Loading...
BRES2017-0125r� k 78-495 CALLE TAMPICO ' Ci 0 D �i4NU�iI/ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BRES2017-0125 Property Address: 79195 NUEVO DR f APN: 604273006 Application Description: REESE RESIDENCE / GARAGE CONVERSION Property Zoning: Application Valuation: $20,000.00 Applicant: 9 ROB PITCHFORD 77622 COUNTRY CLUB STE 0 JUL 14 2017 i PALM DESERT, CA 92211 . P 0 CITY OF LA, QUINTA DESIGN AND DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: Date: Contractor: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/14/2017 Owner: SATISH AND JULIE REESE 79195 NUEVO DR LA QUINA, CA 92253 Contractor: OWNER BUILDER Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: OWNER -BUILDER DECLARATION Carr'e : Policy Number: _ I hereby affirm under penalty of perjury that I am exempt from the Contractor's State certify that in the performance of the work for which this permit is issued, I License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any shall not employ any person in any manner so as to become subject to the workers' city or county that requires a permit to construct, alter, improve, demolish, or repair any compensation laws of California, and agr hat, if I should become su ject to the structure, prior to its issuance, also requires the applicant for the permit to file a signed workers' compensation provof Seco 700 of the Lab,/shall forthwith statement that he or she is licensed pursuant to the provisions of the Contractor's State comply with th,,isions s. License Law (Chapter 9 (commencing with Section 7000) of Division 3 ofthe Businessand Professions Code) or that he or she is exempt therefrom and the basis for the Date. lApplicant:,- - aIle d exemption. Any violation of Section 7031.5 by any applicant for a permit ects the applicant to a civil penalty of not more than five hundred dollars ($500).: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, s ' 1, as owner of the property, or my employees with wages as their sole AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO compensation, will do the work, and the structure is not intended or offered for sale. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, apply to an owner of property who builds or improves thereon, and who does the work INTEREST, AND ATTORNEY'S FEES. himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold APPLICANT ACKNOWLEDGEMENT w' in one year of completion, the owner -builder will have the burden of proving that he IMPORTANT: Application is hereby made to the Building Official for a permit subject to r he did not build or improve for the purpose of sale.). the conditions and restrictions set forth on this application. ! s "1, as owner of the property, am exclusively contracting with licensed contractors to 1. Each person upon whose behalf this application is made, each person at whose construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State request and for whose benefit work is performed under or pursuant to any permit issued License Law does not apply to an.owner of property who builds or improves thereon, as a result of this application, the owner,.and the applicant, each agrees to, and shall a contracts for the projects with a contractor(s) licensed pursuant to the defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and ntractors' State License Law.). employees for any act or omission related to the work being performed under or Twho exempt under Sec. .&P.C. for this reason following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not �Dat'e: commenced within 180 days from date of issuance of such permit, or cessation of work OO�nerr IF for 180 days will subject permit to cancellation. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's I certify that I have read this application and state that bove inform ion is correct. I agree to comply with all city and county ordinances an st to laws r atin to building construction, and hereby authorize representatives of th ci y t en er up n the above- mentioned ; rope for inspection purposes. Date: ( 1 Y"3ignature{Applic'�ant or Age~l Owner: SATISH AND JULIE REESE 79195 NUEVO DR LA QUINA, CA 92253 Date: 7/14/2017 Applicant: Contractor: ROB PITCHFORD OWNER BUILDER 77622 COUNTRY CLUB STE 0 { PALM DESERT, CA 92211 Llc. No.: -------------------------------------------------------------------------------------------- Detail: THIRD CAR GARAGE CONVERSION TO A BEDROOM AND BATH -174 SQUARE FEET. TYPE VB CONSTRUCTION, 2016 CODES. *WORK COMPLETED WITHOUT PERMIT - INVESTIGATIVE FEES EQUAL TO THE PERMIT FEES ASSESSED ** NOTE: BUILDING INSPECTOR WILL REQUEST EXITING UNPERMITTED WORK TO BE UNCOVERED FOR INSPECTION. r Application Number: BRES2017-0125 Property Address: 79195 NUEVO DR APN: 604273006 Application Description: REESE RESIDENCE / GARAGE CONVERSION Property Zoning: Application Valuation: $20,000.00 Owner: SATISH AND JULIE REESE 79195 NUEVO DR LA QUINA, CA 92253 Date: 7/14/2017 Applicant: Contractor: ROB PITCHFORD OWNER BUILDER 77622 COUNTRY CLUB STE 0 { PALM DESERT, CA 92211 Llc. No.: -------------------------------------------------------------------------------------------- Detail: THIRD CAR GARAGE CONVERSION TO A BEDROOM AND BATH -174 SQUARE FEET. TYPE VB CONSTRUCTION, 2016 CODES. *WORK COMPLETED WITHOUT PERMIT - INVESTIGATIVE FEES EQUAL TO THE PERMIT FEES ASSESSED ** NOTE: BUILDING INSPECTOR WILL REQUEST EXITING UNPERMITTED WORK TO BE UNCOVERED FOR INSPECTION. r I FINANf IAI INFCIRMATIMI DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $50.66 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $25.33 Total Paid for ELECTRICAL: $75.99 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $38.00 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $25.24 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $5.07 Total Paid for MECHANICAL: $144.31 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAR 101-0000-42401 0 $76.02 DESCRIPTION ACCOUNT QTY AMOUNT FIXTUREITRAP PC 101-0000-42600 0 $38.01 Total Paid for PLUMBING FEES: $114.03 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $45.60 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $103.36 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $141.36 Total Paid for REMODEL: $290.32 DESCRIPTION ACCOUNT QTY ' AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $2.60 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.60 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Sarw im-2.Atas Bin # , - • ..City of La Quinta ' Building 81- Safety Division Permit # i 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7012 Building Permit Application and .Tracking Sheet . `�gt�cs ,\ Project Address: (V Ue �d �P�� -Owner's' Name:S� '� U �.( Cs C A. P. Number: 'Address: q 9 S vLo Jp 1�� Legal Description: City,�ST, Zip:(A a oj,-J U Contractor: C i T elehon e: 6 2Z P D Mmim Address: '� Project Description: -fir �o Sr•� �r •eQ e/ ; L _ City, ST, Zip: �lN 1 4al (rvsclasr •- Telephone: 74. Q -i� Q W StateLic,#: e City Lic.#•: r ISU�Si�� �,,•IY Arch., Engr., Designer: Address: . -VA N City., ST, Zip: one: - Telephone: ...............................:.::::::::::: Can tructi on Type: Occupancy: : a St te Lic. #: Proe Pe � o ct h'circle n w Add'n Alter J o e : New A r Repair r D emo P Name of Contact Person: f eCO�-� rSq. F #Stories: # Units: Telephone # of Contact Person: _ c D —5-49 —6i ZZ Estimated Value of Project: -,S cTDJ • 4D APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, readyfor corrections Plan Check Deposit Truss Cales. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction ' 'Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN IIOUSE:- '"' Review, ready for corrections'/Issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. APPr Date of permit issue School Fees, Total Permit Fees CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date: 5/19/2016 La Qunita, CA 92253 No.: 16-00216-1 (760)771-8515 Owner: Reese Address: 79195 Nuevo Drive City: La Quinta Type: Residential Addition < 500 Sq ft Lot # Street No. Street Name 79195 Nuevo Drive Comments: 0,%FlEa S 20y�y0 r BERMUDA DUNES RANCHO MIRAGE IND WELLS, ~OG .PALM poESERT., y COACHELLA •a ouINTA,.