Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-0424 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: 09-00000424 ' 81411 PEARY PL 767-680-023- - - DWELLING - SINGLE FAMILY _LOW DENSITY RESIDENTIAL 627716 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: LARSEN, TERRENCE A 18363 RANCHO SANTA FE DETACHED RANCHO SANTA FE, CA 92091 (760)770-5501 Architect or Engineer: Kass Sr/0.4&4- #16*fs -------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury hat I am licensed under p ovisions of Chapter 9 (commencing with - Section 7000) of Division 3 of the Bu s and Profe ionals C e, and my License is in full force and effect. .�Lic ^n�seClass: 13 Lice No., 673385 Date! 23 ' l ontractor: • OWNER -BUILDER DECLARATION I hereby affirm.under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is riot intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pvrvva i 19 the Cantraatara' Ctm;, Uoo..„o Lu...). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the, work for which this permit is issued (Sec. 3097, Civ. CJ. Lender's Name: _ Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/22/09 Contractor: STROTHER CONSTRUCTION CO, INC-------- 1 NC--- 1 MIRADA CIRCLE RANCHO MIRAGE, CA 92270 D�( (760) 770-5501 0 Lic. No.: 673385 SL:- ----------------------- - - - - -`;,�;zasryxdP----- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0009332-2008 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manners as to become subject to th workers' compensation laws of California, and agree that, if I sho d come suN to the w kers' compensation provisions of Section ,// 3700 of the Labor C e, shall f rthw' comply i provisions. Date:l * 'Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each Person at whose re�uest and for wnoSe oenetit work it lierformed under or pursuani io any permit issued as a result t of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state tha a bove informati is correct. I agree to comply with all city and county ordinances and state laws relating t ' it g cons ruction nd her uthorize r resentatives .off this county to enter upon the above-mentioned p r in ection 'poses. /Date-Z� SIV Signature (Applicant or Age Application Number . . . . . 09-00000424 ------Structure Information 7,237 SF SFD ----- Other struct info . . . -CODE EDITION 2007 # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 1308.00 PATIO SQ FTG 1303.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 7237.00 -------------------------- 2ND FLOOR SQUARE FOOTAGE ------------------------------------------------- .00 Permit . . . BUILDING PERMIT Additional desc 7,237 SF SFD Permit Fee2423.50 Plan Check Fee 1575.28 Issue Date . . . . Valuation . . . . 627716 Expiration. Date . 1/18/10 Qty Unit Charge Per Extension BASE FEE 2039.50 128.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG 500,001-1,000,000 384.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 201.50 Plan Check Fee 50.38 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/18/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 4.00 11.0000 EA MECH FURNACE >100K 44.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 4.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 66.00 8.*00 6.5000 EA MECH'VENT FAN ..52.00 1.00 6.5000 ----=----------------------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . Additional desc . . Permit Fee . . . . Issue Date . . . . Expiration Date . . Qty Unit Charge 7237.00 .0350 LQPERA11T ELEC-NEW RESIDENTIAL 305.56 Plan Check Fee . Valuation 1/18/10 Per BASE FEE ELEC NEW RES - 1 OR 2 FAMILY 72.64 0 Extension 15.00 253.30 LQPERMIT Application Number . . . . . 09-00000424 Permit . . . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension 1113.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 22.26 1.00 15.0000 ---------------------------------- EA ELEC TEMPORARY POWER POLE ------------------------------------------ 15.00 Permit . . . . . . PLUMBING Additional desc . Permit Fee . . . . 444.00 Plan Check Fee 111.00 Issue Date . . . . Valuation 0 Expiration Date 1/18/10 Qty Unit Charge Per Extension BASE FEE 15.00 29.00 6.0000 EA PLB FIXTURE 174.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 30.00 6.0000 EA PLB ROOF DRAIN 180.00 3.00 7.5000 EA PLB WATER HEATER/VENT 22.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00. 14.00 .7500 EA PLB GAS PIPE >=5 10.50 1.00 15.0000 -------------------------------------- EA PLB GAS METER ------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/18/10 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 7,237 SF SINGLE FAMILY RESIDENCE. R-3 OCC. TYPE VB CONSTRUCTION. 2007 CODES. 2008 DIF. **PERMIT DOES NOT.INCLUDE BLOCK WALLS, FENCES, SWIMMING POOLS, SPA, WATER FEATURES and BBQ'S** ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 1069.29 BLDG STDS ADMIN (SB1473) 25.00 DIF COk.U-IU11ITY CDEITDRO-REO 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 157.53 DIF FIRE PROTECTION -RES 140.00 DIF LIBRARIES - RES 355.00 Application Number . . . . . 09-00000424 ---------------------------------------------------------------------------- Other Fees . . . . . . .. DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 62.77 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 3389.56 -------------------- .00 ---------- .00 3389.56 Plan Check Total 1809.30 1564:07 .00 245.23 Other Fee Total 5789.59 .00 .00 5789.59 Grand Total 10988.45 1564.07 .00 9424.38 M LQPERMIT 1,06achellaNalley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Terrence Larsen_ Madison Club, Date: July 23, 2009 Owner's Name: Terrence Larsen Phone No. Project Address: 81-411 Peary Place, LaQuinta Project Description: Single Family Dwelling APN: 767-680-023 Tract #: Lot #'s: Type of Development: Residential XX! Commercial Industrial Total Square Feet of Building Area: 7,237 Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authoriheo to sign on behalf of the owner/developer. Dated: July 23, 2009 Signature: *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code Project 65995 Approval 7,237 sq. ft. $ 3.00 $ 21,711.00 Building Permit Application Completed: Yes/No Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB -181, any room additions of 500 square feet or less on existing dwelling units are exempt from developer fees. iPu'rsuant to AB-181;?any mobile h'r om be_mg re`elloccaatedtoT p acediwithin our schoolydi tr cf is exempt from ;d evelop e'r 'fees. By: Jamie T. Brown, Asst. Supt., Business Services Certificate issued by: Laurie Howard, Secretary III Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (l) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devfees/certificate of compliance form tablesTO USL.doc 1/16/03 T WEDDLE 5 }t SURVEYING MAPPING, INC: ' Boundary • Construction • Topographic • Aerial Surveys • ALTA Surveys • GPS • Consulting September 16, 2009 Mr. Timothy R. Jonasson ` Public Works Director / City Engineer. -City of La Quinta _ 78495 Calle Tampico La Quinta, CA 92253-1504 t Re: Pad/Forin Grade Verification + _ City of La Quinta ' LARSEN RESIDENCE t LL Lot 61A ` Lot 61 Tract No. 33076-1 Peary Place MADISON CLUB S APN 767-680-023 i • Dear Mr. Jonasson: , We have performed a field survey to determine the vertical. location of the Building Pad and -Building Form for the above.referenced project. The elevations observed are as follows:,.,. } PAD (DESIGN) PAD (AS -BUILT) 1002.2 1002.2 FORM (DESIGN) FORM (AS -BUILT) 1002.87 1002:86 ` These field observations are insubstantial conformance: with the Precise Grading -Plan prepared by FEIRO ENGINEERING, INC., dated 09/14/09, approved by the City of La Quinta Building & Safety Department and -the building horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, \,AND S(,� WEDDL SURVEYING MAPPING, INC. !' NO. 55T0 it Ey 'Cy9130109 David -L. Weddle, President L.S. 5570, exp"09/30/09 'q ` 't P.O.-Boz 10418 • Palm Desert, CA 92255-0418 77-725 Enfield Lane, Ste. 140 • Palm Desert, CA 92211 760.360.5570 E -Mail: WedSury@aol:com • Fax 760.360.5573 Earth Systems Southwest' DAILY FIELD REPORT 79-811 B Country Club Drive Bermuda Dunes: California 92203 • (760) 34551588 TIME: WEATHER: " TEMP: 06B,NAME: JOB NO: DATE: Z6 del LOCATION: CLIENT:OWNER: CONTRACTOR: 1 1rC// / PRESENT AT SITE: TEST NO. LOCATION DESCRIPTION ,per. LOT or STATION NUMBER APPROXIMATE ELEVATION Div L �. FIELD TESTING REFERENCE CURVE REQUIRED MINIMUM DENSITY MOISTURE CONTENT % DRY • DENSITY lbs/ cu. ft. RELATIVE.:. COMPACTION % MAXIMUM' DRY DENSITY lbs/cu. ft. OPTIMUM MOISTURE CONTENT %C7 G� 0 r REMARKS: / I v u a c L f r c' oI.