROM THE IAPMO REPORT. 5. A COLOR COPY OF THOSE PAGES FROM THE LAPMO REPORT IS NOT REQUIRED. ATA MINIMUM, SUBMISSION FOR A BUILDING PERMIT MUST INCLUDE THE FOLLOWING INFORMATION FROM THIS EVALUATION REPORT. I. TITLE SHEET AND GENERAL NOTES, GOA 2. STRUCTURAL CONFIGURATION (i.e. SOLID OR LATTICE ROOF, FREESTANDING OR ATTACHED). S1x OR L1.x 3. BASED ON THE REQUIRED DESIGN LOADS, SFTESPECIFIC RAFTER AND10R PANEL SPAN TABLES. 4. TYPE OF HEADER, POST TYPE & QUANTITY, FOOTING SIZE (WHERE REQUIRED) BASED ON THE SITE-SPECIFIC DESIGN LOADS. 5. APPROPRIATE STRUCTURAL DETAILS. 6. OTHER DOCUMENTATION THAT MAY BE REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 7. SEE S1x OR L1x FOR SHEET INDEX. JOB NAME: JOB ADDRESS: WIND LOAD: ` LIVE I SNOW LOAD: SEE SHEET S1.x OR L1.x FOR SHEET INDEX ALL UNUSED SHEETS SHALL BE REMOVED FROM THIS SET OF DRAWINGS. I SHEET INDEX OF & 13UILDIN 0� C rCON DATED"�`I7 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500. Q�FESS 1(� S5885 r qTF OF DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL QUIN PA FETY D . vE UCTION ON i DESCRIPTION 4STEL JOB A DATE 04/05!77 V DRAWN BY RER CHECKED M IAPM0195 V 2.0 TITLE SHEET, DESIGN LOADS, - GENERAL NOTES s G0.1 m p • � � 1 (E) BUILDING " ~ SOLID ROOF PANEL' SEE NOTE 2 ' 4 (E) BLDG. . SLOPE S N0 2 r -- EXT. BEAM SEE NOTE 3 TABLE 1 MINIMUM NUMBER OF POSTS REOUfRED • WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG I i ! 1 SOLID COVER CONNECTION TO BLDG SEE' NOTE' 2 WIND SPEED AND EXPOSURE NOTES' C> I I 110C 1 1205 1200 1308 Z w ' ' 2 2 2 3 N I i I I I I ' COL TIP I I aN U U z w � z 3 3 3 3 i I SEE JNOTE,4I'' T o o z I I SOLID COVER CONNECTION I TO BEAM SEE NOTE' 2 4 W a 3 I 4 5 - ~ SOLID ROOF PANEL' SEE NOTE 2 ' 4 (E) BLDG. . SLOPE S N0 2 r -- EXT. BEAM SEE NOTE 3 TABLE 1 MINIMUM NUMBER OF POSTS REOUfRED -SOLID • WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG ~- WIND SPEED AND EXPOSURE NOTES' WIDTH 1108 : 110C 1 1205 1200 1308 13DC 6 2 2 2 3 3 3 6 2 3 3 3 3 4 T 2 3 3 4 3 4 8 3 3 3 4 4 5 9 3 4 4 4 4 5 10 3 4 4 5 5 6 11' 4 4 4 5 5 6 17 4 5 5 6 5 7 - v WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED - TRIG WIND SPE D AND EXPOSUR FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO . WIDTH 110B 11DC 1 1208 12DC I 1308 1300 S 2 2 2 22 3 6 2 2 2 3 3 3 T 2 3 3 3 3 41 6. 2 3 3 4 3 4 9 3 3 3 11 A SEE SHEETS S4.1 &S4.2 FOR BEAM PROFILES. '� - 5 1Q 3 4 4 4 4 5 11' 3 4 4 FACTORS DUE TO DRI TAND SLIDING ` C. BEAM OVERHANG ; OH' SHALL NOT EXCEED - 25%; OF BEAM'S ADJACENT CLEAR SPAN. LOADS. S3.1A- SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND 4 45- E SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. MINIMUM FASTENERS -SOLID ~- LCONCRETE NOTES' BEAM OH BEAM CLEAR SPAN BEAM CLEAR SPAN o z �1 J SLAB, SEE NOTE 5 - STS SHOWN INTHIS, TABLE IS A MINIMUM. AM 1 NUMBER OF Q 'MAX SEE NOTE 1 ; Z _ POSTS AS RE. I EDTO ENSU E THATTHEPPOSTSPAGNG • w o W - 2- (SPANJ' SHOWN ON SHEETS SSxx.z OR LB.xx.x IS NOT E)CEEDED. N CONCRETE FTG,` -' LENGTH 'L' SEE NOTE 1 _ BEAM OH SEE NOTE 5' TYP_ 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 31S6.3 - SEE NOTE 1 • _ Y ' OR 3ft8.3. „ • - v 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED - , FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO . - - �_ _s - _ . _ _ ,.. • ' THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR U13. I , PLAN VIEW ISOMETRIC VIEW -Y TABLE 1 - MINIMUM - - A C^ 1/16•=1'-0" B 3/32•=1'-D° NUMBER OF COL REQ. N0"4" 1. PATIO /COVER, DIMENSIONS '�- .`► 3. SEAMS, f SHEET INDEX - SOLID PANEL STRUCTURES: TYPE A Y • A.IENGTH7OFSfRUCTUL' RE -SHAtL�NOT i8E LESS;.THAN EFTS -PROJECTION 'V. SEE DESIGN A SEE SHEETS S4.1 &S4.2 FOR BEAM PROFILES. '� GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES ASSUMPTION�'NeOTEIi10' FOR�PATIO COVERS'CONSISRNG OF SOUD COVERS AND LATTICE B. SEE SHEET S4.2 FOR FAN BEAM WHERE OCCURS. L S1.1- SOLID PANEL STRUCTURES: TYPE A FRAMING. P ' '� r ' +Q !N 7 fr, 1f, , i C. SFE SHEETS STI AND S8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. S21 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION B. 'HEIGHT OF STRUCTURE,;H`�(TO TOP OF -COVER) SHALL' -NOT BE OVER 12 FT. D. SEE SHEET S2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW FACTORS DUE TO DRI TAND SLIDING ` C. BEAM OVERHANG ; OH' SHALL NOT EXCEED - 25%; OF BEAM'S ADJACENT CLEAR SPAN. LOADS. S3.1A- SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND EXCEPEION=sNO;OVERHANG�ALLOWED AT•I BEAMS CONNECTED TO SIDE OF COL E SEE SHEETS S6.x FOR BEAM CONNECTIONS & DETAILS. MINIMUM FASTENERS D. SOUD COVER OVERHANG -'6k ti LL NOT EXCEED'! 25% OF BOTH DECK & IRP SOLID F. SEE SHEETS S5.1 AND S6.3 FOR BEAM SPLICE DETAIL WHERE REQUIRED. BEAM SIMPLE S3.2- SOLID PANEL STRUCTURES: CROSS SECTIONS - COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). SPLICE, WHEN NEEDED, SHALL BE LOCATED IMMEDIATELY ABOVE,,AN INTERIOR COLUMN. NO S4.1 - SOLID PANEL STRUCTURES: BEAM PROFILES E. `TRIBUTARY WIDTH ARE AS .SHOWN ON PLAN: BEAM SPLICE SHALL BE PERMfTTED BETWEEN COLUMNS OR ON TOP OF AN EXTERIOR S42 - SOLID PANEL STRUCTURES: BEAM PROFILES a` ; r COLUMN. S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES " • TRIG' (Bext)= Yt`ADJACLMT, DECK `CLEAR• SPAN @ RIGHT*f^1. S4A - SOLID PANEL STRUCTURES: MEMBERS PROFILES - + DECK OH @ LEFT "� ^ - �, • t 4. COLUMNS i' t.` S4.5 - SOLID PANEL STRUCTURES: CONNECTORS • • TRIB (BLDG)=Y2 ADJACENT DECK CLEAR, SPAN 1 S5.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS • ` 1 A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON r S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT,TO EXISTING BUILDING 2. SOLID COVERS - COVER DIMENSIONS. " ' S6.2 - SOLID PANEL STRUCTURES: CONNECTION DETAILS 7 - B. SEE SHEET S4.3 FOR COLUMN PROFILES.' S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS - y A SEE SHEET S11A FOR DECK PROFILES AND MAXIMUM SPANS. C. SEE SHEETS S7.1 AND S8.xx.x FOR TABLES SHOWING MAXIMUM f?OST SPACING. S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS - `� B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS- " t S7.2- SOLID PANEL STRUCTURES: FOUNDATION DETAILS S8-VLX SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx SPANS. - C. SEE SHEET S2 1 FOR REDUCTION OF SOLID_ COVER MAXIMUM SPAN WHEN DESIGNING FOR 5. FOUNDATIONS ark PSF LUSL, IXO MPH -� SNOW LOADS • "''''�_ (.- -.,, - •-- . - L - G9.1 -ADDITIONAL STATE LICENSURE STAMPS D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTINGBEAMS.n' .: ,� A� SEE SHEET S7.1 `FOR'COLUMN CONNECTION' TO FOUNDATION: -- -- 4_ E. SEE SHEETS S3.2&S6.1 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x`FOR MINIMUM FOOTING' SIZE- FOR PATIO. COVER; .":'r. - ; •--. F. MINIMUM SLOPE OF SOUD DECK COVERS TO BE PER SHEET S3.2. _ SUPPORTED ON CONCRETE FOOTING, WED ON BEAM SPAN SELECTED. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. r C. SEE STI FOR ALTERNATE FOOTING SIZES. RADE D. SEE 8/57.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE- rSOLID PANEL STRUCTURE TYPE A: ATTACHED SING LE'SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST-, CORONA, CA 92880 951.736.4500 DATE SIGNED: April 5, 2017 n - EA,c;/fvEEAWa 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AW APPROVAL REVISIONS MARK DATE DESCRIPTION ' r r 4 STEL JOB 4 16.1071 DATE 04105117 DRAWN BY • RER _ CHECKED' MDS - ' IAPMO'195` ` V 2.0's --�' SOLID PANEL STRUCTURES: TYPE A S1.1, n m m z II (E) BUILDING RAFTER SEE NOTE 2 OH BEAM CLEAR SPAN BEAM CLEAR SPAN o TE 1 z LENGTH 'L' SEE NOTE 1 z w RFAN RAFTER CONNECTION t TO BLDG SEE NOTE 2 I I I I I ROOF OVERHANG OR MCK MASONRY WAI I I I I I I 1103 1100 1208 1200 C) Z w LATTICE @ 3- PR 6'I O.C. 5 2 2 2 3 SEF( NOTE 2 I a o 2 ! ) EDGE COL, i ! w w w w a 7 2 I I I I SqNOTE 4 cr 4 W C 3 3 3 4 4 w I RAFp CONNECTION I ! I BEAM SEE NOTE 3 i i TO BEAM i EE NOTE 2 I � 3 CL 4 OH BEAM CLEAR SPAN BEAM CLEAR SPAN o TE 1 z LENGTH 'L' SEE NOTE 1 z w RFAN ! C FLAN VIEW ISOMETRIC VIEW B 3/32'=1'-0° I NOTES: 1. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 257 OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN, OR 24' MAX. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF LATTICES ADJACENT SPAN, OR 24' MAX. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= Xt ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (BLDG)=1 ADJACENT DECK CLEAR SPAN 2. LATTICE COVERS A. SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEETS 1.3.1A & L3.iF FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7.1 & LSxx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. k D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. _FOUNDATIONS t;."t ;rh A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING -SIZE' FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTEU::' C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/L7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE t TRIB ROOF OVERHANG OR MCK MASONRY WAI ! C FLAN VIEW ISOMETRIC VIEW B 3/32'=1'-0° I NOTES: 1. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 257 OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN, OR 24' MAX. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF LATTICES ADJACENT SPAN, OR 24' MAX. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= Xt ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (BLDG)=1 ADJACENT DECK CLEAR SPAN 2. LATTICE COVERS A. SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEETS 1.3.1A & L3.iF FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7.1 & LSxx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. k D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. _FOUNDATIONS t;."t ;rh A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING -SIZE' FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTEU::' C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/L7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB I WIDTH 1103 1100 1208 1200 TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE'MAX POST SPACANG (SPANT SHOWN ON SHEETS S&xx-.x OR LB.xxx IS NOT E)2:EEDED. 2 THIS TABLE IS TD BE USED W CONJUNCTION WITH DETAIL 31SR3 OR 3/L6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHET ICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. (�)=MBE'R - MINIMUM OF COL REQ SHEET INDEX - LATTICE STRUCTURES: TYPE E GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES 1-1.1 - LATTICE STRUCTURES: TYPE E 1-2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING 1-31A - LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 -LATTICE STRUCTURES: ATTACHMENTTO EXISTING BUILDING L62 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES CONNECTION DETAILS L7.1 - LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8.w(.X - LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LL/SL, 1X0 MPH 39.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE E: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� Q S5885 m TF OF CALYFc� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 *U APPROVAL RE<'ISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16.1071 DATE 04/017 DRAWN BY RER CHECKED MDS IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE E L1.1 i WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB WIND SPEED AND EXPOSURE WIDTH 1103 1100 1208 1200 130B 1300 5 2 2 2 3 3 3 6 2 3 3 3 3 4 7 2 3 3 4 •3 4 6 3 3 3 4 4 5 9 3 4 4 4 4 5 1Q 3 4 4 5 5 6 11' 1 4 4 4 5 5 6 17 1 4 1 5 5--j 6 1 5 1 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED AND EJPO.SURE WIDTH 1108 1100 1208 12DC 1308 1300 S 2 2 2 2 2 3 6 2 2 2 3 3 3 7 2 3 3 3 3 4 a C 3 3 _ ...4 .., 9 3 3 3 . 4 4 5 7l7 3 4 4 4 4 5 11' 3 4 4 5 1 5 6 17 1 3 1 4 4 5 3 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE'MAX POST SPACANG (SPANT SHOWN ON SHEETS S&xx-.x OR LB.xxx IS NOT E)2:EEDED. 2 THIS TABLE IS TD BE USED W CONJUNCTION WITH DETAIL 31SR3 OR 3/L6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHET ICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR L6.3. (�)=MBE'R - MINIMUM OF COL REQ SHEET INDEX - LATTICE STRUCTURES: TYPE E GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES 1-1.1 - LATTICE STRUCTURES: TYPE E 1-2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING 1-31A - LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 -LATTICE STRUCTURES: ATTACHMENTTO EXISTING BUILDING L62 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES CONNECTION DETAILS L7.1 - LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8.w(.X - LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LL/SL, 1X0 MPH 39.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE E: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS I(� Q S5885 m TF OF CALYFc� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 *U APPROVAL RE<'ISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16.1071 DATE 04/017 DRAWN BY RER CHECKED MDS IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE E L1.1 i (E) BUILDING rRAFTER SEE NOTE 2 I ! WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) I i 1 j RAFTER CONNECTION CL N TRIB i TO BLDG SEE NOTE 2! I cr I E 1 I I • J 1100 120B 1200 1308 1300 5 2 2 2 3 3 I j LATTICE @'3" OR 6" O.C.a 6' 2 i ! I SEE NOTE .2 3 o 1 j i j /-71 EDGE COLI I 2 U m RAFTER CONNECTION SEE NOTE '4 cr a TO BEAM SEE NOTE 21 3 3 4 4 5 3 3 SEAM OH BEAM CLEAR SPAN BEAM CLEAR SPAN o F E NOTE 1 w z w LENGTH 'L' SEE NOTE 1 vwi Ir� PLAN VIEW NOTES: I. PATIO COVER DIMENSIONS A LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN.. D. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= Ji ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (Bint)= J ADJACENT DECK CLEAR SPAN @ RIGHT + )i ADJACENT DECK CLEAR SPAN @ LEFT • TRIB (BLDG)=J4 ADJACENT DECK CLEAR SPAN 3 2. LATTICE COVERS A SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEETS L3.1A & L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS U5.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. ROOF OVERHANG OR WOOD, CONCRETE, BRICK MASONRY WALL SEE SHT. 8 RAFTER SEE NOTE 2- i -CONCRETE FTG, SEE NOTE 5, TYP TI., • "t 11Y �o� ISOMETRIC VIEW 0 '3/32•=1'-0° 3. BEAMS A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7.1 & LB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS Be DETAILS. 4. COLUMNS. A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/1-7.1 FOR ATTACHED PATIO COVER SUPPORTED -ON SLAB ON GRADE. 0 0 Z W w x x TABLE 1 MINIMUM NUMBER OF POSTS REQUIRED NOTES: 1. NUMBER OF POSTS SHOWN W THIS TABLE 6 A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE 'MAX POSTSPACING CONCRETE SLAB, (SPANT SHOWN ON SHEETS SB.xx.x OR LB.xx x IS NOT EXCEEDED. SEE NOTE 5 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 356.3 OR 311..6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR U5.3. A TABLE 1 - MINIMUM NUMBER OF COL REO. SHEET INDEX -LATTICE STRUCTURES: TYPE F GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L12 -LATTICE STRUCTURES: TYPE F L2.1 - LATTICE'STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION -FACTORS DUE TO DRIFTAND SLIDING L3.1A- LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 -LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L62- LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8_xxX- LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLISL, 1X0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE F:'ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER M:< y_. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS I( Cn W S5885 o' lq UCT� TF OF CAL t DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB >I 151071 DATE 04/05117 DRAWN BY RER CHECKED MDS IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE F L1.2 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB WIND SPEED AND EXPOSURE WIDTH 110B 1100 120B 1200 1308 1300 5 2 2 2 3 3 3 6' 2 3 3 3 3 4 T 2 3 3 4 3 4 B 3 3 3 4 4 5 3 3 4 4 4 4 5 10' 3 4 4 3 5 6 11' 4 4 4 5 5 6 12 1 4 1 5 1 5 6 5 1 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED AND EXPOSURE WIDTH 1108 110C 1208 12DC 1308 130C S2 2 2 2 2 3 6 2 2 2 3 3 3 T 2 3 3 3 3 4 If 2 3 3 4 3 4 9 3 3 3 4 4 5 10'3 4 4 4 4 5 11' 3 4 4 5 5 6 72 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN W THIS TABLE 6 A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE 'MAX POSTSPACING CONCRETE SLAB, (SPANT SHOWN ON SHEETS SB.xx.x OR LB.xx x IS NOT EXCEEDED. SEE NOTE 5 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 356.3 OR 311..6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PER S6.3 OR U5.3. A TABLE 1 - MINIMUM NUMBER OF COL REO. SHEET INDEX -LATTICE STRUCTURES: TYPE F GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES L12 -LATTICE STRUCTURES: TYPE F L2.1 - LATTICE'STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION -FACTORS DUE TO DRIFTAND SLIDING L3.1A- LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42 -LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1 - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L62- LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTICE STRUCTURES: FOUNDATION DETAILS L8_xxX- LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLISL, 1X0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE F:'ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER M:< y_. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS I( Cn W S5885 o' lq UCT� TF OF CAL t DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB >I 151071 DATE 04/05117 DRAWN BY RER CHECKED MDS IAPMO 195 V 2.0 LATTICE STRUCTURES: TYPE F L1.2 I V* ATTACHED COVER DESIGN ASSUMPTIONS GROUND SL, psf hd, ft. Lu = 20'-0" MAX. 25 34 hd = 0.043 (Lu)am (SL + IOP - 1.5 `30 1.43 MAXIMUM U he = 3'-6" MIN. > 30 NOT PERMITTED W=4hd=1-0" ATTACHED COVERS N.T.S. c , ) l 1 NOTE SED IN DESIGN THE MAXIMUM ALLOWABLE TABULATED SPANS FOR SOLD ROLL FORMED ROOF PANELS AND BEAMS USED IN THE CONSTRUCTION OF ATTACHED RESIDENTIAL AND COMMERCIAL COVERS MUST BE ADJUSTED PER TABLES 1 AND 3 WHEN DESIGNING FOR SNOW SLIDING AND/OR DRIFTING. I. i f i • �T .rte of i r SNOW LOAD DESIGN CRITERIA: DRIFT &SLIDING FREESTANDING COVER DESIGN ASSUMPTIONS IF S < 20' AND S < 6h, THEN SITE SPECIFIC ENGINEERING IS REQUIRED. IF S > 20' OR S > 6h, THEN NO SNOW DRIFTING AND/OR SLIDING NEED TO BE CONSIDERED. \FREESTANDING COVERS N.T.S. TABLE 3 TABLE 2 BEAMS SPAN REDUCTION FACTORS BEAM TYPE ATTACHED COVERS LATTICE RAFTERS SPAN REDUCTION RAFTER TYPE GROUND SNOW LOAD (psf) 25 30 40 50 7x61/2"20:24. 0.8 0.8 0.75 0.75 7'x61/7'x0.32" 0.85 0.8 0.75 0.75 2'x61!2"x0.42" 0.8 0.85 0.8 0.75 3"x8" 0.6 0.8 0.75 0.75 (2) 2"x6 1/2"x0.24" 0.85 0.8 0.8 0.8 (2) 2"x6 1/2"x0.32"0.85 0.8 0.85 0.85 (2) 2"x6 1/2"x0.42" 0.85 0.85 0.8 0,8 c , ) l 1 NOTE SED IN DESIGN THE MAXIMUM ALLOWABLE TABULATED SPANS FOR SOLD ROLL FORMED ROOF PANELS AND BEAMS USED IN THE CONSTRUCTION OF ATTACHED RESIDENTIAL AND COMMERCIAL COVERS MUST BE ADJUSTED PER TABLES 1 AND 3 WHEN DESIGNING FOR SNOW SLIDING AND/OR DRIFTING. I. i f i • �T .rte of i r SNOW LOAD DESIGN CRITERIA: DRIFT &SLIDING FREESTANDING COVER DESIGN ASSUMPTIONS IF S < 20' AND S < 6h, THEN SITE SPECIFIC ENGINEERING IS REQUIRED. IF S > 20' OR S > 6h, THEN NO SNOW DRIFTING AND/OR SLIDING NEED TO BE CONSIDERED. \FREESTANDING COVERS N.T.S. TABLE 3 ATTACHED COVERS BEAMS SPAN REDUCTION FACTORS BEAM TYPE GROUND SNOW LOAD (psf) 25 30 1 40 50 B7 61/2" GOLLTL-F RMED 0.85 0.8 0.8 0.8 B2 MAG BEAM 0.8 0.8 0.85 0.85 B3 4" I -BEAM 0.85 0.85 0.85 0.85 B4 MCr. rIyrrgR 0;0 0.0 0.0 u.6 BS 3" SO ALUM W/ 0.8 0.8 0.8 0.8 12 GA STL'U" CHANNEL B6 7" I -BEAM 0.85 0.85 0.85 0.85 B7 7" I -BEAM W/ 0.85 0.85 0.8 0.8 ONE 'C' SPUCE B8 7° I -BEAM W/ 0.85 0.8 0.8 0.8 TWO'C SPLICES B9 (2) 2 x 6 1/2 x 0.042 0.8 0.8 0.75 0.75 B10 (2) 2 x 6 112 x 0.032 0.8 0.8 0.8 0.75 B11 3 x 8 0.75 0.75 0.7 0.7 B12 (2) 3 x 8 0.8 0.8 0.75 0.7 B13 3x8W/ 0.8 0.8 0.8 0.8 14 GA. STEEL INSERT B14 3 x B W/ 0.85 0.85 • 0.85 0.85 12 GA. STEEL INSERT B15 (2) 3 x 8 W/ 0.85 0.85 0.85 0.8 14 GA. STEEL INSERT B16 (2) 3 x 8 W/ 0.8 0.8 0.8 0.85 12 GA. STEEL INSERT 7 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 1pFESS I qyq K S5885 r T �P 9TF OF CAl-\F DATE SIGNED: April 5, 2017 //% TCL,;L_ M vo111e/=R11vo 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL j - REVISIONS MARK DATE DESCRIPTION 4 STEL JOB A ' 161071 DATE 04!06/17 DRAWNBY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT & SLIDING L2.1 A ALUM. ALLOY 30D H36 JALUM. ALLOY3004-H36 ALUM, ALLOY 3004-1-136 r • it �, ( T � T o . T o i c l ' I 2000' 4.000' 2.000" t `\ z.000' . MAX 3.000" n, l 3' x 8' RAFTER R2 2' x 6 S RAFTER RS DBL 2' x 6.5' RAFTER f 3x8 RAFTER. -ATTACHED STRUCTURE 2X6 12 RAFTER -ATTACHED STRUCTURE DBL. 2c612 RAFTER -ATTACHED STRUCTURE LUSL T-.. ON) SPACING WIND SPEED / E)P LUSL T ON) SPACING O/C 110B WIND SPEED / EXP 110 C 120 B 120 C 130 8 130 C LCL T Q SPACING O/C 110 B WIND SPEED / EXP 110 C 120 B 12Q C 1308- 130 C O/C 11013 110C 120 B 120 C 130 B 130 C 10 0.042 16' 29'-8' 29-6' 29'-8' 28'-9' 29'-3' 26'-3" 10 0.02424' 16' 16'-0' 15-10' 16'-0' 16-0' 15'-9' 13-8' 10 0.024 16' 2T-6' 27-4' 27-6' 21'-1' 22-2' 19-2' 24' 24'-2' 24'-1' 24'-Y 23=6' 24'-0' 21'-6' 13'-1' 13'-0' 13'-1' 17-3' 12-10' 11'-2' 24' 18'-4' 18'-3' 18'-4' 1T-3' 18-2` 16-0' 20 0.042 16' 23-0' 23'-0' 23'-0' .23=0' 23'-0' 27-9' 0.032 16' 20-3' 20-2' 20-3', 19-8' 20-1' 18'-2'' 0.032 16' 28'-7' 28'-0' 28'-7' 2T-9' 28-3' 26-T 24' 18'-9' 18'-9' 18'-9' 18=9' 18'-9' 18'-9' 24' 16'-7' 16-6' .16'-7' 16'-1' 19-4' 14'-10' 24' 23'•+ 23'-3' 23'•4' 22-8' 23-1' 2Q-10' 25 0.042 16' 19-8' 19-8' 19-8' 178* 19.8' 19'-8' 0'042 16.' 24'-6' 24'-4' 24'-6' 23-9' 24'-3' 23'-2' 0.042 16' 34'-7' 34'-4' 34'-7' 33J' . 34'-2' 37-8.' 24' 16'-1' 16'-1' 16'-1' 16=1' 15-1- IV 1' 24' 20-1' 20-0' 20'-1' 19.6' 19-9' 19-0' 24' 28'-2' 28'-1' 28'-2' 27-4' 2T-10' 29-8- 3o 0.04216' 18'-1' 19-1' 18'-1' 18=1' 18'-1' 18'-1" 20 0.024 16' 174' 174' 17-4' 174' 17-4' 124' 20 0.024 16' 1T4' 1T4' 1T4'1 -r-4" 1T-4' 1T-3' 24' 13'-9' 13-9' 13'-9' 13'-9' 13'-9' 13'-9' 241. 10'-2' 1Q-2' 10'-2' 1Q-2' 10'-2' 10'-1' 24' 14'-2' 14'-2' 14'-2' 14'-2' 14'-Y 14'-2' 40 0.042 16' 75-10' 15-10` 15-10' 15-10' 15-10' 1S-1 D' 0.032 18' 15'-8' 15-8' 15'-e' 15'4' 15'-8' 15-8' 0.032 16' 27-1' 27-1' 22-1' 22-1' 22-1' 27-0' 24' 17-1' 17-1' 12-1' 17-t' 17-1' 17-1' 24' 12-10' 12-10' 12-10' 17-10' 17-10' 12'-9' 24' 18'-1' 18'-1' 18`-1' 10-1' 18-1' 19-W. 50 0.042 16' 13'4' 13 4-4' 13'' 13�" 13'4' 13'-4' 0' 2 16' 19-0' 19-0' 19-0' 19-0' 19-0' 18'-10' 0.042 16' 26'-8' 26'•8' 26'-8' 26'-8' 26'-B' 26'-7' 24' 10-3' 10-3' 10-3' 10'-3' 10'-3' 10'-3' 24' 15-6'- 15-6' 15-6' 15'-6' 151-6' 15-6' 24' 21'-10' 21'-10' 21'-10' 21=10' 21'-10' 21'-9' NOTE: IT IS ACCEPTABLE TO SUBSTITUTE:16' - (2) 3x8 @ 32 -OC IN LIEU OF (1) 3x8 Q I6 -OC - (2) 3x8 @ 48.00 IN LIEU OF (1) 3x8 Q 24 -OC - (2) 2x6 @. 32- OC IN LIEU OF (1) 2x6 Q 16.00 - (2) 2x6 Q 48'OC IN LIEU OF (1) 2x6 Q.24 -OC 25 0.024 16' 10-7' 10-7- 10'-7' 10-7' 10-T 10-7' 25 0.024 16' 15'-10' 15'-10' 16-10' 15-10' 15'-10" 15-10' 24' 8'-1' 8'-1' B-1' B -t' 8'-1' B-1' 24' 13'4' 1324' 13'4' 13-2' 13-3' 17.9' 0.032 4 16' 14'' 14'-4' 14'4 4' 14'' IV-V 14'4' 0.032 16' 20'-2' 20'-2' 20'-2' 20-2'2U-2' 20'-2' 24' 11'-1' 11'-1' 11'-1' 11'-1' 11'-1' 11'-1' 24' 16-7' 16-T 16-7' 16-7' 16-T 16-7' 0062 1T4' 1T4' 1T4' 1T4' 1T4' 1T4' 0.042 16' 24' 6' 24'-6' 24'-6' 24'-6' 24-6' 24'-6' 24' 13'-3' 13-3' 13'-3' 13-3` 13'-3' 13-3' 24' 20'-0' 20'-0' 20'-0' 20'-0' 20-0' 20'-0' 30 0.024 16' 29-8' 29-6' 29-8' 28'-9' 29-3' 26'-3' 30 0.024 16' 16=0' 15-10' 16'-0' 15-0' 13-9' 13'-0' 24 24'-2' 24'-1' 24'-2' 23'-6' 24'40' 21'-6" 24' 13'-1' 13'-0' 13-1 17-3' 17-10' 11'-2' 0.032 16' 23'-0' 23=0' 23-0' 23'-0' 23'- 0' 22 -9' 0.032 16' 20-3' 20`-2' 20'-3` 19-8' 2Q-1" 18'-2' 24' 18'-9` 18'-9' 18-9' 18-9' 18-9' 1 B'-9' 24'_ 16'-7' 1 B-0' 16'-7' 16'-1' 19•4' 14'-10' 0.042 16' 19-8" 19-8' 194' mr, 19'4' 19-8' 0.042 16' 24'-6' 24'4' 24'-6' 23-9' 25-3' 23'-2' 24' 16'-1' 16'-1' 16'-1' lew- 16'-1' 16'-1' 24' 20'-1' 20'-0' 20-1' 19-6' 19-9' 19-0' 40 0.024 16' 18'-1' 18'-1' 18'-1' 18-1" 18'-1' 19-1" 40, 0.024 16' 17-4' 174' 17-4' 17.4' 124' 174' 24' 13'-9' 13-9' 13-9' 13'-9' 13-9' 13-9' 24' tU-2' 1V-2' 10'-2' 10-2' 19-2' 1Q-1' 0.032 16' 15-10' 15-10' 15-10' 15.10' 1S-1 D- 1S-10' 0.032 16' 15 8' 158' 15 8' 15-8' 19-B' 15-0' 24' 17-1' 12-1' 17-1' 17-1' 17-1' 17-1' 24' 17-10" 17-10" 12-10' 17-10• 17-10' 12-9- 0.042 16' 13'4' 134.' 134' 134' 13'4' 13' 4' 0042 16' 190' 19-0• 19-0' 19-0' 140' 18-10' 24' 10-3' 10'-3" 103' 10.3' 10'-3' 10'-3' 24' 16-6* 15'-6' 15'-s' 1 S-6' 13-6' 15'-0' 50 0.024 16' 18'-1" 18'-1' 18'-1' 18'-1' 18'-1' 18'-1' S0 0.024 76' 10-11 10-T 10-T 1Q -T 10-7- 10-T 24' 13'-9' 13-9' 13`-9' 13'-9' 13'-9' 13-9' 24' 8'-1' 8'-1' 8'-1" 8=1' 8'-1' 8'-1' 0.032 16' 15-10' 15'-10' 1 10 5-10' 15-' 15-10' 15-10' 0.032 4'4' 16' 1 14'd' 14'4 4' 14'' tt4' 14' 4' 24' 17-1" 12-1' 17-1' 17-1' 17-1' 17-1' 24' 11'-1' 11'-1' 11'-1' 11'-1' 1T-1' 11'-1' 0.042 16' 134' 1 134' 13'4' 13'4' 13'-413' 4' 0.042 16' 1 T.4' 1 T4' 1 T4' 17'4' 174' 1 T4' 24' 10-3' 10-3' 10-3 10-3 10-3' 10-3' 24 1 13'-3' 13'3' 13-3' 13'-3' 13-W 133' =,essay 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESSlgyq� Louco S5 5 r T�tP �e- 9TF OF CAL \F DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 94 9.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB ✓1 161071 DATE 04M17 DRAWN BY RER CHECKED MDS "IAPMO 195 V 2.0 LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L3.1 A T . 3.000• Y x 8' RAFTER nt 3'=1 •-0• 1 ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 JALLIM. ALLOY 3004-H36 T o T c 2.000' 2.000' 4.000" 2.000' MAX l 5� i x8.6' RAFTER R3 DBL 7 x 6.5' RAFTER i 3x8' RAFTER- FREESTANDING STRLCTURE 2x6 12 RAFTER.- FREESTANDING STRUCTURE DBL_ 2x612 RAFTER- FREESTANDING STRUCTURE LL/SL T ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 JALLIM. ALLOY 3004-H36 T o T c 2.000' 2.000' 4.000" 2.000' MAX l 5� i x8.6' RAFTER R3 DBL 7 x 6.5' RAFTER i 3x8' RAFTER- FREESTANDING STRLCTURE 2x6 12 RAFTER.