�� p ,IND! Y Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN 158 604-273-006 Exempt Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to - Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 158 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt / Satiha Reese Bank Name/Recipient of Certificate By Dr. Gary Rutherford Superintendent Fee Collected/ Exempted by: ,Kelly,)ones Check No.: Exempt Telephone: 760-578-6122 Funding: Exempt Arfi ;ynt Due $'0.00 Original Paymerit%'s); Recd !;� $0.00 New Payment; . cl $0_0i] - Over n 0.0i]--Over/Ury9$1).00 NOTICE: Pursuant to Govern 'tent Code Seion 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begi to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the Dis rict(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. Bin # Qty Of la QU7nto j Building &r Safety Division 6P.O. Box 1504, 78-495 Calle Tampico !a Quinta, CA 92253 - (760) 777-7012. Building Permit Application and. Tracking Sheet Permit # Project Address: % — ^ ' I G% t �+ l'��fil t Owner's Name:.' MES' A. P. Number. 604 Z; oe2b Address. 79 —1�-r>- Kluruo (tea UE Legal Description: L Cyr j -re 22, 91 7 City, ST, Zip: LA Qt,' t (`1-t;& C,p Contractor: %�.'.�r-.:.:::.;,y..: lily M; ? <;F..`:$• :«l>;.:rr' Telephone: % Z 8� w;,,.;: Address: Project Description: City, ST, Zip: G�1, —g.17C-6C Telephone: State Lie. # : City Lie. #; - Amft.-.SW,, Designer. 10�-_Ag p( TC 0�q�> Address: 7 7 -6 2Z efi►19 j City., ST, Zip. D 9Z24) Telephone: il/ State Lic. #: I�y%•7,✓u•;•��::'•�r'':�y .�:;E•Y- Construction Type: Occupancy: Project type(circle one): New Add'n(IClter Repair Demo Sq. Ft.: I [q' #Stories: I #Units: 1 Name of Contact Person: Qt Telephone # of Contact Person: -760 3 6 2 . 1,r-, Estimated Value of Project: Z0, cx:)Q o 0 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Cates.. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2°' Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted. Grading IN HOUSE:- 'rd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Ful). wus. Appr Date of permit issue School Fees l I I I Total Permit Fees Tjhf 4.4 a" P:'O. Box 1504 LA QUINTA, CALIFORNIA 922474504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760)777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building eimit has been. submitted in your name listing yourself as the builder of the property improvements specified at (' 1) ft � f-- . We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your. responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address .indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. Read and initial each statement below to signs you understand or verify this information. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may, not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers /101, my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the c truction and are not hiring a licensed Contractor to assume this responsibility.' 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my 4. I understand Contractors are required by law to be licensed and bonded in California and to listtheir license numbers on. is and contracts. 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an ".employer" Z6. state and federal law. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll. taxes, provide workers' compensation disability insurance; and contribute to unemployment compensation for. each "employee." I also understand my failure to abide by, these laws may subject me to.serious financial SC7 I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential ures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors. and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 0 8. I understand as an Owner -Builder if I. sell the property -for which this permit is issued, I may be held liable for any finag,cial or personal, injuries sustained. by any "subsequent owner(s) that result from any latent construction defects in the w2plananship or materials. I understand I may obtain more information regarding my,obligations as an "employer" from the Internal_ Revenue Service, the United States Small -Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 8 -321-CSLB (2752) or www.tslb.ca.gov for more information about licensed contractors. 