Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
07-2445 (SFD)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00002445 Property Address: 52300 ROSS AVE APN: 767 -200 -998 -6 -330761 - Application description: DWELLING - SINGLE FAMILY Pronerty 7nnin0: LOW DF_,NRTTY RESIDENTIAL Application valuation: 858337 Applicant: Cb c&ty/ 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: MR/MRS FRIEDRICH 5 MIRADA CIR. DETACHED RANCHO MIRAGE, CA 92270 Architect or Engineer: Lic. No.: OOR SQUARE FOOT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am lic sed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busi s d Pr essionaIs e, and my License is in full force and effect. License Class: 13 No.: 673385 Date' 17ZW —D- _. Con OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Contractor: STROTHER CONSTR CO, INC. 1 MIRADA CIRCLE (760)770-5501 o Lic. No.: 673385 /qL VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/28/07 WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: rA _ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the -work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 7130009332 I certify that, in the performance of the. work for which this permit is issued, I shall not employ any person in any manner so to become bject to the workers' compensation laws of California, and agree that, if I shou be a sub' ct to the orkers' compensation provisions of Section 3700 of the Labor Co I all fon ' h those provisions. Date:�h/-� -:0 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such perm' or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that th o nformatio is correct. I ee to comply with all city and county ordinances and state laws relating to bu' ng nstructio an h e representatives of this county to enter upon the above-mentioned prop inspectio as. Date:'.�r—Signature-(Applicant or Agent)' - Application Number. . . . . 07-00002445. Permit . . . . . BUILDING PERMIT Additional desc . Permit Fee. 2456.50 Plan Check Fee 1596.73 Issue Date . . . . Valuation 638468 Expiration Date .. 5/26/08 Qty Unit Charge Per Extension BASE FEE 2039.50 ]:39-00 3-0000 --------------------=-=----------------------------------------------------- THOU BLDG-500,001-1,000,000 417.00 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Feer 504.68 Plan Check Fee 126.17 " Issue Date . . . . Valuation . . . . 0 Expiration Date 5/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 8196.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 286.86 9391.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 187.82 1.00 15.0000 ---------------------------------------------------------------------------- EA ELEC TEMPORARY POWER POLE 15.00 Permit. . • • • GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/26/08 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 188.00 Plan Check Fee 47.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/26/08 Qty. Unit Charge Per Extension BASE FEE 15.00 6.00 9.0000 EA MECH FURNACE <=100K 54.00 6.00 9.0000 EA MECH B/C <=3HP/100K BTU 54.00 9.00 6.5000 EA MECH VENT FAN 58.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 LQPERMIT Application Number 07-00002445 Permit . . . . . . PLUMBING _ Additional desc . Permit Fee . . . . 330.75 Plan Check Fee 82.69 Issue Date . . . .. . Valuation . . . . 0 Expiration Date 5/26/08 Qty Unit Charge Per Extension BASE FEE 15.00 39,00 6,.0000 EA PLB FIXTURE 231:00 1.00 15.0000 EA PLB BUILDING SEWER 15.00' 2.00 6.0000 EA PLB ROOF DRAIN 12.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 17.00 .7500 EA PLB GAS PIPE >=5 12.75 1.00 15.0000 EA PLB GAS METER 15.00 ----------------- ---------------------------------------------------------- Special Notes and Comments 8196 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH L ----------------------------- O,ther Fees . . . ---------------------------------------------- . . . . ART IN PUBLIC PLACES -RES 1645.84 DIF COMMUNITY CENTERS -RES 74.00 DIF.CIVIC CENTER - RES 995.00, ENERGY REVIEW FEE 159.67 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE 15.00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 85.83 DIF STREET MAINT FAC -RES. 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited ------------------------------------- Due Permit Fee Total -------------------- 3494.93 .00 .00 3494.93 Plan Check Total 1852.59 750.00 .00 1102.59 Other Fee Total 6381.34 .00 .00 6381.34 Grand Total 11728.86 750.00 .00 10978.86 LQPERA11T Building2 „0 Address 6-22 . SCJ T4hf 4 4 " P.O. BOX 1504 78-495 CALLE TAMPICO WGNAe LA QUINTA, CALIFORNIA 92253 Ms V2iF,DeICl+ Address MICAVA diF_f,LK� I •> 7a 1-270 -SSRI & Classif. (o73?J$S Lia # Arch., Engr., n Designer DAVO Q, OL oN Aiece-,McM 7D WA4b RYq qS'a City zip State G ,��2� 9 .&W Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip APPLICATION ONLY BUILDING: TYPE CONST. GCC. GRP. A.P. Number 76 7 % 70 DTZ�j Legal Description � 6A 1 ".e'i 5307(6-1 Project Description ST=b Sq. Ft.No. No. DIN. Size ��� Stories Z Units New;S Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. J2� 1--111111 Infrastructure OF LAW.NANCE TOTAL REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setbacl• from Center Line Side Setback from 3roperty Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Certificate of OccupancY F Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City, regulating building construction and/or use. BUILDING ADDRESS: 52-300 ROSS AVENUE Use classification: SINGLE FAMILY DWELLING Occupancy Group: R3 Type of Construction: VN Owner of Building: MR./MRS. FRIEDRICH Building Official POST IN Building Permit No.: 07-2445 Land Use Zone: RL Address: 5 MIRADA CIRCLE City, ST, ZIP: RANCHO MIRAGE, CA 92270 By: KIRK KIRKLAND Date: MARCH 19, 2009 Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MMGATIONAMOUNT: COMMAND. AMOUNT: DATE: RECEIPT:-' CHECK#: IMTIAIS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Residence is at the Madison Club Date: November 28, 2007 Owner's Name: Mr. Freidrich Phone No. Project Address: 52-300 Ross Avenue La Quinta, CA Project Description: SFD APN: 676-670-026 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 8,196 sq. ft. Certification of Applicant/Owners: The person signing certif es that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authori#(hto sign oA behalf, of the owner/developer. Dated: 11-28-07 Signature: \ . "�M1 *********************************************************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code. Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement N=ote•, Number of Sq.Ft. 8,196 Amount per. Sq.Ft. $3.48 Amount Collected $28,522.08 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services Certificate issued by: Elvira Mattson, Secretary_ III Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions (G°Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. N1V:c/mydocs/devfees/certificate of compliance form tablesTO USE.doc 1/16/03 T WEDDLE SURVEYING MAPPING, INC. • Boundary • Construction • Topographic • Aerial Surveys -ALTA Surveys -GPS- Consulting February 1, 2008 Mr. Timothy R.-Jonasson Public Works Director / City Engineer City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253-1504, Re: Pad/Form Grade Verification City of La Quinta FREIDRICH RESIDENCE Lot 6A Lot 6 Tract No. 33076-1 Ross Avenue HIDEWAY :�5•2r 300 . APN 767-670-026. Dear Mr. Jonsson: • We have performed a field survey to determine the vertical location of the Building Pad and Building Form for the above referenced project. The elevations observed areas follows: PAD (DESIGN) PAD (AS -BUILT) " 1007.5 - 1007.5 FORM (DESIGN) FORM (AS -BUILT) _ 1008.00 1008".00 - These field observations are in substantial conformance with the Precise Grading Plan prepared by ESSI SHAHANDEH, CIVIL ENGINEER, dated 10/16/07, approved by the City of La Quinta- Building & Safety Department and the building horizontal location substantially conforms to the required setbacks and site layout as shown on the approved site plan. Sincerely, O %,AND S� WEDDLE SURVEYING MAPPING, INC. V 0 NO. 5570 EXP. 09/30/09 _ David -L. Weddle, President L.S. 5570, exp.09/30/09 • P.O. Box 10418 • Palm Desert, CA 92255-0418 77-725 Enfield Lane, Ste. 140 • Palm Desert, CA 92211 � 760.360.5570 E -Mail: WedSurv@aol.com aol.com • Fax 760.360.5573 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 5) CF -4R Project Address l Chris Friedrich Res I Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values Builder / Installer 52-300 Ross Avenue / La Quinta / CA / 92253 Enter Tested Leakage Flow in CFM 46 Strother Construction Co. Builder/ Installer Contact Telephone Plan Number / Permit Number Charles Strother 7605675851 Plan 0702 HERS Rater Telephone Sample Group Number Jack LaFontaine:. CIHIE IRISO ID #CCNJL348610 7603604631 0 Com,pfffnce ethod (Pres i five) 9 Climate Zone 15 C tify g Date Sample House Number ❑ Pass ❑ Fail -/� -,69 Lot 6A rm 12 HERS Provider ergy Management Services CIHIEIEIRIS® Address City/State/Zip 41-485 Adams St., Unit C Indio /CA /92203 Copies to: BUILDER, HERS PROVIDER AND BUILDING DEPARTMENT 1 HERS RATER COMPLIANCE STATEMENT This house was: f Tested As the HERS rater providing diagnostic testing and field verification, I certify that the house identified on this form complies with the diagnostic tested compliance requirements as checked on this form. The HERS rater must check and verify that the new distribution system is fully ducted and correct tape is used before a CF -4R may be released on every tested building..,The HERS rater inust not release the CF -4R until a properly completed and signed CF -6R has been received for the sample and tested buildings. �f / The installer has provided a copy of CF -6R (Installation Certificate). !�� V New Ducts are fully ducted (i.e., does not use building cavities as plenums or platform'retums in lieu of ducts). / New ducts with cloth backed, rubber adhesive duct tape is installed, mastic and'draw bands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. �. V MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Procedures for field verification and diagnostic testing of air distribution systems are available in RA CM, Appendix RC4.3. 1 Duct Diagnostic Leakage Testing Results System # 1 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM 46 Fan Flow: Calculated (Nominal: V Cooling ❑Heating ❑Measured) 1200 Enter Total Fan Flow in CFM: 3 Pass if Leakage Percentage < 6% [ 100 x [ Line #1 / Line #2 ] ] 3.80% f Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior. to Duct /111 System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. _ ' _ I , t 'N'\ 6 Enter Reduction in Leakage for Altered Duct System [ Line #4 Minus Line #5] (Only,if Applicable). 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable). 