Loading...
BMCH2017-042778-495 CALLE TAM PICO C 0 D "�it�1ILICIJ LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: MECHANICAL/ Application Number: BMCH2O17-0427 Property Address: 44785 CALLE PLACIDO APN: 604381028 Application Description: CERVANTEZ / HVAC CHANGEOUT 14SEER/ 81 AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $7,200.00 Applicant: IFF nMENDEZ AIR CONDITIONING & HEATINGP 0 BOX •871 THOUSAND PALMS, CA 92276 EP 21 2017 ITY COMMUNITY L EAPq NT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisi ns of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Pr essions Code, and my License is in full force and effect. License Cl as C20 License No.: 791437 ,Date.-. �/ Qom tor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her -own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. '(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec.._ B.&P.C. for this reason Date Owner: CONSTRUCTION.LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/21/2017 Owner: HORTENCIA C=RVANTES , 92253 Contractor: MENDEZ AIR CONDITIONING & HEATING P0BOX 871 THOUSAND PALMS, CA 92276 (760)343-5047 Llc. No.: 7914_7 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one -of the following declarations: I have and will maintain a certific; to of consent to self -insure for workers' compensation, as provided for by Section 37-30 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and, will maintain workers' :ompensation insurance, as required by Section 700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: FARMERS INSURANCE EXCHANGE Policy Number: C09242175 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should becom bject to the workers' compensation provisions of Sectior 3700 of the Lab ode,1 II forthwith comply witch t se provisions. Date: / �r Applican WARNING: FAILURE TO SECURE WORKERS' OOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,1300). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE ­ INTEREST, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to :he Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this apoication is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the Citi of La Quinta, its officers, agents, and employees for any act or omission related tothe work being performed under or following issuance of this permit. 2. Any permit issued as a result of this appfcation becomes null and void if work is not commenced within 180 days from date of issjance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county orotnances and state laws relating to building construction, and hereby authorize represematives of this city to enter u o ove- mentioned p per y for inspection purposes.. Date: a� / ure-(Ap Signatplicant.o� Age; Date: 9/21/2017 Application Number.: BMCH2O17-0427 Owner: Property Address: 44785 CALLE.PLACIDO HORTENCIA.CERVANTES " APN: 604381028 . Application Description: CERVANTEZ / HVAC CHANGEOUT 14SEER/ 81 AFUE SPLIT SYSTEM 92253 Property Zoning: Application Valuation: $7,200.00 • 1 Applicant:, Contractor: MENDEZ AIR CONDITIONING &'HEATING MENDEZ AIR CONDITIONING & HEATING P0BOX 871 P0BOX 871 THOUSAND PALMS, CA 92276 THOUSAND PALMS, CA 92276 (760)343-5041 Llc. No.: 791437 Detail: HVAC CHANGE OUT - 14SEER/81AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) T0. BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT,- SPLIT-SYSTEM 101-0000-42402 0 $76.00 DESCRIPTION ACCOUNT QTY AMOUNT- HVAC CHANGEOUT - SPLIT-SYSTEM PC 101-0000-42600 0 $38.00 Total Paid for CHANGEOUT: .-$114.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 . Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5:00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 n Bin# City of La Quinta Building & Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit# Project Add ses:. .. % Oer-s Na: ne1- A.P. Number Address L-I LI Z�S Ca I I A� �C� Legal Description: City,_ST,,-Zi ✓ u I -AQ vllk� Contractor-: Telephoner Address:] 0 X , Project ?:e cript�,io`n. [a-o' (2h 9 a_) 11 �!/ ✓t L ►2 Tele hone p j i.a State,i ic.-#: L City,Lic Arch, Engr., Designer: Address: City, ST, Zip: Telephone: Construction Type: Proj. Type New Add'n Occupascy: Alter, Repair Demo State Lic. #: Name of Contact') t�t SgFt: #Stories # Units: Telephone of Cofitiqf�:-1 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Req'd TRACKING PERM17 FEES Plan Sets Plan Check Submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit: Truss Calcs Called Contact Person Plan Check Balance: Title 24 Calcs Plans Picked Up Construction: Flood Plain Plan Plans Resubmitted Mechanical: Grading Plan 2nd Rev, Ready for corrections / Electrical: Subcontractor List Called Contact Person Plumbin;: Grant Deed Plans Picked Up S.M.I. HOA Approval Plans Resubmitted Grading IN-HOUSE 3rd Rev, Ready for corrections / Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Apps Date of permit issue School Fees Total Pen-nit Fees CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 3) Project Name: 44785 Calle Placido, La Quinta, CA 92253 Date Prepared: 2017-09-21 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name 44785 Calle Placido, La Quinta, CA 92253 02 Date Prepared 2017-09-21 03 Project Location 44785 Calle Placido, La Quinta, CA 92253 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name 44785 Calle Placido, La Quinta, CA 92253 1 Dwelling Unit Conditioned 1 talk g a 07 Zip Code 92253 ! 