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally, dQ frnancfly r sponsible for . proposed construction activity at the following. address: 11. I agree that, as the party legally and financially responsible for this proposed construction activity, Iwill abide by all e applrcable.laws and requirements that govern Owner -Builders as.well as employers. o notify the issuer of this form immediately of any additions, deletions, or changes to any of the infomration I have provided on this form Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors rimy be in civil court. It is also important for you to understand that if ori unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and. wish to hire Contractors, you will be responsible. for verifvinp whether or not those Contractors are properly licensed and the status of their workers' compensation insurance covers e. Before a building permit can ssued, this form must b completed and signed by the property owner and returned to the.agency responsible for issu' the permit. N te: A. py of the property owner's driver's license, form notarization, or other verification acceptable t th agen is uir to be presented when the permit is issue�,to verify the property owner's signature. Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACTON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign; and file the documents necessary to obtain anOwner-Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: _ Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I .personally filled out the above information and certify its accuracy. Note: A copy of the.owner's driver's license, form notarization, or other verification acceptable to the•agency is required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: Date: Plan Submittal Job Site Building Permit Number. ' Project Desc ' ' - FR Exempt: 0 ( as rdous wastes and are not subject to recycling provisions) Construction Debris Management Plan Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E -Mail Address 6/28/2017 79195 Nuevo Dr. Reese, Satish 79195 Nuevo Dr. La Quinta, CA 92253 Project Manager's Name Rob Pitchford Project Manager's Phone Number 760-346-2856 Project Manager's E-mail Addressi rob.oitchford@gmail.com Builder / Contra Number, Street or PO City, State, Postal C 77622 Country Club Dr., Ste. 0 Palm Desert, CA 92211 Project Square Footage 1 174 z City Approval By Date of City Approval Materials To Be Discarded: Product Tons Trash U Asphalt 0.( Brick/Block 0.( Cardboard 0.( Commingled 0.( Concrete 0.( Drywall 0.1 Donated / Reuse' 0.1 'Describe Items Tons Totals: Rec cle Trash Projected Diversion: 0.61 0.3 1 1 Recyclable Recyclable Recyclable I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the E the property owners) and the owns . retains legal responsibility for ensuring that the provisions of the DMP are to. The eral contractor shall be kept informed of the diversion progress through bi-monthly If uling, all re roiec s ust be taken to an approved recycle or transfer talion. 4�21X77 r / Developer / Project nager iaperintendant Date Not recyclable Product Recyclable Masonry (broken) Recyclable Plaster Recyclable Scrap Metal Recyclable Tile (floor) Recyclable Tile (roof) Recyclable Wood Recyclable Landscape Debris Tons Totals: Rec cle Trash Projected Diversion: 0.61 0.3 1 1 Recyclable Recyclable Recyclable I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued In the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the E the property owners) and the owns . retains legal responsibility for ensuring that the provisions of the DMP are to. The eral contractor shall be kept informed of the diversion progress through bi-monthly If uling, all re roiec s ust be taken to an approved recycle or transfer talion. 4�21X77 r / Developer / Project nager iaperintendant Date BUILDING ENERGY ANALYSIS REPORT PROJECT: The Reese Residence 79195 Nuevo Dr La Quinta, Ca 92253 Project Designer: Robert A. Pitchford 77622 Country Club Drive - Suite O Palm Desert, Ca 92211 e*71.5 2-EI.7 (760) 346-2856 i i�'TY � OF LA QUINTA 130ILDING & SAFETY DEPT. PRO Report Prepared by: CTI o - SLO � DATE I 41a_BY-&t- Santiago Lopez-Ocampol P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 "ECEIVED-N JUN 2 8 2017 CITY OF LA QUINTA Job Number: COMMUNITY DEVELOPMENT PD051817 Date: O*DG� 5/19/2017 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. o :ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIIR-PRF-015- project Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 Page 1 of E 'alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribd16x 3ENERAL INFORMATION Standard Design Proposed Design 01 Project Name The Reese Residence Space Heating 1.29 02 Calculation Description Title 24 Analysis 45.7% Space Cooling 03 Project Location 79195 Nuevo Dr 3.96 2.0% 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.1 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2256 15 Number of Zones 2 16 Slab Area (ft2) 2256 17 Number of Stories 1 18 Addition Cond. Floor Area 174 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 174 21 Glazing Percentage (%) 16.8% ^OMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 1 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.29 0.70 0.59 45.7% Space Cooling 201.58 197.62 3.96 2.