8 Enter New Duct System - Pass if Leakage Percentage < 6% [ 100 x [ Line #5 / Line #2 ] ] ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Out Use one of the following.four Test or Verification Standards for Compliance 9 Pass if Leakage Percentage < 15% [ 100 x [ Line #5 / Line #2 ] ] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x [ Line #7 / Line #2 ] ] ❑ Pass ❑ Fail 11 Pass if Leakage Reduction Percentage > 60% [ 100 x [ Line #6 / Line #4 ] ] and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if One of Lines #9 through #12 Pass ❑ Pass ❑ Fail Residential Compliance Forms Generated by CIHIEIEIRISO http://www.CHEERS.org December 2005 1 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 2 of 5) ' CF -4R Project Address I Chris Friedrich Res I 52-300 Ross Avenue / La Quinta / CA / 92253 Builder / Installer Strother Construction Co. System # 2 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM 112 2 Fan Flow: Calculated (Nominal: / Cooling O Heating O Measured) Enter Total Fan Flow in CFM: 2000 _ 3 Pass if Leakage Percentage < 6% [ 100 x [ Line #1 / Line #2 ] ] 5.60% /Pass Cl Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter.Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. 6 Enter Reduction in Leakage for Altered Duct System [ Line #4 Minus Line #5] (Only if Applicable). 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable). �_ 8 Enter New Duct System - Pass if Leakage Percentage < 6% [ y100 x [.Line #5 / Line #2 ] ] ❑ Pass 0 Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System 'and/or.HVAC Equipment Change -Out Use one of the following four Test or Verification Standards for Complian e J 9 Pass if Leakage Percentage < 15% [ 100 x [Line #5 / Line #2 11, � . r [ ❑ Pass 0 Fail C3 Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10%'•[ 100 x [ Line #7 /,Line #2 ].] ! j ( y. O Pass ❑ Fail C3Pass 0 Fail I 1 Pass if Leakage Reduction Percentage > 60% [ 100 x [Line #6 / Line!#4 ],] and Verification by Smoke Test and Visual Inspection O Pass 0 Fail O Pass ❑ Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection-,- 0 Pass ❑ Fail ❑ Pass ❑ Fail Pass if One of Lines #9 through #12 Pass Pass if One of Lines #9 through #12 Pass ❑ Pass O Fail O Pass ❑ Fail System # 3 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM 121 2 Fan Flow: Calculated (Nominal: V Cooling 0 Heating O Measured) Enter Total Fan Flow in CFM: 4000 3 Pass if Leakage Percentage < 6% [ 100 x [ Line #1 / Line #2 ] ] 3.03% f Pass O Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. , I &'.1 . 6 Enter Reduction in Leakage for Altered Duct System [ Line #4 Minus Line #5] (Only,if Applicable). ; 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable). i ! . I ; r �_ 8 Enter New Duct System - Pass if Leakage Percentage < 6% [ 100 x [ Line #5 / Line #2 ] O Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change-Ou� J Use one of the following four Test or Verification Standards for Compliance 3 �, I �� I 9 Pass if Leakage Percentage < 15% [1100 x [ Line #5 / Line #2 ] ] ' f ! ❑ Pass 0 Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x [ Line #7 / Line #2 ] ] O Pass ❑ Fail 1 I Pass if Leakage Reduction Percentage > 60% [ 100 x [ Line #6 / Line #4 ] ] and Verification by Smoke Test and Visual Inspection O Pass 0 Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection 0 Pass ❑ Fail Pass if One of Lines #9 through #12 Pass ❑ Pass O Fail Residential Compliance Forms Generated by CJHJEJEJRJS® http://www.CHEERS.org December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 3 of 5) CF -4R Project Address I Chris Friedrich Res I 52-300 Ross Avenue / La Quinta / CA / 92253 Builder / Installer Strother Construction Co. System # 4 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM 110 2 Fan Flow: Calculated (Nominal: V Cooling O Heating ❑ Measured) Enter Total Fan Flow in CFM: 2000 _ 3 Pass if Leakage Percentage < 6% [ 100 x [ Line #1 / Line #2 ] ] 5.50% f Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM: Final Test of New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. 6 Enter Reduction in Leakage for Altered Duct System [ Line #4 Minus Line #5] (Only if Applicable). 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable). 8 Enter New Duct System - Pass if Leakage Percentage < 6% [.1O - 0 x [•Line_#5 / Line #2 ] ] ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or,HVAC Equipment Change -Out Use one of the following four Test or Verification Standards for C6mpliance% 9 Pass if Leakage Percentage < 15% [ 100 x [Line #5 /Line #2 ] ]> � r f ❑ Pass 0 Fail 10 Pass if Leakage to Outside Percentage < 10%<[t100 x [ Line #7 /.Line #2 ].]. t ❑ Pass ❑ Fail 11 Pass if Leakage Reduction Percentage > 60% [ 100 x [-Line #6 / Line #4,].] and Verification by Smoke Test and Visual Inspection,,//���. 0 Pass ❑ Fail 12 Pass if Sealing of all Accessible Leaks and .Verification by Smoke Test and Visual Inspection! ❑ Pass ❑ Fail L : 'Pass if One of Lines #9 through#12 Pass11 J ❑Pass ❑Fail System # 5 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM 119 2 Fan Flow: Calculated (Nominal: V Cooling 0 Heating ❑ Measured) Enter Total Fan Flow in CFM: 2000 II 3 Pass if Leakage Percentage < 6% [ 100 x [ Line #1 / Line #2 ] ] 5.96% V Pass ❑ Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from CF -6R: Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM: Final Test of. New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. 1 6 Enter Reduction in Leakage for Altered Duct System [ Line #4 Minus Line #5] (Only, if Applicable). 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable). , m - j 1 , ' . C 8 1 Enter New Duct System - Pass if Leakage Percentage < 6% [ 100 x [ Line #5 / Line #2 ] ] I `� ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change -Outs Use one of the following four Test or Verification Standards for Compliance- —J 9 Pass if Leakage Percentage < 15% ['100 x [ Line #5 / Line #2 ] ] { ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x [ Line #7 / Line #2 ] ] ❑ Pass ❑ Fail 11 Pass if Leakage Reduction Percentage > 60% [ 100 x [ Line #6 / Line #4 ] ] and Verification by Smoke Test and Visual Inspection 0 Pass ❑ Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection 0 Pass ❑ Fail Pass if One of Lines #9 through #12 Pass J 0 Pass ❑ Fail 0 Residential Compliance Forms Generated by CJHJEJEJRJS© http://www.CHEERS.org December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 4 of 5) CF -4R Project Address I Chris Friedrich Res I 52-300 Ross Avenue / La Quinta / CA / 92253 Builder / Installer Strother Construction Co. THERMOSTATIC EXPANSION VALVE (TXV) Procedures for field verification of thermostatic expansion valves are available in RA CM, Appendix RI. System # 1 f Yes ❑ No Access is provided for inspection. The procedure shall consist of visual verification that the TXV is installed on the system and installation of the specific equipment shall be verified. Yes is a pass f pass ❑ Fail System # 2 f Yes ❑ No Access is provided for inspection. The procedure shall consist of visual verification that the TXV is installed on the system and installation of the specific equipment shall be verified. Yes is a pass �/ Pass ❑ Fail System # 3 , V Yes ❑ No Access is provided for inspection. The procedure shall consist of visual verification that the TXV is installed on the system and installation of the specific equipment shall be verified. R I 1 - ,-I Yes is a pass / Pass O Fail System # 4 / Yes O No Access is provided for inspection. The procedure shall consist of visual verification that the TXV is installed on the system and - E_ ._-_ Yes is a pass f Pass O Fail installation of the specific equipment shall be verified. _ 11� i 1 n Yes is a pass �/ Pass ❑ Fail System # 5�� �/�•/,��`��`� r1� Y/ Yes ❑ No Access is provided for inspection.,The procedure shall consist of visual verification that the TXV is installed on the system and installation of the specific equipment shall be verified. = ; { t i �. } - E_ ._-_ Yes is a pass f Pass O Fail t v/ HIGH EER AIR CONDITIONER W ! y ~ y Procedures for verification are available in RA CM, Appendix RL System # 1 I v/ Yes ❑ No EER Values of installed systems match the CF -IR 2 �/ Yes ❑ No For split system, indoor coil is matched to outdoor coil 3 O Yes ❑ No Time Delay Relay Verified (If Required) Yes to I and 2; and 3 (If Required) is a pass �/ Pass O Fail System # 2 - I V Yes ❑ No EER Values of installed systems match the CFAR ' _ _ 1k Uly 2 V Yes ❑ No Forsplit system,•indoor coil is matched to outdoor coil ' f 1' ✓ 3 O Yes ONO Time Delay Relay Verified (If Required) Yes to 1 and 2; and 3 (If Required) is a pass �/ Pass ❑ Fail System # 3 1 1 — I - - I •—, I =-J ,. I / Yes ❑ No EER Values of installed systems match the CF -1R T i 2 ✓ Yes O No ' For split system, indoor coil is matched to outdoor coil 3 ❑ Yes ❑ No Time Delay Relay Verified (If Required) Yes to 1 and 2; and 3 (If Required) is a pass I V Pass ❑ Fail System # 4 I /Yes ' O No EER Values of installed systems match the CF -1R 2 v/ Yes ❑ No For split system, indoor coil is matched to outdoor coil 3 ❑ Yes ❑ No Time Delay Relay Verified (If Required) Yes to 1 and 2; and 3 (If Required) is a pass �/ Pass ❑ Fail d Residential Compliance Forms Generated by CJHJEJEJRJS® http://www.CHEERS.org December 2005 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 5 of 5) CF -4R Project Address 1 Chris Friedrich Res 1 52-300 Ross Avenue / La Quinta / CA / 92253 Builder / Installer Strother Construction Co. Svstem # 5 I V Yes ❑ No EER Values of installed systems match the CF -IR 2 V Yes ❑ No For split system, indoor coil is matched to outdoor coil 3 Cl Yes ❑ No Time Delay Relay Verified (If Required) Yes to I and 2; and 3 (If Required) is a pass �/ Pass ❑ Fail Residential Compliance Forms Generated by CJHJEJEJRJSO http://www.CHEERS.org December 2005 Mar 12 09 09:10a Jack LaFontaine INSTALLATION CERTIFICATE INSTALLER COMPLIANCE STA 760-360-3074 ��— (Pa g e 4 o f 12) Permit Number JT FOR DUCT LEAKAGE p.2 CF -6R INSTALLER CO.MPI DANCE STATEMENT The building was:-'Vted at Final V ❑ Tested at Rough -in I1 STALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE FOR NEW DUCTS: Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing �Wwall are properly sealed. -If the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection points are properly sealed. Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used on new ducts. ✓04X�CT LEAKAGE REDUCTION P.v,..nd..rvc r— rotd .:o►;rrra/inn and dinounctir iocrinn nfair dicrrihn-tinn systems are available is RACA?. ADDendix RC4.3 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM ([t7, 25 Pa) Measured V slues 1 Enter Tested Leakage Flow in CFM: /;r Fan Flow: Calculated (Nominal: ling ✓ 0 Heating) or ✓ ❑ Measured 2 If Fan Flow is Calculated as 400 cfm/ton x number of tons or as 21.7 cfm/(kBtu/hr) x Heating G vo ✓ ✓ Cavacity in Thousands of Btu/hr, enter total calculated or measured fan flow in CFM here: Pass if LeakaAF Percentage < ° for Final or < 4% at Rough -in without air handle: (F ❑Fail ' 100 x Line # 1) GOG Line# 2)11 ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct 4 System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct ` S stem for Duct System Alteration and/or Equipment Change -Out. Enter Reduction in Leakage for Altered Duct Svstem 6 Line # 4) Minus Line # 5) — (Onlyif Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ ✓ Entire New Duct System - Pass if Leakage Percentage < 6% for Final. ❑ Pass ❑ Fail S 100 x (Line 4 5 / Line # 2)11 TEST OR VERIFICATION STANDARDS: For Altered Duet System and/or HVAC Equipment Cha age- ✓ ✓ Out Use one of the following four Test or Verification Standards for compliance: 9 I Pass if Leakage Percentage < 15% [100 x [ (Line # 5) / (Line # 2)]] 13Pass 0 Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x f _ (Line # 7) ! (Line # 2)]] p Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [ 100 x [—(Line # 6) i (Line # 4)]] p Pass 0 Fail l l and Verification by Smoke Test and Visual Inspection 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass O Fail Pass if One of Lines # 9 through # 12 pass Pass ❑ Fail nders fined, verify that the above diagnostic test results were performed in conformance with the- requirements for compliance crtydit. 