Loading...
BELC2018-000478-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 C&t!t 4 4V Q" DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760).777-7011 INSPECTIONS (760) 777-7153 Date: 1/23/2018 Permit Type/Subtype: ELECTRICAL/ Owner: Application Number: BELC2018-0004 R CELESTE SHEAFE Property Address: 78595 NAPLES. DR ® 78595 NAPLES DR APN: 609553002 d./�-�� ��=���--a��� QUINTA, CA 92253 Application Description: SHEAFE /TESLA POWERWALS O E BATTERY Property Zoning: Application Valuation: $4,000.00 JAN 2 2 2018 Applicant: CITY OF LA QUINTA Contractor: HOSOPO CORPORATION DBA HORIZON SOLAR POW. 27368 VIA INDUSTRIA STE 101 DESIGN AND DEVELOPMENT DEPARTMENosopO CORPORATION DBA HORIZON SOLAR POW 27368 VIA INDUSTRIA STE 101 TEMECULA,'CA 92590 TEMECULA, CA 92590 (951)537-6859 Llc. No.: 1004233 LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm underpenalty of perjury one of the following declarations: 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, _ I have and will maintain a certificate of consent to self -insure for workers' and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: B. C46 License No.: 1004233 of the work for which this permit is issued. ,// Date: I have and will maintain workers' compensation insurance, as required by Contractor: V� v Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carrier: HDI GLOBAL INSURANCE COMPANY Policy Number: EWGCR000228616 I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any _ _ I certify that in the performance of the work forwhich this permit is issued, I city or county that requires a permit to construct,.alter, Improve, demolish, or repair shall not employ any person in any manner so as to become subject to the workers' any structure, prior to its issuance, also requires the applicant for the permit to file a compensation laws of California, and agree that, -if I should become subject to the signed statement that he or she is licensed pursuant to the provisions of the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division comply with those. provisions. 3 of the Business and Professions Code) or that he or she is exempt therefrom and the n �� basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fora Date: 7, Applicant: permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS VLAWFUL, (_) I, as owner of the property, or my employees with wages as their sole AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO compensation, will do the work, and the structure is not intended or offered for sale. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, apply to an owner of property who builds or improves thereon, and who does the work INTEREST, AND ATTORNEY'S FEES. himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold APPLICANT ACKNOWLEDGEMENT within one year of completion, the owner -builder will have the burden of proving that IMPORTANT: Application is hereby made to the Building Official for a permit subject to he or she did not build or improve for the.purpose of sale.): the conditions and restrictions set forth on this application. (_) I, as owner of the property, am exclusively contracting with licensed contractors 1. Each person upon whose behalf this application is made, each person at whose to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' . request and for whose benefit work is performed under or pursuant to any permit State License Law does not apply to an owner of propefty who builds or improves Issued as a result of this application , the owner, and the applicant, each agrees to, and thereon, and who contracts for the projects with a contractor(s) licensed pursuant to shall defend, Indemnify and hold harmless the City of La Quinta, its officers, agents, and the Contractors' State License Law.). employees for any act or omission related to the work being performed under or (_) I am exempt under Sec. . B.&P.C. for this reason following issuance of this permit. 2. Any permit Issued as a result of this application becomes null and void if work is not commenced within 180 days from date of Issuance of such permit, or cessation of Date: Owner: work for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is correct. I hereby affirm under penalty of perjury that there is a construction lending agency for I agree to comply with all city and county ordinances and state laws relating to building the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). construction, and hereby authorize representatives of this city to enter upon the Lender's Name: above -men toned roperty for Inspection purposes. / Date: Signature (Applicant or Agent): Lenders Address: Date: 1/23/2018 Application Number: BELC2018-0004 Owner: Property Address: 78595 NAPLES DR CELESTE SHEAFE APN: 609553002 78595 NAPLES DR Application Description: SHEAFE /TESLA POWERWALL STORAGE BATTERY LA QUINTA, CA 92253 Property Zoning: Application Valuation: $4,000.00 - i Applicant: Contractor: HOSOPO CORPORATION DBA HORIZON SOLAR POW HOSOPO CORPORATION DBA HORIZON SOLAR POW 27368 VIA INDUSTRIA STE 101 27368 VIA INDUSTRIA STE 101 TEMECULA, CA 92590 TEMECULA, CA 92590 (951)537-6859 -----------------.