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 12.53 12.53 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 -- Compliance Energy Total 215.40 210.85 4.55 2.1% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. New ductwork added is less than 40 ft. in length Registration Number: 217-P010167272A-000.000-0000000.0000 Registration Date/Time: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( l ;A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 :ERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01`x::, 2roject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 Page 2 of F '.alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr- LQ 051817 E+A.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is xovided in the building components tables below. Building -level Verifications: Insulation Inspection .00ling System Verifications: --None -- HVAC Distribution System Verifications: -- None -- Domestic Hot Water System Verifications: --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems The Reese Residence x2256'4 1 4 2 0 1 ZONE INFORMATION 01 `\�02 �..��- - 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Conditioned HVAC Systeml 2082 17 DHW Sys 1 n/a Addition Conditioned HVAC Systeml 174 17 DHW Sys 1 n/a Registration Number: 217-P010167272A-000-000-0000000-0000 ;A Building Energy Efficiency Standards - 2016 Residential Compliance Registration DateTme: 2017-05-19 06:45:40 Report Version - CF1 R-05092017-695 HERS Provider: CaICERTS in( Report Generated at: 2017-05-19 06:34:06 'ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 `', Droject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 Page 3 of f :alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribdl6x OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition (E) Ri/NW Existing Default Wall 1992 to Pres 315 315 30.75 6 90 Existing No (E) Ri/W Existing Default Wall 1992 to Pres 270 Right 394.83 37 90 Existing No (E) Ri/SW Existing Default Wall 1992 to Pres 225 225 30.75 6 90 Existing No (E) Re/S Existing Default Wall 1992 to Pres 180 Back 550.25 167.03 90 Existing No (E) Le/E Existing Default Wall 1992 to Pres 90 Left 438.33 60 90 Existing No Fr/N Existing Default Wall 1992 to Pres 0 Front 272 67.5 90 Existing No Roof N Existing Default Roof 1978 to Pres 922 Existing No Roof S Existing' Default Roof 1978 to Pres 896 Existing No Roof E Existing`, Default Roof 1978 to Pres 132 Existing No Roof `"Existing k Default Roof,1978toPres 132 Existing No Ri/W ",�Addition �.. �`, r R-15 Wall 90 Left 167.58 2.25 90 New N/A Fr/N 2 Addition- '` R-15 Wall 270 Right 92.58 33.3 90 New N/A Roof /Addition R-38 Roof Attic T 51 New N/A Roof W 2 /,Addition R-38 Roof Attic 1 121 New N/A 4TTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Attic RoofExisting Ventilated 4 0.1 0.85 No No Existing No Attic Addition Attic RoofAddition Ventilated 4 0.1 0.85 No No Existing No 2egistration Number: 217-P010167272A-000-000-0000000-0000 Registration Daterrime: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( L% ;A Building Energy Efficiency Standards - 2016 Residential Compliance' Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 'ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Droject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 :alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribdl6x FENESTRATION / GLAZING J CF1 R -PRF -01 Page 4 of f 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition 2030 Fix (E) Ri/NW (- specify --315) -- ---- 1 6.0 0.79 0.70 Insect Screen (default) Existing No 4030 XO (E) RiM/ (Right -270) --- --- 1 12.0 0.79 0.70 Insect Screen (default) Existing No 5050 XO (E) Ri/W (Right -270) ---- --- 1 25.0 0.79 0.70 Insect Screen (default) Existing No 2030 Fix 2 (E) RVSW (- specify -225) ---- ---- 1 6.0 0.79 0.70 Insect Screen (default) Existing No 5050 XO 2 (E) Re/S (Back -180) --- --- 1 25.0 0.79 0.70 Insect Screen (default) Existing No 6068 SGD (E) Re/S (Back -180) ---- ---- 1 40.0 0.79 0.70 Insect Screen (default) Existing No 6050 XO (E) Re/S (Back -180) --- --- 1 30.0 0.79 0.70 Insect Screen (default) Existing No 8068 SGD (E) Re/S (Back -180) ---- ---- 1 53.3 0.79 0.70 Insect Screen (default) Existing No 1616 Fix (E) Re/S (Back -180) ---- ---- 1 2.3 0.79 0.70 Insect Screen (default) Existing No 1616 Fix 2 (E) Re/S (Back -180) - : --- ---- 1 2.3 0.79 0.70 Insect Screen (default) Existing No 1616 Fix 3 "l.''