1, the undersigned, also certify that the newly installed or retrofit Air -Distribution System Ducts, Plenums and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor Co. Name) OR Genera] Contractor Ne) OR Owner Signature: Date: 46 Copies to: BUILDING DEPARTMENT, ITERS R4TER (IF APPLICABLE) BUILDING ORTER AT OCCUPANCY Residential Compliance Forms December 2005 Mar 12 09 09:10a Jack LaFontaine 760-360-3074 p.3 INSTALLATION CERTIFICATES (Page 4 of 12) CF -6R Sim Address A PermitNumber G /&) 1/1 INSTALLER COMPLIANCE 'ATEMENT FOR DUCT LEAKAGE INSTALLER COMCE STATEMENT The building was: ted at Final ✓ ❑ Tested at Rough -in AA ove at VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE FOR NEW DUCTS: mleast one supply and one retum register, and verify that the spaces between the register boot a -ad the interior finishing -wall are properly sealed. If the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the /-wr handler and the supply and return plenums to verify that the connection points are properly sealed. `Ja Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used on new ducts. CT LEAKAGE REDUCTION s for field n"Vkadon and diarnostic tettinr of air distribudan systenn are availahie in RACW_ Anno fir RCA3 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM Q 25 Pa) Measured Signature: Date: 6 Va_ues I Enter Tested Leakage Flow in CFM: 2 Fan Flow: Calculated (Nominal: Cooling v/ ❑ Heating) or - ❑ Measured 2 If Fan Flow is Calculated as 400 cfm/ton x number of tons oras 21.7 cfm/(kBtu/hr) x Heating Capaci in Thousands of Btu/hr, enter total calculated or measured fan flow in CFM here: ✓ ✓ 3 Pass if Leakage Percentage <�%a for Final or < 4% at Rough -in without air handle: �: r, s [3 Fail 100 x G (Line R i) � Line 4 2 ALTERATIONS: Duct System and/or HVAC Equipment Change -Out Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct 4 System Alteration andlor Equipment Change. -Out. Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct 5 System for Duct System .Alteration and/or Equipment Chan -Out. Enter Reduction in Leakage for Altered Duct System 6 (Line # 4) Minus Line # 5 — (Only if Applicable) 7 Enter Tested Leakage Flow in CEM to Outside (Only if Applicable) ✓ ✓ 8 Entire New Duct System - Pass if Leakage Percentage < 6% for Final. ❑Pass 13 Fail 100 x Line # 5) / Line # 2 TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change- ✓ Out Use one of the following four Test or Verification Standards for com lionce: 9 Pass if Leakage Percentage < 15% [100 x [ (Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail ] 0 Pass if Leakage to Outside Percentage < 10% [100 x [„__ (Line # 7) / (Line # 2)]] 13 Pass O Faii Pass if Leakage Reduction Percentage > 60% [ 100 x (_(Line # 6) / (Line # 4)]] 11 and Verification by Smoke Test and Visual Inspection ❑ Pas El Fail 12 Pas if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail Pass if One of Umes # 9 throu # 12 pass IbZ Pass ❑ Fail ✓;Fr,-* -undersigned, verify that the above diagnostic test results were performed in conformance with the requirernentsIor compliance credit. 1, the undersigned, also certify that the newly installed or retrofit Air -Distribution System Ducts, Plenums and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor (Co. Name) OR General Contractor (q. Na e) OR Owner Signature: Date: 6 Copies to: BUILDING iWPARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms December 2005 Mar 12 09 09:11a Jack LaFontaine INSTALLATION CERTIFICATE .SCA Si; Address _ 2-�F6�L' f v f�"u2: , twit: INSTALLER COMPLIANCE STA 760-360-3074 p.4 (Page 4 of 12) CF -6R Permit Number n FOR DUCT LEAKAJE INSTALLER COMPYANCE STATEMENT The building was: l," led at Final ✓ ❑ Tested at Rough -in IVSTALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE FOR NEW DUCTS: ' Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing DW wall are properly sealed. -If the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the /mr handler and the supply and return plenums to verify that the connection points are properly sealed. `,p Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used on new ducts. le ✓ UCT LEAKAGE REDUCTION Procedures forfadd veri icadon and diagnosdiclesting of air distribution sleets are available in RACH A endix RC4 3 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Signature: Date: .L Values 1 Enter Tested Leakage Flow in CFM: Fan Flow: Calculated (Nominal: ✓ Wooling v/ ❑ Heating) or ✓ ❑ Measured 2 If Fan Flow is Calculated as 400 cfn>/ton x number of tons or as 21.7 cfm/(kBtu/hr) x Heating h �'\ Capacityin Thousands of Stull r enter total calculated or measured fan flow in CFM here: V V ✓ ✓ Pass if L e Percentage < 6°o for Final or < 4% at Rough -in without air handle:.Pass 13 Fail [100X Line # I . %Line # 2 p ;; ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct 5 System forDuct System Alteration andlor E ui ment Change -Out. Enter Reduction in Leakage for Altered Duct System 6 r (Line # 4) Minus (Line # 5) — (Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) Entire New Duct System - Pass if Leakage Percentage < 6% for Final. 8 100 x {Line # 5 / Line # 2) D Pass 13Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change - Out Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% 1100 x [ (Line # 5)1 (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [100 x l (Line # 7) / (Line # 21]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage> 600/a [100 x 1 (Line # 6)1 (Line # 4)1] 11 and Verification b Smoke Test and Visual Inspection D Pass Q Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection D Pass ❑ Fail Pass if One of Lines # 9 throu h # 12 ss Pass ❑ Fail ✓ I&L-the undersigned, verify that the above diagnostic test results were performed in conformance with the requirements for compliance cre it. I, the undersigned, also certify that the newly installed or retrofit Air -Distribution System Ducts, Plenums and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor (Co. Name) OR General Contractor (q. Na e) OR Owner Signature: Date: .L Copies to: BUILDING PARTME.NT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPAN--Y Residential Compliance Forms December 200.1 Mar 12 09 09:11a Jack LaFontaine 760-360-3074 p.5 [ INSTALLATION CERTIFICATE -,-7:::- p A)L fe (Page 4 of 12) CF -GR SiN Address ,t l I A „ Permit Number 2--�r6 o kn t INSTALLER COWLIANCE STA' INSTALLERCOMCE STATEMENT The building was; ed at Final ✓ ❑ Tested at Rough -in FOR DUCT LEAKAGE IgSTALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE FOR NEW DUCTS: Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing wall are properly sealed. X,/4f the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the /air handler and the supply and return plenums to verify that the connection points are properly sealed. QI Inspect all joints to ensure that no clods backed rubber adhesive duct tape is used on nets ducts. ✓ DUCT LEAKAGE REDUCTION Promdures for field veririCation and diagnostic &slwp of air &crrihurion cuct"w nro nunirn)do ;- IPA/ -&,t A....a.../:.. D/'.4 : NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured V a. ues Signature: I Enter Tested Leakage Flow in CFM: &10 2 Fan Flow: Calculated (Nominal: ✓ WE ooling ✓ ❑ Heating) or ✓ ❑ Measured If Fan Flow is Calculated as 400 efm/ton x number of tons or as 21.7 cfm/(kBtu/hr) x Heating Capacity in "Thousands of Btu/hr. enter total calculated or measured fan flow in CFM here: !)UOQ ✓ ✓ 3I Pass if Leal -age Percentage <.§% for Final or <4% at Rough -in without air handle: 100 x U (Line # I) c3US Line # 2) (� •'f� V ass ❑Fail ALTERATIONS: Duct System and/or HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. 5 Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct System for Duct System Alteration and/or Equipment Change -Out. 6 Enter Reduction in Leakage for Altered Duct System (Line # 4) Minus "Line # 5 —(Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ,/ 8 Entire New Duct System - Pass if Leakage Percentage < 6% for Final. 100 x ine # 5) / Line # 2 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change - Out Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% (100 x [ (Line # 5) / (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x f (Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail 11 Pass if Leakage Reduction Percentage> 60% [100 x (^_(Line # 6) / (Line # 4)]] and Verification by Smoke Test and Visual Inspection ❑ Pass ❑ Fail 12 Pass if Scaling of all Accessible Leaks and Verification by Smoke Test and Visual Inspection' ❑ eass ❑ Fail Pass if One of Lines # 9 through # 12 pass I ggEass ❑ Fail 4'66t, -Mt -undersigned, verify that the above diagnostic test results were performed in conformance with the requirements for compliance cre8it. 1, the undersigned, also certify that the newly installed or retrofit Air -Distribution System Ducts, Plenu ns and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor Co. Name) OR General Contractor p. Naze) OR Owner i Y" - � �/U'';/' %id Gy/tti Signature: Date: ` i CJ Copies to: BUILDING PARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms December 2005 Mar 12 09 09:11 a Jack LaFontaine 1760-360-3074 p.6 INSTALLATION CERTIFICATE - (Page 4 of 12) CF -6R Sije Address ,r Permit Number t- 1)2- 6 4) f f-i'v2,s cS ' j. C,< 2 r INSTALLER CONIPLIANCE STATEMENT FOR DUCT LEAKA- .F INSTALLER COMP ANCE STATEMENT The building was: nyxwod at Final ✓ ❑ Tested at Rough -in I STALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE FOR NEW DUCTS: Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing wall are properly sealed. if the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handier and the supply and return plenums to verify that the connection points are properly sealed. Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used on new ducts. T LEAKAGE REDUCTION for field verification and diaenosac testine of air distribution systems are avadable in RA[ .V Annem: x RCC3 NEW CONSTRUCTION: - - are - - — - - - RAC - Duct Pressurization Test Results (CFM a@ 25 Pa) Measured Signature: Values 1 Enter Tested Leakage Flow in CFM: Fan Flow: Calculated (Nominal: ✓ ooling ✓ ❑ Heating) or ✓ ❑ Measured 2 If Fan Flow is Calculated as 400 cfiniton x number of tons or as 21-7 cfm/(kBtu/hr) x Heating Capacity in Thousands of Btu/hr, enter total calculated or measured fan flow in CFM here: d ✓ f ' Pass if Lea a Percentage <% for Final or < 4% at Rougb-in without air handle: iS 13 Fail 100 x Line # 1) �V(Line # 2)11 ALTERATIONS: Duct System andlor HVAC Equipment Change -Out 4 Enter Tested Leakage Flow in CFM from Pre -Test of Existing Duct System Prior to Duct System Alteration and/or Equipment Change -Out. Enter Tested Leakage Flow in CFM from Final Test of New Duct System or Altered Duct S stem for Duct System Alteration and/or Equipment Change -Out. Enter Reduction in Leakage for Altered Duct System 6 (Line # 4) Minus Line # 5) -(Only if Applicable) 7 Enter Tested Leakage Flow in CFM to Outside (Only if Applicable) ✓ �/ Entire New Duct System - Pass if Leakage Percentage < 6% for Final. 8 100 x Line # 5) (_Line # 2)11 ❑ Pass ❑ Fail TEST OR VERIFICATION STANDARDS: For Altered Duct System and/or HVAC Equipment Change - Out Use one of the following four Test or Verification Standards for compliance: 9 Pass if Leakage Percentage < 15% (100 x j (Line # 5)1 (Line # 2)]] ❑ Pass ❑ Fail 10 Pass if Leakage to Outside Percentage < 10% [ 100 x I _ (Line # 7) / (Line # 2)]] ❑ Pass ❑ Fail Pass if Leakage Reduction Percentage > 60% [100 x [__(Line # 6) / (Line # 4)]] t 1 and Verification b Smoke Test and Visual Inspection p pass ❑Fail 12 Pass if Sealing of all Accessible Leaks and Verification by Smoke Test and Visual Inspection ❑ ❑ Fail Pass if One of lines # 9 through # 12 pass 1 Mass ❑ Fail ✓ 1107 bc-undersigned, verify that the above diagnostic test results were performed in conformance with the requirements for compliance credit. 1, the undersigned, also certify that the newly installed or retrofit Air -Distribution System Ducts, Plen•:ims and Fans comply with Mandatory requirements specified in Section 150 (m) of the 2005 Building Energy Efficiency standards. Installing Subcontractor (Co. Name) OR General Contractor (Cp. Narge) OR Owner Signature: Daze: 62 Copies to: BUILDING 'PARTMENT, HERS RA,rER(IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms December 2005 Mar 12 09 09:10a Jack LaFontaine 760-360-3074 p.1 INSTALLATION CERTIFICATE (Page 3 of 12) CF -6R Site Address ( Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate Lispections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(a). HVAC SYSTEMS: Heating Equipment ' CEC Certified Mfr. Equip Tyle Name and Model ka..heat pump) N:unber ti of Identical Systems Efficiencyl (AFUE,ele.) ?CF -IR value) Duct Location attic, etc. Duct or Piping R -value Heating Laa9 fewlhr Heating Capacity (Btu,'hrl I ' , D T � G � •2 �i. /l Uy L v 6,6- Qru Q t: --,c- Y 2 afr �'fvo 2v Cooling Equipment CEC Certified Mfr. Equip Type Name and Model (pkg. heat pump) Number Nor Identical Systems Efficiency EER SEER or ) 2CF-1 R value) Dud Location attic, etc. CoolingCoo)in; Duct Load R -value (Illuttr) Capacity 131u/h-1 � nY c1 c r IJVt��L. [} ✓L �G I ' , D T � G � •2 �i. /l Uy 1. > s)Tnbol reads greater than or equal -to what is indicated on the CF -IR value. Include both SEER and EER if compliance credit for high EER air conditioner is claimed. undersigned, verify that equipment listed above is: 1) is the actual equipment installed, 4 equivalent to or m e efficient than that specified in the certificate of compliance (Form CF -111) submitted for compliance with the Energy Efficiency Standards for residential buildingsi and 3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency: Regulations or Part 6), .where a3plicable. Installing Subcontractor (Co. Name) OR General Contractor ( me) OR ner G6 A) la - 5ignawre: Date: `P� 9, h Q Copies to- BUILDING D#ARTMENT, HERS RATER (IF APPLICABLE) BUILDING OWNER AT OCCUPANCY Residential Compliance Forms I April 2005 J le Mar 0PR. 6. 2009 3:19P.%teG GUY EVANS 760398303 NO. 4586 P. 2 JNSTALLAVOK CSRWICATZ Z df LM) CF-. 6"Addaw 10300 R4D55AvL0/111G2 e,41J9,vuin>a e'tYctt►ecr Ao inawfation canitfme is rqu`cAyo taapumd .t dic builQ" tilt br aadt sv�d�bk liirad'app+ppN�{e intpeelivna, (The infott nioi provided on dila Lana is =quhvd) After canpladaa of OrAl im poction. a cWmem be provided b iho bulldial; dcortinW(upon regtwOartdthebA tjoamerwooarptrtoy.par5ecGmt0.tQ3(0. FENESTRATION/CL.Aw(;: "Use vebres rrttm a ferteslr6lion vrodttrl'sNFRiClorti. For fea�wioa ptadaaat wiNoyt an NFltC label, wo tit &bub volues from Section 116 of tha HaM Bf6cieaey 9tuWarLis, tt h llcd Wier; nr must be Ie" dW a eymp110 vahm from CF -IR. Iasmllcd SHCC mutt balm Omer ogoat to vnluba fiats CF-tR, or a shodinedeyies (csOQiQae pvgbaag) is iostand r� sptxlAed oe drt, CI' -11L Atmuallvsl� Iawiliod wciRlttod avttrero l�iaciore fartbe toll fontatradoo alp ire Itsa tll= ar dyaal tk ralucs*9M Cr l It. If utin: deUuh bble •SHGC valuta f-om It 16 Was* vrhadw titdod of votl • r A I, Vtt: t,ttlosiPtk vt* Nut 910 {lased above: my sV.M= )) is the 1&nWa SxcwE im prOduol iwlo "t A) is 601iv*m to or hN a Itrrltt• C•>rbetor ebd lower SHt3C *m ad spot ifi;d in the oWrl" pf om oi&am(FarmCF-1R)subvtlmodforooQtAliawrWMtbeBne►3't►Jlkwwc7&AmfaodrhrMkia"bvudkWwd 3) the pmdwt mmu q- ==do t1r0 apptWdkta negainstkm for r uftfiz asd dtvh= (fasts pat 6), wh6o vppbaWr ltem/is sipuNrc Omtd lasre14n�91maon*ie1Q (Co. Nmga) R (Irappletabk) CCeecal Coatraamr(Co-Ivlmrte)0R OWrW 4tile I OR Window Disthbow Mean !Is 5115FI furs '' Daft )swelling Sa6edntJrer�pr (Co. None) OR (if applkablc) ; tyartatd ConmaK(Co. Nttaeo) OR Owner 0R Windowltiliawibamr Flim ODIC Ituullibg $obooatraaor (C1�Nwn OR (ifopplira►bl� •Gwtarel•Cantreqtw(Co.'Nwm)0 'Ottmer OR Windota►p{ttributor Copies to; BsiGling Oqurunao, HERS Ralir ()f apOCOle) Building Ow"rat Oeedpu>zyq► AWdswid Cntttpllautetl�euaie _ • aprif IGOS 1•d DB968Zt •001 uoporuteuoo 104PAS 890.« Go 50 Jew £,,2'd £Sb1 6£B9L:a1 f)EbS9ZL09L 0D 83HiD?i1S:w0rJ 5£:96 6082 -90 -UW MvaurbaunaMmid RID I. "Use vebres rrttm a ferteslr6lion vrodttrl'sNFRiClorti. For fea�wioa ptadaaat wiNoyt an NFltC label, wo tit &bub volues from Section 116 of tha HaM Bf6cieaey 9tuWarLis, tt h llcd Wier; nr must be Ie" dW a eymp110 vahm from CF -IR. Iasmllcd SHCC mutt balm Omer ogoat to vnluba fiats CF-tR, or a shodinedeyies (csOQiQae pvgbaag) is iostand r� sptxlAed oe drt, CI' -11L Atmuallvsl� Iawiliod wciRlttod avttrero l�iaciore fartbe toll fontatradoo alp ire Itsa tll= ar dyaal tk ralucs*9M Cr l It. If utin: deUuh bble •SHGC valuta f-om It 16 Was* vrhadw titdod of votl • r A I, Vtt: t,ttlosiPtk vt* Nut 910 {lased above: my sV.M= )) is the 1&nWa SxcwE im prOduol iwlo "t A) is 601iv*m to or hN a Itrrltt• C•>rbetor ebd lower SHt3C *m ad spot ifi;d in the oWrl" pf om oi&am(FarmCF-1R)subvtlmodforooQtAliawrWMtbeBne►3't►Jlkwwc7&AmfaodrhrMkia"bvudkWwd 3) the pmdwt mmu q- ==do t1r0 apptWdkta negainstkm for r uftfiz asd dtvh= (fasts pat 6), wh6o vppbaWr ltem/is sipuNrc Omtd lasre14n�91maon*ie1Q (Co. Nmga) R (Irappletabk) CCeecal Coatraamr(Co-Ivlmrte)0R OWrW 4tile I OR Window Disthbow Mean !Is 5115FI furs '' Daft )swelling Sa6edntJrer�pr (Co. None) OR (if applkablc) ; tyartatd ConmaK(Co. Nttaeo) OR Owner 0R Windowltiliawibamr Flim ODIC Ituullibg $obooatraaor (C1�Nwn OR (ifopplira►bl� •Gwtarel•Cantreqtw(Co.'Nwm)0 'Ottmer OR Windota►p{ttributor Copies to; BsiGling Oqurunao, HERS Ralir ()f apOCOle) Building Ow"rat Oeedpu>zyq► AWdswid Cntttpllautetl�euaie _ • aprif IGOS 1•d DB968Zt •001 uoporuteuoo 104PAS 890.« Go 50 Jew £,,2'd £Sb1 6£B9L:a1 f)EbS9ZL09L 0D 83HiD?i1S:w0rJ 5£:96 6082 -90 -UW - ZN!STA it,ATroN c IMIM'M i or ix . CF -M Site Address Pelalit Ntmtbet OS trt5tatlatecn cauTraates (CF 6R) aremqu nd foroerb and b7 ai.y. field venfi�ttoa olid dna Y dwdlingtalut When the kattaftion of meaatres at•rtaquirr g�osttc testing ooetp the buittlla or the b;�iD 's sub atntclor shall tioamph is diagltostk: sestina end the proecderr. sPe� idIbis aerdon. What the bWlattioi: is awtjpletq the builder 16e 4tNder's subcontractor shalt aonrplcte the CF -6R (lersallation (:ettifi1WJ. acid 1101" it attha btdldit�g yte for tevitrw.br the bdalding depertrrtcnt. The builder alae shall pYowde p copy of 16t: ittstalteti0a Stela verifiittcrt tind'dt ttoatic tiesti Cita the t>LRS este lbr my rneasu>ztt requir6ia . seettm loo . WATER MATlNC3 GYM -VIS: - --�� t Ec (clone a :. : 7Yve tt a.r Rftd hwm stater 11tfr M3=&*.' .(Sobs+otos. Redmte{g tdmdal (kw w Tx* Voheee Prr E�ann.! Z Mads NKnt ef•U Qneot Blow a. K'�9' Simtthy IarWti$pn 7 3 Rwilua3 6 Rill I For smell eras storage (rated input of less ttfaa 0 aqua, to 7.$pM.. beaetrs;list .t ntYpr Factor (EP). For 1: Bim). salute rrA"'tee tnd bW "norm" waiter• . roe Ps Storage weter`bmters (rated Input ofgreater then 75.000 i3nahr), list Roeovety (RE). Thema Eflic4cY. Staff ft Lou and Rained lnptt. Fc- inner aneotq w 11ty E iicidwy and Rarod InpoL , PS atetr heaters, list Z. R-12 e>tpxrsat insubtiet is mandattpY for Slows a walla beaters wM 4M anew factor of less that 052. Kitrbeaa J'ipiag: - If itod;tatod on the CF -1 R all hot water pi b%—; 3/4 inches in diwncl r tltert tilos fit�m the hot waltzseutr�e to the kitdtda fixtures is insulated. ReuQts & Shower Heads: A II feucas and shovverheds kwWlcd wo aartifred to t1tt: Energy C7ornmission. perm to TMC 24. Pant 6. Seetioa 1111_ Central Water Heating in Bund%" with Mall4knwebagUnits (requtre0 forptescriptive) OAII hot water piping in main cinwistim loop is ittsutated to raquiremertty of 41$OQ) ❑Cenuat hot wow Systems serving sbc or fewer dwdlirg lalltt whist have (1) bis that �3'. of distribu>ion outdoors; (2) xeref distribution piping cmde�o+* (3) no teslrwaledort pip"'� that gleets the ecgaircrawas of Section 1500) MMP' sed (4) lemtmion On d+stobution pi ng ' Elowml bot water sy9ttarts trertrinr snore than a dwelling wnih - control prestatce otasatlaer a demb+o{ eoaor,* iifoeltct,�por,tta,o 1 ❑ 1. de underaigncd; •er]6 that cquiproont fasted above my 4nahro k: 1) the scow equivalent to or more 9MCit�t than that specified &the c4W sVuipetent Ina* alletJ; Z) with the F of�tplitmee(Porro Cy.,R)submitttd for cornpliaaee �&Y F$��v Maedordi far tesidertdal 61dkgs and 3) egolpntt+tt that UMM m etteceds " arquirearects for rnanurbe rued dov;cas (from theApptimrar a„�, Reagfatip or Part 6). where the ePPr'oP ub applicable: lnstalling Snbeon(Co. Nairne) Olt Contractor(Co• Name) OR Owns Cupies to: BUILDING DEPAR'fNl1J1Tf.11 EM RATEst (lir AppUCA"BUILD>Q(C OWNER AT o=PANCv /tea'1dNatto/ Conrpfiorcw Pomata _ .Vnirl.. sine 6NOV-12-2007 03:28P FROM: WINDOW SCHEDULE TO:17607777E11 P.2/6 SIZE I WINDOW I FRAME I DETAILS IREMARMSI T-24 . NO. WDM MT. TYPE OLA88 TEMP. SWC MAT. WDTM. FDRBH I ,�, amm MEAD JAMSBLL 7 1 9/D1 W6JDOW WUMBER AREA(8F) AUE VUL- Al 1 3'•0' 1 3'-0' DG I NO I wooll 7 7 .5/D1 5/DS 6/01 A 22: 49 9 0.57 A2 3'•0' 3'-0' DG NO WOOD 7 7 9/01 9/D1 10/01 A 29 9 0.57 B T-0" 5'•0' OG NO WOOD 7 7 5/D1 5/Di 6/Di C. J 21 15 0.51 C 6'-0' S'-0' DG YES W000 7 7 11/01 11/01 12/01 C 4, 59 30 0.57 0 Y-0" C-0' DG NO WOOD 7 7. 9/D1 9/Dl 10/01 C 18, s6 12 0.57 E Y-0' 3'-0' OG NO WOOD 7 7 11/01 11/D1 12/D1 C 53 9 0.57 F 2'•0' 7.0' OG YES WOOD 7 7 9/DI 9/01 10/01 V l."7.6.$0.0,44,47,54 4 0.57 G . 