-----------------------------------------=---------------------------------- LIC. No.: 1004233 Detail: ADDITION OF (1) TESLA POWERWALL 2 STORAGE BATTERY TO EXISTING. ELECTRICAL SYSTEM WITH A 9.01kW PHOTOVOLTAIC SYSTEM + ADDITION OF 200A SUBPANEL. 2016 ELECTRICAL CODE. FINANCIAL ,•. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 • $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 . DESCRIPTION ACCOUNT QTY AMOUNT POWER APPARATUS 101-0000-42403 0 $25.33 DESCRIPTION ACCOUNT QTY AMOUNT POWER APPARATUS PC 101-0000-42600 0. $25.33 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT QTY AMOUNT SERVICES PC 101-0000-42600.0 $13.00 Total Paid for ELECTRICAL: $89.67 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $98.83 Total Paid for PERMIT ISSUANCE: $98.83 DESCRIPTION ACCOUNTQTY AMOUNT ` RECORDS MANAGEMENTTEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 tiln # ofla a Qulntd Building M Safety Division P.O. Box 1504,'76-495 Calle Tampico 6� 14.Quinta, CA 92253 -:(760) 777-7012 Building Permit•Application'and Tracking Sheet Permit # (� Project Address: ,e Owner's Name: ; 5 hk A. P. Number. Address: Legal Description: `( City, ST, Zip: 1—a k t� Contractor: -C) iclephone: Address:Project Description: City, ST, Zip: ) C oZS S. •Q Telephone:. _ Z6 cw :tom State Lia # 0p: City Lic. #; Arch, Engr., Designer: Address: City., ST, Zip: Telephone: , �, . •; _; Construction Type. , Occupancy: State Lie. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: ' Sq Ft.: # Wits: #Units: Telophonc# of Contact Person: Estimated Value of Projcci: l APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Rcq'd Reed TRACKIIVC... PERMITFEES• Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Cluck Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Cates. Pians pleked up Construction Flood plain plan Plans resubmitted Mecharileai Grading plan V Review, ready for corrections ftssue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN HOUSE:- "Review, ready for correctlonsfissue Developer Impact Fee Planning Approval. Called Contact Person A.I.P.P. Pub. Wks. Appr ' Date or permit Issue School Fees 'Dotal Permit Fees �� l) . l �/�o►'�'l scan @ ����-zov1 Sol,r?0 wer d coy" L n RECEIVED JAN 11 2018 CITY OF LA QUINTq COMMUNITY ®EVELOPMENT Powerwall 2 Anchorage Details - US ue V4 r1 POWERWALL INSTALLATION DETAILS IN THE UNITED STATES SS `SHEET TABLE OF CONTENTS 2 GENERAL NOTES SHEET 3 INSTALLATION FLOW CHART 4 BRACKET ATTACHMENT DETAILS TO WOOD STUDS- TUDS-5 5 BRACKET ATTACHMENT DIRECTLY TO METAL STUDS 6 BRACKET ATTACHMENT DETAILS TO METAL STUDS 7 BRACKET ATTACHMENT DETAILS TO CONCRETE/CMU WALL 8 BRACKET ATTACHMENT TO UNISTRUT AT WOOD STUD WALL 9 BRACKET ATTACHMENT TO UNISTRUT AT METAL STUD WALL 10 IBRACKET ATTACHMENT DIRECTLY TO PLYWOOD' TABLE OF CONTENTS SCALE Sheet 03/30/17 N/A 1/10 GENERAL NOTES , 1. ATTACHED DETAILS HAVE BEEN DEVELOPED TO COVER MOST INSTALLATIONS IN THE 50 UNITED STATES. FOR CONDITIONS NOT COVERED HERE, CONSULT WITH A LOCAL ENGINEER OR YOUR TESLA CONTACT. 2. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL FOR EXTERIOR APPLICATIONS. 3. THE MAXIMUM EQUIPMENT WEIGHT IS 275 LBS. 4. THE VALUES OF op, Rp, AND � ARE 1.0, 2.5, AND 1.0 RESPECTIVELY, AS PROVIDED IN ASCE 7-10. 5. THE PEAK GROUND ACCELERATION (SS) USED IN THE CALCULATIONS IS 3.37g.• 6. POWERWALL ANCHORAGE DESIGN HEREIN IS BASED ON THE 2015 INTERNATIONAL BUILDING CODE (2015 IBC) — CHAPTER 16 AND ASCE 7-10 SECTIONS 12 & 13. 7. SNOW LOADS ARE BASED ON TABLE 7-1 AND FIGURE 7-1 PER ASCE 7-10. 8. WIND SPEEDS ARE BASED ON FIGURE 26.5-1A PER ASCE 7-10. 9. WATERPROOFING FOR ALL EXTERIOR APPLICATIONS SHALL BE PROVIDED BY THE INSTALLER/OWNER. 10. OWNER SHALL VERIFY WALL/BUILDING IS STRUCTURALLY ADEQUATE TO SUPPORT POWERWALL UNIT. WHERE OWNER WOULD LIKE TO ADD SUPPLEMENTAL WALL STUDS TO AVOID LOADING EXISTING WALL, AT METAL STUD CONSTRUCTION: USE 21 %2%16 GA. STUDS MIN, W/MAX HT. = 12'-0" AT WOOD CONSTRUCTION: ADD ADDITIONAL WALL STUD TO MATCH EXISTING CONSTRUCTION. 11. SEE FLOW CHART ON PAGE 3 FOR APPLICATION INSTRUCTIONS. TESLA POWERWALL GENERAL NOTES SHEET 03/30/17 SCALE Sheet N/A 1 2/10 WOOD STUD F ANCHORING DIRECTLY TO STUDS ? In POWERWALL ANCHORAGE WALL CONSTRUCTIONTYPE METAL STUD CONCRETE/CMU/BRICK DO YOU HAVE- MINIMUM FsEE DETAIL 18 GA STUDS Cl AND C2 ON SHEET 7 YES NO, OR CANNOT SEE DETAIL BE CONFIRMED MS1 AND MS2 ,ON SHEET 5 ANCHORING INDOOR OR 'OUTDOORS ? SEE DETAIL INDOORS OUTDOORS 17 W1 AND W2 ON SHEEP 4 IS IN WALL BACKING ARE YOU INSTALLING OR FACE—MOUNTED NO THE' UNIT IN HIGH YES ATTACHMENT OR ATTACHMENT DIRECTLY " WIND AREAS" TO PLYWOOD PREFERRED? SEE DETAIL MS5 AND MS6 IN—WALL FACE— MOUNTED PLYWOOD ON SHEEP 6 ATTACHMENT IS IN—WALL BLOCKING OR FACE—MOUNTED SEE DETAIL SEE DETAIL SEE DETAIL P1 ATTACHMENT OR MS3 AND MS4 U3 AND U4 ON SHEET 10 ATTACHMENT DIRECTLY ON SHEET 6 ON SHEET 9 TO PLYWOOD PREFERRED? IN—WALL FACE—MOUNTED PLYWOOD ATTACHMENT. EDETAIL AND EDETAIL W4 UEAND U