08 Floor Area (ft)2204 SC System SC System CFA served i refrigerant Installing new SC Installing Installing Installing Identification or Number of Space by this SC 09 Climate Zone `; 15 / 1 . _ - - 10 Conditioning (SC) Systems in 1 Name _ r - _ System (ft) this Dwelling Unit: component? IF I- 9 L z -I,- ",., 3 !.-- 7 C_--% N -.-',-"I r- it I- - 1 ti B. Space Conditioning (SC) System Inf jma .� 01 02 03,'� .om. 04 1 .Ju Ji `�...i' 05 w..w.c. Fw' 'le..?✓ 06 .M —0 07 ..,M 09 10 j ,% * �;� X08 llk(s the SCT 1 talk g a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 2204 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 217-A020325828A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: Report Version: 2016.1.006 Schema Version: rev 10/16 2017-09-21 05:42:42 HERS Provider: CalCERTS Report Generated: 2017-09-21 08:42:21 CERTIFICATE OF COMPLIANCE CFiR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 1501(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new Less than or System 1 furnace heating AFUE 81 AC cooling SEER 14 Setback equal to 40 R-8 components components feet Required Documentation: MR -MCH -01-E - Space Conditioning Systems !A - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -leakage rate compliance: <= 15% or <=10% leakage to outside, or seal all accessible leaks. CF2R and CF311-1VICH-25-1-1 Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF311-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH -25 is required. Exceptions: ' Duct systems registered with HERS provider aspreviously sealed are exempt from MCH -20 Duct Leakage Testing,requirements. w Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH=23 or'Refrigerant`Charge MCH=25� -Existing duct systems constructed, insulated or sealed with asbestosare exempt from MCH=20 Duct`Leakage Testing requirements. SS i �� i[ J t t E '1 v - 1 E i E i k 1 f . J i 1 I 1 E. 1 f k\1 E. Entirely New or Complete Replacement Duct,System, with .or without,Equipment Changeout (Sections 150.2(b)1Diia;and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)SC) This section does not apply to this project. Registration Number: 217-A020325828A-000-000-0000000-0000 Registration Date/Time 2017-09-21 05:42:42 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-09-21 08:42:21 Schema Version: rev 10/16 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: /%(ems � Mendez, Enrique w- c O Company: Signature Date: MENDEZ AIR COND & HEATING 2017-09-21 05:42:42 Address: CEA/ HERS Certification Identification (if applicable): P 0 BOX 871 City/State/Zip: Phone: THOUSAND PALMS CA 92276 A 760-343-5041 Responsible Person's Declaration statement's I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate Jof Compliance is true and correct. 2. 1 am eligible under Division 3 of.the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials; components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulation_s�� E } 4. The building design features or system design features identified on this Certificate of Compliance are entwdh-the information -provided on otherapplicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval this bwlding permit application. v 1 S. I will ensure that a registered copy of this Certificate of:Compllance shall be;marJe,available withahe building:pgrmit(s) issued fortthe building, ant al available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Complliance is ;required to be included with the,documentation. he,builder p,covides to the building owner at occupancy. Responsible Designer Name:` `w Responsible De"'signer Signature: �° '- Mendez, Enrique Company: Date Signed: MENDEZ AIR COND & HEATING 2017-09-21 05:42:42 Address: License: P 0 BOX 871 791437 City/st-ate/Zip: Phnno- THOUSAND PALMS CA 92276 1760-343-5041 Easy to Verity aatIffil at CaICERTS.00m Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies PSI a Registration Provider responsibility for the accuracy of the information. Registration Number: 217-A020325828A-000-000-0000000-0000 Registration Date/Time: 2017-09-21 05:42:42 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006 Report Generated: 2017-09-21 08:42:21 Schema Version: rev 10/16