6'-0' 7'-6' OG NO WOOD 7 7 5/Di 5/DI 6/Dl C. J 39 46 0.57 H 4--0' 4'•6' DG YES WOOD 1 7 11/01 1VD1 12/01 C, J 18 18 0.57 J 2'-10' S'-0' DG I NO WOOD 7 7 9/D1 9/DI 10/01 C 34, 35, 40 1 14 0.57 M I 4--0 4'•6 OG 1 NO WOODI 1 1 7 1 9/D1 9/01 10/01 I C 32 18 1 0.57 N 8'-6" 6'-6' DG I NO WOODI 7 7 1 5/D1 5/01 6/DI I C, J 56 43 0.57 P 4'•0' 6'-0' DG I NO WOODI 7 7 9/DI 9/D1 Io/D1 C . 23. 44, a$. 57 24 0.57 0 3'-0' S'•6'4DG NO WOOD 7 7 9/01 9/01 t0/01 C. J 51, 6z. 17 os7 R 6'-0' 5'•0'G NO WOOD 7 7 11/01 1VD1 . 12/Dl C, J 9 30 0.57 S 6'-0' 5'-6'G NOWOOD 7 7 S/D1 S/DI 6/D1 C. J 3 33 0.67 T 4'-3' 4'-6'G NO WOOD 7 7 9/D1 9/Dt 10/D1 C 13, IS 67 0.57U 4'-0' 3'-6'G NO WOOD 7 7 9/01 9/01 10/D1 C 14 28 0.57 I A I z -b I o'•D I I 4uI NU I I WOODI 1 7' 1 7 1 9/DI 1 9/01 1 I0/DI I C 1 25 . 1 12.5 1 0.57 1 REMARKS KEYNOTER A) CIRCULAR B) SLIDING Cl CASEMENT 01 FIXED EI OUTSIDE PANELS TO BE CASEMENT FI DECORATIVE WROUGHT IRON RAILING G) SCREEN(SI H) COMPOUND ARCH AT HEAD TO FOLLOW SOFFIT JI ARCHED HEAD K) TRUE DIVIDED LITES L) BUTT JOINT MI MITERED CORNER N) TWO LITES P) THREE LITES 01 FOUR LITES RI GLASS BLOCKS SI 4 EQUAL STACKED AWNINGS; TEMPERED IF BELOW 18" AFF OR IN SAME PLANE AS DOOR T) 24' HIGH D.G. CLERESTORY ABOVE; SAME WIDTH UI WINDOW HEIGHT VARIES; TOP OF WINDOW TO FOLLOW SLOPE OF ROOF ABOVE VI AWNING WI SINGLE CENTER PANEL X) DECORATIVE WROUGHT IRON GRILLE WHERE SHOWN ON ELEVATIONS YI SEEDED GLASS Z) DECORATIVE TERRA COTTA TILE WHERE SHOWN ON ELEVATIONS AAI FIXED EXCEPT CASEMENT AT TOILET ROOM BBI PLASTER AT BOTTOM TO SLOPE THE SAME AS HEAD AND JAMBS CCI AWNING AT BOTTOM PANEL DD) FIXED - CASEMENT - FIXED EEI TEMPERED GLASS. GLASS TO BE ETCH MARKED BY MFG FFI WOOD SHUTTERS GENERAL NOTE8 11 VERIFY GLASS THICKNESS REOUIREMENTS WITH GLAZING MANUFACTURER. PROVIDE STRUCTURAL CALCULATIONS FROM MANUFACTURER AND'SUBMIT TO ARCHITECT FOR REVIEW; CALCULATIONS SWILL INDICATE CONFORMANCE WITH WIND LOAD REQUIREMENTS OF THE V.B.C. AND LOCAL AGENCIES 21 SEE EXTERIOR ELEVATIONS FOR WINDOW ELEVATIONS 31 SEE EXTERIOR ELEVATIONS FOR TRUE DIVIDED .ITE BREAK-UPS 4) SG . SINGLE GLAZING: DO . DUAL GLAZING 51 CONTRACTOR/SUBCONTRACTOR SHALL FIELD VERIFY ALL ROUGH OPENING SIZES AND MAKE APPROPNIATE REVISIONS PRIOR TO ORDERING, TYPICAL 61 ALL EXTERIOR OPENINGS SHALL BE THOROUGHLY FLASHED 71 SEE FINISH SCHEDULE THIS SHEET FOR FINISHES KEYNOTED ON WINDOW SCHEDULE 81 ALL NEW GLAZING SHALL COMPLY WITH THE S-ANOARDS OF THE U.S. CONSUMER PRODUCT SAFETY COWAISSION; MANUFACTURER TO PROVIDE CERTIFICATE OF COMPLIANCE TO OWNER 9) VERIFY MAXIMUM CASEMENT SIZES WITH SELEC-ED MANUFACTURER ' 101 ALL GLAZING TO BE CLEAR GLASS III EGRESS WINDOW SIZES AT SLEEPING AREAS TO COMPLY WITH UBC REQUIREMENTS FOR EGRESS; 44' MAXIMUM SRL; MIN. 20" CLEAR OPENING WIDTH; MIN. 5.7 SF. OPENING; KIN. 24' OPENABLE HEIGHT. EGRESS DOOR OR WINDOW SHALL BE OPENABLE FROM THE INSIDE TO PROVIDE FULL, CLEAR OPENING WIDTH WITHOUT THE.USE OF SEPARA-E TOOLS 12) WINDOW SIZES ARE APPROXIMATE SUBCONTRACTOR SHALL FIELD VERIFY ALL ROUGH OPENING SIZES NOV-12-2007 03:28P FROM: TO:17607777011 P.3/6 Certificate Of_Con aliance : Residential . (Part2 of 4) CFA R Friedrich Residence . Project Title Date 11/13/2007 _ FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments L yylndow Front 2 Window Front 061 4.0 n s7n_NERC OAS .NERC _270_ --R tWP-6200AIum1Law-E-__._ (W) 4.0 0.570 NFRC 0_45 NFRC 270 90 New IWC 6200 Alum/Low-E Whole. Mouse. Whole House 3 Window Front (W) 33.0 0.570 NFRC 0_45 NFRC 270 90 Now IWC 6200 Alum/Low-S Whole House 1 Window Rear ML 30.0 0.570 NFRC 0`45 NFRC 90 90 New IWC 6200 Alum/Low-E Whole House 5- Window Rear (gj 4.0 0.570 NFRC-0, 45 NFRC 90 90 New IWC 6200 Alum/Low-E Whole House 6 Window Right .L Window Right (S) 80.0 _ 0.570 NFRC 0.4 FRC �8g .. sQ Nay..___ WC.6200 AIumL QWE Whole House (S) 4.0 0.570 NFRC _0.45 NFRC 180 _,91)- New IWC 6200 Alum/Low-E Whole_HoUsg 8 Window Right (S) 4.0 0.570 NFRC 0.45 NFRC 180 90 New IWC 6200 Alum/Low-E Whole House 9 Window Right S) 30.0 0.570 NFRC 0.4 NFRC 180 __Q New IWC 6200 Alum/Low-E J.Q Window Right (S) 4.0 0-570 NFRC 0.45 NFRC 180 _a j law JWC 6200Alumfl-ow-E _U Window Front (S, ZO 72.0 0.570 NFRC 0.4 NERC 225 90 Now IWC 6200 Alum/Low-E Whole House Whole House Second Floor 12 Window Front (SWI. 6.0 0.570 NFRC 0;45 NFRC 225 90 New IWC 6200 Alum/Low-E Second Floor J1 Window Left 14 Window Rear (N) 57.0 0.5701JFB!'c�45 ltE� -QNOW IWC'8200 AJU -F (E) 28.0 0,570 NFRC -0-45.-NFRC 90 90 New IWC 6200 Alum/Low-E Second Fl r Second Floor 15 Window Right (SE) 57.0 0.570 NFRC 0,45 NFRC 135 90 New IWC 6200 Alum/Low-E Second Floor 16 Window Front (SW) 12.0 0,570 NFRC 0.45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 17 Window Front (SW) 64.0 0.570 NFRC 0_45 NFRC225 90 New IWC 6200 Alum/Low-E Whole House 1Q Window Front (SW) 18.0 0.570 NFRC 0,45 NFRC 225 .90 _IWC 6200 Alum/Low-E Whole House yQ Window ront IS 4.0 0.570 NFRC ,Q O NFRC 225_ _.s0_ Naw IWC 6200 Alum/Low-E 1. Indcate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. Whole House L INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC Window H9L Wd Len Over ang Left Fin Right Fin Hgl LExt RExL Dist. Len Hgt Dist Len HgL 1 Bug Screen 0.76 2.0 2.0 2,0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 _ 2.0 2.0 3 Bug Screen 0.76 5.5 6.0 2.0 0.1 2.0 2.0 T .1 Bug Screen 0.76 S.0 6.0 2.0 _01- Whole House / Exterior Mass 5 Bug Screen 0.76 2.0 2.0 2.0 01 2.0 2.0 A- Bug Screen 0.76 _,g 0 10-0 . 2.0 R -Val. Location JA IV Reference 7 Bug Screen 0.76 2.0 2.0 12.0 ..0.1 0.1 2.0 2.0 8 Bug Screen 0.76 2.0 2.0 2.0 0.1 _ 2.0 2.0 - - 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 10 Bu q Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0,76 8.0 9.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76' 3.0 2.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 . 4.3 2.00.1 _ 2.0 - 2.0 14 Bug Screen 0.76. 3.5 4.0 2.0 1 0.1 2.0 2.0 15 Bug Screen 0.76 4.5 4.3 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 ' 4.0 3.0 2.0 _0.1 2.0 2.0, 17 Bug Screen 0.76 8.0 8.0 2.0 . 0.1 2.0 2.0 - - 18 Bug Screen 0.76 4.5 4.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 .- - - THERMAL MASS FOR HIGH MASS DESIGN EnergyPro 4.3 by Energy5o6User Number; 2655 Job Number Pa e:4 of 19 Area Thick. Heat Inside Condition Location/ Type (sO (in.) Cap. Cond. R -Val JA IV Reference Status Frame Wall, Stucco 259 .0.25 21 0_47 0 09 -AS New _Comments Whole House I Exterior Mass Frame Wall, Stucco 400 0.25 21 0.47 0' 09-A5 New Whole House / Exterior Mass Frame Wall, Stucco 316 0.25 21 0_47 0 09=A5 New Whole House / Exterior Mass Frame Wall, Stucco 178 0.25 21 0_47 0 -...___ 09 -AS _ New Whole House / Exterior Mass Frame Wall, Stucco 272 0.25 21 0.47 0 09-A5 New Second Floor I Exterlor Mass PERIMETER LOSSES Insulation Condition LocatiorV Type Length R -Val. Location JA IV Reference Status. Comments Slab Perimeter 150 None No Insulation 26 -At _ _ _ New _ Whole House Slab Perimeter 210 None No Insulation 26-A1 New Whole House Slab Perimeter 150 None No Insulation 26-A1 _ _ New - Whole House EnergyPro 4.3 by Energy5o6User Number; 2655 Job Number Pa e:4 of 19 NOV-12-2007 03:29P FROM: TO:17607777311 P.4/6 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Friedrich Residence 1:1/13/2007 Project Titla _ Date ts.0 FENESTRATION SURFACES 2.0 0.1 2.0 2.0 21 True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 2Q Window Front (SWI 42 p_ 0 57A NFRC A 45 NFR .225 _M. New_mA aw•E_ _ Whnla HpUSe 21 Window Front (SWI 15.0 0.570 NFRC 0_0__45 NFRC 225 90 Now IWC 6200 Alum/Low--E Whole House �? Window Front (SWl 9.0 0.579 NFRC. 0.45 NFRC 225 9QNew IWC 6200 Alum/Low-E House 23 Window Front (SWI . 198.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-F, .__Whole Whole House 2A Window Front (SW) 24.0 0.570 NFRC 0.45 NFRC 225 90 Now IWC 6200 Alurnlow=E• Whole House $5 Window Left (NWj, 12.5 0_570 NFRC 0.4 NFRC 3150 New . fWC 6200 Mum/Low-E Whole House ^ 2 Window Left (NW)64.0 0_570 NFRC 0_45 NFRC315 _% Now IWC 6200 Alu /Low -E Whole House 27 Window Left _ NW) 20.0 0.570 NFRC 0.45 NFRC 315 90 New IWC 6200 Alumlow-E._.. Whole House 2fl Window Left (N 24-0 0_570 NFRC 0_45 NFRC 315 0 New IWC 6200 Alum /Low -E Whole House Zg Window Left .INW) 9.0 0=570 NFRC o_as NE -8t ,_ 315 _ k Now IWC 6200 AIumA ow -E Whglo Houso M Window Left ((yam 50.0 0_570 NFRC 0.4 NFRC 315 go New IWC 6200 AlumlL:ow-E Whole House 31 Window Left (NW) 64.0 0+570 NFRC 0;45 NFRC 315 90 New IWC 6200 Aluin/Low-E Whote House ,32 Window Left (NW) 190 0_570 NFRC 0.4 NFRC _315 Ne>IrlWC 6200 AIumA ow -E Whole House 33 Window Left _,qQ_ (NW) 64;0 0570 NFRC 0A NFRC 315 ,_90 New 6200 Alum/Low-E Whole House 2g Window Left _IWC (N) 14.0 0.570 NFRC 0_45 NFRC 080 New WC 6200Alumft m -E Whole Howse 35 _Window Left (N) 14.0 0_570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E 'Whole House Window Left (N) 3.0 0.570 NFRC 0.45 NFge 0 90 New IWC 6200 Alum/Low-E 'Whole House ,U _Window Left (N) 3.0 _ 0.570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low Whole House Window Left (N)_ 64.00570 NFR " 0.4s NFRC , 0 _84_ New ISc6200 ,OluM ow _ Whole ligum 1. Indicate source either from NFRC or Tebte 116A. 2. Indicate source either from NFRC or Table 1188. 4.0 INTERIOR AND EXTERIOR SHADING 2.0 0.1 2.0 2.0 # Window Overhang Left Fin Fin Exterior Shade Tye SHGC HgL Wd Len. Hgt. LE.xt. RExL Dist. Len. --Right Hat. DisL Len. Hat THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (so (in.) Cap Cond. R -Val .+..a e.-.11 u.ra ts.0 4.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 5.0 3.0 _ 2.0 0.1 2.0 2.0 22 Bug Screen ._ _ . - 0.76 3.0 3.0 2.0 0.1 2.0 2.0 - - - 23 Bug Screen T 0.76 9.0 X2.4 _ @.Q 8.0 24 25 Bus Screen Screen 0.76 8.0 3.0 ---(Ll�.!? 2.0 0.1 2.0 20 - - 26 Bus 0.76 ._5.0- EnergyPro 4.3 by EnergySofl Bun Screen 0.76 5.0 2.0 2.0 0�1 2.0 2.0 - - 27 Bug Screen 0.76 4.0 3.0 2.0 0.1 i2.0 2.0- 28 Bug Screen 0.76 2.0 1.5 15.0 0.1 15.0 15.0 29 Bun Screen0.76 3.0 3.0 2.0 0.1 2.0 2.0 30 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 31 Bug Screen 4.0 3.0 -0.76 _ 2.0 2.0 - - 32 Bug Screen 0.76 4.0 3.0 _0.1 .0 2.0 0.1 2.0 2.0- 33 Bug Screen 0.76, 6.0 4.0 2.0 _0.1 2.0 2.0 ` 34 Bug_Screen 0.76 4.0 3.0 2.0 0.1 2.0 7 2.0- 35 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 -_ - 36 Bug Scr en 0.76 4.0 3.0' 2.0 0.1 2.0 - - - 37 Bug Screen 0.76 4.0 3.0 .2.0 2.0 0.1 2.0 - 2.0- 38 Bu _9 Screen 0.76 - 8.0 - 8.0 --• 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type (so (in.) Cap Cond. R -Val JA IV Reference Condition Status LocatloN Comments Frame Wall, Stucco 443 Frame Wall, Stucco 372 0.25 21 0_47 0 0.25 21 0_47 0 09-A5 09-A5 New Second Floor / Exterior Mas& Frame Wall, Stucco 243 0,25 21 0;47 0 _ 09-A5 New New Second Floor/ Exterior Mass Second Floor Exterior Mass Frame Wall, Stucco 244 Frame Wall, Stucco ' 874 0.25 21 0.447 0 0.25 21 0_47 0 09-A5 09-A5 _ Nov Whole Hotse / Exterior Mess _ Whole Hose / Exterior Mass PERIMETER LOSSES_ Insulation Condition Location. Type Length R -Val. Location JA IV Reference Status Commerts EnergyPro 4.3 by EnergySofl Run Initiation Ttme1 11/1N0711.35,�.,... User Number. 