(E) Re/S (Back -180)- ---- ---- 1 2.3 0.79 0.70 Insect Screen (default) Existing No 3040 XO (E) Re/S (Back -180) ---- ---- 1 12.0 0.79 0.70 Insect Screen (default) Existing No 5040 XO (E) Le/E (Left -90) ---- ---- 1 20.0 0.79 0.70 Insect Screen (default) Existing No 5030 XO (E) Le/E (Left -90) ---- ---- 1 15.0 0.79 0.70 Insect Screen (default) Existing No 5020 XO (E) Le/E (Left -90) --- ---- 1 10.0 0.79 0.70 Insect Screen (default) Existing No 5030 XO 2 (E) Le/E (Left -90) ---- -- 1 15.0 0.79 0.70 Insect Screen (default) Existing No 5046 XO Fr/N (Front -0) ---- ---- 1 22.5 0.79 0.70 Insect Screen (default) Existing No 2540 SH Fr/N (Front -0) - -- 1 10.0 0.79 0.70 Insect Screen (default) Existing No 5050 Fix Fr/N (Front -0) ---- ---- 1 25.0 0.79 0.70 Insect Screen (default) Existing No 2540 SH 2 Fr/N (Front -0) ---- -- 1 10.0 0.79 0.70 Insect Screen (default) Existing No 2040 SH RiM/ (Left -90) --- I --- 1 2.3 0.52 0.24 Insect Screen (default) New N/A (2) 2668 FrDr Fr/N 2 (Right -270) - --- 1 33.3 0.32 0.29 Insect Screen (default) New N/A 2egistration Number: 217-P010167272A-000-000-0000000.0000 Registration Date/Time: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( Lo ;A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 :ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 2roject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 :alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribd16x OPAQUE SURFACE CONSTRUCTIONS CFI R -PRF -01 Page 5 of U 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 0.1 None 0.8 No Existing No • Cavity/ Frame: no insul. /2x4 Top Chrd Addition 174 0.1 2x4 Top Chord of Roof Truss @ 24 0.8 No • Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing. Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R -13/2x4 Default Wall 1992 to Pres Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.101 • Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 • Over Ceiling Joists: R-9.9 insul. • Cavity / Frame: no insul. 12x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking j, 2x4 Top Chord of Roof Truss @ 24 • Tile Gap: present Attic RoofAddition Attic Roofs(, `Wood Framed Ceiling in. O.C. none 0.400 • Roofing: 10 PSF (RoofTile) ... _ r -- x._ Inside Finish: Gypsum Board • Cavity/Frame: R -15/2x4 R-15 Wall Exterior Walls Cj.Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.095 • Exterior Finish: 3 Coat Stucco iInside Finish: Gypsum Board Ceilings (below • Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic)' Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Over Ceiling Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ftp) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Existing 2082 0.1 None 0.8 No Existing No Slab -on -Grade 2 Addition 174 0.1 None 0.8 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required -- Registration Number: 217-P010167272A-000-000-0000000-0000 Registration DateTme: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( ;A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 :ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Droject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 :alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribd16x NATER HEATING SYSTEMS CFI R -PRF -01 Page 6 of f 01 02 03 04 05 06 07 08 09 10 11 Heating System _ - Cooling System Solar Name Tank Energy EER SEER Tank Insulation Compressor Type Number of Fraction SplitAirCond Verified Existing Name System Type Distribution Type Water Heater Heaters N Status Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No NATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Heating System _ - Cooling System Name Tank Energy EER SEER Tank Insulation Compressor Type HERS Verification Tank Location or SplitAirCond Heater Distribution Number Volume Factor or Input R -value Standby Loss / Name ' Ambient Name Element Type Tank Type of Units (gal) Efficiency Rating/Pilot (InUExt) Recovery Eff NEEA Heat Pump Type Condition DHW Heater 1 Gas Small Storage 1 50 0.525 EF 28000 Btu/hr n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 1 1 03 04 05 06 07 08 09 Z - Heating System _ - Cooling System Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 Distribution Fan Floor Area Single Speed Verified Existing Name System Type j Name ' Ducted Name Ducted System System •,. Served Status Condition HVAC Systeml Other Heating and / Heating C Yes Cooling Yes Air Distribution. HVAC Fan 2256 Existing No Cooling System mponent 1 Component 1 System 1 1 HVAC - HEATING UNIT TYPES r 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 78 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 9.6 9.7 Not Zonal Single Speed Cooling Component 1 -hers -cool 2egistration Number: 217-P010167272A-000-000-0000000-0000 Registration Date/Time: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( )1 ;A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 :ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD project Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 '.alculation Description: Title 24 Analysis Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribd16x HVAC COOLING - HERS VERIFICATIONx CFI R -PRF -01 Page 7ofI 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Not Required n/a Not Required Not Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 8.0 Attic Attic None Existing + New No N/A Unventilated) IAQ (Indoor Air Quality) FANS 01 ; `� 02 03 04 05 Name – 1 `-�—IAQ CFM ,..••– IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt �. ,.���� 0 Default 0 Not Required Registration Number: 217-P010167272A-000-000-0000000-0000 Registration Date/Time: 2017-05-19 06:45:40 HERS Provider: CaICERTS in( ;A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 06:34:06 :ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD 3roject Name: The Reese Residence Calculation Date/Time: 06:32, Fri, May 19, 2017 'alculation Description: Title 24 Analysis DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Input File Name: 79195 Nuevo Dr - LQ 051817 E+A.ribdl6x CFI R -PRF -01 Page 8 of f Documentation Author Name: Documentation Author Signature: Santiago Lopez-Ocampo company: Signature Date: Santiago Lopez-Ocampo 2017-05-19 06:45:40 4ddress: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 na amity/State/Zip: Phone: La Quinta, CA 92247 760-485-8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business`and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ";:— --1 / 1 ',.-. _ _.,,,,,,,�- 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: ] Responsible Designer Signature: Santiago Lo ez-Ocampo Dompany: Date Signed: Santiago Lopez-Ocampo 2017-05-19 06:45:40 4ddress: License: P.O. Box 1018 NA amity/State/Zip: Phone: La Quinta, CA 92247 760-485-8927 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-P010167272A-000-000-0000000-0000 Registration Date/Time: 2017-05-19 06:45:40 :A Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 ❑ ❑ ❑ HERS Provider: CaICERTS in( Report Generated at: 2017-05-19 06:34:06 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name The Reese Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family 0 Existing+ Addition/Alteration Date 5/19/2017 Project Address 79195 Nuevo Dr La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Z256 Addition 174 # of Units 1 INSULATION Construction Type Cavity Area (ftp Special Features Status Slab Unheated Slab -on -Grade - no insulation 2,256 Perim = 0' Existing Wall Wood Framed R 13 1,682 Existing Roof Wood Framed Attic R 19 2,082 Existing Wall Wood Framed R 15 225 Altered Demising Wood Framed R 15 216 New Roof Wood Framed Attic R 38 174 Altered FENESTRATION Orientation Area(ft) Total Area: 379TGlazing Percentage: 16.8 New/Altered Average U -Factor. 0.33 U -Fac SHGC Overhang Sidefins Exterior Shades Status Right (NW) 6.0 0.790 0.70 none none Bug Screen Existing Right (W) 37.0 0.790 0.70 none none Bug Screen Existing Rear (SW) 6.0 0.790 0.70 none none Bug Screen Existing Rear (S) 167.0 0.790 0.70 none none Bug Screen Existing Left (E) 60.0 0.790 0.70 none none Bug Screen Existing Front (N) 67.5 0.790 0.70 none none Bug Screen Existing Left (E) 2.3 0.520 0.24 none none Bug Screen New Right (Ko 33.3 0.320 0.29 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status HVAC System Ducted Ducted Attic 8.0 Altered WATER HEATING Qty- Type Gallons Min. Eff Distribution Status EnerqyPro 71 by EnergySoft User Number.