W3 2 ON SHEET 10 ON SHEET 4 ON SHEET 8 •* HIGH WIND AREAS, WHERE WIND SPEED EXCEEDS 115 MPH PER ASCE 7-10 FIG.26.5-1A: ALABAMA, ALASKA, CONNECTICUT, DELAWARE, FLORIDA, GEORGIA, HAWAII, LOUISIANA, MARYLAND, MASSACHUSETTS, MISSISSIPPI, NEW JERSEY, NEW YORK, NORTH CAROLINA, RHODE ISLAND, SOUTH CAROLINA, TEXAS, VIRGINIA. Y TESLA POWERWALL INSTALLATION FLOW CHART SCALE Sheet 03/30/17 1"=1'-0" 3/10 • •' 1 EXISTING 2x WOOD • WALL STUDS, MIN AT 12" TO 24" SPACING F GYPSUM BOARD OR SHEATHING ' I WHERE OCCURS, TYPICAL E i I I i POWERWALL BRACKET. f POWERWALL UNIT NOT SHOWN FOR CLARITY f MINIMUM 2Y2" PENETRATION � INTO WALL STUDS I *�0- i I 2, ` r I FASTEN BRACKET TO WALL W/ (4)- Y"0 i I i i i I WOOD SCREWS W/ 2J¢" PENETRATION TO I I I I STUDS BEYOND. PROVIDE MINIMUM (1) SCREW ® EACH CORNER f IN ANY HOLE f ♦ /� I 12" MIN I i � �� POWERWALL WALL BRACKET POWERWALL UNIT f WOOD STUD ATTACHMENT: FRONT VIEW W1 WOOD STUD ATTACHMENT: SIDE VIEW W2 EXISTING 2x WALL STUDS MIN AT 12" TO 24" SPACING ` GYPSUM BOARD OR SHEATHING WHERE OCCURS TYPICAL /. E f/ I i f I ' • 2x4 BLKG W/ (2) 16d NAILS INTO EACH END OF BLOCK OR (4)-8d TOE fj NAILS INTO EACH END OF BLOCK TO f WALL STUDS f POWERWALL BRACKET. r i I POWERWALL UNIT NOT f, I I SHOWN FOR CLARITY f co I _ ,, POWERWALL WALL BRACKET " FASTEN BRACKET TO WALL W/ (4)-Y4"0 WOOD SCREWS W/ 2NZ" PENETRATION TO BLOCKING BEYOND. PROVIDE - �, MINIMUM (1) SCREW ® EACH' CORNER r- i 'A — IN ANY HOLE f I I POWERWALL UNIT . f • _ I I 12" MIN MINIMUM 2NZ" PENETRATION f INTO WALL STUDS ` ////`��, d I� WOOD STUD, W/ BLOCKING: FRONT VIEW W3 WOOD STUD, W/ BLOCKING: SIDE VIEW W4 NOTE: SEE GENERAL NOTES ON SHEET 2. TESLA POWERWALL, BRACKETATTACHM ENT TO WOOD STUD SCALE Sheet 03/30/17 1"=1'-0" 4/10 I METAL WALL STUD (MINIMUM 25 GAUGE) I I AT 12" TO 24" SPACING GYPSUM BOARD ' ,,, �'• i OR SHEATHING, I *WHERE OCCURS, TYPICAL'— FASTEN YPICAL FASTEN BRACKET TO BACKING W/ ! µ "" I (8)—#14 SHEET METAL SCREWS. PROVIDE MINIMUM (2) SCREW AT EACH { !2 MIN 1 I '-.CORNER, MIN 3—THREAD PENETRATION i • z ! TYP �' I BEYOND STUD - ! i : ! !t POWERWALL BRACKET.• 'oo! ! "` t i POWERWALL- UNIT NOT ! I SHOWN FOR CLARITY ` ATTACH BACKING TO METAL STUDS W/ 12 1,? s GAUGE 3"x3" ANGLE CLIP OR SIMPSON' I �e ! — u ! SFC2.25 CLIP W/ (2)—#10 SHEET METAL A a i SCREWS IN EACH LEG I' 12" MIN POWERWALL BRACKET j PROVIDE 2)r"x%"x22 GA. BACKING STUD IN WALL WHERE POWERWALL UNIT. POWERWALL BRACKET SLOTS DO NOT LINE UP W/ EXISTING ? METAL STUDS METAL STUD W/ BACKING: FRONT VIEW (NIS 3 METAL STUD ATTACHMENT W/ BACKING: SIDE VIEW METAL WALL STUD / IV (MINIMUM 25 GAUGE) ` I 2" MIN I I AT 12" TO 24" SPACING, I TYPICAL I GYPSUM BOARD _ r/ OR SHEATHING WHERE OCCURS, TYPICAL . .� <kaeo I FASTEN BRACKET TO BACKING W/(12)—#14 HEXHEAD SHEET METAL SCREWS. PROVIDE' ! I MINIMUM (3) SCREWS AT EACH CORNER i X POWERWALL BRACKET. ! I POWERWALL UNIT NOT 12" SHOWN FOR CLARITY co ! ! MIN { i POWERWALL BRACKET V ! 4 i POWERWALL UNIT ATTACH BACKING TO METAL STUDS W/ 12- GAUGE 2GAUGE 3"x3" ANGLE CLIP OR SIMPSON• I .I SFC2.25 CLIP W/ (2)—#14 SHEET METAL I I' I I I SCREWS IN EACH LEG I" PROVIDE-2V'x1Y4"x22 GA BACKING STUDS MIN IN, WALL WHERE POWERWALL BRACKET SLOTS DO NOT LINE UP W/ EXISTING I I II METAL STUDS METAL STUD W/ BACKING: FRONT VIEW MS5 METAL STUD ATTACHMENT W/ BACKING: SIDE VIEW I NOTES: '1. SEE GENERAL NOTES SHEET 2. 2. METAL STUDS SHALL CONFIRM TO ASTM A653' MATERIAL OR. EQUIVALENT W/ MIN YEILD STRENGTH OF 33 KSI ' TESLA .POWERWALL BRACKET ATTACHMENT TO METAL STUD r SCALE Sheet 03/30/17 1"=1'-0" 6/10 FASTENER SCHEDULE "A"* MANUF . MODEL DIAMETER EMBEDMENT SIMPSON. TITEN -Ya„0 1Yz'' . HILTI KWIK—CONN II + Ya„0 1Y POWERS TAPPER'+ 4"0 1Yz * USE FASTENER 'SCHEDULE "B” IF THE POWERWALL CLEAR HEIGHT FROM FINISHED FLOOR IS MORE THAN a 2'-9 AND/OR IF THE GOVERNING JURISDICTION `WHERE THE'POWERWALL IS BEING INSTALLED REQUIRES A FASTENER ESR ;REPORT. (SEE WWW.ICC–ES.ORG) OTHERWISE, FASTENER SCHEDULE "A” IS PERMITTED. 77 -- CMU .CMU OR CONCRETE WALL" . 1)�t MIN.—TYP/ i ! / FASTEN BRACKET TO WALL4- PER 'FASTENER TABLE PROVIDE ��' � (1) SCREW AT EACH CORNER, IN,ANY HOLE i� \/ 00 it r POWERWALL BRACKET. {\ POWERWALL UNIT NOT 'SHOWN FOR CLARITY POWERWALL BRACKET , 12" MIN i POWERWALL UNIT VARIES, SEE FASTENER SCHEDULE NOTES r GROUND SURFACE CONCRETE/CMU ATTACHMENT: FRONTVIEW . C1` " CONCRETE/CMU ATTACHMENT SIDE VIEW ,,C2 NOTE: 1. SEE GENERAL NOTES ON SHEET 2.: 2. CONCRETE, MASONRY, AND BRICK XOMPRESSIVE, STRENGTH SHALL BE 2500 -PSI; 1500 PSI, AND 1700` PSI MINIMUM, RESPECTIVELY." TESLA 'POWER -WALL 'BRACKET ATTACHMENT TO CONCRETE/CMU WALL 03/30/17 SCALE Sheet F. 1"=1'-0" 7/10 FASTENER SCHEDULE "B"*. MANUF MODEL DIAMETER EMBEDMENT ESR# ,- SIMPSON TITEN HD 3/"0 '- 2-Y4" ESR -2713 (CONCRETE) & .ESR -.1056 (CMU) HILTI KH—EZ •.. _ 1 ;.. ESR --3027 (CONCRETE) & ESR`305j6 (CMU) POWERS' WEDGEBOLT + 318"o 1Yz" ESR-2526._(CONCRETE) & ESR7.1678 (CMU) -1 * USE FASTENER 'SCHEDULE "B” IF THE POWERWALL CLEAR HEIGHT FROM FINISHED FLOOR IS MORE THAN a 2'-9 AND/OR IF THE GOVERNING JURISDICTION `WHERE THE'POWERWALL IS BEING INSTALLED REQUIRES A FASTENER ESR ;REPORT. (SEE WWW.ICC–ES.ORG) OTHERWISE, FASTENER SCHEDULE "A” IS PERMITTED. 