2655 _. Run Code Job 1184982502 _ Number: - Paoe; 5 of 19 NOV-12-2007 03:30P FROM: TO:17607777011 P.5/6 Certificate Of Compliance: Residential (Part 2 of 4) CF.1 R Friedrich Residence 11/13/2007 _ Project Title Date 42 FENESTRATION SURFACES 0.76 True Cond. Location/ # Type Area LI -Factor' S_HGCZ Azm. Tilt Stat. Glazing Type Comments M Windnw I eft, fN1 45.0n1570.yFs n as NFR(% _Q- -91 Haw Or 62nn Alum/Low-F INho)e_{nuse 40 Window Rear (NE) 14.0 0.570 NFRC 0.45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 41 Window Rear (NE) 3.0 _0.570 NFRC 0 45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 42 Window Rear (NE) 41.0 0.570 NFRC 0.45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 43 Window Rear,. (NE) 198.0 0.570 NFRC 0.45.LIF$C 45 90 New IWC 6200 Low -E Alum Whole House AA Window Rem,,., -.(lam 24.0 0^570 NFRC �g5 NF- �45 � New i1hL6200 Alum/Low-E .3C / Whole House _45 Window Bear (NEI48.0 0.570 NFRC Q45 NFRC _45 C& New 6200 Alum/Low-E Whole House _JWQ _ Window Rear (NE) 4.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House AZ Window Rear (NE) 4.0 0.570 NFRC 0.4NFRC _4_,a0- tiew••--JWQ 62 -�AIL��-E Whole House g@ Wl�yy Rear(NQ ---64.0. -0.57 NFRQ -9 45 NFgc 4.9 � New IWC 6200 Alum/Low-E Whole House A9. Window Rear__,--ffl... 9.0 0.570 NERC 0.45 NFRC'90 9 New IWC 6200 AlumlLow-E Whole House 50 Window Rear (E) 48.0 0_570 NFRC 0_45 NFRC _ 90 90 New _IWC 6200 Alum/Low- Whole House .51 Window Rear tE)_ 17.0 n 57n NEBr 0_45 NERC _fQ __K_IWC 6200 Alum/Low-E Whole House _5 Window Rear .._ (!=)_ 17.0 _0_570 NFRC045 NFRC 90 90 New IWC 200 Almm/Low-E Whole House 63 Window Richt (SE) 9.0 0.570 NFRC 0_45 NERC 135 90 New IWC 6200 Alum/Low-E Whole House 4¢ 1Mndowj�lght (SE) 4.0 0.570 NFRC 0.45 NFRC 135 g0 Now IWC 6200 Alum/Low-E Whole House ^^ _ Window Right (SE) 24.0 0.570 NFRC 045 NFRr: 135 90 New IWC 6200 Alum/Low-E Whole House 5 _ Window Rloht (SE) 43.0 0 570 NFRC0 45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House .5Z Window Right (SE) 24.0 0.570 NFRC 0.45 _NFRC 135 _& New lWC 6200 Alum/Low-E �Whole House 1. Indicate Source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. Bug Screen INTERIOR AND EXTERIOR SHADING 2.0- Window. Overhang Left Fin # Right Fin _ Exterior Shade Type SHGC _ Hgt. Wd, Len._ Mgt. LExt. RExt. Dist: Len. Hat. DlsL Len. Hot 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 %4 13ug Screen - _ 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 46 Bun Screen .. 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0,76 52 Bug Screen _ 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0,76 56 Bug Screen 0.76 57 Bug Screen 0.76 8.0 _60 2.0_0.1 2.0 2.0 4.0 3.0 2.0 0.1 • 2.0 _ 2.6 ` 4.0 _3_0 2.0 0.1 2.0' 2.0 4.0 3.0 IQ o.t 2.0 2.0 90 _ 01 200 -19-0 - 6.0 _4.0 _2.4 _QJ _ --a. 8.0 6 0 2.00 1 2,0 2.0 2:0 2.0 2.0 0.1 2.0 2.0 4.0 3.0 2.0 0.1 2.0 2.0- 6.0 9.0 2.0 0.1 2.0 2.0- 3.0 3.0 2.0 0.1 2.0 2.0 - 8.0 6.0 3.0 0.1 2.0 2.0 5.8 3.0 2.0 0.1 2.0 2.0 5.8 3.0 2.0 0.1 2.0 2.0 3.0 3.0 2.0 0.1 2.0 .2.0- 2.0 2.0 2.0 0.1 2.0 2.0- 8.0 3.0 15.0 0.1 15.0 15.0 ` 8.0 5.0 15.0 0.1 15.0 15.0-"- 8.0 3.0 2.0 0.1 2.0 2.0 0 0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Type. Condition Location/ (so Jin.) Cap. Cond. R -Val. JA IV Reference Status Comments Frame Wall, Stucco F 157 0.25 21 0.47 0 . 09-A5 New Whole House! Exterior Mass Frame Wall. Stucco _ 600 0.25 21 0 09-A5 _ A047 Frame Wall, Stucco 854 0.25 21 0_47 0 09 A5 _ New Whole House / Exterior Mass New Whole House / Exterior Mass PERIMETER LOSSES Insulation Locatioru Condition Type Length R -Val, Location JA IV Reference Status Commerts Rum Initiation Time .11113107 1 :35oQ2 Run Codei _1194982502 EnargyPro 4.3 by EnergySolt' User Number:. 2855 _ Job Number: _ _ Page:6 of 19 NOU-12-2007 03:30P FROM: TO:17607777011 . P.6/6 Certificate Of Compliance:. Residential (Part 2 -of 4) CF -1 R Friedrich Residence _ Project Title Date 11/13/2007 FENESTRATION SURFACES True Cond. # Type ` Area U -Factors SHGC' Am. Tilt Stat. Glazing Type Location/ Comments Sfl-WMd0W—R1oht—(SE) _3211 _052DWERC-045 .NFRC ._ 135_ 00. dew 041j162-Alurollaw-E 59 Window Right (SE) 30.0 0.570 NFRC 0.45 NFRC 135 90 New IWC 6200 Alum/Low-E Who laklouss---.. _... ------ Whole House 1. Indicate source ellher from NFRC or Table 116A 2. Indicate source eater from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin # Exterior Shade Type SHGCHOt. Wd. Len. Hgt. LEA. REA Dist, Len. Right Fin Hgt. Dist Len: Hgt. 58 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 59 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 _ THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Locatiord Type (sf) (in.) Cap. Cond. R -Val JA IV Reference Status Comments PERIMETER LOSSES InsulationCondition Location;' Type Length R -Val. Location _ JA IV Reference Status Commerts Run Initiation Time: 1111LO1 11;35:02 Run Code:.A194982502 _ EnergyPro 4.3 by Enewson User Number. 2655 .lob Numbor: pogo.? or 19 09-19-09 12:50PM FROM-GOUVIS ENGINEERING 949 752 5311 T-049 P.001/001 F-556 h UV.44 - Y• Y- _ . • • --• Wo� u inc. consulting bro p� August 18, 2008 1hr09 Kris Friedrich Kris & Marilee Friedrich 5 Mirada Circle Rancho Mirage, CA 92270 Re: Friedrich ResidenceoeA C,4 GECG Job # 61689 Custom Dear Mr. Friedrich, This letter advises that we have observed the structural requirements that are visible during construction at the time of our site visit. our visit Gouvis Engineering believes that tcoriformailnce with uoui�struct cal plan at the time ns and relevant items noted on field notes) is i 9 correspondence issued by our office relating to the above referenced dwelling. II and; stucco. We We observed the building in its framed ctural condition prior requirements. installation sae items such as: size observed the visual and athelfoutru ndationsndroof sheathing.) of footings, reinforced steel This report is uich is nderstood to be an information and bel efs.sAs opinion t consist i of agrine eport for ed or based on his best knowledge, info structural elements (as above outlined) and is neither a guarantee nor a warranty, express implied for other trades or requirements of subject dwelling. s Respectfully Submitted. " GOUVIS ENGINEERING CONSULTING GROUP, INC. Basil A Ammari, P.E. Director of Field Operations . PRQF y �CALIFOPN`P / 949.752.1612 fax ::,i �'Y�F' •;�:;•� 752.5321 '':r: , .r, :"e:�::.5°•; 4400 Campus Drive Newport Beach, CA Ho Chi Minh City, Vi 92660 Las Vegas, NV Palm Springs, CA Pleasanton, CA Sacramento, CA etnam T -OA 01:OTPM FROM-GOUVIS ENGINEERING 949 752 5321 T-841 P.007/010 F-130 .�. ' • - • �� row. - - `� � � loow.�. - ski I►PIM - -/ Game - RA Si ( T eL • ' - = Sea + rhe"!fS Ho K . 01-G'-08 A11R 01:O1PM FROWCOUVIS ENGINEERING 949 152 5321 7-841 P.•001/010 F-130 SO consulting group, ina .... .�_ ate• FAX TRANSMITTAL Compw.. Strother Conmucdon Co!!e!y . Auendom Dennis Date: July 16, 2W8 Job Nw 61689 ---- WA No.: 316 Job Name: Friedrich Residmce remw 760-398-3453 PagesIO Onduft Cow Me) REMARKS —_�:i�C--�—lOtIT.J(JTllO•'AaT1aCY.+1 .aii�`t•J%1L147aw J.1 .T•aI '.J �T,' i� . Per your request, please fmd enclosed fvm and darifitation for.the items brought up during framing walk by Basil Ammari. If you have any questions or comments, please do not hesitate to contact " office. Thanks. COPY TO Basil Ammari Q Gouvis Engineering Group of Companies - - -- _ From: Amir DeihhW Project Manager //endowres are pores noasd please inform us immed�rey. 949.752.1612 Fax 949.752.5321 4400 Campus Drive Ncwport Beach, CA 92660 Las Vcgas, NV Palm Springs, CA Pleasanton, CA Sacramento. Co Ho Chi Mitch City OT -17-09 01:OTPM FRO*-GOUVIS ENGINEERING 949 T52 5321 T-941 P.002/010 F=130 • VWX C"VIM-- �{ i►-- 760- 39S --3q5-3 ! i A1XiiO�d��7i�er o weea...aR . Lo o weea...aR . 07-1�-OB 01:07PM FRO*-GOWIS ENGINEERING M t kt 5A561 - ye sier, day Q Q7 yOgr 948 782 5321 T-841 3.003/010 F-130 7-x'08 d fd our :SrrucTu rrJ toM K 7-( And hsKE D M6 TO o-pprovAL OA A FCW TIS niS, w1r i4A'v E' PrA w hem c A tI S - �ov- - - Ar BATH 5 AboOFI tic i le+- Will +h1s be sif'icte4 OK C21 WE i nsTA Ileo The BEAMS DtFFCrek%+ ikaK -t-ka p(&v% AT t�A"- Oc.[Midle gaas'r kooK. s6L= .4#,4c-/4ed d nxwt kq , nk D3J AT HALL TO OEDrOGM L{ WE A ddc0 A double z.Ajc> a.rweev rhe a-ldge-..4njd the AT 3 1z,)cA-rioKS • SEE A* -4c -ked Q xWi1R oK- Nut C,*Ij W6 A 3S BEAR ) o Pos i go -+k Sides A 6 o V 6 F�;d-ev- TO%le-i'. SGC Af!Ackad Dft. W;V%l �'nm w4 y.%,(. u.Irw ;am wl (Z) Os s �1VA35 rsA- to&) i'' UWA, 24oN1 aWA.II CAPS F'or S'sheav- WAR AIUO ACTU Al iS 3'3°' Bec.AuSC d' A Pbc-K-e-+ t, w. uJrL[- (o. ALL MASan ry POreplac,esC W6ac Ck&Med +0 15 a Icer YL, OK OT-t.T-08 01:OTPM FRO*GOWIS ENGINEERING ,s-X'sm !co, 4�,6 W IOZ x 949 752 5321 Nj rJ 8 ax10 T-841 P.004/010 F-130 v 1 3ypx T�-'01- a.- x 01L xx ca 3: x 13 %.. 6,&a O7 -1i-08 01:OTPM FROWGOUVIS ENGINEERING i�Olf'�i�I? oo� 949 752 5321 T-841 P-005/010 F-130 'ix& PS4 o*V /elf 70-1' OT -1T-08 01 :OTFM FROM-GOUVIS ENGINEERING 940 T52 $321 T-941 P-006/010 F-130 S - HEET.S -11B JOB NO- 61689 GaUVISK PLAN: ���ng gromA inc- DATE 07/ 16/08 CUENT. LOW HI A* kAl I = us Rig X :4b W- ED 2'-0" F.H. I ;k OT -,l T-08 01:08PM FROM-GOWIS ENGINEERING 949 T52 5321 T-841 P.008/010 F-130 VV %.,, 3 h um z J;L U 03 f xy T r 0. I 6' �+ 00 o@ VR<Z Z*4� fto n 06i -d 010/010'd 108-1 1299 Z91 868 9N1833N19N3 SIAI109- l Wd80:10 80-11-10 061-d 010/800'd Itis -1 1262 251 Ste ON1833NISN3 SIAnOD-H08d NId90:10 80-11-10 0 � r � G i ON1833NISN3 SIAnOD-H08d NId90:10 80-11-10 OT -I2-08 05:11TOM FR OWGWVIS ENGINEERING 249 T52 5321 T -ITT P-001/003 ;-202 nl '*A consulting group, inc. FAX TRANSMITTAL Coff WaW. Scrodw Construction L.*Mpm Dao c July 22_2 job No.: 61689 W.JL No.: 317 Acentlarc Dennis job Name: Friedrich Residence Tekfw 760-398-3453 PAW '.L (Induft Cover PM4 REMARKS Furstwt to your request for information reprding the above captioned projem we submit dw following The attached detail Is sawcuirally acceptable for plywood at ceft-aic mases bedroon G41i COPY TO v Basil Amma6 @ Gouvis Engineering Group of Companies From: Amir Deihimi Project Manager ffendawres are not as noted please inform to immedbasio: 949,752.1612 Fax 949.752.5321 4400 Campus Drive Newport Beach. CA 92660 Las Vegas. NV Palm Springs, CA Pleasanton, CA Sacramento, CA Ho Chi M= City v OT -Y2-08 05:OTPM FROIA'SOUVIS ENGINEERING 0-0 MIR SHIA)KIT r. 949 T52 5321 T4TT P.002/003 F-202 SWAMMURUCt I t 111f o tNC. � 1 M�1AQAdRCIE RPM= MK4MCA =70 i 7W770 -5M li�T8077a5430 FAXTSD%gC-NMJOBTMBW Tomom r -ax - -7(** 3 53 z•j'd ROM 06iO1 SMA m TFi lnMlR:wo+i wa acp-;P--nr s uV RedJgr amp at�l9lon:AM IF, - —a z -919 " t- - • oAc. loo": D FbtyOurbf�naU� Tomom r -ax - -7(** 3 53 z•j'd ROM 06iO1 SMA m TFi lnMlR:wo+i wa acp-;P--nr s 4 RedJgr amp U PNSM�con�IMent C� PYe�teyien D FbtyOurbf�naU� Tomom r -ax - -7(** 3 53 z•j'd ROM 06iO1 SMA m TFi lnMlR:wo+i wa acp-;P--nr s OT -22-08 Q . 05:OTPM FROWGOWIS ENGINEERING `N A 8r�/, .9!- 949 752 5321 T -STT P.003/003 F-202 .ft 10itcS ?ip.