� DRAWING per` ci t Vol' 2 C7 /?a �Y19 '• i [��ii (4 <IGt� GT IMITA`IIONS: This report is to provide information regarding the status of the field conditions and our.opinion as to the need for corrective action, additional testing ,I'd or observations. No guarantee or warranty of the contractors work is made or implied. 'chis report is subject to review by the p®ject manager r CLIENT R£PR' SENTATIVE SIGNATURE �'�� \ TECHNICI-kVS SIGNATURE BD -FS -001 (09/03) No. 46774 � � \, L- Certifidate -of Occopancy C 9w� OF ti Building .& .Safety Department - • i {{ f This Certificate is•issued pursuant to the requirements of Appendix Chapter 1 Section 110 of the 2007 California Building. Code, certifying that, at the time of issuance,' this structure was in compliance with the provisions . of the Building Code and the various ordinances -of the City n regulating building construction and/or use. E BUILDING.ADDRESS: 81-411 PEARY PL Use classification: SINGLE FAMILY DWELLING Building Permit -No.: 09-424 Occupancy Group: R-3 - Type of Construction: VN Land Use Zone: RL Sprinklers Installed: NO -Sprinklers Required: NO Occupant Load: 36 i Owner of Building: TERRENCE A. LARSEN 4 . x Address: 18363 RANCHO.SANTA FE - City, ST, ZIP: RANCHO SANTA FE, CA 92091 _.� By: STEVE TRAXEL Building Officia Date: OCTOBER 12, 2010 , �I * 3 POST IN A CONSPICUOUS PLACE k, TITLE 24 REPORT I Title 24 Report for: The. Larsen. Residence. Lot #61A - The Madison Club La Quinta, CA 92253 Project Designer: Steven Ross 42-829 Cook St., Suite 104 Palm Desert, CA 92260 (760) 568-1712 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760)346-0855 == CITYZGA QUINTA BUILDIFETY DEPT. AVED FORRUCTI NJob Number: oaTE1 '24 Date: 4/22/2009 The EnergyPro computer program has been used to perforin the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. Er gyPro 4.4 by EnergySoft Job Number. User Number. 3665 I TABLE OF CONTENTS I Cover Page - Table of Contents Form- CFA R Certificate of -Compliance.. Form MFA R Mandatory Measures Summary Form. WS -5R- Residential. Kitchen. Lighting - HVAC System Heating and Cooling Loads Summary Room Load Summary. Room Heating Peak Loads Room Cooling Peak Loads 1- 2 3- 11 14 18 22 26 1. EnergyPro 4.4 by EnergySoft Job Number. User Number. 3665 Certificate Of Compliance: Residential 7,237 ft2 (Part 1 of 4) CF -IR , 1 e Larsen Residence Project -Titer- Lot I 0 ft2 Slab on Grade Area: 4/22/2009 Date - #61A - The Madison Project Address Chih a_Quanta Number of Dwelling Units: 1.00 Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Documentation -Author Tetephone Plan Check/Date FneravPrp Compli'li ce Method CA Climate 7ona 15 Climate Zone Field CheckM to TDV Standard Proposed Compliance (kBtu/sf=yr)• Design Design Margin Space Heating 2.81 3.88 -1.07 Space Cooling 67.03 55.65 11.38 Fans 9:55 10:1-8 -0:63 Domestic Hot water 3.55 2.90 0.65 Pumps 0.00 0.00 0.00 Totals- 82.93- 72.61. 10.33 - Building Type: -Y Single Family .E] Addition ❑ Multi Family ❑ E)dsting + Add/Aft Building Front Orientation: (N) 0 deg Fuel Type: Natural Gas Fenestration: Area: 1,884 ft' Avg. U: 0.50 Total Conditioned Floor Area: 7,237 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 7,237 ft2 Average Ceiling Height: 12.8 ft Number of Dwelling Units: 1.00 Ratio: 26.0% Avg. SHGC: 0.66 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type HVAC=gl 1t71n 17 1n 014_ Sleeping SleepingStat_ HVAC -92A 92R 4,249 61,610 0.59 Luing LivingStat WAC43 758 7.959 0.10 Sleeping SleepingStat HVAC -!t4 520 5.720 0.07 Sleeping SleepingStBt_ OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tift Roof Wood 1 67A 0 OZfi -38 R--0 0 75 Wall Wood 253 0.064 R-21 R -n 0 an A Wall Wood 304 0-069 R.21 R-0-0 135 _g0 Wall Wood a5 0.069 _R-21 R.A-0 160 gn Wall_ Wood 136 0-069 R_21 R-0-0 225 A Wall Wood 205 0"069 R_21 R-0.0 270 X0 ]Sial)_ Wood' 361 0.-069 * 21 R�0_a A15= -9Q WAR- Wnnd 214 0.069 R.21 R-0.0 Q_g0 Mall- Wood 230 0-089 R_21 R.0.0 45 Qn Roof Weed _4.222 0-025 R_38 R-0-0 75_ 0 Wall Wood- SM in Dag R�21 R -O) -ani-on Wall Wood 51 n obs R_21 R-0 0 135 go IS(ell- wood 102n 0.069 R-21 R-0-0 180 90 r1mL None 24 0.500 Nare R-0-0 lap A0 VM1. Woo& 138. _0.069 -8.-21 R-0.0. 225,-fl0 Wall Wood 1,095 0-069 R.21 R-0.0 270 9 Mll Wood 140 0.069 R-21 R-0"0 315 _g0 Wall Mod _5.94 0089_ R_21 R-0-0 -x_30 ]Mall Whod 351 n -O89 R"21 R -n n 45 A Roof_ Wood 758 0.025 R_38 R-0.0 75 a Wall Wood 492 0.069 R_21 R-0-0 _90 _g0 Wa11 Wood 394 0,069 R.21 R-0-0 180 9 Wall Wood 359 0-069 R_21 R-0-0 270 g0 Wall-- Wood as 0 089 R-21 Rn 0-315 an Wall Wood 310 0.069 R_21 R -0-n _n _a Gains Condition YY / NN Status EN o New Vent Hgt Area -2 n/A 2 n/a -2 nia _2 nia EnergyPfo 4.4 by EnergySoft User Number. 3665 Job Number: Peas:3 of 31 1 Certificate Of Compliance: Residential (Part 1 of 4) CF -1R The Larsen Residence Project Title- 4/22/2009 Da e - Lot #61A -The Madison Club La_Cuinta Project Address Building Permit # RREEZE AIR CONDITIONING (760) 346-0855 Documentation -Author Telephone- Plan Check/Date EneryPro Comph ce Method CA Climate Zone 15 Field Check/Date Climate Zone TDV Standard Proposed Compliance (kBtulsf=yr)- Design Design Margin Space Heating 2.81 3.88 -1.07 Space Cooling 67.03 55.65 11.38 Fans 9.55 10.18 -0.63- Domestic Hot Water 3.55 2.90 0.65 Pumps 0.00 0.00 0.00 Totals- 82.93- 72.61- 10.33 Percent better than Standard: 12.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: -Y Single Family El Addition Total Conditioned Floor Area: 7,237 ft2 ❑ Multi Family ❑ Fydsting + Add/Aft Existing Floor Area: n/a ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 7,237 ft2 Fenestration: Average Ceiling Height: 12.8 ft Area: 1,884 ft' Avg. U: 0.50 Number of Dwelling Units: 1.00 Ratio: 26.0% Avg. SHGC: 0.56 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area OPAQUE SURFACES Insulation. Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tift Wall Wood i6 _n Qsg_ R-21 R-0-0 _4-5 An Root Weed 520 00255 R_38 R-0-0_ 75 Wall. Wood 233 a-069 R_21 R-0-4) 90__gQ wall Wood 304 n Q$9_ R_21 R-0 0 1 A0 An wall Weed 236 0-069 R_21 R-0-0 270 9 Wail Wood 46 0-069 R-21 R-0-0 _3.15_-9Q Wall Wood 134 n ON —21 R.0 0 _n An WAIT Wood 22 n 069 _R-21 R -n n 45 9Q Gains- Condition - Y / N Status JA IV Reference WAI Location / Comments Run Initiation Time: 04/22/09 09:02:39 Run Code: 1240408969 EnergyPro 4.4 by EneMySd t User Number. 3665 Job Number: Page:4 of 31 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R The Larsen Residence ProjetYTitte Data 4/22/2009 FENESTRATION SURFACES True Gond, # Type Area U -Factor' SHGC2 Azm. Tift Stat. Glazing Type Exterior Shade Type Location/ Comments J- Skylight Left (F) 16.0 1-47016-A-0 Z6 1J&B _25_ 0 New Skylight REA Dist Len. H91. Dist. Len. Hg - ZONE #1 2 Skylight Left (E) 16.0 1.470 116-A 0_76 116-8 75 0 New Skylight ZONE #1 3 Window Left (E) 54.8 0.450 NFRC 0_52 NFRC 90 90 New Loewen Dbl Or (Csmt) (D7) ZONE #1 4 Window Left (E)- 1.5 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Cir (Fxd) (R3). ZONE #1 5 Window Left (E) 1.5 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Or (Fxd) (R4) ZONE #1 6 Window Left (E) 1.5 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Cir (Fxd) (R5) ZONE #1 7 Wndow Left (E) 1.5 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Clr (Fxd) (R6) ZONE #1 8 Window Left (E) 1.5 0.500 NFRC 0.67 NFRC 90 90 New Loewen Dbl Or (Fxd) (R7) ZONE #1 3 Window Left (SE) 12.5 0.5Q0 NFRC 0,67 NFRC 135 _90 New Loewen Dbl Or (Fxd) (Ll) ZONE #1 1Q Window Left (SE) 32.0 0.450 NFRC 0.53 NFRC 135 90 Now Loewen Dbl Cir (Csmt) (01) ZONE #1 11 Window Left (SE) 12.5 0.500 NFRC 0_67 NFRC 135 90 New Loewen Dbl Clr (Fxd) (L2) ZONE #1 12 Window Left (SE) 8.8 0.500 NFRC 0_67 NFRC 135 90 New Loewen Dbl Or (Fxd) (P7) ZONE #1 :U 14 Window- Window Rear- Right (S"- (NW) 32..0 20.0 0.5 -NFRC 0.6Z NFRC 225 --2(L New Loewen-f)b1C1r-(Exd)(Q1)- 0.480 NFRC 0.59 NFRC 315 90 New Loewen Dbl Or (SGD) (130A) Z0NE#1 ZONE #1 15 Window Front (N) 30.0 0.450 NFRC 0.52 NFRC 0 90 New Loewen Dbl Cir (Csmt) (Al) ZONE #1 16 Window Front (N) 108.8 0.450 NFRC 0.52 NFRC 0 90 New Loewen Dbl Or (Csmt) (E1) ZONE #1 1_7 SkyUW Left (E). 27.0 1.470. 1.16A. 0_76 a 1s -e 75 0 New. Skylight. 