77 -- CMU .CMU OR CONCRETE WALL" . 1)�t MIN.—TYP/ i ! / FASTEN BRACKET TO WALL4- PER 'FASTENER TABLE PROVIDE ��' � (1) SCREW AT EACH CORNER, IN,ANY HOLE i� \/ 00 it r POWERWALL BRACKET. {\ POWERWALL UNIT NOT 'SHOWN FOR CLARITY POWERWALL BRACKET , 12" MIN i POWERWALL UNIT VARIES, SEE FASTENER SCHEDULE NOTES r GROUND SURFACE CONCRETE/CMU ATTACHMENT: FRONTVIEW . C1` " CONCRETE/CMU ATTACHMENT SIDE VIEW ,,C2 NOTE: 1. SEE GENERAL NOTES ON SHEET 2.: 2. CONCRETE, MASONRY, AND BRICK XOMPRESSIVE, STRENGTH SHALL BE 2500 -PSI; 1500 PSI, AND 1700` PSI MINIMUM, RESPECTIVELY." TESLA 'POWER -WALL 'BRACKET ATTACHMENT TO CONCRETE/CMU WALL 03/30/17 SCALE Sheet F. 1"=1'-0" 7/10 r MOUNT BRACKET TO STRUT W/ (4) Y4"0 HEXHEAC iJ SCREW W/ STRUT NUT. : I 1 %"x 1 %"x 12 GA WALL STRUT ( FASTENED INTO MINIMUM (3) WALL STUDS, WITH. (1) i FASTENER ® EACH STUD. USE Y"O WOOD SCREWS K, ,4 o W/MINIMUM 2Y" PENETRATION INTO STUD. MOUNT ' I BRACKET TO STRUT W/ (4)-Y4"O HEXHEAD SCREW W/ STRUT NUT. i z_ • i _ _ POWERWALL BRACKET. POWERWALL UNIT NOT i i Y SHOWN FOR CLARITY 7 4 g i GYPSUM BOARD OR SHEATHING, WHERE OCCURS TYPICAL 12" MIN EXISTING 2x WOOD WALL STUDS AT 12" TO 24" SPACING UNISTRUT ALTERNATE: FRONT VIEW U1 GYPSUM BOARD OR SHEATHING, WHERE OCCURS TYPICAL POWERWALL UNIT EXISTING 2x WOOD WALL STUDS AT •r �` 12" TO 24" SPACING r POWERWALL BRACKET 41.1 ' -. UNISTRUT ALTERNATE: SIDE VI . EWL@ " NOTES: 1. SEE GENERAL NOTES ON SHEET 2. 6 - 2. ALL WALL STRUTS SHALL BE UNISTRUT P1000 OR.EQUIVALENT. UNISTRUT WOOD STUDS TESLA POWERWALL ♦ SCALE Sheet 03/30/17 • 1"=1'-0" 8/10 1 2'-0" I MAX / II 111 112" ! PLYWOOD i FASTENERS— MAX TMP ( I I - WHERE ATTACHING TO WOOD STUD WALL, ADD ADDITIONAL Y4" WOOD SCREW NEAR EACH CORNER (!I V I I AS SHOWN. t 1 WHERE ATTACHING TO METAL STUD WALL, ADD ADDITIONAL #14 HEX HEAD SHEET METAL SCREW NEAR EACH CORNER AS SHOWN. �I� r Ji" THICK MINIMUM PLYWOOD 00 c POWERWALL BRACKET. POWERWALL UNIT NOT SHOWN FOR CLARITY (l)—#14 WOOD SCREW ® EACH CORNER OF BRACKET, (4 TOTAL).. DRILL SCREW SUCH THAT 1 o I ! �I \ I f t THE SCREW TIP PROTRUDES A MINIMUM OF Y4. 12" MIN I ' ' PAST THE BACKSIDE OF THE PLYWOOD., WOOD OR METAL STUD WALL FRAMING BEYOND t ' BRACKET ATTACHMENT DIRECTLY TO PLYWOOq4P)' TESLA-POWERWALL • BRACKET ATTACHMENT DIRECTLY TO PLYWOOD 03/30/17 SCALE Sheet 1"=1•-0" 10/10 ® r 7100 W. Florida Ave ( Hemet CA 92.545 O I izon 91-1,926.1176 j HorizoE�Solarpnwer.cor:.i S O L..A R P O W' E R E IV ® ' JAN 11 2013 CELESTE SHEAFE -15148 Lighting Loads 78595 NAPLES DR., LA QUINTA, CA 92253 CITY OF LA QUINTA 220-12 Living area sq. ft. 2025 013111MUMAMOPMEDIT 6075 VA 220.52A Two small appliance circuits (required) x 1500 VA 3000 VA 220.52B Laundry circuit (s) 1 x 1500 VA 1500 VA 220.52A Additional small appliance circuit(s) 1 x 1500 VA 1500 VA Lighting Load Subtotal = 12075 VA 220.42 First 3000 volt-amperes of lighting loads @ 100% 3000 VA From 3001 to 120,000 VA @ 9075 35% 3176.25 VA Remainder over 120,000 VA @ 0 25% 0 VA Lighting Load Total Volt -Amperes = 6176.25 VA (A) Appliance Loads 220.55 Household Cooking Applicances (Use.table 220.55) # of Cooking Appliances 1 1000 VA Cooking Units Total Volt -Amperes = 1000 VA ( B) 220.53 Appliance Loads (nameplates) Microwave x 1500 VA 0 VA Compactor x 1200 VA 0 VA Dishwasher x 1200 VA 0 VA Disposal x 600 VA 0 VA Central Vacuum x 1800 VA 0 VA Disposal dish A 0 VA Appliance Subtotal = 7040 VA Appliance Subtotal ( N/A x 75% correction') = 7040 VA (C) 'Correction applied when there are >_ 4 units. If < 4, record subtotal at 100% 422.10A Water Heater A 0 VA ( E ) 220.14 Pool / Spa & Misc (unidentifiable) Loads OF � C IDEP-� Breaker 1T `✓ SAFE Misc 40 XWAG &�?�®j�® 7040 VA (F) ' A��� NS►avUC'(ION 0 VA 0 VA (F) AF0� GO f 0 VA (F) Total Volt-Amperesof((A)(B)(C)(D)( )(A'?,�►�gY 88.57 Amps (G) 220.14C A/C or heating loads D AC1 50 + s41a*v 67a zaet Alan Gillett 1004233,C46 in i Total = 8800 240 45.83 Amps (H) Total Service ( H) + ( G) = 134.40 AMPS sR" • Dn>MTw'n cn nmp wnM n M wnD m n cn D m m I--) C D m m c z n p z w p m m�;J> D p m m c m X p�= 0 M x 0 0= mmcpccCD -ummcT zmm(--=-zi mz-cnopmOmmcZm �m�c�i 0v ��D D W G���m�� �DM M(=m��m-Dj0 A _ xr�7Dmn z n Az��z0p DC(-�w�z����i�cDi�pc�nmz� O-0i O m{z��:L7QD C/)>D--4 OOcnz-izrDn Oi0Cf) - -Z M71c)AM mn=mcmn !! W M-00MU W On cn�A0m-OOo0i0cMM00 M 0,0 -0c czi�0 vDi�mm�z�o�OU) 00mZz00 rn0„ZWOmOwv Mc_- CD �co > DOZOCD� Dn W C -)I= Om mmzzC n�mm�On r -mC�� OOnOmmmOz �- DO -4M m?O �nOD- zcn0Ompm00 M -� O O z rr- Z cn cn Z —i 0 m O O m m 2 � M C M m z m M;Z1 mcm�nO ��O-j0U7 m0�z -M 0 mcn IM13 o�D =-nn r<nC) cnXO cn M pO'�zymmM00mmm mO70Mcncn -� 0O0cn > �n c:"cn>mczj I rT n� mp�0p �O. =w 0zm cn>>Z C -)M �� o zmDm OD MC/) nm cnzr`cnrnzr�0- mem'-� -zG Om�m0cn z 0- X m m m M rnm 0C p m> w n -< z bu a mzODOwmzcnm O�Nm rnm 0zcn�Dw cn c m O ocmiO�MoZn0NZ mZpmo mD nw=ci�zcn D r m o O r o D v O m m rn D O O m z O 0 r 0 0 m rn z M ---i0 70 M zM0 ;10c -"Z ?m AO -H x c/1 cn �w ct)> D W v D O rn