•A ZpF. vrbA*1eI apirga)J04) 171 WA 1nw1CsWoad c7• ar _ia��nr TITLE 24 REPORT Title 24 Report fo Friedrich ResidencE Lot 6a La Quinta, Ca CITY OF LA QUINTq BUILDING & SAF A P P R® E DEPT ; FOR CONSTRUCTION DATE1V ` 0 B Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, .CA 92211 (760) 779-0657 Job Number: Date: 10/11/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 OCT 2 2 2007 D BY TITLE 24 REPORT Title 24 Report fo Friedrich ResidencE Lot 6a La Quinta, Ca CITY OF LA QUINTq BUILDING & SAF A P P R® E DEPT ; FOR CONSTRUCTION DATE1V ` 0 B Project Designer: Report Prepared By: Joan D. Hacker Insu-form, Inc. 41-921 Beacon Hill, Suite A Palm Desert, .CA 92211 (760) 779-0657 Job Number: Date: 10/11/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Form ECON-1 Energy Use and Cost Summary 1 2 3 10 12 13 16 19 EnergyPro 4.3 by EnergySoft Job Number: User Number: 2655 6 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R FripdriChResidenre Project Title 10/11/2007 Date Iot6a I a Qllinta Project Address Building Permit # In-,ii-fDLm Inc_ (760) 779-0657 Documentation Author Telephone planCheck/Date FPrPrc) Compli ce Method 151 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.13 3.45 -1.31 Space Cooling 59.88 56.46 3.42 Fans 8.50 9.50 -1.01 Domestic Hot Water 2.95 3.80 -0.86 Pumps 0.00 0.00 0.00 Totals 73.46 73.21 0.25 Percent better than Standard: 0.3% Building Type: (J Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (SW) 225 deg Natural Gas Area: 2,006 ft2 Avg. U: Ratio: 24.5% Avg. SHGC: BUILDING ZONE INFORMATION Zone Name 0.57 0.45 Floor Area Volume OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Wall wood 259 n D74 R-19 R_n n 27n An Wall Wood 400 n_o7a R_19 R-0.0 X15 An Wall Wnnd 316 n n74 R_19 R-0 0 gn An Wall— Wnnd 17R n 074 R_19 R -n n 1Rn An Rnof Wood 1 428 _n 025_ R_39 R-0_0 45 n Wall Wnnd 272 n 074 R_19 R_n n 925 9Q Wall Wnnd 443 n n74 R-19 R -n n d gp Wall Wnnd 372 n 074 R-19 R -n n A() M Wall Wood 243 0 074 R_19 R-0 0 135 9Q Rnof Wnnd 422 Q025_ R_18 R_n n 45 Wall Wood 199 n 074 R_19 R -n n 225 AII Wall Wond 887 0074 R_19_ R_0 n 315 AQ Wall Wood 60 0 074 R_19 R-0 n n gn Wall Wnod 576 0.074 R-19 R-0.0 45 An Wall Wood 51 0 074 R_19 R-0 0 gn go Wall Wond 857 n 074 R_19 R -n n 135 An Rnnf Wnnd 5924 0025 R_38 R-0 0 45 0 Total Conditioned Floor Area Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Number of Stories: # of Units Zone Type Conditioned Conditioned Conditioned Thermostat Type Setback— Sethack Setback 8,196 ft2 n/a ft2 0 ft2 7,774 ft2 10.0 ft 1.00 2 Vent Hgt. Area S —n/n 8 n/a 8 n/a Gains Condition Y / N Status JA IV Reference Location / Comments L_ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Paae:3 of 19 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Friedrich Residence 10/11/2007 Project Title Date FENESTRATION SURFACES # Type Area U-Factorl SHGCZ True Cond. Am. Tilt Stat. Glazing Type Location/ Comments 1 Window Front (W) 40_ QS7 NFRC 04 NFR • 97n _9Q New IWC 6900 Alum/1 ow -E (,uest House 2 Window Front (W) 4.0 0.570 NFRC 0.45 NFRC 270 90 New IWC 6200 Alum/Low-E Guest House 3 Window Front (W) 33.0 0.570 NFRC 0_45 NFRC 270 90 New IWC 6200 Alum/Low-E Guest House 4 Window Rear (E) 30.0 0.570 NFRC 0.45 NFRC 90 90 New IWC 6200 Alum/Low-E Guest House 5 Window Rear (E) 4.0 0.570 NFRC 0.45 NFRC 90 90 New IWC 6200 Alum/Low-E Guest House 6 Window Right (S) 80.0 0_570 NFRC 0_45 NFRC 180 90 New IWC 6200 Alum/Low-E Guest House L Window Right (S) 4.0 0=570 NFRC 0_45 NFRC 180 90 New IWC 6200 Alum/Low-E Guest House 8 Window Right (S) 4.0 0.570 NFRC 0.45 NFRC 180 90 New IWC 6200 Alum/Low-E Guest House 3 Window Right (S) 30.0 0=570 NFRC 00.45 NFRC 180 90 New IWC 6200 Alum/Low-E Guest House -M Window Right (S) 4.0 0=570 NFRC 0_45 , NFRC 180 90 New IWC 6200 Alum/Low-E Guest House " Window Front (SW) 72.0 0_570 NFRC0 45 NFRC 225 90 New IWC 6200 Alum/Low-E Second Floor 12 Window Front (SW) 6.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Second Floor 13_ Window Left (N) 57.0 0_570 NFRC 0_45 NFRC 0 qQ_ New IWC 6200 Alum/Low-E Second Floor 14 Window Rear (E) 28.0 0.570 NFRC 0_45 NFRC 90 90 New IWC 6200 Alum/Low-E Second Floor 15 Window Right (SE) 57.0 0.570 NFRC 0_45 NFRC 135 90 New IWC 6200 Alum/Low-E Second Floor 16 Window Front (SW) 12.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 17 Window Front (SW) 64.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 18 Window Front (SW) 18.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 19_ Window Front (SW) 4.0 0_570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. 0.76 INTERIOR AND EXTERIOR SHADING Area Thick. Heat (sf) (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments Frame Wall, Stucco 259 0.25 21 0_47 0 Window New Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.5 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 5.0 6.0 2.0 0� 9 9.0 5 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 8.0 10.0 2.0 _0. 2o go 7 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 8.0 9.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 4.0 4.3 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 3.5 4.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 4.5 4.3 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 17 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 4.5 4.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat (sf) (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments Frame Wall, Stucco 259 0.25 21 0_47 0 09-A5 New Guest House / Exterior Mass Frame Wall, Stucco 400 0.25 21 0_47 0 09-A5 New Guest House / Exterior Mass Frame Wall, Stucco 316 0.25 21 0_47 0 09-A5 New Guest House / Exterior Mass Frame Wall, Stucco 178 0.25 21 0_47 0 09-A5 New Guest House / Exterior Mass Frame Wall, Stucco 272 0.25 21 0_47 0 09-A5 New Second Floor / Exterior Mass PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 150 None No Insulation 26-A1 New Guest House Slab Perimeter 210 None No Insulation 26-A1 New Whole House Slab Perimeter 150 None No Insulation 26-A1 New Whole House Run Initiation Time: 10/11/07 14:18:04 Run Code: 1192137484 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:4 of 19 'Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Friedrich Residence Inside Cond. R -Val. 10/11/2007 Project Title Location/ Comments Date 443 FENESTRATION SURFACES 0_47 0 09-A5 New Second Floor / Exterior Mass Frame Wall, Stucco True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 211 Window Front (SW) _32 Q -0 570 NFRC Q45 NFRC _225_ _90_ New IWC 62nn Ahem/Low-F Whole House 21 Window Front (SW) 15.0 0.570 NFRC 0.45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 22 Window Front (SW) 9.0 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 23 Window Front (SW) 121.5 0.570 NFRC 0.45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 24 Window Front (SW) 121.5 0.570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 25 Window Front (SW) 24.0 0_570 NFRC 0_45 NFRC 225 90 New IWC 6200 Alum/Low-E Whole House 2fi Window Left (NW) 64.0 0.57 NFRC 0_45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House 27 Window Left (NW) 20.0 0.570 NFRC 0.45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House 2$ Window Left (NW) 24.0 0_570 NFRC 0_45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House 2-q Window Left (fes 9.0 0_570 NFRC J14-5 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House ,3Q Window Left (NW) 50.0 0_570 NFRC 0_45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House 31 Window Left (NW) 64.0 0.570 NFRC, 0_45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House -32- Window Left (NW) 18.0 0_570 NFRC )_45 NFRC 315 -9Q New IWC 6200 Alum/Low-E Whole House 33 Window Left (NW) 64.0 0.570 NFRC 0_45 NFRC 315 90 New IWC 6200 Alum/Low-E Whole House 34 Window Left (N) 14.0 0.570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 35 Window Left (N) 14.0 0.570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 36 Window Left (N) 3.0 0.570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 37 Window Left (N) 3.0 0.570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House I$ Window Left (N) 64.0 0=570 NFRC 0_45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 9.0 13.5 8.0 0. 8.0 _8.0 24 Bug Screen 0.76 9.0 13.5 8.0 0.1 8.0 8.0 25 Bug Screen 0.76 8.0 3.0 2.0 0, 2.0 2.0 26 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 28 Bug Screen 0.76 2.0 1.5 15.0 0.1 15.0 15.0 29 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 30 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 31 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 32 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 33 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 34 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 35 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 36 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 37 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 38 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat (sf) (in.) Cap. Inside Cond. R -Val. JA IV Reference Condition Status Location/ Comments Frame Wall, Stucco 443 0.25 21 0_47 0 09-A5 New Second Floor / Exterior Mass Frame Wall, Stucco 372 0.25 21 0_47 0 09-A5 New Second Floor/ Exterior Mass Frame Wall, Stucco 243 0.25 21 0_47 0 09-A5 New Second Floor / Exterior Mass Frame Wall, Stucco 199 0.25 21 0_47 0 09-A5 New Whole House / Exterior Mass Frame Wall, Stucco 887 0.25 21 0_47 0 09-A5 New Whole House / Exterior Mass PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 10/11/07 14.18.04 Run Code: 1192137484 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:5 of 19 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Friedrich Residence 10/11/2007 Project Title Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments 39. 40 Window Window Left Left (N) (N) 9 0 0 570 NERC 0_45 NERC (_ -91 New IWC 6200 Alum/1 nw-F 48.0 0.570 NFRC 0.45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole Hnuse Whole House 41 Window Left (N) 72.0 0.570 NFRC 0.45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 42 Window Left (N) 12.5 0.570 NFRC 0.45 NFRC 0 90 New IWC 6200 Alum/Low-E Whole House 43 Window Rear (NE) 14.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 44 Window Rear (NE) 3.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 45 Window Rear (NE) 41.0 0=570 NFRC 00.45 NFRC _ 45 90 New IWC 6200 Alum/Low-E Whole House 46 Window Rear (NE) 198.0 0.570 NFRC 0.45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 4Z Window Rear (NE) 24.0 0.570 NFRC 0_45 NFRC _45 90 New IWC 6200 Alum/Low-E Whole House 4$ Window Rear (NE) 48.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House A9 Window Rear (NE) 4.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 50 Window Rear (NE) 4.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House _51 Window Rear (NE) 64.0 0 570 NFRC 0_45 NFRC _45_ qn New IWC 6200 Alum/Low-E Whole House 52 Window Rear (NE) 24.0 0.570 NFRC 0_45 NFRC 45 90 New IWC 6200 Alum/Low-E Whole House 53 Window Rear (E) 17.0 0.570 NFRC 0_45 NFRC 90 90 New IWC 6200 Alum/Low-E Whole House 54 Window Rear (E) 17.0 0.570 NFRC 0_45 NFRC 90 90 New IWC 6200 Alum/Low-E Whole House 55 Window Rear (E) 15.0 0.570 NFRC 0_45 NFRC 90 90 New IWC 6200 Alum/Low-E Whole House 56 Window Right (SE) 9.0 0.570 NFRC 0_45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House 5Z _Window Right (SE) 4.0 0.570 NFRC 0_45 NFRC 135 90 New 1_WC 6200 Alum/Low-E Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. 