- FREESTANDING STRUCTURE DBL_ 2x612 RAFTER- FREESTANDING STRUCTURE LL/SL T SPACING WIND SPEED / EW LUSL T SPACING WIND SPEED / EXP- LL/SL T SPACING O/C 110 B WIND SPEED / EXP 110 C 120 B 120 C 130 B 130 C O/C 110B 110C 120 B 120 C 130 B 130 C O/C 1_10 -BT -110 C 120 B 120 C '_130 8 130 C 10 0.042 16' 253' 25-3' 2G-3' 26'-3' 26'-3' 25'-T 10 0 �4 16' 14'-2' 14'-2' 14'-2' 14'-2' s14' -Y 13'-9' 10 0.024 16' 19'-10' 19'-10' 19'-10' 19'-10' 19'-10' 14i' 24' 21'-0' 21'-6' 21'-6' 21-6' 21'-G' 21'-D' 24' 11'-7" 17'-7' 11'-7' 11'-7' '11'-T 11'-3' 24' 16'-3' 153' 15-3' 75-3' 16'-3' 15-10' 20 0.042 16' 21'-10' 21'-10' 21'-10' 21'-10' 21'-10' 21'-10' O.Qi2 16' 15-0' 15-0' 18'-0' 15-0', °y18-0' 17-7' 0.032 16' 25'-3' 25'3' 25'-3' 25-3' 25-3' 24'-8' 24' 1T-10' 1T-10' 1T-10' 1T-10' 1T-10' 1T-10' 24.' 14'-8' 14'-8' 14'-8' 14'-8'• _14'-8' 14'.{• 24' 20'-8' 2U-0' 20'-8' 20'-8' 20-8' 20'-2' 25 0.042 16" 21'-0' 21'-S" 21'-6' 21-2' 21'-3' 20'-8' 0'�Z 16' 21'-9` 21'-9' 21'-9' 21-9' 21'-9' 21'-2' 0 2 16' 30'-8' 37-8' 30'-B' 30'-8' 30-8' 29'-10' 24' 1T-7' 1T -T 1T -T 1T�' 1T b' 15-10' 24' -1T-9" 1T-9' 1T-9' 1T-9' :1T-9' 1T-3' 24' 25'-1' 25'-1' 25-1' 25-1' 23-1' 244' 30 6.042 16' 19,-1' 19-1' 19'-1' 19-1' 14-1' VY -1' 20. 0 �4 16' 11'-9' 11'-9' 11'-9' 11'-9' >11'-9' 11'-9' 20 0.024 16' 16'-7' 15-7' 16'-7' 15-7' 16-T 16'-7' 24' 1S-7' 16-7"15'=T 15-T 15'-7' 15'-7' 24' T-8' 9'-0' g-0' g-0' ,: g_B• g$. 24' 13'-7' 13'-7' 13'-7' 13'-7' 13-7' 13'-7' 40 0:042 16' 75-0' 15-8' 15-8' 16-8' 16'-0' 15-8' 0.032 16' 1S-0' 15-0' 16-0' 16-0' :.15'-0• 15-0' 0.032 16' 21'-1' 21'-1' 21'-7' 21'-1.' 21'-1' 21'-1' 24' 13'-0' 13'48' IT4r 13'--B' 13'$' 13'-8' 24' 17-3' 12-3' 173' 17-3'. -17-3' 17-3' 24' 1T-3' 1TJ' 1T-3' 1T-3' 17-3' 1T3' 50 0.042 16' 16-0' 1540' 151-0' 15'-0' 15'-0- 15'4r 0 �2 15' 18'-1' 18'-1' 75-1' 18'-1' .18'-1' 18'=1' 0.0421 16' 25'-V' 25'-6' 25'-6' 26-6'. 26-6" 24' 71'-2' 11'-Y 11'-Y 11-2' 71'-2' 11'-Y 24' 14'-9' 14'-9` 14'-9' 14'-9' 14'-9' 14'-9' .25.6' 24' 20'-10' 2P-10' 2P-10.' 20-10' 2Q-10' 2Q-10' NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: (2) 3x8 C 32'OC IN LIEU OF (1) 3x8 @ 16'OC (2) 3x8 Q 48'OC IN LIEU OF (1) 3x8 @ 24'OC (2)' 2x6 C 32 -OC IN LIEU OF (1) 2x6 @ 16'OC (2) 2x6 (i? 48'OC IN LIEU OF (1) 2x6 @ 24'OC \ 25 0.02416' 11'-T 11'-7' 11' T 11'-0'., 11'-6' 11'-2' 25 0.024 16' 16'-3' 153' 15-3' 15-1' 16-2' 15'-0' 24' 9'-6' 9'-6' 7-6' T-6' 9'-6' T-2' 24' 93' 9-3' 9-3" T-3' 93' 9'-3' 0.032 16' 14'-9' 14'-9' 14'-9' 14'-6" _14'-T 14'-2' 0.032 16' 20'-9' 2U-9' 20'-9' 20'-6' 20-T 19'-10' 24' 12'-1' 12'-1' 17-1' 11'-10' 17-0' 11'-7' 24' 17'-0' 1T-0' 1T-0' 16'-8' 16-9' 19 -3 - . 0042 76' 17-9' 1T-9' 17-9' 1T-7' ' 1T-8' 1T-1' 00,D4216' , 25'-1' 26-1' 25-1' 25'-1' 26-1' 25'-1' 24' 14'-T 14'-7' 14'-T 14'4'? • 14'-6' 14'-0 ' 24' 20-6' 20-0' 20-6' 20'-6' 20-6' 217-6- 30 0.024 16' 25-3' 25-3' 253' 253" '_25-3' 25'-7' 30 0.024 16' 14'-2' 14'-2' 14'-2' 14'-2' 14'-Y 13'-9' 24' 21.'-6' 21'-6' 21W 21'-0' 21'-6' 21'-0• 24' 11•-T 11'-T 11'-7' IT -T 1T -T' 11'3' 0.032 15' 21'-10' 21'-10' 21'-1D' 21'-10' .21'-10' 21'-10' 0.032 16' 18'-0' 18'-0' 1g-0' 1Q-0' 18'-0' 1T -T' 24' 1T.-10' iT-10' 1T-10' 1T-10'! 17-10' 1T-10'24' 14'-B• 14'-0' 14'-9' 14'-8' 14'-8' 14'4' 0.042 16' 2T-6` 2T-6' 21'-0' 21:-2>,' 21'-3' 20'-8' 0 �2 16' 27-9' 21'-9' 21'-9' 31'-9' 3T-9.' 21'-2' 24' 1T -T 17-7' 1T-7' 1T.-' : C IT -6' 15-10'24' 1T-9' 1T-9' 17'-9' 17-9' 17-9' 7T3' 40 0.024 16' 19'-1` 19-7' 14-1' 19-1.' ; ' 19'-1' I73-1'0.024 40 16' 11'-9' 11'-9' 11'-9' 11'-9' ' 7 T-9' 11'-9' 24' 15'-7" 15'-7' 15-7' 16-7': 15'-T 15'-T 24' S -s' 9'-8' 9'-8' 9-8' 9'-e' 9'-B' 0.032 16' 1 fi -8' 15-8' 15-8' iv -8.; i s,4r 15-6' 0.032 16' 16-0' 16-0" 15-0' 16-0' 1 S -D' 16-07 24' 13'-8' 13=8' 13`•8' 13-a' ; '13'48' 13'-8' 24' 12-3' 173' 17-3' 12'-3' 12-3' 173' 0.042 16' 15'40' 1S-0• 15'-0' 15-0'; 15'-0' 15-0' 0.042 16' 18'-1' 18.'-1' 18'-1' 18'-1' 18-1' 16'-1' 24' 11'-2' 11'-2' 11'-2' 71'-2' ' '11'-2' 11'-2' 24' 14'-9' 14'-9' 14'-9' 14'-9' 14-9' 14'-9' J 50 0.024 16' 19'-1' 19-1' 19'-1' 19'-1' ; 19'-1' 14-1' 500.032 0.024 16' 11'-7' 11'-T' 11'-7' 11'-6' 1 T-6' 11'-2' 24' 16-7- IT -7' 15'-7' 15-7' ; 15' T is-!* 24' 9r -w 9'-6' 9'-6' S. 6' 9'-0' 9'-2' 0.032 16' 15-8' 16'4" 15-e' 15-8". 15-8' 15-8' 16' 14'-9'. 14'-9' 14'-9' 14'-6' 14'-T 14'-2' 24' 13'-8' 13'-B' 13'-8' ix -8"; 13'-8' 131-8' 24' 77-1' 12'-1' 17-1' 71-10' 12-0' 11'-7' 0.042 16' 15'-0'- 1T,D" 1 15'-0' 15'-0'', 16-0' 1.5'-0' 0 �2 16' 1T-9' 1T-9' 1T-9' 1T-7' 17-8' 1T-1' 24' 1 11'-2` 11'-2' 1,1'-2' 11'-2' ; ' 11'-Y 7 t-2' 24' 1 14'-T 14'-7' 14'-7' 14'-4' 14-6' 14'-0' DURALUW 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ESS Iq�y Lou S5885 DATE SIGNED: April 5, 2017 �� TCL_ ENG 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHI APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 161071 DATE 04/05/17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: FREESTANDING COVERS RAFTER SPANS L3.1 F Im ALUM. ALLOY 3004-1-136 18' . 1 2' x 3• LATTICE TUBE 6°=1'-O" ALUM. ALLOY 3004 H36 0 0 0 0 0.016" voi N �cr 0 1.500" OR 2.000" I(��LMCE 2• SQ. OR 2' SQ. TUBE.., ALUM. ALLOY 3004-1-136 STEEL ASTM A653 -SS GRADE 50 G60 1.229° 0 o n CD m ca n N a 2.824" 3.000" 12 GA CONf1N000S STEEL INSERT 0.042"co 'aJ�s DURALUW 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Igy9� S588.5 gyp, �P l,9lF OF CpU`V DATE SIGNED: April 5, 2017 kmmNra/i'�EE.4/lvu 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 ��3• SQ. x 0.032' ALUM. BEAM W/ - "r 12 GA SM INSERT 3°=1'-0" ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 1360 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/- TYP. 0 m 3.000" 4.000" 3.000" MAX. DBL 3 SQ. x OD42 ALUM. BEAM W/ 14 GA STL INSERT 3"=v -o" ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 G60 ALUMINUM BEAM . .& CONTINUOUS STEEL INSERT PER B14/- TYP. 0 0 3.000" 4.000" 3.000" MAX. DBL 3 SQ. x 0-042 ALUM. BEAM " . W/ 12 GA STL INSERT 3"=1'-0° 3 x 8.x 0-042' ALUM. ALLOY 3004-436 ALUM. ALLOY 3004-H36 0.042° TYP. 0 • m 3.000" 4.000° 3.000" MAX 612 DBL 3.x820.042' 0 a m ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 G60 - - .- ( - C5 ALUM. ALLOY 3004-1-136 STEEL ASTM A653 -SS GRADE 50 G60 1.229° 0 o n CD m ca n N a 2.824" 3.000" 12 GA CONf1N000S STEEL INSERT 0.042"co 'aJ�s DURALUW 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�FESS Igy9� S588.5 gyp, �P l,9lF OF CpU`V DATE SIGNED: April 5, 2017 kmmNra/i'�EE.4/lvu 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 ��3• SQ. x 0.032' ALUM. BEAM W/ - "r 12 GA SM INSERT 3°=1'-0" ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 1360 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/- TYP. 0 m 3.000" 4.000" 3.000" MAX. DBL 3 SQ. x OD42 ALUM. BEAM W/ 14 GA STL INSERT 3"=v -o" ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 G60 ALUMINUM BEAM . .& CONTINUOUS STEEL INSERT PER B14/- TYP. 0 0 3.000" 4.000" 3.000" MAX. DBL 3 SQ. x 0-042 ALUM. BEAM " . W/ 12 GA STL INSERT 3"=1'-0° 3 x 8.x 0-042' ALUM. ALLOY 3004-436 ALUM. ALLOY 3004-H36 0.042° TYP. 0 • m 3.000" 4.000° 3.000" MAX 612 DBL 3.x820.042' 0 a m ALUM. ALLOY 3004-H36 STEEL ASTM A653 -SS GRADE 50 G60 - 14 GA CONTINUOUS STEEL INSERT 0.042° N ' N O 2.824" 3.000' 3' SQ,,x 0-032• ALU t BEAM W/- oi3 k STL INSERT 3"=1'-0" ALUM. ALLOY 3004-H36 2.908" 0�, 208 N O cow', o N � 3.000' x �3'Q.32• ALUM BEAM W/V CHANNEL ALUM. ALLOY 3004 0.042" TYP._ 2.000" 4.000" 2.000" MAX B9 DBL 2 x 8 x (1042" i ALUM. ALLOY 3004-H35 I 0.032" o0 TYP. 2.000" 4.000° 2.0�" MAX. 1310 DBL2x8x0.032• FAX 949.305.1420, AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 161071 DATE oaosm DRAWN BY RER CHECKED MDS IAPM0195' V 2.0 LATTICE STRUCTURES: BEAM PROFILES L4.1 C5 1n co n - 14 GA CONTINUOUS STEEL INSERT 0.042° N ' N O 2.824" 3.000' 3' SQ,,x 0-032• ALU t BEAM W/- oi3 k STL INSERT 3"=1'-0" ALUM. ALLOY 3004-H36 2.908" 0�, 208 N O cow', o N � 3.000' x �3'Q.32• ALUM BEAM W/V CHANNEL ALUM. ALLOY 3004 0.042" TYP._ 2.000" 4.000" 2.000" MAX B9 DBL 2 x 8 x (1042" i ALUM. ALLOY 3004-H35 I 0.032" o0 TYP. 2.000" 4.000° 2.0�" MAX. 1310 DBL2x8x0.032• FAX 949.305.1420, AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # 161071 DATE oaosm DRAWN BY RER CHECKED MDS IAPM0195' V 2.0 LATTICE STRUCTURES: BEAM PROFILES L4.1 ASTM A500 GRADE B 0.188• 0 0 0 4.000" C10 HSS 4'x 4 x 3%16 3•=1'-0• ASTM A500 GRADE I 0.188" o o 3.000' C7 H 3 X ;i X ;inti 3"=1'-0" JALUM. ALLOY 3004-H36 3" ALUMINUM OR STEEL POST PER PLAN 0 c) 0.042" c 2.000" 3.000" 2.000" NOTE SEE TABLE 1 ON LI.z FOR APPLICATION OF THIS DETAIL SP4 OD4r OIDC PLATES 3"=1'-0" JALUM. ALLOY 3004-H36 0.032" 0 o 3.000" ASTM A500 GRADE 8 ASTM A500 GRADE 8, ALUM. ALLOY 6063-76 IALUM. ALLOY 3004-H36 t _ 0.250" c' r 0.250" 0 0.762" n TYR KC 62 a 1.500" o 0 .048-" rO456" 0 Li,�TYPT' 0' o +R0.1 F .25 o 4S n 4.000" 3.000" r 3.000" 0 3.000° r NOTE: R IS ACCEPTABLE TO,COVER THIS COLUMN SECTION (FULL HEIGHT) BY R IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHE71CAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. HSS 3 x 3 x 5/16 C8 HSS 3 x 3 x 1/4 3' MAG POST C2 3" SQ ALUM POST v ASTM A500 GRADE B STEL A653 GRADE 50 CP60 ALUM. ALLOY 3004 H36 3" ALUMINUM OR STEEL POST PER PLAN - N � 1.500" 0 0.313" o C! T 0 0.048" o f o �:-45Li o PRO.125 3.000" a 0.032" t r 2.000" 3.000" 2.000' IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED.: SLEEVE SHALL EXTEND FROM THE FOUNDATION, TO THE UNDERSIDE OF SEE TABLE 1 ON L1x FOR APPLICATION OF THIS DETAIL THE BEAM/COLUMN CONNECTION. h C9 HSS 3 x 3 x 5/16 „Q 3' SQ STEEL POST SP3 OA32' SIDE PLATES rt'l Ig I la 2485 RAILROAD ST, pa I tot, CORONA, CA 92880 951.736.4500 �fESS 1 w S 5885 er `JI U`' .,��P iF OF CAI -\E DATE SIGNED: Apn15, 2017 k7VG/R1EE-R//V9 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4STEL JOB# 161071 DATE 04M17 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: COLUMN PROFILES L4.2 I' DURALUM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 CE s 885 OF DATE SIGNED: Apdl 5, 2017 ;Lkjwv 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949:305.1150 1 FAX 949.305.1420 AHJ APPROVAL RIEVISIONS MARK DATE DESCRIPTION 4 STEL JOB 9 16-1071 DATE WW17 DRAWN BY RER IAPMO 195 'V 2.0 LATTICE STRUCTURES: CONNECTORS -L4.3 0.050, lb Ll BRACKET IS 2V LONG LENGTH 2)�' @ SINGLE 3 x 8 OR 3 x BEAM BELOW LENGTH ='8-Y4" @ DOUBLE 3 x 8 BEAM BELOW "W BRACKEr -2x 6 -1/LP RAFrER'TO BEM LENGTH= @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH= 014' @ DOUBLE 2 x Eh" BEAM BELOW LENGTH = 8"-V @ DOUBLE 3 x 8 BEAM BELOW )3 x 8 RAFTER30 BEAM. DURALUM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 CE s 885 OF DATE SIGNED: Apdl 5, 2017 ;Lkjwv 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949:305.1150 1 FAX 949.305.1420 AHJ APPROVAL RIEVISIONS MARK DATE DESCRIPTION 4 STEL JOB 9 16-1071 DATE WW17 DRAWN BY RER IAPMO 195 'V 2.0 LATTICE STRUCTURES: CONNECTORS -L4.3 2 x 6 or 2 x 8 LEDGER - FASTENERS, SEE TABLE 3 SOLID PATIO COVER OR 3 x ALUM. RAFTER — (E) TRUSS OR NOTE WHERE COVER CONSTRUCTION INCLUDES DETAIL A ORB, SITE-SPECIFIC ENGINEERING IS REQUIRED TO VERIFY ADEQUACY OF THE EXISTING STUD WALL FRAMING (INCLUDING HEADER SIZE) WHERE ONE OR MORE OF THE FOLLOWING CONDITIONS OCCUR: LB x 8 x 3/4 x 1" LONG BRACKET - FOR LUSL = 20PSF MAX COVER PROJECTION> 18' AND OPENING IN WALL WIDER THAN 8' AT EA (E) 2 x RAFTER, WITH (3) - FOR SL = 50 PSF MAX COVER PROJECTION > WAND OPENING IN WALL WIDER THAN 6' #14 x 3 r WOOD SCREWS, EA LEG 1/2' MIN (E) BLOCKING BETWEEN CONT. RAFTERS OR TRUSSES RAFTERS @ 24" OC (E) WALL ALLOWABLE PROJ. TO BEAM (E) EAVE OH (E) RAFTER OR TRUSS BACKSPAN Sfifi TeRfiL 1 24' PDX 6'••0" A!IN 4Q'-0" MAK 11.. EXISTING ROOF DESIGN LOADS: RDL = 3 PSF (MIN) TO 8 PSF (MAX) 2. NEW PATIO DESIGN LOADS: LL = 10 PSF MAX (NO SNOW LOAD) 3. PLACE "SIKH FLEX' OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. THE BRACKET MAY ALSO BE MOUNTED BELOW THE RAFTER AS SHOWN. _ALTERNATE EAVE CONNECTION w— — nMLL HANGER w/ FASTENERS PER TABLES 3 & 4 (E) 1" THICK MAX LATH AND PLASTER OR WOOD SIDING z t �M 2 x WOOD STUD WALL SIM AT CONCRETE; BRICK OR MASONRY WALL z 2.5" MIN. NOTE: WALL LEDGER SHALL BE - NOMINAL LUMBER SIZE 2 x 6 (AT 2 x 6h MINIMUM RAFTERS), - NOMINAL LUMBER SIZE 2 x 8 (AT 3 x 8 MINIMUM RAFTERS), OR - KILN -DRY WOOD -FILLED 2 x 6)' OR 3 x 8 ALUMINUM SECTION. WALL CONNECTION O TABLE 2 - NUMBER OF SIMPSON A34s REQUIRED AT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG TABLE 1 - MAXIMUM PROJECTION ASSUMING (E) JOIST SPACING = 24"OC MAX 50 PSF SL LUSL EASTING FRAMING MEMBER AT ROOF OVERHANG 24" OVERHANG LENGTH 18" 17 6" 2 2x4 FULL 1710" 19`11' 24'D" 24' 0' 10 2x6 NOTCHED 20.6" 24' 0" 24' D" 24' 0" 2x6 FULL OR 2x8 NOTCHED 24' 0' 24' 0' 24' Cr 24'0' 2x8 FULL OR 2x10 NOTCHED 24'(r 24' 0' 24'D* 24' Cr 2x4 FULL r9" 11' 10" 19' S 24' 0' 20 2x6 NOTCHED 1Z 3- 1T 10' 24' 0' 24-0- 2x6 FULL OR 2x8 NOTCHED 197- 24' D- 24' Cr 24' 0- 2x8 FULL OR 2x10 NOTCHED 24' 0' 24' 0' 24' 0' 24' 0' 25 2x4 FULL T 4" 11' 3' 18' 7- 24'(r 2x6 NOTCHED 11' 8" 1T 0' 24'0' 24' 0' 2x6 FULL OR 2xB NOTCHED 18' 8' 24' D" 24'(r 24' 0' 2x8 FULL OR 2x10 NOTCHED 24 0' 24' 0' 24'0* 24' 0" 2x4 FULL 5' 11' 9`4" 15 8' 24'(r 30 2x6 NOTCHED 916, 14'2' 2711' 24'(r 2x6 FULL OR 2x8 NOTCHED 165- 2Z 0- 24' 0' 24' D' 2x8 FULL OR 2x10 NOTCHED 24' 0' 24-0- 24'0-. 24' 0' 2x4 FULL 4' 0' 69" 17 0' 24(r 40 2x6 NOTCHED 69, 10' 5" 1T 6" 24'0' 2x6 FULL OR 2x8 NOTCHED 11'4' 16'6" 24' 0' 24' Cr 2x8 FULL OR 2x10 NOTCHED 19'r 24' 0" 24' 0' 24' 0' 50 2x4 FULL 710' 5' 2" 9' 8' 20' 4- 2x6 NOTCHED 61* 8'2" 14'2" 24'(r 2x6 FULL OR 2x8 NOTCHED 1 B-9- IT D- 21'6" 24' 0' 2x8 FULL OR 2x10 NOTCHED 1 15' 6' 21-11- 24-0- 24' 0 - NOTCH CAN BE UP TO 1" IN 2x6, UP TO 1.5" IN 2x8 OR 2x10. MAX (E) ROOF RAFTERS BACKSPAN IS ASSUMED TO BE 40 FT. w— — nMLL HANGER w/ FASTENERS PER TABLES 3 & 4 (E) 1" THICK MAX LATH AND PLASTER OR WOOD SIDING z t �M 2 x WOOD STUD WALL SIM AT CONCRETE; BRICK OR MASONRY WALL z 2.5" MIN. NOTE: WALL LEDGER SHALL BE - NOMINAL LUMBER SIZE 2 x 6 (AT 2 x 6h MINIMUM RAFTERS), - NOMINAL LUMBER SIZE 2 x 8 (AT 3 x 8 MINIMUM RAFTERS), OR - KILN -DRY WOOD -FILLED 2 x 6)' OR 3 x 8 ALUMINUM SECTION. WALL CONNECTION O TABLE 2 - NUMBER OF SIMPSON A34s REQUIRED AT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG TRIB 10 PSF 20 PSF 25 PSF 30 PSF 40 PSF WIDTH LUSL LUSL SL SL SL 50 PSF SL T 1 1 1 1 1 2 8' 1 1 1 1 2 2 9' 1 1 1 1 1 1 2 1 2 10' 1 1 1 2 2 2 11' 1 1 2 2 2 2 1Z 1 1 2 2 2 1 2 USE (8) SIMPSON SD9112 SCREWS INTO EACH A34 WHEN USING (2) A34s, PROVIDE 2x FULL DEPTH WOOD SCAB, FULL LENGTH OF RAFTER TAIL TABLE 3 - FASTENERS REQUIRED AT LEDGER AND ROOF PANEL RAILTO FASCIA OR LEDGER TO EXISTING WOOD STUD WALL FRAMING TRIS 10 PSF 20 PSF 25 PSF 30 PSF 40 PSF 50 PSF WIDTH LUSL LUSL SL SL SL SL S A A A A A A 6' A A A A A A T A A A A A A 8' A A A A A A 9' A A A A A B 10' A A A A A C 11' A A A A B C 17 A A A A B C A (2) 114" LAG SCREWS B (2) 5116• LAG SCREWS C ,(2) 7/16- LAG SCREWS NOTES: 1 - ANCHORS ARE TO BE SPACED AT 16" O.C. HORIZONTALLY IN DIRECTION PARALLEL TO WALL 2 - WHERE ROOF PANEL RAIL OCCURS, USE 1/Z DIAMETER LAG SCREW OJ LIEU OF (2)11V DIAMETER LAG SCREWS. ' r SIMPSON A34 SEE TABLE 2 --- FASTENERS, SEE TABLE 3 (E) BLOCKING I BETWEEN CONT. RAFTERS OR TRUSSES SOLID PATIO COVEROR 3 x ALUM. RAFTER 2 x FULL DEPTH WOOD (E) TRUSS OR SCAB, WHERE OCCURS,t�f RAFTERS @ 24" OC EXISTING FASCIA BOARD SEE TABLE 2 ALLOWABLE PROJ. TO BEAM SAVE OH E. RAFTER OR TRUSS BACKSF SFE TABLE 1 24" MAX 6'-0` MIN 40'-0" MAX NOTE: EXISTING ROOF DESIGN LOADS: ROL = 3 PSF (MIN) TO 8 PSF(MAX) RLL = 20, 25, 30, 40 OR 50 PSF EAVE CONNECTION TABLE 4 - ANCHORS INSTALLED INTO THE SIDE OF 6 IN THICK MIN CONCRETE OR CMU WALLS IN CONCRETE, USE 1/2" DIA SIMPSON STRONG -BOLT 2, STAINLESS STEEL, WITH 3" MIN EMBED, INSTALLED PER ICC -ESR -3037. IN CMU, USE 1/2" DIA SIMPSON WEDGE -ALL, STAINLESS STEEL, WITH 3 318" MIN EMBED, INSTALLED PER ICC -ESR -1396. MAXIMUM ANCHOR SPAGNG 10, 20, 25 PSF 30 PSF 40 PSF 50 PSF WSL SL SL SL 48" 36" 36" 24" USE 3' SO -x1/4" STAINLESS STEEL WASHER WHEN INSTALLING NEW WOOD LEDGER AGAINST EXISTING CONCRETE WALL J- DURALUM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS►gy4 S5885 OF CAS DATE SIGNED: April 5, 2017 E/�AG!/�'EE"Fv?lf�erG 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 AHJ APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 161071 DATE 005117 DRAWNBY RER CHECKED MDS IAPM0 195 V 2.0 LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L6..1 W -WI 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS Ico gyq� w S 5885Er m P TglF OF CpI.,E��\ DATE SIGNED: April 5, 2017 ;UAN ll�IEE/t`�i 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 ( FAX 94 9.305.1420 ' AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB /E 161071 DATE 04105117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.2 (E) BLDG 3" x.8" x 0.042" HEADER (E) STUD WALL jV �I (3 cc SCREW TYP. v o 14 SMS �I DECK/RAFTER ii EA- SIDE DIRECTION TRIBUTARY II -- ---- -+- —t� AREA • - 2" COLUMN MIN. BEAM (E) BLDG (E) 1" THICK MAX LATH AND L L ,/ PLASTER OR WOOD SIDING 3" x 8" RAFTER BRACKET BEAM I \\�\\ j \ %. NOTES: COLUMN j TRIBUTARY 1, USE OF THIS DETAIL IS LIMITED TO THE FOLLOWING: $ $ AREA FOR LL/SL = 10 PSF, MAX TRIB AREA TO CONNECTION = 100 FT2 i FOR U_/SL = 20 OR 25 PSF, MAX TRIB AREA TO CONNECTION = 55 FT2 / FOR SL = 30 PSF, MAX TRIB AREA TO CONNECTION = 45 FT2 E0. E0. DECK/RAFTER FOR SL > 30 PSF, DETAIL IS NOT ALLOWED DIRECTION 2. SEE PLAN FOR DEFINITION OF TRIBUTARY AREA PLAN 3. BEAM MUST UNE UP WITH EXISTING WALL STUD. BEAM'EIRACKET N.T.S. EXISTING STUD ALUMINUM MEMBER WITH FILL OR 2X NOMINAL WALL WITH*LATH SHEATHING AND (NEW OR EXISTING) STUCCOTAIL B/L6.1 \ - (3) Y40 x 2" FULL - LENGTH THREADED ' LAG SCREWS LEDGER TO WALLFASTENERS PER.RAFTER PER PLAN BL6.1(E) PER 3/L6.2, i''THICK MPS PLASTER OR W - U'BRACKET, SIM TO 2/L4.3 OR 3/L4.3 NOTES: _ 1. MAX SPANOF SINGLE RAFTER SHALL BE AS FOLLOWS: 10 PSF - 24' FOR 24" SPACING, 36' FOR 16° SPACING 20 PSF - 12' FOR 24" SPACING, 18' FOR '16° SPACING 30 PSF -,8' FOR 24" SPACING, 12' FOR 16" SPACING 2. SEETHIS DETAIL SHALL NOT BE USED FOR SNOW LOADS HIGHER THAN 30 PSF 1 2 RAFTER TO LEDGER CONNECTION - 1" THICK MAX LATH AND PLASTER OR WOOD SIDING ^ RAFTER PER "PLAN C5 :0 FOR U./SL = 10 PSF, - I USE (2)#14 SMS EA SIDE AND (3) Y"O x 3T LAG SCREWS. _. FOR LL/SL = 20, 25, OR 30 PSF, Z" USE - (3)014 SMS EA SIDE AND (3) WO x 314" LAG SCREWS. - u FOR SL = 40 OR 50 PSF, .r - r.._ _ - _ 'USE (4)#14 SMS FA SIDE :y.