n In- 0 -00 m-0 0 m r0 r=�Cmi �� --{ �D m = O 0 m z► p Q n � X 0 cn 0� m g-1* m -i v � 0�o0cZCDn`-mmwOZ M mG>DMDxMx W-1 XZDo T� -z�j� .00x0G0(/)iMooZmDmOOmm= cCa < DOCZi r -i N2 rn Dx Z c� c')Ol D Z 0H M v m 0 m m= D p fTl O` J a rrY mm�0 0-ncn 0G)>C) Cn -( p --j 70 w A=��mG)=mX O m rn 0 n O m _ M N (rn') m m Cmc Z-0 C-) M n O r �cnc;)o70mzc /nn rfl M> 0 C m a p SI D O DO m n (n �OpOmzTmcnOO-Ei-Dm n m� z X(= c A m EZ< z = O m Cc/) m U) 2�� .x 0 � Q T r M -4 x�O-<m0� nmmmn cn fTl wmr���w OO��O U) cf) -I c --A -imwm�mDm v -cnOnO m V y. € O 0 D m m m m m O D z= b m0 0 z O m y X= x m= ' m p 0o A o m �_ z = D r Om D D -0 0 5, 55 0 O � r z m5 -> O* rn O 00 0 4zM-M0-<wMp0cn ' m m m m v z rn -0 m c"� Z� M x W n w U�O0M n_{ �-i n o Z rT! cn<z M n T M 0 O m m CO rn m m m m z p m 0 7 m m M m z xm 0 = M n D 710 Mz in x ID L z I L HOSOPO CORP. OWNER h 7100 W. Florida Ave CELESTE SHEAFE o r i zUHemet, Ca 92545 78595 NAPLES DR. t.,Z (951) 926-1176 �` LAQUINTA, CA 92253 S 0 L A R P 0 W E RCSLB- C -as #1004233 �' ' PHONE: (760) 609-7524 JOB#:15148 78s9,- jwML v' X01 W N Cf) E�: Z Z Z 2 r O ,--. rn z,, -mi D Z -0 -0 CO --A D w D m m z0c-)GO _m M � A D r M U) cf) -I c cf)O� z O y m M O 00 D O y m m o z z W z xm O cn Mz Wm = m c� z zG)m n m z N OO � < O Q°cn D Or m m cOz o z z z m70 <O -A S D g ni �m � �m i> cmo D cn in x ID L z I L HOSOPO CORP. OWNER h 7100 W. Florida Ave CELESTE SHEAFE o r i zUHemet, Ca 92545 78595 NAPLES DR. t.,Z (951) 926-1176 �` LAQUINTA, CA 92253 S 0 L A R P 0 W E RCSLB- C -as #1004233 �' ' PHONE: (760) 609-7524 JOB#:15148 78s9,- jwML v' X01 W N Cf) E�: Z Z Z 2 D--_. rn z,, -mi -0 -0 CO --A D w D m z0c-)GO M � A D r M O U) M N 0> m O X O C5 I- D 0 D m 0 M = c� z zG)m n m z N 0 M r � m r''zz M 20 O o z z D 0 G) --i �U m D cn L.00 dp TESLA POWER WALL SITE PLAN & DATE: 1/9/2018 REVISIONS: _ GENERAL NOTES DESIGNER: S.S. _ SHEET 1 CHECKED BY: X.X Au C Ui zi� *Do y 9. 1 TESLA SPECIFIC NOTES 1. THERE WILL BE A TEMPORARY DISCONNECTION OF SOLAR DURING THIS RELOCATION. CUSTOMER IS RESPONSIBLE TO CONFIRM WITH THE ORIGINAL SOLAR INSTALLER AND/OR SYSTEM OWNER THAT THIS RELOCATION OF THE MAIN POINT OF INTERCONNECTION WILL NOT VOID ANY APPLICABLE WARRANTIES OR VIOLATE ANY APPLICABLE CONTRACTUAL OBLIGATIONS. 2.INSTALLATION OF A CATS HARDWIRED CONNECTION OR POWERLINE CONNECTION FROM ENERGY STORAGE SYSTEM MONITORING HUB TO CUSTOMER'S INTERNET ROUTER. NO WIRELESS CONNECTIONS PERMITTED. 3.COMMISSIONING AND TESTING OF SYSTEM TO INCLUDE A SIMULATION OF GRID OUTAGE WHILE CUSTOMER IS HOME TO SIMULATE PROPER OPERATING EXPERIENCE DURING GRID OUTAGE. REVIEW OF MONITORING PLATFORM WITH CUSTOMER TO SHOW VISIBILITY INTO SYSTEM OPERATIONS VIA COMPUTER AND SMART DEVICES. 4.D000MENTATION AND PERMANENT LABELING OF ALL NEW CIRCUIT BREAKERS INSTALLED IN PROTECTED LOADS PANEL TO IDENTIFY THE CIRCUIT AND APPLIANCES CONNECTED. RELOCATE CIRCUITS TO THE NEW PROTECTED LOAD SUB PANEL WITH INSTALLATION OF ALL NEW CONDUIT, WIRE AND OTHER COMPONENTS AS NECESSARY WITHIN 25' OF EXISTING LOCATION. BRANCH CIRCUIT WIRING MODIFIED, REPLACED, OR EXTENDED MORE THAN 6 FT. SHALL BE REQUIRED TO HAVE AFCI PROTECTION. ART. 210.12(B) ALL WORK SHALL COMPLY WITH NEC (480.1-480.10) AND (690.71-690.85) BATTERY STORAGE SYSTEM NOTES (E) PV SYSTEM: - (34) KYOCERA KU265-6ZPA MODULES (1) FRONIUS PRIMO 7.6-1 INVERTER ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: 2016 CA BUILDING CODE, PART 2 2016 CA RESIDENTIAL CODE PART, 2.5 2016 CA MECHANICAL CODE, PART 4 2016 CA ELECTRICAL CODE, PART 3 2016 CA PLUMBING CODE, PART 5 2016 CA EXISTING BUILDING CODE, PART 10 2016 CA GREEN BUILDING STANDARDS CODE, PART 11 2016 CA REFERENCE STANDARDS CODE, PART 12 2016 CA FIRE CODE BACKFED BREAKERS MUST BE LOCATED @ OPPOSITE END OF BUS BAR FROM MAIN BREAKER OR MAIN LUG ON GRID SIDE. WHEN A BACKFED BREAKER IS THE METHOD OF UNTILITY INTERCONNECTION, BREAKER SHALL NOT READ TINE OR LOAD'. PER CEC 250.64(C): CONDUCTOR SPLICES ONLY ALLOWED WITH COMPRESSION CONNECTORS OR EXOTHERMIC WELDING VERIFY (E) LIFER GROUND NEAR MSP. IF (E) LIFER IS NOT ACCESSIBLE OR VERIFIABLE, INSTALL A NEW 5/8"0 X 8' LONG GROUNDING ROD AND BOND SOLAR SYSTEM EQUIPMENT GROUNDING ACCORDINGLY. CT ------------� I I I 8 I A�q I I 2 I I t00A 1 TESLA POWER WALL 2 - CAT 5 HARDWIRED INTO ROUTER NO WIRELESS CONNECTION PERMITTED —CrLQ b 11 ITY OF LA QUINTA glLDING & SAF\E�TY DEPT. IFOR CONSTRUCTION I DAT BY CT Conductors QPV OEXISTING WIRES 1 200A X 1.2 = 240A (1) POWERWALL BATTERY TOTAL BACKFEED = 26.04A 200A BUS W/ 100A MAIN 1 3 #10 AWGTHWN-2 0.75" EMT 0.0844 16% 1 #10 AWGTHWN-2EGC O 3 #3 AWGTHWN-2 1.00" EMT 0.3285 38% 1 #8 AWGTHWN-2 EGC CT CURRENT TRANSFORMER 1 TESLA CONDUCTORS Q POWERWALL BREAKER 30A 2P BREAKER INCOMING UTILITY SERVICE I M I I 120/240V 1 -PH, 3W TESLA WALL 2 EQUIPMENT QPV BREAKER 40A -2P, 240V 1 200A X 1.2 = 240A (1) POWERWALL BATTERY TOTAL BACKFEED = 26.04A 200A BUS W/ 100A MAIN 1 QSUB 2 PANEL BREAKER 240V QANEL SUB BREAKER 100A 2P BREAKER 1 MAXIMUM ALLOWABLE AMPACITY = 35 TESLA BACK UP SUB PANEL TO MSP WIRE AMPACITY 2016 CEC POWERWALL 2 AC 