2.0 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 41 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 42 Bug Screen 0.76 5.0 2.5 2.0 0- 2.0 2.0 43 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.02.0 44 Bug Screen 0.76 4.0 3.0 2.0 0� 9 Q 2.0 45 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 46 Bug Screen 0.76 9.0 22.0 20.0 0.1 20.0 20.0 47 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 48 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 49 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 50 Bug Screen 0.76 4.0 3.0 2.0 0.1 2.0 2.0 51 Bug Screen 0.76 8.0 8.0 2.0 0.1 2.0 2.0 52 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 53 Bug Screen 0.76 5.8 3.0 2.0 0.1 2.0 2.0 54 Bug Screen 0.76 5.8 3.0 2.0 0.1 2.0 2.0 55 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 56 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 57 Bug Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Frame Wall, Stucco 60 0.25 21 0_47 0 09-A5 New Whole House / Exterior Mass Frame Wall, Stucco 576 0.25 21 0_47 0 09-A5 New Whole House / Exterior Mass Frame Wall, Stucco 857 0.25 21 0_47 0 09-A5 New Whole House / Exterior Mass PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 10/11/07 14:18:04 Run Code: 1192137484 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:6 of 19 Certificate Of Compliance: Residential (Part2 & 4) CFA R Friedrich Residence 10/11/2007 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Exterior Shade Type SHGC Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments .5a Window Right (RE) 240 0_570 NFRC 0_45 NERC: 135 qO_ New IWC X200 Alum/I ow -F WhoIP House 59 Window Right (SE) 40.0 0.570 NFRC 0.45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House 60 Window Right (SE) 24.0 0.570 NFRC 0_45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House 61 Window Right (SE) 12.0 0.570 NFRC 0.45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House 62 Window Right (SE) 30.0 0.570 NFRC 0_45 NFRC 135 90 New IWC 6200 Alum/Low-E Whole House 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen 0.76 8.0 3.0 15.0 0.1 15.0 15.0 59 Bug Screen 0.76 8.0 5.0 15.0 0.1 15.0 15.0 60 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 61 Bug Screen 0.76 4.0 3.0 2.0 0.1 9.0 2.0 62 Bug Screen 0.76 5.0 6.0 2.0 0.1 2 0 2.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Len Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Run Initiation Time: 10/11/07 14.18.04 Run Code: 1192137484 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:7 of 19 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Friedrich Residence 10/11/2007 Project Title Date HVAC SYSTEMS Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford -White Corp. Small Gas No Pipe Insulation 2 70,000 75 New 0.59 n/a n/a �R273T���CXT(T Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name Title/Firm: Address: Telephon : Lic. #: ( (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: 760 779-0657 n. SOLI (sign r) (date) STAMP Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Guest House Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Second Floor Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback Whole House Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Guest House Ducted Ducted Attic 4.2 New Yes Second Floor Ducted Ducted Outdoors 4.2 New Yes Whole House Ducted Ducted Outdoors 4.2 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford -White Corp. Small Gas No Pipe Insulation 2 70,000 75 New 0.59 n/a n/a �R273T���CXT(T Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name Title/Firm: Address: Telephon : Lic. #: ( (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: Joan D. Hacker Title/Firm: Insu-form, Inc. Address: 41-921 Beacon Hill, Suite A Palm Desert, CA 92211 Telephone: 760 779-0657 n. SOLI (sign r) (date) STAMP Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Friedrich Residence 10/11/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R installation certificate. IPlan I Field The HVAC System "Guest House" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Guest House" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38ETG04230" includes credit for a 11.7 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Second Floor" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Second Floor" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38ETG04230" includes credit for a 11.7 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System "Whole House" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "Whole House" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 38ETG06030" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Paae:9 of 19 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ *§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑x ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ *§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El N ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page: 10 of 19 Mandatory Measures Summarv: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ X❑ ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements ❑ ❑ ❑ of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. ❑ ❑ ❑ 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause Page: 11 of 19 reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ❑ ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ❑ ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ X❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ X❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ X❑ ❑ controlled by an occupant sensor that complies with Section 1'19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page: 11 of 19 Residential Kitchen Lighting Worksheet WS -5R Friedrich Residence 10/11/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 40w Lng Cmpt T5 Fluorescent Twin Yes X No 43.0 x 14 = 602 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or YesNo x = or Yes No x = or Yes No x = or Yes No x = or Total A: 602 B: 0 COMPLIES IF A'>- B YES ® NO ❑ E 3 EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Paae:12 of 19 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Friedrich Residence 10/11/2007 SYSTEM NAME FLOOR AREA Guest House 1,428 IGINEERIN Number of Systems 1 Heating System Output per System 74,000 Total Output (Btuh) 74,000 Output (Btuh/sgft) 51.8 Cooling System Output per System 42,000 Total Output (Btuh) 42,000 Total Output (Tons) 3.5 Total Output (Btuh/sgft) 29.4 Total Output (sgft/Ton) 408.0 Air System CFM per System 1,395 Airflow (cfm) 1,395 Airflow (cfm/sqft) 0.98 Airflow (cfm/Ton) 398.6 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions EATING SYSTEM PSYCHROME 26.0 of 68.9 of Outside Air 0 cfm Supply Fan 1395 cfm 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,044 18,537 2,382 413 20,983 0 1,939 1,599 0 0 0 0 0 0 0 0 0 1,939 1,599 22,4151 2 382 24 181 Carrier 38ETGO4230 28,651 9,502 74,000 Total Adjusted System Output28,651 9,502 7x,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 'earn Temperatures at Time of Heatina Peak) 68.9 of S 118.80F Heating Coil K Return Air Ducts 4 Supply Air Ducts 117.7 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.6 OF 79.3/66.0 OF 79.3/66.0 OF 60.0/58.9 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 61.3 / 59.4 of 1395 cfm 52.1% R.H. ROOMS 79.3/66.0 of 78.0 / 65.6 of Return Air Ducts I I EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page: 13 of 19 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Friedrich Residence 10/11/2007 SYSTEM NAME FLOOR AREA Second Floor 422 Number of Systems 1 Heating System Output per System 74,000 Total Output (Btuh) 74,000 Output (Btuh/sgft) 175.4 Cooling System Output per System 42,000 Total Output (Btuh) 42,000 Total Output (Tons) 3.5 Total Output (Btuh/sqft) 99.5 Total Output (sgft/Ton) 120.6 Air System CFM per System 1,395 Airflow (cfm) 1,395 Airflow (cfm/sgft) 3.31 Airflow (cfmlTon) 398.6 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,092 19,810 1,268 233 12,056 0 2,072 919 0 0 0 0 0 0 0 0 0 2,072 919 23 954 1 268 13 893 Carrier 38ETG04230 29,459 8,376 74,000 Total Adjusted System Output 29,459 8,376 74,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.4 OF 69.40 119.2 OF O Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 118.6 °F fill 1395 cfm ROOMS 69.4 OF 70.0 OF o..a. .... A:. n.._a_ U49 I POOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) I 11.0 / 77.6 OF Outside Air 0 cfm 79.4 / 65.5 OF 79.4/65.5 79.4 / 65.5 OF 59.6 / 58.4 OF Supply Fan 1395 cfm Cooling Coil A:_ r%.._a. Supply Air Ducts 60.9 / 58.9 of 50.3°% R.H. ROOMS 78.0/65.0°F EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page: 14 of 19 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Friedrich Residence 10/11/2007 SYSTEM NAME FLOOR AREA Whole House 6,346 Number of Systems a Heating System Output per System 70,000 Total Output (Btuh) 280,000 Output (Btuh/sgft) 44.1 Cooling System Output per System 56,000 Total Output (Btuh) 224,000 Total Output (Tons) 18.7 Total Output (Btuh/sqft) 35.3 Total Output (sgft/Ton) 340.0 Air System CFM per System 2,055 Airflow (cfm) 8,220 Airflow (cfm/sgft) 1.30 Airflow (cfm/Ton) 440.4 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airs 26.0 OF 69.2 OF 69.2 OF 40 ' 1114 Outside Air 0 0 cfm 69.2 OF 11.0 / 77.6 OF Outside Air 0 cfm 79.1/67.8 °F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent 1, CFM I Sensible 6,560 94,503 7,830 2,867 92,726 0 9,885 7,065 0 0 0 0 0 0 0 0 0 9,885 7,065 114,72773F777;30 Carrier 38ETGO6030 138,181 71,370 Total Adjusted System Output 138,181 71,370 (Adjusted for Peak Design Conditions) 101.2 OF Supply Fan Heating Coil 8220 cfm HROMETRICS (Airstream 79.1 / 67.8 OF 0 TIME OF SYSTEM PEAK I Aug 2 pm �% Return Air Ducts 11 79.1 / 67.8 OF . 63.3 / 62.4 OF Supply Fan Cooling Coil 8220 cfm h Return Air Ducts 'I 106 857 280,000 280,000 Jan 12 am Supply Air Ducts 100.4 OF ROOMS 70.0 OF Supply Air Ducts 64.5/62.8OF 58.4°, R.H. ROOMS 78.0 167.4 OF EnergyPro 4.3 by EnergySoft User Number: 2655 Job Number: Page:15 of 19 ]ROOM LOAD SUMMARY PROJECT NAME Friedrich Residence DATE 10/11/2007 SYSTEM NAME Guest House FLOOR AREA 1,428 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Guest House 1 1,044 18,537 2,382 1,044 18,537 2,382 413 20,983 PAGE TOTAL TOTAL 1 1,044 18,537 21382 413 20,983 1 1,044 18,537 2,382 413 20,983 EnergyPro By EnergySoft User Number: User Job Number: Page: 16 of 19 ROOM LOAD SUMMARY PROJECT NAME Friedrich Residence DATE 10/11/2007 SYSTEM NAME Second Floor FLOOR AREA 422 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Second Floor Second Floor 1 1,092 19,810 1,268 1,092 19,810 1,268 233 12,056 PAGE TOTAL 1 1,092 19,810 1,268 233 12,056 TOTAL 1 1,092 19,810 1,268 233 12,056 EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 19 ROOM LOAD SUMMARY -71 PROJECT NAME DATE Friedrich Residence 10/11/2007 SYSTEM NAME FLOOR AREA Whole House 6,346 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM I SENSIBLE Whole House Whole House 1 6,560 94,503 7,830 6,560 94,503 7,830 2,867 92,726 PAGE TOTAL 1 6,560 94,503 7,830 2,867 1 92,726 TOTAL 1 6,560 94,503 7,830 2,867 92,726 EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 19