` t. _ ^' . .r _ ... AND (3) VO x 3X1" LAG SCREWS. (E) SND WALL NOTE USE LEDGER PER 2/L6.2 WHERE RAFTER SPACING EXCEEDS EXISTING SND SPACING, SEE TABLE 3 SHEET 1.6.1 RAFTER TO STUD WALL 3 CONNECTION W -WI 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS Ico gyq� w S 5885Er m P TglF OF CpI.,E��\ DATE SIGNED: April 5, 2017 ;UAN ll�IEE/t`�i 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 ( FAX 94 9.305.1420 ' AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB /E 161071 DATE 04105117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.2 EKvr- DU -ALUM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �pEESS I(y� w o S5885 m o: T Lr.T1� !�F OF CA \L E DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB S 161071 DATE _ 04105117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.3 #8 SMS LATTICE ATTACHMENT PER 7/1-63 l 3 x 8 x 0.42 BEAM OR 3" SQ. STEEL BEAM OR MAG BEAM DOUBLE BEAM J (4) 014 SMS EA 89, 810, B12, (. (6)-$14 SDS @ EA SIDE RAFTER TO COLUMN 815 OR 816 (6 �) TOP &BOT TOTAL = 24 1V SO. OR 2' SO. OR 2 x 3" LATTICE @ 3" O.C. 5/8'0 HOLE WITH MIN_ UP TO 6" O.C. MAX. o I O PLASTIC PLUG, AS H BRACKET PER 1 S4.3 / I REQ'D, TYP. IT IS OR 1/LS.3 ACCEPTABLE TO USE RAFTER I o I ONE HOLE TO 3' OR 4" SQ. I INSTALL SEVERAL ALUM. OR STEEL POST o I SCREWS. EYP. w I , 3 x 3 x .024 (3) #14 SMS CONNECTOR EACH SIDE LATTICE TUBE T4 RAF?FR ST11R mi LIMN To ORI. R,FAMCI TO POST 4 CONNECTION 1-1 2'=1' 0" t....__; O LATTICE ATTACHMENT PER 7/1-6.3 SPLICE WHERE OCCURES 1/2' MAX SPLICE (INT COL ONLY) WHERE OCCURS (INT COL ONLY) (6) #14 SMS @ EACH HEADER TO COLUMN 1/2- TYP DBL RAFTER (12 FASTENERS PER DOUBLE BEAM B9, CONNECTION) B10, 812, B15 OR (4) X14 SMS EA RAFTER 816 TO COLUMN (8 TOTAL) 5/8"0 HOLE WITH II 5/8"0 HOLE WITH PLASTIC PLASTIC_ PLUG, AS I II ' PLUG, AS REQ'D, TVP. R IS REO'D, TVP. R IS ACCEPTABLE TO USE ONE ACCEPTABLE TO I�® ® I HOLE TO INSTALL SEVERAL USE ONE HOLE SCREWS, TYP. TO INSTALL I SEVERAL SCREWS, I II I i I TYP. I II ATTACHMENTS PER 2/1-6.3 ® I I "' (2)#14 SMS EACH I I DBL BEAM B9, 810, 812, SIDE T&B @32' I I ARCHITECTURAL SIDE B15 OR 816 O.C. I PLATES, WHERE OCCUR, SHALL STOP & FLUSH I I I ' I 3' OR 4" SQ. POST W/ BELOW BEAM OPTIONAL SIDE PLATE OR ARCH COL WHERE OCCURS 3" OR 4" SQ. POST DBL RAFTER TO DBL BEAM�2� DBL BEAM TO COL �- .1 CONNECTION ' r 3" WIDE BEAM TYP B2." MAX. B5, B11, B13 OR 614 3" OR 8" BEAM (6)'#14 SMS EA SIDE AT SPLICE SMS PER ELEVATION, TYP. AT SIDE PLATE SP3 B Vo PLASTIC PLUG, TVP.' (8) SMS EA SIDE o AT SIDE PLATE SP4. I SEE NOTE 1. „ e • n W PROVIDE FULL BEARING OF e e o BEAM ON POST. R W ne %'0 HOLE WITH PLASTIC PLUG, AS i o' i n ,e e, o o REQb, TYP. R IS ACCEPTABLE TO a e' o a � " SIDE PLATE EA SIDE USE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP. (2) #14 SMS EA SIDE AT 0T SIDE PLATE EA SIDE, SEE 3' SQ. POST BETWEEN BOTTOM AND AT 32" OC MAX. TABLE 1 ON S1.x OR"L1.x SIDE PLATES OPTIONAL STYROFOAM INFILL OF ELEVATION SIDE PLATES CAN STOP BELOW (." SECTION 3" SQ. POST BETWEEN SIDE PLATES THE CONNECION BEAM TO POST CONNECTION .7 eI0 K M 10®1 / .HaG1t SIL 6 BMI EKvr- DU -ALUM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �pEESS I(y� w o S5885 m o: T Lr.T1� !�F OF CA \L E DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB S 161071 DATE _ 04105117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.3 STEEL SLEEVE PER 4/1_7-2 AT POST, TYPE C7, C8, k C9 BOLTS PER TABLE 2 ADJACENT NT 3' OR 4' STEEL POST. ! I ADJACE GRADE iYP. GRADE TYP. I� —I— i I i I - •4 - U a < z ? 3'MIN. u4/L;2 a a ° li J PER 4/1.7.2 zw+ TYP. , w v o NO A36 o o F-- • THREADED ROD a a w oto w w N� 9 • 4 ° • ci � 4' x, ci �m - �m � r . POURED " „I I. • =1 I II''` POURED CONCRETE CONCRETE I' WIDTH =LENGTH (IN) L WIDTH•= LENGTH (IN) ' SEE FTG. SCHEDULE SEE FTG. SCHEDULE IN BEAM SPAN TABLES IN BEAM SPAN TABLES NOTES. NOTES, 1. THIS DETAIL CAN BE.USED FOR STEEL POST TYPES C6, C7, C8, OR C9. 1. THIS DETAIL IS TO BE USED FOR POST TYPES CIO k C11. 2. THIS DETAIL SHALL NOT BE USED FOR STEEL POST TYPES C1, C2, OR C5. 2. THIS DETAIL CAN ALSO BE USED FOR STEEL POST TYPES C6, C7, C8, C9. 3. R IS ACCEPTABLE TO EJdBED THE STEEL POST DIRECTLY INTO THE FOOTING 3. THIS DETAIL SHALL NOT BE USED. FOR ALUMINUM POST TYPES C1, C2. PER 5/0.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL OR C5. STEEL POST SLEEVE CONNECTIONSTEEL POST EMBEDDED TO CONCRETE FOOTING '1•=1'-o" E. INTO CONCRETE FOOTING 11 TABLE 3 - (MAX WIND SPEED: 130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE 7 BRACKET PER 1/L7.2, ROLLED FORMED PANS (RF) IRP TRI WIDTH U/SL(psf) SL(psf) 10 psf 20 psf 25 psf 30 psf LL/SL(psf) 10 psf 20 psf 5' 11'-9" 11'-0" 10'-4" 9'-0" 12'-6" 10'-0" 6' 10'-9" 9'-9" 9'-0" 8'-4„ 10'-S" 8'-9" 7' 10'-0" 9'-0" 8'-0" T-6" 9'-0" 8'-0" 8' 9'-4" 8'-6" 7'-6" T -O" T-10" 7'-6" 9' 8'-10" 8'-0" 7'-0" NP 7'-0" 7'-0" 10' 8'-6" 7'-6" N.P. NP 6'-3" 6' -6 - ill 8'-1" 7'-0' NP NP 51$" 6'-0" 12' 7'-8" 6'-6" NP NP 5'-3" 5'-6" NOTES: 1 -"NP INDICATES THATA FOOTING IS REQUIRED,ANDTHE PATIO COVER CAN NOT BE SUPPORTED ON A SLAB ON GRADE. 2 -FOR UVE OR SNOW LOADS HIGHER THAN THE ONES SHOWN ON THIS TABLE, A FOOTING IS REQUIRED AND THE PAT10 COVER CANNOT BE INSTALLED ON SLAB ON GRADE. (� T BRACKET CONNECTION TO SLAB ON GRADE. 3" STEEL OR ALUMINUM POST ADJACENT GRADE 7 BRACKET PER 1/L7.2, WHERE OCCURS 2/02 OR 3/L7.2 BRACKET EXISTING OR NEW SLAB ON MIN. :i �i GRADE fc=2,500 PSI MIN. Altl WxLxD (SEE NOTE 2) AIt2 WxLxD (SEE NOTE 3) Alt 3 (ATTACHED) WxLx18" (SEE NOTE 4) c z �H • � AIt7 WxLx36' (SEE NOTE 8) AItB WxLx42' (SEE NOTE 9) GE OF SLAB BOLTS PER TABLE 2 WHERE OCCURS 18 x18x 38 NOTES: 1 -"FTG (IN)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS SSxxx OR LSxxx. 2 -"ALT 1' IS THE FOOTING DIMENSION BASED ON THE'FTG(IN)- DIMENSION. NOTETHATW=D=L F.. 3 -ALT 2' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A 35' MIN THICK SLAB 15 PRESENT ABOVE THE FOOTI NG. NOTE THAT Wed. 4 - "ALT3' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 18" DEPTH FOR UPLIFT DESIGN ONLY. THIS VALUE IS TO BE USED ONLY AT ATTACHED PATIO STRUCTURES. NOTE THAT Wd AND D=18'. S -"ALT 4' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18" DEPTH. NOTE THAT Wd AND D=18-. 6 -'ALT 5' IS THE ALTERNATE FOOTI NG DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 24' DEPTH. NOTE THAT W d AND D=24". 7 - "ALT6' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT MAN 30' DEPTH. NOTE THAT Wd AND D=30-. 8 -ALT 7' IS THE ALTERNATE FOOTI NG DIMENSION REQUIRED WHEN THE FOOTI NG IS KEPT TO AN 36' DEPTH. NOTE THAT Wd AND D=36-. 9 -'ALT S" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 42" DEPTH. NOTE THAT WdAND D-42-. (� FOUNDATION TABLES TABLE 2 - ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) TABLE 1 ALTERNATE FOOTING DIMENSIONS BRACKET DETAIL POSTTYPE FrG(IN) ANCHOR BOLTS (SEE NOTE 2) FIG (IN) W=L=D (SEF NOTE 1) Altl WxLxD (SEE NOTE 2) AIt2 WxLxD (SEE NOTE 3) Alt 3 (ATTACHED) WxLx18" (SEE NOTE 4) AIt4 WxLx18' (SEE NOTE 5) AIt5 Wxlx24" (SEE NOTE 6) AIt6 WxLx30" (SEE NOTE 7) AIt7 WxLx36' (SEE NOTE 8) AItB WxLx42' (SEE NOTE 9) 18 18x 18x 18 12 x12x 12 18 x18x 38 18 x18x 18 16xl6x24 14x 14x30 13x13x 35 12x12x42 20 20 x20x 20 12x12x12 21 x21x 18 25xISx18 19 x19x24 17xl7x30 15 x15x36 14 x14x42 22 22x22x22 16x16x16 2Sx25x18 33x33x18 21 x21 x24 19x19x30 17x17x36 16x16242 24'' 24x24x24 20 x20x20 28x28xl8 43x43x18 24 x24 x24 22x22x30 20 x20x 36 18x IS 42 26 26x26x26 23x23x23 32x32x18 STEELT 31x31x24 24x24x30 22x22x36 21x21x42 28, 28 x28x 28 25x2Sx2S 35x35x18 (4)-1/2' dia w/ 3-1/4' embed 38x38x24 27x 27x30 25 x25x 36 23 x23 x42 30 30x3Ox3O 28x28x28 39x39x18 2 35' (0-3/4' dia w/ 4-3/4" embed 30x 30x 30 28 x28x36 26x26x42 32 32x32x32 .30x30x30 43x43x1S 37x37x30 30x30x36 28x28x42 34 34x34x34 32x32x32 47x47x18 33x33x36 31x31x42 36 36x36x36 34x34x34 51 xS1x18 36 x36x 36 34 x34 x42 38 39 x38x 39 37x37x37 5SxSSx1S 43 x43x36 36x36x42 40.. .40 x40x 40 39x39x39 60x60x18 39 x39x42 42 42 x42x42 41 x41 x41 64x64x 18 42x42 x42 NOTES: 1 -"FTG (IN)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS SSxxx OR LSxxx. 