5KW, 240V, 13.5 KWH 1 TESLA CONDUCTORS Q POWERWALL BREAKER 30A 2P BREAKER 1 2016 CEC 310.15 (8)(3)(a) BACKUP TESLA 200A ATS / METER 1 6 GATEWAY DESIGN AMPACITY = 100 (E) MAIN SERVICE PANEL & 1 QMAIN SERVICE PANEL METER: 200MAIN BUSBAR W/ (N) 150 CENTER FED MAIN BREAKER. QMONITORING TESLA MONITORING UNIT 1 CIRCUITS 30A OR LESS Qg (E) LOADS RELOCATED TO SUB PANEL, TOTAL LOAD NOT TO EXCEED SUB PANEL RATING GATEWAY 1 PANEL BREAKER 100A 2P BREAKER POWERWALL BATTERY BACKFEED CALC: PER NEC A.705.12(D) 5000W / 240V = 20.83A MSP BUS BAR = 200A 20.83A X 1.25 = 26.04A 200A X 1.2 = 240A (1) POWERWALL BATTERY TOTAL BACKFEED = 26.04A LARGEST OCPD: 240A -150A = 90A 65.67A < 90A SOLAR BACKFEED CALC: 31.7A X 1.25 = 39.625A (E) PV TOTAL BACKFEED = 39.625A TOTAL SYSTEM(S) BACKFEED: 26.04A + 39.625A = 65.67A SUB PANEL BACKFEED CALC: 200A X 1.2 = 240A 240A -100A = 140A 40A + 30A = 70A 70A < 140A BATTERY TO BACK UP SUB PANEL WIRE AMPACITY 2016 CEC TABLE THERMAL DERATE FACTOR 310.15(8)(16) 2016 CEC TABLE 310.15(B)(2)(a) NUMBER OF CONDUCTORS2016 CEC 310.15 (13)(3)(a)THWN-2 - 75'C 10 AWG 30 0-3 35 AMPS X 1 X 1 MAXIMUM ALLOWABLE AMPACITY = 35 DESIGN AMPACITY = 30.00 BACK UP SUB PANEL TO MSP WIRE AMPACITY 2016 CEC NUMBER OF THERMAL DERATE FACTOR TABLE 310.15(8)(16) CONDUCTORS 2016 CEC TABLE 310.15(B)(2)(a)(C°) TH WN -2 - 75° C 2016 CEC 310.15 (8)(3)(a) 3 AWG 30 0-3 100 AMPS X 1 X 1 MAXIMUM ALLOWABLE AMPACITY = 100 DESIGN AMPACITY = 100 L1J z :�Ei CV J Q J (D LLJ (D _Q = z Q C!) C� _J I � L.0 o w O Qx J ao C/)� `3 W N_ wo W uI CnU Cn LL,U M N �A VJ N L W U o w u=JUo J co of U3CL Q m LLI LLJ < �ZZLL, � LU 11 u; o m O cw1O°0— O"'' CL) N U Q o O mv�o Nn (L o 0) m LL m in �UCo,U Oo°'°_'m OJ .r. N to U) TYPICAL SYSTEM'CAYOUTS WHOLE HOME BACKUP t_.......__.. .. , �• � � � �_� �Op[ional r Z=. Solar Solar inverter ------------------------- Main panel 7 = S L n ~ Powerwall Whole home t backup s PARTIAL HOME BACKUP Optional f � I ' POWERWALL ; .w Fol Backup Gateway Tesla Powerwall is a fully -integrated AC battery system for Grid ;r residential or light commercial use. Its rechargeable lithium -ion service disconnect y - battery pack provides energy storage for solar self -consumption, ? Gad shifting, and backup. ' '• : Powerwall's electrical interface provides a simple connection to ' any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling s r owners to quickly realize the benefits of reliable., clean power. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS _........... . ....................... __._._._...._... _.................. ---................. _............... -- .... _....... __...... -"---..._..._._.—.....__.._._—_... AC Voltage (Nominal) 120/240 V .............. ..... _._.......... _........ __..... _......... — ..... --.......... _._._...-'- ....--"-'- - ....._....—------- -- ...... —... _ Dimensions 1150 mm x 755 mm x 155 mm (45.3 in x 29.7 in x 6.1 in) Feed -In Type Split Phase •_—_.___._...—..._. _...__...... _... • y . _... _._................ ... _.......... _.................................................................. _...... __..._.............. -... ......... ......... _-.... -••-... -_-_.._....--____-----.._....-__-__....... , Weight 125 kg (276 lbs) GridFrequency 60 Hz ... _..... _-........... -...... ........ ...... _......... _... _......... _....... _.................. .-------- —_._.._._...._..._.. _.... ` --- ---------- - - -- ---- - =— ------- -- - ------------............ Mounting option's Floor or wall mount yam' Total Energy' 14 kWh -._....---...-'---------__.__._—_..._.—_ ....... ---._._-----.._._.._.._.___._...._._..�.._......__.._-__._-- ..----.._...._--....---...._....-..._.._..__..__............_.._.._.._..---.........................._.._.._...._....................._................_........_.._..__.._..................---.........._.._.. Usable Energy' 13.5 kWh 755 mm 155 mm - — (29.7 in) , (6.1 in): Real Power, max continuous 5 kW (charge and discharge) - ---- it Real Power, peak (10s) 7 kW (discharge only) , Apparent Power, max continuous 5.8 kVA (charge and discharge) ... _..... _........ _.......................... ----........... _.......... _..--... -... .......... ....................... .............. .............. __.................. __.... _... _............................................. 1 Apparent Power, peak (10s) 7.2 kVA (discharge only) T = 5 L Pi ._......__.._...._..-----.._.........._.._._.........-----......._._......._.. - - ----....-....--- .._—.......... -- ' - Maximum Supply Fault Current 10 kA L - - - ......-- - ._.._...... - ....-' ......-...._..._......----- .........._...._.. -' -.._.....................----.._.........._........_.._. Maximum Output Fault Current 32A 1150 mm (45.3 in) Overcurrent Protection Device 30 A I{r _..^._.:_.__............._.._..__.-.._......__.... -_.._....._..__..._..:......_......--'-'--........... _._......__..............