0.76 ZONE #2 18 Window Left (E) 30,0 0.450 NFRC 0.52 NFRC 90 90 New Loewen Dbl Or (Csmt) (A2) ZONE #2 -M Window Left (E) 48.0 0.450 NFRC 0.34 NFRC 90 90 New Loewen Dbl Or (SwngDr) (109A) ZONE #2 1. Indicate source either from NFRC or Table 116Aa 2. Indicate source either from NFRC or Table 1160. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist Len. H91. Dist. Len. Hg - t -1- None 1.00 2- None. 1.00. _ 3 Bug Screen 0.76 9.0 6.1 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 - 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 - 9 Bug Screen 0.76 - - 10 Bug Screen 0.76 11 Bug Screen 0.76 - 12 Bug Screen 0.76 13 Bug Screen 0.76 -_ -_ 14 Bug Screen 0.76 8.0 2.6 10.0 0.1 10.0 10.0 15- BW Screen- 0.76- 5:0- 6.0 2:0 0:1 2:0- 2.-0- 16 Bug Screen 0.76 9.0 12.1 2.0 0.1 2.0 2.0 17 None 1.00 18 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 19. Bug -Screen. 0.76 - THERMAL MASS FOR HIGH MASS DESIGN Area_ Thick. Heat Inside. Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length- R -Vat: Location JA IV Reference- Status- Comments Slab Perimeter 442 None No Insulation 26 -Al New ZONE #2 Slab Perimeter 198 None No Insulation 26 -Al New ZONE #3 Stab Perimeter 101 None No Insulation 26-A4 New ZONE #4 Run Initiation Time: 041=09 09:0 :39 Run Code: 1240408959 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page:5 of 31 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R The Larsen Residence 4/22/2009 Project -Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGCZ Azm. Tift Stat. Glazing Type 2. Indicate source either from NFRC or Table 116B. Window Overhang Hgt. Wd. Len. Hgt LEA Location/ Comments 2Q, Window Left (SE) 48-0 0.500 NFRC 0A NFRC X35_ _0_ New Loewen Dbl Or (Fxd) (Sar) 0.1 2.0 ZONE #2 21 Window Left (SE) 6.0 0.500 NFRC 0.67 NFRC 135 90 New Loewen Dbl Clr (Fxd) (M5) ZONE #2 22 Window Rear (S) 300.0 0.480 NFRC 0_59 NFRC 180 90 New Loswen Dbl Or (SGD) (127A) ZONE #2 23. Window Rear (SWI. 48.0 0.50 NFRC 0_67 NFRC 225 90 New Loewen Dbl Cir (Fxd) (GI). ZONE #2 24 Window Right (W) 24.0 0.500 NFRC 0.67 NFRC 270 90 New Loewen Dbl Clr (Fxd) (H1) ZONE #2 25 Window Right OM 24.0 0.450 NFRC 0_34 NFRC 270 90 New Loewen Dbl Or (SwngDr) (141 A) ZONE #2 26 Vlrindow Right OM 24.0 0.500 NFRC 0`67 NFRC 270 90 New Loewen Dbl Cir (Fxd) (142) ZONE #2 27 Window Right (W) 108.8 0.450 NFRC 0.52 NFRC 270 90 New Loewen Dbl Cir (Csmt) (E3) ZONE #2 2()._Window 0.76 Right OM 6.0 0.500 NFRC 0.67 NFRC 270 9_ New Loewen Dbl Clr (Fxd) (Ml) ZONE #2 2.0 Window Right (1M 25.0 0_450 NFRC _Q,25 NFRC 270 90 New Loewen Dbl Clr (Csmt) (131) ZONE #2 30 Window Right ()IIA 18.0 0.500 NFRC 0_67 NFRC 270 90 New Loewen Dbl Clr (Fxd) (CI) ZONE #2 31 Window Front (N) 200.0 0.480 NFRC 0_59 NFRC 0 90 New Loewen Dbl Or (SGD) (127B) ZONE #2 3t 33 - Window Window Front Front (j) (N) 37:5 0 NFRC- 0.67 NFRC 10 108.8 0.450 NFRC 0.52 NFRC 0 _1q(L New Loswen-0b] Ctrjftd)-(L1) 90 New Loewen Dbl Cir (Csmt) (E2) ZONE #2 ZONE #2 34 Wndow Front (NE) 120.0 0.480 NFRC 0_59 NFRC 45 90 New Loewen Dbl Clr (SGD) (123A) ZONE #2 35 Window Front (NE) 30.0 0.450 NFRC 0_52 NFRC 45 90 New Loswen Dbl Cir (Csmt) (A3) ZONE #2 36. Window. Front (NE). 48.0. 0.450. NFRC. 0_34 NFRC 45. 90. New. Loewen Qbl. Clr (SwngDr).(.103A)- ZONE #2 37 Window Rear (S) 10.0 0.500 NFRC 0_67 NFRC 180 90 New Loewen Dbl Clr (Fxd) 03) ZONE #3 $$ Wndow Rear (S) 10.0 0.500 NFRC 0.67 NFRC 180 90 New Loewen Db) Cir (Fxd) (A) ZONE #3 1. Indicate source either from NFRC or Table 116A INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 2. Indicate source either from NFRC or Table 116B. Window Overhang Hgt. Wd. Len. Hgt LEA Left Fin Right Fin REA Dist Len. Hgt. Dist. Len. Hgt 20 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 21. Bug -Screen. Q78. 22 Bug Screen 0.76 10.0 30.0 6.0 0.1 6.0 6.0 23 Bug Screen 0.76 8.0 6.0 2.0 01 2.0 2.0 - 24 Bug Screen 0.78 8.0 3.0 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 8.0 3.0 2.0_ 0.1 2.0 2.0 - 28 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.78 8.0 12.1 2.0 0.1 2.0 2.0 - 28 Bug Screen 0.76 29 Bug Screen 0.78- 30 Bug Screen 0.76 31 Bug Screen 0.76 10.0 20.0 10.0 0.1 10.0 _ 10.0 32 Bug Screen 0.76 7.6 5.0 10.0 0.1 10.0 _ 10.0 33 Bug Screen 0.76 9.0 12.1 2.0 0.1 2.0 2.0 34- Bug Screen- 0:76 10U 12.0 10.0 0.1- 10.0 _ 10.0 35 Bug Screen 0.78 36 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 37 Bug Screen 0.76 _ 38- Bug -Screen. 0.76 _ - THERMAL MASS FOR HIGH MASS DESIGN Area. Thick. Heat Inside. Condition. Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R-Vaf: Location JA -IV Reference- Status- Comments Run Initiation Time: 04/22/09 09.02.39 Run Co -de: 1240408969 EnergyPro 4.4 by EnergySoft User Number. 36155 .lob Number. Page:6 of 31 Certificate Of Compliance: Residential (Part 2 of 4) C_ The Larsen Residence 4/22/2009 Project Title Date FENESTRATION SURFACES True Gond, # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments 3R Window Rear 10n _0_50 NFRC 06 NERC 180_ _90_ New Loewen Dbl Or (Fxd) (,1,S) ZONE #3 40 Wndow Right �(S) (W) 25.0 0.450 NFRC 0_52 NFRC 270 90 New Loewen Dbl Or (Csmt) (B2) ZONE #3 41 Window Right (W) 52.5 0.500 NFRC 0_67 NFRC 270 90 New Loewen Dbl Or (Fxd) (St) ZONE #3 42. Window Front (N). 48.0 0.450 NFRC 0.34 NFRC 0 90 New Loewen Dbl Or (S1wngDr) (104A) ZONE #3 43 Window Left (E) 6.0 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Or (Fxd) (M4) ZONE #4 44 Window Left (E) 1.5 0.500 NFRC 0_67 NFRC 90 90 New Loewen Dbl Cir (Fxd) (R2) ZONE #4 45 Window Left (E) 1.5 0.500 NFRC 0.67 NFRC 90 90 New Loewen Dbl Or (Fxd) (R1) ZONE#4 46 Window Rear (S) 10.0 0.500 NFRC 0.67 NFRC 180 90 New Loewen Dbl Or (Fxd) (A) ZONE #4 A7 Window Rear (S) 100 _0.500 NFRC 0.67 NFRC 180 90 New Loewen Dbl Clr (Fxd) (J2) ZONE #4 g$ Window Right " 48.0 0.450 NFRC 0 r NFRC 315 90 New Loewen Dbl Clr (Csmt): (G2) ZONE #4 49 Window Front (N) 20.0 0.450 NFRC 0_34 NFRC 0 90 New Loewen Dbl Or (SwngDr) (146 -Al ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Wkidow Overhang- Left Fin Right Fin - # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist Len. Hgt Dist. Len. Hgt 39 Bug Screen 0.76 40 Bug Screen 0.76 _ 41- Bug -Screen. 0.76 42 Bug Screen 0.76 - 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bun Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 _ 48 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 _ 49 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments I EneraPro 4.4. by. EnergySoit. User_Number.3M Job -Number: Paae:.7 of 31. I Certificate Of COMElliance : Residential . (Part 3 of 4) CF -1 R The Larsen Residence Tank Energy- Duct Duct Condition 4/22/2009 Project -Title Heating Cooling Location Date Tested? HVACat1 HVAC SYSTEMS Ducted Attic 4.2 New Yes HVAC4J2A &2B Ducted Ducted Heating Minimum Cooling Minimum Condition Thermostat Location- Type Eff Type Eff. Status- Type HVAC -#1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC412A ii2B Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC -#3 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS - Rated Tank Energy- Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVACat1 Ducted Ducted Attic 4.2 New Yes HVAC4J2A &2B Ducted Ducted Attic 4.2 New Yes HVAC43 Ducted Ducted Attic 4.2 New Yes Hydronic Piping pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS - Rated Tank Energy- Tank lnsut: Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A.O.Smith FGR -75 Large Gas No Pipe Insulation 3 76,000 75 New 0.72 0.00% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control. # HP Type ln.Plenum. Outside. Buried. Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that'compliance using duct design, duct seating, verification of refrigerant charge and-TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Tdle/Fnn: Steven Ross Address: 42-829 Cook St., Suite 104 Palm Desert, CA 92260 Telephone: (760)568-1712 tic. M. (signature) (date) Enforcement Agency Name: Title/Finn: Address: Telephone: (signature) (date) Documentation Author Name: CJ McFadden Title/Finn: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: 760 346-0855 • (signature) (date) BREEZE Act CONDITIONING' INC Certificate Of Comaliance : Residential _Part 3 of 4) CF -1 R The Larsen Residence 4/22/2009 Project-Titte Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location- Type Eff Type Eff. Status- Type HVAC44 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Dud Dud Condition Duds Location Heating Cooling Location R -Value Status Tested? HVAC -#4 Ducted Ducted Attic 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standbyy R=Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control. # HP Type In.Plenum. Outside. Buried. Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using ductdesign, duct sealing, verification of refrigerant charge and TXVs, insulation instaflation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Finn: Steven Ross Address: 42-829 Cook St., Suite 104 Palm Desert, CA 92260 Telephone: (780)568-17-12 Uc.#s (signature) (date) Documentation Author Name: CJ McFadden Title/Firm: BREEZE AIR CONDITIONING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 Telephone: 60 346 -0855 - (signature) (date) Enforcement Agency Name: d Q Title/Finn: d Address: d� BREEZE Telephone: AIR CONDITIONING. INC— (signature) NC (signature) (date) En Pro 4.4 by En Soft User Number. 3665 Job Number: Pa e:9 of 31 Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R The Larsen Residence 4/22/2009 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified In this checklist These items reeuire special written justification and-rlocurnemta km -and special verification to be used with the performance approach.- The -local. anforcarnent anenev detarminas the adeouacv of the Justification. and may relect a building or design that otherwise complies Used on the adequacy of the special justification and documentation submitted. Plan I Field The Roof "R-38 Roof includes a Radiant Barrier. The HVAC System "HVAC41" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC42A &2B" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas - The HVAC System "HVAC43" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC44" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification Items In this section require field testing andfor verification by a certified home energy rater under the supervision of a HERS-providerustng approved testhmg-andlorverification methods: I Pian I Field The HVAC System "HVAC41" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented or the CF - 4R. The HVAC System WAC41—ihoorporates a HERS verified Refrigerant Charge test or a HERS verifled-Thermostafic Expe nsion Valve. The Cooling System "PSA2BD / PGC1 RA (5 Ton) 14 SEER" includes credit for a 12.4 EER Condenser. The HVAC System "HVAC -#2A &2B" incorporates HERS verified Dud Leakage. Target leakage is calculated and documerted on the CF -4R. The HVAC System "HVAC -#2A &2B" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (5 Ton) 14 SEER" Includes credit for a 12.4 EER Condenser. The. -HVAC. System "HVAC -#3" incorporates HERS. verified -Duct I eak go. Target leakage.is-calculated and documented -on the CF - 4R. The HVAC System "HVAC,93' inowporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA28D / PGC1 RA (5 Ton) 14 SEER" includes credit for a 12.4 EER Condenser. The HVAC System "HVAC44" incorporates HERS verified Dud Leakage. Target leakage Is calculated and documented on the CF - 4R.. The HVAC System "HVAC -#4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (2 Ton) 14 SEER" includes credit for a 13.3 EER Condenser. EnerWAIm 4.4 byEneigySoft User Number. 3665 Job -Number. Page: 10of 31 t Mandatory Measures Summary: Residential (Page 1 of 2) MF -111 NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance sequirernenWhomOre.CertiflcateW.CompUanoesupercedetheAemsmadced.withanadedsk(')below . Whenthis.chee*fl Js3noogwratedJrNoJh8-penrnit- documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checkfist only. I�ESCRiPTION Check or Initial applicable boxes or check NA If not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE- MENT Building Envelope Measures ❑ ❑K ❑ § 150(a): Minimum R-19 in wood celling insulation or equivalent U -factor in metal frame ceiling.. ❑ FRI ❑ § 150(b): Loose fill insulation manutactwWs labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wail insulation in wood framed wags or equivalent U4actor in metal frame walls (does not ❑ a ❑ appy to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent tlfactor. ❑ ❑ ❑ installation of fireplaces; Decorative Gas Appliances and Gas togs.- ogs.1. ❑ ❑K ❑ 1.Masonry and factory -built fireplaces have: ❑ ❑K ❑ a. ctosabte metal or glass door covering the entire opening of the firebox ❑ ❑K ❑ b. outside.airintake with -damper mW control, flue damperandcontr6l. ❑ ❑ 2. No continuous burning gas pilot tights allowed. ❑ 0 ❑ § IMM: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 1500): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3W water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 pertMnch. § 110: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -611 Form: § 116-17: Fenestration Products, Exterior Doors, and Infliration/Exfilbation Controls. j] ❑X ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ N 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ 1K ❑ Coefficient (SHGC). and infiltration certification. ❑ Q ❑ 3. Exterior doors and windows weathersbipped; all joints and penetrations caulked and sealed. ❑ N ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑K ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑K ❑ § 150(1): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 ❑ § 150(§: Water system pipe and tank insulation and cooing systems line insulation. 1. Storagegas water heaters rated with an Energy. Factor less than 0.58 must be eudemally.wrapped with insulation ❑ ❑K ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other Indirect hot water tanks have R-12 external ❑ ❑K ❑ Insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R-vatue. 3: The following piping is insulated'according to Table 154AIB or Equation 1513A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, norm -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and j] ❑X ❑ indirect hot water tank shall be insulated to Table 1549 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123•A. ❑ ❑ ❑ S. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ Q ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping Includes a vapor retardant or Is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number: Page:I I of 31 Mandatory Measures Summary: Residential (Page 2 of 2) MF -IR NOTE: Lewrisa residential bull iAga subject to the Standards must Domain these mea$ures regardless of the aompfooe appMaeh used. More stringent compliance -requirements trom the -Cer6ttrace of.Compllance supercede t **ems marked with an.asterisk (*) below vuhen this checklist is Incorporated Into the permit. documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere In the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) §. 150(m): Duds and Fans 1. All ducts and plenums Installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 65; supply -air and retum-atr duets and plenums are Insulated to a minumum installed level of R4.2 or endosed entirelyin conditioned space. Openings shall be sealed with mastic, tape or other duct-losure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. tf mastic or tape Is used to seal openings greater than 174 inch, the combination of mastic and efther mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain duds. Ducts Installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of dud systems and their components shall not be sealed with doth back rubber adhesive ❑ ® ❑ dud tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ Q ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ © ❑ S. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. and have an output frequency no less than 20 kHz. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ FX] ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ 7. flexdbte-ductscannottaveporousinnercores: ❑ 0 ❑' § 114: Pool and Spa Heating Systems and Equipment § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ 1. A thermal efficiency that compiles with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating. instructions, no electric resistance heating and no pilot light locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 2. System is installed with: ❑ ❑ ❑ Ughting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. a. At least 36' of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ Q ❑ burning pilot fight (Exception: Novi -electrical cooking appliances with pilot < 150 Bttdhr) § 118 (p: Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures §_ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only. high efficacy lamps as outlined in Table ❑ X❑ ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ © ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as detennined ❑ FX] ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensors) cerified to comply with Section 119(d). § I50(k)4: Permanently installed luminaires located other than in kitchens bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (exceptclosets less than 70 ft) OR are controlled by a dimmer switch OR are oonboited ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ ce, bfled to ASTM E283and labeled as airtight (AT) to less em20 -CFM at 76 Pascats: § 150(k)8: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poohkWater features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Uahting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Ughting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, nondweliing spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section I I9(d).. EnergyPro 4.4 by Energysoft User Number: 3665 Job Number. Page: 12 of 31 Residential Kitchen Lighting Worksheet WS -SR The Larsen Residence 4/22/2009 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens -must be in luminaires that are high efficacy lu-rin'aires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts High Efficacy Quantity Watts Other Watts (1) 2 It Fluorescent T8 EIeC Yes X No 22.0 x 2 = 44 or (1) 26w Compact Fluorescent Triple 4 Pin Yes X No 1 1 37.0 x 20 = 740 or (1) 4 It Fluorescent T8 Elec Yes No IXI 32.0 x 2 = or 64 50w Low Voltage Halogen Yes No X 55.0 x 6 = or 330 Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or Yes No I I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 784 B: 394 COMPLIES IF A;-)- B YES ® NO ❑ I EnergyPro 4.4 by EnegySoft User Number. 3665 Job Number. Pace: 13 of 31 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Larsen Residence 4/22/2009 SYSTEM NAME FLOOR AREA HVAC -#1 1,710 Number of Systems 1 Heating System Output per System 86,000 Total Output (Stub) 86,000 Output (Btuh/sgft) 50.3 Cooling System Output per System 58,500 Total Output (Stuh) 58,500 Total Output (Tons) 4.9 Total Output (Stuh/sgft) 34.2 Total Output (sgft/ron) 350.8 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.17 Airflow (cfm/Ton) 410.3 Outside Air (°%) 6.4 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions 26.0 OF 0 Outside 128 cfm 78.5 OF 11.0 / 77.6 OF I Outside Air 128 cfm 73.5/60.1 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAR COIL HTG. PEAK CFM I Sensible Lat—t CFM I Sensible 41689 5:895 46,890 PSA2BD / PGCIRA (5 Ton)14 SEER 49,411 0 86,000 Total Adjusted System Output 49,411 0 ,000 86 (Adjusted for Peak Deslgn Conditions) TIME OF SYSTEM PEAK Aug -2 pm] F Jan 12 am 75.2 OF ® 115.60F Heating Coil Supply Fan 2000 cfm 115.6OF -)OSupploir Ducts 114.1OF ROOMS 80.0 OF h Return Air Ducts `S 75.9/61.5 OF ® 52.7/51.5 OF Cooling Coil Supply Fan 2000 cfm 52.7 / 51.5 OF -� Supply Air Ducts 54.1 / 52.2 OF 48.5°% R.H. ROOMS 72.0 / 59.6 OF h Return Air Ducts `i EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Paue:14 of 31 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Larsen Residence 4/22/2009 SYSTEM NAME FLOOR AREA HVAC -#2A &2B 4,249 Number of Systems 2 Heating System I Sensible Output per System 86,000 Total Output (Btuh) 172,000 Output (Stuh/sgft) 40.5 Cooling System Output per System 58,500 Total Output (Btuh) 117,000 Total Output (Tons) 9.8 Total Output (Stuh/sgft) 27.5 Total Output (sgft/Ton) 435.8 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sgft) 0.94 Airflow (cfm/Ton) 410.3 Outside Air (%) 8.0 Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions 26.0 of 311 Outside Air —� 319 cfm 78.1 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent I I CFM I Sensible 109,4051 13,110 PSA28D / PGCIRA (5 Ton) 14 SEER 100,055 0 172,000 Total Adjusted System Output100,055 0 172,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 pm I I Jan 12 am 73.9 OF ® 114.30F Heating Coil Supply Fan 4000 cfm 114.30F -� Supply Air Ducts 112.4 OF ROOMS 80.0 OF h Retum Air Ducts 4 111.0 / 77.6 OF 76.9 / 62.3 of 53.4 / 52.3 of Outside Air 319 cfin Cooling Coil Supply Fan 4000 cfm 74.0/60.7 of 53.4 / 52.3 of Supply Air Ducts 55.4 / 53.1 of 49.8% R.H. ROOMS 72.0 / 60.0 of h Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Paae:15 of 31 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY J PROJECT NAME I DATE The Larsen Residence 4/22/2009 SYSTEM NAME FLOOR AREA HVAC -#3 758 me: mor-g21tJP rw:r S SYSTEM I Aen Number of Systems 1 Heating System Output per System 86,000 Total Output (Stuh) 86,000 Output (Stuh/sgft) 113.5 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 77.2 Total Output (sgft/Ton) 155.5 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 2.64 Airflow (cfmrron) 410.3 Outside Air (%) 2.8 Outside Air (cfm/sclM 0.07 Note: values above given at ARI conditions 26.0 of ma Outside —y 57 cfm 79.1 of 11.0 / 77.6 of )� Outside Air 57 cfm 72.8/59.0 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM I Sensible Latent I CFM I Sensible 21,5961 3, 203 29,083 PSA2BD / PGC1 RA (5 Ton) 14 SEER 48,049 0 86,000 Total Adjusted System OutputA8 pg9 0 86,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 wn Jan 12 am 77.50F N 117.90F Heating Coil Supply Fan 2000 cfm 117.90F -� Supply Air Ducts 117.0 of ROOMS 80.0 of w% Retum Air Ducts `S 73.9 / 59.7 of 51.3 / 50.2 of 51.3/50 , 2 OF O Supply Air Ducts Cooling Coil Supply Fan 52.1 / 50.5 OF 2000 cfm 45.4% 2.1-1. ROOMS 72.0 / 58.7 of h Retum Air Ducts `i I EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 16 of 31 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Larsen Residence 4/22/2009 SYSTEM NAME FLOOR AREA HVAC -#4 520 IFENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 36,000 Total Output (Stub) 36,000 Output (Stuh/sgft) 69.2 Cooling System Output per System 24,400 Total Output (Stuh) 24,400 Total Output (Tons) 2.0 Total Output (Btuhlsgft) 46.9 Total Output (sgft/Ton) 255.7 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.54 Airflow (cfm/Ton) 393.4 Outside Air (%) 4.9 Outside Air (cfm/sgft) 0.08 Nota: values above given at ARI conditions 26.0 of 0 Outside 39 cfm 78.6 of 11.0 / 77.6 of 0 Outside 39 cfm 73.2/59.5 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAKCOIL HTG. PEAK CFM ISensiblel nt CFM I Sensible 13 935 2 416 17,234 31) / PGCIRA (2 Ton)14 SEER 20,313 0 36,000 —71 Total Adjusted System Output20,313 0 36,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 76.10F �I ® 118.30F Heating Coil Supply Fan 800 cfrn 118.3 of -� Supply Air Ducts 117.0 of ROOMS 80.0 of �% Retum Air Ducts 'I 75.1/60.60F ® 51.2/50.10F Cooling Coil Supply Fan 800 cfm 51.2 / 50.1 OF -� Supply Air Ducts 52.5 / 50.6 of 46.4% R.H. ROOMS 72.0 / 59.0 of h Return Air Ducts `S EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 17 of 31 ROOM LOAD SUMMARY PROJECT NAME The Larsen Residence DATE 4/22/2009 SYSTEM NAME HVAC -#1 FLOOR AREA 1,710 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Z NE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 Master Suite 1 1,594 30,289 2,956 1,594 30,289 2,956 923 33,529 PAGE TOTAL 1 1,594 30,286 2,956 923 33,529 TOTAL 1 1,594 30,289 2,956 923 33,529 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 16 of 31 ROOM LOAD SUMMARY PROJECT NAME The Larsen Residence DATE 4/22/2009 SYSTEM NAME HVAC -#2A &2B FLOOR AREA 4 249 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mutt CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #2 Great Room/Dining/Theater 1 4,528 80,213 6,157 4,528 80,213 6,157 2,568 88,583 PAGE TOTAL 1 4,528 80,213 3,157 2,568 88,583 TOTAL 1 4,528 80,213 3,157 2,568 88,583 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 19 of 31 ROOM LOAD SUMMARY PROJECT NAME The Larsen Residence DATE 4/22/2009 SYSTEM NAME HVAC -#3 FLOOR.AREA 758 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Muit. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #3 Guest Suite 1 & 2 1 753 15,973 1,756 753 15,973 1,756 555 21,841 PAGE TOTAL 1 753 15,973 1,758 555 21,841 TOTAL 1 753 16,973 1,758 555 21,841 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 20 of 31 ROOM LOAD SUMMARY PROJECT NAME The Larsen Residence DATE 4/22/2009 SYSTEM NAME HVAC44 FLOOR AREA 520 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mu@. CFM SENSIBLE LATENT CFM ISENS113LE LATENT CFM I SENSIBLE ZONE 94 Guest Casita 1 493 10,244 1,456 493 10,244 1,456 323 12,705 PAGE TOTAL 1 493 10,244 1,456 323 12,705 TOTAL 1 4931 10,2441 1,456 323 12,705 EnergyPro 4.4 by ErrergySoft User Number. 