* 5732 ID: PD051817 Pa a 11 of 16 rV / V rV W• 1 \1VV \VV1MV11 i1M1 1W1M11MMi\/1' \/i1111111M1 J NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. IOrioinal 08/20161 Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011 § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U -factors and solar heat gain coefficient (SHGC) values from TABLES - 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed. § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor must not exceed 0.043. Minimum R-19 or weighted average U -factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.* § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or LI -factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly LI -factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U -factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 permfinch; be protected from physical damage and UV light deterioration; and, when installed as pan of a heated slab floor, meet the requirements of § 110.8(g). § 150.0(8)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(8)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum LI -factor of 0.58; or the weighted average U -factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment IAV IV rVIF• 1\5VV 6 11%3N1 IwoNs 0NNrVIJ ITIVNVN1 VV VN115111N11 § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' § 150.00)28: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)36: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and retum-air ducts and plenums must be insulated to a minimum installed level of R-0.0 (or higher if required by CMC § 605.0) or a minimum installed level of R4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0 m 12. InV I V rVe• 1V1M51MM%V1 ) 1V1VMVM1 VV VM@51111M4 Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with °JA8-2016° or'JA8-2016-E" as specified in Reference Joint Appendix JA8' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with °JA8-2016-E.° § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it ---- lL- [..--a:--I.l.. -t - J:--------- -_ ♦- 0 .I.IA A -.J --..1:-- .. :lL -11 -lL--:- 0 A LA A/1.\A § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item • § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the applicable requirements in 110.9,130.0, 130.2,130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9,130.0, 130.2, 130.4,140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Intemally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of ower as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9,130.0,130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.1 0 b through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. i For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through _ 1 10.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as 'For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name The Reese Residence Date 5/19/2017 System Name HVAC System Floor Area 2,256 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 2,110 42,338 Return Vented Lighting 0 Return Air Ducts 2,444 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,444 TOTAL SYSTEM LOAD 1 47,226 PEAK COIL HTG. Latent CFM 566 789 0 0 566 PEAK Heating System Sensible Output perSystem 80,000 30,489 Total Output Btuh 80,000 Output Btuh/s ft 35.5 1,498 Cooling System 0 Output perSystem 1 0 Total Output Stuh 1 0 Total Output ons 0.0 1,498 Total Output Btuh/s ft 0.0 Total Output s fVron 27,072,000.0 33,486 Air System CFM perSystem 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 1992 - 2005 Fau/AC 0 1 80,000 Airflow cfm/s ft 0.89 80,000 Jan 1 AM Airflow cfm/Ton 24,000,000.0 Outside Air % 0.0% Total Adjusted System Output 0 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside -Air -4 P- 0 cfm 67 OF 67 OF 105 OF 105 OF 10 Heating Coil Supply Fan 2,000 2,000 cfm104 F [ ROOM 68 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/73°F Outside Air 0 cfm 76 / 62 OF 76/62°F 55/54°F 55/54°F Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm 46.3% ROOM n 75 / 61 OF EnergyPro 7.1 by EnergySoft User Number: 5732 ID: PD051817 Pacle 16 of 16