-'-- .... _............. Imbalance for Split -Phase Loads.........................._..._100%.........................._.................................... ... _......... ... .... Power Factor Output Range +/- 1.0 adjustable - --------------- - --- —— --------- — - ----'---......._ .......... Power Factor Range (full -rated power) +/-0.85 .................... _._....... _.._._.-._._...._.........__....-........_............._........................._._..........._.....---._.................._.............._.__........._._....................._ Internal Battery OC Voltage 50 V t _.... ---- .... .............. --._.._._.._.__...----...... - Round Trip Efficiency' .2 - 90%, ., Warranty to years ENVIRONMENTAL SPECIFICATIONS ' :'Values provided for 25'C (77°F), 3.3 kw charge/discharge power. ........ ­_._.__.-........_._._._...._.... _ __ __. __..__._.._., _..._ ...__ _ _......... ......... .... ..._... - ........ .... _.._ 2 A to battery to AC. at beginning of life. Operating Temperature -20°C to 50°C (-4°F to 122°F) ... .. _.._. ......... _- Operating Humidity (RH) Up to 100%, condensing - Storage Conditions -20°C to 30°C (-4°F to 86°F) - COMPLIANCE INFORMATION - Up to 95% RH, non -condensing ' • State of Energy (SoE): 25% initial _.....__......... . - Certifications ` + UL 1642, UL 1741, UL 19731 __.._-.___.__, ..._._ .- _._.__ _. ._......___.__..._..._......__......._._.. Maximum Elevation - 3000 m ( 9843 ft) • UL 9540, UN 38.3 �. _ .._.� �,•,,.,, ,,;: r .,_.._,._.._..___ _... _...... .............. .................P ... _Y _ _. ................... Environment Indoor and outdoor rated Grid Connection T Worldwide Compatibility Enclosure Type - NEMA 3R .- `• Emissions � FCC Part 15 Class B, ICES 003 • ' a . 4 Ingress Rating IP67 (Battery 8 Power Electronics) Environmental RoHS Directive 2011/65/EU IP56 (Wiring Compartment) Seismic AC 156. IEEE 693-2005 (high) Wet Location Rating Yes ' _ # Pollution Degree Rating PD3 Noise Level @ 1 m . -0 dsA at 30-'f' 86'F) _ +i T = S L n ESLA.COM/ENERGY TYPICAL SYSTEM'CAYOUTS WHOLE HOME BACKUP t_.......__.. .. , �• � � � �_� �Op[ional r Z=. Solar Solar inverter ------------------------- Main panel 7 = S L n ~ Powerwall Whole home t backup s PARTIAL HOME BACKUP Optional f � I ?•' Solar Solar inverter ------------------------- Sub panel Backup Gateway Main panel Utility meter Grid ' y Powerwall Backup loads ! 'Home loads T = S L Pi NLS - BACKUP - 2017-07-17 riESCA.CO. I/ENERGY Fol Backup Gateway Utility meter Grid including service disconnect y ?•' Solar Solar inverter ------------------------- Sub panel Backup Gateway Main panel Utility meter Grid ' y Powerwall Backup loads ! 'Home loads T = S L Pi NLS - BACKUP - 2017-07-17 riESCA.CO. I/ENERGY r POWERWALL Backup Gateway The Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self -consumption, load shifting, and whole - home or partial -home backup. The Backup Gateway controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a circuit breaker, the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall, allowing you to monitor home energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS _..._.._._........_—...._..__.....---...__.....—.........__..__....._........_.__........._................. _....... ........ _.._............... _........... _....... AC Voltage (Nominal) 230 V, 120/240 V Feed -In Type Single 8 Split Phase Grid Frequency ......................... _......... . ............... _..... Disconnect Current 50 and 60 Hz 200 A Maximum Input Short Circuit Current 10 kA Overcurrent Protection Device' 100-200 A; Service Entrance Rated - ..._...---.... - - - --- ------ --- - - ----- ... _.... _....... Overvoltage Category Category III -------- ---------- . ...........---.-............ ... _..__......... _...... _.... _.... __........... -_.... ...... ......... _............ ........... ---............ ............. _... ....... _...... AC Meter Revenue grade (+/- 1 %) MECHANICAL SPECIFICATIONS ....... ......... _........ _........... _._.............. ......... .... _._........ .......... ........ _...._._._.._._._......... - ........ _.._..... ... ,_.. ---- Dimensions 740 mm x 378 mm x 129 mm - (29.1 in x 14.9 in x 5.1 in) -- Weight 16.4 kg (36 lbs) -- Mounting options Wall mount - 378 mm 129 mm (14.9 in) (5.1in) Connectivity ._.... -._......... __.................... _................ _.................... _....._......... Ethernet, Cellular (3G), Wi-Fi _.......... _.................... _..... _.........PP_......................._............................. _.............. ....... User Interface .............. Tesla A -.... ...... - -----...... _..-- .... -_......_..---- Operating Modes - ..--.._.._._—._.-._..— ---... --------._.._.__- Support for solar self -consumption, SPECIFICATIONS load shifting, and backup Backup Operation Automatic disconnect for seamless ---- ---- backup transition -- --- ._.._.... -- -- - ---......... ---..... ....... -.__...... Modularity Supports up to 10 AC -coupled ........ ........ _....... _.... _.._................. _..... _.... -_-...... - ......... ..._ Powerwalls .... ............-- Warranty 10 years Circuit breaker required for installation at service entrance. 