3665 ,lob Number. Page: 21 of 31 ROOM HEATING PEAK LOADS Project Title Date The Larsen Residence 4/22/2009 Room Information Desian Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 1,710 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 80 OF Conduction Area U -Value AT of Btu/hr R-38 Roof Skytiaht Skylight R-21 Wall Loewen Dial CIr (Csmi) (131) Loewen QbI Clr 3 Loewen D I CIr Loewen ON Clr Fxd R5 Cir jFxd)7 R-21 Wall Loewen 0bl Cit Fxd 1-1 Loewen Dbl Or Csmt 01 Loew n Dbl Clr Fxd 1-2 Loewen DhI Cir (Fxd) (PI) R-21 Wall R-21 Mill Loewen Dbi Ir F 1 R-21 Wail R-21 Wall R-21 Wall Loewen Dbl C r sm Al Loewen D 1 Or 1 R-21 VAM11 Slab -On -Grade Items shown with an asterisk (7 denote conduction through an interior surface to another room. Infiltration: r 1.00 1 x Lisa x 1 710 x 10.00 x 0.392 / 6� x `Schedule Air Sensible Area Ce111ngelght ACH Fraction Page Total: 5a AT 2,265 1,270 1,270 942 1,332 40 40 40 4 40 133 338 778 338 238 317 505 864 764 1,346 SIR 797 729 2,644 857 7.667 27113 = s a1s TOTAL HOURLY HEAT LOSS FOR ROOM 33,529 F.nergyPro 4.4 by EnargySoft User Number. 3665 Job Number. Page: 22 of 31 ROOM HEATING PEAK LOADS I Project Tide The Larsen Residence Date 4/22/2009 Room information Desian Conditions Room Name Great Time of Peak Jan 12 am Floor Area 4,249 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 80oF Loewen nhl Cir (SwngDr) Conduction R-38 Roof Skylight R-21 Wall Loewen Dbl Cir Csmt A2 Loewen nhl Cir (SwngDr) (109A) R-21 Wall Loewen Dbl CirFx Loewen Dbi Cir Fxd M5 R-21 Wall Loewen DI OrS 1 Solid Wood r)nnr R-21 Wall Loewen Dbl Clr Fxd G1 R-21 Wall en Dbl Cir m Loewen Dbl Clr Fxd M1 Loewen DbI Cir (Fxco (Cl) R-21 Wall R-21 Wall Loewen Ir D 12 Loewen DbI Cir (Fxd) (II) Loewen Dbl Cir Csmt E2 R-21 Wall Slab -On -Grade Area U Value AT of Btu/hr Items shown with an asterisk (7 denote conduction through an Interior surface to another room. Page Total: Infiltration: 1.00 1 x 1.osa x alas x 14.5 x 0.270 160] x cheduie Air Sensible Area Coiling Height ACH AT Fraction 72 641 15 942 TOTAL HOURLY HEAT LOSS FOR ROOM 88,583 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 23 of 31 ROOM HEATING PEAK LOADS Project Title The Larsen Residence Data 14/22/2009 Room Information Desian Conditions Room Name Guest suite 1 & 2 Time of Peak Jan 12 am Floor Area 758 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 80 OF 54 Conduction Area 758.0 492.0 394.5 10.0 10.0 10.0 359.0 25.0 52.5 88.0 310.5 48.0 6.5 p1jimeter =197.5 U -Value 0.0250 0.0690 0.0690 0.5000 0.5000 0.5000 0.0690 0.4500 0,5000 0.0690 0.0690 0.4500 0690 0.7300 Items shown with an asterisk (1) denote conduction through an interior surface to another room. Infiltration: r 1.00 x 1.064 x 758 x 10.50 x 0.373 heft a Air Sensible Area Ceiling Height ACH Fraction x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x A11 of = = = = = = - = = = = = = = = = = = = = o = = = = = = = = = = - = = = = Btu/hr 54 1,023 54 1,833 54 1,470 54 270 54 270 54 270 54 1,338 54 608 54 1,418 54 328 54= .54 1,166 54 61 54 7,785 Page Total: I 18.9971 16 0] x AT TOTAL HOURLY HEAT LOSS FOR ROOM 21,841 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 24 of 31 ROOM HEATING PEAK LOADS Project Title Date The Larsen Residence 14/22/2009 Room Information Desian Conditions Room Name Guest casite Time of Peak Jan 12 am Floor Area 520 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 80 OF Conduction Area U -Value AT of Btuthr 520.0 x x X X X X X x X X X x X X X X X x X X X X X X X X X X X X X X X X X X X X X 0.0250 x x x x x X X X X X X X x X X x X X x X X X X x X X x X x x x X X x X X X X X 233.0 0.0690 6.0 0.5000 1.5 0.5000 1.5 0.5000 304.5 0.0690 10.0 0.5000 10.0 0.5000 236.5 0,0690 45.5 0.0690 48.0 0.4500 134.0 0.0690 20 0.4500 22.0 0.0690 wdineter=1 01A 0.7300 Items shown with an asterisk (*)*rdenote conduction through an interior surface to another room. Infiltration: II 1.00 x 1.084 x 520 x 11.00 x 0.356 / 6] x hedule AlrSenalble Area Ce111ngHelght ACH Fraction Page Total: AT 10 754 = 1 951 TOTAL HOURLY HEAT LOSS FOR ROOM 12,705 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page:25 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title The Larsen Residence Orientation Date 14/22/2009 Room Information Desi n Conditions Room Name: Master Suite Outdoor Dry Bulb Temperature: 1120E Floor Area: 1,710 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72 *F Outdoor Daily Range: 34OF Items shown with an asterisk (7 denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Dtfferenoe (CLTD) Fenestration Btu/hr Orientation Orientation Area x X X X X X X X X x x x U -Factor X X X X X X X X x x x x CLTD 1 = = = = = = = = = = E 1,678.0 0.0173 56.0 E 252.7 0.0690 33.0 SE 304.2 0.0690 31.0 S 85.0 0.0690 26.0 S 135.6 0.0690 31.0 2,960 205.01 0.0690 33.0 (NW) 361.3 0.0690 30.2 (N) 213.8 0.0690 23.0 NE 230.0 0.0690 29.0 1.5X 74.6= 112 E 0.0 34.9 1.5 74.6 112 E 0.0X 34.9+ Items shown with an asterisk (7 denote conduction through an interior surface to another room. Page Total 1. Cooling Load Temperature Dtfferenoe (CLTD) Fenestration Btu/hr Orientation Shaded Area x X x X X x GLF + + + + + + Unshaded Area x X x X X x GLF = = = = = Btu/hr S 0.0 58.5 16.0 161.4 2,582 S 0.0x 58.5+ 16.0X 161.4= 2,582 E 9.1 28.3 45.7 59.2 2,960 E 0.0x 34.9+ 1.5X 74.6= 112 E 0.0x 34.9+ 1.5X 74.6= 112 E 0.0x 34.9+ 1.5X 74.6= 112 E 0.0 34.9 1.5 74.6 112 E 0.0X 34.9+ 1.5x 74.6= 112 SE 0.0 34.9 12.5 50.3 629 SE 0.0 28.3 32.0 40.3 1,288 Page Total 10 602 Internal Gain Btu/hr Occu ants 4 Oawpants X 230 Btuh/occ. _ 920 E ui ment FDwelling Units X 11,600 BtUh 1 600 Infiltration: 1.064 X 0.92 X 1 8.35 X = 4 236 AlrSensible CFM ELA OT OTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30 289 Latent Gain BtuRtr Occu nts Occupants X 200 BtUh/OCC. = 800 Infiltration: 4,77 x 0.92 x 108.35 x 0.00454 = 2156 Air Latent CFM ELA 6,w [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2 956 EnergyPro 4.4 by Energy8aft User Number. 3666 Job Number. Page: 26 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Tide The Larsen Residence Btuthr Date 4/22/2009 Room Information Desi n Conditions Room Name: Master Suite Outdoor Dry Bulb Temperature: 1120F Floor Area: 1,710 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 34OF uurraces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Goofing Load Temperature Difference (CLTD) Fenestration Page Total Orientation Btuthr x x x x x x x x x x x x------------------- X X X x X X x X X X x x x x x x x x x x x x x + + + + + + + + + + + = = = = = = = x X X x X x x X x X x GLF = = = = = = = = = Stu/hr SE 0.0 34.9 12.5 50.3 629 SE 0.0 34.9 8.8 50.3 443 S 0.0 34.9 32.0 50.3 1,609 N 0.0 31.5 20.0 50.5 1,009 N 0.0 28.3 30.0 28.3 849 N 0.0 28.3 108.8 28.3 3,079 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Goofing Load Temperature Difference (CLTD) Fenestration Page Total Orientation Btuthr Shaded Area X X X x X X x X X X x GLF + + + + + + + + + + + Unshaded Area x X X x X x x X x X x GLF = = = = = = = = = Stu/hr SE 0.0 34.9 12.5 50.3 629 SE 0.0 34.9 8.8 50.3 443 S 0.0 34.9 32.0 50.3 1,609 N 0.0 31.5 20.0 50.5 1,009 N 0.0 28.3 30.0 28.3 849 N 0.0 28.3 108.8 28.3 3,079 Page Total 7 617 Internal Gain Btuthr loccupants 4 Occupants X 230 Btuh/occ. = EDwelling 920 E ui ment Units X 1,6001 Btuh 1 1,6001 Infiltration: 1.064 X 0 92 X 1 8.35 x = 4238 Air Sensible CFM ELA AT [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 80 2159 Latent Gain ger Occupar Occupants X 200 Btuh/occ. Boo Infiltration: 4 77 x 0.92 x 108.35 x 0.00454 = 2 156 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 27956 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 27 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title The Larsen Residence Date 4/22/2009 Room Information Desion Conditions Room Name: Great Room/Diningrrheater Outdoor Dry Bulb Temperature: 1120F Floor Area: 4,249 sf Outdoor Web Bulb Temperature: 780E Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 34OF bITFIr-T;-P Wall Wall Orientation Area x x x x X X x x X x X X U -Factor X X X X X X x x X x X X CLTD 1 = = = = = = = = = E 4,222.0 0.0173 56.0 E 556.0 0.0690 33.0 SE 51.0 0.0690 31.0 S 1,019.5 0.0690 