2 -"ALT 1' IS THE FOOTING DIMENSION BASED ON THE'FTG(IN)- DIMENSION. NOTETHATW=D=L F.. 3 -ALT 2' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A 35' MIN THICK SLAB 15 PRESENT ABOVE THE FOOTI NG. NOTE THAT Wed. 4 - "ALT3' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 18" DEPTH FOR UPLIFT DESIGN ONLY. THIS VALUE IS TO BE USED ONLY AT ATTACHED PATIO STRUCTURES. NOTE THAT Wd AND D=18'. S -"ALT 4' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 18" DEPTH. NOTE THAT Wd AND D=18-. 6 -'ALT 5' IS THE ALTERNATE FOOTI NG DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 24' DEPTH. NOTE THAT W d AND D=24". 7 - "ALT6' IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT MAN 30' DEPTH. NOTE THAT Wd AND D=30-. 8 -ALT 7' IS THE ALTERNATE FOOTI NG DIMENSION REQUIRED WHEN THE FOOTI NG IS KEPT TO AN 36' DEPTH. NOTE THAT Wd AND D=36-. 9 -'ALT S" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPT TO AN 42" DEPTH. NOTE THAT WdAND D-42-. (� FOUNDATION TABLES NOTES: EMBED 5/V.1 C10,C11 ALL 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C3, C5 OR C6. NOTES: 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES 1 -'FTG (IN)" 15 THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON AND/OR COMMERCIAL APPLICATIONS. SHEETS U3xxx 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CIO, 2 -ANCHOR BOLTS SHALL BE SIMPSON STRONG BOLT2, STAINLESS STEEL (ICC -ESR C11. 3037) 4. SLAB ON GRADE SHALL BE IN GOOD CONDITION (NO VISIBLE CRACKS 3-ITISACCEPTABLETOUSE THE STEEL INSERT PER 4/VIINSTEADOFTHE WITHIN 33" FROM POST). AWMINUM T PER 2/L72 FOR POSTTYPES C2 AND C5. BOLTS CAN CAN REMAIN AS 5. MINIMUM OVERALL DIMENSION OF SLAB ON GRADE SHALL BE PER SPECIFIED INTHISTABLE. FOOTING NOTE 4 ON GOA 4-ITISACCEPTABLETOUSE THE EMBEDDED POST DETAILSA7.11NSTEADOFTHE _ STEEL INSERT OR STEELT FOR STEEL POSTS C6. 5- IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL 5/v1 I NSTEAD OF THE STEEL INSERT FOR STEEL POSTS C7, CS AND C9. (4'�YAMNCHOFMMGE OF POSTS O SLABOR FOOTING i BRACKET PER 1/L7.2, 2/L7.2, 3' STEEL OR OR 3/1.7.2. ALUMINUM POST I r—BOLTS PER TABLE 2 ADJACENT GRADE TYP. III—I i � e a �•• ; � �-� I I'-1 i o w . ir W w < e POURED CONCRETE FOOTING W ANN Ga o • , w cF'i N ILm 4 ` WIDTH =LENGTH QN 'SEE FTG. SCHEDULE I BEAM SPAN TABLE NOTES: 1. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 2. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8„ C9, CIO. CI 1. / l T BRACKET CONNECTION ,.= TO CONCRETE FOOTING 1+=1'-0"' ,c i 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�EESS I co S.58 5 ry UCT� TF OF CALLF� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16.1071 DATE NOW17 DRAWN BY RER CHECKED MDS IAPM0195� V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS L7.1 TABLE 2 - ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) BRACKET DETAIL POSTTYPE FrG(IN) ANCHOR BOLTS (SEE NOTE 2) SEE NOTES ALUM T 1/0.2 C1 SOG (2)-3/8' dia w/ 1-7/8' embed ALUM 1/V2 C1 ALL (2)-3/8'dia w/2-7/8'embed ALUM 2/1.7.2 C2 SOG (2)-3/8' dia w/ 1-7/8' embed 3 ALUM T 2/1.7.2 C2 I ALL (2)-3/8' dia w/ 2-7/8' embed 3 ALUM T 2/02 CS SOG (2)-3/8' dia w/ 1-7/8" embed 3 ALUM T 2/V 2 CS ALL (2)-3/13' d)a w/.2-7/8' embed 3 STEELT 3/01 C6 SOG W-3/8" dia w/ 1-7/8" embed STEELT 3/1.7.2 C6 522' (2)-3/8'diaw/2-7/8'embed 1,4 STEELT 3/1.71 C6 524" (2)-1/2' di a w/ 3-1/4' embed 1,4 STEEL INS 4/L7.2 C6 5 30" (4)-1/2' dia w/ 3-1/4' embed 1,4 STEELINS 4/V2 6 C34' 5 (4)-5/8'diaw/4"embed 1,4 STEEL INS 4/02 C6 2 35' (0-3/4' dia w/ 4-3/4" embed 1,4 STEEL INS 4/02 C7, C8, C9 ALL (4)-3/4' dia w/ 4-3/4' embed 1,5 N/A NOTES: EMBED 5/V.1 C10,C11 ALL 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C3, C5 OR C6. NOTES: 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES 1 -'FTG (IN)" 15 THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON AND/OR COMMERCIAL APPLICATIONS. SHEETS U3xxx 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CIO, 2 -ANCHOR BOLTS SHALL BE SIMPSON STRONG BOLT2, STAINLESS STEEL (ICC -ESR C11. 3037) 4. SLAB ON GRADE SHALL BE IN GOOD CONDITION (NO VISIBLE CRACKS 3-ITISACCEPTABLETOUSE THE STEEL INSERT PER 4/VIINSTEADOFTHE WITHIN 33" FROM POST). AWMINUM T PER 2/L72 FOR POSTTYPES C2 AND C5. BOLTS CAN CAN REMAIN AS 5. MINIMUM OVERALL DIMENSION OF SLAB ON GRADE SHALL BE PER SPECIFIED INTHISTABLE. FOOTING NOTE 4 ON GOA 4-ITISACCEPTABLETOUSE THE EMBEDDED POST DETAILSA7.11NSTEADOFTHE _ STEEL INSERT OR STEELT FOR STEEL POSTS C6. 5- IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL 5/v1 I NSTEAD OF THE STEEL INSERT FOR STEEL POSTS C7, CS AND C9. (4'�YAMNCHOFMMGE OF POSTS O SLABOR FOOTING i BRACKET PER 1/L7.2, 2/L7.2, 3' STEEL OR OR 3/1.7.2. ALUMINUM POST I r—BOLTS PER TABLE 2 ADJACENT GRADE TYP. III—I i � e a �•• ; � �-� I I'-1 i o w . ir W w < e POURED CONCRETE FOOTING W ANN Ga o • , w cF'i N ILm 4 ` WIDTH =LENGTH QN 'SEE FTG. SCHEDULE I BEAM SPAN TABLE NOTES: 1. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 2. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8„ C9, CIO. CI 1. / l T BRACKET CONNECTION ,.= TO CONCRETE FOOTING 1+=1'-0"' ,c i 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Q�EESS I co S.58 5 ry UCT� TF OF CALLF� DATE SIGNED: April 5, 2017 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 FAX 949.305.1420 AHJAPPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R 16.1071 DATE NOW17 DRAWN BY RER CHECKED MDS IAPM0195� V 2.0 LATTICE STRUCTURES: FOUNDATION DETAILS L7.1 • ma"""y.:, • .,. 2485 RAILROAD ST, ' CORONA, CA 92880 951.736.4500 Q�FEssrcy�� Lutr � S 5885 frF OF �0\ DATE SIGNED: April 5, 2017 Or A'Ava. 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 AHI APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB W 16-1071 DATE D41D5117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0. LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 120 MPH L8. 10.2 ATTACHED & FREESTANDING -LATTICE COVERS'40 PSF SNOW LOAD OR LIVE LOAD -120 MPH = EXP. B & C. 63 a . 3" SQ. ALUM W/3 12 GA ST."U"CHANNEL B9 DBL 2x6.5x0.042 611 3x8x0.042 g1p DBL 2 x 6.5 x 0.032 612 DBL 3x8x0.042 613 x8 x 0.042 W/ r " 14 GASTL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIG WIND MAX POST FTG. MIN. POST MAX POST FTG . MIN.' POST MAX POST FTG. MIN. POST MAX. POST FTG. MIN. POST MAX, POST FTG. MIN. POST MAX POST FTG. MIN. POST MAX POST MIN. FTG. MAX POST MIN. FTG. POST MAX POST FTG. MIN. MAX MIN. POST FTG. MAX POST MIN. FTG. MAX POST MIN. FTG. WIDTH EXP. SPACING (IN.) TYPE SPACING ' (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING POST (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) POST TYPE SPACING (IK) TYPE POST SPACING (IN.) TYPE POST SPACING (IN.) POST TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) ' 5 120 B • 15-9" 16 Cl 14'-T 31 C8 14'-10" 15 Ct 14'-10" . 30 C7 154" 15 Cl 15'x' 30 18'-0" 16 18'-0" 31 C7 21'4r 17 21*4r 33 20-9 17 20 9" 32 C7 14'-T 33 610 14' 6" 18 14'-1" 31 r' 17-0" 31 C8 21'-4" 20 120 C 16'-V 18 , 15-T 18 14'-7" 31 C7 C1 1T-8" 19 ._ Cl C8 20'-7- 3d 2a-4" C1' 20 - 19'x" 34 C8 1 6, 120 B 15'-3" 16 Cl 13'-3" 30 C8 13'-T 16 Cl 13-T 29 14'-1" 16 14'-1" 29 161•4" 17 ICI 16'-4" 30 19, T 18 19-9" 32 C7 19-0" 18 Cl 19-0" 32 C7 120 C 15' 0' 19 C7 ClC7 16'-2" 19 1ST 30 C7 19'-T 21 C2 13-3" 32 C9 13'-4" 18 12'-10" 31 13'-10" 18 1314" -Ti- 18=9" 34 C8 18'-" 20 C2 18'-0" 33 CB T 120 B 14' Z' 17 Cl 12-0" 29 C7 17-T 16 Cl 17-T 29 C7 13'-1" 16 13=1" 29 C7 15'-2' 17 15'-2' 30 - 18'4" 18 18'-4' 31 C7 1T -T' 18 1T-7" 31 ` 12'x" 31 C9 17�" 19 17-0" 30 17-10" 19 12�" 30 120 C 1310" 19 Cl 15'-0" Cl 20 �. 14'-4" 30 C7 18'-1" 21 C2 1T4" 33 C8 1T-3' C2 21 16'x" 33 C7 8 120 B 13-3 17 C1 11'-T' 29 C7 111-T 17 C1 11'-9" 28 C7 17-3" 17 12'-3- 28 14'-3' 18 r Cl 14-3" 29 1T-2' 19 1T-2' 31 16'{ 18 . 16-6" 30 120 C 13'-0 20 11'-T 31 C8 11'x" 19 11'-2' 30 17-1" 19 C1 11'-T 30 14'-1' 20 I, C2 13'-0" 29 C7 _T7-0 22 16'-3" 32 C7 16'T 21 15'-7" 32 C7 9 12081 17-T 18 C2 11'-0" 29 C7 11'-T 17 Cl 11'-2 29 C7 11'-T 17 29 13'-0" 18 13'-0" 30 16'-3" 19 16'-3' 31 15�" 19 15'•8" 31 120 6 17-3 20 11'-0" 30 C8 11'-0 20 10-T' 29 11'-0" 20 C1 -11=T 11-0 29 13'-3 21 12=9" 30 C7 _T'-0" 22 15'-0" 32 C7 15J" 22 14'x" 72- C7 r lff • 120 8 17.0 18 G2 10'-4" 30 C7 10-T 17 Cl 10 T 29 C7 11'-0" 17 111P 29 12'-9" 18 17-9 30 15'4" 19 154" 32 14'-9' 19 14=9" 31 12Di I1'�" 21 Ct C7 1C'7n C2 29. 12'1" ?4 C7 CS C7 1A.7. 41 14 C5 72 C7 10'41" JG GO 10''i," EO IOL+" 19 10L? YO 10'4" 20 +�'•? 