740 mm (29.1 in) COMPLIANCE INFORMATION _ ..... —....... ---.................... _._... _.......... _... _.... ...... _......... Certifications _......_............ —................ _..... __................................ _... _......._................ _.... _... - ........ - - UL1642,UL1741,IEC 61000-6-3, - - ENVIRONMENTAL SPECIFICATIONS IEC 62109-1, CSA C22.2.107.1, --------------___.---_.-._-__.__-_--_---. ____..__...-...._._.-..__._.____._._..--_..._ EN 55024, EN 301 489-1, Operating Temperature -20°C to 50°C (-4°F to 122°F) ...... -....... _.._....._.....-_-...----...... . __ ....... EN 301 489-7, EN 301 489-17 Operating Humidity (RH) Up to 100%, condensing Grid Connection -._...__-_.--..__...__..,—._..--..._-.... Worldwide Compatibility _..-........ ..... .---......._.._.._... --..-...._...._._... Maximum Elevation 3000 m (9843 ft) Emissions FCC Part 15 Class B, ICES 003 Environment Indoor and outdoor rated Environmental RoHS Directive 2011/65/EU, Enclosure Type ..-.......................... _......... - .._._._._._..__... NEMA 3R WEEEDirective 2012/19/EU, I .... ..... ...................... ._.....__...__...._........_......_.._.-__-_.._.._._..__...__....._.._...__._,...._,___......._......_._....__:.._.__.....___. _ Battery Directive 2006/66/EC Ingress Rating IP44 Seismic AC156, IEEE 693-2005 (high) Pollution Degree Rating PD3 T S S L n 2017-07-17 -rESLA.COM/ENERGY Step 10: Make AC Power Connections 1. Determine whether the installation requires that neutral be bonded to ground in the Backup Gateway. In most cases, if the Backup Gateway is to be located between the electrical service entrance and the main electrical panel, neutral should be bonded to ground. Otherwise, bonding should be removed. The Backup Gateway ships with neutral bonded to ground. To remove bonding, disconnect the green wire between the ground bar and the neutral terminals. Figure 39: Backup Gateway Ground Bar (top left) Bonded to Neutral (bottom right) 2. Connect the electrical service from the service inlet or from the main panel (depending on the backup configuration) to the Backup Gateway source connection terminals according to the following table and diagram (Fig 40). Strip the ends of the wires and insert them in the corresponding Backup Gateway terminal lugs. Tighten the lugs to 30 Nm (22 Ib -ft). NOTE: For electrical service connections to the Backup Gateway, use 16-120 mm2 (6 AWG to 250 kcmil), 90 deg C minimum copper (Cu) wire. 36 Powerwall Installation Manual IVN Dom°" C Q2e' to 1 Qin 1 paaapet a Source Connection S1 _ S2 L1 L1 L2 L2 N N Load Connections O Figure 40: Backup Gateway Power Connectors (shown with breaker installed) 3. Connect Powerwall to the main or sub electrical panel of the installation (depending on the backup configuration) according to the following tables, for your electrical service type. NOTE: For AC power connections to Powerwall, use 6-10 mm2 (10-8 AWG) 90 deg C minimum copper (Cu) wire. 100 V, 120 V, 200 V, 220 V, 230 V, 240 V Single -Phase Service Backup Gateway AC Wiring Service Connection Backup Gateway Terminal Wire Gauge Line 1 Sl 16-120 mm2 (6 AWG - 250 kcmil) Line 2 S2 16-120 mm2 (6 AWG - 250 kcmil) Neutral N 16-120 mm2 (6 AWG - 250 kcmil) 36 Powerwall Installation Manual IVN Dom°" C Q2e' to 1 Qin 1 paaapet a Source Connection S1 _ S2 L1 L1 L2 L2 N N Load Connections O Figure 40: Backup Gateway Power Connectors (shown with breaker installed) 3. Connect Powerwall to the main or sub electrical panel of the installation (depending on the backup configuration) according to the following tables, for your electrical service type. NOTE: For AC power connections to Powerwall, use 6-10 mm2 (10-8 AWG) 90 deg C minimum copper (Cu) wire. 100 V, 120 V, 200 V, 220 V, 230 V, 240 V Single -Phase Service Main/Sub Panel Breaker Terminal Powerwall Terminal Wire Gauge Line 1 Ll 6-10 mm2 (10-8 AWG) Neutral L2 6-10 mm2 (10-8 AWG) � CAUTION: For single-phase service, Neutral is not connected to the Powerwall N terminal. It is instead connected to the Powerwall L2 terminal. T E S L.,. Fri 37' 120/240 V Split -Phase Service Main/Sub Panel Breaker Terminal Powerwall Terminal Wire Gauge Line 1 Ll 6-10 mm2 (10-8 AWG) Neutral N 6-10 mm2 (10-8 AWG) Line 2 L2 6-10 mm2 (10-8 AWG) 208 V Service Main/Sub Panel Breaker Terminal Powerwall Terminal Wire Gauge Line 1 Ll 6-10 mm2 (10-8 AWG) Line 2 L2 6-10 mm2 (10-8 AWG) 4. On the Powerwall side, strip the ends of the wires and attach them to the corresponding leads on the AC power harness using the provided wirenuts. S. Plug the AC power harness into the AC connector in the Powerwall wiring compartment. Ensure that the connector clicks into place. n41 I�IhII�I' Figure 41: Powerwall 2 AC Power Harness Connection NOTE: The Powerwall connection to the main electrical panel requires a 30 A circuit breaker with a short circuit current rating of 10 kA. This breaker serves as the disconnect for the Powerwall, and must be wired in accordance with local wiring codes and regulations. Powerwall Installation Manual