26.0 S 24.0 0.5000 26.0 S 138.0 0.0690 31.0 (W) 1,094.7 0.0690 33.0 (NW) 140.0 0.0690 30.2 N 594.0 0.0690 23.0 31.5 0.0 31.6 9,448 S 17.5 34.9 30.5 50.3 2,143 4.5X 34.9+ 19.5X 74.6= Pa a Total Items shown with an asterisk (q denote conduction through an interior surface to another mom. if 1. Cooling Load Temperature Dlfierenos (CLTD) Fenestration Skylight CsmntWdw A2 Swn GlsDr 009A FxdWdw G3 FxdWdw M5 Sld GlsDr 127A FxdWdw G1 FxdWdw H1 Swn GIsDr 141A FxdWdw H2 Btu/hr Orientation Btu/hr Shaded Area x x X X X X X X X X GLF + + + + + + + + + + Unshaded Area X X X x X x X X X X GLF = = = = = = = = = Btu/hr S 0.0 58.5 27.0 161.4 4,358 E 9.0 28.3 21.0 59.2 1,497 0.0 21.6 48.0 41.8 2,007 SE 17.5 34.9 30.5 50.3 2,143 SE 0.0 34.9 6.0 50.3 302 S 300.0 31.5 0.0 31.6 9,448 S 17.5 34.9 30.5 50.3 2,143 4.5X 34.9+ 19.5X 74.6= 1,612 4.5 21.6 19.5 41.8 912 4.5 34.9 19.5 74.6 1,612 Page Total 2s o35 Internal Gain Btu/hr Occupants 4 Otxupants X 230 Btuh/oCC. EDwelling 920 _ E ui ment Units X 1,600 Btuh 1 600 Infiltration: 1064 x 0.92 X 69.22 X = 10 525 AirSensibte CFM ELA &T OTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 80213 Latent Gain Btu/hr lowupants 0 occupants x 200 Btuh/occ. = 800 Infiltration: 4,77 x 0.92 x 269.22 x 0.00454 = 5 357 Air Latent CFM ELA pw IT-OTAL HOURLY LATENT HEAT GAIN FOR ROOM 77 s,157 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number. Page: 28 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Larsen Residence 14/22/2009 Room Information Desion Conditions Room Name: Great Room/Dining/Theater Outdoor Dry Bulb Temperature: 112 Floor Area: 4,249 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72OFOutdoor Daily Range: 34OF surfaces Orientation Area U -Factor CLTD 1 NE 351.0 X 0.0690 X 29.0 = X X = X X X X X X x x x x = x x = x x x x = x x X I x = Pa a Total Items shown with an asterisk (q denote conduction through an interior surface to another room. g 1. Cooling Load Temperature Difference (CLTD) Fenestration CsmntWdw E3 FxdWdw Mi CsmntWdw B1 FxdWdw(Cl) Sid GIsDr 1278 FxdVVdw 1 CsmntWdw E2 Sld GISDr 123A CsmntWdw A3 Swn GIsDr 103A Orientation Btu/hr Shaded Area X X X X X X X X X X GLF + + + + + + + + + + Unshaded Area x x X X X X X X X X GLF = = = = = = = = = = Btu/hr 80 213 18.1 28.3 90.7 59.2 5,878 5 357 0.0 34.9 6.0 74.6 448 0.0 28.3 25.0 59.2 1,479 0.0 34.9 18.0 74.6 1,344 N 0.0X 31.5+ 200.0X 31.5= 6,299 N 0.0 34.9 37.5 34.9 1,307 N 0.0 28.3 108.8 28.3 3,079 NE 0.0 31.5 120.0 50.5 6,056 NE 0.0 28.3 30.0 45. 1 351 NE 0.0 21.6 48.0 32.6 1,562 Page Total 28 Sot Internal Gain Btu/hr Occupants 4 Occupants X 230 Btuh/ocC. _ EDwelling 920 E ui ment Units X 1,600 Btuh 1 600 Infiltration: 1.064 X 0 92 X 289 22 X = 10 5 5 Air Sensible CFM ELA OT OTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 80 213 Latent Gain Btu/hr Accu nts ® Occupants X 200 Btuh/occ. = 800 Infiltration: 4,77 x 0.92 x 269.22 x 0.00454 = 5 357 AlrLatent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6,157 EnergyPro 4.4 by Energy3oft User Number: 3665 Job Number: Page: 29 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title The Larsen Residence Area Date 4/22/2009 Room Information Desian Conditions Room Name: Guest Suite 1 & 2 Outdoor Dry Bulb Temperature: 1120F Floor Area: 758 sf Outdoor Web Bulb Temperature: 78OF Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 34OF surraces R-21 R-21 Wall Orientation Area X X X X X X x X X X X X U -Factor X X X X X X X x X X X X CLTD 1 = = = = = = = = = = = E 758.0 0.0173 56.0 E 492.0 0.0690 33.0 S 394.5 0.0690 26.0 34.9 359.0 0.0690 33.0 S 88.0 0.0690 30.2 N 310.5 0.0690 23.0 (NE) 16.5 0.0690 29.0 0.0x 34.9+ 52.5X 74.6= 3,919 N 0.0X 21.6+ 48.0X 21.6= 1,038 Pa a Total Items shown with an asterisk (') denote conduction through an interior surface to another room. g 1. Cooling Load Temperature Difference (CLTD) Fenestration Btulhr 734 1,120 708 817 184 493 33 4 089 Orientation Btuthr Shaded Area x X x x X X X X X GLF + + + + + + + + + Unshaded Area x X X X X X X X X GLF = = = = = = Btu/hr S 0.0 34.9 10.0 35.0 350 S 0.0 34.9 10.0 35.0 350 S 0.0 34.9 10.0 35.0 350 0.0 28.3 25.0 59.2 1,479 0.0x 34.9+ 52.5X 74.6= 3,919 N 0.0X 21.6+ 48.0X 21.6= 1,038 Page Total 7,aas Internal Gain Btuthr loccupants 4 Occupants X 230 Btuh/occ. = EDwelling 920 E ui ment Units X 1 600 Btuh 1 1,6001 Infiltration: 1.084 X 0.92 X 48 0 X = 1 878 Air Sensible CFM EIA DT OTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15 973 Latent Gain Btu/hr pants ® Occupants x 200 Btuh/occ. = 800 Infiltration: 4 77 x 0.92 X 48.03 x 0.00454 = 956 Air Latent CFM SLA pw OTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,756 EnergyPro 4.4 by EnergySa User Number. 3665 Job Number: Page: 30 of 31 RESIDENTIAL ROOM COOLING LOAD SUMMARY I Project Title The Larsen Residence Area Data 14/22/2009 Room Information Desian Conditions Room Name: Guest Casita Outdoor Dry Bulb Temperature: 1120E Floor Area: 620 sf Outdoor Web Bulb Temperature: 780E Indoor Dry Bulb Temperature: 72 of Outdoor Daily Range: 34OF surraces Wall Orientation Area X X X X X X X X X X X X U -Factor X X X X X X x X X X X X CLTD 1 = = = = = = = = I E 520.0 0.0173 56.0 E 233.0 0.0690 33.0 S 304.5 0.0690 26.0 34.9+ 236.5 0.0690 33.0 N 45.5 0.0690 30.2 (N) 134.0 0.0690 23.0 (NE) 22.0 0.0690 29.0 S 0.0 34.9 10.0 35.0 350 0.0 28.3 48.0 45.0 2,16 N 0.0X 21.6+ 20.0X 21.6= 432 Pa TM Items shown with an asterisk (•) denote conduction through an Interior surface to another room. ge a 1. Goofing Load Temperature Difference (CLTD) Fenestration Btu/hr Orientation Btu/hr Shaded Area x X X x X- X X X GLF + + + + + + + + Unshaded Area X X X X X X X X GLF = = = = = = = Btu/hr E 0.0 34.9 6.0 74.6 448 E 0.0x 34.9+ 1.5x 74.6= 112 E 0.0x 34.9+ 1.5x 74.6= 112 S 0.0 34.9 10.0 35.0 350 S 0.0 34.9 10.0 35.0 350 0.0 28.3 48.0 45.0 2,16 N 0.0X 21.6+ 20.0X 21.6= 432 Page Total 3 965 Internal Gain Btu/hr 10ccupants 4 Occupants X 230 BtuhloCC. _ 920 E ui ment Dwelling Units X 1 600 Btuh 1 600 Infiltration: X 0 92 X 32.5 X Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM10 244 Latent Gain Btu/hr Occu nts ® Occupants x 200 Btuh/OCC. 800 Infiltration: 4,77 x 0.92 x 32.95 x 0.00454 = 656 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,456 En.W.4.4 by EnergySoft User Number: 3665 Job Number. Page: 31 of 31 PICTURE/DIRECT SET WINDOW PERFORMANCE RATINGS ` tCSA A440-00 - CANADA Product Type Unit Size Air Leakage Water Leakage Structural Forced Entry Picture 94 1/2• x 82 11/16° Fixed 87 C3 3/4' (19 mm) (2400 mm x 2100 mm) 0.038 m'/hr/m ® 700 Pa ® 3000 Pa Not Tested (Non Clad) 8 -Dec -03 ® 75 Pa (14.63 psf) (62.65 psf) Picture 78 3/4" x 78 3/4' Fixed B7 CS 3/4' 119 mm) (2000 mm x 2000 mm) 0.06 m'/hr/m ® 700 Pa ® 5000 Pa Not Tested (Metal Clad Direct Set) ® 75 Pa (14.63,psf) (105.0 psf) Picture 94 1/2° x 59.1/16° Fixed 87 < C4 1 3/8' (35 mm)',- (2400 mm x 1500 mm) 0.64 ml/hr/m__ @ 700 Pa @ 4006 Pa Not Tested.." P (Non Clad) T 4^ '.2 -Apr -04 @ 75 Pa (14.63'psf) (83.54 psf) ._ 4 Picture 94 1/2' x 82 11/16• Fixed 87 C4 1 3/8' (35 mm) (2400 mm x 2100 mm) 0.052 m'/hr/m ® 700 Pa ® 4000 Pa Not Tested (Metal Clad) 8 -Dec -03 ® 75 Pa (14.63 PA (83.54 pso Product Type Unit Size Air Leakage Water Leakage Structural Forced Entry t• Picture 94 1/2" x 82 11/16° Pass F•C90 F -CSS (Non Clad) (2400 mm x 2100 mm) 0.007 ft'/m/ft' ® 650 Pa ® 3960 Pa Not Tested 10 -Dec -03 ® 75 Pa (13.5 pso (82.5 pso, Picture 78 3/4° x 78 3/4" Pass F-HC80 F-HC70 ` (Metal Clad) (2000 mm x 2000 mm) 0.002 ft'/m/ft' ® 580 Pa ® 5040 Pa Not Tested 10 -Dec -03 ® 300 Pa (12 psf) (105 pso f Picture 94 1/2' x 59 1/16" Pass F -C60 F -C60 t. 1 3/8' 135 mm) (2400 mm x 1500 mm) 0 ft'/m/ft' ® 720 Pa ®4320 Pa Not Tested (Non Clad) 2 -Apr -04 @ 75 Pa (15 psfl (90.0 pso Picture W 1/2' x'8211/16° Pass _ 0-C90 _ F -C60 1 3/8' (35 mm) ,94 (2400 mm x,21 00 mm) 0.0055 ft'/m/ft' : ®.650 Pa ® 4320 Pa Not Tested N (Metal Clad) - 10 -Dec -03 - ® 75 Pa '-(13.5 psf) * (90.0 psfl , e.. - 3 _ o " 'y ••NON CLAD Ln Product Type Glazing Type Spacer Gap Fill 1 Gap Fill,2 U -Factor Res SHGC (max) VT (max) � Picture Double Clear Standard) Air f] 0.50 0.67 0.71 S 3/4' (19 mm) DoubleClear Standard Argon 0.47 0.67 0.71 HP1 Standard Air 0.33 0.36 0.63 HP1 Standard Argon 0.29 0.36 0.63 --j Standard Argon Air 0.24 0.33 , 0.57 HP3 Standard Air Air 0.21 0.31 0.50 CL HP3 Standard Argon Argon 0.18 0.31 0.50 HP1 Thermal Edge Argon 0.28 0.36 0.63 HP2 Thermal Edge