11' * 120 B 11'-4" 16 9'-10" 30 10'-1" 17 C1 10'-1" 29 C7 10-0" 17 10S 29 17-T 19 1 12'-2" 31 14'x" 20 14'x" 32 14'-1" 19 14'-1" 32 j 120 C 11'-2" 27 9'-T 29 10-3 20 9'b 29 9A D" 30 10'-0" 20 C1 C7 12'-0 21 'i 11'-T 30 C7 14'6 23 14' 0 32 C7 13'-10" 23 C5 13' 4' 31 C7 " 17;* 120.B 1010" 18 9-0 30 08 9$ 18 9B 29 C7 9S 18 9 8" 29 11'� 19 11' 8 31 14'-t" 20 14-1" 32 C7 13-0 20 13' 8 32 120 C 10 8 21 9£ 31 9'-T 21 C7 11'& 22 11'-1" 31 C7 17-9' 32 C7 9-2 30 9'�' 21 6� 30 13-10 23 13�" 32 C8 13-3 23 CS f� 614 O3 x 8 x0.042 BEAM W/, DEL 3x8x0.042W/ DBL3x8x0.042W/ �+~ 12 GA STL INSERT 615 O DBL 14 GA STL INSERT 616 O DBL 12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN MAX MIN. y TR1B WIND POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST- FTG. POST FTG. ` WIDTH Ems. SPACING ON.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING POST (IN.) POST (IN) a (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) TYPESPACING (SPAN) TYPE 5 120 B 22'x" 18 Cl 72'x" 33 C8 29-Z' 19 29-7' 35 C9 37-0' 20 32•� � 1+ 120 C 22-4" 20 C2 21'x" 35 C9 28'-9" 22 C2 2T4r 37 C11 32'-0" 23 30'-3" 671 38 6 120 B 20'S 18 C2 20'-" 32 C7 26'4" 20 C5. 25-8" 35 C9 29-2" 20 29'-2 35 C9 a 12D C 20'x' 21 19'-8" 34 C8 25-3" 23 25-3' 36 C11 29-T CS 23 2T4" 37 C11 I T 120 B 19'-7 19 C2 19-7' 32 C7 24'f" ' 20 CS 24'-g' 34 C8 2T-1" 21 27'-1'. 35 C9 t ' 120 C 15-10 21 18'-7' 33 C8 24'-4" 23 2T- 36 C9 2T-1" C5 24 25'-8' 37 C11 5 120 B 18'-0" 19 18'-0"' 31 CT 23'-7' 21 C5 23'-Z' 33 C8 25-3" 21 25-7 34 C8 ' 120 C 1T-8" 22 17'-1" 33 C8 27-9' 24 22'-0' 35 C9 26-T C5 25 24'-( 36 C11 NOTES: 9 120 B 1T O 19 CS 1T-0" 32 C7 21-10" 21 CS 21-10" 34 C8 23-10" 22 ' �" ` 23'-1(" 35 WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL 120 C 15 8 22 16'-1" 32 21'E 24 20'$' 34 C9 23-10" . 25 22'-0" 35 F APPUCA71ONS ONLn THE MAXIMUM POST SPACING IS THE LOWEST OF THE 10 120 B 16'-1" 20 C5 15-1" 32 C7 20.9" 21 CS 2(Y 9 34 C8 22'x" 22 CS 22'4' 35 C9' "MAX POST SPACING(SPANr SHOWN ABOVE AND THE MApMUM POST 120 C 15-10" 23 15-3' 32 20 4" _ 25 19 8 34 27 8 26 22'-1" 35 SPACINGS SHOWN ON DETAIL 6IL7.1 11' 120 B 164. 20 C5 15-4" 32 C7 19-9" 22 CS 35 C9 21'-8" 22 21'46' 36 -' I - .- 1 ,r 120 C 15'-T 23 14'-7- 32 C8 194 25 18'19 34 21'S 26 21'-1' � 35 , 17 120 8 14'-9" 20 CS 14.4133 19-0 22 C5 19� 35 C9 20'4" 23 2CS 0'4" 36 611 120 C 14' 8" 23 14.' 0" - 32 18'-0" 26 15-0 34 20'4" 26 20-2 35 C9 r . 41 • ma"""y.:, • .,. 2485 RAILROAD ST, ' CORONA, CA 92880 951.736.4500 Q�FEssrcy�� Lutr � S 5885 frF OF �0\ DATE SIGNED: April 5, 2017 Or A'Ava. 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 AHI APPROVAL REVISIONS MARK DATE DESCRIPTION 4 STEL JOB W 16-1071 DATE D41D5117 DRAWN BY RER CHECKED MDS IAPM0195 V 2.0. LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 120 MPH L8. 10.2 2485 RAILROAD ST, - CORONA, CA 92880 951.736.4500 pFESS ICYyyI W S5885 OC TF OF DATE SIGNED: April 5, 2017 Io ,A TCL_ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 1949.305.1150 1 FAX 949.305.1420 • . AHJAPPROVAL r REVISIONS F DATE DESCRIPTION L JOB # 16.1071, DATE - 005117 DRAWNBY RER CHECKED MDS 'IAPM0_'195` V 2.0 `} LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 130 MPH C, L-8-.110.-3- ATTACHED & FREESTANDING LATTICE COVERS - 10 PSF,SNOW LOAD OR LIVE LOAD-130.MPH - EXP. B:& C- 65 3"SQ. ALUM W/ gy DBL2x6.5x0,042 B11 3 x 8 x0.042 610 DBL 2x6.5x0.032 B12 DBL3x8x0.D42 613 3 x 8 x0.042 W/ 14 GA STL INSERT 12 GA STL"U" CHANNEL " ATTACHED FREESTANDING • - ATTACHED FREESTANDING ATTACHED • -FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING - ATTACHED FREESTANDING _ s " MAX MIN. MAX ^^- MIN. MAX - MIN. MAX - MIN. MAX MIN.MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN, MAX MIN. MAX MIN. TRIG WIND POST FTG. POST POST FTG: POST POST FTG. POST POST FTG. POST POST FTG. POSTPOST FTG. POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST WIDTH EXP. SPACING (IN.) TYPE SPACING (IN.) SPACING (IN.) SPACING OR) SPACING (IN.) TYPE (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE (SPAN) (SPAN) TYPE (SPAN) TYPE (SPAN) SPE (SPAN) ESPACING (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 1308 16-9' - 17 14'-T 33 C9 14'-10 16 14'-10 31 1ST' 16 31 18'0 17 1T-" 33 C7 21'-8" 19 21-0" 34 C8 20'-9" 18 C1 20'4" 32 C8 5 130C 15'-0 19 C114 C113'S 33 C714'-10" 19 Ct33 . C7 1T3 2D C1 C7 19'-1" 34 C9 -T 34 C10 14' 4" 19 16-0" 34 C8 20'-10' 21 20'-0" 36 C11 20� 21 130 8 15-3" 18 13'-3" 31 C9 13'-T 17 13'-T' 31 14'-1" 17 13-10 31 16'-4" 18. 16'-7' 32 C7 19-T 19 19'-T 33 C8 19-0 19 Cl 1", 32 CB 6 130 C 13`-9 CI 20 C1 12* -S* 32 C7 13'-T 19 Cl C7 15'-10 CI 20 C2 13''-3" 34 C10 13'-1" 19 13'-0" 32 15-1" 33 C8 19-1" 22 18'-3" 35 C9 18-3" 21 C2 ITS 33 C9 130B 14'-2" 18 174" 31 C8 1Z-7" 17 17-7" 30 13'-1"' 17 17-1 D" 30 18 16-W 31 C7 18'-4" 20 18'-1" 33 C8 1TT 19 C2 17'-3" 31 C7 T 130 C 17-5' C1 20 Cl 11' T 31 C7 77-T - .20 Ct C7Cl 21 C2 16=10" 34 1T-0 22 16'-Z 33 C8 174" 33 C10 17-2 20 12'-t" ' 31 14'-0 33 CB 1T 8 22 130 B 13'-3" 18 111T 30 C8 11'-9" 18 _11'-9" 29 - 17-3" 18; 17-1" 29 19 Cl 14--1" 31 CT 1T-2" 20 C2 1T-0" 32 C7 16'S 20 16=2' 30 -C7 8' 130 C 11'-10" 20 C1 Cl 10-10" 31 C7 11'-9 ZD . Cl C721 15'-T 32 C8 11'-T 32 C70 11'x' 2D 11'x" 31 C2 13'-1" 32 16 T 23 15-10•' 34 C8 15-10" 22 130 B 17-T' 19 11-0" 30. C8 11'-7 18 11'-2' 29 11'-T 18 11' 4" . 29 19 133" 30 C7 16"3" 21 CS15'-0" 16-0" 32 C7 ISS 20 1S'-3 31 C79 130 C 11'-3" 21 C1 C1. C7 (1 C722 g14 C2 14-3" 32 C8 11-0" 32 C9 10-9' 21 10'-3" 3D 11'-2" 21 10S 30 17�" 32 158" 23 33 C8 150" 23 130 B 17-0"19 C2 10'-4" 30 C8 10-T' 18 10'-T 29 11'-0 18 10'-9' 29 Ci S," 21-T 32 C7 14'-9" 21 14S 10' 130 C 10'S 21 C1 10'-0" 32 C7 10'-Z' 21 C1 5-9' 30 C7 10'-T 21 C1 9'-1D" 30 C7C2 22 11'-9" 31 14'-10 24 . • 14'-2" 33 CB 14'-2' 23 13-T 130 B 11'x" 19 9'-10' 30 C8 10'-1" 19 10'-1" 29 10'S 19. 10'-3" 29 20 17-0" 31 C7 14'-T 21 14'S 32 C8 14'-1" 21 13-10" 130 C 10-T 22 C2 Ct C7 Ct 23 C2_ C5 13-0 432- ' 9-10" 32 C9 5-9" 21 9-3 31 9'-10 21 9'-0 31 11'-3 31 14'-T 24 13'-T' 32 C7 13'-T 24 130 10-10' 20 W -T Ti- C8 9 8" 19 5-8" 29 91-B" 19 9' 4" 29 11'S 20 11'S 31- C7 14'-1" 22 13'-10" 32 ca 13'S 21 13'-3" 12 _ 130 C 9-9" 22' C2 CZ C7 11'-3" 23 C2 C5 IT -O" 32 13'-0" 24 ' ' 12'4T 9S 33 C10 9�" 22 9-0" -3-1-1C7 9'-1"' 22 8'-3" 31 10 9" 31 13-T 24 614 3x8 x0.042BEAM W/ 615 DBL 3x8x0.042W/ 616 DBL 3x8 x0.042 W/ 12 GA STL INSERT DBL. 14 GA STL INSERT DBL 12 GA STL INSERT ATTACHED FREESTANDING " ATTACHED _ FREESTANDING ATTACHED - FREESTANDING MAX MIN. MAX MIN. MAX MIN.MIN. MAX MIN. MAX MIN. TRIB WIND POST FTG. POST POST FTG. POST POST FTG. POSTN.) G. POST POST FTG. POST POST FTG. POST : WIDTH EXP. SPACING (IN.) TYPE SPACING ON.) TYPE SPACING OR) TYPETYPE SPACING ON.) TYPE SPACING ON.) TYPE r • (SPAN) _ (SPAN) (SPAN) N24�4"38 (SPAN) (SPAN) L. - 5, 13D B 27S 19 C1 27-0' 35 C9 29'-2" 20 CZ7 C11 37-0 21 C5 37S 38 C11 130 C 21'-10' 21 C2 20'-10" 36 C11 57T_ 23 C59 3Z-0" 24 29-4- 40. _ 130 B 20-8" 19 20-0" 34 C8 26'4r 21 36 29'-2" 22 29'-7' 37 + 6. CS C11 C5 C11 130 C 20-0" 22 19'-1" 36 C9 25-9" 24 38 29'-2" 25 26'-10' 39 7' 130 B19-7 20 C2 18' IT 33 C8 24'-8" 22 24'-0" 35 C9 2T-1" 22 r5 2T-1" 36 C11 . 130 C 19-T23 ITS 35 C9 23 ' 0" -1 25 22'-9- 37 C11 2T-1" 25 24'-10" 36 8' 130 B 16-0" 20 C2 1T-8" 33 C7 23'-Z' 22 22'-9' 35 C9 25-3" 23 C5 25'-3" 36 CIO 130 C 1T 4" 23 16_7-,34 C8 27-3" 25 21'-3" 37 C71 25'-3" 26 23'3. 37 C11 NOTES: , 130 B 1T4' 21 16'-8' 32 C7 21'-10' 23 21'S 34 C8 23'-10" 23 23-10" 35 C9 WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL 9 130 C 16'-4" 24, C5 15 T 34 CB 21'-1" 26 C5 20'-1" 36 Cit 23' 10" 26 'CS 7Y 0 37 Cil APPLICATIONS ONLY), THE MAXMUM POST SPACING IS THE LOWEST OF THE _ 130 B 16-1" 21 15-10" 32 20'-5' 23 20'.4'- 34 C8 2Z -r 24 274" 35 C9 ' "MAX POST SPACING(SPAN)" SHOWN ABOVE AND THE MAXIMUM POST i 10 130 C 15-7 24 CS 14.10' 33 20-0' 25C8 - 19'1" 36 1 C9 27S 27 20-10" 36 C11 SPACINGS SHOWN ON DETAIL 6/1.7.1 11' 130 B 15 4" 22 C5 15-2" 32 C8 19' 9 23 C5 19'S 35 C9 21' 8 24 1 21'S 36 C9 130 C 14'-10' 24 14-2" 33 19-1" 27 18'-7 35 21-0 27 19'-10' 36 C11 130 B 14'-9" 22 14W 33 19'-0" 24 18'x. 35 20'-0" ' 24 20-8" 36 CIO 12' CS C8 � � � 130 C 14' Z' 25 13!r 32 18'-3" 27 17'S 35 20'4" 28 19-1" 36 C9 ` s • � ' .. ..... _ ..-,.,.. ....,.. - �. .. .-,mss .. ,.. _ .,.-.,r�r-:, .�. �:.-. 10 2485 RAILROAD ST, - CORONA, CA 92880 951.736.4500 pFESS ICYyyI W S5885 OC TF OF DATE SIGNED: April 5, 2017 Io ,A TCL_ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 1949.305.1150 1 FAX 949.305.1420 • . AHJAPPROVAL r REVISIONS F DATE DESCRIPTION L JOB # 16.1071, DATE - 005117 DRAWNBY RER CHECKED MDS 'IAPM0_'195` V 2.0 `} LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 130 MPH C, L-8-.110.-3-