Argon Air 0.23 0.33 0.57 HP3 Thermal Edge Argon Argon 0.17 0.31 0.50 Picture Double Clear Standard Air 0.47 0.66 0.70 t E24 1 3/8• (35 mm) Double Clear- Standard Argon 0.44 0.66 0.70 ._ HP1 Standard Air 0.32 0.35 0.61 HP1 Standard Argon' 0:28:., 0.35 ' -0.61 HP1 Thermal Edge Air ` 0.31 0.35 0.61 HP1, Thermal Edge > Argon, - 0.28 ' 0.354 0.61 =0.61 Double -Sun 140 Standard Air. -d6' Air 0.32 _ .0.22-7, 0.34'- ' Double -Sun 140 Standard Arg Argon - 0.28`" 0.21 0.34 'a r .. i• • � th .. - .. f• 4 r \ f CASEMENT WINDOW PERFORMANCE RATINGS Product Type Glazing Type Spacer Gap Fill 1 Gap Fill 2 U -Factor Res SHGC (max) VT (max) Casement (Double Clear Stands - (Air 0.52 035 • Double Clear Standard Argon 0.43 0.52 0.55 Q HP1 Standard Air 0.33 0.28 0.48 ' HPI Standard Argon 0.30 0.28 0.48 HP2 Standard Air 0.27 0.26 0.44 HP2 Standard Argon 0.25 0.26 0.44 HP3 Standard Air 0.23 0.24 0.38 - HP3 Standard Argon 0.21 0.24 0.38 HP1 Thermal Edge Air 0:33 0.28 0.48 HPI Thermal Edge Argon 0.30 0.28 0.48 HP2 Thermal Edge Air 0.26 0.26 0.44 HP2 Thermal Edge Argon 0.24 0.26 0.44 HP3 HP3 Thermal Edge Air Thermal Edge Argon 0.22 0.20 0,24 0.24 0.38 0.38 4 �� Triple Clear Standard Air Air 0.33 0.47 0.50 - Triple Clear Standard Argon Argon 0.31 0.47 0.50 Double Sun 140 Standard Air 0.34 0.18 0.27 Double Sun 140 Standard Argon 0.31 0.17 0.27 Triple Sun 140 Standard Air Air 0.27 0.16 0.24 Triple Sun 140 Standard Argon Argon 0.26 0.16 0.24` II; Triple Sun 140 Dual Low E Standard Air Air 0.24 0.14 0.21 Triple Sun 140 Dual Low E Standard Argon Argon 0.21 0.14 0.21 Push Out Casement Double Clear Standard Air 0.45 0.52 0.55 Double Clear Standard Argon 0.44 0.52 ( 0.55 HP1 Standard Air 0.34 0.28 0.48 HP1 Standard Argon 0.31 0.28 0.48 tyJ HP2 Standard Air Air 0.28 0.26 6.44 HP2 Standard Argon Argon 0.26 0.26 0.44 HP3 Standard b Air Air 0.24 0.24 0.38 HP3 Standard 3 Argon Argon 0.22 0.24 0.38 HPI Thermal Edge Air 0.33 0.28 0.48 HPI Thermal Ede Argon 0.30 0.28 0.48 HP2 Thermal Edge Air - Air 0.27 0.26 0.44 HP2 Thermal Edge Argon Argon 0.25 0.26 0.44 HP3 Thermal Edge Air Air 0.23 0.24 9.38 HP3 Thermal Edge Argon: Argon 0.21 0.24- 6.38 Triple Clear - Standard Air Air 0.33 0.47 0.50 _ Triple Clear Standard Argon Argon 0.32 0.47 0.50 1 m Double Sun 140 Standard Air 0.34 0.18 0.27 3 Double Sun 140 Standard Argon 0.31 0.17 0.27 _0 Triple Sun 140 -Standard :. Air Air 0.28.. 0.16 0.24 Triple Sun 140 Standard Argon Argon 0.26 0.16 0.24 .. Triple Sun 140 Dual Low E Air Air 0.24 0.14 0.21 c _ Triple Sun 140 Dual Low E _Standard Standard Argon Argon 0.22' 0.14 0.21 to w Fixed Casement ' Double Clear Standard'-` Air �+ 0.46 0.61• = 0.641 23•Sep-03 - = a --Double Clear' `Standard •,- _ Argon '_ 0.44 - 0.61- _' 0.64 m HP1 Standard - Air 0.32 0.33 0.56 V Hl HPI "Standard. rThermal Edge Argon Air 029_ ' - 0.32• �' 1. 0.32 0.33 0.56 ' • 0.56 HP1.-. - .Thermal Edge Argon r« 0.28 0.32 0.56 r_ Double Sun 140 Standard Air 0.33 0.20 0.31 Double Sun 140 Standard Argon 0.29 0.20 0.31 :B49 - v c, � y t O � l \ f 0 0 0 m V LL 01= C J28 r . WOOD PATIO & FRENCH PATIO DOOR PERFORMANCE RATINGS ' CSA A440-00 D• Product Type Unit Size Air Leakage WatecLeakage Structural Forced Entry Standard Sliding 10 7/8" x 82 11/16' A3 83 C3 Patio Door (1800 mm x 2100 mm) 0.699 m'/hr/m ® 300 Pa ® 2500 Pa F10 (Metal Clad) ® 75 Pa (6.26 psf) (52.2 psf) Enhanced DP 70 7/8' x 81 11/16' A2 84 C3 Sliding Patio Door (1800 mm x 2100 mm) 1.07 m'/hr/m ® 400 Pa ® 2500 Pa 1`10 (Metal Clad) @ 75 Pa (8.35 psk (52.2 psf) Standard Sliding 94 1/2' x 106 5/16' A2 B3 C3 French Patio Door (2400 mm x 2700 mm) 1.65 m'/hr/m ® 300 Pa ® 2500 Pa ^ (Metal Clad) ® 75 Pa (6.26 psf) (52.2 psf) Enhanced DP Sliding 94 1/2' x 82 11/16" A2 B4 C3 French Patio Door.,_ (2400 mm x 2100 mm) 1.28m'/hr/m ® 400 Pa ® 2500 Pa (Non Clad) ® 75 Pa (8.35 psf) (52.2 psf) `Enhanced DP Sliding 94 1/2' x8211/16' A2 84 C3 French Patio Door , (2400 mm x 2100 mm) 1.62 m'/hr/m - ®400 Pa ®2500 Pa .. ' • (Metal Clad) @ 75 Pa ? (8.35 psf) (52.2 psi) . , Product Type Unit Size Air Leakage Water Leakage Structural Forced Entry Standard Sliding 94 1/2" x BS 3/8' Pass SGD-C40 SGD-C45 Patio Door (Metal Clad) (2400 mm x 2169 mm) 0.17 ft'/m/ft' ® 75 Pa ® 6.00 psf (290 Pa) ® 67.5 psf (3240 Pa) F10 Enhanced DP 70 7/8' x 82 11/16' Pass SGD-1170 SGD-R70 - Sliding Patio Door (1800 mm x 2100 mm) 0.18 ft'/m/ft' ® 10.5 psf ® 105 psf (Metal Clad) G 75 Pa (510 Pa) (5040 Pa) Standard Sliding 94 112' x 106 5/16' Pass SGD-1145 SGD-R40 French Patio Door (Metal Clad) (2400 mm z 2700 mm) 0.15 fN/m/ft' ® 75 Pa @ 6.75 psf (330 Pa) ® 60.0 psf (2880 Pa) Enhanced DP 94 1/2' x 8211/16' Pass SGD-C70 SGD-C65 '• French Sliding Patio (2400 mm x 2100 mm) 0.17 ft/m/ft' 0 10.5 psf U 97.5 psf Door (Non Clad) ® 75 Pa - (510 Pa) (4680 Pa) Enhanced DP, = 94 1/2' x 82 11/16' - Pass SGD-C70 SGD-C65 .',French Sliding Patio .' (2400 mm x 2100 mm) ;.0.19 fN/m/k' ;.. d,; ,® 10.5 psf ®97.5 psf' • Door (Metal Clad) -' ®75 Pa " (510 Pal (4680 Pa) . - r • r, Product Type Glazing Type Spacer Gap .Fill •1 Gap Fill 2 U -Factor Res SHGC (max) VT (max) Sliding Patio Door DoubleClearStandard Air Q 0.48 0.59 0.61 ' Double Clear Standard Argon 0.46 0.59 0.61 HP1 Standard Air 0.34 0.32 0.54 HPI Standard Argon 0.31 0.32 0.54 HP2 Standard Argon Air 0.26 0.29 0.49 HP3 Standard Air Air 0.23 0,27 0.43 x HP3 Standard Argon Argon 0.21 0.27 0.43 HP1 Thermal Edge Argon 0.30 0.32 0.54 HP2 Thermal Edge Argon Air 0.25 0.29 0.49 HP3 Thermal Edge Argon Argon 0.20 0.27 0.43 French Sliding Double Clear Standard Air 0.46 0.50 0.50 _ -Patio Door - Double Clear Standard Argon - - 0.44 0.50 0.50 - HP1 Standard Air 0.34 0.28 0.45 HP1 Standard Argon 0.31 0.28 0.45 R« HP2 Standard' Argon' Air 0.27 0.25' 0.41. HP3 Standard Air , -. _ Air 0.25 0.23. 0.36 3 3 . HP3 Standard Argon Argon 0.23 0.23- 0.36 � HP1 Thermal Edge.;- Argon: = 0.31 .. 0.28 . 0.45 x = ' • -` HP2 ,- _ ` Thermal Edge - Argon ; Air - 0.26 _ 0.25 •- 0.41 ' " ' HP3 Thermal Edge Argon- Argon 0.22 0.23 0:36 SWINGING,TERRACE & FRENCH TERRACE DOOR PERFORMANCE RATINGS I l'f Product Type Glazing Type Spacer Gap Fill 1 Gap Fill 2 U -Factor Res SHGC (max) VT (max) Inswing Double Clear Standard Air 0.46 0.34 0.36 Terrace Door Double Clear Standard Argon 0.44 0.35 0.36 78 3/4' x 78 3/4' HPI Standard Air 0.35 0.20 0.32 (2000 mm x 2000 mm) HP1 Standard Argon 0.33 0.20 0.32 ' HPI Thermal Edge Air 0.35 0.20 0.32 HP1 Thermal Edge Argon 0.32 0.20 0.32 Double Sun 140 Standard Air 0.36 0.12 0.17 � Double Sun 140 Standard Argon 0.33 0.12 0.17 Outswing Double Clear Standard Air 0.45 0.35 0.36 I Terrace Door Double Clear Standard Argon 0.43 0.35 0.36 78 3/4' x 78 3/4' HP1 Standard Air 0.35 0.20 0.32 (2000 mm x 2000 mm) HP1 Standard Argon 0.32 0.20 0.32 HP1 Thermal Edge Air 0.34 0.20 - 0.32 HP1 Thermal Edge Argon 0.31 0.20 0.32 Double Sun 140 Double Sun 140 Standard Standard Air Argon 0.35 0.32 0.13 0.12 0.17 0.1 ) I, Inswing R Q 0.45 0.34 0.35 French Door Double Clear "Standard Argon 0.44 0.34 0.35 78 3/4' x 78 3/4' HPI Standard Air 0.35 0.19 0.31 (2000 mm x 2000 mm) HP1 Standard Argon 0.33 0.19 0.31 ' HP1 Thermal Edge Air 0.35 0.19 0.31 0; HPI Thermal Edge Argon 0.32 0.19 0.31 1 Double Sun 140 Standard Air 0.35 0.12 0.17 f Double Sun 140 Standard Argon 0.33 0.12 0.17 Outswing ` ` ` '.Double Clear 'Standard Air 0.45 0.34 0.35"` •l• French Door Double Clear Standard Argon 0.43 0.34 .0 .35 783/4' x 78 3/4 HPI Standard Air 0.35 - c 0.20 0.31 _ 1'(2000 mm x 2000 mm) , HPI u 'Standard A�god 0.32 0.19 0.31 1 '•'" HP1 Thermal Edge Thermal Edge Air Aigon 034 031 0.20 0.19 ' -0.31 _ 0.31, ; J �"-`, �.- Double Sun.140 Standard Air xY 0.35 0.13 0.17 Double Sun 140 Standard Argon 0.32 0.12 0.17 10 O Product Type YP Size GlazingTotal Window r U (W/m'K) LL Non Clad French Door Transom & Sidelight 2429 mm x 2065 mm HPI [3-12-3 Low E' 172 (52) Argon] 1.7 - Metal Clad French Door Transom & Sidelight 2429 mm x 2065 mm HPI [3-12-3 Low E' 172 (S2) Argon) 1.8 Non Clad French_Door & Sidelight 2429 mm x2065 mm HPI [3-12-3 Low E'172 (S2) Argon) 1.7 c %=; Metal Clad French Door & Sidelight,,--'- 2429 -mm x 2065 mm .. - _ 01'[3-12-3 Low E' 172 (S2) Argon) 1.8 Product Type Air Leakage Water Leakage Structural Terrace Door (2 panel) A-4 0.96 m'/h/m' . - W-2 ® Upper limit = 230 Pa S-7 ® Upper limit = +3600 Pa .; ® 100 Pa ® Lower limit ,= 70 Pa.: ®lower limit = -3600 Pa All i _ r• E r ' -- - - .r w , o - t- ... �,. • 1, �. � L r 3 s